Vous êtes sur la page 1sur 356

The Righ

t Choice!
Applicable. Available. Accountable.

Himel is:

APPLICABLE
AVAILABLE
ACCOUNTABLE
ABOUT US

imel is an international manufacturer and provider

of low-voltage electrical products that successfully

combines global expertise with local knowledge.

We focus on true partnership with customers and


offer products that meet practical needs and ensure
relevant compatibility for common usage. We work to
be always ready for our customers and react quickly
to their needs. We are accountable and committed to
maintaining sustainable, long-term relationships.
At Himel we believe that functionality and availability
do not have to come at a high cost. We ensure that our
simple and solid products are always where they are
needed. We guarantee complete originality of all our
components and promote safe installation and usage.

Reliable Quality

For more details, please contact your local Himel Distributor .

Final Distribution

002-062

Miniature Circuit Breaker & Switch Disconnectors

002

Residual Current Devices

030

Accessories for MCB & RCCB

046

Control Devices

051

Surge Protective Device

056

Distribution Box

058

Low-voltage Distribution

063-193

Molded Case Circuit Breaker

036

Air Circuit Breaker

120

Motor Control & Protection

194-266

Contactor&Thermal Overload Relay

194

Capacitor Switching Contactor

246

Relay

248

Motor Protector

258

Magnetic Starter

265

Power Energy Management

267-294

Current Transformer

267

Meter

271

Digital Time Switch

284

Voltage Stabilizer

288

Industrial Control Components

295-339

Control Signal

295

Fuse

321

Industrial Plug&Socket

328

Accessories

334

Contents
Final Distribution
Miniature Circuit Breaker & Switch Disconnectors 002-029
HDB6

18mm Miniature Circuit Breaker

002

HDB6s

18mm Miniature Circuit Breaker

007

HDB9

18mm Miniature Circuit Breaker

011

HDB2

27mm Miniature Circuit Breaker

016

HDB6p

Phase-neutral Circuit Breaker

019

HDB3

Phase-neutral Circuit Breaker

021

HDB6IS

Switch Disconnector

023

HDB5

Switch Disconnector

025

HDG9

Switch Disconnector

027

Residual Current Devices

030-045

HDB6LE

Residual Current Operated Circuit Breaker

030

HDB6v

Residual Current Protection Module

033

HDB2LE

Residual Current Operated Circuit Breaker

036

HDB6pLE

Residual Current Operated Circuit Breaker

039

HDB3LE

Residual Current Operated Circuit Breaker

041

HDL6SP

Residual Current Operated Circuit Breaker

043

HDB6VR

Electromagnetic Type Residual Current Switch

044

Accessories for MCB&RCBO

046-050

SD,OF,MX+OF

046

Busbar

050

Control Devices

051-055

HDCH8P

Modular Contactor

051

HDRT8

Time Relay

054

Surge Protective Device

056-057

HDY1

056

Surge Protective Device

Distribution Box

058-062

HDPZ50 Series Consumer Box

058

HJXF

060

Metal Enclosure

Low-voltage Distribution
Molded Case Circuit Breaker

063-119

HDM6s

Molded Case Circuit Breaker

063

HDM6L

Earth-Leakage Circuit Breaker

086

HDM1

Molded Case Circuit Breaker

103

HDM1LE

Earth-Leakage Circuit Breaker

112

Air Circuit Breaker

120-193

HDW9

Air Circuit Breaker

120

HDW6

Air Circuit Breaker

169

Motor Control & Protection

Contactor&Thermal Overload Relay

194-245

HDC6

AC Contactor

194

HDR6

Thermal Overload Relay

210

HDC17-K

Mini AC Contactor

220

HDR17-18

Thermal Overload Relay

223

HJX2 AC

AC Contactor

227

HJRS1D

Thermal Overload Relay

233

HJRS2

Thermal Overload Relay

238

Definite Purpose Contactor


HDC9

Capacitor Switching Contactor

Relay

246-247

246

248-257

HDZ6

Contactor Relay

248

HDZ8P

Miniature Relay

251

HJSZ3

Electronic Time Relay

253

HXJ9

Phase Failure and Sequence Protection Relay

256

HDTL17

Impluse Relay

257

Motor Protector

258-264

HDP6

258

Motor Protector

Magnetic Starter

265-266

HDS2

265

Magnetic Starter

Power Energy Management


Current Transformer

267-270

HLMK Series

267

Current Transformer

Meter

271-283

HDDS607

Single-phase Electronic Watt-hour Meter

271

HDTS607

Three-phase Four-Wire Electronic Watt-hour Meter

273

HDSS607

Three-phase Three-Wire Electronic Watt-hour Meter

276

H72 Series

Panel Meter

279

H96 Series

Panel Meter

281

Digital Time Switch

284-287

HKG316T

Digital Time Switch

284

HKG316TD

Digital Time Switch

285

HKG816

Digital Time Switch

286

Voltage Stabilizer

288-294

HTND

Single-phase Full Automatic AC Voltage Stabilizer

288

HSJW

Three-phase Full Automatic AC Voltage Stabilizer

290

HSBW

Three-phase Compensation AC Voltage Stabilizer

292

Industrial Control Components


Control Signal

295-320

HLD11

Indicator Light

295

HLAY5

Pushbutton Switches

299

HLAY7

Pushbutton Switches

309

HLAY8

Pushbutton Switches

315

Fuse

321-327

HRT16

Fuse

321

HRT18

Fuse

324

Industrial Plug&Socket

328-333

HDPM

Moving Industrial Plugs

328

HDP

Fixed Industrial Plugs

329

HDSM

Moving Industrial Sockets

330

HDSF

Fixed Industrial Sockets

331

HDPS

Multi-function Plugs and Sockets

332

Accessories

334-339

HCCF

Cable Connector

334

HTB

Copper Terminal Blocks

335

HDIN

Din-rail

339

Miniature Circuit Breaker & Switch Disconnectors


Product Overview
18mm MCB

27mm MCB

Final Distribution

HDB6

S
HDB6s

002

In: 1-63A
Breaking Capacity: 3/4.5/6kA

007

In: 1-63A
Breaking Capacity: 4.5/6kA

019

In: 6-32A
Breaking Capacity: 4.5kA

Accessories

MX+OF

001

HDB2

011

In: 1-63A
Breaking Capacity: 6/10kA

016

In: 63-125A
Breaking Capacity: 10kA

Switch Disconnectors

18mm 1P+N MCB

HDB6p

HDB9

HDB3

021

In: 6-32A
Breaking Capacity: 3kA

HDB6IS
In: 20-125A

023

HDB5
In: 20-100A

025

HDG9
In: 32-125A

027

046

SD

OF

17

HDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A

Function

HDB6 miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Name

Breaking Capacity

Pole

Type

Rated current

HDB6

a: 3kA

1: 1P

B: B Curve

1: 1A

L: 4.5kA

2: 2P

C: C Curve

3: 3A

N: 6kA

3: 3P

D: D Curve

4: 4P
Type
1P

Rating
Width
(A)

1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63
1
3
6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

HDB6a1B1
HDB6a1B3
HDB6a1B6
HDB6a1B10
HDB6a1B16
HDB6a1B20
HDB6a1B25
HDB6a1B32
HDB6a1B40
HDB6a1B50
HDB6a1B63
HDB6L1B1
HDB6L1B3
HDB6L1B6
HDB6L1B10
HDB6L1B16
HDB6L1B20
HDB6L1B25
HDB6L1B32
HDB6L1B40
HDB6L1B50
HDB6L1B63
HDB6N1B1
HDB6N1B3
HDB6N1B6
HDB6N1B10
HDB6N1B16
HDB6N1B20
HDB6N1B25
HDB6N1B32
HDB6N1B40
-

C curve
HDB6a1C1
HDB6a1C3
HDB6a1C6
HDB6a1C10
HDB6a1C16
HDB6a1C20
HDB6a1C25
HDB6a1C32
HDB6a1C40
HDB6a1C50
HDB6a1C63
HDB6L1C1
HDB6L1C3
HDB6L1C6
HDB6L1C10
HDB6L1C16
HDB6L1C20
HDB6L1C25
HDB6L1C32
HDB6L1C40
HDB6L1C50
HDB6L1C63
HDB6N1C1
HDB6N1C3
HDB6N1C6
HDB6N1C10
HDB6N1C16
HDB6N1C20
HDB6N1C25
HDB6N1C32
HDB6N1C40
-

D curve
HDB6a1D1
HDB6a1D3
HDB6a1D6
HDB6a1D10
HDB6a1D16
HDB6a1D20
HDB6a1D25
HDB6a1D32
HDB6a1D40
HDB6a1D50
HDB6a1D63
HDB6L1D1
HDB6L1D3
HDB6L1D6
HDB6L1D10
HDB6L1D16
HDB6L1D20
HDB6L1D25
HDB6L1D32
HDB6L1D40
HDB6L1D50
HDB6L1D63
-

1
3
6
10
16
20
25
32
40
50
63

4
4
4
4
4
4
4
4
4
4
4

HDB6a2B1
HDB6a2B3
HDB6a2B6
HDB6a2B10
HDB6a2B16
HDB6a2B20
HDB6a2B25
HDB6a2B32
HDB6a2B40
HDB6a2B50
HDB6a2B63

HDB6a2C1
HDB6a2C3
HDB6a2C6
HDB6a2C10
HDB6a2C16
HDB6a2C20
HDB6a2C25
HDB6a2C32
HDB6a2C40
HDB6a2C50
HDB6a2C63

HDB6a2D1
HDB6a2D3
HDB6a2D6
HDB6a2D10
HDB6a2D16
HDB6a2D20
HDB6a2D25
HDB6a2D32
HDB6a2D40
HDB6a2D50
HDB6a2D63

2P

63: 63A

Breaking
Capacity
(kA)

4.5

Final Distribution

Order Information

Reference
B curve

Note: Width refers to multiple of 9 mm.


002

HDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A

Order Information
Type

Final Distribution

3P

Breaking
Capacity
(kA)

Rating
Width
(A)

Reference
B curve

C curve

D curve

4.5

1
3
6
10
16
20
25
32
40

HDB6L2B1
HDB6L2B3
HDB6L2B6
HDB6L2B10
HDB6L2B16
HDB6L2B20
HDB6L2B25
HDB6L2B32
HDB6L2B40

HDB6L2C1
HDB6L2C3
HDB6L2C6
HDB6L2C10
HDB6L2C16
HDB6L2C20
HDB6L2C25
HDB6L2C32
HDB6L2C40

HDB6L2D1
HDB6L2D3
HDB6L2D6
HDB6L2D10
HDB6L2D16
HDB6L2D20
HDB6L2D25
HDB6L2D32
HDB6L2D40

50
63

4
4
4
4
4
4
4
4
4
4
4

HDB6L2B50
HDB6L2B63

HDB6L2C50
HDB6L2C63

HDB6L2D50
HDB6L2D63

1
3
6
10
16
20
25
32
40
50
63

4
4
4
4
4
4
4
4
4
4
4

HDB6N2B1
HDB6N2B3
HDB6N2B6
HDB6N2B10
HDB6N2B16
HDB6N2B20
HDB6N2B25
HDB6N2B32
HDB6N2B40
-

HDB6N2C1
HDB6N2C3
HDB6N2C6
HDB6N2C10
HDB6N2C16
HDB6N2C20
HDB6N2C25
HDB6N2C32
HDB6N2C40
-

1
3
6
10
16
20
25
32
40
50
63

6
6
6
6
6
6
6
6
6
6
6

HDB6a3B1
HDB6a3B3
HDB6a3B6
HDB6a3B10
HDB6a3B16
HDB6a3B20
HDB6a3B25
HDB6a3B32
HDB6a3B40
HDB6a3B50
HDB6a3B63

HDB6a3C1
HDB6a3C3
HDB6a3C6
HDB6a3C10
HDB6a3C16
HDB6a3C20
HDB6a3C25
HDB6a3C32
HDB6a3C40
HDB6a3C50
HDB6a3C63

HDB6a3D1
HDB6a3D3
HDB6a3D6
HDB6a3D10
HDB6a3D16
HDB6a3D20
HDB6a3D25
HDB6a3D32
HDB6a3D40
HDB6a3D50
HDB6a3D63

4.5

1
3
6
10
16
20
25
32
40
50
63

6
6
6
6
6
6
6
6
6
6
6

HDB6L3B1
HDB6L3B3
HDB6L3B6
HDB6L3B10
HDB6L3B16
HDB6L3B20
HDB6L3B25
HDB6L3B32
HDB6L3B40
HDB6L3B50
HDB6L3B63

HDB6L3C1
HDB6L3C3
HDB6L3C6
HDB6L3C10
HDB6L3C16
HDB6L3C20
HDB6L3C25
HDB6L3C32
HDB6L3C40
HDB6L3C50
HDB6L3C63

HDB6L3D1
HDB6L3D3
HDB6L3D6
HDB6L3D10
HDB6L3D16
HDB6L3D20
HDB6L3D25
HDB6L3D32
HDB6L3D40
HDB6L3D50
HDB6L3D63

Note: Width refers to multiple of 9 mm.

003

HDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A

Order Information
Type

Rating
Width
(A)

Reference
B curve

C curve

1
3
6
10
16
20
25
32
40
50
63

6
6
6
6
6
6
6
6
6
6
6

HDB6N3B1
HDB6N3B3
HDB6N3B6
HDB6N3B10
HDB6N3B16
HDB6N3B20
HDB6N3B25
HDB6N3B32
HDB6N3B40
-

HDB6N3C1
HDB6N3C3
HDB6N3C6
HDB6N3C10
HDB6N3C16
HDB6N3C20
HDB6N3C25
HDB6N3C32
HDB6N3C40
-

1
3
6
10
16
20
25
32
40
50
63

8
8
8
8
8
8
8
8
8
8
8

HDB6a4B1
HDB6a4B3
HDB6a4B6
HDB6a4B10
HDB6a4B16
HDB6a4B20
HDB6a4B25
HDB6a4B32
HDB6a4B40
HDB6a4B50
HDB6a4B63

HDB6a4C1
HDB6a4C3
HDB6a4C6
HDB6a4C10
HDB6a4C16
HDB6a4C20
HDB6a4C25
HDB6a4C32
HDB6a4C40
HDB6a4C50
HDB6a4C63

HDB6a4D1
HDB6a4D3
HDB6a4D6
HDB6a4D10
HDB6a4D16
HDB6a4D20
HDB6a4D25
HDB6a4D32
HDB6a4D40
HDB6a4D50
HDB6a4D63

4.5

1
3
6
10
16
20
25
32
40
50
63

8
8
8
8
8
8
8
8
8
8
8

HDB6L4B1
HDB6L4B3
HDB6L4B6
HDB6L4B10
HDB6L4B16
HDB6L4B20
HDB6L4B25
HDB6L4B32
HDB6L4B40
HDB6L4B50
HDB6L4B63

HDB6L4C1
HDB6L4C3
HDB6L4C6
HDB6L4C10
HDB6L4C16
HDB6L4C20
HDB6L4C25
HDB6L4C32
HDB6L4C40
HDB6L4C50
HDB6L4C63

HDB6L4D1
HDB6L4D3
HDB6L4D6
HDB6L4D10
HDB6L4D16
HDB6L4D20
HDB6L4D25
HDB6L4D32
HDB6L4D40
HDB6L4D50
HDB6L4D63

1
3
6
10
16
20
25
32
40
50
63

8
8
8
8
8
8
8
8
8
8
8

HDB6N4B1
HDB6N4B3
HDB6N4B6
HDB6N4B10
HDB6N4B16
HDB6N4B20
HDB6N4B25
HDB6N4B32
HDB6N4B40
-

HDB6N4C1
HDB6N4C3
HDB6N4C6
HDB6N4C10
HDB6N4C16
HDB6N4C20
HDB6N4C25
HDB6N4C32
HDB6N4C40
-

D curve
-

Final Distribution

4P

Breaking
Capacity
(kA)

Note: Width refers to multiple of 9 mm.

004

HDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A

Technical Data
MCB

HDB6 18mm Circuit Breaker

Final Distribution

Standard
Certification
Poles
Rated Current In
Rated Voltage Ue
Insulation Voltage Ui
Electrical
Features

IEC60898-1
CB, CE, RoHS
1-4P
1,3,6,10,16,20,25,32,40,50,63 A
230/400V AC
500V

Breaking Capacity Icn


Rate
current(A)

Breaking
capacity lcn(kA)

Type

Poles

Voltage
(V)

1-63

B,C,D

1P
2P, 3P, 4P

230/400
400

1-63

4.5

B,C,D

1P
2P, 3P, 4P

1-40

B,C

1P
2P, 3P, 4P

230/400
400
230/400
400

50,63

4.5

B,C

1P
2P, 3P, 4P

230/400
400

Tripping Curve(see following tripping curve pictures)


B Curve:the magnetic release operates between 3 and 5 In
C Curve:the magnetic release operates between 5 and 10 In
D Curve:the magnetic release operates between 10 and 14 In

Mechanical
Features

Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature

Connection

Installation

Mounting
Accessories

005

4000 times
10000 times
2
treatment 2
-5C ~ +40C
Up to 25mm 2 cables

Rate
Current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

1-63

M5

2.5

4.5

35mm Din-rail
Contact Accessory
OF
Fault-indicating Accessories SD
Shunt -trip release
MX+OF

HDB6 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 3000/4500/6000A

Tripping Curve

HDB6 Miniature Circuit Breaker

Final Distribution

Overall Dimensions

Accessories

The Sketch Map of Installation with Breakers

SD

OF

HDB6

MX+OF

006

HDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A

Function

HDB6s miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Final Distribution

Order Information
Name

Breaking Capacity

Pole

Type

Rated current

HDB6s

L: 4.5kA

1: 1P

B: B Curve

1: 1A

N: 6kA

2: 2P

C: C Curve

2: 2A

3: 3P

D: D Curve

4: 4P
Type

Breaking
Capacity (kA)

Rating
(A)

Width

Reference
B curve

C curve

D curve

1P

4.5/6

1
2
3
4
5
6
8
10
13
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

HDB6sN1B1
HDB6sN1B2
HDB6sN1B3
HDB6sN1B4
HDB6sN1B5
HDB6sN1B6
HDB6sN1B8
HDB6sN1B10
HDB6sN1B13
HDB6sN1B16
HDB6sN1B20
HDB6sN1B25
HDB6sN1B32
HDB6sN1B40
HDB6sL1B50
HDB6sL1B63

HDB6sN1C1
HDB6sN1C2
HDB6sN1C3
HDB6sN1C4
HDB6sN1C5
HDB6sN1C6
HDB6sN1C8
HDB6sN1C10
HDB6sN1C13
HDB6sN1C16
HDB6sN1C20
HDB6sN1C25
HDB6sN1C32
HDB6sN1C40
HDB6sL1C50
HDB6sL1C63

HDB6sL1D1
HDB6sL1D2
HDB6sL1D3
HDB6sL1D4
HDB6sL1D5
HDB6sL1D6
HDB6sL1D8
HDB6sL1D10
HDB6sL1D13
HDB6sL1D16
HDB6sL1D20
HDB6sL1D25
HDB6sL1D32
HDB6sL1D40
HDB6sL1D50
HDB6sL1D63

2P

4.5/6

HDB6sN2B1

HDB6sN2C1

HDB6sL2D1

HDB6sN2B2

HDB6sN2C2

HDB6sL2D2

HDB6sN2B3

HDB6sN2C3

HDB6sL2D3

HDB6sN2B4

HDB6sN2C4

HDB6sL2D4

HDB6sN2B5

HDB6sN2C5

HDB6sL2D5

HDB6sN2B6

HDB6sN2C6

HDB6sL2D6

HDB6sN2B8

HDB6sN2C8

HDB6sL2D8

10

HDB6sN2B10

HDB6sN2C10

HDB6sL2D10

13

HDB6sN2B13

HDB6sN2C13

HDB6sL2D13

16

HDB6sN2B16

HDB6sN2C16

HDB6sL2D16

20

HDB6sN2B20

HDB6sN2C20

HDB6sL2D20

25

HDB6sN2B25

HDB6sN2C25

HDB6sL2D25

32

HDB6sN2B32

HDB6sN2C32

HDB6sL2D32

40

HDB6sN2B40

HDB6sN2C40

HDB6sL2D40

50

HDB6sL2B50

HDB6sL2C50

HDB6sL2D50

63

HDB6sL2B63

HDB6sL2C63

HDB6sL2D63

Note: Width refers to multiple of 9 mm.

007

63: 63A

HDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A

Order Information

Type

4P

Rating
(A)

Width

4.5/6

4.5/6

Reference
B curve

C curve

HDB6sN3B1

HDB6sN3C1

HDB6sL3D1

HDB6sN3B2

HDB6sN3C2

HDB6sL3D2

HDB6sN3B3

HDB6sN3C3

HDB6sL3D3

HDB6sN3B4

HDB6sN3C4

HDB6sL3D4

HDB6sN3B5

HDB6sN3C5

HDB6sL3D5

HDB6sN3B6

HDB6sN3C6

HDB6sL3D6

HDB6sN3B8

HDB6sN3C8

HDB6sL3D8

10

HDB6sN3B10 HDB6sN3C10 HDB6sL3D10

13

HDB6sN3B13 HDB6sN3C13 HDB6sL3D13

16

HDB6sN3B16 HDB6sN3C16 HDB6sL3D16

20

HDB6sN3B20 HDB6sN3C20 HDB6sL3D20

25

HDB6sN3B25 HDB6sN3C25 HDB6sL3D25

32

HDB6sN3B32 HDB6sN3C32 HDB6sL3D32

40

HDB6sN3B40 HDB6sN3C40 HDB6sL3D40

50

HDB6sL3B50 HDB6sL3C50 HDB6sL3D50

63

HDB6sL3B63 HDB6sL3C63 HDB6sL3D63

HDB6sN4B1

HDB6sN4C1

HDB6sL4D1

HDB6sN4B2

HDB6sN4C2

HDB6sL4D2

HDB6sN4B3

HDB6sN4C3

HDB6sL4D3

HDB6sN4B4

HDB6sN4C4

HDB6sL4D4

HDB6sN4B5

HDB6sN4C5

HDB6sL4D5

HDB6sN4B6

HDB6sN4C6

HDB6sL4D6

HDB6sN4B8

HDB6sN4C8

HDB6sL4D8

10

HDB6sN4B10 HDB6sN4C10 HDB6sL4D10

13

HDB6sN4B13 HDB6sN4C13 HDB6sL4D13

16

HDB6sN4B16 HDB6sN4C16 HDB6sL4D16

20

HDB6sN4B20 HDB6sN4C20 HDB6sL4D20

25

HDB6sN4B25 HDB6sN4C25 HDB6sL4D25

32

HDB6sN4B32 HDB6sN4C32 HDB6sL4D32

40

HDB6sN4B40 HDB6sN4C40 HDB6sL4D40

50

HDB6sL4B50 HDB6sL4C50 HDB6sL4D50

63

HDB6sL4B63 HDB6sL4C63 HDB6sL4D63

D curve

Note: Width refers to multiple of 9 mm.

008

Final Distribution

3P

Breaking
Capacity (kA)

HDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A

Technical Data
MCB

HDB6s 18mm Circuit Breaker

Final Distribution

Standard

IEC 60898-1

Certification

KEMA CB CE

Poles

1-4P

Rated Current In

1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V

Breaking Capacity Icn


Electrical
Features

Rate
current(A)

Breaking
capacity lcn(kA)

Type

Poles

1-40

B,C

1P
2P, 3P, 4P

230/400
400

50,63

4.5

B,C

1P
2P, 3P, 4P

230/400
400

1-63

4.5

1P
2P, 3P, 4P

230/400
400

Voltage
(V)

Tripping Curve ( see following tripping curve pictures)


B curve;the magnetic release operates between 3 and 5 In
C curve;the magnetic release operates between 5 and 10 In
D curve;the magnetic release operates between 10 and 14 In

Mechanical
Features

Electrical Durability

4000 times

Mechanical Durability

10000 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperture

-5C ~ +40C
Up to 25mm 2 cables

Connection

Installation

Rate
Current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

1-63

M5

2.5

4.5

35mm Din-rail

Mounting
Accessories

009

Contact Accessory

OF

Fault-indicating Accessory

SD

Shunt-trip Release

MX+OF

HDB6s 18mm Miniature Circuit Breaker


Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500/6000A

Tripping Curves

Final Distribution

Overall Dimensions
Unit: mm
4P
3P
2P
1P

88 max

: 67.210.43

Accessories

SD

OF

HDB6s

MX+OF

010

HDB9 18mm Miniature Circuit Breaker


Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A

Function

HDB9 miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Final Distribution

Order Information
Name

HDB9

Breaking
Capacity(kA)

Frame Size

N: 6kA

63:63AF

H: 10kA

Pole

Type

Rated current

1:1P

B:B Curve

1:1A

2:2P

C:C Curve

2:2A

3:3P

D:D Curve

4:4P

Breaking
Capacity(kA)

Type

1P

10

Rating(A)

Reference
B Curve

C Curve

D Curve
HDB9N631D1

HDB9N631B1

HDB9N631C1

HDB9N631B2

HDB9N631C2

HDB9N631D2

HDB9N631B4

HDB9N631C4

HDB9N631D4

HDB9N631B6

HDB9N631C6

HDB9N631D6

10

HDB9N631B10

HDB9N631C10

HDB9N631D10

16

HDB9N631B16

HDB9N631C16

HDB9N631D16

20

HDB9N631B20

HDB9N631C20

HDB9N631D20

25

HDB9N631B25

HDB9N631C25

HDB9N631D25

32

HDB9N631B32

HDB9N631C32

HDB9N631D32
HDB9N631D40

40

HDB9N631B40

HDB9N631C40

50

HDB9N631B50

HDB9N631C50

HDB9N631D50

63

HDB9N631B63

HDB9N631C63

HDB9N631D63

1
2
4
6
10
16
20
25
32
40
50
63

2
2
2
2
2
2
2
2
2
2
2
2

HDB9H631B1
HDB9H631B2
HDB9H631B4
HDB9H631B6
HDB9H631B10
HDB9H631B16
HDB9H631B20
HDB9H631B25
HDB9H631B32
HDB9H631B40
HDB9H631B50
HDB9H631B63

HDB9H631C1
HDB9H631C2
HDB9H631C4
HDB9H631C6
HDB9H631C10
HDB9H631C16
HDB9H631C20
HDB9H631C25
HDB9H631C32
HDB9H631C40
HDB9H631C50
HDB9H631C63

HDB9H631D1
HDB9H631D2
HDB9H631D4
HDB9H631D6
HDB9H631D10
HDB9H631D16
HDB9H631D20
HDB9H631D25
HDB9H631D32
HDB9H631D40
HDB9H631D50
HDB9H631D63

Note:Width refers to multiple of 9 mm.


B curve products need to customize

011

Width

63:63A

HDB9 18mm Miniature Circuit Breaker


Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A

Order Information
Type

10

3P

Rating(A)

Width

Reference
B Curve

C Curve

D Curve

HDB9N632B1

HDB9N632C1

HDB9N632D1

HDB9N632B2

HDB9N632C2

HDB9N632D2

HDB9N632B4

HDB9N632C4

HDB9N632D4

HDB9N632B6

HDB9N632C6

HDB9N632D6

10

HDB9N632B10

HDB9N632C10

HDB9N632D10

16

HDB9N632B16

HDB9N632C16

HDB9N632D16

20

HDB9N632B20

HDB9N632C20

HDB9N632D20

25

HDB9N632B25

HDB9N632C25

HDB9N632D25

32

HDB9N632B32

HDB9N632C32

HDB9N632D32

40

HDB9N632B40

HDB9N632C40

HDB9N632D40

50

HDB9N632B50

HDB9N632C50

HDB9N632D50

63

HDB9N632B63

HDB9N632C63

HDB9N632D63

HDB9H632B1

HDB9H632C1

HDB9H632D1

HDB9H632B2

HDB9H632C2

HDB9H632D2

HDB9H632B4

HDB9H632C4

HDB9H632D4

HDB9H632B6

HDB9H632C6

HDB9H632D6

10

HDB9H632B10

HDB9H632C10

HDB9H632D10

16

HDB9H632B16

HDB9H632C16

HDB9H632D16

20

HDB9H632B20

HDB9H632C20

HDB9H632D20

25

HDB9H632B25

HDB9H632C25

HDB9H632D25

32

HDB9H632B32

HDB9H632C32

HDB9H632D32

40

HDB9H632B40

HDB9H632C40

HDB9H632D40

50

HDB9H632B50

HDB9H632C50

HDB9H632D50

63

HDB9H632B63

HDB9H632C63

HDB9H632D63

HDB9N633B1

HDB9N633C1

HDB9N633D1

HDB9N633B2

HDB9N633C2

HDB9N633D2

HDB9N633B4

HDB9N633C4

HDB9N633D4

HDB9N633B6

HDB9N633C6

HDB9N633D6

10

HDB9N633B10

HDB9N633C10

HDB9N633D10

16

HDB9N633B16

HDB9N633C16

HDB9N633D16

20

HDB9N633B20

HDB9N633C20

HDB9N633D20

25

HDB9N633B25

HDB9N633C25

HDB9N633D25

32

HDB9N633B32

HDB9N633C32

HDB9N633D32

40

HDB9N633B40

HDB9N633C40

HDB9N633D40

50

HDB9N633B50

HDB9N633C50

HDB9N633D50

63

HDB9N633B63

HDB9N633C63

HDB9N633D63

Final Distribution

2P

Breaking
Capacity(kA)

Note:Width refers to multiple of 9 mm.


B curve products need to customize

012

HDB9 18mm Miniature Circuit Breaker


Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A

Order Information
Breaking
Capacity(kA)

Type

10
Final Distribution

4P

10

Rating(A)

Reference
B Curve

C Curve

D Curve

HDB9H633B1

HDB9H633C1

HDB9H633D1

HDB9H633B2

HDB9H633C2

HDB9H633D2

HDB9H633B4

HDB9H633C4

HDB9H633D4

HDB9H633B6

HDB9H633C6

HDB9H633D6

10

HDB9H633B10

HDB9H633C10

HDB9H633D10

16

HDB9H633B16

HDB9H633C16

HDB9H633D16

20

HDB9H633B20

HDB9H633C20

HDB9H633D20

25

HDB9H633B25

HDB9H633C25

HDB9H633D25

32

HDB9H633B32

HDB9H633C32

HDB9H633D32

40

HDB9H633B40

HDB9H633C40

HDB9H633D40

50

HDB9H633B50

HDB9H633C50

HDB9H633D50

63

HDB9H633B63

HDB9H633C63

HDB9H633D63

HDB9N634B1

HDB9N634C1

HDB9N634D1

HDB9N634B2

HDB9N634C2

HDB9N634D2

HDB9N634B4

HDB9N634C4

HDB9N634D4

HDB9N634B6

HDB9N634C6

HDB9N634D6

10

HDB9N634B10

HDB9N634C10

HDB9N634D10

16

HDB9N634B16

HDB9N634C16

HDB9N634D16

20

HDB9N634B20

HDB9N634C20

HDB9N634D20

25

HDB9N634B25

HDB9N634C25

HDB9N634D25

32

HDB9N634B32

HDB9N634C32

HDB9N634D32

40

HDB9N634B40

HDB9N634C40

HDB9N634D40

50

HDB9N634B50

HDB9N634C50

HDB9N634D50

63

HDB9N634B63

HDB9N634C63

HDB9N634D63

HDB9H634B1

HDB9H634C1

HDB9H634D1

HDB9H634B2

HDB9H634C2

HDB9H634D2

HDB9H634B4

HDB9H634C4

HDB9H634D4

HDB9H634B6

HDB9H634C6

HDB9H634D6

10

HDB9H634B10

HDB9H634C10

HDB9H634D10

16

HDB9H634B16

HDB9H634C16

HDB9H634D16

20

HDB9H634B20

HDB9H634C20

HDB9H634D20

25

HDB9H634B25

HDB9H634C25

HDB9H634D25

32

HDB9H634B32

HDB9H634C32

HDB9H634D32

40

HDB9H634B40

HDB9H634C40

HDB9H634D40

50

HDB9H634B50

HDB9H634C50

HDB9H634D50

63

HDB9H634B63

HDB9H634C63

HDB9H634D63

Note:Width refers to multiple of 9 mm.


B curve products need to customize

013

Width

HDB9 18mm Miniature Circuit Breaker


Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A

Technical Date
MCB

HDB9 18mm Circuit Breaker


IEC 60898-1

Certification

KEMA CB CE

Poles

l-4P
l,2,4,6,10,16,20,25,32,40,50,63A

Rated Current In

Electrical
Features

Final Distribution

Standard

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V
Breaking Capacity Icn

Rate
Current(A)

Breaking
Capacity Icn(kA)

Type

Poles

Voltage
(V)

1-63

B,C,D

1P

230/400

2P,3P,4P

400

1P

230/400

2P,3P,4P

400

1-63

10

B,C,D

Tripping Curve(see following tripping curve pictures)


B curve; the magnetic release operates between 3 and 5 In
C curve; the magnetic release operates between 5 and 10 In
D curve; the magnetic release operates between 10 and 14 In

Mechanical
Features

Connection

lnstallation

Electrical Durability

10000 times

Mechanical Durability

20000 times

Protection Degree

Ambient Temperture

-30 C~+70C

1-32A

Up to 25mm cables

40-63

Up to 35mm cables

Rate
Current(A)

Screw

Rated Torque(Nm)

Limiting Torque(Nm)

1-32

M5

2.0

2.5

40-63

M6.5

3.5

2.5

35mm Din-rail

Mounting
Contact Accessory
Accessories

OF

Fault-Indicating Accessory
Shunt-Trip Release

SD

MX+OF

014

HDB9 18mm Miniature Circuit Breaker


Standard:IEC 60898-1
Trip Curve:B,C and D curves
Breaking Capacity: 6000/10000A

Tripping Curve

Final Distribution

Overall Dimensions

Accessories

015

HDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A

Function

HDB2 miniature circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation
Final Distribution

Order Information
Type

Rating
(A)

Width
(in mod.of 9mm)

Reference
C curve

D curve

1P

63
80
100
125

3
3
3
3

HDB2H1C63
HDB2H1C80
HDB2H1C100
HDB2H1C125

HDB2H1D63
HDB2H1D80
HDB2H1D100
HDB2H1D125

2P

63
80
100
125

6
6
6
6

HDB2H2C63
HDB2H2C80
HDB2H2C100
HDB2H2C125

HDB2H2D63
HDB2H2D80
HDB2H2D100
HDB2H2D125

3P

63
80
100
125

9
9
9
9

HDB2H3C63
HDB2H3C80
HDB2H3C100
HDB2H3C125

HDB2H3D63
HDB2H3D80
HDB2H3D100
HDB2H3D125

4P

63
80
100
125

12
12
12
12

HDB2H4C63
HDB2H4C80
HDB2H4C100
HDB2H4C125

HDB2H4D63
HDB2H4D80
HDB2H4D100
HDB2H4D125

016

HDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A

Technical Data
MCB

Final Distribution

Electrical
Features

HDB2 27mm Circuit Breaker


Standard

IEC60947-2

Certification

CB, SEMKO, CE, RoHS

Poles

1-4P

Rated Current In

63,80,100,125A

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V

Breaking Capacity Icn


Rating
(A)

Poles

Voltage
(V)

Breaking capacity
(kA)

63~125

1P
2P,3P,4P

230
400

10
10

Tripping Curve (see following tripping curve pictures)


(C curve the magnetic release operates between 5 and 10 In)
(D curve the magnetic release operates between 10 and 14 In)
Electrical Durability
Mechanical
Features

Mechanical Durability
Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5C ~ +40C

Connection

Installation

Up to 50mm2 cables
Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

63-125

M7

5.5

Mounting
Accessories

017

35mm Din-rail
Contact Accessory:

OF

Shunt-trip Release:

MX+OF

HDB2 27mm Miniature Circuit Breaker


Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A

Tripping Curves

Final Distribution

Overall Dimensions

Accessories

MX+OF

OF

HDB2

018

HDB6p Phase-neutral Circuit Breaker


Standard: IEC 60898-1
Trip Curve: C curve
Breaking Capacity: 4500A

Function

Function

HDB6p phase-neutral circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control

Final Distribution

Order Information

6
10
16
20
25
32

1P+N

2
2
2
2
2
2

HDB6pC6
HDB6pC10
HDB6pC16
HDB6pC20
HDB6pC25
HDB6pC32

Technical Data
HDB6p Phase-neutral Circuit Breaker

MCB

Electrical
Features

Standard

IEC60898-1

Certification

CB

Poles

1P+N

Rated Current In

6,10,16,20,25,32A

Rated Voltage Ue

230V AC

Insulation Voltage Ui

500V

Breaking Capacity Icn

4.5KA

Tripping Curve (see following tripping curve pictures)


C curve:the magnetic release operates between 5 and 10In

Mechanical
Features

Electrical Durability

4000 times

Mechanical Durability

16000 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5~+40
Up to 10mm cables
2

Connection
Installation

Rate
current(A)
6-32

Mounting

019

Screw
M4

Rated Torque
(Nm)
2

35mm Din-rail

Limiting Torque
(Nm)
3

HDB6p Phase-neutral Circuit Breaker


Standard: IEC 60898-1
Trip Curve: C curve
Breaking Capacity: 4500A

Tripping Curve
HDB6p Phase-neutral Circuit Breaker

Final Distribution

Overall Dimensions

5.5

70max

45

35
78
88max

18

020

HDB3 Phase-neutral Circuit Breaker


Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A

Function

HDB3 phase-neutral circuit breakers combine the following functions:


Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Control
Isolation

Final Distribution

Order Information

1P+N

HDB3a5C6

10

HDB3a5C10

16

HDB3a5C16

20

HDB3a5C20

25

HDB3a5C25

32

HDB3a5C32

Technical Data
HDB3 Phase-neutral Circuit Breaker

MCB

Electrical
Features

Standard

IEC60898-1

Certification

CE

Poles

1P+N

Rated Current In

6,10,16,20,25,32A

Rated Voltage Ue

230V AC

Insulation Voltage Ui

500V

Breaking Capacity Icn

3kA

Tripping Curve (see following tripping curve pictures)


C curve:the magnetic release operates between 5 and 10In

Mechanical
Features

Electrical Durability

4000 times

Mechanical Durability

16000 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5C ~ +40C
Up to 10mm2 cables

Connection

Installation
Mounting

021

Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

6-32

M4

35mm Din-rail

HDB3 Phase-neutral Circuit Breaker


Standard: IEC 60898-1
Trip Curve: C curves
Breaking Capacity: 3000A

Tripping Curves

10000
5000
2000
1h

Final Distribution

1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.005
0.02
0.002
0.01
0.001
0.5

2 3 4 5 7 10

20 30 50 70 100 200

Overall Dimensions

022

HDB6IS Switch Disconnector


Standard: IEC 60947-3

Function

HDB6IS switch disconnectors combine the following functions:


Making and breaking normal load circuits
Isolation

Order Information
Final Distribution

Rating
(A)

Width
(in mod.of 9mm)

Reference

1P

20
32
63
100
125

2
2
2
2
2

HDB6IS120
HDB6IS132
HDB6IS163
HDB6IS1100
HDB6IS1125

2P

20
32
63
100
125

4
4
4
4
4

HDB6IS220
HDB6IS232
HDB6IS263
HDB6IS2100
HDB6IS2125

3P

20
32
63
100
125

6
6
6
6
6

HDB6IS320
HDB6IS332
HDB6IS363
HDB6IS3100
HDB6IS3125

4P

20
32
63
100
125

8
8
8
8
8

HDB6IS420
HDB6IS432
HDB6IS463
HDB6IS4100
HDB6IS4125

Type

023

HDB6IS Switch Disconnector


Standard: IEC 60947-3

Technical Data
HDB6IS Switch Disconnector
r

Switch Disconnector

Features

IEC60947-3

Certification

CB,CE,SEMKO

Poles

1-4P

Rated Current In

203263100,125A

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V

Final Distribution

Electrical

Standard

Short-time Withstand

Mechanical
Features

Capacity for 1s

12le

Electrical Durability

1500 times

Mechanical Durability

8500 times

Protection Degree

Ambient Temperature

5 C ~ +40 C

Tropicalization

treatment 2

Up to 50mm2 cables

Connection

Installation

Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

20-125

M7

5.5

Mounting

35mm Din-rail

Overall Dimensions

024

HDB5 Switch Disconnector


Standard: IEC 60947-3

Function

HDB5 switch disconnectors combine the following functions:


Making and breaking normal load circuits
Isolation

Order Information
Final Distribution

025

Type

Voltage
(V)

Rating
(A)

Width
(in mod.of 9mm)

Reference

1P

230/400

20
32
63
100

2
2
2
2

HDB5120
HDB5132
HDB5163
HDB51100

2P

400

20
32
63
100

4
4
4
4

HDB5220
HDB5232
HDB5263
HDB52100

3P

400

20
32
63
100

6
6
6
6

HDB5320
HDB5332
HDB5363
HDB53100

4P

400

20
32
63
100

8
8
8
8

HDB5420
HDB5432
HDB5463
HDB54100

HDB5 Switch Disconnector


Standard: IEC 60947-3

Technical Data
HDB5 Switch Disconnector

Switch Disconnector

IEC60947-3

Poles

1-4P

Rated Current In

20, 32, 63, 100A

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V

Rated Short-circuit

1066A(Ie:20~63A)

Making Capacity

1692A(Ie:100A), Peak current

Short-time Withstand

756A(Ie:20~63A)

Capacity for 1s

1200A(Ie:100A)

Electrical Durability

1500 times

Mechanical Durability

8500 times
2
-5C ~ +40C

Protection Degree
Mechanical
Features

Ambient Temperature
Tropicalization

treatment 2
-25C ~+55C

Storage Temperature

Up to 50mm2 cables

Connection

Installation

Final Distribution

Electrical
Features

Standard

Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

20-100

M7

5.5

Mounting

35mm Din-rail

Overall Dimensions

026

HDG9 Switch Disconnector


Standard:IEC 60947-3

Function

HDG9 switch disconnectors combine the folIowing functions:


Making and breaking normal load circuits
Isolation

Final Distribution

Order Information
Type

Rating(A)

Width
(in mod.of 9mm)

32

HDG9125132

63

HDG9125163

100

HDG91251100

125

HDG91251125

32

HDG9125232

63

HDG9125263

100

HDG91252100

125

HDG91252125

32

HDG9125332

63

HDG9125363

100

HDG91253100

125

HDG91253125

32

HDG9125432

63

HDG9125463

100

HDG91254100

125

HDG91254125

Reference

1P

2P

3P

4P

027

HDG9 Switch Disconnector


Standard:IEC 60947-3

Technical Date
Switch
Disconnector
Standard

IEC 60947-3

Certification

CB,CE,TUV

Poles

1-4P

Rated Current In

32,63,100,125A

Rated Voltage Ue

230/400VAC

Insulation Voltage Ui

500V

Final Distribution

Electrical
Features

HDG9 Switch Disconnector

Short-time Withstand
Current for 1s

Mechanical
Features

12le

Electrical Durability

10000 times

Mechanical Durability

20000 times

Protection Degree

Ambient Temperture

-30 C~+70C

Tropicalization

treatment 2
Up to 50mm cables

Connection

lnstallation

Rate
current(A)

Screw

Rated Torque(Nm)

Limiting Torque(Nm)

32-125

M6.5

3.5

3.5

Mounting

35mm Din-rail

Overall Dimensions

028

Residual Current Devices Overview

18mm RCBO

Add-on RCD

Final Distribution

HDB6LE

030

Sensitivity: 30,50,100,200,300mA
In: 6-60A
Breaking Capacity: 3kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P

27mm RCBO

HDB2LE

HDB6v

033

Sensitivity: 30,100,300mA
In: V32A, V63A
Poles: 1P+N, 2P, 3P, 3P+N, 4P

Phase-neutral RCBO

036

Sensitivity: 30,100,300mA
In: 63-100A
Breaking Capacity: 10kA
Poles: 1P+N, 2P, 3P, 3P+N, 4P

HDB6pLE

039

Sensitivity: 30mA
In: 6-40A
Breaking Capacity: 4.5kA
Poles: 1P+N

Sensitivity: 30mA
In: 6-40A
Breaking Capacity: 4.5kA
Poles: 1P+N

RCCB

HDL6SP
Sensitivity:30mA
Breaking Capacity:6000A
Poles: 1P+N

029

043

HDB6VR
Sensitivity:30,100,300mA
In: 10-100A
Poles: 2P,4P

HDB3LE

044

041

HDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA

Function

Order Information
Type

Voltage
(V)

Sensitivity
(mA)

Rating
(A)

Width

Reference
C curve

D curve

1P+N

230

30

6
10
16
20
25
32
40
50
60

5
5
5
5
5
5
6
6
6

HDB6LEa1C6S
HDB6LEa1C10S
HDB6LEa1C16S
HDB6LEa1C20S
HDB6LEa1C25S
HDB6LEa1C32S
HDB6LEa1C40S
HDB6LEa1C50S
HDB6LEa1C60S

HDB6LEa1D6S
HDB6LEa1D10S
HDB6LEa1D16S
HDB6LEa1D20S
HDB6LEa1D25S
HDB6LEa1D32S
HDB6LEa1D40S
HDB6LEa1D50S
HDB6LEa1D60S

2P

230

30

6
10
16
20
25
32
40
50
60

7
7
7
7
7
7
8
8
8

HDB6LEa2C6S
HDB6LEa2C10S
HDB6LEa2C16S
HDB6LEa2C20S
HDB6LEa2C25S
HDB6LEa2C32S
HDB6LEa2C40S
HDB6LEa2C50S
HDB6LEa2C60S

HDB6LEa2D6S
HDB6LEa2D10S
HDB6LEa2D16S
HDB6LEa2D20S
HDB6LEa2D25S
HDB6LEa2D32S
HDB6LEa2D40S
HDB6LEa2D50S
HDB6LEa2D60S

3P

400

30

6
10
16
20
25
32
40
50
60

10
10
10
10
10
10
12
12
12

HDB6LEa3C6S
HDB6LEa3C10S
HDB6LEa3C16S
HDB6LEa3C20S
HDB6LEa3C25S
HDB6LEa3C32S
HDB6LEa3C40S
HDB6LEa3C50S
HDB6LEa3C60S

HDB6LEa3D6S
HDB6LEa3D10S
HDB6LEa3D16S
HDB6LEa3D20S
HDB6LEa3D25S
HDB6LEa3D32S
HDB6LEa3D40S
HDB6LEa3D50S
HDB6LEa3D60S

3P+N

400

30

6
10
16
20
25
32
40
50
60

11
11
11
11
11
11
14
14
14

HDB6LEa6C6S
HDB6LEa6C10S
HDB6LEa6C16S
HDB6LEa6C20S
HDB6LEa6C25S
HDB6LEa6C32S
HDB6LEa6C40S
HDB6LEa6C50S
HDB6LEa6C60S

HDB6LEa6D6S
HDB6LEa6D10S
HDB6LEa6D16S
HDB6LEa6D20S
HDB6LEa6D25S
HDB6LEa6D32S
HDB6LEa6D40S
HDB6LEa6D50S
HDB6LEa6D60S

Note: 1. Width refers to multiple of 9 mm.


2. If the sensivitivity is 30mA,it's marked with "S" in the reference number.Aslo, 50mA is marked with
"W"; 100mA is marked with "Y"; 200mA is marked with "R"; 300mA is marked with "T".

030

Final Distribution

HDB6LE electronic type residual current operated circuit breakers combine the following functions:
Overload protection
Protection against short-circuit currents
Protection for users against indirect currents
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation

HDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA

Order Information
Voltage
(V)

Sensitivity
(mA)

Rating
(A)

Width

Reference
C curve

D curve

4P

400

30

6
10
16
20
25
32
40
50
60

13
13
13
13
13
13
16
16
16

HDB6LEa4C6S
HDB6LEa4C10S
HDB6LEa4C16S
HDB6LEa4C20S
HDB6LEa4C25S
HDB6LEa4C32S
HDB6LEa4C40S
HDB6LEa4C50S
HDB6LEa4C60S

HDB6LEa4D6S
HDB6LEa4D10S
HDB6LEa4D16S
HDB6LEa4D20S
HDB6LEa4D25S
HDB6LEa4D32S
HDB6LEa4D40S
HDB6LEa4D50S
HDB6LEa4D60S

Final Distribution

Type

Note: 1. Width sensitivity refers to multiple of 9 mm.


2. If the sensitivity is 30mA,it's marked with "S" in the reference number.Also, 50mA is marked with
"W"; 100mA is marked with "Y"; 200mA is marked with "R"; 300mA is marked with "T".

Technical Data
HDB6LE Residual Current Operated Circuit Breaker

RCBO

Electrical
Features

Standard

IEC 61009-1

Electronic Type

AC

Poles

1P+N,2P,3P,3P+N,4P

Rated Current In

6,10,16,20,25,32,40,50,60A

Rated Voltage Ue

230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P

Insulation Voltage Ui

500V

Breaking Capacity

3KA

Sensitivity

30,50,100,200,300mA

Tripping Curve(see following tripping curve pictures)


C curve:the magnetic release operates between 5 and 10
D curve:the magnetic release operates between 10 and 14

Mechanical
Features

6-32A,Up to 16mm2 cables, 40-60A,Up to 25mm2 cables

Connection

Rate
current(A)
Installation

Mounting
Accessories

031

2000 times
2000 times
2
treatment 2
-5C ~ +40C

Electrical Durability
Mechanical Durability
Protection Degree
Tropicalization
Ambient Temperature

6-32
40-60

Screw
M4
M5

Rated Torque
(Nm)

Limiting Torque
(Nm)

2.0
2.5

3.0
4.5

35mm Din-rail
Contact Accessory:
OF
Fault-indicating Accessory: SD

HDB6LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 3000A
Sensitivity: 30,50,100,200,300mA

Tripping Curves

Final Distribution

Overall Dimensions
HDB6LE-32

HDB6LE-60

Accessories

SD

OF

HDB6LE

032

HDB6v Residual Current Protection Module


Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA

Function

HDB6v can be assembled with HDB6s to be residual current breaker overcurrent


Protection of persons against indirect contacting
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products marked "G"

Final Distribution

Order Information
Frame

Type

Voltage
(V)

Sensitivity
(mA)

Width

Reference

V32

1P+N

230

30

HDB6v321N

100

HDB6v321NR100

300

HDB6v321NR300

30

HDB6v322P

100

HDB6v322PR100

300

HDB6v322PR300

30

10

HDB6v323P

100

10

HDB6v323PR100

300

10

HDB6v323PR300

30

11

HDB6v323N

100

11

HDB6v323NR100

300

11

HDB6v323NR300

30

13

HDB6v324P

100

13

HDB6v324PR100

300

13

HDB6v324PR300

30

HDB6v631N

100

HDB6v631NR100

300

HDB6v631NR300

30

HDB6v632P

100

HDB6v632PR100

300

HDB6v632PR300

30

12

HDB6v633P

100

12

HDB6v633PR100

300

12

HDB6v633PR300

30

14

HDB6v633N

100

14

HDB6v633NR100

300

14

HDB6v633NR300

30

16

HDB6v634P

100

16

HDB6v634PR100

300

16

HDB6v634PR300

2P

3P

230

400

3P+N

4P

V63

1P+N

2P

3P

230

230

400

3P+N

4P

Note: Width refers to mutultiple of 9mm.

033

HDB6v Residual Current Protection Module


Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA

Technical Data
HDB6v Residual Current Protection Module

RCBO

Mechanical
Features

IEC61009-1

Electronic Type

AC

Poles

1P+N, 2P, 3P, 3P+N, 4P

Rated Current In

V32 In32A V63 In63A

Rated Voltage Ue

230/400V AC

Rated Insulation Voltage

500V

Breaking Capacity

after HDB6s assembled with


reference to HDB6s parameters

Sensitivity

30,100,300mA

Tripping Indication

On HDB6v is a residual opening


current indication, which distinguish
residual current from other faults

Manual Control

Manual control:allows for two kinds of reset


HDB6v resets at the same time with breaker
HDB6v resets before breaker

G products offer
overvoltage protection

280V5% AC,applicable to
products with 1P+N and 2P

Electrical Durability

2000 times(In25A) 1000times(In>25A)

Mechanical Durability

2000 times

Protection Degree

IP20

Tropicaliation

treatrment 2

Ambient Temperature

-5C ~ +40C

-Up to 16mm2 cables(V32)


-Up to 25mm2 cables(V63)

Connection

Installation

Final Distribution

Electrical
Features

Standard

Rate
current(A)
V32
V63

Screw
M4
M5

Rated Torque
(Nm)
2.2
2.5

Limiting Torque
(Nm)
3.0
4.5

034

HDB6v Residual Current Protection Module


Standard: IEC 61009-1
Electronic type: AC
Sensitivity: 30,100,300mA

Overall Dimensions

Final Distribution

Pole

V32

V63

1P+N

450.32

540.37

2P

630.37

720.43

3P

900.5

1080.57

3P+N

990.5

1260.64

4P

1170.57

1440.72

Assembly

HDB6v can be assembled with HDB6s to be residual current breaker overcurrent


Protection of persons against indirect contacts
Supplementary protection of persons against direct contacting
Prevention of electric-caused fire
Overvoltage protection by products markedG

035

HDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA

Function

HDB2LE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
Final Distribution

Order Information
Type

Width

Sensitivity
(mA)

Rating
(A)

Reference
C curve

D curve

1P+N

30
30
30
100
100
100
300
300
300

63
80
100
63
80
100
63
80
100

HDB2LEH1C63S
HDB2LEH1C80S
HDB2LEH1C100S
HDB2LEH1C63Y
HDB2LEH1C80Y
HDB2LEH1C100Y
HDB2LEH1C63T
HDB2LEH1C80T
HDB2LEH1C100T

HDB2LEH1D63S
HDB2LEH1D80S
HDB2LEH1D100S
HDB2LEH1D63Y
HDB2LEH1D80Y
HDB2LEH1D100Y
HDB2LEH1D63T
HDB2LEH1D80T
HDB2LEH1D100T

2P

30
30
30
100
100
100
300
300
300

63
80
100
63
80
100
63
80
100

HDB2LEH2C63S
HDB2LEH2C80S
HDB2LEH2C100S
HDB2LEH2C63Y
HDB2LEH2C80Y
HDB2LEH2C100Y
HDB2LEH2C63T
HDB2LEH2C80T
HDB2LEH2C100T

HDB2LEH2D63S
HDB2LEH2D80S
HDB2LEH2D100S
HDB2LEH2D63Y
HDB2LEH2D80Y
HDB2LEH2D100Y
HDB2LEH2D63T
HDB2LEH2D80T
HDB2LEH2D100T

3P

12

30
30
30
100
100
100
300
300
300

63
80
100
63
80
100
63
80
100

HDB2LEH3C63S
HDB2LEH3C80S
HDB2LEH3C100S
HDB2LEH3C63Y
HDB2LEH3C80Y
HDB2LEH3C100Y
HDB2LEH3C63T
HDB2LEH3C80T
HDB2LEH3C100T

HDB2LEH3D63S
HDB2LEH3D80S
HDB2LEH3D100S
HDB2LEH3D63Y
HDB2LEH3D80Y
HDB2LEH3D100Y
HDB2LEH3D63T
HDB2LEH3D80T
HDB2LEH3D100T

3P+N

12

30
30
30
100
100
100
300
300
300

63
80
100
63
80
100
63
80
100

HDB2LEH6C63S
HDB2LEH6C80S
HDB2LEH6C100S
HDB2LEH6C63Y
HDB2LEH6C80Y
HDB2LEH6C100Y
HDB2LEH6C63T
HDB2LEH6C80T
HDB2LEH6C100T

HDB2LEH6D63S
HDB2LEH6D80S
HDB2LEH6D100S
HDB2LEH6D63Y
HDB2LEH6D80Y
HDB2LEH6D100Y
HDB2LEH6D63T
HDB2LEH6D80T
HDB2LEH6D100T

Note: Width refers to multiple of 9mm .

036

HDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA

Order Information
Type
4P

Width
15

Sensitivity Rating
(A)
(mA)

Final Distribution

30
30
30
100
100
100
300
300
300

63
80
100
63
80
100
63
80
100

Reference
C curve
HDB2LEH4C63S
HDB2LEH4C80S
HDB2LEH4C100S
HDB2LEH4C63Y
HDB2LEH4C80Y
HDB2LEH4C100Y
HDB2LEH4C63T
HDB2LEH4C80T
HDB2LEH4C100T

D curve
HDB2LEH4D63S
HDB2LEH4D80S
HDB2LEH4D100S
HDB2LEH4D63Y
HDB2LEH4D80Y
HDB2LEH4D100Y
HDB2LEH4D63T
HDB2LEH4D80T
HDB2LEH4D100T

Note: Width refers to multiple of 9mm .

Technical Data
RCBO

Electrical
Features

HDB2LE Residual Current Operated Circuit Breaker


Standard

IEC60947-2

Electronic Type

AC

Poles

1P+N,2P,3P,3P+N,4P

Rated Current In

63,80,100A

Rated Voltage Ue

230V for 1P+N; 400V for 2P/3P/3P+N/4P

Insulation Voltage

500V

Breaking Capacity Ui

10KA

Sensitivity

30,100,300mA

Tripping Curve ( see following tripping curve pictures)


C curve:the magnetic release operated between 5 and 10 In
D curve:the magnetic release operated between 10 and 14 In

Mechanical
Features

Electrical Durability

1500 times

Mechanical Durability

8500 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5C ~ +40C

Up to 50mm2 cables

Connection

Installation

Rate
current(A)

Screw

63-100

Accessories

037

M7

Rated Torque
(Nm)

Limiting Torque
(Nm)

5.5

Contact Accessory:

OF

Shunt -trip Release:

MX+OF

HDB2LE Residual Current Operated Circuit Breaker


Standard: IEC 60947-2
Electronic type: AC
Breaking Capacity: 10000A
Sensitivity: 30, 100, 300mA

Tripping Curve

Final Distribution

Overall Dimensions

Accessories

MX+OF

OF

HDB2LE

038

HDB6pLE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA

Function

HDB6pLE electronic type residual current operated circuit breakers combine the following functions:
Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contacts
Additional protection for users against direct contacts (30mA)

Final Distribution

Protection of electrical installations against insulation faults (re hazard, etc)


Isolation

Order Information
Type

Width
(mm)

Rating(A)

1P+N

36

6
10
16
20
25
32
40

Reference
C curve
HDB6pLEC6
HDB6pLEC10
HDB6pLEC16
HDB6pLEC20
HDB6pLEC25
HDB6pLEC32
HDB6pLEC40

Technical Data
HDB6pLE Residual Current Operated Circuit Breaker

RCBO

Electrical
Features

Standard

IEC61009-1

Certification
Electronic Type

CB
AC

Poles

1P+N

Rated Current In

6,10,16,20,25,32,40A

Rated Voltage Ue

230V AC

Insulation Voltage Ui

500V

Breaking Capacity

4.5KA

Sensitivity

30mA

Tripping Curve (see following tripping curve pictures)


C curve:the magnetic release operates between 5 and 10 In

Mechanical
Features

Electrical Durability

2000 times

Mechanical Durability

4000 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5~+40
2

Up to 25mm cables

Connection
Installation

Mounting

039

Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

6-40

M5

2.5

4.5

35mm Din-rail

HDB6pLE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA

Tripping Curve

HDB6pLE Residual Current Operated Circuit Breaker


Final Distribution

Overall Dimensions

040

HDB3LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA

Function

HDB3LE electronic type residual current operated circuit breakers combine the following functions:

Final Distribution

Protection of circuits against overload currents


Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation

Order Information
Type

Width
(mm)

Rating(A)

1P+N

36

6
10
16
20
25
32
40

Reference
C curve
HDB3LEL5C6S
HDB3LEL5C10S
HDB3LEL5C16S
HDB3LEL5C20S
HDB3LEL5C25S
HDB3LEL5C32S
HDB3LEL5C40S

Technical Data
RCBO

Electrical
Features

HDB3LE Residual Current Operated Circuit Breaker


Standard

IEC61009-1

Electronic Type

AC

Poles

1P+N

Rated Current In

6,10,16,20,25,32,40A

Rated Voltage Ue

230V AC

Insulation Voltage Ui

500V

Breaking Capacity

4.5KA

Sensitivity

30mA

Tripping Curve (see following tripping curve pictures)


C curve:the magnetic release operates between 5 and 10 In

Mechanical
Features

Electrical Durability

2000 times

Mechanical Durability

2000 times

Protection Degree

Tropicalization

treatment 2

Ambient Temperature

-5C ~ +40C
Up to 16mm2 cables

Connection
Installation

Mounting

041

Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

6-40

M5

2.5

4.5

35mm Din-rail

HDB3LE Residual Current Operated Circuit Breaker


Standard: IEC 61009-1
Electronic type: AC
Breaking Capacity: 4500A
Sensitivity: 30mA

Tripping Curve
HDB3LE Residual Current Operated Circuit Breaker

Final Distribution

Overall Dimensions

042

HDL6SP Residual Current Operated Circuit Breaker


Standard:IEC61009-1
Breaking Capacity:6000A
Sensitivity:30mA

Function

HDL6SP Single phase residual current operated circuit breaker can offer earth leakage
protection. Usually it can be used with HDB6S.

Order Information
Final Distribution

Poles

Rating (A)

Sensitivity

Reference
B Curve

C Curve

1P+N

30mA

HDL6SPN5B6S

HDL6SPN5C6S

10

30mA

HDL6SPN5B10S HDL6SPN5C10S

16

30mA

HDL6SPN5B16S HDL6SPN5C16S

20

30mA

HDL6SPN5B20S HDL6SPN5C20S

25

30mA

HDL6SPN5B25S HDL6SPN5C25S

32

30mA

HDL6SPN5B32S HDL6SPN5C32S

40

30mA

HDL6SPN5B40S HDL6SPN5C40S

Technical information
Standard
Breaking Capacity
Poles
Rated Current
Rated Voltage
Rated Tripping Current
Residual Current off time
Characteristic
Electrical endurance
Mechanical endurance
Protection degree
Connection terminal
Type of terminal

Overall Dimensions

043

IEC61009
6KA
1P+N
6,10,16,20,25,32,40A
230VAC
10mA
0.1s
B.C
10000
20000
2540
Flexible conductor 16mm
2
Rigid conductor 25mm
Lug type and Pin type

HDB6VR
Residual Current Operated Circuit Breaker

Standard:IEC 61008-1
RCCB Type: A C , A
Sensitivity: 30, 100, 300mA

Function

HDB6VR Residual current operated circuit breakers combine the following functions:

Protection for electrical installations against insulation faults (re hazard, etc)

Order Information

63AF

10

16

25

40

63

80

100AF

100

4P

63AF

10

16

25

40

63

100AF

80

100

30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300

HDB6VR210SC
HDB6VR210YC
HDB6VR210TC
HDB6VR216SC
HDB6VR216YC
HDB6VR216TC
HDB6VR225SC
HDB6VR225YC
HDB6VR225TC
HDB6VR240SC
HDB6VR240YC
HDB6VR240TC
HDB6VR263SC
HDB6VR263YC
HDB6VR263TC
HDB6VR280SC
HDB6VR280YC
HDB6VR280TC
HDB6VR2100SC
HDB6VR2100YC
HDB6VR2100TC

HDB6VR210SA
HDB6VR210YA
HDB6VR210TA
HDB6VR216SA
HDB6VR216YA
HDB6VR216TA
HDB6VR225SA
HDB6VR225YA
HDB6VR225TA
HDB6VR240SA
HDB6VR240YA
HDB6VR240TA
HDB6VR263SA
HDB6VR263YA
HDB6VR263TA
HDB6VR280SA
HDB6VR280YA
HDB6VR280TA
HDB6VR2100SA
HDB6VR2100YA
HDB6VR2100TA

30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300
30
100
300

HDB6VR410SC
HDB6VR410YC
H DB6VR410TC
HDB6VR416SC
HDB6VR416YC
HDB6VR416TC
HDB6VR425SC
HDB6VR425YC
HDB6VR425TC
HDB6VR440SC
HDB6VR440YC
HDB6VR440 TC
HDB6VR463 SC
HDB6VR463 YC
HDB6VR463 TC
HDB6VR480 SC
HDB6VR480 YC
HDB6VR480 TC
HDB6VR4100SC
HDB6VR4100YC
HDB6VR4100TC

HDB6VR410SA
HDB6VR410YA
HDB6VR410TA
HDB6VR416SA
HDB6VR416YA
HDB6VR416TA
HDB6VR425SA
HDB6VR425YA
HDB6VR425TA
HDB6VR440SA
HDB6VR440YA
HDB6VR440TA
HDB6VR463S A
HDB6VR463Y A
HDB6VR463TA
HDB6VR480S A
HDB6VR480Y A
HDB6VR480TA
HDB6VR4100SA
HDB6VR4100YA
HDB6VR4100TA

044

Final Distribution

2P

Final Distribution
Final Distribution

Protection for users against indirect contacts


Additional protection for users against direct contacts (30mA)

HDB6VR
Residual Current Operated Circuit Breaker
Standard: IEC 61008-1
RCCB Type: AC,A
Sensitivity: 30, 100, 300mA

RCCB

HDB6VR Residual Current Operated Circuit Breaker

Final Distribution

Standard

IEC 61008-1

Certification

TUV,CE, CB

Type

AC,A

Electrical

Poles

2P4P
,

Features

Rated Current In

10,16,25,32,40,63,80,100 A

Rated Voltage Ue

230/400V AC

Insulation Voltage Ui

500V

Sensitivity

Mechanical
Features

Connection

Installation

30,100,300mA

Electrical Durability

1000 times

Mechanical Durability

2000 times

Overload or Short
Circuit Protection

no

Tripping Indication

Instantaneous, rated residual


operated current, unadjustable

Fault Curren Indicator

Mechanical indication in the front

Protection Degree

Tropicalization

Treatment 2

Ambient Temperature

-25

~+40
2

Up to 35mm cables(In63A

Up to 25mm
Rate
current(A)

Screw

Rated Torque
(Nm)

Limiting Torque
(Nm)

25-100

M5

2.0

4.5

35mm Din-rail

Mounting
Power source
Auxilary

No need

Overall Dimensions

36
72

61.7

45

35.4

78.5

5.5

2P
4P

43.50.6
700.6

HDB6VR-63

045

HDB6VR-100

Accessories

HDB6,HDB6LE

The sketch map of installation with breaker

Final Distribution

SD

OF

Breaker

MX+OF

Remote Control Auxiliaries


SD fault-indicating switch

OF contact auxiliary
Indicate ON or OFF state of the breaker

Sent out fault signal on the front when breaking down

Basic type of auxiliary contact:1NO+1NC

Indicator on the front to show fault trip

Connection: 1-4mm2 cables

Basic type of auxiliary contact:1NO+1NC


Connection: 1-4mm2 cables

Tripping Device

Introductions

MX+OF shunt trip release

OF, SD must be assembled on the left ,one auxiliary only

Indicate ON or OFF state of the breaker

must
be assembled
the left
right,
Each timeMX+OF
only one
auxiliary
accepted on
in the
of one
MCBMX+OF only

Make the assembled breaker trip once got signal

MX+OF must be assembled on the right, one MX+OF only

Basic type of auxiliary contact:1NO+1NC

CDB6LE can't assemble MX+OF

Connection: 1-4mm2 cables

Order Information
Type

Width(mm) Voltage(V)

Reference

OF

HDB6OF

SD

HDB6SD

MX+OF

18

AC/DC 12V

HDB6MX12

18

AC/DC 24V

HDB6MX24

18

AC/DC 48V

HDB6MX48

18

AC 110V

HDB6MX110

18

AC 130V

HDB6MX130

18

AC 230V

HDB6MX230

18

AC 400V

HDB6MX400

046

Accessories
HDB9,HDB9LE

Accessory
The sketch map of installation with breakers

Final Distribution

Remote Control Auxiliaries


OF contact auxiliary

SD fault-indicating switch

Indicate ON or OFF state of the breaker

Sent out fault signal on the font when breaking down

Basic type of auxiliary contact: 1NO+INC

Indicator on the front to show fault trip


Basic type of auxiliary contact:1NO+1NC

Tripping Device

Introductions

MX+OF shunt trip release


Indicate ON or OFF state of the breaker
Without tools ,directly installed on the left of MCB

Without tools ,direct installed on the left of MCB


Each MCB maximum assembles 3 control auxiliaries(OF or SD)

Order Information
Type

047

Width(mm)

Voltage(V)

Reference

HDB963OF

HDB963SD

18

AC/DC 12/24V

HDB963MX24

18

AC/DC 48V

HDB963MX48

18

AC 100-415V
DC 110-130V

HDB963MX415

Accessories

HDB6s

The sketch map of installation with breakers

Final Distribution

SD

OF

HDB6s

MX+OF

Remote Control Auxiliaries


OF contact auxiliary

SD fault-indicating switch

Indicate ON or OFF state of the breaker

Sent out fault signal when breaking down

Basic type of auxiliary contact:1NO+1N C

Indicator on the front to show fault trip

Connectio n:1-4mm cables

Basic type of auxiliary contact:1NO+1NC


Connection:1-4mm2 cables

Tripping Device

Introductions

MX+OF shunt trip release

OF,SD must be assembled on the left ,one auxiliary only

Indicate ON or OFF state of the breaker

must
be assembled
the left
left of
,one
auxiliary onl
Each time onlySD
one
auxiliary
accepted on
in the
MCB

Make the assembled breaker trip while given signal

MX+OF must be assembled on the right, one MX+OF only

Basic type of auxiliary contact:1NO+1NC

CDB6s can't assemble MX+OF while assembled with CDB6v

Connection:1-4mm cables

Order Information
Type

Width(mm) Voltage(V)

Reference

OF

HDB6sOF

SD

HDB6sSD

MX+OF

118

AC/DC12-24V

HDB6sMX24

18

AC/DC24-48V

HDB6sMX48

18

AC110-127V

HDB6sMX110

18

AC230-400V

HDB6sMX230

048

Accessories

HDB2,HDB2LE

The sketch map of installation with breakers

Final Distribution

MX+OF

Remote Control Auxiliaries

OF

Breaker

Introductions

OF contact auxiliary

MX+OF, OF must be assembled on the left

Indicate ON or OFF state of the breaker

must
be assembled
the left
left of MCB
Each time onlyOF
one
auxiliary
accepted on
in the

Basic type of auxiliary contact:2NO+2NC


Connection: 1-4mm2 cables

Tripping Device
MX+OF shunt trip release
Indicate ON or OFF state of the breaker
Make the assembled breaker trip once got signal
Basic type of auxiliary contact:1NO+1NC
Connection: 1-4mm2 cables

Order Information
Type
OF

MX+OF

049

Width(mm) Description

Reference

18

1NO 1NC

HDB2OF11

18

2NO 2NC

HDB2OF22

18

AC/DC24V

HDB2MX24

18

AC48V~130V DC48V

HDB2MX48

18

AC230V-400V DC110V-130V HDB2MX230

Accessories

Busbar

Technical Data
IEC 60664

Material of busbar

E-CU-F25

Material of insulation

PVC

Short-circuit strength

50kA

Nominal voltage

415V

Operating voltage

Max 500V

Surge voltage

4kV

Clima stability

IEC 60068-2

Final Distribution

Standard

Order Information

U-TYPE

Type
Terminal Adaptor

Length

Reference

1.5

10

63

1m

HBB16315P

1.5

16

80

11

1m

HBB18015P

1.5

10

63

1m

HBB26315P

1.5

16

80

11

1m

HBB28015P

1.5

10

63

1m

HBB36315P

1.5

16

80

11

1m

HBB38015P

1.5

10

63

1m

HBB46315P

1.5

16

80

11

1m

HBB48015P

1.5

10

63

1m

HBB16315F

1.5

16

80

11

1m

HBB18015F

1.5

10

63

1m

HBB26315F

1.5

16

80

11

1m

HBB28015F

1.5

10

63

1m

HBB36315F

1.5

16

80

11

1m

HBB38015F

1.5

10

63

1m

HBB46315F

1.5

16

80

11

1m

HBB48015F

Reference

Dimension(mm)

Dimension(mm)

HBBA805

PIN-TYPE

Thickness Section Max.


Pole of pin
cross current(A)
(mm2) End feed-in
(mm)

Type

050

HDCH8P Modular Contactor


Standard: IEC 61095

Function

HDCH8P Modular Contactor provide:


Automatic control on equipment in buildings
Switch on or Switch off lighting or other equipments

Order Information
Final Distribution

Pole

Current (A)

2P

16
20
25
32

40

63

4P

16

20

25

32

40

63

051

Contacts

2NO
1NO 1NC
2NO
1NO 1NC
2NO
1NO 1NC
2NO
2NC
1NO 1NC
2NO
2NC
1NO 1NC
2NO
2NC
1NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC
4NO
4NC
2NO 2NC
3NO 1NC

Reference

HDCH8P16220
HDCH8P16211
HDCH8P20220
HDCH8P20211
HDCH8P25220
HDCH8P25211
HDCH8P32220
HDCH8P32202
HDCH8P32211
HDCH8P40220
HDCH8P40202
HDCH8P40211
HDCH8P63220
HDCH8P63202
HDCH8P63211
HDCH8P16440
HDCH8P16404
HDCH8P16422
HDCH8P16431
HDCH8P20440
HDCH8P20404
HDCH8P20422
HDCH8P20431
HDCH8P25440
HDCH8P25404
HDCH8P25422
HDCH8P25431
HDCH8P32440
HDCH8P32404
HDCH8P32422
HDCH8P32431
HDCH8P40440
HDCH8P40404
HDCH8P40422
HDCH8P40431
HDCH8P63440
HDCH8P63404
HDCH8P63422
HDCH8P63431

HDCH8P Modular Contactor


Standard: IEC 61095

Technical information
IEC 61095

Ambient Temperature

540

Rated Voltage Ue

230V AC

Rated Insulation Voltage Ui

500V AC

Operation Time

30000 times

Final Distribution

Standard

Coil Voltage (Us)

220/230V AC

Type

AC-7a

AC-7b

Rated Current (Ie)

20A/25A/32A/40A/63A

7A/8.5A/12A/15A/25A

Rated Power

4kW/5.4kW/6.5kW/
8.4kW/13kW

1.2kW/1.5kW/1.9kW/
2.4kW/3.8kW

Operation Frequency

1200times/h

30time/h

Marking & Breaking


Capacity

1.5Ie

8Ie

052

HDCH8P Modular Contactor


Standard: IEC 61095

Overall Dimensions
HDCH8P-2P, 16-25A

Final Distribution

17.5

HDCH8P-2P, 32-63A

35

HDCH8P-4P, 16-25A

35

HDCH8P-4P, 32-63A

053

HDRT8 Time Relay


Standard:IEC 60947.5

Function

CDRT8 Time Relay provide:


Disconnect Delay
Connect Delay

Order Information
Delay type

Reference

10

power delay

CDRT810B

120

power delay

CDRT8120B

480

power delay

CDRT8480B

480

off delay

CDRT8480A

Final Distribution

Limit delay time

Technical Data
Building Control Command Devices

CDRT8 Time Relay

Standard

IEC 60947.5

Rated Voltage Ue

230V AC

Rated Current(le)

5A

Delay Type

Off dalay
Power delay
10s 120s 480s

Limit Delay Time


th

Conventional Thermal Current(l )

8A

Timing Range

Contact Type

Normally open contact

Contact Number

Rated Control Supply Voltage(Us)

230V AC

Operating Voltage Range

85%-110%Us

Electrical Durability

30000 times

Rated Wattage

1W

Insulation Resistance

To each:AC 1760V 5s

Insulation Strength

Disconnect between the


contact position:AC 1000V 1min
Connection

up to 1mm2 cables

054

HDRT8 Time Relay


Standard:IEC 60947.5

Wiring Diagram

Final Distribution

Overall Dimensions
19max

055

HDY1 Surge Protective Devices


Standard: IEC61643

Function

HDY1 surge protective devices provide:


Applicable to household appliances and the like to offer protection
When there is an over-voltage caused by either lightning strike or operation in the circuit

Imax
(kA)
20

40

60

80

100

Uc
(V)

Up
(kV)

Final Distribution

Order Information
Reference
1P

2P

3P

4P

1P+N

3P+N

275

1.3

HDY1201275

HDY1202275

HDY1203275

HDY1204275

HDY1205275

HDY1206275

385

1.5

HDY1201385

HDY1202385

HDY1203385

HDY1204385

HDY1205385

HDY1206385

420

1.8

HDY1201420

HDY1202420

HDY1203420

HDY1204420

HDY1205420

HDY1206420

275

1.5

HDY1401275

HDY1402275

HDY1403275

HDY1404275

HDY1405275

HDY1406275

385

1.8

HDY1401385

HDY1402385

HDY1403385

HDY1404385

HDY1405385

HDY1406385

420

2.0

HDY1401420

HDY1402420

HDY1403420

HDY1404420

HDY1405420

HDY1406420

275

1.8

HDY1601275

HDY1602275

HDY1603275

HDY1604275

HDY1605275

HDY1606275

385

2.2

HDY1601385

HDY1602385

HDY1603385

HDY1604385

HDY1605385

HDY1606385

420

2.5

HDY1601420

HDY1602420

HDY1603420

HDY1604420

HDY1605420

HDY1606420

275

2.0

HDY1801275

HDY1802275

HDY1803275

HDY1804275

HDY1805275

HDY1806275

385

2.2

HDY1801385

HDY1802385

HDY1803385

HDY1804385

HDY1805385

HDY1806385

420

2.5

HDY1801420

HDY1802420

HDY1803420

HDY1804420

HDY1805420

HDY1806420

275

2.2

HDY11001275

HDY11002275

HDY11003275

HDY11004275

HDY11005275

HDY11006275

385

2.5

HDY11001385

HDY11002385

HDY11003385

HDY11004385

HDY11005385

HDY11006385

420

2.5

HDY11001420

HDY11002420

HDY11003420

HDY11004420

HDY11005420

HDY11006420

056

HDY1 Surge Protective Devices


Standard: IEC61643

Technical Data

Final Distribution

Type
Pole
Nominal discharge
current In(8/20us) kA
Maximum discharge current
Imax(8/20us) kA
Maximum continuous
operational voltage Uc V
Protection level Up kV
Leakage current
(75%Uc 1mA) uA
Response time ns
Standard: IEC 61643
Certification: SEMKO, CB

Overall Dimensions

HDY1-20 40 60

057

HDY1-20
10
20

HDY1-40

HDY1-60

HDY1-80

1P, 1P+N, 2P, 3P, 3P+N, 4P


30
40
20
40

60

80

HDY1-100
50
100

275 385 420 275 385 420 275 385 420 275 385 420 275 385 420
1.3

1.5 1.8

20
25

1.5 1.8 2.0 1.8 2.2 2.5 2.0 2.2 2.5 2.2 2.5

2.5

HDPZ50 Series Consumer Box


Standard: IEC60439-1 IEC60670

Function

HDPZ50 series Consumer Box provide:


Protection against overload
Protection against over voltage
Protection against leakage

Order Information
Installation
Surface installation

Flush installation

Material
Full Plastic

Installation
Surface installation

Flush installation

Full Plastic
Non

Surface installation

Flush installation

No.of loop
6
8
12
16
20
24
6
8
12
16
20
24

Reference
HDPZ50M6
HDPZ50M8
HDPZ50M1 2
HDPZ50M1 6
HDPZ50M20
HDPZ50M24
HDPZ50R6
HDPZ50R8
HDPZ50R1 2
HDPZ50R1 6
HDPZ50R20
HDPZ50R24

No.of loop
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36
4
6
8
12
15
18
24
36

Reference
HDPZ50PM41P30F
HDPZ50PM61P30F
HDPZ50PM8IP30F
HDPZ50PM121P30F
HDPZ50PM151P30F
HDPZ50PM18IP30F
HDPZ50PM24IP30F
HDPZ50PM36IP30F
HDPZ50PR41P30F
HDPZ50PR61P30F
HDPZ50PR8IP30F
HDPZ50PR121P30F
HDPZ50PR151P30F
HDPZ50PR18IP30F
HDPZ50PR24IP30F
HDPZ50PR36IP30F
HDPZ50PM41P30NF
HDPZ50PM61P30NF
HDPZ50PM8IP30NF
HDPZ50PM121P30NF
HDPZ50PM151P30NF
HDPZ50PM18IP30NF
HDPZ50PM24IP30NF
HDPZ50PM36IP30NF
HDPZ50PR41P30NF
HDPZ50PR61P30NF
HDPZ50PR8IP30NF
HDPZ50PR121P30NF
HDPZ50PR151P30NF
HDPZ50PR18IP30NF
HDPZ50PR24IP30NF
HDPZ50PR36IP30NF

Final Distribution

Material
Metal box&Plastic Cover

058

HDPZ50 Series Consumer Box


Standard: IEC60439-1 IEC60670

Technical Data

Final Distribution

Type

HDPZ50

HDPZ50P

Material

Box:Metal, Cover:Plastic

Full Plastic

Fire-resistancy

Fire-resistancy

Optional

Protection grade

IP30

Rated operation voltage

230/400V

Rated insulated voltage

500V

Rated operating current

100A

Withstand current

6kA

Surface installation

Overall Dimensions

Unit:mm

HDPZ50

Flush installation

Metal box&Plastic

Surface installation

Flush installation

Thickness

Cover
6

A
171

B
220

A
163

B
200

C
90

207

220

199

200

90

12

279

220

272

200

90

16

351

220

343

200

90

20

423

220

413

200

90

24

303

383

282

364

90

HDPZ50P
Full plastic
Loop
number

Flush installation

B
C C1

Surface installation

I
D

F
E

059

HJXF Metal Enclosure


Standard: EN60529

Function
Order Information
Type

Thickness of
iron charge(mm)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.5
1.5
1.5
1.5
1.5

Dimension(mm)
Installation

Overall
H
250
300
300
300
300
400
400
500
500
500
600
600
600
600
600
600
700
700
700
800
800
1000
1000
1000

W
200
250
250
300
300
300
300
400
400
400
400
400
400
500
500
500
500
500
500
600
600
800
800
800

D
140
140
180
140
200
140
200
250
140
200
250
140
200
250
140
160
200
250
200
250
250
200
250
300

H1
B1
290 150
340
200
340
200
340
250
340
250
440
250
440
250
540
350
540
350
540
350
640
350
640
350
640
350
640
450
640
450
640
450
740
450
740
450
740
450
840
550
840
550
1040 750
1040 750
1040 750

H6
170
220
220
220
220
320
320
420
420
420
520
520
520
520
520
520
620
620
620
720
720
920
920
920

Mounting
B6
158
208
208
258
258
258
258
358
358
358
358
358
358
458
458
458
458
458
458
558
558
758
758
758

Thick
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.5
1.5
1.5
1.5
1.5

Lock

Reference

1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

HJXF252014B
HJXF302514B
HJXF302518B
HJXF303014B
HJXF303018B
HJXF403014B
HJXF403020B
HJXF504014B
HJXF504020B
HJXF504025B
HJXF604014B
HJXF604020B
HJXF604025B
HJXF605014B
HJXF605020B
HJXF605025B
HJXF705016B
HJXF705020B
HJXF705025B
HJXF806020B
HJXF806025B
HJXFl008020B
HJXFl008025B
HJXFl008030B

060

Final Distribution

HJXF252014 lP43 Improved


HJXF302514 lP43 Improved
HJXF302518 lP43 Improved
HJXF303014 lP43 Improved
HJXF303018 lP43 Improved
HJXF403014 lP43 Improved
HJXF403020 lP43 Improved
HJXF504014 lP43 Improved
HJXF504020 lP43 Improved
HJXF504025 lP43 Improved
HJXF604014 lP43 Improved
HJXF604020 lP43 Improved
HJXF604025 lP43 Improved
HJXF605014 lP43 Improved
HJXF605020 lP43 Improved
HJXF605025 lP43 Improved
HJXF705016 lP43 Improved
HJXF705020 lP43 Improved
HJXF705025 lP43 Improved
HJXF806020 lP43 Improved
HJXF806025 lP43 Improved
HJXF1008020 lP43 Improved
HJXF1008025 lP43 Improved
HJXF1008030 lP43 Improved

HJXF Metal Enclosure provide:


Control, monitering, measurement and protection for the electric power loops and main power
controlling equipment.

HJXF Metal Enclosure


Standard: EN60529

Technical Data

Final Distribution

Type

HJXF IP43 Improved

Protection grade

IP43

Standard:

EN60529

Certificate

CE

Rated voltage

220/400V

Rated insulated voltage

660V

Rated operating current

400A

Withstand current

15kA

Sheet thickness

1.0~1.5mm

Mounting plate thickness

1.0~1.5mm

Hinge

Enhanced

Sealing rubber gasket

Black rubber gasket

Cable gland

bottom only

Overall Dimensions

Unit: mm

sealing rubber gasket

sealing rubber gasket

handle lock

wall fixing bracket

door
box

061

hinge

Molded Case Circuit Breaker & Air Circuit Breaker


Product Overview

Molded Case Circuit Breaker

HDM6s

063

HDM1

086
Low-voltage Distribution

Current: 16-800A
Breaking Capacity: L,S,M,T

HDM6L
Current: 40-630A
Breaking Capacity: L,M

103

Current: 10-1250A
Breaking Capacity: L,M

HDM1LE

112

Current: 16-400A
Breaking Capacity: L,M

Air Circuit Breaker

HDW9
Current: 630~6300A
Voltage: 400/415V, 690V

120

HDW6

169

Current: 200~6300A
Voltage: 400V

062

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Order Information
Type

Pole In A

HDM6s-63

Low-voltage Distribution

HDM6s-100

HDM6s-250

063

Fixed Thermal Magnetic


L-type

Thermo-adjustable

S-Type

M-type

T-Type

M-type
-

10

HDM6s063L0103XXXF HDM6s063S0103XXXF HDM6s063M0103XXXF HDM6s063T0103XXXF

16

HDM6s063L0163XXXF HDM6s063S0163XXXF HDM6s063M0163XXXF HDM6s063T0163XXXF

20

HDM6s063L0203XXXF HDM6s063S0203XXXF HDM6s063M0203XXXF HDM6s063T0203XXXF

25

HDM6s063L0253XXXF HDM6s063S0253XXXF HDM6s063M0253XXXF HDM6s063T0253XXXF

32

HDM6s063L0323XXXF HDM6s063S0323XXXF HDM6s063M0323XXXF HDM6s063T0323XXXF

40

HDM6s063L0403XXXF HDM6s063S0403XXXF HDM6s063M0403XXXF HDM6s063T0403XXXF

50

HDM6s063L0503XXXF HDM6s063S0503XXXF HDM6s063M0503XXXF HDM6s063T0503XXXF

63

HDM6s063L0633XXXF HDM6s063S0633XXXF HDM6s063M0633XXXF HDM6s063T0633XXXF

10

HDM6s063M0104XXXF HDM6s063T0104XXXF

16

HDM6s063M0164XXXF HDM6s063T0164XXXF

20

HDM6s063M0204XXXF HDM6s063T0204XXXF

25

HDM6s063M0254XXXF HDM6s063T0254XXXF

32

HDM6s063M0324XXXF HDM6s063T0324XXXF

40

HDM6s063M0404XXXF HDM6s063T0404XXXF

50

HDM6s063M0504XXXF HDM6s063T0504XXXF

63

HDM6s063M0634XXXF HDM6s063T0634XXXF

16

HDM6s100L0163XXXF HDM6s100S0163XXXF

20

T-Type
-

HDM6s100M0163XXX3 HDM6s100T0163XXX3

HDM6s100L0203XXXF HDM6s100S0203XXXF

25

HDM6s100L0253XXXF HDM6s100S0253XXXF

32

HDM6s100L0323XXXF HDM6s100S0323XXXF

40

HDM6s100L0403XXXF HDM6s100S0403XXXF

50

HDM6s100L0503XXXF HDM6s100S0503XXXF

63

HDM6s100L0633XXXF HDM6s100S0633XXXF

80

HDM6s100L0803XXXF HDM6s100S0803XXXF

100 HDM6s100L1003XXXF HDM6s100S1003XXXF

HDM6s100M1003XXX3 HDM6s100T1003XXX3

HDM6s100M0253XXX3 HDM6s100T0253XXX3
-

HDM6s100M0403XXX3 HDM6s100T0403XXX3
-

HDM6s100M0633XXX3 HDM6s100T0633XXX3
-

16

HDM6s100M0164XXX3 HDM6s100T0164XXX3

25

HDM6s100M0254XXX3 HDM6s100T0254XXX3

40

HDM6s100M0404XXX3 HDM6s100T0404XXX3

63

HDM6s100M0634XXX3 HDM6s100T0634XXX3

100

HDM6s100M1004XXX3 HDM6s100T1004XXX3

125 HDM6s250L1253XXXF HDM6s250S1253XXXF


160 HDM6s250L1603XXXF HDM6s250S1603XXXF

HDM6s250M1253XXX3 HDM6s250T1253XXX3

HDM6s250M1603XXX3 HDM6s250T1603XXX3

180 HDM6s250L1803XXXF HDM6s250S1803XXXF


200 HDM6s250L2003XXXF HDM6s250S2003XXXF

225 HDM6s250L2253XXXF HDM6s250S2253XXXF


250 HDM6s250L2503XXXF HDM6s250S2503XXXF

HDM6s250M2503XXX3 HDM6s250T2503XXX3

100 HDM6s250L1003XXXF HDM6s250S1003XXXF

HDM6s250M2003XXX3 HDM6s250T2003XXX3
-

125

HDM6s250M1254XXX3 HDM6s250T1254XXX3

160

HDM6s250M1604XXX3 HDM6s250T1604XXX3
HDM6s250M2004XXX3 HDM6s250T2004XXX3
HDM6s250M2504XXX3 HDM6s250T2504XXX3

200

250

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Order Information
Type

Pole In A

HDM6s-400 3

HDM6s-800 3

S-Type

Thermo-adjustable
M-type

T-Type

M-type

T-Type

200

HDM6s400L2003XXXF HDM6s400S2003XXXF

225

HDM6s400L2253XXXF HDM6s400S2253XXXF

250

HDM6s400L2503XXXF HDM6s400S2503XXXF

315

HDM6s400L3153XXXF HDM6s400S3153XXXF

350

HDM6s400L3503XXXF HDM6s400S3503XXXF

400

HDM6s400L4003XXXF HDM6s400S4003XXXF

200

HDM6s400L2004XXXF HDM6s400S2004XXXF

225

HDM6s400L2254XXXF HDM6s400S2254XXXF

250

HDM6s400L2504XXXF HDM6s400S2504XXXF

315

HDM6s400L3154XXXF HDM6s400S3154XXXF

HDM6s400M2503XXX3 HDM6s400T2503XXX3

HDM6s400M4003XXX3 HDM6s400T4003XXX3

HDM6s400M2504XXX3 HDM6s400T2504XXX3

350

HDM6s400L3504XXXF HDM6s400S3504XXXF

400

HDM6s400L4004XXXF HDM6s400S4004XXXF

400

HDM6s630L4003XXXF HDM6s630S4003XXXF

500

HDM6s630L5003XXXF HDM6s630S5003XXXF

HDM6s630M5003XXX3 HDM6s630T5003XXX3

630

HDM6s630L6303XXXF HDM6s630S6303XXXF

HDM6s630M6303XXX3 HDM6s630T6303XXX3

400

HDM6s630L4004XXXF HDM6s630S4004XXXF

500

HDM6s630L5004XXXF HDM6s630S5004XXXF

HDM6s630M5004XXX3 HDM6s630T5004XXX3

630

HDM6s630L6304XXXF HDM6s630S6304XXXF

HDM6s630M6304XXX3 HDM6s630T6304XXX3

400

HDM6s800L4003XXXF HDM6s800S4003XXXF

HDM6s800M4003XXXF HDM6s800T4003XXXF

500

HDM6s800L5003XXXF HDM6s800S5003XXXF

HDM6s800M5003XXXF HDM6s800T5003XXXF

HDM6s400M4004XXX3 HDM6s400T4004XXX3
-

630

HDM6s800L6303XXXF HDM6s800S6303XXXF

HDM6s800M6303XXXF HDM6s800T6303XXXF

700

HDM6s800L7003XXXF HDM6s800S7003XXXF

HDM6s800M7003XXXF HDM6s800T7003XXXF

800

HDM6s800L8003XXXF HDM6s800S8003XXXF

HDM6s800M8003XXXF HDM6s800T8003XXXF

400

HDM6s800L4004XXXF HDM6s800S4004XXXF

HDM6s800M4004XXXF HDM6s800T4004XXXF

500

HDM6s800L5004XXXF HDM6s800S5004XXXF

HDM6s800M5004XXXF HDM6s800T5004XXXF

630

HDM6s800L6304XXXF HDM6s800S6304XXXF

HDM6s800M6304XXXF HDM6s800T6304XXXF

700

HDM6s800L7004XXXF HDM6s800S7004XXXF

HDM6s800M7004XXXF HDM6s800T7004XXXF

800

HDM6s800L8004XXXF HDM6s800S8004XXXF

HDM6s800M8004XXXF HDM6s800T8004XXXF

064

Low-voltage Distribution

HDM6s-630 3

Fixed Thermal Magnetic


L-type

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Technical Data

Fixed Thermal Magnetic


Basic Information (IEC60947-2)
Frame Size
Low-voltage Distribution

3P

Number of Poles

4P

3P

4P

3P

4P

Breaking Capacity Level

Rated Ultimate Short-circuit Breaking


Capacity Icu (kA rms)

25

18

50

30

50

30

35

26

35

26

35

26

35

26

100%

75%

100%

75%

100%

Rated Service Short-circuit Breaking


Capacity Ics (kA rms)
Mechanical Durabilities
Electrical Durabilities

75% 100% 50% 100% 50% 100%

75% 100% 75%

On-off Cycle

Tripping Unit
16/20//25/32/40/
50/63/80/100

Rated Current (A)

100/125/160/180/
200/225/250

Accessory
Indication Accessories
OF
SD
Control Accessories
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Mounting & Connection
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
Connection
Spreader
Protection
Phase Barrier
Installation Information
shows it has this option;
means it has no this option.

065

See Page 74

See Page 75

See Page 76

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Technical Data

Fixed Thermal Magnetic


Basic Information (IEC60947-2)
Frame Size
Breaking Capacity Level

4P

3P

4P

3P

4P

Rated Ultimate Short-circuit Breaking


Capacity Icu (kA rms)

50

30

50

30

50

30

50

30

50

30

70

40

50

30

70

40

Rated Service Short-circuit Breaking


Capacity Ics (kA rms)

50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100%

Mechanical Durabilities
Electrical Durabilities

On-off Cycle

Tripping Unit
Rated Current (A)

200/225/250/315/
350/400

Accessory
Indication Accessories
OF
SD
Control Accessories
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Mounting & Connection
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
Connection
Spreader
Protection
Phase Barrier
Installation Information

See Page 77

See Page 78

See Page 79

shows it has this option;


means it has no this option.

066

Low-voltage Distribution

3P

Number of Poles

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Technical Data

Thermo-adjustable
Basic Information (IEC60947-2)
Frame Size
3P

Number of Poles

3P

4P

4P

3P

4P

3P

4P

Low-voltage Distribution

Breaking Capacity Level

Rated Ultimate Short-circuit Breaking


Capacity Icu (kA rms)

50

30

50

30

50

30

50

30

70

40

70

40

70

40

70

40

Rated Service Short-circuit Breaking


Capacity Ics (kA rms)

50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100% 50% 100%

Mechanical Endurance
Electrical Endurance

On-off Cycle

Tripping Unit
Rated Current (A)

16/25/40/63/100

125/160/200/250

250/400

See Page 76

See Page 77

500/630

Thermo-adjustable Setting (Ir)


Accessory
Indication Accessories
OF
SD
Control Accessories
MX(AC400, 230V, DC220V)
MN (AC400, 230V)
Extended Rotary Handle (Round and Square)
AC Motor Mechanism (AC400, 230V)
Mechanical Interlock
Mounting & Connection
Fixed, Front Connection
Fixed, Rear Connection
Plug-in, Rear Connection
Plug-in, Front Connection
Drawer-out, Rear Connection
Connection
Spreader
Protection
Phase Barrier
Installation Information
shows it has this option;
means it has no this option.

067

See Page 75

See Page 78

HDM6s Molded Case Circuit Breaker

Standard: IEC 60947-2

Basic Technical Data


Rated Insulation Voltage Ui: AC 800V (Frame 63AF: AC 690V)
Rated Impulse Withstand Voltage Uimp: 8KV (Frame 63AF: 6KV)
Rated Working Voltage Ue: AC 415V (Frame 63AF: AC 400)
Rated Working Frequency: 50Hz/60Hz
Utilization Category: A
Isolation Function: Applicable for all series

Complete Functions and Accessories


Low-voltage Distribution

Spreader

MX

Plug-in Rear Connection

Phase Barrier

MN

Fixed Rear Connection

AC Motor Mechanism

Plug-in Connecting Terminal

Mechanical Interlock

Round Extended Rotary Handle

Plug-in Front Connection

SD

Square Extended Rotary Handle

Drawer-out Rear Connection

OF

068

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Complete Functions
Optional Tipping Unit Functions
The tripping unit is the intelligent part of the moulded case circuit breaker.
HDM6s Thermal Magnetic Tripping Unit is divided into 2 types, that is, Fixed Rating and Thermaladjustable Tripping Unit.

Fixed Thermal Magnetic Tripping Unit


Low-voltage Distribution

Be used for overload and short-circuit protection.

Thermal-adjustable, Fixed-magnetic Tripping Unit


Be used for overload and short-circuit protection
Adjustable overload current
Change the relation between the overload current and the rated current by adjusting the
grades of the knobs (0.8-0.9-1.0In, three grades are available to be adjusted). Even so the
current of instantaneous protection movement shall still take the rated current as the base
number
E.g.: The customers need 250AF, 200A current MCCB, and considering the product expansion in
the future, it is required to select the circuit breaker with overload adjustable feature. So which kind
of the product should the customers choose, how much is it for overload tripping release current
(Ir1) and instantaneous tripping release current (Ii)?
Answer: HDM6s, 250AF, M-Type Breaking Capacity, Rated Current 250A, and switch the knob in
the grade of 0.8.
So, Ir1=250A * 0.8=200A, Ii=250 * 10=2500A.

HDM6s All Series of Products Featuring Isolation Function


The circuit breaker with isolation function shall meet the standard of IEC 60947-2.
The operating handle hasnt indicated OFF position until the contact has been indeed opened.
The Isolation Function Protection includes:
Mechanical reliability of the contact indication system
No leakage current
Over-voltage Withstand Capacity between outlet and inlet terminals

069

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6 Series


Indicating Accessories
Auxiliary Contact (OF):
be connected in the auxiliary circuit of switch device and used for the accessories to indicate the
position of the circuit breaker contacts

Alarm Switch (SD):


be used for the accessories under the state of on and off or trip of the indication circuit breaker for

Accessory
Name

Switch-on/off

Tripping

Switch-on/off

Tripping

Low-voltage Distribution

the following 5 reasons:


Overload or short-circuit fault
Residual earth-leakage fault
Artificial Testing Release
Shunt Trip Release
Line Fault and Under-voltage Release Tripping

OF
Accessory
Name
SD

Electrical Parameter of OF & SD


Rated Thermal Current (A)
Utilization Category
Working Current 50Hz/60Hz

Control Accessories
Under-voltage Release (MN)
Tripping threshold between 0.35 and 0.7 times the rated voltage; when it is at 85%-110% of rated
working voltage, Under-voltage Release shall ensure the circuit breaker switch-on; when the
rated working voltage is less than 35%, Undervoltage Release shall prevent switch-on of the
circuit breaker.

Undervoltage Release Wiring


Ue

Applicable Type of
Circuit Breaker

Power Consumption of Under-voltage Coil (W)

HDM
HDM
HDM
HDM
HDM
HDM

070

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6 Series

Low-voltage Distribution

071

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6 Series

Low-voltage Distribution

072

HDM6s Molded Case Circuit Breaker

Standard: IEC 60947-2

Installation Location of Accessories


Installation Method for Tripping Release and Accessories Code

Alarm Switch

Lead Direction
Installation
at Left Side

Auxiliary Contact

Shunt Release

Under-voltage
Release

Installation
at Right Side

Handle
Low-voltage Distribution

Name of Accessory

Product Type
HDM6s63/100/250

Alarm Switch

Shunt Release

Auxiliary Contact

Undervoltage Release
Auxiliary Contact
Shunt Release
Shunt Release
Undervoltage Release
Auxiliary Contact
Undervoltage Release
Shunt-trip Release
Alarm Switch
Undervoltage Release
Alarm Switch
Shunt Release
Auxiliary Contact
Alarm Switch
Auxiliary Contact
Undervoltage Release
Alarm Switch

073

HDM6s400

HDM6s630

HDM6s800

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s63 Installation Dimension


Chart of Fixed Front Connection Installation Hole

3.5

25

M5*14

(3-pole no size)

117

25

Installation Dimension of Fixed Front Connection

Low-voltage Distribution

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Fixed Rear Connection Installation Hole


L=S/M=T
25

25 (3-pole no size)

25

25

25

117

7
3.5

Chart of Terminal Connection


Installation Hole
M5*14

117

(3-pole no size)

Fixed Rear Connection Wiring

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Plug-in Rear Connection Wiring

Chart of Plug-in Rear Connection


Installation Hole

074

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s100 Installation Dimension


Chart of Fixed Front Connection Installation Hole

Installation Dimension of Fixed Front Connection


M8*16

30

4.5

30

129

(3-pole no size)

L=S/M=T

Chart of Fixed Rear Connection Installation Hole

30 (3-pole no size)

30

30

30

132

(3-pole no size)

12
4.5

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Plug-in Rear Connection


Installation Hole

075

Chart of Terminal Connection


Installation Hole

7.5

30

Fixed Rear Connection Wiring

129

Low-voltage Distribution

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Plug-in Rear Connection Wiring

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s250 Installation Dimension


Chart of Fixed Front Connection Installation Hole

Installation Dimension of Fixed Front Connection


M8*16

4.5
35

35

126

(3-pole no size)

Low-voltage Distribution

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Fixed Rear Connection Installation Hole

Fixed Rear Connection Wiring

L=S/M=T

Chart of Terminal Connection


Installation Hole
35

35 (3-pole no size)

35

35

35

144

14
4.5

126

(3-pole no size)

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Plug-in Rear Connection Wiring

Chart of Plug-in Rear Connection Installation Hole

076

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Low-voltage Distribution

077

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s630 Installation Dimension


Chart of Fixed Front Connection Installation Hole

Installation Dimension of Fixed Front Connection


M12*40

5.5
58

58

200

(3-pole no size)

Low-voltage Distribution

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Fixed Rear Connection


Installation Hole
L=S/M=T
58

58

58

58

58

Fixed Rear Connection Wiring

40

Chart of Terminal Connection


Installation Hole

5.5

200

234

(3-pole no size)

(3-pole no size)

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Plug-in Rear Connection


Installation Hole

Plug-in Rear Connection Wiring

078

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s800 Installation Dimension


Chart of Fixed Front Connection Installation Hole

70

Installation Dimension of Fixed Front Connection

5.5

70

M12*40

243

(3-pole no size)

Chart of Fixed Rear Connection Installation Hole


L=S/M=T
70

70 (3-pole no size)

70

70

Fixed Rear Connection Wiring


70

40

16 12

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Chart of Plug-in Rear Connection


Installation Hole

079

Chart of Terminal Connection


Installation Hole

5.5

243

(3-pole no size)

243

Low-voltage Distribution

Remark: X-X, Y-Y is the center of 3-pole


circuit breaker

Plug-in Rear Connection Wiring

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Plug-in Front Connection Installation Dimension (HDM6s100 and HDM6s250)


Equipped with
Circuit Breaker

Pole
No.

Appearance and Installation Dimension (mm)

HDM6s100

HDM6s250

Pole
No.

Appearance and Installation Dimension (mm)


Low-voltage Distribution

Equipped with
Circuit Breaker
HDM6s100

HDM6s250

Drawer-out Rear Connection Base (HDM6s400, HDM6s630 and HDM6s800)


Equipped with
Circuit Breaker

Pole
No.

Appearance Dimension (mm)

Installation
Dimension

HDM6s400
Wire connection
behind board

HDM6s630

HDM6s800

080

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s 63A-800A Fixed and Plug-in Circuit Breaker Connection Hole-opening Dimension
Type of Circuit
Breaker

Pole
No.

Exposure of Front Cover and


Pull-out Handle

Exposure of Pull-out
Handle Only

Low-voltage Distribution

Safety Distance
Type of Circuit Breaker

Length of Exposed
Conductor +B

Remark: no matter whether the products have the accessories, the distance between
the products must meet the requirements of C distance.

Installation Dimension
Motor Mechanism

AC Motor Mechanism

Make
Trip
Break
Manual
Motor Auto

081

Type of Circuit Breaker

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

HDM6s63-800 Frame (3P) Mechanical Interlock Dimension


Type of Circuit
Breaker

Breaking
Capacity Level
L,S
M,T
L,S
M,T
L,S
M,T
L/S/M/T
L/S/M/T
Low-voltage Distribution

L/S/M/T
HDM6s63-800 Frame Extension Rotary Handle Base Dimension
Type of Circuit
Breaker

Remark: the shortest distance of G connecting rod is 50 mm, and ex-factory standard
configuration is 150mm, please contact the factory, if the special customization is required.
HDM6s63-800 Frame Extension Rotary Handle

Round
53

65
36

200 compare to hinge


32

HDM6s63, HDM6s100 and HDM6s250 is 65 or 95 for option, the default value is 65.
HDM6s400, HDM6s630 and HDM6s800 is 95 or 125 for option, the default value is 95.

Square
65

4.5

65

80

80

94

80

80

42

200 compare to hinge

082

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Impact of High Temperature on Tipping Release Performance


When environmental temperature is over 40C, small changes have taken place on overload
protection properties. In tripping release time /current curve, the Ir setting value of the circuit breaker
must be corrected as per the following factors.
Ambient Temperature C

Low-voltage Distribution

Type of Circuit
Breaker

40

45

50

55

60

HDM6s 63

0.94

0.88

0.80

0.72

HDM6s 100

0.95

0.89

0.84

0.76

HDM6s 250

0.95

0.91

0.87

0.82

HDM6s 400

0.94

0.87

0.81

0.73

HDM6s 630

0.93

0.88

0.83

0.76

HDM6s 800

0.88

0.83

0.79

0.76

40C
30C
20C

Impact of Altitude on Tipping Release Performance


There is no impact on the performance of the circuit breaker when the height is below 2000m. But
when it is over 2000m, the falling factors as air insulation properties and cooling capability shall
be considered; the correction factors given in the table below are applicable for the conditions of
the height for the installation over 2000m, the breaking capacity of the circuit breaker remains
unchanged.
Altitude (m)
Max.Working Voltage (V)
30C Thermal Rated Value (A)
Average Isolation Voltage (V)
Dielectric Strength (V)

3-Pole (W) Total Power Loss


Type of Circuit
Breaker
HDM6s 63
HDM6s 100
HDM6s 250
HDM6s 400
HDM6s 630
HDM6s 800

083

Power-up
Current

Front Connection
Wiring (Standard)

Rear Connection
Wiring

Plug-in Wiring

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Tripping Release Curve


HDM6s63 10A-63A, the black line is used for the distribution.

HDM6s100 63A-100A, the black line is used for the distribution.

Instantaneous current range:


10In 20%

Low-voltage Distribution

Instantaneous current range:


10In 20%

HDM6s100 16A-50A, the black line is used for the distribution.

Instantaneous current range:


10In 20%

HDM6s250 100A-250A, the black line is used for the distribution.

Instantaneous current range:


10In 20%

084

HDM6s Molded Case Circuit Breaker


Standard: IEC 60947-2

Tripping Release Curve


HDM6s400 200A-400A, the black line is used for the power
distribution.

HDM6s630 400A-630A is used for the power distribution.

Low-voltage Distribution

Instantaneous current range:


10In 20%

Instantaneous current range:


10In 20%

HDM6s800 400A-630A is used for the power distribution.


5 000

5 000

2 000
1 000
500

2 000
1 000
500

200
100
50

200
100
50

20
10
5

20
10
5

2
1
.5

2
1
.5

.2
.1
.05

Instantaneous current range:


10In 20%

.2
.1
.05

.02
.01
.005

.02
.01
.005

.002
.001
.5 .7 1

.002
.001
.5 .7 1

3 4 5 7 10

I/Ir
085

HDM6s800 700A-800A is used for the power distribution.

20 30 50 70100 200 300

Instantaneous current range:


6In 20%

3 4 5 7 10

I/Ir

20 30 50 70100 200 300

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Coding System

name

Frame size B.C Rate Current

HDM6L

100

100

L:L 40,50,
100:100AF
type 63,80,100

Pole

Accessory

Voltage of Accessory

Residual current

3P

3:3P

F:fix-type
in front of the board

M:MX

N:AC230V;intenal accessory AC230V;


Leakage module AC230V

T:100/300/500mA
R:fix-type
(100AF, 250AF,
behind the board
400AF, 630AF)

O:OF

D:DC24V

F:300/500/1000mA P:insert-type
(400AF, 630AF)
behind the board

N:MN

1:Internal accessory AC400V;


Leakage module AC230V

F:OF+OF

2: Internal accessory AC230V;Leakage module


AC400V

S:SD

3:Internal accessory DC24V;Leakage module AC400V

D:OF+S

4:Internal accessory DC24V;Leakage module AC230V

Low-voltage Distribution

Y:30/100/500mA
(100AF, 250AF)

X:No Accessory

A:4P A Type
100.125.
M:M
N phase is not equipped with overcurrent trip component
250:250AF
160.180.200.
type
and N phase is always connected.
225.250
The N phase does not open/close with the other 3 poles.
B: 4P B Type
200.225.
N phase is not equipped with overcurrent trip
400:400AF
250.315.
component, and N phase opens/closes with the other
350.400
3 poles. (N phase closes first and then opens)
C: 4P C Type
N phase is equipped with overcurrent trip component, and
630:630AF
400.500.630
N phase always opens/closes with the other 3 poles .
(N phase closes first and then opens)
D: 4P D Type
N phase is equipped with overcurrent trip component
and N phase is always connected.
The N phase does not open/close with the other 3 poles

Installation method

X:AC400V;NO Accessory voltage;


Leakage module voltage AC400V

U:Leakage alarm without action module


I:Leakage alarm with action module
A:MX+Leakage alarm without action module
1:MX+Leakage alarm with action module
B:OF+Leakage alarm without action module
2:OF+Leakage alarm with action module
C:MN+Leakage alarm without action module
3:MN+Leakage alarm with action module
E:OF+OF+Leakage alarm without action module
4:OF+OF+Leakage alarm with action module
G:SD+Leakage alarm without action module
5:SD+Leakage alarm with action module
H:OF+SD+Leakage alarm without action module

Order Information
Type

HDM6L-100

6:OF+SD+Leakage alarm with action module

Pole
3

HDM6L-250

HDM6L-400

HDM6L-630

In A
40
50
63
80
100
40
50
63
80
100
100
125
160
180
200
225
250
100
125
160
180
200
225
250
200
225
250
315
350
400
200
225
250
315
350
400
400
500
630
400
500
360

L-type
HDM6L100L403XX*F
HDM6L100L503XX*F
HDM6L100L633XX*F
HDM6L100L803XX*F
HDM6L100Ll003XX*F
HDM6L100L404XX*F
HDM6L100L504XX*F
HDM6L100L634XX*F
HDM6L100L804XX*F
HDM6L100Ll004XX*F
HDM6L250L1003XX*F
HDM6L250L1253XX*F
HDM6L250L1603XX*F
HDM6L250L1803XX*F
HDM6L250L2003XX*F
HDM6L250L2253XX*F
HDM6L250L2503XX*F
HDM6L250L1004XX*F
HDM6L250L1254XX*F
HDM6L250L1604XX*F
HDM6L250L1804XX*F
HDM6L250L2004XX*F
HDM6L250L2254XX*F
HDM6L250L2504XX*F
HDM6L400L2003XX*F
HDM6L400L2253XX*F
HDM6L400L2503XX*F
HDM6L400L3153XX*F
HDM6L400L3503XX*F
HDM6L400L4003XX*F
HDM6L400L2004XX*F
HDM6L400L2254XX*F
HDM6L400L2504XX*F
HDM6L400L3154XX*F
HDM6L400L3504XX*F
HDM6L400L4004XX*F
HDM6L630L4003XX*F
HDM6L630L5003XX*F
HDM6L630L6303XX*F
HDM6L630L4004XX*F
HDM6L630L5004XX*F
HDM6L630L6304XX*F

M-type
HDM6L100M403XX*F
HDM6L100M503XX*F
HDM6L100M633XX*F
HDM6L100M803XX*F
HDM6L100M1003XX*F
HDM6L100M404XX*F
HDM6L100M504XX*F
HDM6L100M634XX*F
HDM6L100M804XX*F
HDM6L100M1004XX*F
HDM6L250M1003XX*F
HDM6L250M1253XX*F
HDM6L250M1603XX*F
HDM6L250M1803XX*F
HDM6L250M2003XX*F
HDM6L250M2253XX*F
HDM6L250M2503XX*F
HDM6L250M1004XX*F
HDM6L250M1254XX*F
HDM6L250M1604XX*F
HDM6L250M1804XX*F
HDM6L250M2004XX*F
HDM6L250M2254XX*F
HDM6L250M2504XX*F
HDM6L400M2003XX*F
HDM6L400M2253XX*F
HDM6L400M2503XX*F
HDM6L400M3153XX*F
HDM6L400M3503XX*F
HDM6L400M4003XX*F
HDM6L400M2004XX*F
HDM6L400M2254XX*F
HDM6L400M2504XX*F
HDM6L400M3154XX*F
HDM6L400M3504XX*F
HDM6L400M4004XX*F
HDM6L630M4003XX*F
HDM6L630M5003XX*F
HDM6L630M6303XX*F
HDM6L630M4004XX*F
HDM6L630M5004XX*F
HDM6L630M6304XX*F

Note:* express residual current

086

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Technical Date
Thermo-adjustable
Basic Information(IEC60947-2)
Frame Size AF
Low-voltage Distribution

100

Number of Poles

250

3P

Breaking Capacity Level

4P
M

400

3P

4P

630

3P

4P

3P

4P

Rated Ultimate Shortcircuit Breaking


Capacity Icu(kA rms)

35

50 35

50

35

50

35

50

50

70

50

70

50

70

50

70

Rated Service Short-circuit Breaking


Capacity Ics(kA rms)

22

30 22

30

22

30

22

30

30

40

30

40

30

40

30

40

Mechanical Endurance
ElectricaI Endurance

8500

7000

4000

4000

1500

1000

1000

1000

40/50/63/80/100

100/125/160/180/
200/225/250

200/225/250/315/
350/400

400/500/630

OF

SD

MX(AC400,230V,DC220V)

MN(AC400,230V)

Extended Rotary Handle(Round and Square)

AC Motor Mechanism(AC400,230V)

Fixed,Rear Connection

Plug-in,Rear Connection

See Page 94

See Page 95

See Page 96

See Page 97

On-0ff Cycle

Tripping Unit
Rated Current(A)

In

Accessory
Indication Accessories

Control Accessories

Mounting&Connection

Connection
Spreader
Protection
Phase Barrier
Installation Information
"" shows it has this option

087

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Basic Technical Data


Rated Insulation Voltage Ui,AC 800V
Rated Impulse Withstand Voltage Uimp,8KV
Rated Working Voltage Ue,AC 400V
Rated Operational Frequency,50Hz
Utilization Category,A

Low-voltage Distribution

Complete Functions and Accessories


1

Spreader

MX

11

SD

Phase Barrier

MN

12

OF

AC Motor Mechanism

Leakage Module
(Can't order separately)

Round Exended Rotary Handle

Plug-in Rear Connection

Square Exended Rotary Handle

10

Fixed Rear Connection

088

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Trip unit function


Except the basic features of overload and short circuit protection, the HDM6L residual current
protecting circuit breaker can also provide indirect contact protection for people and prevent fire
accident due to damaged insulation and defective grounding current. The circuit breaker can also add
functions if needed,including electricity leakage alarm.

Low-voltage Distribution

Versatile functions
The circuit breaker conforms to the latest national standards, and uses reliable 3-phase power supply
technology. If one phase is missing, i.e. there is one phase loss, the circuit breaker can still provide
reliable leakage protection.The product has wide range of voltage input. When the voltage drops to
85V due to power supply failure, the circuit breaker can still provide reliable leakage protection. The
time delay function includes non-delay mode and 3-section delay mode, which can be chosen by the
user according to residual current.
Easy operation
The testing button is easy and convenient to use. The micro-switch has sensitive contact and long
service life. The trip coil has excellent material and performance with remarkable trip indicating
button, which provides a safe and reliable operation environment for clients.

Basic parameter information


The 4-pole products with N phase are divided to four types.
A type: N phase is not equipped with overcurrent trip component and N phase is always connected.
The N phase does not open/close with the other 3 poles
B type: N phase is not equipped with overcurrent trip component, and N phase opens/closes with the
other 3 poles (N phase closes first and then opens)
C type: N phase is equipped with overcurrent trip component, and N phase always opens/closes with
the other 3 poles (N phase closes first and then opens)
D type: N phase is equipped with overcurrent trip component and N phase is always connected.
The N phase does not open/close with the other 3 poles.

Electric motor protection


HDM6L residual current protection circuit breaker with plastic case can be used for electricity
distribution protection, frame current under 400 and electric motor protection.

Isolation function
HDM6L series product has isolation protection function.The operation handle can indicate "OFF"
position only when the contact is really opened.

089

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6L Series


Indicating Accessories
Auxiliary Contact(OF):
Be connected in the auxiliary circuit of switch device and used for the accessories to indicate the
position of the circuit breaker contacts

Alarm Switch(SD):

Accessory Name

Switch-on/off

Tripping

Switch-on/off

Tripping

OF
Accessory Name

SD

Electrical Parameter of OF&SD


3A
Rated Thermal Current(A)
Utilization Category
Working Current 50Hz AC400V
DC220V

AC15

DC13

0.3A

0.15A

Control Accessories
Under-voltage Release(MN)
Tripping threshold between 0.35 and 0.7 times the rated voltage;when it is at 85%-110%of
rated working voltage,Under-voltage Release shall ensure re the circuit breaker switchon;when the rated working voltage is less than 35,Under voltage Release shall prevent
switch-on of the Circuit breaker

Applicable Type of Circuit Breaker

Power Consumption of Undervoltage Coil(W)


AC400V

AC230V

HDM6L100

3.9

3.2

HDM6L250

4.3

3.3

HDM6L400

3.6

2.5

HDM6L630

1.6

090

Low-voltage Distribution

Be used for the accessories under the state of on and off or trip of the indication circuit breaker for
the following reasons:
Overload or short-circuit fault
Residual ea rth-leakage fault
Artificial Testing Release
Shunt Trip Release
Line Fault and Under-voltage Release Tripping

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6L Series


Shunt Release(MX)
When the working voltage is between 70%-110%Us ,the shunt release shall reliably trip the
circuit breaker.
Applicable Type of Circuit Breaker

Power Consumption of Undervoltage Coil(W)

Low-voltage Distribution

AC400V

AC230V

DC24V

HDM6L100

96.8

73

91.2

HDM6L250

112

68.6

85.3

HDM6L400

67

62.3

100

HDM6L630

163

153

120

When the rated control supply voltage of the shunt release is DC24V the maximum length of the
copper conductor shall satisfy the following requirements:
Conductor Area Rated
Control Supply
Voltage(DC24V)
100%Us
85%Us

1.5mm

2.5mm

150m
100m

250m
160m

When the requirements above cannot be satisfied,it is recommended to adopt the following chart to
design control loop of the shunt release.
Shunt release

AC50Hz 230V, 400V;

Extended Rotary Handle


Function:indication of the three positions of switchon,switchoff and trip
The circuit breaker cannot be switchon when the switch board door is open
The door cannot be opened if the circuit breaker is ON
An extension shaft that can be adjusted to the distance between the back of circuit breaker and
door the specific distance refers to the dimensions at the rear and the installation part.
The OFFPosition of the circuit breaker can han9 13 locks with the diameter of 5 mm

091

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Complete Accessories of HDM6L Series


AC Motor Mechanism
Provide on-site and remote distance control circuit breaker to implement switch-on and switch-off.

Leakage Alarm module


(Alarm but Non Tripping Function: Alarm but non tripping in case of leakage reach the alarm
limitation meanwhile still in energized state )
The module indicates alarm by means of luminous diode.
As luninous diode indicates red, it means system leakage exceed setting value,and at that time,
normally open contact turn to normal close, normal closed contact trun to normal open.

Connection Accessories
Fixed, Rear Connection
It is easy to install and connect the products in the Rear Connection.

Plug-in Rear Connection


The plug-in connection for the products is easy for maintenance and replacement, but plug-in and
plug-out cannot be done with the electricity.

092

Low-voltage Distribution

Phase Barriers
The phase barriers are used to reinforce isolation of connection points in installation with bus-bars
Whether insulated or not We can easily install the phase barrier through the phase slot of the this
product.
Both the inlet and outlet line of HDM6s has phase barrier.

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

lnstallation Location of Accessories


Installation Method for Tripping Release and Accessories Code

Low-voltage Distribution

Name of Accessory

Produt Type
HDM6L100/250

Two Group

093

HDM6L400

HDM6L630

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L 100AF Installation Dimension

Low-voltage Distribution

094

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L 250AF Installation Dimension

M8*16

Low-voltage Distribution

095

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L 400AF Installation Dimension

Low-voltage Distribution

096

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L 630AF Installation Dimension

Low-voltage Distribution

097

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L EarthLeakage circuit Breaker connection Hole-opening Dimension


Type of Circuit
Breaker

HDM6L100AF

HDM6L250AF

HDM6L400AF

HDM6L100-630 4P

HDM6L630AF

Exposure of Front Cover and


Pullout Handle
W1

L1

Exposure of Pullout
Handle Only

L11

W2

L2

L21

88

42

35

60

30

3P

92

4P

122

88

42

35

60

30

3P

107

102

51

35

60

30

4P

142

102

51

35

60

30

3P

140

180

90

61

102

53

4P

184

180

90

61

102

53

3P

210

200

100

65

102

51

4P

280

200

100

65

102

51

Low-voltage Distribution

HDM6L100-630 3P

Pole
No.

Safety Distance

Type of Circuit Breaker

A(mm)

B(mm)

HDM6L100AF

60

60

HDM6L250AF

60

60

HDM6L400AF

110

110

HDM6L630AF

110

110

B1(mm)

C(mm)
30
30

Length of
Exposed
Conductor +B

70
70

Remark:no matter whether the products have the accessories,the distance between the products
must meet the requirements of C distance.

Installation Dimension
AC Motor Mechanism
Type of Circuit Breaker

HDM6L100AF

129

30

11

90

144

14

80

8.5

38.5

28.5

HDM6L250AF

126

35

11

104

138

13

80

8.5

38.5

28.5

HDM6L400AF

215

44

11

140

232

22

112

12

97.5

28.5

HDM6L630AF

243

70

11

150

260

16

112

12

97.5

28.5

098

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM6L100630 Frame Extension Rotary Handle Base Dimension

Low-voltage Distribution

Type of Circuit
Breaker

HDM6L100AF

30

51.5

51.5

54

20

HDM6L250AF

35

71.5

71.5

56

20

HDM6L400AF

44

107.5

107.5

76

20

HDM6L630AF

70

121.5

121.5

76

20

Remark: the shortest distance of G connecting rod is 50mm and ex-factory standard configuration is
150mm, please contact the factory if the special customization is required.

HDM6L100630 Frame Extension Rotary Handle

HDM6L100 and HDM6L250 is 65 or 95 for option,the default value is 65.


HDM6L400,HDM6L630 is 95 or 1 25 for option,the default value is 95.

HDM6L100/250AF

099

HDM6L400/630AF

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Impact of High Temperature on tripping Release Performance


When environmental temperature is over 40C,small changes have taken place on overload
protection properties,In tripping release time,current curve,the Ir setting value of the circuit breaker
must be corrected as per the following factors.

Height

Ambient Temperature

Type of Circuit
Breaker

35

40

45

50

HDM6L100AF

0.97

0.95

0.92

0.89

HDM6L250AF

0.98

0.97

0.95

0.94

HDM6L400AF

0.98

0.95

0.93

0.91

HDM6L630AF

0.98

0.95

0.93

0.91

Low-voltage Distribution

Temperature

30

Impact of Altitude on Tipping Release Performance


There is no impact on the performance of the circuit breaker when the height is below 2000m,But
when it is over 2000m,the falling factors as air insulation properties and cooling capability shall be
considered,the correction factors given in the table below are applicable for the conditions of the
height for the installation over 2000m,the breaking capacity of the circuit breaker remains unchanged.

Altitude(m)

2000

3000

4000

5000

415

350

310

270

30C Thermal Rated Value(A)

In

0.96In

0.93In

0.96In

Average Isolation Voltage(V)

800

700

600

500

Dielectric Strength(V)

3000

2500

2100

1800

Max.Working Voltage(V)

3-Pole (W) Total Power Loss


Type of Circuit
Breaker

Power-up Current

Front Connectuion Rear Connectuion


Wiring(Standard)
Wiring

HDM6L100AF

100A

40

50

50

HDM6L250AF

250A

63

90

90

HDM6L400AF

400A

103

110

130

HDM6L630AF

800A

200

230

290

Plug-in Wiring

100

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Tripping Release Curve


HDM6L-100 16A-50A,the black line is used for the distribution

Low-voltage Distribution

HDM6L-250

101

HDM6L-100 63A-100A,the black line is used for the distribution

HDM6L Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Tripping Release Curve


HDM6L-400 200A-400A,the black line is used for the power distribution

Low-voltage Distribution

HDM6L-630

102

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Function

HDM1 Molded case circuit breaker provide:


Provide protection for indirect contact.
To protect power line and equipments against overload, undervoltage and short-circuit faults
(In400A)
Under normal circumstances can be as infrequent line conversion and motor frequent start.

Order Information
Type
HDM1-63

In A
3P

Low-voltage Distribution

4P

HDM1-100

2P

3P

4P

103

10
16
20
25
32
40
50
63
10
16
20
25
32
40
50
63
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100

Reference
Type M
HDM163M103
HDM163M163
HDM163M203
HDM163M253
HDM163M323
HDM163M403
HDM163M503
HDM163M633
HDM163M104
HDM163M164
HDM163M204
HDM163M254
HDM163M324
HDM163M404
HDM163M504
HDM163M634
HDM1100M162
HDM1100M202
HDM1100M252
HDM1100M322
HDM1100M402
HDM1100M502
HDM1100M632
HDM1100M802
HDM1100M1002
HDM1100M163
HDM1100M203
HDM1100M253
HDM1100M323
HDM1100M403
HDM1100M503
HDM1100M633
HDM1100M803
HDM1100M1003
HDM1100M164
HDM1100M204
HDM1100M254
HDM1100M324
HDM1100M404
HDM1100M504
HDM1100M634
HDM1100M804
HDM1100M1004

Type L
HDM163L103
HDM163L163
HDM163L203
HDM163L253
HDM163L323
HDM163L403
HDM163L503
HDM163L633
-----------------HDM1100L163
HDM1100L203
HDM1100L253
HDM1100L323
HDM1100L403
HDM1100L503
HDM1100L633
HDM1100L803
HDM1100L1003
----------

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Order Information
Type
HDM1-225

In A
2P

3P

HDM1-400

3P

4P

HDM1-630

3P

4P

HDM1-800

3P

4P

HDM1-1250 3P

Low-voltage Distribution

4P

100
125
160
180
200
225
100
125
160
180
200
225
100
125
160
180
200
225
200
225
250
315
350
400
200
215
250
315
350
400
400
500
630
400
500
630
400
500
630
700
800
400
500
630
700
800
700
800
1000
1250

Reference
Type L
Type M
-HDM1225M1002
-HDM1225M1252
-HDM1225M1602
-HDM1225M1802
-HDM1225M2002
-HDM1225M2252
HDM1225L1003
HDM1225M1003
HDM1225L1253
HDM1225M1253
HDM1225L1603
HDM1225M1603
HDM1225L1803
HDM1225M1803
HDM1225L2003
HDM1225M2003
HDM1225L2253
HDM1225M2253
-HDM1225M1004
-HDM1225M1254
-HDM1225M1604
-HDM1225M1804
-HDM1225M2004
-HDM1225M2254
HDM1400L2003
HDM1400M2003
HDM1400L2253
HDM1400M2253
HDM1400L2503
HDM1400M2503
HDM1400L3153
HDM1400M3153
HDM1400L3503
HDM1400M3503
HDM1400L4003
HDM1400M4003
-HDM1400M2004
-HDM1400M2254
-HDM1400M2504
-HDM1400M3154
-HDM1400M3504
-HDM1400M4004
HDM1630M4003
HDM1630L4003
HDM1630M5003
HDM1630L5003
HDM1630M6303
HDM1630L6303
HDM1630M4004
-HDM1630M5004
-HDM1630M6304
-HDM1800M4003
HDM1800L4003
HDM1800M5003
HDM1800L5003
HDM1800M6303
HDM1800L6303
HDM1800M7003
HDM1800L7003
HDM1800M8003
HDM1800L8003
HDM1800M4004
-HDM1800M5004
-HDM1800M6304
-HDM1800M7004
-HDM1800M8004
-HDM11250M7003
-HDM11250M8003
-HDM11250M10003
-HDM11250M12503
--

Note: The connection mode for HDM1 is the fixed type front connection.

104

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Order Information for Assessories


Reference
MN
230V AC HDM1-63 HDM163MN230*
400V AC
HDM163MN400*
HDM1-100 HDM1100MN230*
HDM1100MN400*
HDM1-225 HDM1225MN230*
HDM1225MN400*
HDM1-400 HDM1400MN230*
HDM1400MN400*
HDM1-630 HDM1630MN230*
HDM1630MN400*
HDM1-800 HDM1800MN230*
HDM1800MN400*
HDM1-1250 HDM11250MN230*
HDM11250MN400*
Voltage (V) Type

Low-voltage Distribution

MX
HDM163MX230*
HDM163MX400*
HDM1100MX230*
HDM1100MX400*
HDM1225MX230*
HDM1225MX400*
HDM1400MX230*
HDM1400MX400*
HDM1630MX230*
HDM1630MX400*
HDM1800MX230*
HDM1800MX400*
HDM11250MX230*
HDM11250MX400*

OF
HDM163OF*

SD
HDM163SD*

TR(Round Handle)
HDM163TR

HDM1100OF* HDM1100SD* HDM1100TR

HDM1100TS

HDM1225OF* HDM1225SD* HDM1225TR

HDM1225TS

HDM1400OF* HDM1400SD* HDM1400TR

HDM1400TS

HDM1630OF* HDM1630SD* HDM1630TR

HDM1630TS

HDM1800OF* HDM1800SD* HDM1800TR

HDM1800TS

HDM11250OF*

Note 1: MN and MX could be sold with HDM1 product and installed by manufactory
2: *means the connecting type;
Blank: terminal connection;
D5: 500mm wire connection

9
8
10
7
11
1

12

5
4
13

Connection

Shunt release contacto

11

Alarm contactor

Phase partition

Undervoltage release contactor

12

Auxiliary contactor

Motor mechanism

Plug-type front connection

Round handle mechanism

Plug-type rear connection

Quadrate handle mechanism

10

Stationary type rear connection

105

TS(Square Handle)
HDM163TS

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Technical Data
Main technical parameters are shown in the table below
HDM1

MCCB
IEC 60947-2

Certicate

KEMA,SEMKO,CE

Rated frequency
Hz

50/60

Type

HDM1-63

HDM1-100

HDM1-225

HDM1-400

HDM1-630

HDM1-800

HDM1-1250

Rated insulation
voltage Ui V

690

800

800

800

800

800

800

Rated impulse
withstand voltage
Uimp KV

Rated operational
voltage Ue V

400

400

400

400

400

400

400

Breaking capacity

Poles

25

50

50

35

50

50

50 35

50

50

50

50

70

70

50

70

70

50

70

70

85

18

30

30

26

30

30

30 26

30

30

30

30

40

40

30

40

40

30

40

40

45

Rated Ultimate
short-circuit
breaking capacity
Icu kA
Rated service
short-circuit
breaking capacity
Ics kA

Low-voltage Distribution

Stardand

Mechanical
durabilities

8500

8500

7000

4000

4000

2500

2500

Electrical
durabilities

1500

1500

1000

1000

1000

500

500

Rated current

10/16/20/
25/40/50/63

16/20/25/
40/50/63/80/100

100/125/160/
180/200/225

200/225/250/
400/500/630
315/350/400

400/500/
630/700/800

700/800/
1000/1250

Working Conditions
Protection Level: IP20
Pollution Level: III
Correct Range of Working Environment: average temperature less than+35C within 24 hours
for - 5C ~ + 40C (please contact the manufacturer when over the range)
Altitude of installation shall be less than 2000 m, and the capacityreduction is adopted for being
used at 2000+ m.
The relative temperature of the atmosphere is not more than 50% when the highest temperature
is + 40C, and the relative temperature is higher under lower temperature (e.g. 90% at +20C),
and the condensation formed on the surface of the products for temperature change shall be
considered.
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip
against overcurrent
The circuit breaker can be fixed type or plug-in type
For 4-pole circuit breakers:
N-pole without overcurrent release, it switches on and off with other poles ( N-pole lead-make,
lag-break)
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the accessories part

106

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Accessories
The accessories are fixed into the circuit breaker.
Remote tripping:
MX or MN releases are used to trip the circuit breaker.
This release trips the circuit breaker when the control voltage drops below the tripping threshold:
Tripping threshold between 35% to 70% of the rated voltage
Circuit-breaker closing is possible only if the voltage exceeds 85% of the rated
voltage.
Circuit-breaker tripping by an MN release meets the requirements of standard
IEC 60947-2.
Low-voltage Distribution

power source input

MN (Undervoltage Release)
Technical data
Rated operating voltage Ue(V)
Drop-out voltage(V)
Pick-up voltage(V)

230V, 400V AC
(0.35~0.7) Ue
(0.85~1.1) Ue

MX shunt release:
The MX release trips the circuit breaker when the control voltage rises above
0.7 x Un.
Control signals can be of the impulse type (u 20 ms) or maintained.

MX (Shunt Release)
Technical data
power source input

Rated control voltage US(V)


Operating voltage(V)

230V, 400V AC
(0.7~1.1) US

Indication contacts:
These common-point changeover contacts can be used to remotely indicate circuit-breaker status
information for indications, electrical locking, relays, etc.
They comply with international standard IEC 60947-5.
Functions:
OF (ON/OFF): indicates the position of the circuit-breaker contacts.
SD (trip indication): indicates that the circuit-breaker has tripped due to: overload
short-circuit
operation of a voltage release
operation of thepush-to-trip
button Returns to de-energised state when the circuit breaker is reset.

OF (Auxiliary Contactor)

Trip position

Auxiliary Contact wiring diagram

Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC (Change over)
2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Contactor)
Technical data
Rated thermal current Ith 3A
Rated operating current
Alarm Switch wiring diagram

1NO+1NC

107

0.26A (400V AC)


0.4A (400V AC)

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
Type

Poles Overall Dimensions

Install dimensions

L1

H1

H2

135

21

76

89

74

21

25

117

3.5

HDM1-63M

135

21

76

99

82

28

25

117

3.5

HDM1-63M

135

21

103

99

82

28

25

117

3.5

HDM1-100M

150

51

65

103

87

24

--

129

4.5

HDM1-100L

150

51

92

87

68

25

30

129

4.5

HDM1-100M

150

51

92

103

87

24

30

129

4.5

HDM1-100M

150

51

122

103

87

24

30

129

4.5

HDM1-225M

165

64

75

124

104

24

--

126

5.5

HDM1-225L

165

64

107

108

87

24

35

126

5.5

HDM1-225M

165

64

107

124

104

24

35

126

5.5

HDM1-225M

165

64

142

124

104

24

35

126

5.5

HDM1-400L,M 3

257

105 140

146

100

36

44

215

6.5

257

105 184

146

100

36

44

215

6.5

HDM1-630L,M 3

270

118

182

160

108

41

58

200

270

118

240

160

108

41

58

200

HDM1-800L,M 3

280

102 210

146

103

34

70

243

HDM1-800M

280

102 280

146

103

34

70

243

HDM1-1250M

406

104 210

190

140.5

58

70

375

10

HDM1-400M
HDM1-630M

Low-voltage Distribution

HDM1-63L

Unit:mm

2P

3P

4P

Overall and cut-out diagram of round handle

hinge

108

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Overall and cut-out diagram of square handle

hinge

Centrally revolvable type


Unit:mm

Low-voltage Distribution

Dimension for handle mechanism(centrally revolvable type)


Frame
HDM1-63
HDM1-100
HDM1-225
HDM1-400
HDM1-630
HDM1-800

A
100
103.5
144
215
200
242

B
25
30
35
44
58
70

H
51
52
56
88
99
88

Remark:the shortest distance of G connecting rod is 50mm,and ex-factory standard configuration


is 150mm,please contact the factory,if the special customization is required.

Eccentrically rotating
Unit:mm

Dimension for handle mechanism(eccentrically revolvable type)


Frame
HDM1-100
HDM1-225
HDM1-400
HDM1-630
HDM1-800
109

A
35
35
65
60
48

B
11.5
31
15
15
15

H
46
48
61
61
66

HDM1 Molded Case Circuit Breaker

Standard: IEC 60947-2

Installation Location of Accessories


Installation Method for Tripping Release and Accessories Code

Alarm Switch

Lead Direction
Installation
at Left Side

Auxiliary Contact

Shunt Release

Under-voltage
Release

Installation
at Right Side

Handle
Low-voltage Distribution

Name of Accessory

Product Type
HDM1-63 HDM1-100
HDM1-225

HDM1-400

HDM1-630

HDM1-800

HDM1-1250

Alarm Switch
Shunt Release

Auxiliary Contact

Undervoltage Release
Auxiliary Contact
Shunt Release
Shunt Release
Undervoltage Release
Two Group Auxiliary Contact
Auxiliary Contact
Undervoltage Release
Shunt Release
Alarm Switch
Auxiliary Contact
Alarm Switch
Undervoltage Release
Alarm Switch
Shunt Release
Auxiliary Contact
Alarm Switch
Two Group Auxiliary Contact
Alarm Swtich
Auxiliary Contact
Undervoltage Release
Alarm Switch

110

HDM1 Molded Case Circuit Breaker


Standard: IEC 60947-2

Characteristic Curve of Circuit Breaker

max
min

min

min

Low-voltage Distribution

Instantaneous current

Delay trip

Instantaneous current

Delay trip

Instantaneous trip

For power distribution


HDM1-63 Time/current characteristic curve

Delay trip

Instantaneous trip

For power distribution


HDM1-100 Time/current characteristic curve

max

max

min

min

Delay trip
Delay trip

Instantaneous trip
Instantaneous trip

For power distribution


HDM1-400 Time/current characteristic curve

111

xma

max

Delay trip
Delay trip

Instantaneous trip
Instantaneous trip

For power distribution


HDM1-630 Time/current characteristic curve

Delay trip

Instantaneous trip
Instantaneous trip

For power distribution


HDM1-225 Time/current characteristic curve

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Function

Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and
long time delay trip against overcurrent
The residual operating current value can be fixed or adjustable
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the position indication contact,
for detail see the accessories part

Low-voltage Distribution

Coding System
Country code

Product name

Frame current

Breaking capacity

Current

Pole

HD

M1LE

100

16

100:100A
225:225A
400:400A

L: L type
M: M type

16: 16A

400: 400A

3:3 pole
4:4 pole

Usage

Residual current

N Pole

Blank for
S:30mA
distribution Y:100mA
protection

T:300mA
F:500mA
KY:30/100/500mA
KT:100/300/500mA

For HDM1LE
4pole:
A=A type
(Direct connect)
B=B type
(Direct connect,
lead-make, lag
break)

112

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Order Information
Type
HDM1LE-100 3P

Low-voltage Distribution

4P A

4P B

HDM1LE-225 3P

4P A

4P B

Note:* express residual current.

113

Rated
current In A
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
100
125
140
160
180
200
225
100
125
140
160
180
200
225
100
125
140
160
180
200
225

Reference
Type M
HDM1LE100M163
HDM1LE100M203
HDM1LE100M253
HDM1LE100M323
HDM1LE100M403
HDM1LE100M503
HDM1LE100M633
HDM1LE100M803
HDM1LE100M1003
HDM1LE100M164A
HDM1LE100M204A
HDM1LE100M254A
HDM1LE100M324A
HDM1LE100M404A
HDM1LE100M504A
HDM1LE100M634A
HDM1LE100M804A
HDM1LE100M1004A
HDM1LE100M164B
HDM1LE100M204B
HDM1LE100M254B
HDM1LE100M324B
HDM1LE100M404B
HDM1LE100M504B
HDM1LE100M634B
HDM1LE100M804B
HDM1LE100M1004B
HDM1LE225M1003
HDM1LE225M1253
HDM1LE225M1403
HDM1LE225M1603
HDM1LE225M1803
HDM1LE225M2003
HDM1LE225M2253
HDM1LE225M1004A
HDM1LE225M1254A
HDM1LE225M1404A
HDM1LE225M1604A
HDM1LE225M1804A
HDM1LE225M2004A
HDM1LE225M2254A
HDM1LE225M1004B
HDM1LE225M1254B
HDM1LE225M1404B
HDM1LE225M1604B
HDM1LE225M1804B
HDM1LE225M2004B
HDM1LE225M2254B

Type L
HDM1LE100L163
HDM1LE100L203
HDM1LE100L253
HDM1LE100L323
HDM1LE100L403
HDM1LE100L503
HDM1LE100L633
HDM1LE100L803
HDM1LE100L1003
HDM1LE100L164A
HDM1LE100L204A
HDM1LE100L254A
HDM1LE100L324A
HDM1LE100L404A
HDM1LE100L504A
HDM1LE100L634A
HDM1LE100L804A
HDM1LE100L1004A
HDM1LE100L164B
HDM1LE100L204B
HDM1LE100L254B
HDM1LE100L324B
HDM1LE100L404B
HDM1LE100L504B
HDM1LE100L634B
HDM1LE100L804B
HDM1LE100L1004B
HDM1LE225L1003
HDM1LE225L1253
HDM1LE225L1403
HDM1LE225L1603
HDM1LE225L1803
HDM1LE225L2003
HDM1LE225L2253
HDM1LE225L1004A
HDM1LE225L1254A
HDM1LE225L1404A
HDM1LE225L1604A
HDM1LE225L1804A
HDM1LE225L2004A
HDM1LE225L2254A
HDM1LE225L1004B
HDM1LE225L1254B
HDM1LE225L1404B
HDM1LE225L1604B
HDM1LE225L1804B
HDM1LE225L2004B
HDM1LE225L2254B

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Order Information

HDM1LE-400

Reference
Type M

3P

200
250
315
350
400

HDM1LE400M2003
HDM1LE400M2503
HDM1LE400M3153
HDM1LE400M3503
HDM1LE400M4003

4P A

200

HDM1LE400M2004A

225

HDM1LE400M2254A

250

HDM1LE400M2504A

315

HDM1LE400M3154A

350

HDM1LE400M3504A

400

HDM1LE400M4004A

200

HDM1LE400M2004B

225

HDM1LE400M2254B

250

HDM1LE400M2504B

315

HDM1LE400M3154B

350

HDM1LE400M3504B

400

HDM1LE400M4004B

4P B

Low-voltage Distribution

Rated
current In A

Type

Note:* express residual current.

Order Information for Accessories


Voltage
(V)
230V AC
400V AC

Type

Reference
MN

H
CDM1LE-100 CDM1LE100MN230
H
H
CDM1LE100MN400
H
H
CDM1LE-225 CDM1LE225MN230
CDM1LE225MN400
H
CDM1LE400MN230
H
H
CDM1LE-400

X*

OF

SD

TS(Square Handle) TR(Round Handle)

*H
CDM1LE100MX230 *H
CDM1LE100TS
CDM1LE100OF * H
CDM1LE100SD* H

H
CDM1LE100TR

*H
CDM1LE100MX400 *
*H
CDM1LE225MX230 *H
CDM1LE225TS
CDM1LE225OF * H
CDM1LE225SD* H

H
CDM1LE225TR

*H
CDM1LE225MX400 *
*H
CDM1LE400MX230 *H
CDM1LE400TS
CDM1LE400OF * H
CDM1LE400SD* H

H
CDM1LE400TR

*H
CDM1LE400MX400 *
CDM1LE400MN400
H

Note 1: MN and MX could be sold with HDM1LE product and installed by manufactory
2: *means the connecting type;
Blank: terminal connection;
D5: 500mm wire connection

114

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Technical Data
Type

HDM1LE-100

HDM1LE-225

HDM1LE-400

Frame size rated current A

100

225

400

Rated current In A

16 20 25 32 40

100 125 140 160

200 250 315

50 63 80 100

180 200 225

350 400

Rated frequency Hz

50/60

Rated insulation voltage Ui V

800

Rated operational voltage Ue V

400

Rated impulse withstand voltage Uimp V

8000

Number of poles

3P, 4P

Low-voltage Distribution

Icu kA

Type M

50

50

50

(400V)

Type L

30

30

Ics kA

Type M

35

35

30

(400V)

Type L

22

22

Rated residual Without delay

30/100/500

30/100/500

100/300/500

operating current

100/300/500

100/300/500

In (mA)

100/300/500

100/300/500

100/300/500

1/2 In

1/2 In

1/2 In

Electrical

1500

1000

1000

Mechanical

8500

7000

4000

Total

10000

8000

5000

With delay

Rated residual non-operating


current

In(mA)

Durability

Maximum break time for residual operating current protection


Number of poles

In

2 In

5 In

10 In

Max. break

Without delay

0.2

0.1

0.04

0.04

time S

With delay

0.5/1.15/2.15 0.35/1/2

0.25/0.9/1.9 0.25/0.9/1.9

Table for 4 pole HDM1LE (Neutral line)


Code

Note

N(direct connect)

N(direct connect N pole lead-make, lag-break)

Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip
against over current
The residual operating current value can xed or adjusted
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functionssuch as
undervoltage releaseshunt releaseONOFF position indication contactand tripped
position indication contactfor detail see the accessories part

115

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Handle mechanism

Unit:mm

Square Handle

Low-voltage Distribution

Centrally revolvable type

Dimension for handle mechanism


HDM1LE-100
Frame
Dimension

49

HDM1LE-225

HDM1LE-400

55

74

Accessories
The accessories are fixed into the circuit breaker.
Remote tripping:
MX or MN releases are used to trip the circuit breaker.
This release trips the circuit breaker when the control voltage drops below the trip
ping threshold:
tripping threshold between 0.35 and 0.7 times the rated voltage
circuit-breaker closing is possible only if the voltage exceeds 0.85 times the rated voltage.
Circuit-breaker tripping by an MN release meets the requirements of standard IEC 60947-2.

MN (Undervoltage Release)
Technical data

Power source input

Rated operating voltage Ue(V)


Drop-out voltage(V)
Pick-up voltage(V)

230V, 400V AC
(0.35~0.7) Ue
(0.85~1.1) Ue

116

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

MX shunt release:
The MX release trips the circuit breaker when the control voltage rises above 0.7 x Un.
Control signals can be of the impulse type (u 20 ms) or maintained.

MX (Shunt Release)
Technical data
Rated control voltage Us(V)
Operating voltage(V)

Low-voltage Distribution

Power source input

230V, 400V AC
(0.7~1.1) Us

Indication contacts:
These common-point changeover contacts can be used to remotely indicate circuit-breaker
status information for indications, electrical locking, relays, etc.
They comply with international standard IEC 60947-5.
Functions:
OF (ON/OFF): indicates the position of the circuit-breaker contacts.
SD (trip indication): indicates that the circuit-breaker has tripped due to: overload shortcircuit operation of a voltage release operation of thepush-to-trip button Returns to
deenergised state when the circuit breaker is reset.

OF (Auxiliary Contactor)

Trip position

Auxiliary Contact wiring diagram

Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC (Change over)
2NO+2NC (Change over)

0.4A (400V AC)

SD (Alarm Contactor)

Arm Switch wiring diagram

Technical data
Rated thermal current Ith 3A
Rated operating current
1NO+1NC

117

0.26A (400V AC)


0.4A (400V AC)

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions

Unit:mm

Low-voltage Distribution

Key to Overall Dimensions


Type

Poles Overall size


L1
HDM1LE-100L 3
92max
4
122max
HDM1LE-100M 3
92max
4
122max
HDM1LE-225L 3
107max
4
142max
HDM1LE-225M 3
107max
4
142max
HDM1LE-400L,M 3
150max
4
198max

L2
150max
150max
150max
150max
165max
165max
165max
165max
257max
257max

L3
94max
94max
110max
110max
94max
94max
110max
110max
150max
150max

L4
75max
75max
92max
92max
72max
72max
90max
90max
107max
107max

Installation size
a b
d
30 129 44.5
60 129 64.5
30 129 44.5
60 129 64.5
35 126 44.5
70 126 64.5
35 126 44.5
70 126 64.5
48 194 44.5
95 194 66.5

118

HDM1LE Earth-Leakage Circuit Breaker


Standard: IEC 60947-2

HDM1L-225 Time/Current characteristic curve Power distribution

max
min

Low-voltage Distribution

Instantaneous
Current Range

Delay Trip

Instantaneous
Trip

HDM1L-400 Time/Current characteristic curve Power distribution

max
min

Instantaneous
Current Range

Delay Trip
Delay Trip

119

Instantaneous
Trip
Instantaneous
Trip

I n

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Main Characteristics
Frame(A):1600N, 4000H1, 4000H2, 6300L
In (A):630 ~ 6300
Ue (V):400/415, 690
Poles: 3P & 4P
Type: fixed type & draw-out type
Certificates: CE KEMA
Standards:IEC 60947-2

Intelligent Control Units


iTR336
Basic function: L, S, I & G protection
Low-voltage Distribution

iTR336E
Basic protection function
Basic measurement function
Assistant function
iTR336H
Basic & advanced protection function
Multiple measurement function
Assistant function
Specific function
Communication function
iTR336H-L
Basic & advanced protection function
Multiple measurement function
Assistant function
Specific function
Communication function
Suitable for high and low temperature

Wiring Situations
Rear connection(horizontal & vertical)
Front connection
Mixed connection
Optional accessories

1 Spreaders
2 Vertical connection adapters
3 Cable lug adapters

Accessories
Remote control: shunt release, closing release, opening release, electric motor
Indication contacts: Auxiliary contacts, ready to close contact, 3-position
indication contacts, fault-trip indication contact, remote reset contact
Locks: chassis padlock, opening keylock, door interlock, 3-position interlock.
Mechanical interlock: lever interlocks, cable interlocks
Operation and protection: door frame, interphase barriers, safety shutters
Accessories of the control unit: N-phase external CT, ground return CT,earth-leakage CT
120

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Overall View
iTR336

iTR336E

IR

Isd

Ii

IR

Low-voltage Distribution

Ig

Isd

Ii

Ig

Basic Type

Standard Type

Protection:

Protection:

Long time + short time + instantaneous + earth fault

Long time + short time + instantaneous + earth fault


LED lights indicate the status of 3 phases

iTR336H

iTR336H-L

IR

Isd

Ii

IR

Ig

Isd

Ii

Ig

Advanced Type

High-low Temperature Type

Protection:

Protection:

Long time + short time + instantaneous + earth fault

Long time + short time + instantaneous + earth fault

Multiple protection, measurement, maintenance,

Multiple protection, measurement, maintenance,

communication functions.

communication functions.
Available in extreme situations, between -40C and 80C

121

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Long time-L

Long time-L

Long time-L

Long time-L

Short time-S

Short time-S

Short time-S

Short time-S

Instantaneous-I

Instantaneous-I

Instantaneous-I

Instantaneous-I

MCR

MCR

MCR

MCR

Ground fault-G

Ground fault-G

Ground fault-G

Ground fault-G

Under-voltage/alarm

Under-voltage/alarm

Over-voltage/alarm

Over-voltage/alarm

3-phase imbalance/alarm

3-phase imbalance/alarm

Phase sequence/alarm

Phase sequence/alarm

Under-frequency/alarm

Under-frequency/alarm

Over-frequency/alarm

Over-frequency/alarm

Low-voltage Distribution

Protection

Inverse power protection/alarm Inverse power protection/alarm


Voltage harmonic alarm(THDu) Voltage harmonic alarm(THDu)
Measurement

Auxiliary fuction Test function

Current harmonic alarm(THDi)

Current harmonic alarm(THDi)

Current

Current

Current

Voltage

Voltage

Voltage

Power

Power

Power

Frequency

Frequency

Frequency

Energy

Energy

Energy

Harmonic

Harmonic

Pre-Alarm

Pre-Alarm

Pre-Alarm

Self-diagnose

Self-diagnose

Self-diagnose

Fault history record

Fault history record

Fault history record

Test function

Test function

Test function

Load monitor

Load monitor

ZSI

ZSI
High to low temperature

Communication

Modbus

Modbus

122

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Overall View
Top fix
LED indicator light
Data Sheet
Control panel
Bottom
Terminal connector
CT connector
Magnetic flow/micro switch

Low-voltage Distribution

Direction
Alarm LED
Long-time LED
Short/instantaneous LED
Leakage LED
Advanced protect LED
Communication
Reset

Navigator
System setting
Confirm
Protection interface/return
Measurement interface/return
Move down
Move up

Control Panel
Long time-current setting
Long time-time setting
Short time-current setting Isd
Short time-time setting tsd
Ground fault-current setting Ig
Ground fault-time setting tg
Padlock
Test,instantaneous
Instantaneous current setting
Power
Test port

123

Alarm

IR

Isd/Ii

Ig/In

AP

Com

Reset

HDW9 Air Circuit Breaker


Standard: IEC 60947-2
Alarm

IR

Isd/Ii

Ig/In

AP

Com

Reset

Protect Characteristics

Alarm

IR

Isd/Ii

Ig/In

The protect characteristics of intelligent control unit divide to inverse time delayed.
protection and fixed time delayded protection.The intelligent control unit protect as fixed
time delayded protection when the failure current is over inverse time delayed protection
AP settings.
Com
Reset
Inverse time delayed protection curve meet the curve of I t.

Over-load Protect Characteristics


Tripping Characteristics
<1.05 IR: >2h non-tripping;
>1.2 IR: <1h tripping;
1.2 IR: delay tripping;
Low-voltage Distribution

IR setting range: 0.4In0.5In0.6In0.7In0.8In0.9In0.95In0.98In1.0In


Inverse Time Protection Tripping Characteristics
Current
1.5 IR
2 IR
6 IR

Tripping time
16s
32s
9s
18s
1s
2s

64s
36s
4s

128s
72s
8s

I2 t: t=(6/N)2 *tR
192s
108s
12s

256s
144s
16s

320s
180s
20s

384s
216s
24s

480s
270s
30s

N---Failure current I/IR


Alarm

IR

Isd/Ii

Ig/In

AP

Com

Reset

t---Failure tripping delayed time


tR--- Long delayed time setting
Tripping time error 10%

Short-circuit Short Delay Protect Characteristics


Tripping Characteristics

<0.9 Isd: >2h non-tripping;


>1.1 Isd: <1h tripping;
1.1 Isd: delay tripping;

Isd setting range: 1.5 IR 2 IR 3 IR 4 IR5 IR6 IR8 IR10 IR+OFF


Current

Tripping Time

Isd<I 8IR

Inverse time

I 1.1Isd

Tripping time of
xed is the
minimum time.

lsd---Short time delay current

I2t=(8IR)2 tsd
Setting time
s
Setting time
s
Min. s
Max. s

0.10.20.30.4
0.1

0.2

0.3

0.4

0.08

0.14

0.23

0.35

0.14

0.2

0.32

0.5

l---Failure current
lR---Long delay current
t---Tripping time
tsd--- Short delay inverse time
Tripping time error 20%

Short-circuit Instantaneous Protect Characteristics

Tripping Characteristics
<0.85li: non-tripping;
>1.15li: tripping;

Instantaneous current:2In3In4In6In8In10In12In15In+OFF
Tripping time error 50ms

124

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Ground Return Protect Characteristics

Tripping Characteristics

<0.9 Ig: non-tripping;


>1.1 Ig: tripping;
1.1 Ig: delay tripping;

Current
In< 1250

A
0.2In

B
0.3In

C
D
E
F
G
H
0.4In 0.5In 0.6In 0.8In 0.9In In

In 1250

500A

600A

700A 800A 900A 1000A 1100A 1200A

tg(s)

Inverse time Tripping Characteristics

OFF

Ig
Low-voltage Distribution

Tripping
time of
xed is the
minimum
time.

Setting time s

0.10.20.30.4

Setting time s

0.1

0.2

0.3

0.4

Min. s

0.08

0.14

0.23

0.35

Max.s

0.14

0.2

0.32

0.5

lg: ground protection current. In 1250, Ig=1200A.In<1250, Ig=In.


I: Breakdown current
T: Tripping delayed time
tg: Grounding inverse time
Inverse tripping time error 20%

Factory Default Settings


Curve
It

Long delay

Short delay

IR

tR

Isd

1In

30s

6In

Inst.

Ground fault

ts

Ii

Ig

tg

0.2s

10In

0.4s

Memory
20min

Details refers to "HDW9 Intelligent Control Unit User Manual-1600N, 4000H1&H2"

125

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

RESET

RESET
iTR336

RESET

iTR336E

In=

In=

iTR336H

In=

iTR336 Protect Characteristics


Over-load Protect Characteristics

MCU

Tripping current IR
A

0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0In+OFF

reset
warm/alarm

Delayed time setting tR


kA
s

test

L1

L3 MAX select

Tripping current of xed time Isd

Delayed time of xed time tS

tR
tsd
tg
Ig

reset

3, 4, 5, 6, 7, 8, 10In+OFF

clear

trip

test

bus

Short-circuit Short Delay Protect Characteristics

L2
warn

check

30s, 60s, 120s, 240s

healthy

IR

Isd

0.2s, 0.4s

Short-circuit Instantaneous Protect Characteristics


Ii

(78910111214) In+OFF

check

trip nontrip

Low-voltage Distribution

Tripping current Ii

set

memory

test
test

Ground Return Protect Characteristics


adjust

Tripping current Ig

0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8In+OFF

Delayed time tg

0.1s0.2s0.3s0.4s

iTR336E Protect Characteristics


Over-load Protect Characteristics
(0.4 1.0)In+OFF

Tripping current IR
RESET

RESET
iTR336

In=

iTR336E

F a i l u r e

RESET
In=

iTR336H

Delayed
time setting tR
In=

Current

MCU

A
kA
s

test

L1

L2

reset
warm/alarm
healthy
bus

60

120

240

480

1.5xIR

15

30

60

120

240

480

2xIR

8.4

16.9

33.8

67.5

135

270

7.2xIR

0.65

1.3

2.6

5.2

10.4 20.8

t=Delayed failure tripping time

tR

tR=Delayed tripping time

tsd
tg
Ig

reset

30

N=Failure Current I/IR

clear

test

15

warn

check

tR

t=(1.5/N) xtR

L3 MAX select

trip

Delay Time

IR

Isd

Ii

set
trip nontrip
test
test

check
memory
adjust

Short-circuit Short Delay Protect Characteristics

Tripping current of fixed time


0.4 15In+OFF Step: below 10kA: 2A, above 10kA: 10A
Isd
Delayed time of xed time tS

IT

Failure Current Delay Time


2

I T: OFF
2

I T:ON
I>8IR
2
I T: ON
I 8IR

ts(s)
0.1
0.2
Min.delay(ms) 60
160
Max.delay(ms) 140
240
Min.delay(ms) 60
160
Max.delay(ms) 140
240
2 2
Inverse time
t=(8IR) /I ts

0.3
255
345
255
345

0.4
340
460
340
460

Short-circuit Instantaneous Protect Characteristics


Tripping current Ii
2.0In 100kA+OFF
Ground Return Protect Characteristics
Tripping current Ig
(0.2 1.0)In+OFF
Delayed time tg

0.1s0.2s0.3s0.4sOFF

126

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

RESET
iTR336E

RESET
In=

iTR336H

In=

iTR336H Protect Characteristics


Over-load Protect Characteristics

A
kA
s

test

L1

L2

reset
warm/alarm
healthy

Tripping current IR

OFF+0.4 1.0In

Tripping curves

SI: Standard inverse time

Protection type

VI: Rapid Inverse Time

bus

EI(G): Express inverse time (distribution)

L3 MAX select

EI(M): Express inverse time (electromotor)

warn

clear

trip
T

HVHigh voltage fuse compatibility

tR
tsd
tg
Ig

IR

Isd

Ii

set

check

Low-voltage Distribution

trip nontrip
test
test

memory

I2t: Universal inverse time protection

Delayed time setting

C01 C16

Short-circuit Short Delay Protect Characteristics


adjust

Tripping current of inverse time Is

OFF+(0.4 15)In

Tripping current of xed time Isd

OFF+(0.4 15)In

Delayed time of xed time tsd

0.1 0.4s

Short-circuit Instantaneous Protect Characteristics


Tripping current Ii

2.0In 100kA+OFF

Ground Return Protect Characteristics


Tripping current Ig

OFF+(0.2 1.0)In

Shearing coefcient of inverse time Cr

(1.5 6)+OFF

Delayed time tg

0.1 1s

Factory Default Settings


Controller

Long
delay

Curve
IR

tR

1In

60s

iTR336
iTR336E
iTR336H

127

I 2t

Short delay
Isd

Isd2 ts

4In

6In

8In

Inst. Ground fault Monitering Ic1, Ic2 Memory


Ii

Ig

tg

0.2s 10In 0.8In 0.4s

1In

20min

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Remote Operation
Shunt Release MX
After the circuit breaker is closed, the shunt release can open the circuit breaker
instantaneously under required power voltage. The operation can be done remotely.
Rated control power voltage: AC220V/AC230V, AC380V/AC400V, DC220V
Operating voltage: (0.7-1.1) Us
Break time: 5010ms (1600N,4000H1&H2)
<30ms (6300L)
Closing Release XF

Low-voltage Distribution

After the circuit breaker completes energy storage, the closing release can close the circuit
breaker under required power voltage. The operation can be done remotely.
Rated control power voltage: AC220V/AC230V, AC380V/AC400V, DC220V
Operating voltage: (0.85-1.1) Us
Closing time: 5510ms(1600N)
7010ms(4000H1&H2,>3200A,8010ms)
Under-voltage Release MN
The under-voltage release can be divided s to under-voltage release and under-voltage
delayed release.
After the circuit breaker is closed and the voltage will drop to 70% to 35% of rated voltage,
the circuit breaker can be opened, and the breaker can only be closed again when the
power voltage of the under-voltage release returns to 85% of rated voltage.
Rated control power voltage: AC220V/AC230V, AC380V/AC400V
Operating voltage: (0.35-0.7) Ue
Reliable closing voltage: (0.85-1.1) Ue
Voltage that can not be closed: 0.35Ue
Delay time: 0.5s, 0.9s, 1.5s, 3s(1600N,4000H1&H2),1s,3s,5s(6300L)

Under-voltage Delayed Release MNR


The under-voltage delay release can open the circuit breaker after 0.5s, 0.9s, 1.5s, 3s
(1600N,4000H1&H2),1s,3s,5s(6300L)
Electric Motor MCH
The electric motor can store energy for the circuit breaker automatically when it is power
on and the circuit breaker is open. The electric motor can open or close the circuit breaker
with the shunt release, under-voltage release and closing voltage release. When there is no
power supply, the handle can store energy for the circuit breaker.
Rated control power voltage: AC220V/AC230V, AC380V/AC400V, DC220V
Operating voltage: (0.85-1.1) Us
Power consumption: 180W(1600N,4000H1&H2),150W(6300L)
Energy storage time: <5s
Utilization category: AC15, DC13

128

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Indication Contacts
Auxiliary Contacts OF
Default: 4NO and 4NC(12NO 12NC or 8NO 8NC are for option,5NO 5NC for 6300L) Auxiliary
Contacts can be used to indicate the status of the circuit breaker, e.g.
connecting the status indicator of the circuit breaker.
Rated thermal current Ith: AC380V/AC400V 0.75A, AC220V/AC230V 1.3A, DC220V 0.15A
Ready to Close Contact PF

Low-voltage Distribution

Ready to close contact is composed of a mechanical indicating contact and a transferring


contact. It can send closing signal and indicate:
- The circuit breaker is disconnected
- The energy is stored
- No continued opening command
AC12/DC12: AC380V/AC400V 3A, DC220V 0.15A
Connection (CE), Separation (CD), Test (CT) Position Indication Contacts
Connection (CE), Separation (CD), Test (CT) position indication contacts are installed on the
chassis for indicating the position of the circuit breaker.
Draw-out type only.
Fault-trip Indication Contact(Additional) SWT2
When there is electrical malfunction, the contact provides a set of malfunction signal outputs.
Remote Reset Contact Res
When there is electrical malfunction, after the circuit breaker is opening, the contact can
allow malfunction locking device of the circuit breaker to be remotely reset. This contact is not
compatible with additional SWT fault-trip indication contact.
Only for iTR336H, iTR336H-L

Keylocks and Interlocks


OFF Position Padlock
The padlock should be prepared by the client.
The rocker cannot be inserted after the padlock locked, when the circuit breaker is at
"separation" position.
OFF Position Keylock
The opening lock can lock the circuit at OFF position. The circuit breaker can only be closed
when the lock is opened with a key and the key is not pulled out. The opening lock can be
divided s into 3 types (the latter 2 types are used in distribution system with two wirings and one
contacting):
1 lock and 1 key
2 locks and 1 key
3 locks and 2 keys
Door Interlock
The interlock is installed at the side of draw-out type circuit breaker and linked with the door of
the distribution cabinet. When the circuit breaker is at connection or test position, it ensures that
the cabinet door cannot be opened. The cabinet door can be opened at separation position. It
can prevent the circuit breaker from slipping and causing damage.
3-position Interlock
For the draw-out type circuit breaker, the "connection", "test" and "separation" position of the
circuit breaker can be indicated by the indicator. The in-out button is locked at indicated by the
indicator. The in-out button is locked at The in-out button is locked at each position. Push to
unlock.

129

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Mechanical Interlock
Lever Interlock and Cable Interlock
Lever interlock is used for two circuit breakers installed vertically. Cable interlock is used
for 2 or 3 circuit breakers installed vertically or horizontally.
The interlocks is used in distribution system with two wirings and one contacting.
The interlocks build mechanical links between 2 or 3 circuit breakers.
If one circuit breaker is closed, the linked circuit breaker will be opened.

Operation Protection
Door Frame
Low-voltage Distribution

The door frame is installed on the door of the distribution cabinet, and can increase
the protection degree to IP40.
Suitable for fix-type and draw-out type.
Interphase Barriers
The Interphase barriers are insulating plates installed in the middle of busbar to increase
creepage distance and insulating ability.
The Interphase barriers are installed between the front and rear connecting terminals.
Safety Shutters
The safety shutters is installed in draw-out type circuit breaker. When the circuit breaker is at
test or separation position, the safety shutters can protect contact cables prevent operators
from touching live parts.

Accessories of Control Unit


N-phase External Current Transformer
N-phase external current transformer is used to measure neutral phase current in 3P+N
grounding system and it is installed on the grounding busbar by the client.
Ground Return Current Transformer
Ground return current transformer is used to measure the neutral phase current under
grounding type of grounding current return. The current transformer can also provide
protection for up and down grounding defects of the circuit breaker.
The grounding current transformer is only suitable for iTR336H and iTR336H-L controller.
Earth-leakage Current Transformer
Earth-leakage current transformer is used for the grounding protection type of leakage
protection.
The Earth-leakage Current Transformer is suitable for iTR336H and iTR336H-L controller.
Power Supply Module
The power supply module can be used in AC220V/AC230V, AC380V/AC400V, DC220V
circuits and provide power supply for intelligent controller. And the output is DC24V.
The power supply module of HDW9-6300L is used in DC220V circuits and provides power
supply for intelligent controller. And signal convert module works with power supply module.
Signal Convert Module
Signal convert module is used for communication function, e.g. zone selective interlock
function. The iTR336H and iTR336H-L controller are equipped with it.

130

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Rear Connections
Vertical

Horizontal

Low-voltage Distribution

For 1600N, horizontal and vertical connection methods transforms by rotating the connection
terminal 90 degree.
For 4000H1&H2, horizontal and vertical connection terminals are different, please remark when order.
For 6300L, horizontal connection is the only methods.

Front Connections 630A~3200A

Spreaders (1600N only)


Horizontal Rear Connection with Spreadersl

Front Connection with Spreaders

131

Vertical Adapters

Cable-lug Adapters

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Optional Connection Solutions


Type

4000H1, 4000H2

1600N
Draw-out Type

Fixed Type

Rear

Rear

Front

Front

6300L

Draw-out Type

Fixed Type

Rear

Rear

Front

Draw-out
Front

Rear

Spreaders

Low-voltage Distribution

Vertical-connection Adapters

Cable-lug Adapters

Interphase Barriers

*1) Interphase barriers must be used over 500V.


*2) 4000A horizontal rear connection is not included.

132

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

HDW9 Coding System


Product
Name

Frame

Rated
current

Poles Installation method

MCH / XF / MX / Power supply module MN/MNR

Auxiliary contact Intelligent control unit

W9

40H2

32

DH

W9:HDW9

16N:1600N(Icu=50kA)

06:630A

3:3P

DH:Drawout Horizontal

N:AC230V

N:MN AC230V

F:4NO4NC

B:iTR336

40H1:4000H1(Icu=65kA)

08:800A

4:4P

E:8NO8NC

E:iTR336E

FH:Fixed Horizontal

V:AC400V

V:MN AC400V

40H2:4000H2(Icu=100kA) 10:1000A

DV:Drawout Vertical

D:DC220V

P:MNR AC230V T:12NO12NC

H:iTR336H

63L:6300L(Icu=120kA)

12:1250A

FV:Fixed Vertical

T:MNR AC400V V:5NO5NC

L:iTR336H-L

16:1600A

DF:Drawout Front-connection

5:None

20:2000A

FF:Fixed Front-connection

25:2500A

Remarks:

32:3200A

1.Front-connection type device is NOT available for HDW9 which rated current is 4000A.

40:4000A

2.Fixed type device is NOT available for HDW9-6300L.

Low-voltage Distribution

50:5000A

3.4P type device is NOT available for HDW9 which rated current is 6300A.

63:6300A

4.1600N offers 4NO4NC; 4000H offers 4NO4NC, 8NO8NC, 12NO12NC; 6300L offers 5NO5NC.
5.iTR336H-L is NOT available for 6300L.

Accessories References
Reference

Remarks

Intelligent Control Unit


HDW9TU0

iTR336

HDW9TUE

iTR336E

HDW9TUH

iTR336H

HDW9TUHL

iTR336H-L (1600N,4000H1&H2)

HDW9MX2A
HDW9MX4A
HDW9MX2D
HDW9MX2A63
HDW9MX4A63
HDW9MX2D63
HDW9XF2A

AC230V (1600N,4000H1&H2)
AC400V (1600N,4000H1&H2)
DC220V (1600N,4000H1&H2)
AC230V (6300L)
AC400V (6300L)
DC220V (6300L)
AC230V (1600N,4000H1&H2)

Remote Operation
Shunt Release MX

Closing Release XF

Under-voltage Release MN

Under-voltage delayed Release MNR


1

4 5

S
3 6

Electric motor MCH

133

0.5

1.5
3
MN
r de
UVR
dateu
Retardelay for
Time

MN
UVR
30 V
100/1C
AC/D

1012

HDW9XF4A

AC400V (1600N,4000H1&H2)

HDW9XF2D

DC220V (1600N,4000H1&H2)

HDW9XF2A63

AC230V (6300L)

HDW9XF4A63
HDW9XF2D63
HDW9MN2A

AC400V (6300L)
DC220V (6300L)
AC230V (1600N,4000H1&H2)

HDW9MN4A

AC400V (1600N,4000H1&H2)

HDW9MN2A63

AC230V (6300L)

HDW9MN4A63

AC400V (6300L)

HDW9MNR2A

AC230V (1600N,4000H1&H2)

HDW9MNR4A

AC400V (1600N,4000H1&H2)

HDW9MNR2A63

AC230V (6300L)

HDW9MNR4A63

AC400V (6300L)

HDW9MCH162A

AC230V (1600N)

HDW9MCH164A

AC400V (1600N)

HDW9MCH162D

DC220V (1600N)

HDW9MCH402A

AC230V (4000H1&H2)

HDW9MCH404A

AC400V (4000H1&H2)

HDW9MCH402D

DC220V (4000H1&H2)

HDW9MCH632A

AC230V (6300L)

HDW9MCH634A
HDW9MCH632D

AC400V (6300L)
DC230V (6300L)

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Operation Protection
Door Frame

Interphase Barriers

HDW916FCDP

1600N xed type

HDW916DCDP

1600N draw-out type

HDW940FCDP

4000H1&H2 xed type

HDW940DCDP

4000H1&H2 draw-out type

HDW963DCDP

6300L draw-out type

HDW916FEIP

1600N xed type

HDW916DEIP

1600N draw-out type

HDW940FEIP

4000H1&H2 xed type

HDW940DEIP
HDW963DEIP

4000H1&H2 draw-out type


6300L draw-out type

HDW9V3

1600N 3P vertical adapters

HDW9V4

1600N 4P vertical adapters

HDW9C3

1600N 3P cable-lug adapters

HDW9C4

1600N 4P cable-lug adapters

HDW9S3

1600N 3P spreaders

HDW9S4

1600N 4P spreaders

HDW9OF4416

4NO 4NC--1600N

HDW9OF4440

4NO 4NC--4000H1&H2

HDW9OF88

8NO 8NC--4000H1&H2

HDW9OF12

12NO 12NC--4000H1&H2

HDW9OF55

5NO 5NC--6300L

HDW916PF

1600N

HDW940PF

4000H1&H2

HDW916EDT

1600N

HDW940EDT

4000H1&H2

HDW916SWT2

1600N

HDW940SWT2

4000H1&H2

HDW916RES

1600N

HDW940RES

4000H1&H2

Low-voltage Distribution

Connection Accessories

Indication Contacts
Auxiliary Contacts OF

Ready to Close Contact PF

3-Position Indication Contacts(CE, CD, CT)

Fault-Trip Indication Contact(Additional) SWT2

Remote Reset Contact Res

134

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Accessories of the Control Unit


N-Phase External Current Transformer

HDW9N16

1600N

HDW9N40

4000H1&H2

HDW9N63

6300L

Low-voltage Distribution

Ground Return Current Transformer

HDW9G

Earth-Leakage Current Transformer

HDW9L

Power Supply Module

HDW92AP

AC230V

HDW94AP

AC400V

HDW92DP

DC220V

Signal Convert Module

HDW9TR

Keylock and Interlock


HDW916L1

Keylocks

HDW916L2
HDW916L3
HDW940L1
HDW940L2
HDW940L3
HDW963L1
HDW963L2
HDW963L3
HDW9DLL16

Door Interlocks
ER
LIN G
M ER

IN

1600N--1 lock 1 key


1600N--2 locks 1 key
1600N--3 locks 2 keys
4000H1&H2--1 lock 1 key
4000H1&H2--2 locks 1 key
4000H1&H2--3 locks 2 keys
6300L--1 lock 1 key
6300L--2 locks 1 key
6300L--3 locks 2 keys
1600N xed type--left

HDW9DLR16

1600N draw-out type--right

HDW9DLL40

4000H1&H2 xed type--left

HDW9DLR40

4000H1&H2 draw-out type--right

HDW9DLL63
HDW9DLR63

6300L draw-out type--left


6300L draw-out type--right

HDW916FLL2
HDW916DLL2
HDW940FLL2
HDW940FLL3
HDW940DLL2
HDW940DLL3
HDW963DLL2
HDW963DLL3
HDW916FGL2
HDW916DGL2
HDW940FGL2
HDW940DGL2
HDW963DGL2
HDW963DGL3

1600N xed type--2 devices


1600N draw-out type--2 devices
4000H1&H2 xed type--2 devices
4000H1&H2 xed type--3 devices
4000H1&H2 draw-out type--2 devices
4000H1&H2 draw-out type--3 devices
6300L draw-out type--2 devic
6300L draw-out type--3 devices
1600N xed type--2 devices
1600N draw-out type--2 devices
4000H1&H2 xed type--2 devices
4000H1&H2 draw-out type--2 devices
6300L draw-out type--2 devices
6300L draw-out type--3 devices

Mechanical Interlock
Cable Interlocks

Lever Interlocks

135

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

HDW9 Accessories Instruction

Low-voltage Distribution

Remote Operation

Indication Contacts

Locks

Mechanical Interlock

Protection

15 Mechanical interlock

16 Door frame

Controller
Accessories

1 Shunt release

6 Auxiliary contacts

11 OFF position padlock

2 Closing release

7 Ready to close contact

12 OFF position keylock

17 Interphase barriers 20 Ground return CT

3 Under-voltage

8 3-position indication

13 Door interlockOFF

18 Safety shutters

release
4 Under-voltage
delayed release
5 Electric motor

contacts(CE, CD, CT)


9 Faultt-trip indication
contact (SWT)
10 Remote reset contact

19 N-phase external CT

21 Earth-leakage CT

position keylock
14 3-position interlock

22 Power supply
module
23 Signal convert
module

136

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Configuration
1600N

4000H1

4000H2

6300L

iTR336

iTR336E

iTR336H

iTR336H-L

Shunt release

Closing release

Electric motor

Under-voltage release

Under-voltage delayed release

Door frame

Interphase barriers *1)

Horizontal rear connection


Horizontal rear connection with
spreaders
Vertical rear connection

Front connection *2)

Front connection with spreaders

Front connection with vertical-connection adapters

Main Body
Main body of circuit breaker
Components
Intelligent
control unit

Remote
operation
Low-voltage Distribution

Operation
protection
Wiring
methods

Indication
contacts

Control unit
accessories

Locks
Mechanical
interlock

Front connection with cable-lug


adapters
4NO 4NC
Auxiliary contacts

5NO 5NC

8NO 8NC

12NO 12NC

Ready to close contact


Fault-trip indication contact
SWT2 (additional)

3-position indication contacts *3)

Remote reset contact *4)*5)

N-phase external current transformer

Ground return current transformer *4)

Earth-leakage current transformer *4)

Power supply module

Signal convert module *4)

OFF position keylock

Door interlock

Cable interlock

Lever interlock

*1) Details refers to P132


*2) Front connection is not available for 4000H1&H2 4000A.
*3) Only for draw-out type
*4) Only for iTR336H, iTR336H-L
*5) Not compatible with additional fault-trip indication contact(SWT2)

137

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
105 (3P)
175 (4P)

105
188
94

210

178
136
105

X
123

11.5

39
150,5
F

125 (3P)
195 (4P)

13

125

13

Horizontal installation on board or railway

Vertical installation on back board or frame


Y

6 6.5

4 6.5
25

100

X
39

100

Min 18
Max 39

136.5

125 (3P)
195 (4P)

Safety clearances

A (*)

125

Rear panel holes dimensions

Door frame

154
77

125

125 (3P)
195 (4P)

A (*)

125

62,5

Min 194 (3P)


Max 264 (4P)

Min 194

62
44

40

130

108 (1)
133 (2)

194 (1)
244 (2)

216 (1)
266 (2)

100 (3P)
170 (4P)

62
106
100

97 (1)
122 (2)

F : Base point

Non-conductor Metals Electric conductor

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's
mask.
Removing the arc chutes needs 50mm safety clearance.
Removing terminal blocks needs 20mm safety clearance.

138

Low-voltage Distribution

15

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection
43.5

70

70

70

15
123
67.5

67.5
44

123

25

15

9.5 12.5
60

167.5
Low-voltage Distribution

12.5

F
2 11

Vertical rear connection


43.5

70

70

70
15
A

97

97

60
12.5
9.5

12.5

167.5
F

44

2 11

25

Front connection
12

A
70

150

326

70

70

Y
A

44
25

2 11
9.5

13

150

13
2 11
164
F

Remarks: Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.

139

25
44

9.5

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Front connection with spreaders
95

95

70

70

15

202

Y
434

95

95
70

95

70

70
12.5

15

179
F

Rear connection with spreaders


95
98

95

70

70

123
15

15

82.5

52.5

123

95

95
70

219.5

95

70

70

12.5

12.5

234.5
F

N
Middle spreader for 3P

Middle left or right spreader for 4P

77

77
38.5
25

Left or right spreader for 4P

13.5

15
5 11

25

13.5

30
82 52

38.5
25

13.5

30

30
82 52

15

15

5 11
52

82 52

15
5 11

5 11

25

25
52

77

38.5

13.5

30
82 52

Left or right spreader for 3P

77

38.5
25

25

25
52

52

Base point

Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
140

Low-voltage Distribution

12.5

202

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Front connection with vertical-connection adapters
116.5

70

70

70
15
A

21

221

472

89
= =

Low-voltage Distribution

25

15

21 (1)
101

221

21

12.5

3 11
15

21

20
A

190.5
253
F

Front connection with vertical-connection adapters and cable-lug adaptersand cable-lug adapters
15

221

70

70

70
15

50

271
21

221

N
572

Y
184

17

50

50

50

50

80
21

221
271

5 13

5 11
A

50

340.5
357.5
F

Remarks:Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.

141

15

15

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions

127.5 (3P)
197.5 (4P)

Min
210

160.5
188

94

46 (*)

199

123

49.8

60 mini

90 (3P)
160 (4P)

231
F

Low-voltage Distribution

90

Horizontal installation on board or railway

Vertical installation on back board or frame

4 6.5

6 6.5

150

X
25

24

50

25 100

100
216
231
F

90 (3P)
160 (4P)

Safety clearances

90

109 (3P)
179 (4P)

Door holes dimensions


B

B
C

Min 170 (3P)


Max 240 (4P)

109

Rear panel holes dimensions

Min 230

259 (1)
303 (2)

234
117

40
180
F

161 (1)
183 (2)

Non-conductor

A
B
C

0
10
0

Base point

Metals

0
10
0

Electric conductor

90
60
90

109 (1)
130.8 (2)

102.5 (3P)
172.5 (4P)

102.5

259 (1)
307 (2)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole
breaker's mask.

142

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection
70
49

70

70

15

67.5
228

X
N
Y
67.5
114

44
25

Low-voltage Distribution

15

267.5
F

9.5 12.5
60
12.5

2 11

Vertical rear connection


70

70

70
15

49

A
97

X
N
Y
97
60
12.5
9.5

12.5

267.5
F

44

2 11

25
A

Front connection
15

12.5

70

70

70

171

N
Y
336

X
44

140
9.5

25

37.9

2 11

9.5
26

235

12.5

83

131

52

26

2 11

25
37.9

A
143

9.5

100

44

9.5

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Front connection with spreaders
95

95

70

70

15

202

Y
434

95

95
70

95

70

70
12.5

15

179
F

Rear connection with spreaders

95
98

95

70

70

123
15

15

82.5

52.5

123

95

95
70

219.5

95

70

70

12.5

12.5

234.5
F

N
Middle spreader for 3P

Middle left or right spreader for 4P

77

77
38.5
25

13.5

25

15
5 11

77

38.5

13.5

25

13.5

30
82 52

38.5
25

13.5

30

30
82 52

15

15

5 11
52

82 52

15
5 11

5 11

25

25
52

Left or right spreader for 3P

77

38.5

30
82 52

Left or right spreader for 4P

25

25
52

52

Base point
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
144

Low-voltage Distribution

12.5

202

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Front connection with vertical-connection adapters
116.5

70

70

70
15
A

21

221

472

89
= =

Low-voltage Distribution

25

15

21 (1)
101

221

21

12.5

3 11
15

21

20
A

190.5
253
F

Front connection with vertical-connection adapters and cable-lug adaptersand cable-lug adapters
15

221

70

70

70
15

50

271
21

221

N
572

Y
184

17

50

50

50

50

80
21

221
271

5 13

5 11
A

50

340.5
357.5
F

Remarks:Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.
145

15

15

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
127.5 (3P)
197.5 (4P)

Min
210

160.5
188

94

46 (*)

199

Low-voltage Distribution

123
5

49.8

60 mini

90 (3P)
160 (4P)

231
F

90

Horizontal installation on board or railway

Vertical installation on back board or frame

4 6.5

6 6.5

150

X
25

24

50

25 100

100
216
231
F

90 (3P)
160 (4P)

Safety clearances

90

109 (3P)
179 (4P)

Door holes dimensions


B

B
C

Min 170 (3P)


Max 240 (4P)

109

Rear panel holes dimensions


Min 230

259 (1)
303 (2)

234
117

40
180
F

161 (1)
183 (2)

Non-conductor

A
B
C

0
10
0

Base point

Metals

0
10
0

Electric conductor

90
60
90

109 (1)
130.8 (2)

102.5 (3P)
172.5 (4P)

102.5

259 (1)
307 (2)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole
breaker's mask.

146

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection
70
49

70

70

15

67.5
228

X
N
Y
67.5
114

44
25

Low-voltage Distribution

15

267.5
F

9.5 12.5
60
12.5

2 11

Vertical rear connection


70

70

70
15

49

A
97

X
N
Y
97
60
12.5
9.5

12.5

267.5
F

44

2 11

25
A

Front connection
15

12.5

70

70

70

171

N
Y
336

X
44

140
9.5

25

37.9

2 11

9.5
26

235

12.5

83

131

52

26

2 11

25
37.9

A
147

9.5

100

44

9.5

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
Front connection with spreaders
95

95

70

70

238
223

Y
X
95

95

207
192

95

70

70

12.5

250

12.5

Rear connection with spreaders

95

95

70

70

116

123
15

15

82,5

Y
95

52,5

95
70

95

70

70

12.5

12.5

319.5
334.5
F

N
Middle left or right spreader for 4P

Middle spreader for 3P


77

77
38.5
25

Left or right spreader for 4P

13.5

15
5 11

25

13.5

30
82 52

38.5
25

13.5

30

30
82 52

15

15

5 11
52

82 52

15
5 11

5 11

25

25
52

77

38.5

13.5

30
82 52

Left or right spreader for 3P

77

38.5
25

25

25
52

52

Base point

Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
148

Low-voltage Distribution

70

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Front connection with vertical-connection adapters

70

71

70

70
15

21

A
171

Low-voltage Distribution

140
21

89
= =

25
71

12.5
15

21 (1)
101

21

3 11
15

193.5

20

Front connection with vertical-connection adapters and cable-lug adapters

15

70

70

70
A

15

50
71
292
21

171

Y
184

583

15

17

50

50

50

140
21

5 13

71

50
193.5
F

Base point

Remark: Screws: M10 Class8.8


Fasten torque: 50Nm with gasket

149

50

80

261

15

5 11

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions of Extend Current Transformers


N-phase Extend Current Transformer
38.4

83.4

63

Low-voltage Distribution

59.2

Earth-leakage Current Transformer

130

115
210
256

51
46

280
340
390

92

72

22

147

8
M6

250

Ground Return Current Transformer


19
19

4X7

93

150

190

100

146
185

M6X20

45
50
70
90

50
100

150

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
189 (3P)
304 (4P)

189
308
154

Y
191
150
260

X
161

Low-voltage Distribution

11

14

57

233

11

Horizontal installation on board or railway

200 (3P)
315 (4P)

200

11

Vertical installation on back board or frame


Y

9.5

25

72
Min 15
Max 60

124
162

38
162

218.5
200 (3P)
315 (4P)

Safety clearances
A (*)

200

9.5

Door holes dimensions


A (*)

Min 295(3P)
Max 410(4P)

Min 295

270 (1)
316 (2)
135 (1)
158 (2)

15

205
F

325 (1)
364 (2)

A
B

Non-conductor

0
0

Base point

151

Metals

0
0

Electric conductor

100
60

162.5 (1)
182 (2)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
Removing the arc chutes needs 110mm safety clearance.
Removing terminal blocks needs 20mm safety clearance.

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections

Horizontal rear connection


27

20

115

115

20 150

N
X

115

76

93
161

13

38
= =

25

12,5

20

47
3 11.5

Low-voltage Distribution

233.5

14.5

Vertical rear connection


27

115

115

115
20
A

68

47

141

14.5

12.5
13
=
=

233.5
F

3 11.5

76
38
25

Front connection
20

12.5

115

230.5

475

115

115

76
25 25

13

12.5

219.5

3 11.5

3 11.5
12.5

Base point

Remarks: Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.

219
F

12.5

25 25

13

152

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
220.5 (3P)
335.5 (4P)

Min

400

220.5
308
154

Y
56
(*)

238. 5

X
200.5

Low-voltage Distribution

128

18

383.5

200

Min 60

400

Vertical installation on back board or frame

Horizontal installation on board or railway

X
2 11.5 x 22
11.5

10

175
10.5

110
103

175

283
F

167.5 (3P)
282.5 (4P)

162.5

Door holes dimensions

Safety clearances
A

Min 300 (3P)


Max 415 (4P)

Min 300

270 (1)
379 (2)

X 135 (1)

222 (2) 153.3 (1)

100
225
F

325 (1)
364 (2)

Non-conductor

A
B
Base point

153

0
0

Metals

0
0

Electric conductor

0
60

162.5 (1)
182 (2)

47 (1)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
Removing the arc chutes needs 110mm safety clearance.
Removing terminal blocks needs 20mm safety clearance.

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections

Horizontal rear connection


115

115

115

27
20

20

Y
76

93

296

13

38
= =

25

12.5

184

3 11.5

Low-voltage Distribution

47

20

14.5

298.5
F

Vertical rear connection


115

115

115
20
A

27

68

47
141

14.5

12.5
13
=
=

298.5

3 11.5

76
38
25

Front connection
115

20
12.5

151

400

224

115

76
25 25

13

12.5
3 11.5

3 11.5

Base point

Remarks: Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.

284
F

115

12.5

12.5
25 25

13

154

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

189 (3P)
304 (4P)

Dimensions

189
308
154

Y
191
150
260

161
Low-voltage Distribution

11

14

57

11

233

Horizontal installation on board or railway

200 (3P)
315 (4P)

200

11

Vertical installation on back board or frame

Y
X

9.5

25

72

124
162

38

Min 15
Max 60

162

218.5

200 (3P)
315 (4P)

Safety clearances

200

9.5

Door holes dimensions

A (*)

A (*)

Min 295 (3P)


Max 410 (4P)

Min 295

270 (1)
316 (2)
135 (1)
158 (2)

15

205
F

325 (1)
364 (2)
Non-conductor

A
B
Base point
155

0
0

Metals

0
0

Electric conductor

100
60

162.5 (1)
182 (2)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
Removing the arc chutes needs 110mm safety clearance.
Removing terminal blocks needs 20mm safety clearance.

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection

27
20

20

93

296

184
20
Low-voltage Distribution

298.5
F

150

150

115
52.5

135

150

115

115

12.5

14.5

52.5

17.5

17.5

12.5

25 25 25

47
4 11.5

332.5

100
12.5

217.5

12.5

25 25 25

14.5
47

Vertical rear connection

27

117.5

X
190.5

298.5
F

47

Base point

14.5
12.5
115

Remarks: Screws: M10 Class8.8

115

12.5

115

25

20

Fasten torque: 50Nm with gasket.

25
20

25

125

25

5 11.5

156

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
220.5 (3P)
335.5 (4P)

Min
400

220.5
308
154

Y
56
(*)

238.5

Low-voltage Distribution

200.5

128

18

383.5

200

Min 60

400

Vertical installation on back board or frame

Horizontal installation on board or railway

X
2 11.5 x 22
11.5

10

175
10.5

110
103

175

283
F
167.5 (3P)
282.5 (4P)

Door holes dimensions

Safety clearances
A

162.5

Min 300(3P)
Max 415 (4P)

300

270 (1)
379 (2)

X 135 (1)

222 (2) 153.3 (1)

100
225
F

325 (1)
364 (2)

Non-conductor

A
B

0
0

Base point
157

Metals

0
0

Electric conductor

0
60

162.5 (1)
182 (2)

47 (1)

(1) Without door frame


(2) With door frame
Remark: X axis and Y axis are the symmetry axis of 3-pole breaker's mask.
Removing the arc chutes needs 110mm safety clearance.
Removing terminal blocks needs 20mm safety clearance.

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection

27

20

20 150

93
161
20
Low-voltage Distribution

233.5
F
150

150

115
52.5

135

150

115

115
17.5

17.5

12,5

12.5
14.5

25 25 25

52.5

47
4 11.5
100

12,5
332.5 (4P)

12.5

25 25 25

14.5

217.5

47

27

Vertical rear connection

117.5

X
190.5

233.5
F

115

115

47

115

14.5
12.5

20
A

12.5

25

Base point

Remarks: Screws: M10 Class8.8


Fasten torque: 50Nm with gasket.

25
20

25

125

25
5 11.5

158

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions of Extend Current Transformers


N-phase Extend Current Transformer

130.75

60.39

60.5

Earth-leakage Current Transformer

130

115
210
256

51
46

280
340
390

92

72

22

147

8
M6

250

Ground Return Current Transformer


19
19

4X7

150

190

100

93

146
185
M6X20

45
50
70
90

Low-voltage Distribution

105.5

50
100

159

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions
711.5(4000A,5000A/4P,6300A/3P)
596.5(4000A,5000A/3P)

Min
320

352

Y
47
(*)

218.5
176

239.5

377

187

40

60

28

354

(*) Seperation position

Horizontal installation on board or railway

107

11

14

X
175

175

11
175

6
11

97

Low-voltage Distribution

Min
126

202

288

Base point

646.5(4000A,5000A/4P,6300A/3P)
531.5(4000A,5000A/3P)

Safety clearances

171.5

Door holes dimensions


B

Non-conductor

A
Base
point
B

0
0

Metals

0
0

Electric conductor

0
60

160

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Connections
Horizontal rear connection

311

Low-voltage Distribution

108
167
4

103

In(A)

4000A

20

5000A

30

6300A

30

40
370
F

Busbar dimensions

Rear panel holes dimensions

In=6300A

225.5

Base point
Remark: X axis and Y axis are the symmetry axis of breaker's mask.

161

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions of Extend Current Transformers

31

N-phase Extend Current Transformer

87
Low-voltage Distribution

44.5

108.5

Earth-leakage Current Transformer

130

115
210
256

51
46

280
340
390

92

72

22

147

8
M6

250

Ground Return Current Transformer


19
19

4X7

93

150

190

100

146
185
M6X20

45
50
70
90

50
100

162

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Dimensions of Power Supply Module and Signal Convert Module

90

Power Supply Module

53

Signal Convert Module

90

Low-voltage Distribution

70

53

70

Busbar Dimensions
In(A)

Ti=50

Ti=40
Qty

Size(mmmm)

630

405

400

405

400

405

400

800

505

500

505

500

505

500

1000

605

600

505

750

605

900

1250

805

800

805

800

605

900

1600

1005

1000

805

1200

805

1200

2000

1005

1500

1005

1500

1005

1500

2500

1005

2000

1005

2000

1005

2000

3200

10010

3000

10010

3000

10010

4000

4000

10010

5000

10010

5000

10010

6000

5000

12010

6000

12010

7200

6300

12010

7200

12010

8400

Remark: Ti stands for ambient temperature.


The material of busbar is bare copper.

163

Qty

Ti=60

Sectionmm2

SizemmmmSectionmm2

Qty Sizemmmm Sectionmm2

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Electrical Schematic Diagram


iTR336, iTR336E

Power Supple
Module

Seperation

Main
Circuit

Intelligent Control Unit

MN

MX XF

Charge
Indicator

MCH PF

Low-voltage Distribution

Open

Test

Connection

Close

Auxiliary Contacts

3-Position Indication Contacts

Note:
UM: Voltage test signal input
UN, UA, UB, UC stands for voltage signal form N, A, B, C.
Pow: Power input
Connect V1+, V2- to positive and negative poles on power supply module.
SWT: Fault-trip indication output
S1, S2, S4 are switch contacts, S1 is common port. Contact capacity: AC400V 5A
CT: External current transformer
C11, C12 are input port of CT
Remark 1: Intelligent control units work with power supply module. The input volatage of iAPU331 is AC220/230V;
The input voltage of iAPU332 is AC380/400V; The input volatage of iAPU332D is DC220V.
Remark 2: HDW9-1600N offers 4NO 4NC auxiliary contacts.HDW9-4000H1&H2 offer 4NO 4NC auxiliary contacts as standard.
8NO 8NC or 12NO 12NC offer as optional.
Remark 3: HDW9-1600N offers CT1, CD1 and CD2.
Remark 4: Voltage measure function only for iTR336E.
Remark 5: ZT100 and ZCT1 offer as optional. The CT port can connect with one kind of CT only.
Client Preparation
SB1-Closing button
SB2-Opening button
SB3-Emergency stop button
Component
MN-Under-voltage release

PF-Ready to close contact

CD1~CD3-Seperation position indication contacts

MX-Opening release

OF1~OF12-Auxillary contacts

CT1~CT3-Test position indication contacts

XF-Closing release

ZCT1-Earth-leakage CT

CE1~CE3-Connect position indication contacts

MCH-Electric motor

ZT100-Ground return CT
164

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Electrical Schematic Diagram


iTR336H, iTR336H-L

Power Supple
Module

Signal
Covert
Module

To Circuit Breaker

Seperation

ZCT1 or Z6100
N-phase CT

Connection

Test

Low-voltage Distribution

Main
Contacts

OFF

Main
Circuit

Intelligent Control Unit

MN MX XF

Charge
Indicator

MCH PF

ON

3-Position Indication Contacts

Auxiliary Contacts

Note:
UM: Voltage test signal input
UN, UA, UB, UC stand for voltage signal form N, A, B, C.
ZSI: Zone selective interlock
Z+, Z- are ZSI input port, AC24V .
Pow: Power input
Connect V1+, V2- to positive and negative poles on power supply module.
SWT: Fault-trip indication output
S1, S2, S4 are switch contacts, S1 is common port. Contact capacity: AC400V 5A
COM: Communication output
485+, 485- are communication output port; PE is protecting earth of the communication wire.
CT: External current transformer
C11, C12 are input port of CT
C21, C22 are input port of ZT100
C31, C32 are input port of ZCT1
Res: Remote reset
K1, K2 are the input port of remote reset.
SWT2: Fault-trip indication output 2
S11, S12, S14 are switch contacts, S11 is common port. Contact capacity: AC400V 5A
Client Preparation
SB1-Closing button
SB2-Opening button
SB3-Emergency stop button
SB4-Remote reset button

Component
MN-Under-voltage release
MX-Opening release
XF-Closing release
MCH-Electric motor

PF-Ready to close contact


OF1~OF12-Auxillary contacts
ZCT1-Earth-leakage CT
ZT100-Ground return CT

CD1~CD3-Seperation position indication contacts


CT1~CT3-Test position indication contacts
CE1~CE3-Connect position indication contacts

Remark 1: Intelligent control units work with power supply module. The input volatage of iAPU331 is AC220/230V;
The input voltage of iAPU332 is AC380/400V; The input volatage of iAPU332D is DC220V.
Remark 2: ZT100 and ZCT1 offer as optional. This CT port can connect with one kind of CT only.
Remark 3: For remote control, iCIO333 signal convert module is necessary. The contact capacity of the module is AC240V 10A, DC24V 10A.
Remark 4: HDW9-1600N offers 4NO 4NC auxiliary contacts.HDW9-4000H1&H2 offer 4NO 4NC auxiliary contacts as standard.
8NO 8NC or 12NO 12NC offer as optional.
Remark 5: Communication protocol is Modbus as standard. Profibus module and Devicenet module should order for additional.
Power supply module is necessary when communication module is used.
Remark 6: HDW9-1600N offers CT1, CD1 and CD2.
Remark 7: Res and SWT2 are optional parts, they are not compatible with each other.

165

Foxit PDF Editor (c) by Foxit Software Company, 2004

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

6300L
Electrical Schematic Diagram

iTR336, iTR336E
Power
Power Supply
Module
N-phase Circumscribed Transformer

Low-voltage Distribution

Open Close

Main
circuit

Intelligent Control Unit

Pin Function:
1# and 2#: auxiliary supply input terminal,
1# for positive terminal when being DC
3#, 4# and 5#: contact output of tripping
fault (4# refers to shared terminal);
contact capacity: AC 380V, 16A
6#, 7#, 8# and 9#: two groups of auxiliary
terminals with circuit breaker status;
contact capacity: AC 380V, 16A
20#: PE wire, protection earthing wire
25# ~26#: output for circumscribed transformer

Auxiliary
contact

Undervoltage Shunt
release
release

Closing
release

Charge
indicator

Electric
Motor

Auxiliary contacts

Remarks 1: terminal 27# ~ 28# of MN undervoltage release connect to main circuit


Remarks 2: MN, MX, XF and MCH shall be connected with different powers beacuse of
control supply voltage. Auxilary contact OF is 5a5b, MX shunt release and XF Closing
release have been tandem connected with normal open and normal close
auxiliary contacts in the factory.
Remarks 3: Terminal 35# can not only be connected to the power supply directly
(automatic pre-storing energy), but also to the power supply after adopting tandem
connection with normal open button (manual pre-storing energy)
Remarks 4: Terminal 6# ~ 7# can output normal close contacts,if the users put forward.

Components:
MN Undervoltage Release
MX Shunt Release
XF Closing Release
OF Auxiliary Contacts
MCH Electric Motor
SB1 Closing Button
SB2 Opening Button

Remarks 5: Power Module 1 is DC Power Module .No DC power Module when the
power is AC power supply.The input & output terminals cannot be connected reversely
(the draw-out type output terminal has been connected in the factory).
Remarks 6: The auxiliary contact is 5NO 5NC, 25# and 26# are circumscribed
transformer, applied for (3P+N) T type earthing failure protection.

166

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

6300L

Electrical Schematic Diagram


iTR336H

Power Supply
Module

To Breaker Enter-Wire

Low-voltage Distribution

ZCT1 or ZT100
N-phase Circumscribed
Transformer

Red

Signal Convert Module

Green

Open

Main
circuit

Intelligent Control Unit

Pin Function:
1# and 2#: auxiliary supply input terminal,
1# for positive terminal when being DC
3#, 4# and 5#: contact output of tripping
fault (4# refers to shared terminal);
contact capacity: AC 380V, 16A
6#, 7#, 8# and 9#: two groups of auxiliary
terminals with circuit breaker status;
contact capacity: AC 380V, 16A
10# and 11#: respective output wire of
RS485A and RS485B communication
12#,13#: alarm signal output
14#,15#: error tripping signal output
16#,17#: communication remote control
shunt release output
18#,19#: communication remote control make output
20#: PE Line, shielding earthing line.
21#: Neuter line voltage signal (N phase)
22#: voltage signal A phase
23#: voltage signal B phase
24#: voltage signal C phase
25#,26#: input of circumscribed transformer
Components:
MN Under-voltage Release
MX Shunt Release
XF Closing Release
OF Auxiliary Contact
MCH Electric Motor
ZCT1 Earth-leakage CT
ZT100 Earthing Transformer
167

Auxiliary Under
Shunt Closing Charge Electric
-voltage
Contact release release release indicator Motor

Close

Auxiliary Contacts

Remarks 1: terminal 27# ~ 28# of MN undervoltage release connect to main circuit


Remarks 2: MN, MX, XF and MCH shall be connected with different powers beacuse
of control supply voltage. Auxilary contact OF is 5NO5NC, MX Shunt-trip Release and
XF Closing release have been tandem connected with normal open and normal close
auxiliary contacts
in the factory.
Remarks 3: Terminal 35# can not only be connected to the power supply directly
(automatic pre-storing energy), but also to the power supply after adopting tandem
connection with normal open button (manual pre-storing energy)
Remarks 4: Terminal 6# ~ 7# can output normal close contacts,if the users put forward.
Remarks 5: iAPU332D is DC power supply module, and there is no such module
when the power is AC power supply.The input & output terminals cannot be connected
reversely (the draw-out type output terminal has been connected in the factory)
Remarks 6:The auxiliary contact is five-open and five-close, 25# and 26# are
circumscribed transformer, applied for (3P+N) T type earthing failure protection, or
connect Z CT1 or ZT100(should order extra)
Remarks 7: long-range control should add signal module and power module capacity
of signal module is: AC230V,10A; DC24V,10A
Remarks 8: communication agreement is Modbus. If use Profibus or other agreement,
it needs extra order. Power module and signal module needs extra order.

HDW9 Air Circuit Breaker


Standard: IEC 60947-2

Tripping Curves
Normal Protections

10000
5000

I R =(0.4~ 1) XIn+OFF

2000

t R =(15 ~480)S

1000
500
200
100

Low-voltage Distribution

50
20
t (s )

10
5

I 2 t ON
2
1

Isd =(0 .4~ 15 ) X In

0.5

0.4
0.3

0.2

0.2
0.1

I 2 t OFF

0.1

0.05

I i =2I n ~ 100KA

0.02
0.01

.2

.3

.4

.5

.6

.8

10

20

30

40

50 60 70 80 100

X In

200

KA

Ground Return Protection

10000
5000
2000
1000
500
200
100

lg=(0.2~1ln)/500A~1000A

50
20
t (s )

10
5

Ig = (0.2 ~1.0 )XIn+OFF


2
1
0.5

0.2
0.1

0.4
0.3
0.2

0.4
0.3
0.2

0.1

0.1

0.05

0.02
0.01

.1

.2

.3

.4

.5

.6

.8

10

20

30

40

X In

168

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Low-voltage Distribution

169

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Order Information

Select current

Select frame

Select current
Low-voltage Distribution

10:1000A Frame

Icu
42
Ics
30
Icw(0.5s) 30

02: 200A
04: 400A
06: 630A
08: 800A
10: 1000A

20:2000A Frame

Icu
Ics
Icw(1s)

1000A Frame

2000A Frame

3200A Frame

80
50
50

06: 630A
08: 800A
10: 1000A
12: 1250A
16: 1600A
20: 2000A

32:3200A Frame

Icu
Ics
Icw(1s)

80
80
65

20: 2000A
25: 2500A
32: 3200A

63:6300A Frame

Icu
Ics
Icw(1s)

6300A Frame

120
100
85

40: 4000A
50: 5000A
63: 6300A (Exclude 4P)

Doorframe and phase barrierare acquiescent


Product name

Frame

Rated current

W6

10: 1000

02: 200A

12: 1250A

40: 4000A

20: 2000

04: 400A

16: 1600A

50: 5000A

32: 3200

06: 630A

20: 2000A

63: 6300A (Exclude 4P)

63: 6300

08: 800A

25: 2500A

10: 1000A

32: 3200A

+ 20

W620163DHDD54L

16

W6
For example

170

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Select of breaker

Select form
Low-voltage Distribution

FH:Fixed horizonal
4:4P
FH:Fixed horizonal
3:3P

Select control loop

Select installation way

FH:Fixed horizonal
(1000AF-3200AF)

3:3P
4:4P

Motor mechanism (MCH)

Closing voltage release (XF)

DH:Drawout horizonal 3:3P


(1000AF-6300AF)
4:4P

Shunt release (MX)

Undervoltage release (MN)

DH:Drawout horizonal DH:Drawout horizonal


4:4P
3:3P
Undervoltage delayed release (MNR)

Auxiliary contact

Pole

Installation method

3: 3P

DH:Drawout horizonal (1000AF-6300AF)

D : DC220V

4: 4P

FH:Fixed horizonal

N : AC230V

Motor mechanism(MCH)+Closing release(XF)


(1000AF-3200AF)

V : AC400V

171

DH

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Select
Select
Shunt release (MX)
Auxilary contact
Undervoltage release

Select intelligent controller


Select intelligent controller

Low-voltage Distribution

Select
Motor mechanism (MCH)
Closing release (XF)

Select intelligent controller


Motor mechanism (MCH) + Closing release (XF) (Must Option)

ECW-L: basic protection

D : DC220V
N : AC230V
V : AC400V

ECW-L

Shunt release(MX) (At least choose one of the Acc.from MX/MN/MNR)


D : DC220V
N : AC230V
V : AC400V
5 : Without shunt
release

ECW-M: standard protection

ECW-M

Undervoltage release (MN/MNR)


N : AC230V
V : AC400V
P : With undervoltage delayed AC230V
T : With undervoltage delayed AC400V
5 : Without undervoltage release

ECW-H:advanced protection

Auxilary contact (Must Option)


4 : four open and four close (1000AF)
6 : five open and five close (2000-6300AF)
Shunt release(MX)

Undervoltage release

Auxilary contact

ESW series intelligent controller

D : DC220V

N : AC230V

4 : four open and four close

M : ECW-M

N : AC230V

V : AC400V

6 : five open and five close

L : ECW-L

V : AC400V

P : With undervoltage delayed AC230V

5 : Without shunt

T : With undervoltage delayed AC400V

release

ECW-H

H : ECW-H

5 : Without undervoltage release

172

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

The Indicator Diagram of HDW6 Air Circuit Breaker

7
8
Low-voltage Distribution

9
10

16

15

14

4
13

12

173

11

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Radio Accessories Guide


If you need more extend
function,choose accessories by
yourself.(Please see the appendix,
order goods on the basis of
accessories code.)

Low-voltage Distribution

174

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
HDW6-1000

Low-voltage Distribution

175

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
HDW6-2000

Volume
Drawout

Low-voltage Distribution

Fixed

Doorframe(Drawout)

Doorframe(Fixed)

176

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
HDW6-3200

Volume
Drawout

Low-voltage Distribution

Fixed

Doorframe(Drawout)

Doorframe(Fixed)

177

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Overall Dimensions
HDW6-6300

Volume

Low-voltage Distribution

Doorframe(Drawout)

Doorframe(Fixed)

178

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Technical Parameter
Common characteristics
Number of poles

3P, 4P

Rated insulation voltage Ui

800

Rated impulse withstand voltage Uimp

kV

Rated operational voltage Ue

400

Rated current
In(A)

In Frame(A)

1000

2000

Low-voltage Distribution

200

400

630

800

1000

1250

1600

2000

3200

6300

2500

3200

4000

5000

6300

Breaking capacity
Rated ultimate short circuit
breaking capacity lcu (kA)

42

80

80

120

Rated service short circuit


breaking capacity lcs (kA)

30

50

80

100

Rated Short-Time
Withstand Current Icw (0.5s)

30
50

65

85

Rated Short-Time withstand


current lcw (kA/1s)

Service life

179

Mechanical Life
with Maintenance

10000

10000

8000

5000

Mechanical Life
without Maintenance

2500

2500

2500

2500

Electric Life with


Maintenance

1000

1000

1000

800

Electric Life without


Maintenance

500

500

500

500

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Intelligent Controller
ECW-L
Function information
Protection

Use

Long time delay

Protect cable,prevent ageing

Short time delay

Protect equipment,prevent impedance short circuit

Instantaneous

Protect equipment,prevent metallicity short circuit

Earthing

Prevent fire

Low-voltage Distribution

ECW-L
protection characteristics

Setting range

Protection Characteristics for Overload Delay


Action current IR

(0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0)In+OFF

Delay time tL

30s, 60s, 120s, 240s

Protection Characteristics for Short-Delay Short Circuit


Action current Isd

(3, 4, 5, 6, 7, 8, 10)In+OFF

Action time tS

0.2s, 0.4s

Protection Characteristics for Instantaneous Short Circuit


Action current Ii

Setting range

Remark

(10, 11, 12, 14, 16, 18, 20) In+OFF

1000AF 2000AF

(7, 8, 9, 10, 11, 12, 14) In+OFF

3200AF 6300AF

Earthing protection
Action current Ig

(0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8)In+OFF

Actuation time tG

0.1s,0.2s,0.3s,0.4s

180

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Intelligent Controller
ECW-M
Function information
Protection

Use

Long time delay

Protect cable,prevent ageing

Short time delay

Protect equipment,prevent impedance short circuit

Instantaneous

Protect equipment,prevent metallicity short circuit

Earthing

Prevent fire

Measure
Current measurement
Voltage measurement
Low-voltage Distribution

Miscellaneous function
Pre-alarm
Self-diagnosis function
Fault log
Test function
ECW-M
protection characteristics

Setting range

Protection Characteristics for Overload Delay


Action current IR

(0.4~1.0I)n+OFF (>>100A)

Delay time tL

Fault current

Delay time

tR

15

30

60

120

240

480

1.5xIR

15

30

60

120

240

480

2xIR

8.4

16.9

33.8

67.5

135

270

7.2xIR

0.65

1.3

2.6

5.2

10.4

20.8

t=(1.5/N)2xtR
N=Fault current divided by the setting current I/IR
t=Delay Time of Failure Action
tR=Setting Value of Long-Delay Time
Protection Characteristics for Short-Delay Short Circuit
Action current Isd

(0.4~15)In+OFF Step setting 10kA below : 2A, 10kA above 10A

Action time tS

Inverse time Limit I2T


Fault current

Delay time
ts(s)

0.1

0.2

I2T: OFF

Min.delay(ms)

60

160 255 340

0.3

0.4

Max.delay

140 240 345 460

I2T:ON

Min.delay

60

I>8IR

Max.delay

140 240 345 460

I2T: ON

Inverse time limit delay t=(8IR)2/I2ts

160 255 340

I8IR
Protection Characteristics for Instantaneous Short Circuit
HDW6-1000

181

HDW6-2000

HDW6-3200

HDW6-6300

Action current Ii 2.0In~20kA+OFF


Earthing protection

2.0In~50kA+OFF

2.0In~75kA+OFF

2.0In~100kA+OFF

Action current Ig

(0.2~1.0)In+OFF

Actuation time tG

0.1s, 0.2s, 0.3s, 0.4s, OFF

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Intelligent Controller
ECW-H
Function information
Protection

Use

Long time delay

Protect cable,prevent ageing

Short time delay

Protect equipment,prevent impedance short circuit

Instantaneous

Protect equipment,prevent metallicity short circuit

Earthing

Prevent fire

Measure
Current measurement
Low-voltage Distribution

Voltage measurement
Power measurement
Harmonic wave measurement
Miscellaneous function
Pre-alarm
Self-diagnosis function
Fault log
Test function
Communication function
ECW-H protection characteristics
Parameter name

Setting range

Overload long time delay


Action current IR

OFF+0.4~1.0In

Protection curve

SI: Standard inverse time limit

Type selection

VI: Rapid inverse time limit


EI(G): Express inverse time limit(distribution)
EI(M): Express inverse time limit(electromotor)
HV: High-Pressure Welding Fuse Compatibility
I2t: Universal inverse time limit protection

Setting delay time

C01~C16

Protection Characteristics for Short Delay


Action Current of Inverse
Time Limit Is

OFF+(0.4~15)In

Action Current of Fixed


Time Limit Isd

OFF+(0.4~15)In

Delay Time of Fixed Time Limit tsd (0.1~0.4s)


Instantaneous protection Characteristics
Action current Ii HDW6-1000
2.0ln~20kA+OFF

HDW6-2000

HDW6-3200

HDW6-6300

2.0ln~50kA+OFF

2.0ln~75kA+OFF

2.0ln~100kA+OFF

Earthing protction Characteristics


Action current Ig

OFF+(0,2~1.0xIn)

Inverse time limit


shearing coefficient Cr

1.5~6, +OFF

Delay time tg

(0.1~0.4)s

182

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Accessories
Long-distance operation
Shunt release
Function introduce
When the breaker is stored,under prescriptive voltage,through long-distance remote
control operation,let the breaker break
Accessories parameter

Low-voltage Distribution

Rated operational voltage V

AC230V AC400V DC220V

Operation voltage

(0.7-1.1)Us

Consumption

300VA(AC) 40W(DC)

Breaking time

<30ms

Undervoltage release and undervoltage delay release


Function introduce
The undervoltage release automatically opens a circuit breaker when voltage drops to a value
ranging between 35% to 70% of the line voltage. after tripping,the circuit breaker cannot be
re-closed again when the voltage lowers than 35% or until returns to 85% of line voltage.
Undervoltage relay release lets the breaker break in 1s-5s(adjustable)
Accessories parameter
Rated operational voltage V

AC230V AC400V

Operational voltage

(0.35-0.7)Ue

Dependable closing voltage

(0.85-1.1)Ue

Unable closing voltage

0.35Ue

Consumption

12VA

Delay time

1s~3s

Closing release
Function introduce
When the breaker is stored,under prescriptive voltage,through long-distance remote control
operation,let the breaker close
Accessories parameter

183

Rated operational voltage V

AC230V AC400V DC220V

Operational voltage

(0.85-1.1)Us

Consumption

300VA(AC) 40W(DC)

Breaking time

<70ms

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Accessories
Motor mechanism
Function introduce
When the breaker is under breaking and power supply,motor mechanismis is automatic stored.
So under shunt release,undervoltage and closing release, let the breaker break and close
Accessories parameter
AC230V AC400V DC220V

Action voltage

(0.85-1.1)Us

Consumption

192VA(AC) 192W(DC)

Energy storage time

<5s

Low-voltage Distribution

Rated control power voltage V

Auxiliary contact
Function introduce
It is used for keeping watch on the breaker's status,connecting position signal light
and breaking indicator light
Accessories parameter
Utilization category

AC-15

Auxiliary contact default type

5NO 5NC (4NO 4NC for 1000AF)

Conventional thermal current Ith

6A

Auxiliary contact's energized


operational performance

Equal to circuit breaker operation


performance

Making&
breaking
capacity

Under
normal
conditions

Under
abnormal
conditions

DC13

I/Ie making

10

I/Ie breaking
U/Ue
COSor T0.95

1
1
0.3

1
1
6Pe*

U/Ue
I/Ie
COSor T0.95

10

1.1

1.1

1.1

0.3

6Pe*

Operation cycles

10

10

184

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Accessories
Transformer
N-phase Circumscribed Transformer
Function introduce
In the 3P+N earth connection,it is used for measure the current of the neutral phase
Note: 1. Only for 3P Breaker, and the Intelligent Controller should be 4P;
2. Max connect distance is 2M;
3. Customize according to the Intelligent Controller.
Low-voltage Distribution

Lock
Divide Release Lock
Function introduce
When the breaker is breaking,it could be lock in.
It is divided into three types: one lock and one key
two locks and one key
three locks and two keys

185

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Accessories
Connection

Cable Mechanical Interlock


Function introduce
It could connect two or three breakers to be linkage.
Note:The Max Horizonal installation distance is 2M;

Low-voltage Distribution

Connecting-rod Type Mechanical Interlock


Function introduce
It could connect two breakers to be linkage,one of the breakers is closing,
the other is breaking
Note: Only for Vertical intallation, and the Max installation distance is 0.9M;

Phase Barrier
Function introduce
Install in the middle of the breaker busbar,increase creepage distance, prevent to
engender electric arc

Intelligent controller accessories


DC Power Module
Function introduce
In the alternating current,supply auxiliary power supply for intelligent controllor
It is used for ST201 relay module or DC controllor power supply

186

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Accessories
Power Module
Function introduce
In the direct current,supply auxiliary power supply for intelligent controller

Low-voltage Distribution

Relay Module
Function introduce
Exporting signal element is used for failure warning or indication
Note:HDW6AP & HDW6R only for H Intelligent Controller, and they use together as a set.

Other accessories
Doorframe
Function introduce
Install on the power distribution cabinet door,increase IP protection grade to IP 40

187

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary connection diagram

Low-voltage Distribution

188

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary connection diagram

Power Supply
Module

Low-voltage Distribution

201 Relay Module

189

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary connection diagram

Low-voltage Distribution

190

HDW6 Air Circuit Breaker


Standard: IEC 60947-2

Auxiliary connection diagram

Power Module IV

201 Relay Module


Low-voltage Distribution

191

Motor Control and Protection Product


Overview
Contactor

Thermal Overload Relay

HDC6

194

HDR6

210

Current: 9-630A
Pole:3P
Coil Voltage:AC24-440V

Setting Current:0.1-630A
Trip class:10A ,10

HDC17-K

220

HDR17-18

Current:6-12A
Pole:3P,4P
Coil Voltage:AC24-400V

Setting Current:0.1-18A
Trip class:10A

HJX2

227

HJRS1D

HJRS2

Motor Control &


Protection
Motor
Control & Protection

Current:9-95A
Pole:3P
Coil Voltage:AC36-400V

223

233

Setting Current:0.1-93A
Trip class:10A,10

238

Setting Current:55-630A
Trip class:10A,10

192

Motor Control and Protection Product


Overview
Definite Purpose Contactor
HDC9

Control Relay
246

HDZ6

Current: 25-65A
Poles: 3P

Contact:
41,32

Application: Power factor


correction

Coil Voltage:
AC24-440V

248

Control Relay
HDZ8P

251

Contact:
2Z,3Z,4Z

Motor
Control&& Protection
Motor Control
Protection

256

Voltage:380V,400V

258

Frame Current: 32A


Setting Current: 0.1-32A

Magnetic Starter
HDS2

265

Frame Current: 13, 25, 95A


Setting Current: 1-93A

193

HDTL17
Poles:1P
Rated Current:16A

Motor Protector
HDP6

253

Rated working
voltage:120V,240V,400V
Relay Time:0.05s-24h

Coil Voltage:
AC6-220V
DC6-220V
HXJ9

HJSZ3

257

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Order Information
Product Name

Rated Current

Auxiliary Contact Coil Voltage

HDC6

09

11

09:9A

11:1NO+1NC

B:24V

Default:50HZ

00:0NO+0NC

7:50/60HZ

630:630A

Coil Frequency

X:440V

AC-3,380/400V

Instant Auxiliary Contact

Reference

Rated Power
(KW)

HDC6 09 11

12

5.5

HDC6 12 11

18

7.5

HDC6 18 11

25

11

HDC6 25 11

32

15

HDC6 32 11

40

18.5

HDC6 40 11

50

22

HDC6 50 11

65

30

HDC6 65 11

80

37

HDC6 80 11

95

45

HDC6 95 11

115

55

HDC6 115 00

150

75

HDC6 150 00

185

90

HDC6 185 00

225

110

HDC6 225 00

265

132

HDC6 265 00

330

160

HDC6 330 00

400

200

HDC6 400 00

500

250

HDC6 500 00

630

335

HDC6 630 00

Motor Control &


Protection
Motor
Control & Protection

Rated Current
(A)

Note: means coil voltage code.

Code Table of Coil Voltage


Coil Voltage (V)

24

36

48

110 127 220

230

240 380 400

415 440

50HZ

50/60HZ

B7 -

E7 F7

M7

N7

U7

Q7

V7

Note: 115-630AF refer to the actual situation.

194

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Order Information
Product Name

Rated Current Directional Conatctor Coil Voltage

HDC6

09

09:9A

B:24V

Default: 50HZ

7:50/60HZ

630:630A

X:440V

AC-3,380/400V
Rated Current
(A)

Coil Frequency

Instant Auxiliary Contact


Rated Power
(KW)

Reference

Motor
Control&& Protection
Motor Control
Protection

HDC6 09N

12

5.5

HDC6 12N

18

7.5

HDC6 18N

25

11

HDC6 25N

32

15

HDC6 32N

40

18.5

HDC6 40N

50

22

HDC6 50N

65

30

HDC6 65N

80

37

HDC6 80N

95

45

HDC6 95N

115

55

HDC6 115N

150

75

HDC6 150N

185

90

HDC6 185N

225

110

HDC6 225N

265

132

HDC6 265N

330

160

HDC6 330N

400

200

HDC6 400N

500

250

HDC6 500N

630

335

HDC6 630N

Note: means coil voltage code.

Code Table of Coil Voltage


Coil Voltage (V)

24

36

48 110 127

220 230 240 380 400 415 440

50HZ

50/60HZ

B7 -

M7

N7

U7

Q7

V7

E7 F7

Note: 115-630AF refer to the actual situation.

195

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Main Technical Parameter

HDC6-09 HDC6-12 HDC6-18 HDC6-25 HDC6-32 HDC6-40 HDC6-50 HDC6-65 HDC6-80 HDC6-95

Model

Co

Main circuit Characteristics


Rated Operational
le, AC-3
le, AC-1
Current

9A
20 A

Rated Isolation
Voltage (Ui)

690V

Ra
Vo

Rated Operational
Voltage (Ue)

690V

Ra
Vo

Number of Pole

Rated Operational
Power
ClassAC-3

220/240V
380/400V
415/440V
660/690V

2.2kW
4 kW
4 kW
5.5kW

3 kW
5.5kW
5.5kW
7.5kW

4 kW
7.5kW
9 kW
10 kW

5.5kW
11 kW
11 kW
15 kW

7.5kW
15 kW
15 kW
18.5kW

11 kW
18.5kW
22 kW
30 kW

15 kW
22 kW
25 kW
33 kW

18.5kW
30 kW
37 kW
37 kW

22 kW
37 kW
45 kW
45 kW

Electric durabilities
(10 thousand times)

100

100

100

100

80

80

80

80

60

60

Operating Rate
(time/h)

1200

1200

1200

1200

600

600

600

600

600

600

(10 thousand times)

1000

1000

1000

1000

800

800

800

800

800

800

Mechanical
Durabilities

18 A
32 A

25 A
40 A

32 A
50 A

40 A
60 A

50 A
80 A

65 A
80 A

80 A
125 A

95 A
125 A

Ra
Cu

Nu
25 kW
45 kW
45 kW
45 kW

Ra
Po
Cla

AC

Motor Control &


Protection
Motor
Control & Protection

AC-3

M
12 A
20 A

Me
Du

Coil

Rated Control Circuit 50Hz


Voltage (Us)
50/60Hz

24V,36V,48V,110V,127V,220V,380V,400V,415V,440V
24V,48V,110V,220V,230V,240V,380V,400V

Allowable Control
Circuit Voltage (Us)

Operation
Drop-out

85%~110% Us
20%~75% Us

Coil Power

Inrush VA
Sealed VA
Heat dissipation W

70
8
1.8~2.7

Ra
Vo

Al
Ci
110
11
3~4

200
20
6~10

Co

Terminal Wiring Ability

Flexible Wire
Without Terminal
Block

1 pc (Section of Connecting 1~4


Conduction mm2)
2 pcs (Section of Connecting
1~4
Conduction mm2)

1~4

1.5~6

1.5~10

2.5~10

2.5~25

2.5~25

2.5~25

4~50

4~50

1~4

1.5~6

1.5~6

2.5~10

2.5~16

2.5~16

2.5~16

4~25

4~25

Flexible Wire
With Terminal
Block

1 pc (Section of Connecting
1~4
Conduction mm2)
2 pcs (Section of Connecting
1~2.5
Conduction mm2)

1~4

1~6

1~6

1~10

2.5~25

2.5~25

2.5~25

4~50

4~50

1~2.5

1~4

1~4

1.5~6

2.5~10

2.5~10

2.5~10

4~16

4~16

Fixed Wire
Without Terminal
Block

1 pc (Section of Connecting
1~4
Conduction mm2)

1~4

1.5~6

1.5~6

1.5~10

2.5~25

2.5~25

2.5~25

4~50

4~50

2 pcs (Section of Connecting


1~4
Conduction mm2)

1~4

1.5~6

1.5~6

2.5~10

2.5~16

2.5~16

2.5~16

4~25

4~25

Fix
W
Bl

Co

Auxiliary Contact

Rated Thermal
Current (Ith)

10

Ra
Cu

Rated Operational
Voltage (Ue)

AC V
DC V
AC-15 VA
DC-13 W

400
230
360
33

Ra
Vo

Rated Control
Capacity

Ra
Ca

196

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

95

Contactor Type

HDC6-115 HDC6-150 HDC6-185 HDC6-225 HDC6-265 HDC6-330 HDC6-400 HDC6-500 HDC6-630

Rated Operational
Current

Main circuit Characteristics


le, AC-3
le, AC-1

115 A
200 A

Rated Isolation
Voltage (Ui)

1000V

150 A
200 A

185 A
275 A

225 A
275 A

265 A
315 A

330 A
380 A

400 A
450 A

500 A
630 A

630 A
800 A

40 kW
75 kW
80 kW
100kW

55 kW
90kW
100kW
110kW

63 kW
110kW
110kW
129kW

75 kW
132kW
140kW
160kW

100kW
160kW
180kW
220kW

110kW
200kW
220kW
280kW

147kW
250kW
280kW
335kW

200kW
335kW
375kW
450kW

Electric durabilities
(10 thousand times) 120

120

100

100

80

80

80

80

80

Operating Rate
(time/h)

600

600

600

600

600

300

300

300

1000

600

600

600

600

600

600

600

1200
20
14

1250
24
18

1650
22
20

Rated Operational
Voltage (Ue)
Number of Pole
Rated Operational
Power
ClassAC-3

Motor
Control&& Protection
Motor Control
Protection

AC-3
Mechanical
Durabilities

220/240V
380/400V
415/440V
660/690V

30 kW
55 kW
59 kW
80 kW

600

(10 thousand times) 1000

Coil
Rated Control Circuit 50Hz
Voltage (Us)
50/60Hz

110V,127V,220V,230V,240V,380V,400V,440V
110V,220V,380V (115-225AF)
85%~110% Us
20%~75% Us

Allowable Control
Circuit Voltage (Us)

Operation
Drop-out

Coil Power

550
Inrush VA
45
Sealed VA
Heat dissipation W 16

800
55
24

1200
13
12

Terminal Wiring Ability


Fixed Wire
Without Terminal
Block
Copper Bar

1 pc (Section of
Connecting
Conduction mm2)

95

120

150

185

240

240

2 pcs (Section of
Connecting
Conduction mm2)

150

240

2 pcs (Size mm2)

20*3

25*3

25*3

32*4

32*4

30*5

30*5

40*5

60*5

Auxiliary Contact
Rated Thermal
Current (Ith)

10

Rated Operational
Voltage (Ue)

AC V
DC V
AC-15 VA
DC-13 W

400
230
360
33

Rated Control
Capacity

197

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Directional Contactor

Rated Capacity (kW)

Rated Current (A)

AC-3

AC-3

690V

400V

690V

HDC6-09N

5.5

6.6

20

HDC6-12N

5.5

7.5

12

8.9

20

HDC6-18N

7.5

10

18

12

32

HDC6-25N

11

15

25

18

40

HDC6-32N

15

18.5

32

21

50

HDC6-40N

18.5

30

40

34

60

HDC6-50N

22

33

50

39

80

HDC6-65N

30

37

65

42

80

HDC6-80N

37

45

80

49

125

HDC6-95N

45

45

95

55

125

HDC6-115N

55

80

115

86

200

HDC6-150N

75

100

150

108

200

HDC6-185N

90

110

185

118

275

HDC6-225N

110

129

225

137

275

HDC6-265N

132

160

265

170

315

HDC6-330N

160

220

330

235

380

HDC6-400N

200

280

400

303

450

HDC6-500N

250

335

500

353

630

HDC6-630N

335

450

630

462

800

(Horizontal Installation)

Motor Control &


Protection
Motor
Control & Protection

400V

Rated Thermal
Current (A)
AC-1

Directional Contactor

198

HDC6 AC Contactor

Standard: IEC60947-1,IEC 60947-4-1

Option for Star Delta Starter

Contactor (HDC6-0995)
Max. Starting Frequency, 30 time/h; Max. Starting Time,30s

Motor
Control&& Protection
Motor Control
Protection

Motor
Class AC-3 50Hz 3-Phase Electromotor
Delta Connection

Contactor
Contactor
Straight Connection Delta Connection
KM2

KM3

KM1(3)

P (KW)

In (A)

IrD (A)

Type

Type

Type

Type

Setting Range (A)

1.5

3.5

HDC6-09

HDC6-09

HDC6-09

HDR6-18

1.8~2.5

2.2

HDC6-09

HDC6-09

HDC6-09

HDR6-18

2.5~3.6

6.6

HDC6-09

HDC6-09

HDC6-09

HDR6-18

3.5~4.8

8.5

HDC6-09

HDC6-09

HDC6-09

HDR6-18

4.5~6.3

5.5

11.5

HDC6-09

HDC6-09

HDC6-09

HDR6-18

5~7

7.5

15.5

HDC6-12

HDC6-12

HDC6-09

HDR6-18

9~12

18.5

11

HDC6-18

HDC6-18

HDC6-12

HDR6-18

11~15

11

22

13

HDC6-18

HDC6-18

HDC6-12

HDR6-18

11~15

15

30

16

HDC6-25

HDC6-25

HDC6-18

HDR6-32

14~18

18.5

37

22

HDC6-25

HDC6-25

HDC6-18

HDR6-32

18~25

22

44

26

HDC6-32

HDC6-32

HDC6-25

HDR6-32

23~32

30

60

35

HDC6-40

HDC6-40

HDC6-32

HDR6-95

30~40

37

72

40

HDC6-50

HDC6-50

HDC6-40

HDR6-95

37~50

45

85

47

HDC6-65

HDC6-65

HDC6-50

HDR6-95

37~50

55

105

58

HDC6-80

HDC6-80

HDC6-65

HDR6-95

55~70

75

138

78

HDC6-95

HDC6-95

HDC6-80

HDR6-95

63~80

199

Contactor
Thermal Overload Relay
Star Connection

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Option for Star-Delta Starter

Environmental Requirements
Ambient Temperature:
-5C~+40C
Altitude: 2000m
Pollution Level: III
No obvious shaking and shock
vibration

Wiring Diagram for Star-Delta Starter

U1

V1

W2

W1

L2

L3

Motor Control &


Protection
Motor
Control & Protection

KM1

(1)

KM3

U2

U1

V2

V1

W2

W1

KM3/5

Remote Control

21 67

68

13 14

13 22
KM2

KM3

55 14

KM1

KM2

KM2

21 56

KM1

A1 22

KM3

KM1

A2

L1

KM3/1
A2

14

A2

KM2

U2
V2

21 96

95

13

A1

A1 22

200

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Accessories

HDC6-995A Contactor Accessories

HFR6 Mechanical Interlock Module

HFD6 Top of Auxiliary Contact

HFC6 Side Auxiliary Contact

HFD6 Top of Auxiliary Contact

Motor
Control&& Protection
Motor Control
Protection

HDR6 Thermal Overload Relay


HFT6 Air Delayed Head

Top of Auxiliary Contact

Side Auxiliary Contact

Air Delayed Head

Mechanical Interlocking module

HX6 Coil

Thermal Overload Relay

201

2 poles: HFD6-11, HFD6-20, HFD6-02


4 poles: HFD6-22, HFD6-13, HFD6-31, HFD6-40, HFD6-04
2 poles: HFC6-11, HFC6-20, HFC6-02

Making time-delay: HFT6-20, HFT6-22, HFT6-24


Breaking time-delay: HFT6-30, HFT6-32, HFT6-34
HFR6-32 Adaptive to Product of 9-32A, Horizontal Installation
HFR6-95 Adaptive to Product of 40-95A, Horizontal Installation
Order reference: HX6+AF+Us+frequency
For example: HX632N7
HDR6-18
0.10-0.15A
0.12-0.18A

HDR6-32
6.3-9A
9-12A

14-18A

23-32A

HDR6-95
30-40A
37-50A

80-95A

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

HDC6-115630A Contactor Accessories

HX6 Coil

HFD6 Top of Auxiliary Contact

HFD6 Top of Auxiliary Contact

HFT6 Air Delayed Head


(Making time-delay)

HFT6 Air Delayed Head


(Breaking time-delay)

HDR6-185

Side Auxiliary Contact

Air Delayed Head

2 poles: HFD6-11, HFD6-20, HFD6-02


4 poles: HFD6-22, HFD6-13, HFD6-31, HFD6-40, HFD6-04

No Side Auxiliary Contact

Making time-delay: HFT6-20, HFT6-22, HFT6-24


Breaking time-delay: HFT6-30, HFT6-32, HFT6-34

Mechanical Interlocking module

Horizontal Installation and Vertical Installation

HX6 Coil

Spare parts, HX6-115-630 (Voltage AC:230V,


400V for Option)

Main Contact

Spare parts, HMC6-115~630

Thermal Overload Relay

HDR6-185

HDR6-630F

48-65A

145-200A

55-70A

180-250A

...

...

150-185A

460-630A

202

Motor Control &


Protection
Motor
Control & Protection

Top of Auxiliary Contact

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Auxiliary Contact
Installation
Position

Pole
2

Top

Side

Composition
NO
NC
0

Contact Point Layout

Reference

51

61

53

61

53

63

52

62

54

62

54

64

HFD6 02
HFD6 11
HFD6 20

51

61

71

81

53

61

71

81

53 61 83 71

83

52

62

72

82

54

62

72

82

54 62 84 72

84

HFD6 04
HFD6 13

53

61

73

83

53

63

73

83

54

62

74

84

54

64

74

84

HFD6 22
HFD6 31
HFD6 40

151
(182)

161 153
(172)(184)

161 153
(172) (184)

163
(174)

152
(181)

162 154
(171)(183)

162 154
(171) (183)

164
(173)

HFD6 02
HFD6 11
HFD6 20

Motor
Control&& Protection
Motor Control
Protection

HFT6 Air Delayed Contact


Installation
Position

Delay Type

Wiring Diagram
55

67

Making
time-delay
56

Top

65

Breaking
time-delay
66

203

68
57

58

Delay Range

Reference

0.1-3s

HFT6 20

0.1-30s

HFT6 22

10-180s

HFT6 24

0.1-3s

HFT6 30

0.1-30s

HFT6 32

10-180s

HFT6 34

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Mechanical Interlock Module


Horizontal Installation
Interlock Method

Contact Type

Mechanical Interlock

HDC6-9~32

HFR6 32 H

Electricity Interlock

HDC6-40~95

HFR6 95 H

HDC6-115~150

HFR6 FF H

HDC6-185~225

HFR6 GG H

Interlock
without Electricity

Reference

HDC6-265~330

HFR6 HH H

HDC6-400~500

HFR6 KK H

HDC6-630

HFR6 LL H

Vertical Installation (Mechanical without Electricity)


Contact Type
Bottom

Top

HDC6-115

HDC6-115

HFR6 FF V

or

HDC6-150

HFR6 FF V

HDC6-150

HDC6-185

HFR6 FG V

HDC6-225

HFR6 FG V

HDC6-265

HFR6 FH V

HDC6-330

HFR6 FH V

Interlock Device Reference

HFR6 FH V

HDC6-500

HFR6 FH V

HDC6-630

HFR6 FL V

HDC6-185

HDC6-185

HFR6 GG V

or

HDC6-225

HFR6 GG V

HDC6-225

HDC6-265

HFR6 GK V

HDC6-330

HFR6 GK V

HDC6-400

HFR6 GK V

HDC6-500

HFR6 GK V

HDC6-630

HFR6 GL V

HDC6-265

HDC6-265

HFR6 HK V

or

HDC6-330

HFR6 HK V

HDC6-330

HDC6-400

HFR6 HK V

HDC6-500

HFR6 HK V

HDC6-630

HFR6 HL V

HDC6-400

HFR6 HK V

HDC6-400

HDC6-500
HDC6-630

HDC6-500

HFR6 HK V

HDC6-630

HFR6 HL V

HDC6-500

HFR6 HK V

HDC6-630

HFR6 HL V

HDC6-630

HFR6 LL V

Motor Control &


Protection
Motor
Control & Protection

HDC6-400

Note: Vertical installation adopts mechanical Interlock Device equipped


with the interlock without electricity
204

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

HX6 Coil
Adaptive Contactor

Coil Voltage

Reference

115A-150A

220V

HX6 150 M

380V

HX6 150 Q

220V

HX6 225 M

380V

HX6 225 Q

265A-330A

220V

HX6 330 M

380V

HX6 330 Q

400A

220V

HX6 400 M

380V

HX6 400 Q

220V

HX6 500 M

380V

HX6 500 Q

220V

HX6 630 M

380V

HX6 630 Q

185A-225A

500A
630A

Motor
Control&& Protection
Motor Control
Protection

HMC6 Main Contact


Number of Pole

205

Contactor Current Specification Reference


115A

HMC6 115

150A

HMC6 150

185A

HMC6 185

225A

HMC6 225

265A

HMC6 265

330A

HMC6 330

400A

HMC6 400

500A

HMC6 500

630A

HMC6 630

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation

HDC6-9~32

35mm Rail

Amax

4.5

Cmax
C1max
C2max

Bmax
B1max
B2max

9/12

18

25/32

74.5

74.5

80

B (without accessory)

45.5

45.5

56.5

B1 (with a FC6)

58

58

69

B2 (with two FC6)

71

71

82

C (without accessory)

84

89

99.5

C1 (with FD6)

116

122

132

C2 (with FT6)

141

145

156

35

35

40

50/60

50/60

50/70

Motor Control &


Protection
Motor
Control & Protection

HDC6

HDC6-9~32N

Fmax
F1max

F2max
HDC6

9N/12N

18N

25N/32N

F (without accessory)

108

108

132

F1 (with a FC6)

119

119

143

F2 (with two FC6)

131

131

155

60

60

71.5

25

25

31.5

206

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation


HDC6-40~95
C2max
C1max
Cmax

35mm Rail

75mm Rail

Amax

B2max
B1max
Bmax

Motor
Control&& Protection
Motor Control
Protection

HDC6

40/50/65

80/95

127

127

B (without accessory)

75

85

B1 (with a FC6)

89

99

B2 (with two FC6)

102

112

C (without accessory)

118.5

127.5

C1 (with FD6)

150

160

C2 (with FT6)

175

185

105

105

59

67

105

105

40

40

5.5

5.5

6.5

6.5

HDC6-40~95N

Fmax
F1max
F2max

207

HDC6

40N/50N/65N

80N/95N

F (without accessory)

169

190

F1 (with a FC6)

182

203

F2 (with two FC6)

195

216

90

100.5

50

60.5

130

140

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation


HDC6-115-330

6.5

Amax

Amax

Type

X1

Ha

Ga

Bmax

Cmax

Bmax

11.5

X1

Cmax
H

X1

X1

(200-550V) (600-1000V)

Ga

Ha

167

163

172

37

20

M6

131

147

124

107

10

15

80

110~120

167

171

172

40

20

M8

131

150

124

107

10

15

80

110~120

HDC6-185

171

174

183

40

20

M8

131

154

127

113.5

10

15

80

110~120

HDC6-225

171

197

183

48

25

M10

131

172

127

113.5

10

15

80

110~120

HDC6-265

202

203

215

48

25

M10

147

178

147

141

10

15

96

110~120

HDC6-330

213

206

220

48

25

M10

147

181

158

145

10

15

96

110~120

Note:" f " reserved space to ensure draw-out coil can take out easily.

HDC6-400~500
S

Amax

Bmax

Cmax

Bmax

Cmax

Ga

H
L

P
Amax

Type

X1

Ha

13.5

X1

8.5

X1

X1

(200-550V) (600-1000V)

Ga

Ha

HDC6-400

213

206

220

48

25

M10

146

181

158

145

15

20

80

170~180

HDC6-500

223

233

233

55

30

M10

150

208

172

146

15

20

80

170~180

Note:" f " reserved space to ensure draw-out coil can take out easily.

208

Motor Control &


Protection
Motor
Control & Protection

HDC6-115
HDC6-150

HDC6 AC Contactor
Standard: IEC60947-1,IEC 60947-4-1

Overall Dimension of Installation


HDC6-630
S

10.5

Bmax

Ha

15.5

X1

X1

Ga
P

Cmax

Amax

Type

Amax

Bmax

Cmax

HDC6-630

309

304

256

80

40

M12

X1

181

264

202

155

X1

(200-550V)

20

(600-1000V)

30

Ga

Ha

180

180~190

Wiring Diagram
HDC6-09~95

209

A1

22

A2

13/NO

21/NC

14

5
6
W

21/NC
22

A1

6
W

A2

3
4

1
2

L3
5
6

L2
3
4

2T1 4T2 6T3

L1

A2

1L1 3L2 5L3

A1

HDC6-115N~630N
(Horizontal Installation, Mechanical Interlock)

A1

HDC6-115~630

L3
13/NO
14

L2

A2

14NO 22NC

L1

6T3

A2 2T1 4T2

13NO 21NC

5L3

A1

A1 1L1 3L2

HDC6-09N~95N
(Horizontal Installation, Mechanical +Electrical Interlock)

A2

Motor
Control&& Protection
Motor Control
Protection

Note:" f " reserved space to ensure draw-out coil can take out easily.

HDR6 Thermal Overload Relay


Order Information

Product Type

Frame Current

Setting Current

HDR6

18

P15

18:18A

P150.1-0.15

630:630A

630:460-630A

Installation Type

Default:None
F:Independent installation

P means decimal point


Range for Setting
Current

Fuse used for Matching


with Relay
aM
gG

0.10-0.15A

0.25

HDC6-09~18

HDR6 18 P15

0.12-0.18A

0.25

HDC6-09~18

HDR6 18 P18

0.18-0.25A

0.5

HDC6-09~18

HDR6 18 P25

0.25-0.36A

HDC6-09~18

HDR6 18 P36

0.35-0.50A

HDC6-09~18

HDR6 18 P5

0.50-0.70A

HDC6-09~18

HDR6 18 P7

0.63-0.90A

HDC6-09~18

HDR6 18 P9

0.90-1.20A

HDC6-09~18

HDR6 18 1P2

1.20-1.80A

HDC6-09~18

HDR6 18 1P8

1.80-2.50A

HDC6-09~18

HDR6 18 2P5

2.50-3.60A

10

HDC6-09~18

HDR6 18 3P6

3.50-4.80A

16

HDC6-09~18

HDR6 18 4P8

4.50-6.30A

16

HDC6-09~18

HDR6 18 6P3

5-7A

12

20

HDC6-09~18

HDR6 18 7

6.3-9A

12

20

HDC6-09~18

HDR6 18 9

9-12A

16

25

HDC6-09~18

HDR6 18 12

11-15A

20

35

HDC6-09~18

HDR6 18 15

14-18A

20

35

HDC6-09~18

HDR6 18 18

6.3-9A

12

20

HDC6-25~32

HDR6 32 9

9-12A

16

25

HDC6-25~32

HDR6 32 12

12-18A

20

35

HDC6-25~32

HDR6 32 18

18-25A

25

50

HDC6-25~32

HDR6 32 25

23-32A

40

63

HDC6-25~32

HDR6 32 32

18-25A

25

50

HDC6-40~95

HDR6 95 25

23-32A

40

63

HDC6-40~95

HDR6 95 32

30-40A

40

100

HDC6-40~95

HDR6 95 40

37-50A

63

100

HDC6-40~95

HDR6 95 50

48-65A

63

100

HDC6-40~95

HDR6 95 65

55-70A

80

125

HDC6-40~95

HDR6 95 70

63-80A

80

125

HDC6-40~95

HDR6 95 80

80-95A

100

160

HDC6-40~95

HDR6 95 95

Matched Contactor

Reference

Adaptive Thermal Relay Type

Reference

HDR6-18

HDR6 18 J

HDR6-32

HDR6 32 J

HDR6-95

HDR6 95 J

210

Motor Control &


Protection
Motor
Control & Protection

Base

HDR6 Thermal Overload Relay


Order Information

Range for Setting


Current

Motor
Control&& Protection
Motor Control
Protection

211

Fuse used for Matching with Relay

48-65

aM
80

gG
100

55-70

80

63-80

Matched Contactor

Reference

HDC6-115~185

HDR6 185 65

100

HDC6-115~185

HDR6 185 70

80

100

HDC6-115~185

HDR6 185 80

75-95

100

125

HDC6-115~185

HDR6 185 95

90-115

125

200

HDC6-115~185

HDR6 185 115

105-135

160

200

HDC6-115~185

HDR6 185 135

120-150

160

200

HDC6-115~185

HDR6 185 150

130-160

160

250

HDC6-115~185

HDR6 185 160

150-185

200

250

HDC6-115~185

HDR6 185 185

145-200

200

400

HDC6-225~630

HDR6 630 200F

180-250

250

400

HDC6-225~630

HDR6 630 250F

230-320

355

500

HDC6-225~630

HDR6 630 320F

290-400

400

630

HDC6-225~630

HDR6 630 400F

350-480

500

800

HDC6-225~630

HDR6 630 480F

460-630

630

800

HDC6-225~630

HDR6 630 630F

HDR6 Thermal Overload Relay


Introduction for Functions

Coil Rapid Wiring Terminal


Tripping Indication,
Test and Manual Reset Button

Reset Setting Knob


TEST
TRIP

RESET
14

18

STOP
H

16

Current Setting Button

Stop Button
96 NC 95

1.Reset Setting Knob

N0 97

4T2

Motor Control &


Protection
Motor
Control & Protection

2T1

98

6T3

2.Tripping Indicator, Test and Manual Reset Button

Manual Reset for Arrow


Pointing to H
Automatic Reset for Arrow
Pointing to A

After the operation of tripping indication and


TEST
TRIP

RESET

4.Current Setting Button

3.Stop Button
Make NC Contact operate, but

Set the value of setting current for rated


14

electromotor.

16

not influence NO contact. After


pressing Stop Button, cut control
circuit off and the electromotor
stops working.

18

STOP

thermal overload relay, yellow button to Trip


position means tripping;
After the operation of manual reset, the reset is
realized to put yellow button back to Reset
position;
Implement the test to simulate the tripping (use NO
and NC Contact to operate) and check the control
circuit. When carrying out the test under manual
reset state, put back to Reset position after
reaching Trip. Automatically rebound to Reset
after switching to Trip for automatic reset.

212

HDR6 Thermal Overload Relay


Technical Parameter

Motor
Control&& Protection
Motor Control
Protection

213

HDR6 Thermal Overload Relay

Tripping Characteristics and Wiring Diagram

Tripping Characteristics
No.

Mulriple of Setting
Current

Tripping Time

Trip class 10A


Tripping Characteristics for Current Balance

Trip class 10

1.05

Non-tripping within 2h

1.2

3
4

Initial Condition

Ambient
Temperature

Non-tripping within 2h

Without previous load

+20C

Tripping within 2h

Tripping within 2h

After No.1 Test

1.5

2min

4min

After No.1 Test

7.2

2sTp10s

4sTp10s

Without previous load

+20C

+20C

Tripping Characteristics for Current Imbalance


Any 2-Phase, 3rd Phase
1

1.0

0.9

Non-tripping within 2h

Non-tripping within 2h

Without previous load

1.15

Tripping within 2h

Tripping within 2h

After No.1 Test

Wiring Diagram

Tripping Characteristics

Motor Control &


Protection
Motor
Control & Protection

Average Value (Environmental Temperature: 20C)


80
50

Operation time

(Min)

(s)

30
20

FU

10
8
5
3
2

KM

Without previous load

60
40
30
20

2-Phase (Phase Failure)


Without previous load

10
8
6
4
3
2
0.8
0.6
0.4
0.3

SB1

FR

With previous load

A1
A2

SB2

95 97
96 98

W
M

0.8 1

1.5

5 6 7 8 9 10

Multiple of Setting Current

15

Xle(A)

214

HDR6 Thermal Overload Relay


Installation Methods

HDR6-9~95
Assembly Installation

1L1

3L2

5L3

12NO 21NC

2T1

4T2

6T3

14NO 22NC

A1

A2

A2

95

STOP 97

96

98

TRIP RESET

1L1

3L2

5L3

2T1

4T2

5T3

Motor
Control&& Protection
Motor Control
Protection

This wire is the coil rapid wiring terminal,


which can be used as the assembly with
the contactor. When two are completely
connected, it is to ensure that the screw
in A2 contact point of the contactor coil
is tightened.

1L1

3L2

5L3

12NO 21NC

2T1

4T2

6T3

14NO 22NC

A1

A2

95

STOP 97

TRIP RESET

1L1

3L2

5L3

2T1

4T2

5T3

If this wiring terminal is not used,


it can be cut short and then insulating
tape can be used in conductive parts.

96

215

98

HDR6 Thermal Overload Relay


Installation Methods

HDR6-9~95
Independent Installation

HDR6-185
Assembly Installation

Independent Installation

Motor Control &


Protection
Motor
Control & Protection

Note: It also can be fixed by screws.


Fasten the screws.

HDR6-630/F
It only can be fixed by 75mm railway or screws.

216

HDR6 Thermal Overload Relay


Overall Dimension of Installation

HDR6-18 Assembly Installation

HDR6-18 Independent Installation

74

35

86max

127

77max

73max

35
46max

46.2

10.6 10.6

69max

46

Assembly Installation for HDR6-18 and HDC6-09, 12 , 18


HDC6-12

HDC6-18

84

84

89

HDR6-32 Independent Installation

57

137

103max

44
57max

78max

65.7
95max
101max

217

74

Motor
Control&& Protection
Motor Control
Protection

HDR6-32 Assembly Installation

35
86max

HDC6-09

13.6 13.6

55

HDR6 Thermal Overload Relay


Overall Dimension of Installation

HDR6-95 Assembly Installation

HDR6-95 Independent Installation

85max

74.1

182

35
91max

51

85max
62.1
111max
A

51
78max

118.5max

21 21
72

Assembly Installation for HDR6-95 and HDC6-40~95


A

HDC6-40

HDC6-50

HDC6-65

HDC6-80

HDC6-95

118.5

118.5

118.5

127.5

127.5
Motor Control &
Protection
Motor
Control & Protection

218

HDR6 Thermal Overload Relay

Overall Dimension of Installation

HDR6-185 Independent Installation


B

105max
40
40
37
37

132max

35.5

103max

77.9

82.5

77.9

76

37

76

37

132max
37

105max

Assembly Installation for HDR6-185 and HDC6-115~185


HDC6-150

HDC6-185

248

253

257

167

167

171

172

172

183

181max

150max

108

4x 7

70

130

171max

144

75

Motor
Control&& Protection
Motor Control
Protection

HDC6-115

HDR6-630/F Independent Installation

50

219

37

103

HDR6-185 Assembly Installation

2x 7

HDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Function

HDC17-K AC contactor provide:


Remote make & break of circuits
Frequent start and stop of motors

Order Information
Moter
P(kW) 380V

Rated
current(A)

2.2

Auxiliary contact

Main contact

12

Reference

NC

NO

NC

HDC17K63010*

HDC17K63001*

HDC17K64000*

HDC17K62200*

HDC17K93010*

HDC17K93001*

HDC17K94000*

HDC17K92200*

HDC17K123010*

HDC17K123001*

HDC17K124000*

Motor Control &


Protection
Motor
Control & Protection

NO

Reference Description
HDC17-K

30

10

*
Coil Frequency
Coil Voltage
Auxiliary contact
Main contact
Rate current
Model

Coil voltage code


coil voltage

24V

36V

110V

127V

220V

380V

400V

Coil frequency code


coil frequency

50Hz

60Hz

220

HDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Technical Data
Model

HDC17-K06

HDC17-K09

HDC17-K12

Main circuit characteristics


Rated operational current 380V/400V, AC-3

12

380V/400V, AC-4

2.6

3.5

660V/690V, AC-3

3.5

1.5

1.2

Rated operational voltage

220/230, 380/400, 660/690

Rated insulation voltage

690

Rated conventional thermal current

16

660V/690V, AC-4

Pole

20

3, 4

Power of controlled

220V/230V, AC-3

kW

1.5

2.2

3-phase cage motor

380V/400V, AC-3

kW

2.2

5.5

7.5

Electric durabilities

660V/690V, AC-3

kW

AC-3

104 operations

100

cycles/h

1200

Operating rate
Electric durabilities

AC-4

Motor
Control&& Protection
Motor Control
Protection

Operating rate
Mechanical durabilities

10 operations

20

cycles/h

600

10 cycles

Matched Fuse
Cable connection

1000
HRT16-16

Inflexible cable

number of piece

Cross Section of Cable mm2

HRT16-20

2
4

Coil
Coil voltage(Us)

AC 24,36,110,127,220,380,400

Operational voltage

85%110% Us

Drop-out voltage

20%75% Us

Inrush

VA

30

Sealed

VA

4.5

Rated conventional thermal current

690

Rated insulation voltage

10

Rated operational current 380V, AC-15

0.95

220V, DC-13

0.15

AC-15

VA

360

DC-13

33

Auxliary contact

Control capacity

221

HDC17-K Mini AC Contactor


Standard: IEC 60947-4-1

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35
Altitude: 2000 m
Humidity: Maximum temperature is +40, air relative humidity of not more than 50%,at a lower
temperature allows a higher relative humidity. For example, 20, when up to 90%, and
occasionally due to temperature changes resulting from Gel should take special measures
Pollution Level: 3
Installation Type:
Installation position: should be installed in the absence of a significant shake and shock and
vibration place

Install Location

Motor Control &


Protection
Motor
Control & Protection

Overall Dimensions

222

HDR17-18 Thermal Overload Relay


Standard: IEC 60947-4-1

Function

HDR17 series thermal overload relay provide:


Protection of circuits and motors against overload
Protection of circuits and motors against phase loss
Motor starters installation in association with contactors

Order Information
Reference Description
HDR17

18

P15
Setting current
Rated current
Model

Type

Rated
insulation
voltage
Ui V

HDR17-18 690
Motor
Control&& Protection
Motor Control
Protection

223

Frame size
rated current

Range of current
setting A

Reference

Recommended
contactor

18

0.1~0.13~0.15

HDR1718P15

HDC17-K-9~18

0.12~0.16~0.18

HDR1718P18

HDC17-K-9~18

0.18~0.2~0.25

HDR1718P25

HDC17-K-9~18

0.25~0.32~0.36

HDR1718P36

HDC17-K-9~18

0.35~0.4~0.5

HDR1718P5

HDC17-K-9~18

0.5~0.6~0.7

HDR1718P7

HDC17-K-9~18

0.63~0.72~0.9

HDR1718P9

HDC17-K-9~18

0.9~1~1.2

HDR17181P2

HDC17-K-9~18

1.2~1.6~1.8

HDR17181P8

HDC17-K-9~18

1.8~2~2.5

HDR17182P5

HDC17-K-9~18

2.5~3.2~3.6

HDR17183P6

HDC17-K-9~18

3.5~4~4.8

HDR17184P8

HDC17-K-9~18

4.5~5~6.3

HDR17186P3

HDC17-K-9~18

5~6~7

HDR17187

HDC17-K-9~18

6.3~7.2~9

HDR17189

HDC17-K-9~18

9~10~12

HDR171812

HDC17-K-9~18

11~13~15

HDR171815

HDC17-K-9~18

14~16~18

HDR171818

HDC17-K-9~18

HDR17-18 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data

Temperature compensation

-10~+55

Trip class 10A

HDR17-18

Rated insulation voltage Ui V

690V

Structure characteristics


Overload protection
Phase-failure protection
Manual reset

Protection Function

Automatic reset
Stop button
Test button

Trip direction

Tolerance on slope in any direction

22.5

Control circuit
Utilization category

AC-15

Rated frequency Hz

50

50

50

Rated insulation voltage Ui V

690

690

690

690

Rated operational voltage Ue V

220/230

380/400 660/690

Rated operational current Ie A

1.64/1.57 0.95/0.9 0.55/0.52

0.23/0.22

Conventional free air thermal current Ith A

Contact circuit

Utilization category

AC-15

DC-13

Rated frequency Hz

50

Rated insulation voltage Ui V

690

690

Rated operational voltage Ue V

660/690

220/230

Rated operational current Ie A

Conventional free air thermal current Ith A

DC-13
Motor Control &
Protection
Motor
Control & Protection

220/230

224

HDR17-18 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Trip Characteristic

Sequence

Multiples of
setting current

Trip time
Trip class 10A

Initial condition

Ambient
temperature

Limits of operation of relays when energized on all poles


1

1.05

>2h

From cold state

1.2

<2h

From hot state(immediately


following sequence 1 test)

1.5

2min

From hot state(immediately


following sequence 1 test)

7.2

2sTp10s

From cold state

+20

+20

Limits of operation when energized on two poles


Motor
Control&& Protection
Motor Control
Protection

Any two The thirdpoles


pole

225

1.0

0.9

>2h

From cold state

1.15

<2h

From hot state(immediately


following sequence 1 test)

+20

HDR17-18 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work conditions
Ambient temperature: -10~+55, daily average temperature 35
Altitude: 2000m
Humidity: The relative humidity of the installtion position shall not exceed 50% when the maximum
temperature reaches +40. But there can be higher relative humidity under lower temperature.
For example, it can reach 90% when temperature is at 20. Special measures should be taken
against condensation occuring on product surface caused by temperature change
Pollution class: 3

Installation conditions
Installation Type:
Installation position: Unobvious shake and impact shock is necessary. Vertically mounting.
Tolerance on slope in any direction shall not exceed 22.5

22.5

22.5

Motor Control &


Protection
Motor
Control & Protection

Wire Connection Picture


FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button

Overall Dimensions

HDR17-18

226

HJX2 AC Contactor
Standard: IEC 60947-4-1

Function

HJX2 AC contactors provide:


Remote make & break of circuits
Frequent start and stop of motors

Order Information
Auxiliary contact

Rated current(A)

Motor P(kW) 380V


5.5

NO

7.5

12

10

18

15

25

18.5

32

NC

Reference

Motor
Control&& Protection
Motor Control
Protection

HJX2910*

HJX2901*

HJX21210*

HJX21201*

HJX21810*

HJX21801*

HJX22510*

HJX22501*

HJX23210*

HJX23201*

30

40

HJX24011*

33

50

HJX25011*

37

65

HJX26511*

45

80

HJX28011*

55

95

HJX29511*

Reference Description
HJX2

10

Coil Frequency
Coil Voltage
Auxiliary contact
Rate current
Model

Coil voltage code


coil voltage

24V

36V

110V

127V

220V

380V

400V

Coil frequency code


coil frequency

227

50Hz
5

60Hz
6

HJX2 AC Contactor
Standard: IEC 60947-4-1

Technical Data
Model

HJX2-09 HJX2-12 HJX2-18 HJX2-25 HJX2-32 HJX2-40 HJX2-50 HJX2-65 HJX2-80 HJX2-95

Main circuit characteristics


Rated operational voltage

400, 690

Rated insulation voltage

690

Conventional thermal current

25

25

32

40

50

60

80

80

125

125

Rated operational

400V AC-3 A

12

18

25

32

40

50

65

80

95

current

400V AC-4 A

3.5

7.7

18

21

34

39

42

49

55

690V AC-3 A

6.6

8.9

12

8.5

12

18.5

24

28

37

44

690V AC-4 A

1.5

3.8

4.4

7.5

12

14

17.3

21.3

5.5

7.5

11

15

18.5

22

30

37

45

Power of controlled 400V, AC-3 kW


3-phase cage

690V, AC-3 kW

5.5

7.5

10

15

18.5

30

33

37

45

55

motor

400V, AC-4 kW

2.2

5.5

7.5

7.5

11

15

18.5

22

4
AC-3 10 operations 100

80

80

60

4
AC-4 10 operations 20

Electric durabilities

20

15

10

1000

800

800

600

AC-3 cycles/h

1200

600

600

600

AC-4 cycles/h

300

300

300

300

104 cycles

Mechanical durabilities
Operating rate

Cable connection cross section

mm2

1.5

1.5

2.5

10

16

16

25

35

Coil
Coil voltage(Us)

AC24,36,110,127,220,380,400

Operational voltage

85%~110%Us

Drop-out voltage

20%~75%Us

Inrush

VA

70

110

200

Sealed

VA

11

24

Heat dissipation

2.7

10

Front mount

HF4

Side mount

HFC6

Front mount

HSK4

Accessories
Auxiliary contact
Time-delay block

HFR632H

Mechanical Interlock
Rated conventional thermal current

10

Rated operational voltage AC

400

DC

230

Rated control capacity

AC-15 VA

360

DC-13 W

33

HFR695HX

228

Motor Control &


Protection
Motor
Control & Protection

Matched Fuse

HRT16-20 HRT16-20 HRT16-32 HRT16-40 HRT16-50 HRT16-63 HRT16-80 HRT16-80 HRT16-100 HRT16-125

HJX2 AC Contactor
Standard: IEC 60947-4-1

HJX2 Contactor Accessories


Mechanical interlocking module

Top of auxiliary contact


Side auxiliary contact
Air delay head

Thermal overload relays

Contactor
Motor
Control&& Protection
Motor Control
Protection

9
Top of
auxiliary
contact

Side
auxiliary
contact

Air
delayed
head

229

12

18

25

32

40

50

2 Poles: HF411, HF402, HF420


4 Poles: HF404, HF413, HF422, HF431, HF440

2 Poles: HFC611, HFC602, HFC620

Making time-delay: HSK420, HSK422, HSK424


Breaking time-delay: HSK430, HSK432, HSK434

Mechanical
interlocking
module

9-32A: HFR632H
40-95A: HFR695HX

Thermal
overload
relays

HJRS1D-25
0.1-0.16A
...
17-25A

HJRS1D-36
23-32A
30-40A

HJRS1D-93
23-32A
...
80-93A

65

80

95

HJX2 AC Contactor
Standard: IEC 60947-4-1

Accessories
HF4 Top of auxiliary contact
Pole

Contact
NO

NC

Wiring diagram
53

61

HF411
54

2P

0
4P

Reference

62

51

61

52

62

53

63

54

64

HF402

HF420

51 61 71

81

52 62 72

82

HF404
53 61 71 81

HF413
54 62 72 82
53 61 71

83

HF422
54 62

84

73

83

54 62

74

84

Motor Control &


Protection
Motor
Control & Protection

72

53 61

HF431

53 63 73 83

HF440

54 64 74 84

HSK4 Air delayed head


Delay Type

Wiring diagram
55

Making timedelay

56

65

Breaking
time-delay

66

67

68

Delay Range

Reference

0.1-3S

HSK420

0.1-30S

HSK422

10-180S

HSK424

0.1-3S

HSK430

0.1-30S

HSK432

10-180S

HSK434

57

58

HFC6 Side auxiliary contact


Pole

2P

Contact
NO

NC

Wiring diagram
11
(32)

21
(42)

12
(31)

22
(41)

23
(44)

13
(34)

24
(43)

14
(43)

23
(44)

11
(32)

24
(43)

12
(31)

Reference
HFC602

HFC611

HFC620

230

HJX2 AC Contactor
Standard: IEC 60947-4-1

Accessories
Mechanical interlocking module
Contactor Specifications

Reference

HJX2-9~32

HFR632H

HJX2-40~95

HFR695HX

Working Conditions

Ambient temperature:-5+40, the daily average temperature 35

Altitude: 2000 m
Humidity: Maximum temperature is +40, air relative humidity of not more than
50%, at a lower temperature allows a higher relative humidity. For example, 20,
when up to 90%, and occasionally due to temperature changes resulting from Gel
should take special measures
Pollution Level: 3
Installation Type:
Installation position: should be installed in the absence of a significant shake and
shock and vibration place

Motor
Control&& Protection
Motor Control
Protection

InstallLocation

231

HJX2 AC Contactor
Standard: IEC 60947-4-1

Overall Dimensions

Unit:mm

HJX2-09~32

HJX2-40~95

Motor Control &


Protection
Motor
Control & Protection

Product Type

Amax

Bmax

Cmax

C1max

C2max

HJX2-09~12

47

76

82

115

115

35

50/60

4.5

HJX2-18

47

76

87

120

120

HJX2-25

57

86

97

130

130

40

50/60

4.5

HJX2-32

57

86

102

135

135

HJX2-40~65

77

129

116

149

149

40

100/110

6.5

HJX2-80~95

87

129

127

160

160

Note: C1max is auxiliary contact group +HF4 C2max is air-delay contact+HSK4

232

HJRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

HJRS1D relay provide:


Protect motor and circuit
Possess overload and phase failure protection functions.

Order Information
Reference Description
HJRS1D 25

P16

Setting current
Rated current
Model

Current
setting(A)

Reference

Recommended
contactor

Recommended
fuse

25

0.1~0.16

HJRS1D25P16

HJX2-09~32

HRT16-4

0.16~0.25

HJRS1D25P25

HJX2-09~32

HRT16-4

0.25~0.4

HJRS1D25P4

HJX2-09~32

HRT16-4

0.4~0.63

HJRS1D25P63

HJX2-09~32

HRT16-4

0.63~1

HJRS1D251

HJX2-09~32

HRT16-4

1~1.6

HJRS1D251P6

HJX2-09~32

HRT16-4

1.6~2.5

HJRS1D252P5

HJX2-09~32

HRT16-6

2.5~4

HJRS1D254

HJX2-09~32

HRT16-10

4~6

HJRS1D256

HJX2-09~32

HRT16-16

5.5~8

HJRS1D258

HJX2-09~32

HRT16-20

7~10

HJRS1D2510

HJX2-09~32

HRT16-20

9~13

HJRS1D2513

HJX2-12~32

HRT16-25

12~18

HJRS1D2518

HJX2-18~32

HRT16-35

17~25

HJRS1D2525

HJX2-25~32

HRT16-50

23~32

HJRS1D3632

HJX2-25~32

HRT16-63

30~40

HJRS1D3640

HJX2-32

HRT16-80

23~32

HJRS1D9332

HJX2-40~95

HRT16-63

30~40

HJRS1D9340

HJX2-40~95

HRT16-80

37~50

HJRS1D9350

HJX2-50~95

HRT16-100

48~65

HJRS1D9365

HJX2-50~95

HRT16-100

55~70

HJRS1D9370

HJX2-65~95

HRT16-125

63~80

HJRS1D9380

HJX2-80~95

HRT16-125

80~93

HJRS1D9393

HJX2-95

HRT16-160

Motor
Control&& Protection
Motor Control
Protection

Frame size
rated current(A)

36

93

233

HJRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data

Temperature compensation

-5~+40

Trip class

10A

HJRS1D-25, 36

10

HJRS1D-93

Rated insulation voltage Ui V

660V

Structure characteristics

Protection Function

Overload protection
Phase-failure protection
Manual reset
Automatic reset
Stop button
Test button
Trip direction

Tolerance on slope in any direction

Auxiliary circuit

Utilization category

AC-15

Rated frequency Hz

50

50

50

Rated insulation voltage Ui V

500

500

500

Rated operational voltage Ue V

230

400

230

Rated operational current Ie A

1.64

0.95

0.15

NO

NC

Conventional free air thermal current I


th

Motor Control &


Protection
Motor
Control & Protection

DC-13

234

HJRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Accessories
Thermal Overload Relay

Reference

HJRS1D-25

HJRS1D25J

HJRS1D-36

HJRS1D36J

HJRS1D-93

HJRS1D93J

Trip Characteristic

Sequence

Multiples of
setting current

Trip time
Initial condition

Ambient
temperature

>2h

From cold state

+20

<2h

From hot
state(immediately
following
sequence 1 test)

Trip class
Trip class 10
10A

Limits of operation of relays when energized on all poles


1
Motor
Control&& Protection
Motor Control
Protection

1.05

>2h

1.2

<2h

1.5

2min

4min

From hot
state(immediately
following
sequence 1 test)

7.2

2s
Tp10s

4sTp10s

From cold state

+20

>2h

From cold state

+20

<2h

From hot
state(immediately
following
sequence 1 test)

Limits of operation when energized on two poles


Any two The thirdpoles
pole

235

1.0

1.15

0.9

>2h

<2h

HJRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work Conditions
Ambient temperature: -5~+40, daily average temperature 35
Altitude: 2000m
Humidity:The relative humidity of the installtion position shall not exceed 50% when the maximum
temperature reaches +40. But there can be higher relative humidity under lower temperature.
For example, it can reach 90% when temperature is at 20. Special measures should be taken
against condensation occuring on product surface caused by temperature change
Pollution class: 3

Installation Conditions
Installation Type:
Installation position: Unobvious shake and impact shock is necessary. Vertically
cmounting.
Tolerance on slope in any direction shall not exceed 5

Motor Control &


Protection
Motor
Control & Protection

Wire Connection Picture


FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button

236

HJRS1D Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions
Unit: mm
HJRS1D-25

HJRS1D-36

Motor
Control&& Protection
Motor Control
Protection

HJRS1D-93

237

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

HJRS2 relay provide:


Protect motor and circuit
Possess overload and phase failure protection functions.

Order Information
Reference Description
JRS2
HJRS2

12P5

P16
F:Installed independently
Setting current
Rated current
Model
Current setting(A)

Reference

Recommended
fuse

12.5

0.10~0.16
0.16~0.25
0.25~0.40
0.32~0.5
0.40~0.63
0.63~1.00
0.80~1.25
1.00~1.60
1.25~2.00
1.60~2.50
2.00~3.20
2.50~4.00
3.20~5.00
4.00~6.30
5.00~8.00
6.30~10.0
8.00~12.5
10.0~14.5
0.10~0.16
0.16~0.25
0.25~0.40
0.40~0.63
0.63~1.00
0.80~1.25
1.00~1.60
1.25~2.00
1.60~2.50
2.00~3.20
2.50~4.00
3.20~5.00
4.00~6.30
5.00~8.00
6.30~10.0
8.00~12.5
10.0~16.0
12.5~20.0
16.0~25.

HJRS212P5P16
HJRS212P5P25
HJRS212P5P4
HJRS212P5P5
HJRS212P5P63
HJRS212P51
HJRS212P51P25
HJRS212P51P6
HJRS212P52
HJRS212P52P5
HJRS212P53P2
HJRS212P54
HJRS212P55
HJRS212P56P3
HJRS212P58
HJRS212P510
HJRS212P512P5
HJRS212P514P5
HJRS225P16
HJRS225P25
HJRS225P4
HJRS225P63
HJRS2251
HJRS2251P25
HJRS2251P6
HJRS2252
HJRS2252P5
HJRS2253P2
HJRS2254
HJRS2255
HJRS2256P3
HJRS2258
HJRS22510
HJRS22512P5
HJRS22516
HJRS22520
HJRS22525

HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-6
HRT16-6
HRT16-6
HRT16-6
HRT16-10
HRT16-20
HRT16-20
HRT16-20
HRT16-25
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-6
HRT16-6
HRT16-6
HRT16-6
HRT16-10
HRT16-20
HRT16-20
HRT16-20
HRT16-25
HRT16-32
HRT16-32

25

Motor Control &


Protection
Motor
Control & Protection

Frame size rated


current( A )

238

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Frame size rated


current( A )

Current setting(A)

Reference

Recommended
fuse

32

4.00~6.30
6.30~10.0
10.0~16.0
12.5~20.0
16.0~25.0
20.0~32.0
25.0~36.0
16.0~25.0
20.0~32.0
25.0~36.0
32.0~40.0
36.0~45.0
0.10~0.16
0.16~0.25
0.25~0.40
0.40~0.63
0.63~1.00
0.80~1.25
1.00~1.60
1.25~2.00
1.60~2.5
2.00~3.20
2.50~4.00
3.20~5.00
4.00~6.30
5.00~8.00
6.30~10.0
8.00~12.5
10.0~16.0
12.5~20.0
16.0~25.0
20.0~32.0
25.0~40.0
32.0~45.0
40.0~57.0
50.0~63.0

HJRS2326P3
HJRS23210
HJRS23216
HJRS23220
HJRS23225
HJRS23232
HJRS23236
HJRS24525
HJRS24532
HJRS24536
HJRS24540
HJRS24545
HJRS263P16F
HJRS263P25F
HJRS263P4F
HJRS263P63F
HJRS2631F
HJRS2631P25F
HJRS2631P6F
HJRS2632F
HJRS2632P5F
HJRS2633P2F
HJRS2634F
HJRS2635F
HJRS2636P3F
HJRS2638F
HJRS26310F
HJRS26312P5F
HJRS26316F
HJRS26320F
HJRS26325F
HJRS26332F
HJRS26340F
HJRS26345F
HJRS26357F
HJRS26363F

HRT16-10
HRT16-20
HRT16-25
HRT16-32
HRT16-32
HRT16-50
HRT16-50
HRT16-32
HRT16-50
HRT16-50
HRT16-50
HRT16-63
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-4
HRT16-6
HRT16-6
HRT16-6
HRT16-6
HRT16-10
HRT16-20
HRT16-20
HRT16-20
HRT16-25
HRT16-32
HRT16-32
HRT16-50
HRT16-50
HRT16-63
HRT16-80
HRT16-80

45

63

Motor
Control&& Protection
Motor Control
Protection

239

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Frame size rated


current( A )
80

180

630

Reference

Recommended
fuse

16.0~25.0

HJRS28025

HRT16-32

20.0~32.0

HJRS28032

HRT16-50

25.0~40.0

HJRS28040

HRT16-50

32.0~50.0

HJRS28050

HRT16-63

40.0~57.0

HJRS28057

HRT16-80

50.0~63.0

HJRS28063

HRT16-80

57.0~70.0

HJRS28070

HRT16-100

63.0~80.0

HJRS28080

HRT16-100

70.0~88.0

HJRS28088

HRT16-125

55~88

JRS218088F

HRT16-125

63~90

JRS218090F

HRT16-125

80~110

JRS2180110F

HRT16-200

90~120

JRS2180120F

HRT16-200

110~135

JRS2180135F

HRT16-200

120~150

JRS2180150F

HRT16-200

135~160

JRS2180160F

HRT16-250

150~180

JRS2180180F

HRT16-250

80~125

JRS2400125F

HRT16-200

125~200

JRS2400200F

HRT16-400

160~250

JRS2400250F

HRT16-400

200~320

JRS2400320F

HRT16-500

250~400

JRS2400400F

HRT16-500

320~500

JRS2630500F

HRT16-630

400~630

JRS2630630F

HRT16-630

Motor Control &


Protection
Motor
Control & Protection

400

Current setting(A)

240

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Temperature compensation

-5~+40
HJRS2-12.5,25,32,45,63,80,180

Trip class 10A

HJRS2-400,630

10
Rated insulation voltage Ui V

660V

Structure characteristics
Overload protection

Protection Function

Phase-failure protection
Manual reset
Automatic reset
Stop button
Test button
Trip direction
Tolerance on slope in any direction

Auxiliary circuit

Motor
Control&& Protection
Motor Control
Protection

241

DC-13

Utilization category

AC-15

Rated frequency Hz

50

50

50

Rated insulation voltage Ui V

380

380

500

Rated operational voltage Ue V

220

380

220

Rated operational current Ie A

1.64

0.95

0.16

Conventional free

NO

NC

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Trip Characteristic

Sequence

Multiples of
setting current

Trip time
Initial condition
Trip class Trip
10A
class 10

Ambient
temperature

Limits of operation of relays when energized on all poles


1

1.05

>2h

>2h

From cold state

+20

1.2

<2h

<2h

From hot state(immediately


following sequence 1 test)

1.5

2min

4min

From hot state(immediately


following sequence 1 test)

7.2

2s
Tp10s

4s
Tp10s

From cold state

+20

+20

Limits of operation when energized on two poles


Motor Control &
Protection
Motor
Control & Protection

Any two The thirdpoles


pole

1.0

0.9

>2h

>2h

From cold state

1.15

<2h

<2h

From hot state(immediately


following sequence 1 test)

242

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Work Conditions
Ambient temperature: -5~+40, daily average temperature 35
Altitude: 2000m
Humidity: The relative humidity of the installtion position shall not exceed 50%
when the maximum temperature reaches +40. But there can be higher
relative humidity under lower temperature. For example, it can reach 90% when
temperature is at 20. Special measures should be taken against condensation
occuring on product surface caused by temperature change
Pollution class: 3

Installation Conditions
Installation Type:
Installation position: Unobvious shake and impact shock is necessary. Vertically
mounting. Tolerance on slope in any direction shall not exceed 5

Motor
Control&& Protection
Motor Control
Protection

Wire Connection Picture


FU-Fuse
KM-Contactor
FR-Relay
SB1-Stop Button
SB2-Start Button

243

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions

Unit: mm

Motor Control &


Protection
Motor
Control & Protection

244

HJRS2 Thermal Overload Relay


Standard: IEC 60947-4-1 IEC 60947-5-1

Overall Dimensions

M3.5

35

JRS2-180/F

104max

5
142max
104max

JRS2-400~630/F

Motor
Control&& Protection
Motor Control
Protection

25x4

245

146

171

50

50

10.5

70

HDC9 Capacitor Switching Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Function

HDC9 capacitor switching contactor provide:


Switch three-phase unipolar or multipolar capacitor group,to improve their power factor
Reduce the current closing of the impact of capacitor

Order Information
Auxiliary contact

Rate conventional
thermal current`
25

32

43

95

NC

HDC92511*

HDC92520*

HDC92502*

HDC93211*

HDC93220*

HDC93202*

HDC94311*

HDC94320*

HDC94302*

HDC96312*

HDC96321*

HDC99512*

HDC99521*

Motor Control &


Protection
Motor
Control & Protection

63

Reference

NO

Reference Description
HDC9

10

*
Coil Frequency
Coil Voltage
Auxiliary contact
Rate conventional thermal current
Model

Coil voltage code


coil voltage

36V

110V

127V

220V

380V

400V

Coil frequency code


coil frequency

50Hz
5

60Hz
6

246

HDC9 Capacitor Switching Contactor


Standard: IEC 60947-4-1 IEC 60947-5-1

Technical Data
Model

HDC9-25

HDC9-32

HDC9-43

HDC9-63

HDC9-95

Main circuit
Rated operational voltage

400

Rated insulation voltage

500

Controlled capacitor rate capacity 400V, AC-6b

17

23

29

43

63

Controlled capacitor rate capacity 230V, AC-6b

Kvar

10

15

22.5

400V, AC-6b

Kvar

12

18

20

30

45

25

32

43

63

95

Rate conventional thermal current


Control inrush current capacity

20ln

Mechanical life

104 operations

100

Electric life

400V, AC-6b

10 operations

10

Operating frequency

400V, AC-6b

operations/h

300

Cable connection cross section

400

mm

120

of copper conductor
Coil

Motor
Control&& Protection
Motor Control
Protection

Coil voltage(Us)

AC36,110,127,220,380,400

Operational voltage

85%~110%Us

Drop-out voltage

20%~75%Us

10

Auxiliary contact
Rate conventional thermal current
Minimum load can be connected

6V10mA

Working Conditions
Ambient temperature:-5+40, the daily average temperature 35
2000 m
Humidity: Maximum temperature is +40, air relative humidity of not more than 50%, at a lower temperature allows a higher relative
humidity. For example, 20, when up to 90%, and occasionally due to temperature changes resulting from Gel should take special
measures
Pollution Level: 3
Installation Type:
Installation position: should be installed in the absence of a significant shake and shock and vibration place

Altitude:

Install Location

247

HDZ6 Contactor Relay


Standard: IEC 60947-5-1

Order Information
Product Name

Contact

Coil Voltage

HDZ6

32

32:3NO+NC

B:24V

Default:50HZ

41:4NO+1NC

7:50/60HZ

Coil Power Type

X:440V

Contact Form

Reference

HDZ6 41

HDZ6 32

Code Table of Coil Voltage


24

36

48

110

127

220

380

415

440

50Hz

50/60Hz

B7

E7

F7

M7

Q7

Motor Control &


Protection
Motor
Control & Protection

Coil Voltage (V)

248

HDZ6 Contactor Relay


Standard: IEC 60947-5-1

Main Technical Parameter


Type

HDZ6-41

HDZ6-32

Contact

4NO+1NC

3NO+2NC

AC-15
DC-13

Rated Operational Voltage

AC230V

AC400V

Rated Operational Current

1.6A

0.95A

Rated Operational Voltage

DC125V

DC220V

0.55A

0.27A

Rated Operational Current


Rated Insulation Voltage

690V

Rated Thermal Current

10A

Mechanic Durabilities

10 Million Times
1 Million Times

Electric Durabilities
Control Circuit Voltage
(Us)

50Hz

24V

36V

48V

110V

127V

50/60Hz

24V

48V

110V

220V

380V

Operational Voltage
Range

85%~110% Us

Drop-out Voltage Range

20%~75% Us

Wiring Ability

2.5(X2) m m 2

220V

380V

415V

440V

Motor
Control&& Protection
Motor Control
Protection

Diagram for Accessory Installation

HFC6 Side Auxiliary Contact

HFD6 Top of Auxiliary Contact

HFC6 Side Auxiliary Contact


HFD6 Top of Auxiliary Contact

HFT6 Air Delayed Head

Note: the accessories of HDZ6 are in common use with HDC6,


and please refer to P203 for more information about the accessories.

249

HDZ6 Contactor Relay


Standard: IEC 60947-5-1

Overall Dimension of Installation


Environmental Requirements
Ambient Temperature:-5C~+40C
Altitude: 2000m
Pollution Level: III
No obvious shaking and shock vibration

50/60

35mm Rail

74.5max

4.5

58max

Motor Control &


Protection
Motor
Control & Protection

84max

45.5max

116max
141max

71max

35

Wiring Diagram
HDZ6-41

HDZ6-32

A1 13NO 23NO 33NO 43NO 51NC

A1 13NO 23NO 33NO 43NO 51NC

A2 14NO 24NO 34NO 44NO 52NC

A2 14NO 24NO 34NO 44NO 52NC

250

HDZ8P Miniature Relay

Function

Used to implement the conversion of intermediate control signals and low-power output, In the
eld of industrial control, used in conjunction with contactors, relays, circuit breakers, etc.

Order Information
Rated Current

Poles

LED

Voltage
Type

Reference

5A

AC

HDZ8P052L*1

None

AC

HDZ8P052*1

DC

HDZ8P052L*Z1

None

DC

HDZ8P052*Z1

AC

HDZ8P053L*1

None

AC

HDZ8P053*1

DC

HDZ8P053L*Z1

None

DC

HDZ8P053*Z1

AC

HDZ8P054L*1

None

AC

HDZ8P054*1

DC

HDZ8P054L*Z1

None

DC

HDZ8P054*Z1

AC

HDZ8P034L*1

None

AC

HDZ8P034*1

DC

HDZ8P034L*Z1

None

DC

HDZ8P034*Z1

AC

HDZ8P102L*1

None

AC

HDZ8P102*1

DC

HDZ8P102L*Z1

None

DC

HDZ8P102*Z1

AC

HDZ8P103L*1

None

AC

HDZ8P103*1

DC

HDZ8P103L*Z1

None

DC

HDZ8P103*Z1

AC

HDZ8P104L*1

None

AC

HDZ8P104*1

DC

HDZ8P104L*Z1

None

DC

HDZ8P104*Z1

Motor
Control&& Protection
Motor Control
Protection

3A

10A

251

HDZ8P Miniature Relay

Technical information
5A
2P

3A,5A
3P

Coil voltage
Contact capacity

4P

3P

4P

3-5A/220VAC 30VDC

10A 250VAC/ 28VDC

LED ,No LED

Nominal Coil Power

0.9W/1.2VA

Contact Resistance

100m

0.9W/1.2VA

1.4W/2VA

1.5W/2.5VA

50m

Insulation Resistance

100m
BCC 1500VAC 1minute
BOC 1000VAC 1minute

Operate /Release
Time
Installation method

2P

AC6V-380V ,DC6V-220V
5A/220VAC 30VDC

LED

Dielectric Strength

10A

25ms /25ms
PCB installation, Socket

PCB mounting, Socket

Motor Control &


Protection
Motor
Control & Protection

252

HJSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Function

HJSZ3 Series eletroms time relay provide


Rated AC frequency 50Hz & controlling voltage 400V or below.
Be used as time-control component in the automatic controlling circuit,
according to the scheduled time turn on or off the circuit.

Order Information
Relay mode

Rated working voltage

Relay after

120V

power-on

240V

Motor
Control&& Protection
Motor Control
Protection

400V

253

Relay time

Reference

A: 0.05-0.5s/5s/30s/3M

HJSZ3AA120

B: 0.1-1s/10s/60s/6M

HJSZ3AB120

C: 0.5-5s/50s/5M/30M

HJSZ3AC120

D: 1-10s/100s/10M/60M

HJSZ3AD120

E: 6s-60s/10M/60M/6h

HJSZ3AE120

F: 0.2M-2M/20M/2h/12h

HJSZ3AF120

G: 0.4M-4M/40M/4h/24h

HJSZ3AG120

A: 0.05-0.5s/5s/30s/3M

HJSZ3AA240

B: 0.1-1s/10s/60s/6M

HJSZ3AB240

C: 0.5-5s/50s/5M/30M

HJSZ3AC240

D: 1-10s/100s/10M/60M

HJSZ3AD240

E: 6s-60s/10M/60M/6h

HJSZ3AE240

F: 0.2M-2M/20M/2h/12h

HJSZ3AF240

G: 0.4M-4M/40M/4h/24h

HJSZ3AG240

A: 0.05-0.5s/5s/30s/3M

HJSZ3AA400

B: 0.1-1s/10s/60s/6M

HJSZ3AB400

C: 0.5-5s/50s/5M/30M

HJSZ3AC400

D: 1-10s/100s/10M/60M

HJSZ3AD400

E: 6s-60s/10M/60M/6h

HJSZ3AE400

F: 0.2M-2M/20M/2h/12h

HJSZ3AF400

G: 0.4M-4M/40M/4h/24h

HJSZ3AG400

HJSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Order Information
Relay mode
Relay after

Rated working voltage


120V

power-off

240V

Reference

1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min
1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min
1S: 0.1-1s
2S: 0.2-2s
3S: 0.3s-3s
5S: 0.5s-5s
6S: 0.6s-6s
10S: 1s-10s
20S: 2s-20s
30S: 3s-30s
60S: 6s-60s
100S: 10s-100s
180S: 18s-180s
4M: 0.4min-4min
5M: 0.5min-5min
6M: 0.6min-6min
10M: 1min-10min
20M: 2min-20min
30M: 3min-30min

HJSZ3F1S120
HJSZ3F2S120
HJSZ3F3S120
HJSZ3F5S120
HJSZ3F6S120
HJSZ3F10S120
HJSZ3F20S120
HJSZ3F30S120
HJSZ3F60S120
HJSZ3F100S120
HJSZ3F180S120
HJSZ3F4M120
HJSZ3F5M120
HJSZ3F6M120
HJSZ3F10M120
HJSZ3F20M120
HJSZ3F30M120
HJSZ3F1S240
HJSZ3F2S240
HJSZ3F3S240
HJSZ3F5S240
HJSZ3F6S240
HJSZ3F10S240
HJSZ3F20S240
HJSZ3F30S240
HJSZ3F60S240
HJSZ3F100S240
HJSZ3F180S240
HJSZ3F4M240
HJSZ3F5M240
HJSZ3F6M240
HJSZ3F10M240
HJSZ3F20M240
HJSZ3F30M240
HJSZ3F1S400
HJSZ3F2S400
HJSZ3F3S400
HJSZ3F5S400
HJSZ3F6S400
HJSZ3F10S400
HJSZ3F20S400
HJSZ3F30S400
HJSZ3F60S400
HJSZ3F100S400
HJSZ3F180S400
HJSZ3F4M400
HJSZ3F5M400
HJSZ3F6M400
HJSZ3F10M400
HJSZ3F20M400
HJSZ3F30M400

Motor Control &


Protection
Motor
Control & Protection

400V

Relay time

254

HJSZ3 Series Electronic Time Relay


Standard: IEC 60947-5-1

Technical Data
Condition

AC-15

400V/1.95A; 240V/1.5A; 120V/3.0A

DC-13

250V/0.27A; 125V/0.55A

Repetitive error
Rated themal current
Mechanical life
Electric life
Power loss

5%
5A
6
110 times
5
110 times

Working mode

3W
A: Relay after power-on

F:Relay after power-off

Reset mode

A:Power-off reset

F:External device reset

Contactor endurance

A:5A (Resistive)

F:1AResistive

Relay time

HJSZ3A: 0.05s-0.5s/5s/30s/3M,0.1s-1s/10s/60s/6M

0.5s-5s/50s/5M/30M,1s-10s/100s/10M/60M
6s-60s/10M/60M/6h,0.2M-2M/20M/2h/12h
0.4M-4M/40M/4h/24h
HJSZ3F: 0.1s-1s,0.2s-2s,0.3s-3s,0.5s-5s,0.6s-6s,1s10s,2s-20s,3s-30s,6s-60s,10s-100s,10s-120s,10s180s,0.4M-4M,0.5M-5M,0.6M-6M,1M-10M,2M-20M,3M30M

Motor
Control&& Protection
Motor Control
Protection

Temp.

-5+40

Install mode

Install mounted, Din rail mounted, Panel mounted

Overall Dimensions
Unit: mm

255

HXJ9 Phase Failure And Sequence


Protection Relay
Standard: IEC 60947-5-1

Function

HXJ9 phace failare and sequence proctection relay provide:


Rated AC frequency of 50Hz, rated control supply voltage AC 400V.
Phase failure and phase sequence protector.

Order Information
Function

Voltage

Reference

Phase failure
sequency protection

380V
400V

HXJ9380
HXJ9400

Technical Data
Standard

IEC 60947-5-1

Overvoltage protection

400-480V(adjustable), Reaction time: 1.5-4S(adjustable)

Undervoltage protection

320-400V(adjustabe). Reaction time: 2-9S(adjustable)

Phase failure & phase

Reaction time 2S

Wrong protect time


1 NO,1NC

Contactor endurance

5A Resistive

Power voltage

AC 400V

Mechanical lifetime

6
110 times
5
110 times

Electrical lifetime
Power loss
Contactor capacity

Motor Control &


Protection
Motor
Control & Protection

Contactor mode

1W
AC400V3

Overall Dimensions
Unit: mm

35.5

83Max

91Max
24Max

256

HDTL17 Impulse Relays


Standard: IEC 60947-4

Function

Impulse relays are used for control by pushbuttons of lighting circuits:


Incandescent lamps, low voltage halogen lamps,etc.(resistive loads)
Fluorescent tubes, discharge lamps,etc.(inductive loads)

Order Information
Poles
1P

Rated Current(A)
16

Coil Voltage(V)

Coil Frequency(Hz)

Reference

230

50

HDTL1716N5

Technical data

Motor
Control&& Protection
Motor Control
Protection

257

Rated Voltage

250V

Inrush power

11VA

Impulse duration

50ms

Maximum switching frequency

5 switching operations/minute

Electrical durability

50,000 cycles

Operating temperature

-5C to +40C

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Order Information
Product Name

Frame Current

Setting Current

HDP6

32

P16

32:32A

P16:0.1-0.16A

32:24-32A
P means decimal point

Thermal Release Magnetic Release 400/415V,50/60Hz,AC-3 Recommended

Reference

Current Id

Rated Operating Power

Contactor

0.1-0.16A

1.5A

HDC6-0911

HDP6 32 P16

0.16-0.25A

2.4A

0.06KW

HDC6-0911

HDP6 32 P25

0.25-0.4A

5A

0.09KW

HDC6-0911

HDP6 32 P4

0.4-0.63A

8A

0.12KW

HDC6-0911

HDP6 32 P63

0.63-1A

13A

0.25KW

HDC6-0911

HDP6 32 1

1-1.6A

22.5A

0.37KW

HDC6-0911

HDP6 32 1P6

1.6-2.5A

33.5A

0.75KW

HDC6-0911

HDP6 32 2P5

2.5-4A

51A

1.5KW

HDC6-0911

HDP6 32 4

4-6.3A

78A

2.2KW

HDC6-0911

HDP6 32 6P3

6-10A

138A

4KW

HDC6-0911

HDP6 32 10

9-14A

170A

5.5KW

HDC6-1211

HDP6 32 14

13-18A

223A

7.5KW

HDC6-1811

HDP6 32 18

17-23A

327A

9KW

HDC6-2511

HDP6 32 23

20-25A

327A

11KW

HDC6-2511

HDP6 32 25

24-32A

416A

15KW

HDC6-3211

HDP6 32 32

258

Motor Control &


Protection
Motor
Control & Protection

Setting Current

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Introduction for Functions

Start Button

Adjustable Head

Stop Button

Motor
Control&& Protection
Motor Control
Protection

Tripping Test

1.Start Button

2.Stop Button

ON

Press to start HDP6


After downward pull-out, lock

OFF

Press to stop HDP6

the start button to stop the work

START

3.Adjustable Head

STOP

4.Tripping Test

Can simulate the tripping action,

Set the thermal trip current


TEST

259

STOP

test product performance

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Main Technical Parameter


Operation Mode

Button Operated

Frame Current

32A

Rated Impulse Withstand Voltage

6000V

Rated Operational Voltage

690V

Rated Isolation Voltage

690V

Rated Operational Frequency

50/60Hz

Trip class

10A

Fastening torque

1.7N m

Mechanical Durabilities

100000

Electrical Durabilities AC-3 400V

100000

Overload Protection Category

Phase failure, Thermal Overload

Short circuit protection

Yes

Isolation Function

Yes

Temperature Compensation Function

Yes

Motor Control &


Protection
Motor
Control & Protection

Breaking Capacity
Setting Current

Ue:230/240V

Ue:400/415V

Ue:440V

lcu

lcs

lcu

lcs

lcu

0.1-0.16A

100KA

100KA

100KA

100KA

0.16-0.25A

100KA

100KA

100KA

0.25-0.4A

100KA

100KA

0.4-0.63A

100KA

0.63-1A

lcs

Ue:500V

Ue:690V

lcu

lcs

lcu

lcs

100KA 100KA

100KA

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

100KA

100KA

1-1.6A

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

100KA

100KA

1.6-2.5A

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

3KA

2.5KA

2.5-4A

100KA

100KA

100KA

100KA

100KA 100KA

100KA

100KA

3KA

2.5KA

4-6.3A

100KA

100KA

100KA

100KA

50KA

50KA

50KA

100KA

3KA

2.5KA

6-10A

100KA

100KA

100KA

100KA

15KA

15KA

10KA

50KA

3KA

2.5KA

9-14A

100KA

100KA

15KA

7.5KA

8KA

4KA

6KA

10KA

3KA

2.5KA

13-18A

100KA

100KA

15KA

7.5KA

8KA

4KA

6KA

4.5KA

3KA

2.5KA

17-23A

50KA

50KA

15KA

6KA

6KA

3KA

4KA

4.5KA

3KA

2.5KA

20-25A

50KA

50KA

15KA

6KA

6KA

3KA

4KA

3KA

3KA

2.5KA

24-32A

50KA

50KA

10KA

5KA

6KA

3KA

4KA

3KA

3KA

2.5KA

Remark: Icu Rated Ultimate Short-circuit Breaking Capacity


Ics Rated Service Short-circuit Breaking Capacity

260

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Main Technical Parameter

Fuse Select gL/Gg ( When the prospective short-circuit current is greater than
the rated ultimate short-circuit breaking capacity Icu, need a spare fuse)
Setting Current

Ue:230/240V

Ue:400/415V

Ue:690

0.1-0.16A

0.16-0.25A

0.25-0.4A

0.4-0.63A

0.63-1A

Motor
Control&& Protection
Motor Control
Protection

1-1.6A

1.6-2.5A

20

2.5-4A

32

4-6.3A

40

6-10A

40

9-14A

80

50

13-18A

80

50

17-23A

100

100

50

20-25A

100

100

50

24-32A

100

100

50

*) "-"No need to use Fuse

3 Phase Motor Rated Power,50/60Hz,AC-3

261

Setting Current

Ue:230/240V

Ue:400/415V

Ue:690

0.1-0.16A

0.16-0.25A

0.06kw

0.25-0.4A

0.09kw

0.4-0.63A

0.12kw

0.37kw

0.63-1A

0.25kw

0.55kw

1-1.6A

0.37kw

1.1kw

1.6-2.5A

0.37kw

0.75kw

1.5kw

2.5-4A

0.75kw

1.5kw

3kw

4-6.3A

1.1kw

2.2kw

4kw

6-10A

2.2kw

4kw

7.5kw

9-14A

3kw

5.5kw

9kw

13-18A

4kw

7.5kw

11kw

17-23A

5.5kw

9kw

15kw

20-25A

5.5kw

11kw

18.5kw

24-32A

7.5kw

15kw

22kw

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Operating Characteristics
No.

Multiple of Setting Current

Operating Time

Starting Conditions

Environmental Temperature

Operating Characteristics for Load Balance of the Phases


1

1.05

Without operation within 2h

Cold State

+20 C

1.2

Operation within 2h

Hot State (After No.1 Test)

+20 C

1.5

Operation within 2min

Hot State (After No.1 Test)

+20 C

7.2

Operation at 2s<Tp 10s

Cold State

+20 C

Operating Characteristics for Phase Load Unbalance (Phase Failure)


rd

Any 2-Phase

3 Phase

1.0

0.9

Without operation within 2h

Cold State

+20 C

1.15

Operation within 2h

Hot State (After No.1 Test)

+20 C

The temperature compensation performance


1

1.0

Without operation within 2h

Cold State

+40 C

1.2

Operation within 2h

Hot State (After No.1 Test)

+40 C

1.05

Without operation within 2h

Cold State

-5 C

1.3

Operation within 2h

Hot State (After No.3 Test)

-5 C

Average (Environmental Temperature 20C )

Motor Control &


Protection
Motor
Control & Protection

(Minute)

3 phase cold characteristic

Action Time

2 phase cold characteristic

(Second)
3 phase hot characteristic

Multiple of Setting Current

Wiring Diagram

HDP6 drive motor directly


1

HDP6 use with HDC6


1

I> I> I>

I> I> I>

A1

A2

KM

Used for low operation frequency area

M
~

Used for high operation frequency area

262

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Accessories
Name

Type

Spec.

Reference

Undervoltage Release

HAU

110~127V

HAU110

220~240V

HAU220

380~400V

HAU380

415V

HAU415

110~127V

HAS110

220~240V

HAS220

380~400V

HAS380

415V

HAS415

2NO

HAE20

1NC+1NO

HAE11

2NO

HAN20

1NC+1NO

HAN11

IP55

HDP632MC

Shunt Release

Auxiliary Contact

HAS

Top

HAE

Motor
Control&& Protection
Motor Control
Protection

Side

HAN

Waterproof Cover

Installation of HAE11 or HAE20

HDP6-32MC

Parameters of instantaneous auxiliary contact


Name

Rated Isolation Applicable


Voltage UI
Cat.

Rated Operational Rated Operational Conventional


Voltage
Current
Heating Current

Top Auxiliary
Contact

250V

24V

2A

2.5A

48V

1.25A

2.5A

110V

1A

2.5A

230V

0.5A

2.5A

24V

1A

2.5A

48V

0.3A

2.5A

48V

6A

6A

110V

4.5A

6A

230V

3.3A

6A

380V

2.2A

6A

24V

6A

6A

48V

5A

6A

220V

0.5A

6A

AC-15

DC-13

Side Auxiliary
690V
Contact

1. Pry the top auxiliary protective cover up;


2. Put the at surface of the top auxiliary
contact close to the circuit breaker;
3. Align the installation position and insert it.

263

AC-15

DC-13

HDP6 Motor Circuit Breaker


Standard: IEC 60947-1,
IEC 60947-2,
IEC 60947-4-1

Accessories Installation

Name

Installation Position

The largest installed Qty.

Top Auxiliary Contact

Face-up

HAN

Side Auxiliary Contact

Left Side

HAU

Undervoltage Release

Right Side

HAS

Shunt Release

Right Side

Motor Control &


Protection
Motor
Control & Protection

Type
HAE

Overall Dimension for Installation

264

HDS2 Magnetic Starter


Standard: IEC 60947-4

Order information
Name of Product

Frame size
rated current

HDS2

13
13: 13A
25: 25A
95: 95A

Control
Method

Setting Current

B
B: With button

1P6
1P6:1-1.6A

93:80-93 A

Remark: P means decimal point

Motor
Control&& Protection
Motor Control
Protection

Frame size rated


current (A)

Setting
Current (A)

Order No.
With Button

13

1-1.6
1.6-2.5
2.5-4
4-6
5.5-8
7-10
9-13
12-18
17-25
23-32
30-40
37-50
48-65
63-80
80-93

HDS213B1P6
HDS213B2P5
HDS213B04
HDS213B06
HDS213B08
HDS213B10
HDS213B13
HDS225B18
HDS225B25
HDS295B32
HDS295B40
HDS295B50
HDS295B65
HDS295B80
HDS295B93

25
95

Note: means coil voltage code.

Code Table of Coil Voltage


Coil Voltage (V)

36

110

127

50Hz
50/60Hz

220

230

380

400

M7

N7

Q7

V7

Applicable Scope
HDS2 Series of Magnetic Starter (hereinafter referred to as Starter) is mainly used for control AC
50Hz (or 50/60Hz) and maximum rated working voltage up to 660V, as well as direct start and stop
of three-phase squirrel cage induction motor with maximum rated working current up to 93A under
using type of AC-3, and providing overloading protection against the motor.

265

HDS2 Magnetic Starter


Standard: IEC 60947-4

Technical parameter

Type

HDS2-13

HDS2-25
HDS2-95

Controllable Max
Setting
Current (A) Power of Motor
(KW) 380V
0.37
0.75
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45

AC
Contactor
Type

Thermal
Overload
Relay Type

HJX2-09
HJX2-09
HJX2-09
HJX2-09
HJX2-09
HJX2-09
HJX2-18
HJX2-25
HJX2-25
HJX2-40
HJX2-40
HJX2-50
HJX2-65
HJX2-80
HJX2-95

HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-25
HJRS1D-93
HJRS1D-93
HJRS1D-93
HJRS1D-93
HJRS1D-93
HJRS1D-93

Motor Control &


Protection
Motor
Control & Protection

1-1.6
1.6-2.5
2.5-4
4-6
5.5-8
7-10
9-13
12-18
17-25
23-32
30-40
37-50
48-65
63-80
80-93

Option Type

Overall Dimension of Installation (mm)

HDS2-13

HDS2-25

HDS2-95

266

HLMK Series Current Transformer


Standard: IEC 60044-1

Function

HLMK Series Current Transformer provide:


Measuring and transforming the high current to low current.

Order Information

Model

Current ratio Rated Load Bar


(VA)
(mm)
(A)

HLMK-0.66-30

30/5
50/5
75/5
100/5
100/5
150/5
200/5
250/5
300/5
250/5
300/5
400/5
500/5
300/5
400/5
500/5
600/5
750/5
800/5
1000/5
500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5

HLMK-0.66-40

HLMK-0.66-50
Motor Control &
Protection

HLMK-0.66-60

Power
Energy
Management
Power
Energy
Management

HLMK-0.66-80

HLMK-0.66-100

HLMK-0.66-120

267

Class: 0.5
Maximum Voltage: 0.66KV

5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75

3010
3010
3010
4010
4010
4010
4010
5010
5010
5010
5010
5010
5010
5010
6020
6020
6020
6020
6020
6020
6020
8010 or 6030
8010 or 6030
8010 or 6030
8010 or 6030
8010 or 6030
8010 or 6030
8010 or 6030
8010 or 6030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
10010 or 8030
12010 or 8030
12010 or 8030
12010 or 8030
12010 or 8030
12010 or 8030
12010 or 8030

Diameter Number of Turns Reference


through the core
(mm)
20
20
20
20
20
20
20
20
20
30
30
30
30
35
35
35
35
35
35
35
45
45
45
45
45
45
45
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

5
3
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

HLMKP63030
HLMKP65030
HLMKP67530
HLMKP610030Z
HLMKP610030
HLMKP615030
HLMKP620030
HLMKP625030
HLMKP630030
HLMKP625040
HLMKP630040
HLMKP640040
HLMKP650040
HLMKP630050
HLMKP640050
HLMKP650050
HLMKP660050
HLMKP675050
HLMKP680050
HLMKP6100050
HLMKP650060
HLMKP660060
HLMKP675060
HLMKP680060
HLMKP6100060
HLMKP6120060
HLMKP6150060
HLMKP660080
HLMKP675080
HLMKP680080
HLMKP6100080
HLMKP6120080
HLMKP6150080
HLMKP6200080
HLMKP6250080
HLMKP6600100
HLMKP6750100
HLMKP6800100
HLMKP61000100
HLMKP61200100
HLMKP61500100
HLMKP62000100
HLMKP62500100
HLMKP63000100
HLMKP61500120
HLMKP62000120
HLMKP62500120
HLMKP63000120
HLMKP64000120
HLMKP65000120

HLMK Series Current Transformer


Standard: IEC 60044-1

Order Information

Class: 1
Maximum Voltage: 0.66KV

Current ratio Rated Load


(VA)
(A)

HLMK-0.66-30

30/5
50/5
75/5
100/5
150/5
200/5
250/5
300/5
250/5
300/5
400/5
500/5
600/5
300/5
400/5
500/5
600/5
750/5
800/5
1000/5
1200/5
500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
600/5
750/5
800/5
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5

HLMK-0.66-40

HLMK-0.66-50

HLMK-0.66-60

HLMK-0.66-80

HLMK-0.66-100

HLMK-0.66-120

5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
5-3.75
10-3.75
5-3.75
5-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
5-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
10-3.75
10-3.75
10-3.75
10-3.75
10-3.75
15-3.75
15-3.75
20-3.75
20-3.75
15-3.75
15-3.75
20-3.75
20-3.75
25-3.75
25-3.75

Bar
(mm)

Diameter Number of Turns Reference


through the core
(mm)

20
20
20
20
20
20
3010
20
3010
20
3010
30
4010
30
4010
30
4010
30
4010
30
4010
35
5010
35
5010
35
5010
35
5010
35
5010
35
5010
35
5010
35
6020
45
6020
45
6020
45
6020
45
6020
45
6020
45
6020
45
6020
45
6020
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
8010 or 6030 50
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
10010 or 8030 60
12010 or 8030 60
12010 or 8030 60
12010 or 8030 60
12010 or 8030 60
12010 or 8030 60
12010 or 8030 60

5
3
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

HLMKP6P13030
HLMKP6P15030
HLMKP6P17530
HLMKP6P110030
HLMKP6P115030
HLMKP6P120030
HLMKP6P125030
HLMKP6P130030
HLMKP6P125040
HLMKP6P130040
HLMKP6P140040
HLMKP6P150040
HLMKP6P160040
HLMKP6P130050
HLMKP6P140050
HLMKP6P150050
HLMKP6P160050
HLMKP6P175050
HLMKP6P180050
HLMKP6P1100050
HLMKP6P1120050
HLMKP6P150060
HLMKP6P160060
HLMKP6P175060
HLMKP6P180060
HLMKP6P1100060
HLMKP6P1120060
HLMKP6P1150060
HLMKP6P1200060
HLMKP6P160080
HLMKP6P175080
HLMKP6P180080
HLMKP6P1100080
HLMKP6P1120080
HLMKP6P1150080
HLMKP6P1200080
HLMKP6P1250080
HLMKP6P1600100
HLMKP6P1750100
HLMKP6P1800100
HLMKP6P11000100
HLMKP6P11200100
HLMKP6P11500100
HLMKP6P12000100
HLMKP6P12500100
HLMKP6P13000100
HLMKP6P11500120
HLMKP6P12000120
HLMKP6P12500120
HLMKP6P13000120
HLMKP6P14000120
HLMKP6P15000120

268

Power Energy Management

Model

HLMK Series Current Transformer


Standard: IEC 60044-1

Technical
Data

Primary current: 100A-5000A


Secondary approval: 5A, 1A
Maximum voltage: 0.66kV
Class: 0.5, 1.0, 3.0
Short time thermal current: Ith=100Ih
Rated security coefficient: FS<5
Standard: IEC 60044-1

Overall Dimensions
Unit: mm

Motor Control &


Protection
Power
Energy
Management
Power
Energy
Management

269

Model

HLMK-0.66-30

79

60

37

HLMK-0.66-40

99

75

40

HLMK-0.66-50

99

82

40

HLMK-0.66-60

126

102

40

HLMK-0.66-80

118

125

40

HLMK-0.66-100

136

170

40

HLMK-0.66-120

136

190

41

Meter Overview
Watt-hour Meter
Meter

Single-phase

DDS607

271

Type:
Single-phase
Specification
1.5(6)A, 3(6)A
2.5(10)A, 5(20)A
5(30)A, 10(40)A
15(60)A, 20(80)A
30(100)A

Three-phase
DTS607

273

DSS607
Type:
Three-phase
Three-wire

Specification

Specification

1.5(6)A, 3(6)A
2.5(10)A, 5(20)A
5(30)A, 10(40)A
15(60)A, 20(80)A
30(100)A

1.5(6)A, 3(6)A
5(20)A, 10(40)A
15(60)A. 20(80)A
30(100)A

Power Energy Management

Type:
Three-phase
Four-wire

276

Panel Meter

72 Series
Type:
Ammeter
Voltmeter
Frequency meter
Specification
72x72mm

279

96 Series

281

Type:
Ammeter
Voltmeter
Frequency meter
Specification
96x96mm

270

HDDS607 Single-phase Electronic


Watt-hour Meter
Standard:IEC 620531-21

Function

HDDS607 single-phase watt-hour meter provide:


Measuring the active energy in the single-phase AC power network with
frequency of 50Hz or 60Hz.
Measuring the active energy for enterprises, transformer substation or power substation.
And be used as the automation meter in power transmission and distribution network.

Order Informationn

Motor Control &


Protection
Power
Energy
Management
Power
Energy
Management

Function Description

Current
Reference
specification

Type A (Import chip)

1.5(6)A

HDDS607N16M4A

Type A (Import chip)

2.5(10)A

HDDS607N110M4A

Type A (Import chip)

5(20)A

HDDS607N120M4A

Type A (Import chip)

5(30)A

HDDS607N130M6A

Type A (Import chip)

10(40)A

HDDS607N140M4A

Type A (Import chip)

15(60)A

HDDS607N160M4A

Type A (Import chip)

20(80)A

HDDS607N180M4A

Type A (Import chip)

30(100)A

HDDS607N1100M3A

Type C (Domestic chip)

1.5(6)A

HDDS607N26M4C

Type C (Domestic chip)

2.5(10)A

HDDS607N210M4C

Type C (Domestic chip)

5(20)A

HDDS607N220M4C

Type C (Domestic chip)

5(30)A

HDDS607N230M6C

Type C (Domestic chip)

10(40)A

HDDS607N240M4C

Type C (Domestic chip)

15(60)A

HDDS607N260M4C

Type C (Domestic chip)

20(80)A

HDDS607N280M4C

Type C (Domestic chip)

30(100)A

HDDS607N2100M3C

LCD without 485 communications

1.5(6)A

HDDS607N16M4CD

LCD without 485 communications

2.5(10)A

HDDS607N110M4CD

LCD without 485 communications

5(20)A

HDDS607N120M4CD

LCD without 485 communications

5(30)A

HDDS607N130M6CD

LCD without 485 communications

10(40)A

HDDS607N140M4CD

LCD without 485 communications

15(60)A

HDDS607N160M4CD

LCD without 485 communications

20(80)A

HDDS607N180M4CD

LCD with 485 communications

1.5(6)A

HDDS607N16M4CD485

LCD with 485 communications

5(20)A

HDDS607N120M4CD485

LCD with 485 communications

10(40)A

HDDS607N140M4CD485

LCD with 485 communications

15(60)A

HDDS607N160M4CD485

LCD with 485 communications and infrared communications

1.5(6)A

HDDS607N116M4CD485I

LCD with 485 communications and infrared communications

2.5(10)A

HDDS607N110M4CD485I

LCD with 485 communications and infrared communications

5(20)A

HDDS607N120M4CD485I

LCD with 485 communications and infrared communications

5(30)A

HDDS607N130M6CD485I

LCD with 485 communications and infrared communications

10(40)A

HDDS607N140M4CD485I

LCD with 485 communications and infrared communications

15(60)A

HDDS607N160M4CD485I

LCD with 485 communications and infrared communications

20(80)A

HDDS607N180M4CD485I

LCD with 485 communications and infrared communications

30(100)A

HDDS607N1100M3CD485I

Note: Users need special specifications can be customized

271

HDDS607 Single-phase Electronic


Watt-hour Meter
Standard:IEC 620531-21

Technical Data
Standard

IEC 620531-21

Certificate

KEMA

Working voltage(V)

230V

Power loss

Voltage circuit 2W per10VA, Current circuit 4VA

Optional functions

LCD display, Infrared communication, 485 communication

Normal working temp.

-10~+45

Limited working temp.

-25~+55

Normal working voltage 0.9~1.1(Ref. voltage)


Limited working voltage 0.8~1.15(Ref. voltage)
Relative humidity

75%

Installation location

Should be installed in the height of 1.8m vertically and the angularity1

Overall Dimensions
Unit: mm

Power Energy Management

Single-phase Type A,C Meter

Single-phase LCD Meter

272

HDTS607 Three-phase Four-wire


Electronic Watt-hour Meter
Standard: IEC 62053-21

Function

HDTS607 Three Phase four-wire watt-hour meter provide:


Measuring the active energy in the three-phase four-wire AC power network at
frequency of 50Hz or 60Hz.
Measure the active energy of enterprises, transformer substation or power
stations, and be used as automation meters of power transmission and
distribution network.

Order Information
Voltage(V)

Grade

Current(A)

Reference

57.7/100

1.5(6)

HDTS607WY16M4

3(6)

HDTS607WY16M2

1.5(6)

HDTS607NV16M4

2.5(10)

HDTS607NV110M4

3(6)

HDTS607NV16M2

5(20)

HDTS607NV120M4

10(40)

HDTS607NV140M4

15(60)

HDTS607NV160M4

20(80)

HDTS607NV180M4

30(100)

HDTS607NV1100M3

230/400

Motor Control &


Protection

NOTE: M expresses the current multiple in the standard codes.


Transformer function (H) is merely available for 1.5(6)A and 3(6)A.

Power
Energy
Management
Power
Energy
Management

273

HDTS607 Three-phase Four-wire


Electronic Watt-hour Meter
Standard: IEC 62053-21

Technical Data
Working voltage

57.7/100V, 230/400V

Power loss

Voltage circuit2W per10VA, Current circuit4VA

Optional functions

LCD display, Infrared communication, 485 communication

Normal working temp.

-10+45

Ultimate working temp.

-25+55

Normal working voltage

0.91.1(Ref. voltage)

Ultimate working voltage 0.81.15(Ref. voltage)


Relative humidity

75

Installation location

Should be installed in the height of 1.8m vertically and the


angularity1.

Wiring Diagram

Wiring diagram for 3 x 57.7/100V 3 x 3(6)A with voltage transformer

Wiring diagram for 3 x 230/400V 3 x 3(6)A with current transformer

Power Energy Management

274

HDTS607 Three-phase Four-wire


Electronic Watt-hour Meter
Standard: IEC 62053-21

Wiring Diagram

Wiring diagram for 3 x 230/400V 3 x 2.5(10)A direct

pulse

Motor Control &


Protection

pulse

pulse

Wiring diagram for impulse testing

Overall Dimensions

Power
Energy
Management
Power
Energy
Management

275

pulse

Unit: mm

HDSS607 Three-phase Three-wire Electronic


Watt-hour Meter
Standard: IEC 62053-21

Function

HDSS607 Single-phase electronic watt-hour meter provides:


Measuring the active energy in the three-phase three-wire AC power network at
frequency of 50Hz or 60Hz.
Measure the active energy of enterprises, transformer substation or power stations,
and be used as automation meters of power transmission and distribution network

Order Information

Voltage(V)

Grade

Current(A)

Reference

100

1.56

HDSS607Y16M4

36

HDSS607Y16M2

1.56

HDSS607V16M4

36

HDSS607V16M2

520

HDSS607V120M4

1040

HDSS607V140M4

400

1560

HDSS607V160M4

2080

HDSS607V180M4

30100

HDSS607V1100M3

NOTE: M expresses the current multiple in the standard codes.


Transformer function (H) is merely available for 1.5(6)A and 3(6)A.

Power Energy Management

276

HDSS607 Three-phase Three-wire Electronic


Watt-hour Meter
Standard: IEC 62053-21

Technical Data
Standard

IEC 62053-21

75%

Wiring Diagram

Motor Control &


Protection
Power
Energy
Management
Power
Energy
Management

277

Wiring diagram for 3 x 100V 3 x 3(6)A with voltage transformer

Wiring diagram for 3 x 400V 3 x 3(6)A with current transformer

HDSS607 Three-phase Three-wire Electronic


Watt-hour Meter
Standard: IEC 62053-21

Wiring Diagram

Wiring diagram for 3 x 400V 3 x 2.5(10)A direct

pulse

pulse

pulse

pulse

Wiring diagram for impulse testing

Overall Dimensions
Unit: mm
Power Energy Management

278

H72 Series Panel Meter


Standard: IEC 60051

Function

H72 series panel meter provide:


H72T applies to measure the current, voltage or frequency in the AC circuit.
H72C applies to measure the current or voltage in the DC circuit.
Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power
supply cabinet, control cabinet and other electric-control facilities in the AC transmission circuit
system

Order Information
Accuracy Specification
rating

Note

Shape(mm)

Reference

Ammeter

1.5

30/5A

AC Type

727267.5

H72TA30

40/5A

External connection 727267.5

H72TA40

50/5A

transformer

727267.5

H72TA50

60/5A

2 times of current

727267.5

H72TA60

75/5A

overload

727267.5

H72TA75

80/5A

727267.5

H72TA80

100/5A

727267.5

H72TA100

150/5A

727267.5

H72TA150

160/5A

727267.5

H72TA160

200/5A

727267.5

H72TA200

250/5A

727267.5

H72TA250

300/5A

727267.5

H72TA300

400/5A

727267.5

H72TA400

600/5A

727267.5

H72TA600

800/5A

727267.5

H72TA800

1000/5A

727267.5

H72TA1000

1600/5A

727267.5

H72TA1600

5000/5A

727267.5

H72TA5000

10000/5A

727267.5

H72TA10000

727267.5

H72TA5A

Motor Control &


Protection

Type

Power
Energy
Management
Power
Energy
Management

2.5

Voltmeter

5A

AC Type

Direct connection

15A

AC Type

727267.5

H72TA15A

20A

Direct connection

727267.5

H72TA20A

25A

2 times of current

727267.5

H72TA25A

30A

overload

727267.5

H72TA30A

40A

727267.5

H72TA40A

50A

727267.5

H72TA50A

60A

727267.5

H72TA60A

80A

727267.5

H72TA80A

100A

727267.5

H72TA100A

727267.5

H72CA5A

727267.5

H72TV300V

500V

727267.5

H72TV500V

600V

727267.5

H72TV600V

DC Type

727267.5

H72CV5500V

45-55HZ (200V) AC Type

727267.5

H72THZ01200V

1.5

5A

DC Type

1.5

300V

AC Type

500V
Frequency meter

279

1.0

H72 Series Panel Meter


Standard: IEC 60051

Technical Data
Standard

IEC 60051

Dielectric strength test

Frequency 50Hz
/60Hz
Voltage 2000V, duration 1 minute
2

Impact test
Response time

Max acceleration 147m/s

Angular Deflection

90

Temp.
Humidity

-25~+40
(25%~80%)RH
No mildew, insects, salt mist, dew in the air,
few sands and dusts are permitted.
Shall be installed Vertically
v

Environment
:
Installation:

4s

Overall Dimensions

Power Energy Management

280

H96 Series Panel Meter


Standard: IEC 60051

Function

H96 series panel meter provide:


H96T applies to measure the current, voltage or frequency in the AC circuit.
H96C applies to measure the current or voltage in the DC circuit.
Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power
supply cabinet, control cabinet and other electric-control facilities in the AC transmission
circuit system

Order Information
Type
Ammeter

Accuracy Specification
rating
1.5

Motor Control &


Protection
Power
Energy
Management
Power
Energy
Management

2.5

1.5
Voltmeter

1.5

Note

Shape(mm)

Reference

30/5A

AC Type

969667.5

H96TA30

40/5A

External connection 969667.5

H96TA40

50/5A

transformer

969667.5

H96TA50

60/5A

969667.5

H96TA60

75/5A

969667.5

H96TA75

80/5A

969667.5

H96TA80

100/5A

969667.5

H96TA100

150/5A

969667.5

H96TA150

160/5A

969667.5

H96TA160

200/5A

969667.5

H96TA200

250/5A

969667.5

H96TA250

300/5A

969667.5

H96TA300

400/5A

969667.5

H96TA400

600/5A

969667.5

H96TA600

800/5A

969667.5

H96TA800

1000/5A

969667.5

H96TA1000

1600/5A

969667.5

H96TA1600

5000/5A

969667.5

H96TA5000

10000/5A

969667.5

H96TA10000

969667.5

H96TA5A

5A

AC Type

Direct connection

15A

AC Type

969667.5

H96TA15A

20A

Direct connection

969667.5

H96TA20A

25A

969667.5

H96TA25A

30A

969667.5

H96TA30A

40A

969667.5

H96TA40A

50A

969667.5

H96TA50A

60A

969667.5

H96TA60A

80A

969667.5

H96TA80A

100A

969667.5

H96TA100A

DC Type

969667.5

H96CA5A

AC Type

969667.5

H96TV300V

500V

969667.5

H96TV500V

600V

969667.5

H96TV600V

DC Type

969667.5

H96CV500

45-55HZ (200V) AC Type

969667.5

H96THZ01200V

5A
300V

500V
Frequency meter

1.0

281

H96 Series Panel Meter


Standard: IEC 60051

Technical Data
Standard

IEC 60051

Dielectric strength test

Frequency 50Hz
/60Hz
Voltage 2000V, duration 1 minute
2

Impact test

Max acceleration 147m/s

Response time

4s

Angular Deflection

90

Temp.
Humidity:

-25~+40
(25%~80%)RH
No mildew, insects, salt mist, dew in the air,
few sands and dusts are permitted.
v
Shall be installed Vertically

Environment

Installation:

Overall Dimensions

Power Energy Management

282

Time Switch Overview

HKG316T

284

Max.switch times
per day:10-on-10-off,
8-on-8-off
Reset:Power-off reset

HKG316TD
Max.switch times
per day:16-on-16-off

285

Reset:key-button reset
Motor Control &
Protection
Power
Energy
Management
Power
Energy
Management

HKG816A
Max.switch times
per day:16-on-16-off

286

Reset:key-button reset

HKG816B
Max.switch times
per day:8-on-8-off
Reset:key-button reset

283

286

HKG316T Series Digital Time Switch


Standard: IEC 60947-5-1

HKG316T Series Digital Time Switch provide:


Rated AC frequency of 50Hz, rated AC control voltage 400V or below.
Be used as time control components in automatic control circuit, according to the
scheduled time to turn-on or off the circuits.

Order Information
Output loops

Rated control voltage

Reference

10-on-10-off (Single output)

AC:230V

HKG316T230

AC:400V

HKG316T400

AC:230V

HKG316T2230

AC:400V

HKG316T2400

8-on-8-off (Double output)

Technical Data
IEC 60947-5-1

Control time

Control power

Setting Value range from 1min to168h


Operation by daily or weekly
AC-15: 240V/3A 400V/1.9A
6kW

Rated control voltage

230/400V AC

Rated thermal cur.


Accuracy
Mechanical life

10A
y
2
1106 times

Electrical life

1105 times

Power loss

3W

Temp.
Display modet

-5+40
~
Digital LED display

Time-set Mode

Digital Keyswitch settingt

Battery

Inner alkaline battery

Install Mode

Install mounted, Din rail mounted

Using mode

Power Energy Management

Standard

Overall Dimensions
Unit: mm

Wiring Diagram

OUT
PUT

LOAD

Single output

IN L1

OUT L1 OUT L2

SOURCE

INPUT

SOURCE

Function

LOAD 1

LOAD 2

Double output

284

HKG316TD Series Digital Time Switch


Standard: IEC 60947-5-1

Function

HKG316TD Series Digital Time Switch provide:


Rated AC frequency of 50Hz, rated control supply voltage AC 400V or below.
Any circuit equipments that need to be turned-on-or-off timely.

Order Information
Output loops

Rated control voltage

Reference

16-on-16-off

AC:230V

KG316TD230

AC:400V

KG316TD400

Technical Data
Standard

IEC 60947-5-1

Control time

Control power

Setting Value range from 1min to168h


Operation by daily or weekly
AC-15: 240V/3A 400V/1.9A
6kW

Rated control voltage

230/400V AC

Rated thermal cu r.
Accuracy
Mechanical life

10A

Electrical life

1105 times

Power loss

3W

Temp.
Display modet

-5+40
Digital LED display

Time-set Mode

Digital Keyswitch settingt

Battery

Inner rechangeable battery

Install Mode

Install mounted, Din rail mounted

Using mode

Motor Control &


Protection

1106 times

Power
Energy
Management
Power
Energy
Management

Overall Dimensions
Unit: mm
Management
Power Energy

Wiring Diagram

285

HKG816 Series Digital Times Switch


Standard: IEC 60947-5-1

Function

KG816 Series Digital Time Switch provide:


Rated AC frequency of 50Hz, rated AC control voltage 230V or below.
Be used as time control components in automatic control circuit, according to
the scheduled time to turn-on or off the circuits.

Order Information
Cover

Output loops

Rated control voltage

Reference

Non-transparent cover

16-on-16-off

AC:230
C:230V

HKG816B230

Transparent cover

8-on-8-off

AC:230V

HKG816A230

HKG816A

Technical Data
Standard

IEC 60947-5-1

Control time

Setting value range from 1min to 168 hrs


Operate by daily or weekly

HKG816B

Using mode

AC-15: 240V/3A; 400V/1.9A


6kW
230VAC

Rated thermal cur.

10A

Accuracy

2s/day

Mechanical life

1X106

Electrical life

1X105

Power loss

4.5W

Temp.

-5~+40

Display mode

Digital LED display

Time-set Mode

Digital Keyswitch setting

Battery

Inner rechangable battery

Install Mode

Din rail mounted

Power Energy Management

Countrol power
Rated control voltage

Overall Dimensions
Unit: mm

87

36

45.5

87

66

286

Voltage Stabilizer Overview

Single-phase

HTND

288

Type: Single-phase
Specification: 0.5kVA, 1kVA
1.5kVA, 2kVA, 3kVA, 5kVA,
7kVA, 10kVA, 15kVA, 20kVA, 30kVA

Three-phase

HSJW
Type: Three-phase

290

Motor Control &


Protection

Specification: 1.5kVA, 3kVA


4.5kVA, 6kVA, 9kVA, 15kVA,
20kVA, 30kVA, 45kVA, 60kVA

Power
Energy
Management
Power
Energy
Management

HSBW

292

Type: Three-phase Compensation


Specification: 10kVA, 15kVA
30kVA, 50kVA, 100kVA, 150kVA,
200kVA, 250kVA, 300kVA, 400kVA,
500kVA, 600kVA, 800kVA

287

HTND Single-phase Full Automatic


AC Voltage Stabilizer
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1

Function

TND single-phase AC voltage stabilizer provide:


This product is constructed by connecting three stabilizers with Y-connection
Wide input voltage range, high efficiency, over-load protection, short adjusting time,
high regulation accuracy, same input and output voltage waveform, small volume,
less weight.
It's available in the electric equipments and facilities in housing, school, shop, office
and precision instrument for scientific experiment.

Order Information
Shape

Desktop

Cabinet

Desktop

Output
voltage

Power
rating

220V

0.5K

TNDP5HE220

TNDP5HB220

1K

TND1HE220

TND1HB220

1.5K

TND1P5HE220

TND1P5HB220

220V

230V

Reference
Europe plug

TND2H220

3K

TND3H220

5K

TND5H220

7K

TND7H220

10K
10K

TND10H220
TND10GH220

15K

TND15GH220

20K

TND20GH220

30K

TND30GH220

0.5K

TNDP5HE230

TNDP5HB230

1K

TND1HE230

TND1HB230

TND1P5HB230

TND1P5HE230

Power Energy Management

230V

Terminal connect

2K

1.5K

Cabinet

British plug

2K

TND2H230

3K

TND3H230

5K

TND5H230

7K

HTND7H230

10K

TND10H230

10K

TND10GH230

15K

TND15GH230

20K

TND20GH230

30K

TND30GH230

288

HTND Single-phase Full Automatic


AC Voltage Stabilizer
Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1

Technical Data
HTND0.5kVA~5kVA
Type
Voltage regulation accuracy 2204%,1104%

Output voltage Undervoltage protection
Overvoltage protection

HTND7kVA~30kVA
2204%

184V4V(set up according to the customers request)


246V4V

single-phase
Phase
Input voltage range

160V~240V

Efficiency

>90%

Voltage regulation speed

<1s(when input voltage change 10%)

Frequency

50/60Hz

Enviroment

-5~40 below 90%

temperature,relative temperature

2(500VA), 4(1000VA), 6(1500VA), 8(2000VA)


12(3000VA), 20(5000VA), 25(7000VA), 40(10KVA)
85(15KVA), 73(20KVA), 109(30KVA)
1500V/1min

Rated maximum output current(A)


Withstand voltage

Standard: EN 61000-6-2 EN 61000-6-4 EN 61558-1


Certification: CE

Motor Control &


Protection

Overall Dimensions
Unit: mm

Power
Energy
Management
Power
Energy
Management

Product shape

Model

WideLengthHight

Desktop

HTND-0.5

W
190

L
160

H
135

HTND-1

205

190

155

HTND-1.5

205

190

155

HTND-2

240

270

200

HTND-3

225

305

235

HTND-5

225

310

290

HTND-7

240

387

360

HTND-10

240

387

360

HTND-10

310

340

535

HTND-15

340

360

640

HTND-20

340

380

780

HTND30

425

390

845


Cabinet type

289

SJW Three-phase Full Automatic


HSJW
AC Voltage Stabilizer

Function

SJW three-phase AC voltage stabilizer provide:


This product is constructed by connecting three stabilizers with Y-connection
Wide input voltage range, high efficiency, over-load protection, short adjusting
time, high regulation accuracy, same input and output voltage waveform, small
volume, less weight.
It's available in the electric equipments and facilities in housing, factory, shool,
shop, office and precision instrument for scientific experiment.

Order Information
Shape

Power rating

Desktop

Cabinet

Reference

1.5 kVA

SJW1P5

3 kVA

SJW3

4.5 kVA

SJW4P5

6 kVA

SJW6G

9 kVA

SJW9G

15 kVA

SJW15G

20 kVA

SJW20G

30 kVA

SJW30G

45 kVA

SJW45G

Technical Data
Type
Output voltage

HSJW 1.5KVA~60KVA
380V 4%

Low-voltage protection

340V7V(adjustable)

Over-voltage protection

420V 7V

Input voltage range

280~415V

Efficiency

90%

Voltage regulation speed

<1s(voltage fluctuation10%)

Frequency

50/60Hz

Waveform distortion:

No additional distortion

Withstand voltage

1500V/1min

Temperature rise

<+60

Environment temp.

-5~+40

Power Energy Management

Voltage regulation accuracy

Overall Dimensions

290

SJW Three-phase Full Automatic


HSJW
AC Voltage Stabilizer

Overall Dimensions

Cabinet

WORKING
PHASE A

WORKING
PHASE B

WORKING
PHASE C

PROTECT

OUTPUT VOLTAGE

VOLTAGE TEST

HSJW9 HIGH ACCURACY FULL-AUTOMATIC


AC VOLTAGE STABILIZER

Motor Control &


Protection

Shape

Power
Energy
Management
Power
Energy
Management

Desktop

Cabinet

291

Model

Wide x Length x Hight


W

HSJW-1P5

485

315

165

HSJW-3

485

315

165

HSJW-4.5

485

315

165

HSJW-6

278

322

665

HSJW-9

320

325

750

HSJW-15

350

350

855

HSJW-20

425

390

845

HSJW-30

440

415

875

HSJW-45

550

450

1170

HSJW-60

600

495

1300

HSBW Three-phase Compensation


AC Voltage Stabilizer
Function

SBW three-phase compensation AC voltage stabilizer provide:


This product is designed and developed with the international advanced
compensation technology. It can keep the output voltage in steady state
automatically when the network voltage uctuated or the load current varied.
It's provided with over-voltage, over-current, phase sequence protection function.

Order Information
Power rating

Reference

10kVA

SBW10

15kVA

SBW15

30kVA

SBW30

50kVA

SBW50

100kVA

SBW100

150kVA

SBW150

200kVA

SBW200

250kVA

SBW250

300kVA

SBW300

400kVA

SBW400

500kVA

SBW500

600kVA

SBW600

800kVA

SBW800

Technical Data

Output voltage

Power Energy Management

Type

SBW 10KVA~1600KVA
Voltage regulation accuracy

380V 3%

Low-voltage protection

340V 7V

Over-voltage protection

425V 7V

Input voltage range

304~456 V

Efciency

98%

Voltage regulation speed

<1s(voltage uctuation10%)

Frequency

50/60Hz

Waveform distortion

1%

Insulation resistance

2M

Withstand voltage
Temperature rise

2000V/1min
<+60

Environment temp.

-5~+40

292

HSBW Three-phase Compensation


AC Voltage Stabilizer

Overall Dimensions
Unit: mm

Motor Control &


Protection

Model

Power
Energy
Management
Power
Energy
Management

293

Wide x Length x Hight


W

HSBW-10

750

580

1170

HSBW-20

750

580

1170

HSBW-50

800

570

1300

HSBW-100

850

645

1460

HSBW-200

1050

750

1850

HSBW-500

1400

1100

2100

HSBW-800

1350

1100

2200

HSBW-1000

1050

750

2200

HSBW-1600

1300

1100

2200

Control Signal Overview

Indicator Light

LD11

295

IP degree:IP65
Specification

AC/DC: 6V 12V 24V 36V 48V 110V 220V 230V


AC: 220V 230V 380V
400V

Pushbutton Switches
LAY5
IP degree:IP55

299

LAY7
IP degree:IP55

309

Specification

Specification
AC-15: 380V/2A 220V
230V/3.3A

AC-15: 660V/1.1A

DC-13: 220V
230V/0.5A 110V/1.1A

380V
400V/2.0A 220V
230V/3.3A
DC-13: 440V/0.25A
220V
230V/0.5A 110V/1A

LAY8

315
Industrial Control
Components
Industrial
Control Components

IP degree:IP55
Specification
AC-15: 660V/1.5A
380V
400V/2.5A 220V
230V/4.5A
DC-13: 440V/0.2A
230V/0.4A
110V/0.8A
220V

294

HLD11 Indicator Light


Standard: IEC 60947-5

Function

HLD11 Series of indicator light provide:


Pilot signal, anticipating signals
Emergency signals and other instructions incidents signal use

Technical Data
Rated voltage(V)
Rated current(mA)
Working life(H)
Brightness of light(cd/m2)
Power frequency withstand voltage
Before board protect degree

AC/DC
6 12 24 36 48 110 220
50
30000
40
2500V AC 1min
IP65

AC
220 230 380
20

Order Information
Motor Control &
Protection

Installation
dimension
22:22

Type

Step-down
Type

A: Full cover 2: Resistance


head & long type
4: Capacitance
terminal
type

Button colour

Rated voltage

Reference

AC.DC 6V

HLD1122A21T7
HLD1122A21T3
HLD1122A21T4
HLD1122A21T5
HLD1122A21T8
HLD1122A21J7
HLD1122A21J3
HLD1122A21J4
HLD1122A21J5
HLD1122A21J8
HLD1122A21B7
HLD1122A21B3
HLD1122A21B4
HLD1122A21B5
HLD1122A21B8
HLD1122A21F7
HLD1122A21F3
HLD1122A21F4
HLD1122A21F5
HLD1122A21F8
HLD1122A21M7
HLD1122A21M3
HLD1122A21M4
HLD1122A21M5
HLD1122A21M8
HLD1122A41N7
HLD1122A41N3
HLD1122A41N4
HLD1122A41N5
HLD1122A41N8

AC.DC 12V
Power Energy
Management

AC.DC 24V

Industrial
Control
Components
Industrial
Control
Components

AC.DC 110V

AC.DC 220V

AC 230V

295

Overall Dimensions

Unit:mm

HLD11 Indicator Light


Standard: IEC 60947-5

Order Information
Installation
dimension

Type

Step-down
Type

Button colour

Rated voltage

Reference

AC 380V

HLD1122A41Q7

Overall Dimensions

Unit:mm

HLD1122A41Q3
HLD1122A41Q4
HLD1122A41Q5
HLD1122A41Q8
22:22

B: Half cover 2: Resistance


head&long
terminal

type
4: Capacitance

AC.DC 6V

HLD1122B21T7
HLD1122B21T3
HLD1122B21T4

type

HLD1122B21T5
HLD1122B21T8
AC.DC 12V

HLD1122B21J7
HLD1122B21J3
HLD1122B21J4
HLD1122B21J5
HLD1122B21J8

AC.DC 24V

HLD1122B21B7
HLD1122B21B3
HLD1122B21B4
HLD1122B21B5
HLD1122B21B8

AC.DC 110V

HLD1122B21F7
HLD1122B21F3
HLD1122B21F4
HLD1122B21F5
HLD1122B21F8

AC.DC 220V

HLD1122B21M7
HLD1122B21M3
HLD1122B21M4
HLD1122B21M5
HLD1122B21M8
HLD1122B41N7

Industrial Control
Components
Industrial
Control Components

AC 230V

HLD1122B41N3
HLD1122B41N4
HLD1122B41N5
HLD1122B41N8
AC 380V

HLD1122B41Q7
HLD1122B41Q3
HLD1122B41Q4
HLD1122B41Q5
HLD1122B41Q8

296

HLD11 Indicator Light


Standard: IEC 60947-5

Order Information
Installation
dimension
22:22

Type

Step-down
Type

C: Full cover 2: Resistance

Button colour

Rated voltage
AC.DC 6V

head & short type


terminal
4: Capacitance

Reference
HLD1122C21T7
HLD1122C21T3
HLD1122C21T4

type

HLD1122C21T5
HLD1122C21T8
AC.DC 12V

HLD1122C21J7
HLD1122C21J3
HLD1122C21J4
HLD1122C21J5
HLD1122C21J8

AC.DC 24V

HLD1122C21B7
HLD1122C21B3
HLD1122C21B4
HLD1122C21B5
HLD1122C21B8

AC 220V

HLD1122C41M7

Motor Control &


Protection

HLD1122C41M3
HLD1122C41M4
HLD1122C41M5
HLD1122C41M8
AC 230V

HLD1122C41N7
HLD1122C41N3
HLD1122C41N4

Power Energy
Management

HLD1122C41N5
HLD1122C41N8
AC 380V

HLD1122C41Q7
HLD1122C41Q3
HLD1122C41Q4
HLD1122C41Q5
HLD1122C41Q8

Industrial
Control
Components
Industrial
Control
Components

297

Overall Dimensions

Unit:mm

HLD11 Indicator Light


Standard: IEC 60947-5

Order Information

Installation
dimension

Type

Step-down

22:22

D: Half cover 2: Resistance

Type

Button colour

Rated voltage
AC.DC 6V

Reference

Overall Dimensions

Unit:mm

HLD1122D21T7

head&short

type

HLD1122D21T3

terminal

4: Capacitance
type

HLD1122D21T4
HLD1122D21T5
HLD1122D21T8
AC.DC 12V

HLD1122D21J7
HLD1122D21J3
HLD1122D21J4
HLD1122D21J5
HLD1122D21J8

AC.DC 24V

HLD1122D21B7
HLD1122D21B3
HLD1122D21B4
HLD1122D21B5
HLD1122D21B8

AC 220V

HLD1122D41M7
HLD1122D41M3
HLD1122D41M4
HLD1122D41M5
HLD1122D41M8

AC 230V

HLD1122D41N7
HLD1122D41N3
HLD1122D41N4
HLD1122D41N5
HLD1122D41N8

AC 380V

HLD1122D41Q7
HLD1122D41Q3
HLD1122D41Q4
HLD1122D41Q5
Industrial Control
Components
Industrial
Control Components

HLD1122D41Q8

298

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY5 series of pushbutton switches provide:


Control and indicate the status of the circuit

Technical Data
Usage mode

Rated valve

Rated voltage (Ue) V


AC-15
Rated current (Ie) A

380
2

220
3.3

Rated voltage (Ue) V


Rated current (Ie) A

220

110

0.5

1.1

DC-13

Mechanical endurance

3 0 Flush type , 1 0 Illuminated

105

1 Emergency stop, Selective-type, Key-tpye


Electric endurance

AC6( Flush type ) DC3( Illuminated )


1 Emergency stop, Selective-type, Key-tpye

105

Rated thermal current (Ith) A

Before board protect degree

IP55

Illuminated pushbutton
12

24

Ralative humidity

50%(40 )

90%(20

Above sea level

2000m

Pollution grade

Power supplier voltage

110

Motor Control &


Protection

LED
Neon lamp
Filament lamp

Power Energy
Management

Working Condition
Temperature

Industrial
Control
Components
Industrial
Control
Components

299

-5

~+40
)

220

380

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button
Name

Unit: MM
Material

Type

Color

NO + NC

1 White

1: 1NO

LAY5BA15

2 Black

2: 1NC

LAY5BA25

3 Green

3: 2NO

LAY5BA31

4 Red

4: 2NC

LAY5BA42

5 Yellow

5: 1NO+1NC

LAY5BA55

LAY5

B Metal

A Momentary

6 Blue

E Plastic

A Momentary

1 White

Dimension

LAY5BA65

1: 1NO

LAY5EA15

2 Black

2: 1NC

LAY5EA25

3 Green

3: 2NO

LAY5EA31

4 Red

4: 2NC

LAY5EA42

5 Yellow

5: 1NO+1NC

LAY5EA55

6 Blue

Selective Button Switch


Name

Reference

LAY5EA65

Unit: MM
Material

Type

B Metal

D Selective
button with
short handle

Operation

NO + NC

LAY5

2:2p
3:3p

C R
L C R
C R

5:3p

L C R

1: 1NO

LAY5BD21

2: 1NC

LAY5BD25

3: 2NO

LAY5BD33

4: 2NC

LAY5BD45

5: 1NO+1NC

LAY5BD53

Dimension

Industrial Control
Components
Industrial
Control Components

4:2 p

Reference

300

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Selective Switches
Name
Material

Unit: MM
Operation

Type

NO + NC

LAY5

E Plastic

D Selective
switch with
short handle

2:2 p
3:3 p

C R
L C R

C R
4:2
short
handl
handl
p short
eshort
e handl

Reference

1: 1NO

LAY5ED21

2: 1NC

LAY5ED25

3: 2NO

LAY5ED33

4: 2NC

LAY5ED45

5: 1NO+1NC

LAY5ED55

L handl
C R
5:3
short
handl
p short
eshort
e handl

B Metal

J Selective
switch with
Emergency
shortshort
handl
short
handlhandl
short
handle

2:2 p
3:3 p

C R
L C R

Motor Control &


Protection

C R
4:2
short
handl
handl
p short
eshort
e handl

1: 1NO

LAY5BJ21

2: 1NC

LAY5BJ25

3: 2NO

LAY5BJ33

4: 2NC

LAY5BJ45

5: 1NO+1NC

LAY5BJ55

L handl
C R
5:3
short
handl
p short
eshort
e handl

E Plastic

J Selective

Power Energy
Management

switch with
Emergency
shortshort
handl
short
handlhandl
short
handle

2:2 p
3:3 p

C R
L C R

short
handl
handl
p short
eshort
e handl
4:2
C R
short
handl
p short
eshort
e handl
5:3
L handl
C R

Industrial
Control
Components
Industrial
Control
Components

301

1: 1NO

LAY5EJ21

2: 1NC
3: 2NO

LAY5EJ25
LAY5EJ33

4: 2NC

LAY5EJ45

5: 1NO+1NC

LAY5EJ55

Dimension

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switches
Name

Material

Unit: MM
Operation

Type

NO + NC

LAY5

B Metal

E Plastic

G Key-operated 2:2 p
selective
switches
3:3 p

C R

1: 1NO

LAY5BG21

2: 1NC

LAY5BG25

L C R

3: 2NO

LAY5BG33

4: 2NC

LAY5BG45

5: 1NO+1NC

LAY5BG55

4:2p reset

C R

5:3 p reset

L C R

C R

G Key-operated 2:2p
selective
switches
3:3 p

Reference

L C R

4:2p reset

C R

5:3 p reset

L C R

1: 1NO

LAY5EG21

2: 1NC

LAY5EG25

3: 2NO

LAY5EG33

4: 2NC

LAY5EG45

5: 1NO+1NC

LAY5EG55

Mushroom Button
Name

Dimension

Unit: MM
Material

Color

40 Mushroom

3 Green
4 Red

NO + NC

LAY5

B Metal

C:

Reference

1: 1NO

LAY5BC31

2: 1NC

LAY5BC42

3: 2NO

LAY5BC35

4: 2NC

LAY5BC45

Dimension

Industrial Control
Components
Industrial
Control Components

Type

5: 1NO+1NC

302

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Mushroom Button
Name
LAY5

Unit: MM
Material

B Metal

R:

Type

Color

60 Mushroom

3 Green
4 Red

NO + NC

Reference

1: 1NO

LAY5BR31

2: 1NC

LAY5BR42

3: 2NO

LAY5BR35

4: 2NC

LAY5BR45

5: 1NO+1NC

E Plastic

C:

40 Mushroom

3 Green
4 Red

Motor Control &


Protection

1: 1NO

LAY5EC31

2: 1NC

LAY5EC42

3: 2NO

LAY5EC35

4: 2NC

LAY5EC45

5: 1NO+1NC

Power Energy
Management

E Plastic

R:

60 Mushroom

3 Green
4 Red

1: 1NO

LAY5ER31

2: 1NC

LAY5ER42

3: 2NO

LAY5ER35

4: 2NC

LAY5ER45

5: 1NO+1NC

Industrial
Control
Components
Industrial
Control
Components

303

Dimension

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button
Name

Material

Unit: MM
Type

Head

Color

NO + NC

3 Green

1: 1NO

LAY5BS431

4 Red

2: 1NC

LAY5BS442

3: 2NO

LAY5BS435

4: 2NC

LAY5BS445

LAY5

B Metal

S: Emergency

4:

30

Reference

Dimension

5: 1NO+1NC

B Metal

S: Emergency

5:

40

3 Green

1: 1NO

LAY5BS531

4 Red

2: 1NC

LAY5BS542

3: 2NO

LAY5BS535

4: 2NC

LAY5BS545

5: 1NO+1NC

B Metal

S: Emergency

6:

60

3 Green

1: 1NO

LAY5BS631

4 Red

2: 1NC

LAY5BS642

3: 2NO

LAY5BS635

4: 2NC

LAY5BS645

5: 1NO+1NC

Industrial Control
Components
Industrial
Control Components

304

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Emergency Stop Button
Name

Unit: MM

Material

Type

E Plastic

S: Emergency

Head

Color

NO + NC

LAY5

4:

30

Reference

3 Green

1: 1NO

LAY5ES431

4 Red

2: 1NC

LAY5ES442

3: 2NO

LAY5ES435

4: 2NC

LAY5ES445

5: 1NO+1NC

E Plastic

S: Emergency

5:

40

1: 1NO

LAY5ES531

4 Red

2: 1NC

LAY5ES542

3: 2NO

LAY5ES535

4: 2NC

LAY5ES545

Motor Control &


Protection

3 Green

5: 1NO+1NC

Power Energy
Management

E Plastic

S: Emergency

6:

60

3 Green

1: 1NO

LAY5ES631

4 Red

2: 1NC

LAY5ES642

3: 2NO

LAY5ES635

4: 2NC

LAY5ES645

5: 1NO+1NC

Industrial
Control
Components
Industrial
Control
Components

305

Dimension

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Two-head Button
Name

Material

Type

Head

No.of head

NO + NC

LAY5

Reference

B Metal

L8: Two-head 3: Flush button

2: 2

5: 1NO+1NC

LAY5BL8325

B Metal

L8 : Two-head 4: One high,


one low

2: 2

5: 1NO+1NC

LAY5BL8425

Dimension

Industrial Control
Components
Industrial
Control Components

306

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Illuminated Pushbutton Switches


Name

Material

Type

Color

Voltage

LAY5

NO + NC

*
B Metal

W3 Flush

Light

1 White

T:6V

1: 1NO

3 Green

N Neon

B:24V

2: 1NC

L LED

4 Red

F:110V

3: 2NO

5 Yellow

Blank:

N:230V
M:220V

4: 2NC

6 Blue

Q:380V

5: 1NO+1NC

Filament

T:6V

5: 1NO+1NC N Neon

7 Pure white
8 Pure blue

B Metal

W8:Two
head

4 One high
one low

Motor Control &


Protection

B:24V

L LED

F:110V

Blank:

N:230V
M:220V

Power Energy
Management

W3 Flush

T:6V

1: 1NO

N Neon

LAY5EW31*5

B:24V

2: 1NC

L LED

LAY5EW33*1

4 Red

F:110V

3: 2NO

M:220V
N:230V

Blank:

5 Yellow

4: 2NC

Q:380V

Filament

6 Blue

5: 1NO+1NC

T:6V

5: 1NO+1NC N Neon

Industrial
Control
Components
Industrial
Control
Components

4 One high
one low

B:24V

L LED

F:110V

Blank:
Filament

M:220V
N:230V
Q:380V

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.

307

LAY5BW84*5*

3 Green

8 Pure blue

W8:Two
head

*
*
LAY5BW34*2
*
LAY5BW35*5
*
LAY5BW36*5
*
LAY5BW37*5
*
LAY5BW38*5
*
LAY5BW33*1

1 White

7 Pure white

E Plastic

LAY5BW31*5

Filament

Q:380V

E Plastic

Reference

*
*
LAY5EW34*2
*
LAY5EW35*5
*
LAY5EW36*5
*
LAY5EW37*5
*
LAY5EW38*5
*

LAY5EW84*5*

Dimension

LAY5 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Indication Lamp
Name

Unit: MM
Material

Type

LAY5

Voltage

Color

*
B Metal

V: Indication

Light

T:6V

1 White

N Neon

B:24V

3 Green

L LED

F:110V

4 Red
5 Yellow

Blank:

N:230V
M:220V
Q:380V

6 Blue
7 Pure white
8 Pure blue

Filament

Reference

Dimension

LAY5BV*1*
LAY5BV*3*
LAY5BV*4*
LAY5BV*5*
LAY5BV*6*
LAY5BV*7*
LAY5BV*8*

Base
Name

Type

Contact

LAY5

BE Auxiliary contact

Reference

101: 1NO

LAY5BE101

102: 1NC

LAY5BE102

103: 2NO

LAY5BE103

104: 2NC

LAY5BE104

105: 1N0+1NC

LAY5BE105

Dimension

Note : Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V

The pure white and pure blue are only available for LED lamp .

Industrial Control
Components
Industrial
Control Components

308

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY7 series of pushbutton switches provide:


Control and indicate the status of the circuit

Technical Data
Usage mode

Rated valve

Rated voltage (Ue) V


AC-15 Rated current (Ie) A

660

380

230
220

1.1

3.3

Rated voltage (Ue) V


Rated current (Ie) A

440

230
220

110

0.25

0.5

DC-13

Mechanical endurance 105

3 0 Flush type , 1 0 Illuminated


0 . 5 Emergency stop, Selective-type,, Key-tpye

Electric endurance

6 Flush type , 1 Illuminated


0 . 5 Emergency stop,, Selective-type,, Key-tpye

105

Rated thermal current l

th

Operation frequency

T /h

10
1200

m
Contact resistance
50
Before board protect degree IP55
Illuminated pushbutton
Motor Control &
Protection

Power supplier voltage


Working voltage
Lifetime

(Ue)V
h

Filament lamp

Neon lamp

LED

6, 12, 24

110, 220, 380

6, 12, 24

1000

2000

3000

Power Energy
Management

Working Condition
Temperature

-5

Ralative humidity

50%(40 )

Above sea level

2000m
3

Industrial
Control
Components
Industrial
Control
Components

Pollution grade

309

~+40
90%(20

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Flush Button
Name

Unit: MM
Type

NO + NC

Color

Installation

LAY7

BN Momentary

Reference

1 White
2 Black

22

LAY711BN12

01: 1NC

25

LAY711BN22

20: 2NO

3 Green

30

LAY711BN32

02: 2NC

4 Red

11: 1NO+1NC

5 Yellow

LAY711BN52

6 Blue

LAY711BN62

10: 1NO

10: 1NO

BNZS Maintained

01: 1NC

LAY711BN42

3 Green

22

LAY711BNZS32

4 Red

25

LAY711BNZS42

30

3 Green

22

LAY711GN32

4 Red

25

LAY711GN42

30

3 Green

22

LAY711GNZS32

4 Red

25

LAY711GNZS42

30

20: 2NO

Dimension

02: 2NC
11: 1NO+1NC

10: 1NO

GN Momentary

01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC

10: 1NO

GNZS Maintained

20: 2NO

Industrial Control
Components
Industrial
Control Components

01: 1NC
02: 2NC
11: 1NO+1NC

310

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Flush Button
Name
LAY7

NO + NC

Type

10: 1NO

JN Full protection

Installation

Color

01: 1NC

Reference

3 Green

22

LAY711JN32

4 Red

25

LAY711JN42

30

20: 2NO

Dimension

02: 2NC
11: 1NO+1NC

Unit: MM

Selective Switches
Name

NO + NC

Color

Operation

Type

Installation

LAY7
Motor Control &
Protection

10: 1NO

20:2p

01: 1NC

X Selective
button with

20: 2NO

short handle 21:2p reset

C R 2 Black 2
3 Green 3

22

LAY711X2022

25

LAY711X2132

30

LAY711X3042

C R 4 Red

LAY711X3122

02: 2NC
11: 1NO+1NC

Reference

30:3p

LAY720X3022

L C R

Power Energy
Management

31:3p reset L C R
33:3p reset L C R

10: 1NO
Industrial
Control
Components
Industrial
Control
Components

01: 1NC
20: 2NO

XB Selective 20:2p
button with
long handle 21:2p reset

C R 2 Black

LAY711XB2022

25

LAY711XB2132

30

LAY711XB3042

Red

LAY720XB3022
30:3p

L C R

31:3p reset L C R
33:3p reset L C R

311

22

C R 4

02: 2NC
11: 1NO+1NC

3 Green 3

LAY720XB3322

Dimension

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switches
Name

Unit: MM

NO + NC

Type

10: 1NO

Y Key-operated

Installation

Operation

LAY7

Reference

22

LAY711Y202

01: 1NC

25

LAY711Y212

20: 2NO

30

LAY711Y302

20:2p

C R

21:2 preset

C R

Dimension

LAY711Y312

02: 2NC
30:3p

11: 1NO+1NC

LAY720Y332

L C R

31:3 preset L C R
33:3 preset L C R

Unit: MM

Mushroom Button
Name

NO + NC

Type

Color

Installation

LAY7

10: 1NO

M Momentary

01: 1NC

Reference

3 Green

22

LAY711M32

4 Red

25

LAY711M42

30

3 Green

22

LAY711MZS32

4 Red

25

LAY711MZS42

30

20: 2NO

Dimension

02: 2NC
11: 1NO+1NC

10: 1NO
01: 1NC

Industrial Control
Components
Industrial
Control Components

20: 2NO

MZS Maintained

02: 2NC
11: 1NO+1NC

312

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: M

Emergency Stop Button


Name

NO + NC

Type

Installation

Color

LAY7

10: 1NO

ZS:Emergency

01: NC
20: 2NC

3: Green
4: Red

2: 22
3: 25
4: 30

02: 2NC
11: 1NO+1NC

Reference

Dimension

LAY710ZS32
LAY701ZS42

LAY711ZS32
LAY711ZS42

Unit: M

Illuminated Pushbutton Switches


Name

NO + NC

Type

Color

LAY7

Voltage

Installation

Motor Control &


Protection
Power Energy
Management

10: 1NO
D: Momentary
01: NC
(Illuminated)
20: 2NC
02: 2NC
11: 1NO+1NC

3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue

2: 22
T: 6V
B: 24V 3: 25
F: 110V 4: 30
M: 220V
Q: 380V

10: 1NO
DZS: Maintained
01: NC
(Illuminated)
20: 2NC
02: 2NC
11: 1NO+1NC

3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue

T: 6V
2: 22
B: 24V 3: 25
F: 110V 4: 30
M: 220V
Q: 380V

Light

N Neon
L LED
Blank:
Filament

N Neon
L LED
Blank:
Filament

Reference

Dimension

LAY711D3*2 *
LAY711D4*2 *
LAY711D5*2

*
*
LAY711D7*2
*
LAY711D8*2
*
LAY711D6*2

LAY711DZS2*2
3 *

LAY711DZS4*2*
LAY711DZS5*2*
LAY711DZS6*2*
LAY711DZS7*2 *

LAY711DZS8*2*

10: 1NO
01: NC

DM: Momentary
(Illuminated)

3: Green
4: Red

Industrial
Control
Components
Industrial
Control
Components

20: 2NC
02: 2NC
11: 1NO+1NC

10: 1NO
01: NC
20: 2NC
02: 2NC
11: 1NO+1NC

DMZS: Maintained 3: Green


4: Red
(Illuminated)

T: 6V
2: 22
B: 24V 3: 25
F: 110V 4: 30
M: 220V
Q: 380V

T: 6V
2: 22
B: 24V 3: 25
F: 110V 4: 30
M: 220V
Q: 380V

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.

313

N Neon
L LED
Blank:

LAY711DM3*2 *
LAY711DM4*2

Filament

N Neon

LAY711DMZS3*2

L LED

LAY711DMZS4*2

Blank:
Filament

*
*

HLAY7 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Illuminated Selective Switches
Name

NO + NC

Unit: MM
Operation

Type

Light

Color Voltage Install

LAY7

*
XD: Selective 20:2p
(Illuminated)

10: 1NO
01: 1NC

C R

Reference

3 Green

T: 6V

22

N Neon

LAY711XD203*2

4 Red

B: 24V

25

L LED

LAY711XD204*2

F: 110V

30

Blank:
Filament

20: 2NO
02: 2NC

30:3p L C R

M:220V
N:
230V
Q: 380V

11: 1NO+1NC

*
*
LAY711XD303*2
*
LAY711XD304*2
*

Indication Lamp
Name

Dimension

Unit: MM
Type

Color

Voltage

Install

LAY7

Reference

XD1 Filament

1 White

T: 6V

XD2 Neon

3 Green

B: 24V

LAY7XD23*2

XD3 LED

4 Red

F: 110V

LAY7XD34*2

5 Yellow

M:220V
N:
230V

LAY7XD15*2

6 Blue

Q: 380V

LAY7XD26*2

22

Dimension

LAY7XD11*2

7 Pure white

LAY7XD37*2

8 Pure blue

LAY7XD38*2

Base

Unit: MM

Name

Type

Contact

LAY7

101: 1NO

LAY7BE101

102: 1NC

LAY7BE102

103: 2NO

LAY7BE103

104: 2NC

LAY7BE104

105: 1N0+1NC

LAY7BE105

Dimension
Industrial Control
Components
Industrial
Control Components

BE Auxiliary contact

Reference

Note: Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V
The pure white and pure blue are only available for LED lamp.

314

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Function

LAY8 series of pushbutton switches provide:


Control and indicate the status of the circuit

Technical Data
Usage mode

Rated valve

AC-15

Rated voltage (Ue) V


Rated current (Ie) A

DC-13

Rated voltage (Ue) V


Rated current (Ie) A

660

380

220

1.5

2.5

4.5

440

220

11
110
0.8

0.4

0.2

Mechanical endurance 105

3 0 Flush type

3 Selective ,

0 . 5 Emergency stop, Key-tpye


Electric endurance

105

6( Flush type ) 1( Illuminated ) ,

Rated thermal current(Ith)A

0 . 5 Emergency stop, Key-tpye


10

Contact resistance
m
Before board protect degree

50
IP55

Illuminated pushbutton
Rated working voltage(Ue)V 6

12

24

36

AC,DC
Rated working current (Ie)mA 50

Motor Control &


Protection

Working Condition
Power Energy
Management
Industrial
Control
Components
Industrial
Control
Components

315

-5

Ralative humidity

50%(40 )

Above sea level

2000m

Pollution grade

110

220
AC
20

Power supply

Temperature

48

~+40
90%(20

230

380

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Flush Button
Name
LAY8

NO + NC

Type

10: 1NO

BN Momentary

01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC

10: 1NO

BNZS Maintained

01: 1NC
20: 2NO

Color

1 White
2 Black

Reference

Dimension

LAY811BN1
LAY811BN2

3 Green

LAY811BN3

4 Red
5 Yellow

LAY811BN4

6 Blue

LAY811BN6

LAY811BN5

3 Green

LAY811BNZS3

4 Red
5 Yellow

LAY811BNZS4

3 Green

LAY811S3

4 Red
5 Yellow

LAY811S4

LAY811BNZS5

02: 2NC
11: 1NO+1NC

10: 1NO
01: 1NC
20: 2NO

S Waterproof

LAY811S5

02: 2NC
11: 1NO+1NC

Industrial Control
Components
Industrial
Control Components

316

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Selective Switches
Name

NO + NC

Type

10: 1NO

X Selective
button with
short handle

Color

Operation

LAY8

01: 1NC
20: 2NO

20:2p
21:2 p reset

C R
C R

Reference

2 Black

LAY811X202

3 Green

LAY811X213

4 Red

LAY811X304

02: 2NC

LAY811X312

11: 1NO+1NC

30:3p

LAY820X332

L C R

31:3p reset L C R
33:3p reset L C R

Motor Control &


Protection

10: 1NO

XB Selective

01: 1NC

button with

20: 2NO

long handle

20:2p
21:2p reset

C R
C R

02: 2NC
11: 1NO+1NC

LAY811XB202

3 Green

LAY811XB213

4 Red

LAY811XB304
LAY811XB312

30:3p

L C R

31:3p reset L C R

Power Energy
Management

33:3p reset L C R

Industrial
Control
Components
Industrial
Control
Components

317

2 Black

LAY820XB332

Dimension

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Key-operated Selective Switch
Name

NO + NC

Unit: MM
Type

Operation

Reference

LAY8

10: 1NO

Y Key-operated

20:2p

C R

21:2 p reset

C R

01: 1NC

Dimension

LAY811Y20
LAY811Y21

20: 2NO
02: 2NC

LAY820Y30
LAY811Y31

30:3p

11: 1NO+1NC

L C R

LAY811Y33

31:3 p reset L C R
33:3 p reset L C R

Mushroom Button
Name

Unit: MM
NO + NC

Type

10: 1NO

M Momentary

Color

LAY8

01: 1NC

Reference

3 Green

LAY811M3

4 Red

LAY811M4

Dimension

20: 2NO
02: 2NC
11: 1NO+1NC

10: 1NO
01: 1NC

MZS Maintained

3 Green
4 Red

LAY811MZS3
LAY811MZS4
Industrial Control
Components
Industrial
Control Components

20: 2NO
02: 2NC
11: 1NO+1NC

318

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Emergency Stop Button


Name

Type

NO + NC

Color

Reference

LAY8

ZS Emergency

10: 1NO
01: 1NC

3 Green

LAY811ZS3

4 Red

LAY811ZS4

Dimension

20: 2NO
02: 2NC
11: 1NO+1NC

Unit: MM

Illuminated Pushbutton Switches


Name
LAY8

NO + NC

Type

Color

Voltage

Power

Motor Control &


Protection

10: 1NO

D: Momentary

01: 1NC

(Illuminated)

20: 2NO
02: 2NC
11: 1NO+1NC

3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue

T: 6V
B: 24V
F: 110V
M: 220V
Q: 380V

2: AC/DC
4: AC

Reference

LAY811D3*4
LAY811D4*4
LAY811D5*2
LAY811D6*2
LAY811D7*2
LAY811D8*2

Power Energy
Management

10: 1NO
01: 1NC

DZS: Maintained
(Illuminated)

20: 2NO
02: 2NC
11: 1NO+1NC

3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue

T: 6V
B: 24V
F: 110V
M: 220V
Q: 380V

2: AC/DC
4: AC

LAY811DZS3*4
LAY811DZS4*4
LAY811DZS5*2
LAY811DZS6*2
LAY811DZS7*4
LAY811DZS8*4

Industrial
Control
Components
Industrial
Control
Components

10: 1NO
01: 1NC
20: 2NO
02: 2NC
11: 1NO+1NC

DS:Waterproof
(Illuminated)

3: Green
4: Red
5: Yellow
6:Blue
7:Pure white
8:Pure blue

T: 6V
B: 24V
F: 110V
M: 220V
Q: 380V

Note:Supplier voltage code: T:6V, B:24V, F:110V, M:220V, N:230V, Q:380V


The pure white and pure blue are only available for LED lamp.

319

2: AC/DC
4: AC

LAY811DS3*4
LAY811DS4*4
LAY811DS5*2

Dimension

HLAY8 Pushbutton Switches


Standard: IEC 60947-5

Order Information
Unit: MM

Base
Name
LAY8

Type

BE Auxiliary contact

Contact

Reference

101: 1NO

LAY8BE101

102: 1NC

LAY8BE102

103: 2NO

LAY8BE103

104: 2NC

LAY8BE104

105: 1N0+1NC

LAY8BE105

Dimension

Industrial Control
Components
Industrial
Control Components

320

HRT16 Fuse
Standard: IEC 60269

Function

RT16 fuse provide:


Protection of circuits against overload current
Protection of circuits against short-circuit current

Order Information
Fuse-link
HRT16-00

Rate current In(A) Suitable fuse bases


2

HRT16-00

Weight(g)

Reference

170

HRT16002

Motor Control &


Protection

HRT16004

HRT16006

HRT16008

10

HRT160010

12

HRT160012

16

HRT160016

20

HRT160020

25

HRT160025

32

HRT160032

40

HRT160040

50

HRT160050

63

HRT160063

80

HRT160080

100

HRT1600100

125

HRT1600125

160
HRT16-1

80

HRT1600160
HRT16-1

450

Power Energy
Management

HRT161100

125

HRT161125

160

HRT161160

200

HRT161200

250
HRT16-2

125

HRT161250
HRT16-2

660

Industrial
Control
Components
Industrial
Control
Components

321

HRT162125

160

HRT162160

200

HRT162200

250

HRT162250

300

HRT162300

315

HRT162315

355

HRT162355

400
HRT16-3

HRT16180

100

315

HRT162400
HRT16-3

850

HRT163315

355

HRT163355

400

HRT163400

450

HRT163450

500

HRT163500

630

HRT163630

HRT16 Fuse
Standard: IEC 60269

Order Information
Fuse Base
RT16-00

Rate current In(A)

Material

Weight(g)

Reference

160

Ceramic

200

RT1600ZT
RT1600ZS

Resin
RT16-1

250

RT161ZT

700

Ceramic

RT161ZS

Resin
RT16-2

400

RT162ZT

1150

Ceramic

RT162ZS

Resin
RT16-3

630

RT163ZT

1280

Ceramic

RT163ZS

Resin

Technical Data
Rated working current

2-630A

Rated operation voltage

500/690V

Rated breaking capacity

Accessory-puller
Material

Usage

Reference

ABS(frame resistance)

Assemble and replace HRT16 fuse

HRT16C

Industrial Control
Components
Industrial
Control Components

322

HRT16 Fuse
Standard: IEC 60269

Overall Dimensions
Unit: mm

Type

HRT16-1

HRT16-2

HRT16-3

Motor Control &


Protection
Power Energy
Management

78.5

135

150

150

29

48

58

67

57

62

72

85

49

67

67

67

30

58

64

64

120

200

250

250

C1

61

83

99

105

C2

85

96

112

120

100

175

200

210

25

25

25

25

7.5

10.5

10.5

10.5

30

30

30

Industrial
Control
Components
Industrial
Control
Components

323

HRT16-00

HRT18 Fuse
Standard: IEC 60269

Function

RT18 fuse provide:


Protection of circuits against overload current
Protection of circuits against short-circuit current

Order Information
Cylindrical Fuse
RT18-32

Rate current In(A)

Weight(g)

RT1810382

RT1810384

RT1810386

RT1810388

10

RT18103810

12

RT18103812

16

RT18103816

20

RT18103820

25

RT18103825

32
RT18-63

Reference

RT18103832
20

RT1814512

RT1814514

RT1814516

RT1814518

10

RT18145110

12

RT18145112

16

RT18145116

20

RT18145120

25

RT18145125

32

RT18145132

40

RT18145140

50

RT18145150

63

RT18145163

Industrial Control
Components
Industrial
Control Components

324

HRT18 Fuse
Standard: IEC 60269

Order Information

Holder of fuse
RT18-32X

Pole

Rate current
In(A)

Note

Weight
(g)

Reference

1P

32

Material:Resin

82

RT1832ZXB

With Indicator

2P

RT1832Z2XB

3P
RT18-32

1P

RT1832Z3XB
Material:Resin

32

2P

82

3P
RT18-32X

1P

RT1832Z3B
Material:Nylon

32

2P

82

With Indicator

1P

RT1832Z3X
Material:Nylon

32

2P

82

Motor Control &


Protection

1P

RT1832Z3
Material:Resin

63

2P

206

With Indicator

1P

RT1863Z3XB
Material:Resin

63

2P

Without Indicator

3P

206

RT1863ZB
RT1863Z2B
RT1863Z3B

Power Energy
Management

Technical Data

Industrial
Control
Components
Industrial
Control
Components

325

RT1863ZXB
RT1863Z2XB

3P
RT18-63

RT1832Z
RT1832Z2

Without Indicator

3P
RT18-63X

RT1832ZX
RT1832Z2X

3P
RT18-32

RT1832ZB
RT1832Z2B

Without Indicator

Rated working current

2-63A

Rated operation voltage

380V

Rated breaking capacity

100KA

HRT18 Fuse
Standard: IEC 60269

Overall Dimensions
Unit: mm

Cylindrical Fuse
Type
RT18-32
RT18-63

Size

Hmax

1038

380.6

10.30.1

10.5

1451

+0.6
-1.0

14.30.1

13.8

51

Holder of fuse
Type

63

60

79

35

80

18

54

RT18-63

78

76

103

35

110

25

75

Industrial Control
Components
Industrial
Control Components

RT18-32

326

Industrial Plugs&Sockets Overview

HDPM Moving Industrial plugs


Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A

HDP Fixed Industrial Plugs

328

329

Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A

HDSM Moving Industrial Sockets

330

Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
Motor Control &
Protection

HDSF Fixed Industrial Sockets

331

Pole: 2P+E~3P+N+E
Voltage:110~415V
Current:16,32,63,125A
Power Energy
Management

HDPS Multi-function Plugs and Sockets

Industrial
Control
Components
Industrial
Control
Components

Pole: 2P+E
Voltage:110V, 230V
Current:16A

327

332

HDPM Moving Industrial Plugs


Standard: IEC 60309-1-2

Moving Industrial Plugs

16Amp

32Amp

63

CDPM363IP67

125

CDPM3125IP67

63

CDPM463IP67

125

CDPM4125IP67

230-400

63

CDPM563IP67

240-415

125

CDPM5125IP67

PG

67

230-250

2P+E
63Amp
3

a
b
c

125Amp
3

230 230 230

295 295 295

109 109 109

124 124 124

36 36 36

50 50 50

67

400-415

3P+E

3P+N+E

328

Industrial Control
Components
Industrial
Control Components

67

HDP Fixed Industrial Plugs


Standard: IEC 60309-1-2

Fixed Industrial Plugs

CDP316IP441

CDP332IP441

CDP316IP44

CDP332IP44

CDP416IP44

CDP432IP44
Motor Control &
Protection

CDP516IP44

CDP532IP44

Power Energy
Management

67

230~250

63

CDP363IP67

67

400~415

63

HDP463IP67

230-400

63

HDP563IP67

240-415

125

HDP5125IP67

63Amp

Industrial
Control
Components
Industrial
Control
Components

a
b
c
d
e
f
g
h
PG

3
193

4
193

5
193

122
157

122
157

122
157

109
19

109
19

109
19

6
288

6
288

6
288

127
29

127
29

127
29

3P+E

67
3P+N+E

329

HDSM Moving Industrial Sockets

Standard: IEC 60309-1-2

Moving Industrial Sockets

CDSM316IP441

16Amp

32Amp

Poles

130 131 139 149 149 154

66

76

90

90

90

100

67
b

PG

63

CDSM363IP67

125

CDSM3125IP67

63

CDSM463IP67

125

CDSM4125IP67

230-400

63

CDSM563IP67

240-415

125

CDSM5125IP67

230~250

2P+E

67

400~415

3P+E
63Amp
3
b
PG

240 240 240


112 112 112
36 36 36

300 300 300


126 126 126
50 50 50

67
3P+N+E

330

Industrial Control
Components
Industrial
Control Components

125Amp

HDSF Fixed Industrial Sockets


Standard: IEC 60309-1-2

Fixed Industrial Sockets


Pole No.

IP

44

Nominal
voltage(V)

DSF316IP441

32

DSF332IP441

16

DSF316IP44

32

DSF332IP44

16

DSF416IP44

32

DSF432IP44

230~400

16

DSF516IP44

240~415

32

DSF532IP44

63

DSF363IP67

125

DSF3125IP67

63

DSF463IP67

125

DSF4125IP67

230~400

63

DSF563IP67

240~415

125

DSF5125IP67

110~130

230~250

2P+E

Motor Control &


Protection

44

32Amp

16Amp
Poles

128 128 129

86

90

96

97

97 104

25

25

25

25

25

400~415

3P+E

141 141 143

25
3P+N+E

44

Power Energy
Management

67

230~250

2P+E

Industrial
Control
Components
Industrial
Control
Components

125Amp

63Amp
Poles

3P+E

193 193 193

220 220 220

122 122 122

140 140 140

157 157 157

185 185 185

109 109 109

130 130 130

19

19

19

17

17 17

270 270 270

320 320 320

130 130 130

150 150 150

PG

331

29

29

29

36

67

400~415

36 36

Reference

16
2P+E

44

Nominal
current(A)

67
3P+N+E

HDPS Multi-function Plugs&Sockets


Standard: IEC 60309-1-2

Multi-function Plugs and Sockets

1 Plug

1 Plug

1 Plug

1 Plug

Industrial Control
Components
Industrial
Control Components

332

Copper Terminal Block Overview

HTB010

335

Hole:4, 6, 8, 10, 12, 14, 16


Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150

HTB019

336

Hole:4, 6, 8, 10, 12, 14, 16


Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150

HTB007

337

Motor Control &


Protection

Hole:6, 8, 10, 12, 14, 16


Hole diameter(mm):5.2, 6
Screw dimension(mm):M4*8, M5*10
Max current(A):100, 150

HTB043

338

Power Energy
Management

Hole:78, 109, 116, 133


Hole diameter(mm):5~9
Screw dimension(mm):M4*8~M6*12
Max current(A):100~200

Industrial
Control
Components
Industrial
Control
Components

HTB112

338

Hole:2x7, 2x15, 4x7, 4x11, 4x15


Hole diameter(mm):5.2
Screw dimension(mm):M4
Max current(A):125

333

HCF Series Cable Connector

Technical Data
Thread specication: International metric standard
Material: Nylon 66
Working temp.: -40~+100
Max temp. in short time: +120.
Installation: Standard threaded hole
Colour: Black & gray

Order Information
Cabel
range (mm)

Thread external
diameter (mm)

Panel hole
(mm)

Thread
length (mm)

Spanner size
A&F

Reference
Black

Gray

7.6-4.6

12

12.5

8.5

18/19

CCFMG12IP68B

CCFMG12IP68W

10-6

16

16.5

15

22/22

CCFMG16IP68B

CCFMG16IP68W

14-9

20

20.5

15

27/27

CCFMG20IP68B

CCFMG20IP68W

18-13

25

25.5

15

33/33

CCFMG25IP68B

CCFMG25IP68W

25-18

32

33

15

41/41

CCFMG32IP68B

CCFMG32IP68W

30-24

40

41

20

50/50

CCFMG40IP68B

CCFMG40IP68W

41-30

50

51

22

62/62

CCFMG50IP68B

CCFMG50IP68W

51-40

63

64

25

75/75

CCFMG63IP68B

CCFMG63IP68W

7-3.5

12.5

17/19

---

CFPG7IP54W
CFPG9IP54W
CCFPG11IP54W

8-4.5

15.2

8.5

22/19

---

10.5-6

11

18.6

24/22

---

12.5-7.5

13.5

20.4

9.6

27/24

---

14-8.5

16

22.5

10

30/27

---

CFPG16IP54W

18-12.5

21

28.3

12

36/33

---

CCFPG21IP54W

25-18

29

37

15

46/41

---

CCFPG29IP54W

30-23

36

47

15

57/50

---

CCFPG36IP54W

39-30

42

54

15.5

64/62

---

CCFPG42IP54W

45-35

48

59.3

15.5

70/65

---

CCFPG48IP54W

CFPG135IP54W

Industrial Control
Components
Industrial
Control Components

334

HTB010 Series Copper Terminal Block

Order Information

Motor Control &


Protection

Power Energy
Management

Industrial
Control
Components
Industrial
Control
Components

335

HTB019 Series Copper Terminal Block

Order Information

Industrial Control
Components
Industrial
Control Components

336

HTB007 Series Copper Terminal Block

Order Information

Motor Control &


Protection

Power Energy
Management

Industrial
Control
Components
Industrial
Control
Components

337

HTB112 Series Copper Terminal Blocks


HTB043 Series Copper Terminal Blocks

Order Information

65
132
65
132

Industrial Control
Components
Industrial
Control Components

338

HDIN Rail Series

Order Information

Thickness(mm)

1.0

Length

Material

Reference

1000mm

Aluminum

HDIN02T1000

2000MM

Aluminum

HDIN02T2000

1000mm

Steel

HDIN12T1000

2000MM

Steel

HDIN12T2000

Overall Dimensions
Unit:mm
Motor Control &
Protection

6.0

18

Power Energy
Management
Industrial
Control
Components
Industrial
Control
Components

339

AA
Company
Company
toto
Serve
Serve
Y
ve
A Company to Serve

10

e You
You
Where
Where
You
You
Are
Are
e You Where You Are

E-mail
E-mail
Address:info.OBD@delixi-electric.com
Address:info.OBD@delixi-electric.com
E-mail Address:info.OBD@delixi-electric.com
E-mail Address:Contact@himel-electric.com
11

Vous aimerez peut-être aussi