PT.

BERCA MANDIRI PERKASA

BP750
Open Type

SPECIFICATIONS ENGINE
Engine Model: KTA38-G2
Engine Speed: 1500RPM

BP750S

PRIME

.canopy Type

664kW

STANDBY

731kW

903HP

994HP

Type ................................................. In-Line, 4 cycle, waler cooled, Turbo


Charoed. aftercooled
Number of Cynder ..

...... 12

Boie x Stroke .................................... 159 x 159 mm


Displacement .....................

........ 37 .8 L

Compression Ratio ............................. 14,5 : 1


Fuel Injection Pump ............................ PT

Injection Pump

Governor ........................ .

Electrical Governor

..... EFC

Steady Speed Droop .......

*The above photo is for demonstration only. Reol product may look different.

GENSET OUTPUT

Lub. Oil Grade ................................... 15W40-CF4 Upgrade


Coolant Capacity ..... ...........

SO Hz

Frequency:

..... </= 1%

Lub. Oil Capacity ................................. 135 L

Voltage:

400VAC

Engine Speed:

lSOORPM

....... 252 L (Engine)

Cooling ..

.. Forced Water Cooling Cycle

Flywheel/Flywheel Housing .....

...... 18 I SAEO#

Dry Weight ........................ .

........4220 kg

Fuel Consumption at full load (prime) ....201 kglh

*Remark: Please consult your local supplier Jo, olher voltages

PRIME

STANDBY

600KW

660.W

750 KVA

825 KVA

BERCA POWER Genset


PERFORMANCE GUARANTEED
Standard series and Weather and Sound Proof Canopy series are designed, Manufactured
and tested under strict quaNty control procedure. to ensure top performance
at all times.

ALTERNATOR
Manufacturer: STAMFROD
Model: LV1634B
Control System ............... ..... .

Insulation Class .................................................Class H


Protection .

......... .IP23

Rated Power Factor

PACKAGED ACCESSORIES
Generator set units are packaged with anti-vibration system, advanced control panel,
starting system, synchronizing panel, base fuel tank and other accessories which make
ready for power station.
BASE SKID
Standard built-in anti-vibration system - bonded rubber units fitted as standard which
eliminate the need for rubber mats or spring mot.mUngs.

....................................0.8

StalorWinding ...... .

....... Double Layer Lap

Winding Pttch ....................

.................. 213

Winding Leads ................................................... 12


Waveform Distortion

........... No Load <1.5%

Telephone Interference ... ... .

................ THF < 2%

Maximum Overspeed

......... ..2250 rpm

Bearing .............................................................. Single


Weight ..............................................................1885 kg

COOLING SYSTEM
Set'""10Unt radiator for ambient temperature of 50C standard; Remote radiator with fan

motor or heal exchanger optional.

.................... SelfExcited

Voltage Regulation ..............................................+/- 0.5%

GENSET SPECIFICATIONS
Dimensions : 4500 x 1700 x 2360

mm (Open Type)

40GP Container (Canopy Type)

STAMFORD ALTERNATOR

Diy Weight : 8650 kg (Open Type)

10925 kg (Canopy Type)

APPLICATIONS
Alternators are designed to be suitable for typical generator applications, such as: backup,
standard production, ccrgeneration, rental, 1e'8comrnunications, etc.

Sound Level : 100dBA (Opeit Type)

74 dBA (Canopy Type)

Ambfent Temperature : 25.C


Altitude : 300 m
Relative Hurridity : Below 80%

STANDARD OF COMPLIANCE
Alternators conform to the main internalionalstandards and regulaUons:
IEC60034, NEMA MG1 :22, ISO 8528, CSA, CSA/UL, etc.
Alternators are designed, manufactured and marketed in an ISO 9001 environment.
TOP OFTHE RANGE ELECTRICAL PERFORMANCE
- Class H insulation
- Standard 12..,,.re re-ronnectable winding, 213 pitch, type number 6
High efficiency and motor starting capacity.
- Total harm:mic content <2.5%

CONDITIONS AND DEFINITIONS


Prime Power Rating:
Prime power rating_ is app~cable for unlimited number of operation hour per year in
variable load condition. Variable load should not exceed 70%of Prime Power in
average of total operation. A 10% overload isattowed for 1 hour in eveiy 12 hour of
consecutive operation.

Standby Power Rating:


Continuous running a1 varia~e k>ad for emergency power. No overload is allowed.

Standard referred:
Engine ratings are in accordance with IS03046 or BS5514.

Fuel Consumption:
Fuel consumption is defined under 100% Prime/Standby Rating.
Gensel Ratings:
Gen set is rated al 400VAC/50Hz.
Sound Level:
Sound level is measured at 7 m.

ST AND ARD I OPTIONAL SCOPE OF SUPPLY


GENSET

STANDARD

Cummins CCEC Diesel Engine


Electric Governor
Stamford AC AHernator
Mild Steel Skid Base
set Mount Anti-vibration Isolators
Control Panel and Main Breake

COOLING SYSTEM

STANDARD

Set Mount Radiator


Remote Radiator

OPTION

STANDARD

OPTION

DSE3110
DSE7220

ACCESSORIES

STANDARD

Industrial Silencer
Residential Silencer
Flexible Bellow

Maintenance Free Battery


Lead Acid Battery
Battery Float Charger
Block Heater

OPTION

Coolant Heater
Anti-<X>ndensation Heater

ELECTRICAL

STANDARD

3P MCCB and Breaker Panel


ATS Panel

OPTION

STANDARD

Base Fuel Tank


Dally Fuel Tank

The DSE3110 can be utilised as a Manual or Auto Start Module


for single gen-set applications and forms part of DSE's next
generation of control modules. The module has been designed
10 work with electronic and non electronic engines providing
advanced engine monitoring and protection features.
The DSE3110 Includes a backlit LCD display which clearly
shows the status of the engine at all trmes. The module
monitors engine speed, frequency, voltage and run hours and
also displays the wam1ng and shutdown status of the engine.
The module includes six digital inputs and four outputs. Two
of the outputs are configurable. The module can either be
programmed using the front panel or by using the DSE
Configuration Suite PC software.
The module is available In two variants: Magnetic Pick-up and
Can bus.
CAN - For 1Jse with CAN engines only. Optional frequency (Hz)
sensing from main AC alternator for gen-set applications.

MPU - For 1Jse WI.t h traditional (non-CAN) engines only.


Optional frequency (Hz) sensing from main AC alternator for
gen-set applications. Optional Magnetlc Pickup speed
sensing.

Parallel Panel

Fuel Tank

GENSET CONTROL MODULE DSE3110

OPTION

Heat Exchanger

CONTROL SYSTEM

OPTION

GENSET DIMENSIONS

BP750 Open Type Genset


Dry Weight:8650 KG
Size: 4500 x 1700 x 2360 mm
BP7 50S Canopy Type Genset
DryWeight:l0925 KG
Size:40 GP Container

The DSE7220 is an Auto Mains (Utility) Failure Control Module.


The DSE7220 includes the additional capability of being able to
monitor a mains (utility) supply. The module has been designed
to start and stop diesel and gas generating sets that Include
electronic and non-electronic engines.

PT. BERCA MANDIRI PERKASA


Jin. Pangeran Jayakarta 149A, Jakarta 10730- INDONESIA
Phone. +62 216006125,6399190, 6280900,
Fax. +62 21 6399191
Email. bmp@berca~mp.co.id
www.berca-mp.i;o.icf

Subsidiary of :

YOUR
TOTAL

PARTNER

PT. ALTR AK 1878

BRANCH NElWORKS:
ASEM REGES (021) 6281241 CIKARANG (021) 89901978 CK.EGON (0254) 390678 BANDUNG (022) 87523793 SEMARANG (024) 3544469 SURABAYA (031) 8471978 LAtll'UNG (0721) 789976 PALliMBANG (0711) 364453