Vous êtes sur la page 1sur 5

Syllabus HVAC:-

introduction to HVAC

Psychrometric Chart (York/Carrier Psych Analyser)

Kitchen Ventilation ( Hood Design)

Car Parking Ventilation (Jet Vent Fan Selection)

Toilet Ventilation (Residential & Commercial)

Heat Load Calculation(Manual/E-20 & Software_Carrier HAP)

Duct Designing Basics(types ,gauge selection ,low medium & high velocity systems)

Duct Designing Methods(Equal Friction, Velocity Reduction, Static Regain)

Duct Designing Software (McQuay Duct Sizer ,FDuctulator)

Duct Comparison and Fabrication Procedures

External Static Pressure(ESP) Calculation

Air Terminal Selection (Manual & Software-Beta Performance Data)

Reducer Selection

Refrigerant Pipe Sizing( Graphical method & Software)

VRV/VRF system designing (Manual & Software)

Coil Selection

Chilled Water Systems and Vapour Absorption Systems(VAMs)

Chiller Selection

Hydraulic Calculations( Manual & Software)

Primary & Secondary Pump Selection

Chilled Water Pipe Sizing(Manual & Software-McQuay Pipe Sizer)

Cooling Tower Selection

Stair Well Pressurization System

District Cooling System

Air Curtain Selection

Basic Concepts of Green Building Designing

Estimation and Costing

ASHRAE,SMACNA,NBC Standards

Plumbing (Water Supply/Drainage) Designing & Draughting


1)

Common Sanitary Fixtures Details : Standard trap pipe & discharge pipe sizes, Standard slopes for the
discharge pipes :

(a) Wash basin,

(b) Water closet

(c) Showers

(d) Sinks

(e) Bath tubs

(f) Bidets

(g) Urinals

(h) Floor drains (Floor Gullies)

Lay out of sanitary fixtures in toilets. Formula for flow through pipes :

(a) Darcy formula

(b) Chezys formula

(c) Manning formula

(d) Hazen formula

(e) Reynolds Number (Laminar / Turbulent Flow).

Water supply in building :

(a) Direct system.

(b) Pumped system.

Ground level (or) underground reservoir sizing.

Elevated roof tank (Storage cistern) sizing.

Pump selection (HP, Watts).

Water pipe sizing in Buildings.

Minimum number of smaller diameter water pipes that can be connected to bigger diameter pipes.
Plumbers chart for pipe sizing, Box formula.

Foul water drain in building stack, Branch drain/discharge pipe horizontal drain. Fixture unit rating,
Maximum number of discharge units allowed in stack, Single stack system, Design of horizontal drains by discharge
units method.

Septic tank, Soak away pits, Dispersion trenches designing.

Designing of Storm Water Drainage in buildings.

Auto pneumatic system, Pressure Tank Sizing.

External water supply for building. Garden water supply & fountain water pipe sizing, Calculation of
storage tank, Garden water fountain designing, Fountain pump selection.

Estimating Hot Water Demand, Heater Capacity selection.

Flush Water & Potable Water Loop sizing - (Software).

Designing of common appurtenances, Inspection chambers and Junction manholes.

Detailing of plumbing services & preparing plumbing drawing, Isometric Drawings.

Working drawings :

(a) Location maps

(b) Site plan

(c) Plan of roof

(d) Floor plan of the building

(e) Enlarged floor plan of toilets kitchens

Fire Fighting Designing & Draughting


1:

Introduction.

Classification of Fire.

Manual hand held Fire Cylinders Types, Using Procedure & General Maintenance Instructions.

Active & Passive Fire Protection System.

Stair well pressurization System.

Fire Water Sump Sizing, Over Head Tank Sizing.

Sprinklers Types, Selection, Designing, Pipe sizing.

Fire Hose Cabinets & Fire Hydrants Selection.

Fire Fighting Hydraulic Calculation, Head Loss & Pump head Calculations for High Rise Buildings.

Fire Water Pump [Main Pump, Jockey Pump & Diesel Pump] Classification, Types & Selection.

NFPA, NBC &FSAI Codes for Fire Fighting System Designing.

FM200 System Designing [Water Less Fire Protection system] Capacity, Pipe Sizing, Nozzle selection.

Fire Alarm System Designing.

Smoke Detector (Ionization Type, Optical).

Heat Detector, Linear Heat Detection Cable.

Flame Detector.

VESDA - Aspirating System.

Vous aimerez peut-être aussi