Reference Manual
2008 Datalogic Scanning, Inc.
820001970 (Rev. A)
01/08
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that
is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice. Datalogic is a registered trademark of
Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic
S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names
referred to herein are property of their respective owners.
CONTENTS
INTRODUCTION .......................................................................................... 1
INSTALLATION............................................................................................ 3
CONFIGURATION........................................................................................ 9
RS-232 PARAMETERS .............................................................................. 20
Baud Rate ................................................................................................... 21
Parity........................................................................................................... 22
Data Bits ..................................................................................................... 22
Stop Bits...................................................................................................... 23
Handshaking ............................................................................................... 23
Ack/Nack Protocol....................................................................................... 24
Fifo.............................................................................................................. 24
Inter-character Delay................................................................................... 25
Rx Timeout.................................................................................................. 25
Serial Trigger Lock ...................................................................................... 26
USB PARAMETERS .................................................................................. 27
Handshaking ............................................................................................... 28
Ack/Nack Protocol....................................................................................... 28
Fifo.............................................................................................................. 29
Inter-character Delay................................................................................... 29
Rx Timeout.................................................................................................. 30
Serial Trigger Lock ...................................................................................... 30
Keyboard Nationality ................................................................................... 31
Fifo.............................................................................................................. 32
Inter-character Delay................................................................................... 32
Inter-code Delay.......................................................................................... 33
Control Character Emulation....................................................................... 33
USB Keyboard Speed ................................................................................. 34
WEDGE PARAMETERS............................................................................. 35
Keyboard Nationality ................................................................................... 36
Caps Lock ................................................................................................... 37
Caps Lock Auto-Recognition (IBM AT compatible only)............................... 37
Num Lock.................................................................................................... 38
Inter-character Delay................................................................................... 38
Inter-code Delay.......................................................................................... 39
Keyboard Setting......................................................................................... 40
Control Character Emulation....................................................................... 42
iii
iv
GENERAL VIEW
QUICKSCAN MOBILE READERS
Reading Window
Trigger
Cradle
Charge completed
(yellow LED)
Charging
(red LED)
vi
INTRODUCTION
1 INTRODUCTION
The QuickScan family provides a valuable solution for users seeking an affordable
handheld device without compromise in performance.
The extensive range of models and options of this family can easily meet any specific
challenges required by retail, and commercial data collections applications.
The QuickScan Mobile is the ideal solution for retail and commercial environments
where continuous and multi-tasking activities are keys to optimum productivity, lower
cost of ownership and profitable business.
1.1
READING ANGLE
Successful scanning is obtained by tilting the reader with respect to the barcode to
avoid direct reflections, which could impair the reading performance. See the figures
below.
Successful reading is obtained by an audible tone.
Good read LED
OK
Not Advised
QUICKSCAN MOBILE
1.2
HANDS-FREE USE
When using the QuickScan Mobile on the cradle, remember to lock the reader by
pushing up the locking system as indicated in the following figure.
INSTALLATION
2 INSTALLATION
USING YOUR QUICKSCAN MOBILE READING SYSTEM
2.1
Follow the procedure below to start using your QuickScan Mobile reading system:
1. Connect a QuickScan Mobile cradle to the Host.
2. Insert the QuickScan Mobile reader into the cradle to start the battery charging.
A full charge of the Lithium battery takes 3.5 6 hours.
3.
4.
2.2
When inserting the new battery into the handle pay attention to
position the battery and the connector just as shown in Figure 3.
NOTE
Figure 1
Figure 2
Figure 3
QUICKSCAN MOBILE
4.
Insert the cover in the handle and screw it back into place.
Figure 4
WARNING
INSTALLATION
2.3
SYSTEM CONNECTIONS
You can connect the QuickScan Mobile cradle to the Host through the dedicated
connector, using the cable corresponding to the desired interface type.
1.
Connect the appropriate interface cable to the cradle by simply plugging it into
the Host connector on the base of the cradle.
Interface Cable
To disconnect the cable, insert a paper clip or other similar object into the hole
corresponding to the connector on the base of the cradle. Push down on the clip
while unplugging the cable. Refer to the following figure:
QUICKSCAN MOBILE
2.4
RS-232 CONNECTION
2.5
USB
2.6
CAB-413
2.7
INSTALLATION
CAB-431
POWER SUPPLY ADAPTER
2.8
CAB-445
CAB-446
2.9
CAB-431
POWER SUPPLY ADAPTER
QUICKSCAN MOBILE
2.10
CONFIGURATION
3 CONFIGURATION
3.1
CONFIGURATION METHODS
3.1.1
This manual can be used for complete setup and configuration of your reader by
following the setup procedures in this chapter.
If you wish to change the default settings, this manual provides complete
configuration of your reader in an easy way.
To configure your reader:
1.
Open the folded page in Appendix C with the hex-numeric table and keep it open
during the device configuration.
2.
Read the Enter Configuration code ONCE, available at the top of each page of
configuration.
3.
Modify the desired parameters in one or more sections following the procedures
given for each group.
4.
Read the Exit and Save Configuration code ONCE, available at the top of each
page of configuration.
Reference notes describing the operation of the more complex parameters are given
in chapter 4.
3.1.2
Datalogic Aladdin
3.1.3
Copy Command
A previously configured device (Master), can be used to send its configuration directly to
other devices of the same type (Slaves). The particular procedure for each device is
given.
QUICKSCAN MOBILE
3.1.4
3.2
1.
2.
Read the codes below to set the radio address of the QuickScan Mobile
reader.
$+$*o
Enter configuration
$+;
3.
RA0RFH
+
four digits for the QuickScan Mobile Address (from 0000 to 1999).
All readers used in the same area must have different addresses.
4.
5.
Read the Bind code to pair the QuickScan Mobile to the cradle.
The reader is dedicated to the cradle. Any previously bound reader will be
excluded.
$-?
Bind
$+RN0$-I
The yellow LED on the QuickScan Mobile will blink; the reader is ready to be
positioned onto the cradle.
10
CONFIGURATION
6.
Firmly position the reader onto the cradle within 10 seconds, a beep will be
emitted, signaling that the cradle has been paired to the QuickScan Mobile,
and the yellow LED on the reader will go off.
Yellow LED
7.
$+RX0$-q
Go to par. 3.3 Interface Selection.
11
QUICKSCAN MOBILE
3.3
INTERFACE SELECTION
$+CP0$-$
POS Terminals
Nixdorf Mode A
$+CM2EC0$->
Fujitsu
$+CM1$-
ICL Mode
$+CM0$-
For POS terminal default settings refer to par. 4.9.
PEN
$+CP6$-B
12
CONFIGURATION
$+CP500$-a
IBM XT
$+CP503$-v
PC Notebook
$+CP505$-
IBM SURE1
$+CP506$-$
$+CP504$-}
13
QUICKSCAN MOBILE
WEDGE (CONTINUED)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the correct KEY
TRANSMISSION code. Select the KEYBOARD TYPE if necessary
(default = advanced keyboard).
make-only keyboard
$+CP502$-o
make-break keyboard
$+CP501$-h
KEYBOARD TYPE
advanced keyboard
$+FK1$-
typewriter keyboard
$+FK0$-
14
CONFIGURATION
WEDGE (CONTINUED)
ALT MODE
The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly
independently from the Keyboard Nationality used. You do not need to make a
Keyboard Nationality selection.
(default = Num Lock Unchanged). Make sure the Num Lock key on your
keyboard is ON.
IBM AT - ALT mode
$+CP507$-+
PC Notebook - ALT mode
$+CP508$-2
WYSE TERMINALS
ANSI Keyboard
$+CP509$-9
PC Keyboard
$+CP510$-g
ASCII Keyboard
$+CP511$-n
VT220 style Keyboard
$+CP514$-
15
QUICKSCAN MOBILE
WEDGE (CONTINUED)
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
$+CP512$-u
IBM 46XX (only for Quickscan M2 Type:110)
PORT 9B
4501 Protocol
$+CP800$-p
(typical)
1520 Protocol
$+CP801$-w
PORT 5B
1520 Protocol
$+CP801$-w
(typical)
4501 Protocol
$+CP800$-p
16
CONFIGURATION
3.4
USB Start-up
As with all USB devices, upon connection, the Host performs several checks by
communicating with the QuickScan Mobile. During this phase the yellow LED on the
QuickScan Mobile reader blinks and normal operations are suspended. Two basic
conditions must be met before the QuickScan Mobile is ready to read codes, the
correct USB driver must be loaded and sufficient power must be supplied to the
reader.
First Start-Up
For all systems, the correct USB driver for the default
USB-KBD interface is included in the Host Operating
System and will either be loaded automatically or will
be suggested by the O.S. and should therefore be
selected from the dialog box (the first time only).
Normally the Host supplies sufficient power to the
reader, the start-up phase ends correctly, the yellow
LED stops blinking.
In rare cases, if the Host does not supply sufficient
power to the reader, a dialog box will appear on the
Host and the reader will be blocked (yellow LED
continues blinking). In this case, disconnect the USB
device cable at the Host (yellow LED stops blinking);
and then try a different USB port as indicated by the
Operating System message. You can now read
codes.
Connect QuickScan
Mobile to Host
Load drivers
(if requested)
Read test codes.
Reader is READY
17
QUICKSCAN MOBILE
USB
USB-KBD
$+UA03$-:
USB-KBD-ALT-MODE
$+UA04$-@
USB-KBD-APPLE
$+UA05$-F
USB-COM*
$+UA02$-4
USB-IBM-Table Top
$+UA00$-(
USB-IBM-Hand Held
$+UA01$-.
*
18
When configuring USB-COM, the relevant files and drivers must be installed from
the USB Device Installation software, which can be downloaded from the web site
http://www.scanning.datalogic.com.
CONFIGURATION
3.5
Once your reader is setup, you can change the default parameters to meet your
application needs. Refer to the preceding paragraphs for initial configuration in order
to set the default values and select the interface for your application.
In this manual, the configuration parameters are divided into logical groups making it
easy to find the desired function based on its reference group.
The first five groups are for Standard/IBM Interface parameter configuration:
RS-232
USB
WEDGE (only for Quickscan M2 type:130)
PEN EMULATION
IBM 46xx (only for Quickscan M2 type:110)
The following parameter groups are common to all interface applications:
DATA FORMAT parameters regard the messages sent to the Host system for all
interfaces except Pen Emulation.
READING PARAMETERS control various operating modes and indicator status
functioning.
DECODING PARAMETERS maintain correct barcode decoding in certain special
reading conditions.
CODE SELECTION parameters allow configuration of a personalized mix of codes,
code families and their options.
ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced
formatting of messages towards the Host. It cannot be used with Pen Emulation
connections.
RADIO PARAMETERS (Mobile series only) allow configuration of radio control
parameters.
19
RS-232 PARAMETERS
~
~
~
~
~
~
~
~
~
~
BAUD RATE
PARITY
DATA BITS
STOP BITS
HANDSHAKING
ACK/NACK PROTOCOL
FIFO
INTER-CHARACTER DELAY
RX TIMEOUT
SERIAL TRIGGER LOCK
~
~
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
20
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
Enter Configuration
$+;
RS-232
$-?
BAUD RATE
300 baud
CD1X
600 baud
CD2[
1200 baud
CD3^
2400 baud
CD4a
4800 baud
CD5d
9600 baud
CD6g
19200 baud
CD7j
38400 baud
CD8m
21
Enter Configuration
$+;
RS-232
PARITY
none
CC0S
even parity
CC1V
odd parity
CC2Y
DATA BITS
7 bits
CA0O
8 bits
CA1R
9 bits
CA2U
22
$-?
Enter Configuration
$+;
RS-232
$-?
STOP BITS
1 stop bit
CB0Q
2 stop bits
CB1T
HANDSHAKING
disable
CE0W
hardware (RTS/CTS)
CE1Z
software (XON/XOFF)
CE2]
RTS always ON
CE3`
See par. 4.1.1 for details.
23
Enter Configuration
$+;
RS-232
$-?
ACK/NACK PROTOCOL
disable
ER0s
enable
ER1v
See par. 4.1.2 for details, particularly on implementing this parameter with QuickScan Mobile.
FIFO
disable
EC0U
enable
EC1X
See par. 4.1.3 for details.
24
Enter Configuration
$+;
RS-232
$-?
INTER-CHARACTER DELAY
CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
RX TIMEOUT
CL5
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds
25
Enter Configuration
$+;
RS-232
$-?
disabled
CR0q
CR1t
Read 2 characters from the Hex/Numeric table in the range 00-FE where:
26
USB PARAMETERS
~
USB-COM
Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx
timeout, Serial trigger lock
~
USB-KBD
Keyboard nationality, FIFO, Inter-character delay, Inter-code
delay, Control character emulation, USB keyboard speed
~
USB-IBM
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
27
Enter Configuration
$+;
USB-COM
HANDSHAKING
disable
CE0W
hardware (RTS/CTS)
CE1Z
software (XON/XOFF)
CE2]
RTS always ON
CE3`
See par. 4.1.1 for details.
ACK/NACK PROTOCOL
disable
ER0s
enable
ER1v
See par. 4.1.2 for details.
28
$-?
Enter Configuration
$+;
USB-COM
$-?
FIFO
disable
EC0U
enable
EC1X
See par. 4.1.3 for details.
INTER-CHARACTER DELAY
CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
29
Enter Configuration
$+;
USB-COM
$-?
RX TIMEOUT
CL5
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds
disabled
CR0q
enable and select characters
CR1t
Read 2 characters from the Hex/Numeric table in the range 00-FE where:
30
Enter Configuration
$+;
USB-KBD
$-?
KEYBOARD NATIONALITY
Not Available for USB-KBD-ALT-MODE Interface
This parameter default value is restored through the Interface Selection code and not Restore
Default.
Belgian
FJ7y
English
FJ4p
French
FJ2j
German
FJ3m
Italian
FJ1g
Japanese
FJ8|
Spanish
FJ6v
Swedish
FJ5s
USA
FJ0d
31
Enter Configuration
$+;
USB-KBD
FIFO
disable
EC0U
enable
EC1X
See par. 4.1.3 for details.
INTER-CHARACTER DELAY
CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
32
$-?
Enter Configuration
$+;
USB-KBD
$-?
INTER-CODE DELAY
FG.
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled
FO0n
CTRL + Key
FO1q
33
Enter Configuration
$+;
USB-KBD
Normal
UT10c
Fast
UT01d
34
$-?
WEDGE PARAMETERS
~
~
~
~
~
~
~
~
KEYBOARD NATIONALITY
CAPS LOCK
CAPS LOCK
AUTO-RECOGNITION
NUM LOCK
INTER-CHARACTER DELAY
INTER-CODE DELAY
KEYBOARD SETTING
CONTROL CHARACTER
EMULATION
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
35
Enter Configuration
$+;
WEDGE
$-?
KEYBOARD NATIONALITY
Belgian
FJ7y
English
FJ4p
French
FJ2j
German
FJ3m
Italian
FJ1g
Spanish
FJ6v
Swedish
FJ5s
USA
FJ0d
The Japanese Keyboard Nationality selection is valid only for IBM AT compatible PCs.
Japanese
FJ8|
36
Enter Configuration
$+;
WEDGE
$-?
CAPS LOCK
FE0Z
caps lock ON
FE1]
Select the appropriate code to match your keyboard caps lock status.
Note:
disable
FP0p
enable
FP1s
37
Enter Configuration
$+;
WEDGE
$-?
NUM LOCK
FL1k
FL0h
This selection is used together with the Alt Mode interface selection for AT or Notebook PCs.
It changes the way the Alt Mode procedure is executed; therefore it should be set as follows:
if your keyboard Num Lock is normally off use toggle num lock
In this way the device will execute the Alt Mode procedure correctly for your application.
INTER-CHARACTER DELAY
CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
38
Enter Configuration
$+;
WEDGE
$-?
INTER-CODE DELAY
FG.
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled
39
Enter Configuration
$+;
WEDGE
$-?
KEYBOARD SETTING
ALPHANUMERIC KEYBOARD SETTING
The reader can be used with terminals or PCs with various keyboard types and nationalities
through a simple keyboard setting procedure.
The type of computer or terminal must be selected before activating the keyboard setting
command.
Keyboard setting consists of communicating to the reader how to send data corresponding to
the keyboard used in the application. The keys must be set in a specific order.
Press and release a key to set it.
Some characters may require more than one key pressed simultaneously during normal use
(refer to the manual of your PC or terminal for keyboard use). The exact sequence must be
indicated to the reader in this case pressing and releasing the different keys.
Example:
If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the
character "$" to the video, to set the "$", press and release "Shift" then press and release "4".
Each pressed and released key must generate an acoustic signal on the reader, otherwise
repress the key. Never press more than one key at the same time, even if this corresponds to
the normal use of your keyboard.
Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps.
Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting
procedure. "SHIFT" must be repressed for each character and cannot be substituted by
"CAPS LOCK".
setting the alphanumeric keyboard
FB0T
Read the code above.
Press the keys shown in the following table according to their numerical order.
Some ASCII characters may be missing as this depends on the type of keyboard: these are
generally particular characters relative to the various national symbologies. In this case:
The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with
keys not used, or substituted with each other.
characters can be substituted with other single symbols (e.g. "SPACE") even if not
included in the barcode set used.
The reader signals the end of the procedure with 2 beeps indicating the keys have
been registered.
40
WEDGE
01 : Shift
02 : Alt
03 : Ctrl
04 : Backspace
05 : SPACE
06 : !
07 : "
08 : #
09 : $
10 : %
11 : &
12 : '
13 : (
14 : )
15 : *
16 : +
17 : ,
18 : 19 : .
20 : /
21 : 0
22 : 1
23 : 2
24 : 3
25 : 4
26 : 5
27 : 6
28 : 7
29 : 8
30 : 9
31 : :
32 : ;
33 : <
34 : =
35 : >
36 : ?
37 : @
38 : A
39 : B
40 : C
41 : D
42 : E
43 : F
44 : G
45 : H
46 : I
47 : J
48 : K
49 : L
50 : M
51 : N
52 : O
53 : P
54 : Q
55 : R
56 : S
57 : T
58 : U
59 : V
60 : W
61 : X
62 : Y
63 : Z
64 : [
65 : \
66 : ]
67 : ^
68 : _ (underscore)
69 : `
70 : {
71 : |
72 : }
73 : ~
74 : DEL
The keyboard setup functioning is signaled by the LEDs on the cradle. Each key stroke
corresponds to a double blinking of the yellow LED.
By pressing the Backspace key the red LED on the cradle blinks, while the yellow LED stays on.
Do not place the reader onto the cradle during this procedure. Otherwise,
the battery charging will occur modifying the LEDs functioning.
CAUTION
Once the procedure has been completed, the yellow LED turns off.
41
Enter Configuration
$+;
WEDGE
FO0n
CTRL + Key
FO1q
42
$-?
PEN EMULATION
~
~
~
~
~
~
~
OPERATING MODE
MINIMUM OUTPUT PULSE
CONVERSION TO CODE 39
OVERFLOW
OUTPUT LEVEL
IDLE LEVEL
INTER-BLOCK DELAY
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
43
PEN EMULATION
The operating mode parameters are complete commands and do not require reading the
Enter and Exit configuration codes.
OPERATING MODE
interpret mode
$]8
Interprets commands without sending them to the decoder.
transparent mode
$[4
Sends commands to the decoder without interpreting them.
44
Enter Configuration
$+;
PEN EMULATION
$-?
200 s
DG0\
400 s
DG1_
600 s
DG2b
800 s
DG3e
1 ms
DG4h
1.2 ms
low resolution code
emulation
DG5k
45
Enter Configuration
$+;
PEN EMULATION
DA0P
Transmits codes in their original format.
DA1S
Converts codes read into Code 39 format.
DA2V
Converts codes read into Code 128 format.
46
$-?
Enter Configuration
$+;
PEN EMULATION
$-?
OVERFLOW
narrow
DH0^
medium
DH1a
wide
DH2d
See par. 4.2.3 for details.
OUTPUT LEVEL
normal
(white = logic level 0)
DD0V
inverted
(white = logic level 1)
DD1Y
See par. 4.2.4 for details.
47
Enter Configuration
$+;
PEN EMULATION
IDLE LEVEL
normal
(black level)
DE0X
inverted
(white level)
DE1[
See par. 4.2.4 for details.
INTER-BLOCK DELAY
CK3
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from .1 to 9.9 seconds
delay disabled
48
$-?
IBM 46XX
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
49
Enter Configuration
$+;
IBM 46xx
conversion to Code 39
GD0Y
IBM Standard
GD1\
mixed IBM Standard + Code 39
GD2_
Cradle check the Host command
GE0[
Cradle ignore Host command
GE1^
See par. 4.3.1 for details.
50
$-?
DATA FORMAT
NOT FOR PEN INTERFACES
~
~
~
~
~
~
~
~
~
~
~
CODE IDENTIFIER
CUSTOM CODE IDENTIFIER
HEADER
TERMINATOR
SPECIAL KEYS
FIELD ADJUSTMENT
FIELD ADJ. CHARACTER
CODE LENGTH TX
CHARACTER REPLACEMENT
ADDRESS STAMPING
ADDRESS DELIMITER
~
~
~
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
51
DATA FORMAT
ISBT 128
Code 93
CIP/39
CIP/HR
Code 32
MSI
Plessey Standard
Plessey Anker
Telepen
Delta IBM
Code 11
Code 16K
Code 49
RSS Expanded Linear and Stacked
RSS Limited
RSS 14 Linear and Stacked
52
AIM STANDARD
DATALOGIC STANDARD
]Iy
]Xy
]Sy
]Xy
]E4
]E0
]Xy
]Xy
]E5
]E6
]E1
]E2
]Xy
]Xy
]Xy
]Xy
]Ay
]Ay
]Fy
]Xy
]Cy
]Cy
] C4
]Gy
]Xy
]Xy
]Xy
]My
]P0
]P1
]X0
]X0
]Hy
]K0
]Ty
]e0
]e0
]e0
N
P
O
Q
A
B
C
D
J
K
L
M
F
G
H
I
V
W
R
S
T
k
f
U
Y
e
X
Z
a
o
d
c
b
p
q
t
v
u
Custom
DATA FORMAT
AIM standard identifiers are not defined for all codes: the X identifier is assigned to the
code for which the standard is not defined. The y value depends on the selected options
(check digit tested or not, check digit tx or not, etc.).
When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can
be defined for each code type. If only 1 identifier character is required, the second
character must be selected as FF (disabled).
The code identifier can be singly disabled for any code by simply selecting FF as the first
identifier character.
Write in the Custom character identifiers in the table above for your records.
53
Enter Configuration
$+;
DATA FORMAT
CODE IDENTIFIER
disable
EB0S
Datalogic standard
EB1V
AIM standard
EB2Y
custom
EB3\
54
$-?
Enter Configuration
$+;
$-?
DATA FORMAT
EH/
Select the code type from the code table in Appendix B for the identifier you want to
change.
e You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is
required, the second character must be selected as FF (disabled). Read the hexadecimal
value corresponding to the character(s) you want to define as identifiers for the code
selected in step d: valid characters are in the range 00-FD. For Wedge and USB-KBD
interfaces, it is also possible to read the Special Key(s) on page 58.
Example:
Read
EH/
Code 39
VW
40
FF
55
Enter Configuration
$+;
$-?
DATA FORMAT
HEADER
no header
EA00*
one character header
EA01.
two character header
EA022
three character header
EA036
four character header
EA04:
five character header
EA05>
six character header
EA06B
seven character header
EA07F
eight character header
EA08J
After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters
are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s)
on page 58.
Example:
four character header
+ 41 + 42 + 43 + 44 = Header ABCD
For more details see par. 4.4.1.
56
Enter Configuration
$+;
$-?
DATA FORMAT
TERMINATOR
no terminator
EA10-
one character terminator
EA111
two character
terminator
EA125
three character terminator
EA139
four character
terminator
EA14=
five character terminator
EA15A
six character terminator
EA16E
seven character terminator
EA17I
eight character
terminator
EA18M
After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters
are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s)
on page 58.
Example:
two character terminator
+ 0D + 0A = Terminator CR LF
For more details see par. 4.4.1.
57
Enter Configuration
$+;
DATA FORMAT
$-?
SPECIAL KEYS
Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces
Select one or more of the following Special Keys according to your needs.
Special Key 1
9C
Special Key 2
9D
Special Key 3
9E
Special Key 4
9F
Special Key 5
A0b
58
Enter Configuration
$+;
$-?
DATA FORMAT
FIELD ADJUSTMENT
disable field adjustment
EF0[
Field adjustment allows a number of characters n, to be added to or subtracted from the
barcode read. The adjustment can be different for each enabled code type. To define the field
adjustment:
EF+
d Select the code type from the Code Identifier Table in Appendix B.
e Select the type of adjustment to perform:
right addition
01
left addition
12
right deletion
23
left deletion
34
f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many
characters to add or delete:
Conditions:
Adjustment is only performed on the barcode data; the Code Identifier and Code Length
Transmission fields are not modified by the field adjustment parameter.
If the field setting would subtract more characters than exist in the barcode, the subtraction
will take place only to code length 0.
You can set up to a maximum of 10 different field adjustments on the same barcode family
or on different barcode families.
Read
EF+
Code 39
VW
right addition
01
04
59
Enter Configuration
$+;
DATA FORMAT
$-?
EG-
d Read the hexadecimal value corresponding to the character you want to use for field
adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it
is also possible to read the Special Key(s) on page 58.
Example:
To define the field adjustment character = A:
field adjustment character
Read
+ 41
CODE LENGTH TX
code length not transmitted
EE0Y
code length transmitted in variable-digit format
EE1\
code length transmitted in fixed 4-digit format
EE2_
The code length is transmitted in the message after the Headers and Code Identifier characters.
The code length is calculated after performing any field adjustment operations.
60
Enter Configuration
$+;
DATA FORMAT
$-?
CHARACTER REPLACEMENT
disable character replacement
EO0m
This parameter allows up to three characters to be replaced from the barcode read. These
substitutions are stored in memory. To define each character replacement:
EO1p
second character replacement
EO2s
third character replacement
EO3v
d
From the Code Identifier Table in Appendix B, read the Code Identifier for the desired
code family.
0 = character replacement will be effective for all code families.
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)
which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is
also possible to read the Special Key(s) on page 58.
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE)
which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is
also possible to read the Special Key(s) on page 58.
FF = the character to be replaced will be substituted with no character, that is, it will be
removed from the code.
61
Example:
The following strings define:
1.
2.
Code 39
EO1p + VW +
30
31
For Code 39 codes containing the string "0123", the contents transmitted will be "1123".
second character
replacement
Code 39
EO2s + VW +
41
42
For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".
62
Enter Configuration
$+;
DATA FORMAT
$-?
ADDRESS STAMPING
disable reader address stamping
RU0
enable reader address stamping
RU1"
See par. 4.4.3 for details.
ADDRESS DELIMITER
disable reader address delimiter
RV0!
enable reader address delimiter and select characters
RV1$
Read 2 HEX characters in the range 00-FE.
63
READING PARAMETERS
~
~
~
~
~
~
~
~
~
~
~
~
HAND-HELD OPERATION
STAND OPERATION
HARDWARE TRIGGER MODE
TRIGGER-OFF TIMEOUT
FLASH MODE
READS PER CYCLE
SAFETY TIME
BEEPER INTENSITY
BEEPER TONE
BEEPER TYPE
BEEPER LENGTH
STAND RECOGNITION BEEP
~
~
~
~
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
64
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
Enter Configuration
$+;
READING PARAMETERS
$-?
HAND-HELD OPERATION
hardware trigger
BK1e
software trigger
BK0b
* always on
BK3k
* not available for Mobile series readers
automatic
BK2h
hardware trigger ready
BK4n
STAND OPERATION
ONLY Devices with Stand Recognition Beep
hardware trigger
BU3
software trigger
BU1y
* always on
BU2|
* not available for Mobile series readers
automatic
BU0v
65
Enter Configuration
$+;
READING PARAMETERS
$-?
BA0N
trigger active pulse
BA1Q
See par. 4.5.1 for details
TRIGGER-OFF TIMEOUT
trigger-off timeout
BD$
Read 2 numbers in the range 00-99:
00 = disables the trigger-off timeout
01-99 = corresponds to a max. 99-sec. delay after the trigger
press to allow the reader to turn off automatically.
trigger-off timeout disabled
66
Enter Configuration
$+;
READING PARAMETERS
$-?
FLASH MODE
"FLASH" ON duration
BB0P
"FLASH" OFF duration
BB1S
Read 2 numbers in the range 01-99:
01 to 99 = from .1 to 9.9 seconds.
Flash-ON = 1 sec. Flash-OFF = 0.6 sec
BC0R
multiple reads per cycle
BC1U
See par. 4.5.3 for details.
67
Enter Configuration
$+;
READING PARAMETERS
$-?
SAFETY TIME
safety time
BE&
Limits same code consecutive reading.
BEEPER INTENSITY
* very low intensity
BG0Z
low intensity
BG1]
medium intensity
BG2`
high intensity
BG3c
*
68
This sets the beeper OFF for data entry, while for all other beeper signals it has the
meaning very low intensity. The Beeper Intensity parameter is effective for all operating
conditions described in par. 5.2.
Enter Configuration
$+;
READING PARAMETERS
$-?
BEEPER TONE
tone 1
BH0\
tone 2
BH1_
tone 3
BH2b
tone 4
BH3e
BEEPER TYPE
monotone
BJ0`
bitonal
BJ1c
BEEPER LENGTH
long
BI0^
short
BI1a
69
Enter Configuration
$+;
READING PARAMETERS
$-?
disable
BV0x
enable
BV1{
70
DECODING PARAMETERS
~
~
~
~
~
INK SPREAD
OVERFLOW CONTROL
INTERDIGIT CONTROL
DECODING SAFETY
PUZZLE SOLVER
~
~
~
~
~
1.
2.
3.
Read the Enter Configuration code ONCE, available at the top of each page.
Read configuration codes from the desired groups.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
71
Enter Configuration
$+;
DECODING PARAMETERS
INK SPREAD
disable
AX0{
enable
AX1~
See par. 4.6.1 for details.
OVERFLOW CONTROL
disable
AW1|
enable
AW0y
See par. 4.6.2 for details.
72
$-?
Enter Configuration
$+;
$-?
DECODING PARAMETERS
INTERDIGIT CONTROL
disable
AV0w
enable
AV1z
See par. 4.6.3 for details.
DECODING SAFETY
one read
ED0W
(decoding safety disabled)
two reads
ED1Z
three reads
ED2]
four reads
ED3`
Required number of good reads before accepting code.
73
Enter Configuration
$+;
DECODING PARAMETERS
$-?
PUZZLE SOLVER
disable
AU0u
enable
AU1x
In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of
the single code to reconstruct it.
To read codes using this technology, simply move the illuminated bar over the code so that
each line of the code is scanned. During this process a series of brief ticks indicates that
reading is proceeding correctly.
Conditions:
EAN 13
without Add-on
Code 128
Code 39
74
UPC A
without Add-on
CODE SELECTION
~
~
~
~
~
~
~
~
~
~
~
~
~
~
EAN/UPC FAMILY
2/5 FAMILY
CODE 39 FAMILY
CODE 128 FAMILY
CODABAR FAMILY
CODE 93
MSI
PLESSEY
TELEPEN
DELTA IBM
CODE 11
CODE 16K
CODE 49
GS1 DATABAR
~
~
~
~
~
~
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
75
Enter Configuration
$+;
CODE SELECTION
$-?
AZ0
The reader allows up to 5 code selections. This does not limit the
number of CODES enabled to 5, as it depends on the code family.
NOTE
SINGLE
SELECTIONS =
Example
5 code selections:
1. 2/5 Interleaved
2. 2/5 Industrial
3. Code 128 + EAN 128
4. Code 39 Full ASCII + Code 32
5. UPC A/UPC E
In this section all SINGLE code selections are underlined and in bold.
76
Enter Configuration
$+;
CODE SELECTION
$-?
EAN/UPC FAMILY
AA0M
c Read the desired family code
Note:
Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable
another selection, first disable the family.
WITHOUT ADD ON
AA1P
EAN 8/EAN 13
AA3V
UPC A/UPC E
AA4Y
77
Enter Configuration
$+;
$-?
CODE SELECTION
WITH ADD ON 2 AND 5
AA5\
EAN 8/EAN 13
AA6_
UPC A/UPC E
AA7b
WITH ADD ON 2 ONLY
EAN 8/EAN 13
AAK7
UPC A/UPC E
AAM=
WITH ADD ON 5 ONLY
EAN 8/EAN 13
AAL:
UPC A/UPC E
AAN@
78
Enter Configuration
$+;
CODE SELECTION
$-?
AA8Ad03
EAN/UPC Autodiscrimination ADD ON by
Prefix
AA8Ad19
By setting the EAN/UPC Autodiscrimination ADD ON by Prefix, the desired prefixes
must be selected by reading the corresponding codes given in the following section,
since no prefix is configured by default.
79
Enter Configuration
$+;
$-?
CODE SELECTION
SELECT EAN/UPC PREFIXES
NOTE
ET0w
OR
select one or more of the following prefixes:
378/379
ET1378ET2379P
434/439
ET3434ET4439
414/419
ET5414ET6419}
977
ET7977Q
978
ET8978Z
979
ET9979c
The commands above are not mutually exclusive. They can be used to configure
more than one set of prefixes simultaneously.
80
Enter Configuration
$+;
CODE SELECTION
$-?
Example:
The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the
434/439, 977 and 978 prefixes:
1.
2.
434/439: enables reading and transmission with ADD ON of all EAN/UPC barcodes
starting with 434/439 prefixes.
3.
977: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting
with 977 prefix.
4.
978: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting
with 978 prefix.
EAN/UPC Autodiscrimination ADD ON by
Prefix
AA8Ad19
434/439
ET3434ET4439
977
ET7977Q
978
ET8978Z
ET0w
81
Enter Configuration
$+;
$-?
CODE SELECTION
EAN/UPC CHECK DIGIT TX SELECTIONS
For each code type in this family you can choose to transmit the check digit or not
CHECK DIGIT TRANSMISSION
NO CHECK DIGIT
TRANSMISSION
EAN 8
AAG1o
EAN 8
AAG0k
EAN 13
AAH1r
EAN 13
AAH0n
UPC A
AAI1u
UPC A
AAI0q
UPC E
AAJ1x
UPC E
AAJ0t
82
Enter Configuration
$+;
CODE SELECTION
$-?
CONVERSION OPTIONS
AAA
UPC E to EAN 13 conversion
AAB
UPC A to EAN 13 conversion
AAC
EAN 8 to EAN 13 conversion
AAD"
Enable only ISBN conversion
AP1n
Enable only ISSN conversion
AP2q
Enable both ISBN and ISSN conversion
AP3t
Disable both ISBN and ISSN conversion
AP0k
83
Enter Configuration
$+;
$-?
CODE SELECTION
2/5 FAMILY
disable the family
AC0Q
c Read the desired family code
Interleaved 2/5
AC1T
12
Normal 2/5 (5 Bars)
AC2W
check digit control and transmission
23
Industrial 2/5 (IATA)
AC3Z
check digit control without transmission
34
Matrix 2/5 (3 Bars)
AC4]
AC5`
French pharmaceutical code
84
where:
First 2 digits = minimum code length.
Second 2 digits = maximum code
length.
The maximum
characters.
code
length
is
99
Enter Configuration
$+;
CODE SELECTION
$-?
CODE 39 FAMILY
AB0O
Standard Code 39
AB1R
AB2U
12
23
34
85
Enter Configuration
$+;
CODE SELECTION
$-?
The pharmaceutical codes below are part of the Code 39 family but have no check digit
selections.
Code CIP39
AB3X
French pharmaceutical code
Code 32
AB4[
Italian pharmaceutical code
AB*=
86
Enter Configuration
$+;
CODE SELECTION
$-?
AI0]
c Read the desired family code
Code 128
AI11=
control without transmission
of check digit
EAN 128
AI21@
control without transmission
of check digit
EQ0q
enable
EQ1t
If the <GS> character has been modified in the Character Replacement parameter, the new
character is affected by this command.
87
Enter Configuration
$+;
CODE SELECTION
$-?
ISBT 128
AI31C
Enabling ISBT 128 automatically disables Puzzle Solver.
AILJ
The maximum code length is 99 characters. The minimum code length must always be less
than or equal to the maximum.
Examples:
0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only.
CODE 93
AK0a
Code 93
AK1d
control without transmission
of check digit
88
Enter Configuration
$+;
$-?
CODE SELECTION
CODABAR FAMILY
AD0S
c Read the desired equality control code
Standard Codabar
AD113
no start/stop character equality
control
no transmission
12
Standard Codabar
AD127
start/stop character equality
control
transmission
23
The Codabar ABC code below uses a fixed start/stop character transmission selection.
Codabar ABC
AD212)
no start/stop character equality control but transmission.
89
Enter Configuration
$+;
$-?
CODE SELECTION
Codabar ABC Forced Concatenation
enable Codabar ABC with forced concatenation
AD2321
non start/stop character equality control but transmission
AD*A
The start/stop character case selections below are valid for the entire Codabar family:
ADA0_
transmit start/stop characters in upper case
ADA1c
90
Enter Configuration
$+;
CODE SELECTION
$-?
MSI
disable the family
AE0U
Enable the code by selecting one of the check digit selections.
no check digit control
AE1X
MOD10 check digit control
no check digit transmission
AE2[
MOD10 check digit control
check digit transmission
AE3^
MOD11 - MOD10 check digit control
no check digit transmission
AE4a
MOD11 - MOD10 check digit control
check digit transmission
AE5d
MOD10 - MOD10 check digit control
no check digit transmission
AE6g
MOD10 - MOD10 check digit control
check digit transmission
AE7j
91
Enter Configuration
$+;
CODE SELECTION
$-?
PLESSEY
disable the family
AF0W
Enable the code by selecting one of the check digit selections.
Standard Plessey
no check digit control
AF117
check digit control
check digit transmitted
AF12;
check digit control
check digit not transmitted
AF13?
Anker Plessey
no check digit control
AF21:
check digit control
check digit transmitted
AF22>
check digit control
check digit not transmitted
AF23B
92
Enter Configuration
$+;
CODE SELECTION
$-?
TELEPEN
disable the family
AL0c
Enable the code by selecting one of the check digit selections.
Numeric Telepen
no check digit control
AL11C
check digit control
check digit transmitted
AL12G
check digit control
check digit not transmitted
AL13K
Alphanumeric Telepen
no check digit control
AL21F
check digit control
check digit transmitted
AL22J
check digit control
check digit not transmitted
AL23N
93
Enter Configuration
$+;
CODE SELECTION
DELTA IBM
disable the family
AH0[
Enable the code by selecting one of the check digit selections.
AH1^
AH2a
AH3d
94
$-?
Enter Configuration
$+;
CODE SELECTION
$-?
CODE 11
disable the family
AG0Y
Enable the code by selecting one of the check digit selections.
no check digit control
AG1\
Type C check digit control
check digit transmitted
AG21<
Type C check digit control
check digit not transmitted
AG22@
Type K check digit control
check digit transmitted
AG31?
Type K check digit control
check digit not transmitted
AG32C
Type C and Type K
check digit control
check digits transmitted
AG41B
Type C and Type K
check digit control
check digits not transmitted
AG42F
95
Enter Configuration
$+;
CODE SELECTION
$-?
CODE 16K
AJ0_
Code 16K
AJ1b
To read stacked codes, simply move the reader over the code so that each line of the code is
scanned. During this process a series of brief ticks indicates that reading is proceeding
correctly.
CODE 49
AM0e
Code 49
AM1h
To read stacked codes, simply move the reader over the code so that each line of the code is
scanned. During this process a series of brief ticks indicates that reading is proceeding
correctly.
96
Enter Configuration
$+;
CODE SELECTION
$-?
GS1 DATABAR
disable the family
AQ0m
DISABLE CODE
ENABLE CODE
disable RSS Expanded Linear and Stacked
AQ10I
enable RSS Expanded Linear and Stacked
AQ11M
disable RSS Limited
AQ20L
enable RSS Limited
AQ21P
disable RSS 14 Linear and Stacked
AQ30O
enable RSS 14 Linear and Stacked
AQ31S
To read stacked codes, simply move the reader over the code so that each line of the code is
scanned. During this process a series of brief ticks indicates that reading is proceeding
correctly.
97
ADVANCED FORMATTING
NOT FOR PEN INTERFACES
~
~
CONCATENATION
ADVANCED FORMATTING
~
~
1.
2.
Read the Enter Configuration code ONCE, available at the top of page .
Read configuration codes precisely following the numbered procedure
given.
= Read the code and follow the procedure given
3.
98
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of
page.
Enter Configuration
$+;
ADVANCED FORMATTING
$-?
CONCATENATION
disable
EI0a
enable
EI1d
Permits the concatenation of two codes defined by code type and length. It is possible to set a
timeout for the second code reading and to define code transmission if the timeout expires.
The order of transmission is CODE 1-CODE 2.
Define Concatenation
Code 1
code ID
EK0e
Read the code type from the Code Identifier Table beginning in Appendix B.
code length
EL0g
Read a number in the range 01-99 from the Hex/Numeric Table.
99
ADVANCED FORMATTING
2
$-?
Code 2
code ID
EK1h
Read the code type from the Code Identifier Table beginning in Appendix B.
code length
EL1j
Read a number in the range 01-99 from the Hex/Numeric Table.
EN0k
use code 2 ID
EN1n
Since you can concatenate codes from different families, you must select the Code ID character
of the resulting code. The Code ID character will be sent in the output message only if it is
enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).
Concatenation Timeout
timeout
EJ3
Read two numbers in the range 00 to 99
00= no timeout
01-99 = timeout from 1 to 99 seconds
Define the timeout, which determines the valid waiting period between the two codes, in order to
accept concatenation. If the timeout expires, the resulting action will be based on the following
selection. (HHDII)
100
ADVANCED FORMATTING
5
$-?
EM0i
EM1l
EM2o
EM3r
101
ADVANCED FORMATTING
ADVANCED FORMATTING
Advanced formatting has been designed to offer you complete flexibility in changing the format
of barcode data before transmitting it to the host system. This formatting will be performed
when the barcode data meets certain criteria, which you will define in the following procedure.
Step 1
Begin Format Definition
1, 2, 3, or 4
Steps 2 - 4
Define Match Code Conditions
Step 5
Divide Code into Fields
Step 6
Define Code Fields
Steps 7 - 8
Add up to 2 Additional Fields
Step 9
Define Field Transmission
Step 10
Apply or Not
Standard Message Formatting
Step 11
End Format Definition
1, 2, 3, or 4
YES
Define another?
NO
102
Enter Configuration
$+;
1
ADVANCED FORMATTING
$-?
HA0T
begin Format 2 definition
HA1W
begin Format 3 definition
HA2Z
begin Format 4 definition
HA3]
2
HB&
Read the above code + the code type to match from the Code Identifier Table in Appendix B.
any code type
OR
HB0V
3
HC(
Read the above code + two numbers in the range 01 to 99 for the exact code length.
OR
HC001
103
ADVANCED FORMATTING
$-?
no match
HD0HE00
OR
HD1]
match with a 2-character string
HD2`
match with a 3-character string
HD3c
match with a 4-character string
HD4f
After selecting the predefined match code, read the character(s) from the HEX table. Range
of characters = 01-FE.
Example:
Match code with the 2-character predefined string = "@@".
Match with a 2-character string
+ 40 + 40
Read
AND
HE,
Read the above code + two numbers in the range 01 to 99 representing the character
position in the code where the first character of the predefined string must be found.
Read 00 if the match string can be found in any character position.
104
ADVANCED FORMATTING
$-?
HF.
Read one number in the range 1 to 5 to divide the code into fields.
OR BY
d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will
not be transmitted.
105
ADVANCED FORMATTING
$-?
HG0`
a)
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator
01
12
OR
match character
HG3i
b)
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
HG1c
c)
HG2f
d)
AND
Field 1 Terminators
no field terminators
HH0b
1 field terminator
2 field terminators
HH1e
HH2h
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.
106
ADVANCED FORMATTING
$-?
HG0`
a)
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator
01
12
OR
match character
HG3i
b)
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
HG1c
c)
HG2f
d)
AND
Field 2 Terminators
no field terminators
HH0b
1 field terminator
2 field terminators
HH1e
HH2h
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.
107
ADVANCED FORMATTING
$-?
HG0`
a)
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator
01
12
OR
match character
HG3i
b)
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
HG1c
c)
HG2f
d)
AND
Field 3 Terminators
no field terminators
HH0b
1 field terminator
2 field terminators
HH1e
HH2h
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.
108
ADVANCED FORMATTING
$-?
HG0`
a)
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator
01
12
OR
match character
HG3i
b)
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
HG1c
c)
HG2f
d)
AND
Field 4 Terminators
no field terminators
HH0b
1 field terminator
2 field terminators
HH1e
HH2h
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.
109
ADVANCED FORMATTING
$-?
HG0`
a)
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator
include separator
01
12
OR
match character
HG3i
b)
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
HG1c
c)
HG2f
d)
AND
Field 5 Terminators
no field terminators
HH0b
1 field terminator
2 field terminators
HH1e
HH2h
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.
110
ADVANCED FORMATTING
$-?
HI0d
1 character fixed field
HI1g
2 character fixed field
HI2j
3 character fixed field
HI3m
4 character fixed field
HI4p
5 character fixed field
HI5s
6 character fixed field
HI6v
After selecting one of the Additional Fixed Field codes, read the corresponding character(s)
from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is
also possible to read the Special Key(s) on page 58.
Example:
4 Character Fixed Field
+ 4D + 41 + 49 + 4E =
MAIN
111
ADVANCED FORMATTING
8
$-?
HJ0f
1 character fixed field
HJ1i
2 character fixed field
HJ2l
3 character fixed field
HJ3o
4 character fixed field
HJ4r
5 character fixed field
HJ5u
6 character fixed field
HJ6x
After selecting one of the Additional Fixed Field codes, read the corresponding character(s)
from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is
also possible to read the Special Key(s) on page 58.
Example:
3 Character Fixed Field
+ 53 + 45 + 54 =
112
SET
ADVANCED FORMATTING
$-?
Field Transmission
HK8
Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to
be transmitted.
Field Order Transmission
Read the codes corresponding to the fields to transmit in the order in which they are to be
transmitted. A field can be transmitted more than once. See example.
field 1
12
field 2
23
field 3
34
field 4
45
field 5
56
additional field 1
67
additional field 2
78
Example:
The barcode is divided into 3 defined fields plus 1 additional fixed field.
Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2.
Number of Fields
to Transmit
Field 2
+4+
Additional Field 1
Field 1
Field 2
113
ADVANCED FORMATTING
10
$-?
Standard Formatting
do not apply standard formatting
HL0j
HL1m
After performing Advanced Formatting on the barcode read, Standard Formatting (Headers,
Code Length, Code ID, Terminators) can be applied to the message to be transmitted.
11
HM0l
HM1o
HM2r
HM3u
114
Enter Configuration
$+;
ADVANCED FORMATTING
$-?
HN0n
Advanced Format 1
enable
HN11N
disable
HN10J
Advanced Format 2
enable
HN21Q
disable
HN20M
Advanced Format 3
enable
HN31T
disable
HN30P
Advanced Format 4
enable
HN41W
disable
HN40S
115
Enter Configuration
$+;
ADVANCED FORMATTING
$-?
No Match Result
clear data - no transmission
HO0p
transmit data using standard format
HO1s
This selection determines the action to be taken when codes read do not conform to the
advanced format requisites (no match).
Codes not matching can be ignored, cleared from memory and not transmitted.
Codes not matching can be transmitted using the Standard formatting (Headers, Code
Length, Code ID, Terminators).
116
RADIO PARAMETERS
~
~
~
~
~
~
~
~
~
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
3.
Read the Exit and Save Configuration code ONCE, available at the top of
each page.
117
Enter Configuration
$+;
RADIO PARAMETERS
$-?
RH<
Read a number from the table where:
02-19 =
2 seconds
POWER-OFF TIMEOUT
power-off timeout
RPL
Read 2 numbers in the range 00-99:
00 =
01-99 =
118
Enter Configuration
$+;
$-?
RADIO PARAMETERS
BF0X
only good decode
BF1[
only good reception
BF2^
off
BF3a
See par. 4.7.3 for details.
119
Enter Configuration
$+;
RADIO PARAMETERS
$-?
SINGLE STORE
disable
RO0z
one attempt
RO1}
two attempts
RO2
three attempts
RO3
four attempts
RO4
five attempts
RO5"
six attempts
RO6%
seven attempts
RO7(
eight attempts
RO8+
nine attempts
RO9.
See par. 4.7.4 for details
120
Enter Configuration
$+;
RADIO PARAMETERS
$-?
BATCH MODE
disable batch
BZ0
enable normal batch
BZ1
enable automatic batch
BZ2
See par. 4.7.5 for details.
The following batch management parameters are complete commands and do not
require reading the Enter and Exit configuration codes.
start normal batch transmission
#+BFlush]
delete batch data
#+BReset\
121
QUICKSCAN MOBILE
REFERENCES
4.1
4.1.1
RS-232 PARAMETERS
Handshaking
RTS
TX
Transmitted data
Transmitted data
Host busy
CTS
RTS/CTS handshaking
Transmitted data
TX
RX
XOFF
Host busy
XON
Host ready
XON/XOFF handshaking
122
REFERENCES
4.1.2
ACK/NACK Protocol
This parameter sets a transmission protocol in which the Host responds to the reader
after every code transmitted. The Host sends an ACK character (06 HEX) in the case
of good reception or the NACK character (15 HEX) requesting re-transmission, in the
case of bad reception.
data
QuickScan Mobile
cable
Host
ACK or NACK
ACK/NACK enabled
If the reader does not receive an ACK or NACK, transmission is ended after the RX
Timeout (see par. 4.1.4).
When ACK/NACK protocol is enabled, FIFO must be disabled manually, see par.
4.1.3.
The transmission protocol takes place between reader, cradle and Host. The reader
passes its data (code read) to the cradle, which sends it to the Host.
In the following descriptions the completed transmission is indicated by the Beeper
Control for Radio Response parameter with its default setting to Normal, see par.
4.7.3.
When ACK/NACK is disabled, there is no control from cradle to Host transmission,
the reader responds with the good reception tone.
data
data
QuickScan Mobile
CRADLE
cable
Host
good RX
beep
ACK/NACK disabled
data
data
cable
QuickScan Mobile
good RX
beep
CRADLE
NACK
Host
data
ACK
ACK/NACK enabled
123
QUICKSCAN MOBILE
When ACK/NACK is enabled, the Host sends an ACK character (06 HEX) in the case
of good reception or the NACK character (15 HEX) requesting re-transmission, in the
case of bad reception. Only after the ACK character is received by the cradle does
the reader respond with the good reception tone.
If the reader does not receive an ACK or NACK, transmission is ended after the RX
Timeout (see par. 4.1.4).
When ACK/NACK protocol is enabled, FIFO must be disabled manually, see par.
4.1.3.
4.1.3
FIFO
This parameter determines whether data (barcodes) are buffered on a First In First
Out basis allowing faster data collection in certain cases for example when using slow
baud rates and/or hardware handshaking.
If the FIFO buffering is enabled, codes are collected and sent out on the serial line in
the order of acquisition. About 800 characters can be collected (buffer full), after
which the reader signals an error and discards any further codes until the
transmission is restored.
If the FIFO buffering is disabled, each code must be transmitted before another one
can be read.
If enabled, the cradle collects all messages sent by QuickScan Mobile and sends
them in order of acquisition to the connected Host.
If disabled, QuickScan Mobile blocks message transmission until the cradle has
completed transmission towards the Host.
124
REFERENCES
4.1.4
RX Timeout
When the RS-232 interface is selected, the Host can be used to configure the device
by sending it command strings (see appendix A).
This parameter can be used to automatically end data reception from the Host after
the specified period of time.
If no character is received from the Host, after the timeout expires, any incomplete
string (any string not terminated by <CR>) is flushed from the device buffer.
4.2
4.2.1
PEN PARAMETERS
Minimum Output Pulse
This parameter sets the duration of the output pulse corresponding to the narrowest
element in the barcode. In this way the code resolution is controlled by the signal sent
to the decoder, independently of the physical resolution of the code read.
The shortest pulse (200 s) corresponds to a high resolution code emulation and
therefore a shorter transfer speed to the decoder (for decoders able to work on high
resolution codes). Likewise, longer pulses correspond to low resolution code
emulation and therefore a longer transfer time to the decoder.
4.2.2
When using these readers it is possible to choose between converting the decoded
codes into either Code 39 format or Code 128 format. It is not possible to disable
conversion.
125
QUICKSCAN MOBILE
4.2.3
Overflow
This parameter generates a white space before the first bar and after the last bar of
the code. The selections are as follows:
narrow
medium
wide
4.2.4
The following state diagrams describe the different output and idle level combinations
for Pen emulation:
idle
bar
OUTPUT: Normal
space
IDLE: Normal
black
white
barcode output
bar
OUTPUT: Normal
idle
IDLE: Inverted
space
black
white
barcode output
space
OUTPUT: Inverted
white
idle
bar
IDLE: Normal
black
barcode output
OUTPUT: Inverted
idle
white
space
bar
IDLE: Inverted
barcode output
126
black
REFERENCES
4.2.5
Inter-Block Delay
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20
characters each. The inter-block delay parameter allows setting a delay between
each block sent to the Host.
4.3
4.3.1
IBM 46XX
IBM Data Formatting (Transmission Format)
The IBM 46xx Series cash register recognizes the following codes:
Interleaved 2/5
Code 39
Codabar
Code 128
Code 93
Normal 2/5
The transmission format of codes belonging to this set is specified by the protocol. As
the reader allows a wider set of codes to be selected, the following formats are
defined to offer the user all the reading possibilities of the Datalogic product.
Conversion to Code 39 Format
Data from any code selected may be transmitted. Each code is transmitted to the
Host as Code 39. Any character not included in the standard Code 39 set will be
replaced with a Space (20 Hex).
IBM Standard Format
Only codes belonging to the above mentioned set may be transmitted. Each code
transmitted to the Host is recognized by the identifier requested by the protocol. If the
selected code does not belong to this set, it wiII not be transmitted.
Mixed IBM Standard + Code 39 Format
Data from any code selected may be transmitted. For codes belonging to the above
mentioned set, the IBM Standard Format is applied. The Code 39 Format applies
to codes not belonging to this set.
Cradle Check the Host Command and Cradle Ignore the Host Command
By default the cradle accepts the configuration commands received by the Host.
When the other command is selected, the cradle ignores completely the commands
sent from the Host and maintains its configuration.
127
QUICKSCAN MOBILE
4.4
DATA FORMAT
The system always provides reader to host data communication using the following
message formatting:
Output Message from QuickScan Dx30 or QuickScan Mobile Stand Alone Towards
Host
[Header] [Gun_Addr] [Gun_Addr_delimiter] ] [Code ID] [Code Length] CODE
[Terminator]
[Items in square brackets are optional.]
CODE [Terminator]
4.4.1
Header/Terminator Selection
The header/terminator selection is not effected by the reading of the restore default
code. In fact, header and terminator default values depend on the interface selection:
RS-232:
WEDGE:
These default values are always restored through the reading of RS-232 or WEDGE
interface selection code, see chapter 2.
128
REFERENCES
For the WEDGE interface, the following extended keyboard values can also be
configured:
EXTENDED KEYBOARD TO HEX CONVERSION TABLE
IBM AT
IBM 3153
APPLE ADB
IBM XT
Wyse
Digital
HEX
KEY
KEY
KEY
KEY
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
PG UP
PG DOWN
ESC
CTRL (Right)
Euro
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
ESC
BACKSPACE
HOME
END
PG UP
PG DOWN
ESC
CTRL (Right)
Space
FIELD EXIT
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
ENTER
RESET
INSERT
DELETE
FIELD FIELD +
ENTER (Paddle)
PRINT
RETURN
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
UP
DOWN
LEFT
RIGHT
ESC
CTRL (Right)
Space
Space
For all devices using IBM AT (compatible) Wedge or USB-KBD interfaces, all values from 9C to
FE send the relative simulated keypress when available or else the relative ALT-Mode
sequence. See the Hex to Character Conversion Table in Appendix C.
For all devices using other Wedge interfaces, all values from 9C to FE send the Space
character.
129
Enter Configuration
$+;
4.4.2
$-?
The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interface users can be
associated with a sequence of keyboard keys that otherwise could not be selected,
i.e. ALT + F6, SHIFT + F1. These Special Keys can be used for:
Headers/Terminators
Character Replacement
Field Adjustment
Custom Code ID
Advanced Formatting Define Field
Advanced Formatting Additional Fixed Field
Follow the procedure to define the desired Special Key sequence:
1.
Read the Enter Configuration code above and select the Special Key to define
(one at a time):
Define Special Key 1
FQ9C2>
Define Special Key 2
FQ9D2B
Define Special Key 3
FQ9E2F
Define Special Key 4
FQ9F2J
Define Special Key 5
FQA02q
130
$-?
2.
Read only one code to be associated with the special key sequence:
SHIFT
12
OR
CTRL
23
OR
ALT
45
OR
CTRL + SHIFT
34
OR
ALT + SHIFT
56
OR
CTRL + ALT
67
131
QUICKSCAN MOBILE
3.
!
"
#
$
%
&
'
(
)
*
+
,
.
/
0
1
2
3
4
5
6
7
8
9
132
ITA
USA
016
01E S
052 A
025 S
02E S
036 S
04E
03E S
046 S
05B S
05B
041
04A
049
03D S
045
016
01E
026
025
02E
036
03D
03E
046
016
052 S
026 S
025 S
02E S
03D S
052
046 S
045 S
03E S
055 S
041
04E
049
04A
045
016
01E
026
025
02E
036
03D
03E
046
FR
04A
026
026 A
05B
052 S
016
025
02E
04E
05D
055 S
03A
036
041 S
049 S
045 S
016 S
01E S
026 S
025 S
02E S
036 S
03D S
03E S
046 S
BE
03E
026
026 A
05B
052 S
016
025
02E
04E
05B S
04A S
03A
055
041 S
049 S
045 S
016 S
01E S
026 S
025 S
02E S
036 S
03D S
03E S
046 S
DE
S
016
01E S
05D
025 S
02E S
036 S
05D S
03E S
046 S
05B
05B
041
04A
049
03D S
045
016
01E
026
025
02E
036
03D
03E
046
UK
S
016
01E S
05D
025 S
02E S
03D S
052
046 S
045 S
03E S
055 S
041
04E
049
04A
045
016
01E
026
025
02E
036
03D
03E
046
ES
S
016
01E S
026 A
025 S
02E S
036 S
04E
03E S
046 S
05B S
05B
041
04A
049
03D S
045
016
01E
026
025
02E
036
03D
03E
046
SW
S
016
01E S
026 S
025 A
02E S
036 S
05D
03E S
046 S
05D S
04E
041
04A
049
03D S
045
016
01E
026
025
02E
036
03D
03E
046
JP
016 S
01E S
026 S
025 S
02E S
036 S
03D S
03E S
046 S
052 S
04C S
041
04E
049
04A
045
016
01E
026
025
02E
036
03D
03E
046
REFERENCES
KEYB
CHAR
:
;
<
=
>
?
@
[
\
]
^
_
(accent)
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
ITA
USA
FR
BE
DE
UK
ES
SW
JP
049 S
041 S
061
045 S
061 S
04E
04C A
054 A
00E
05B A
055 S
04A S
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
04C S
04C
041 S
055
049 S
04A S
01E S
054
05D
05B
036 S
04E S
00E
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
049
041
061
055
061 S
03A S
045 A
02E A
03E A
04E A
046 A
03E
03D A
015
032
021
023
024
02B
034
033
043
03B
042
04B
04C
031
044
04D
01C
02D
01B
02C
03C
02A
049
041
061
04A
061 S
03A S
01E A
054 A
061 A
05B A
054
055
05D A
015
032
021
023
024
02B
034
033
043
03B
042
04B
04C
031
044
04D
01C
02D
01B
02C
03C
02A
049 S
041 S
061
045 S
061 S
04E S
015 A
052 S
04C S
054 S
00E
04A S
055 S
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
04C S
04C
041 S
055
049 S
04A S
052 S
054
061
05B
036 S
04E S
00E
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
049 S
041 S
061
045 S
061 S
04E S
01E A
054 A
00E A
05B A
054 S
04A S
054
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
049 S
041 S
061
045 S
061 S
04E S
01E A
03E A
04E A
046 A
05B S
04A S
055 S
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
052
04C
041 S
04E S
049 S
04A S
054
05B
051
05D
055
051 S
054 S
01C
032
021
023
024
02B
034
033
043
03B
042
04B
03A
031
044
04D
015
02D
01B
02C
03C
02A
133
QUICKSCAN MOBILE
KEYB
CHAR
w
x
y
z
{
|
}
~
ITA
USA
FR
BE
01D
022
035
01A
00E S
-
01D
022
035
01A
054 S
05D S
05B S
00E S
01A
022
035
01D
025 A
036 A
055 A
01E A
01A
022
035
01D
046 A
016 A
045 A
04A A
DE
01D
022
01A
035
052
04C
054
04E
UK
ES
SW
JP
01D
022
035
01A
054 S
061 S
05B S
05D S
01D
022
035
01A
052 A
016 A
05D A
-
01D
022
035
01A
03D A
061 A
045 A
05B A
01D
022
035
01A
05B S
06A S
05D S
055 S
The following key values are common to all the keyboard nationalities.
KEYB
KEY
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
Home
End
PG UP
PG down
134
ITA
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
USA
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
FR
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
BE
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
DE
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
UK
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
ES
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
SW
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
JP
05A
00D
005
006
004
00C
003
00B
083
00A
001
009
078
007
26C
269
27D
27A
REFERENCES
KEYB
CHAR
ITA
Up arrow
Down
arrow
Left
arrow
Right
arrow
Esc
Ctrl
right
SPACE
USA
FR
BE
DE
UK
ES
SW
JP
275
275
275
275
275
275
275
275
275
272
272
272
272
272
272
272
272
272
26B
26B
26B
26B
26B
26B
26B
26B
26B
274
076
274
076
274
076
274
076
274
076
274
076
274
076
274
076
274
076
214
02E A
029
214
02E A
029
214
024 A
029
214
024 A
029
214
024 A
214
025 A
214
02E A
029
214
02E A
214
029
EXAMPLES
- Defining Special Key Sequences 1.
Read
$+;
FQ9C2>
003
SHIFT
12
$-?
135
QUICKSCAN MOBILE
2.
the following example allows defining Special Key 2 as CTRL + S (upper case):
enter configuration
Read
$+;
FQ9D2B
3.
CTRL + SHIFT
34
$-?
01B
Read
$+;
FQ9E2F
4.
ALT
45
$-?
00B
the following example allows defining Special Key 4 as Alt + Shift + F1:
enter configuration
Read
$+;
FQ9F2J
56
005
ALT + SHIFT
$-?
the following example allows setting Special Key 1 (defined in example 1 above)
as terminator:
enter configuration
Read
136
$+;
EA111
special key 1
9C
$-?
REFERENCES
2.
the following example allows setting Special Key 2 (defined in example 2 above)
as header:
enter configuration
Read
3.
$+;
EA01.
special key 2
9D
$-?
the following example allows setting Special Key 3 (defined in example 3 above)
as header:
enter configuration
Read
4.
$+;
EA01.
special key 3
9E
$-?
the following example allows setting Special Key 4 (defined in example 4 above)
and ENTER character as terminators:
enter configuration
Read
special key 4
$+; + EA125 + 9F +
ASCII characters
corresponding to the
HEX value for character
ENTER
83
4.4.3
$-?
Address Stamping
It is possible to include the reader address in the message sent to the host. The
reader Address Stamping parameter consists of a 4-digit number in the range
0000-1999.
For message output format, refer to par. 4.4.
4.4.4
Address Delimiter
137
QUICKSCAN MOBILE
4.4.5
For readers that have the Sleep state enabled, this timeout determines when the
reader will enter this state.
4.4.6
Standby
If this command is enabled, part of the CCD circuitry shuts down (Standby), in order
to optimize low power consumption when not reading. When the trigger is pressed
this circuitry powers up. This mode causes a minor delay of about 100 ms before the
reader is ready.
Standby is always enabled and is not configurable. To exit Standby press the trigger.
4.5
READING PARAMETERS
4.5.1
This mode determines how the reading phase is controlled when the hardware trigger
operating mode is selected:
trigger active level: the reader goes ON when the trigger is pressed and goes
OFF when it is released
trigger active pulse: the reader goes ON at the first trigger press and goes OFF
only at a second press
4.5.2
Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired
period of time.
4.5.3
138
For readers using the software trigger parameter (FLASH MODE), a reading
cycle corresponds to the flash on + flash off times. Code reading takes place
during the flash on time.
REFERENCES
For readers using the hardware trigger parameter, a reading cycle corresponds
to a trigger press (ON) + one of the following OFF events:
trigger release (for trigger active level)
a second trigger press (for trigger active pulse)
trigger-off timeout (see par. 4.5.2).
When one read per cycle is selected, the device decodes only one code during the
ON period and immediately turns the reader OFF. It is only possible to read another
code when the next ON time occurs.
In multiple reads per cycle, the ON period is extended so that the device can
continue decoding codes until an OFF event occurs. For software trigger mode, the
flash on period is immediately reset after each read and therefore extended. If
another code is decoded before the reset flash on period expires, it is again reset and
the effect is that the device remains ON, decoding codes until the flash on or timeout
period expires.
The Safety Time parameter should be used in this case to avoid unwanted multiple
reading of the same code, see par. 4.5.4.
4.5.4
Safety Time
Safety time prevents the device from immediately decoding the same code more than
once. Same code consecutive reading can be disabled requiring the reader to be
removed from the code (no decoding) for at least 400 ms, or a timeout can be set up
to 9.9 seconds before the decoder will accept the same code. Reading is immediate if
the code changes.
The safety time parameter is not applicable when reading stacked codes or when
setting one read per cycle in hardware trigger operating mode, since these settings
require voluntary action by the user.
4.6
DECODING PARAMETERS
CAUTION
4.6.1
Ink-Spread
The ink-spread parameter allows the decoding of codes, which are not perfectly
printed because the page texture tends to absorb the ink.
139
QUICKSCAN MOBILE
4.6.2
Overflow Control
The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which do not allow the use of an overflow space.
This command does not affect code families 2/5, Code 128 and Code 93.
4.6.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families Code
39 and Codabar.
4.7
4.7.1
RADIO PARAMETERS
Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the reader
and the cradle is considered failed.
This parameter should be set taking into consideration the radio traffic (number of
readers in the same area).
If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at
least equal to the RX Timeout parameter for low traffic environments. It should be
increased if there are many readers in the same area.
It can be set between 2 and 19 seconds.
4.7.2
Power-Off Timeout
If this command is enabled, after the desired timeout in hours, the batteries are
disconnected and all power consumption ceases. To restore power, press the trigger
once. The reader will now be ready to read codes.
Power-off does not affect configuration parameters.
4.7.3
The data entry good read tone normally results in two beeps; the first indicates that
the reader has decoded the code; the second indicates whether cradle has received
the data.
This can be changed according to the following selections:
Normal: both good decode and good reception are signaled (two beeps).
140
REFERENCES
Only Good Decode: only the first beep indicating a good read is signaled.
Only Good Reception: only the second beep indicating a good reception is
signaled.
Off: Neither good read nor good reception beeps are signaled.
For all configurations, any transmission errors will always be signaled.
4.7.4
Single Store
When single store mode is enabled, if the QuickScan Mobile fails to transmit a code
to the cradle, it enters a special operating mode that prevents the user from reading
barcodes. When such operating mode is entered, the trigger no longer enables
barcode reading but is used to retry transmission itself for the number of attempts
selected in configuration. Once the transmission is successful the reader returns to
the standard mode. If transmission is not successful after the number of configured
attempts, the code is discarded.
Single store may be useful if you often read codes at the limit of the coverage area
and there is a chance that code transmission can fail. In such case single store
allows you to move to a more favorable position or location (i.e. closer to the cradle)
and retry transmission without the necessity of re-reading the code since it is already
stored in the reader.
Conversely, if single store is disabled, and the user wants to retry transmission, the
code must be read again, and therefore the attempt must be made from basically the
same location. If the user gives up, he does not know if the transaction was
successful. (Actually the transmission could have been successful but the cradle may
have been unable to acknowledge the message). There are applications in which
there is no risk of transmission failure. In such cases it may be better to disable single
store so that the user perceives a more consistent behavior of the trigger in that it
always corresponds to code reading.
4.7.5
Batch Mode
This Operating Mode allows storing read codes in the internal reader RAM memory.
The stored codes are transmitted to the base station at a later time according to the
type of batch mode selected.
Batch mode can be enabled either manually (normal batch mode) or automatically.
Normal batch mode temporarily suspends radio communication between reader and
base station allowing codes to be stored in the reader on a FIFO basis. This can be
useful for example, if codes must be read from a location where there is no radio
network. Upon returning to the system working area, this mode requires reading the
Start Normal Batch Transmission barcode to successively transmit the list of
141
QUICKSCAN MOBILE
stored codes to the base station. The FIFO management assures that the first code
read will be the first code to be transmitted to the base station.
The Delete Batch Data barcode allows canceling all barcode data stored in the
reader.
Automatic batch mode allows codes to be stored in the reader on a FIFO basis
whenever the reader is out of radio range. In this case radio communication is not
suspended and transmission is attempted after each code read. If transmission
cannot be successfully completed, then the code is added to the list. When the
reader returns in range, transmission of the codes to the base station resumes
automatically, according to the selected communication protocol, upon simply
pressing and releasing the trigger or by successfully reading a new code.
142
REFERENCES
4.8
The following commands carry out their specific function and then exit the
configuration environment.
Command
Description
$+$*o
$+$!K
$+$&_
$+RX0$-q
$+RX1$-v
$+RX2$-{
143
QUICKSCAN MOBILE
4.9
The default values of the RS-232 and Data Format parameters for POS terminals are
listed in the following table:
NIXDORF Mode A
FUJITSU
ICL Mode
9600
Odd
8
1
Hardware (RTS/CTS)
Disabled
Disabled
Disabled
9.9 sec
Disabled
9600
None
8
1
None
Disabled
Enabled
Disabled
2 sec
Disabled
9600
Even
8
1
RTS always ON
Disabled
Enabled
Disabled
9.9 sec
Disabled
Custom
No Header
CR
Disabled
Not Transmitted
Disabled
Disabled
Disabled
Custom
No Header
CR
Disabled
Not Transmitted
Disabled
Disabled
Disabled
Custom
No Header
CR
Disabled
Not Transmitted
Disabled
Disabled
Disabled
RS-232 Group
Baud Rate
Parity
Data Bits
Stop Bits
Handshaking
ACK/NACK Protocol
FIFO
Inter-Character Delay
RX Timeout
Serial Trigger Lock
Data Format Group
Code Identifier
Header
Terminator
Field Adjustment
Code Length TX
Character Replacement
Address Stamping
Address Delimiter
The table below lists all the Code Identifiers available for the POS terminals:
CODE
UPC-A
UPC-E
EAN-8
EAN-13
Code 39
Codabar
Code 128
Interleaved 2 of 5
Code 93
Industrial 2 of 5
UCC/EAN 128
MSI/Plessey
RSS
Other
144
NIXDORF Mode A
A0
C0
B
A
M
N
K
I
L
H
P
O
E
None
FUJITSU
A
E
FF
F
None
None
None
None
None
None
None
None
None
None
ICL Mode
A
E
FF
F
C [code length]
N [code length]
L [code length]
I [code length]
None
H [code length]
L [code length]
None
None
None
TECHNICAL FEATURES
TECHNICAL FEATURES
QuickScan Mobile Reader and Cradle
5 VDC 5%
max. 4 W (charging)
Battery charging red
Charge completed green
Power / Data yellow
Optical Features
Sensor
Illuminator
Wavelength
Max. LED Output Power
LED safety class
Reading field
Max. resolution
PCS minimum
IP30
0 to 40 C (32 to 104 F)
-20 to 70 C (-4 to 158 F)
90 % non condensing
IP30
145
QUICKSCAN MOBILE
Radio Features
Radio Frequency
Bit rate
Effective Radiated Power
Range (in open air)
RF Modulation
146
European Models
USA Models
433.92 MHz
19200 baud
<10 mW
12 m
910 MHz
36800 baud
<1 mW
12 m
FSK
TECHNICAL FEATURES
5.1
Radio Features
Radio Frequency
433.92 MHz
Bit Rate
19200
30 m
RF Modulation
FSK
System Configurations
CRADLE
STARGATE
16
255
5.2
2000
-
16
STATUS INDICATORS
The reader has a LED indicator and a Beeper. The cradle has three LEDs.
They signal several operating conditions, which are described in the tables below.
H = high tone
L = low tone
READER START-UP
Beeper
LLLL
H H H H
long tones
HLHL
Meaning
Parameters loaded correctly
Parameter loading error, reading or writing error in the non volatile
memory
Hardware error in EEPROM
READER CONFIGURATION
Beeper
Meaning
HHHH
L
LLL
147
QUICKSCAN MOBILE
LED
Meaning
one beep
ON
H L long
between
QuickScan
Mobile
and
the cradle
H long
ON
HHH
H H long
Beeper
LED
Meaning
10 short H
10 short blinks
READER POWER
Low Battery
LED
Blinking
L
H L long
tones
Meaning
Command accepted; reader ready to be inserted into
the cradle
Success
Failure
148
TECHNICAL FEATURES
Green
LED
Yellow
LED
BEEPER
ON
Charging
ON
Blinking
End of charge
Blinking
Repetitive beep
ON
Blinking
5.3
Meaning
READING DIAGRAMS
QUICKSCAN MOBILE
(cm)
-15
CODE39
0.50 mm
(20 mils)
10
EAN13 M=1
0.33 mm
(13 mils)
0.13 mm
(5 mils)
-5
-10
-15
0
10
15
20
25
30
149
QUICKSCAN MOBILE
$+
Command
$-
CR
Carriage return character (0D Hex.)
Exit and Save configuration
Example:
Multiple command programming sequence:
$+
BG1 BH0
AC410132
$-
CR
Each configuration parameter setting removes the condition previously active for that
parameter.
NOTE
150
STRING
$+
$$*
$!
$&
INTERFACE SELECTION
DESCRIPTION
RS-232
Standard
ICL Mode
Fujitsu
Nixdorf Mode A
WEDGE for IBM AT
for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard
for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard
Keyboard Type for IBM Terminals 31xx, typewriter
32xx, 34xx, 37xx
advanced
for IBM XT
for IBM Terminal 3153
for IBM PC Notebook
for IBM SURE1
for IBM AT - ALT mode
for IBM PC Notebook - ALT mode
for Wyse Terminal - ANSI Keyboard
for Wyse Terminal - PC Keyboard
for Wyse Terminal - ASCII Keyboard
for Wyse Terminal - VT220 style Keyboard
for Digital Terminals VT2xx/3xx/4xx
for Apple ADB Bus
PEN EMULATION
USB
USB-KBD
USB-KBD-ALT-MODE
USB-KBD-APPLE
USB-COM
USB-IBM-Table Top
USB-IBM-Hand Held
STRING
CP0
CM0
CM1
CM2EC0
CP500
CP501
CP502
FK0
FK1
CP503
CP504
CP505
CP506
CP507
CP508
CP509
CP510
CP511
CP514
CP512
CP513
CP6
UA03
UA04
UA05
UA02
UA00
UA01
151
QUICKSCAN MOBILE
RS-232
DESCRIPTION
Baud rate
300
600
1200
2400
4800
9600
19200
38400
Parity
none
even
odd
Data bits
7
8
9
Stop bits
1
2
Handshaking
disable
RTS/CTS
XON/XOFF
RTS always On
ACK/NACK Protocol
disable
enable
FIFO
disable
enable
Inter-character delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock
disable
enable and select characters
STRING
CD1
CD2
CD3
CD4
CD5
CD6
CD7
CD8
CC0
CC1
CC2
CA0
CA1
CA2
CB0
CB1
CE0
CE1
CE2
CE3
ER0
ER1
EC0
EC1
CK00 - CK99
CL00 - CL99
CR0
CR1ab
a = Hex values representing an ASCII character from 00 to FE enabling the device trigger.
b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.
152
USB
DESCRIPTION
USB-COM
Handshaking
ACK/NACK Protocol
FIFO
Inter-character delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock
USB-KBD
Keyboard nationality
(not for USB-KBD-ALT-MODE)
FIFO
Delays
Control Character Emulation
USB Keyboard Speed
STRING
disable
RTS/CTS
XON/XOFF
RTS always ON
disable
enable
disable
enable
disable
enable
CE0
CE1
CE2
CE3
ER0
ER1
EC0
EC1
CK00 - CK99
CL00 - CL99
CR0
CR1ab
Belgian
English
French
German
Italian
Japanese
Spanish
Swedish
USA
disable
enable
Inter-Character (ms)
Inter-Code (s)
CTRL + Shift + Key
CTRL + Key
Normal
Fast
FJ7
FJ4
FJ2
FJ3
FJ1
FJ8
FJ6
FJ5
FJ0
EC0
EC1
CK00 - CK99
FG00 - FG99
FO0
FO1
UT10
UT01
a = Hex values representing an ASCII character from 00 to FE enabling the device trigger.
b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.
153
QUICKSCAN MOBILE
WEDGE
DESCRIPTION
Keyboard nationality
Caps Lock
Caps Lock Auto-Recognition
(IBM AT compatible only)
Num Lock
Delays
Control Character Emulation
Belgian
English
French
German
Italian
Spanish
Swedish
USA
Japanese (IBM AT compatible only)
caps Lock ON
caps Lock OFF
disable
enable
Toggle Num Lock
Num Lock Unchanged
Inter-Character (ms)
Inter-Code (s)
CTRL + Shift + Key
CTRL + Key
STRING
FJ7
FJ4
FJ2
FJ3
FJ1
FJ6
FJ5
FJ0
FJ8
FE1
FE0
FP0
FP1
FL1
FL0
CK00 - CK99
FG00 - FG99
FO0
FO1
PEN
DESCRIPTION
Operating mode
154
STRING
$]
$[
DG0
DG1
DG2
DG3
DG4
DG5
DA1
DA2
DD0
DD1
DE0
DE1
DH0
DH1
DH2
CK00-CK99
DATA FORMAT
disable
Datalogic standard
AIM standard
Custom
Terminators
Special Keys
no header
one character
two characters
three characters
four characters
five characters
six characters
seven characters
eight characters
no terminator
one character
two characters
three characters
four characters
five characters
six characters
seven characters
eight characters
special key 1
special key 2
special key 3
special key 4
special key 5
STRING
EB0
EB1
EB2
EB3
EHabc
EA00
EA01x
EA02xx
EA03xxx
EA04xxxx
EA05xxxxx
EA06xxxxxx
EA07xxxxxxx
EA08xxxxxxxx
EA10
EA11x
EA12xx
EA13xxx
EA14xxxx
EA15xxxxx
EA16xxxxxx
EA17xxxxxxx
EA18xxxxxxxx
9C
9D
9E
9F
A0
a = ASCII character.
b, c, x = HEX values representing an ASCII character.
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 52.
b = Hex value of the first Custom Code Identifier character from 00 to FD;
FF = disable Code Identifier
c = Hex value of the second Custom Code Identifier character from 00 to FD;
FF = disable second character of Custom Code Identifier
155
QUICKSCAN MOBILE
Field Adjustment
Address Stamping
Address Delimiter
not transmitted
transmitted in variable-digit format
transmitted in fixed 4-digit format
disable
right addition
left addition
right deletion
left deletion
disable character replacement
first character replacement
second character replacement
third character replacement
disable reader address stamping
enable reader address stamping
disable reader address delimiter
enable reader address delimiter and select
character
STRING
EE0
EE1
EE2
EF0
EFa0d
EFa1d
EFa2d
EFa3d
EGe
EO0
EO1afg
EO2afg
EO3afg
RU0
RU1
RV0
RV1h
a = ASCII character.
d = a number from the Hex/Numeric Table
e, f, g, h = HEX values representing an ASCII character
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 52.
d = a number in the range 01-32 from the Hex/Numeric Table
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE
g = Hex value of the new character to insert from 00 to FE
FF = replace with no new character (remove character)
156
READING PARAMETERS
DESCRIPTION
Hand-Held Operation
Stand Operation
Beeper Tone
Beeper Type
Beeper Length
Stand Recognition Beep
software trigger
hardware trigger
automatic
always on
hardware trigger ready
software trigger
hardware trigger
automatic
always on
trigger active level
trigger active pulse
one read
multiple reads
very low intensity
low intensity
medium intensity
high intensity
tone 1
tone 2
tone 3
tone 4
monotone
bitonal
long
short
disable
enable
STRING
BK0
BK1
BK2
BK3
BK4
BU1
BU3
BU0
BU2
BA0
BA1
BD00 - BD99
BB001 - BB099
BB101 - BB199
BC0
BC1
BE00 - BE99
BG0
BG1
BG2
BG3
BH0
BH1
BH2
BH3
BJ0
BJ1
BI0
BI1
Ba0
Ba1
157
QUICKSCAN MOBILE
DECODING PARAMETERS
DESCRIPTION
Ink-spread
Overflow control
Interdigit control
Puzzle Solver
TM
Decoding Safety
disable
enable
disable
enable
disable
enable
disable
enable
one read
two reads
three reads
four reads
CODE SELECTION
DESCRIPTION
DISABLE ALL FAMILY CODES
EAN/UPC disable EAN/UPC family
EAN 8/EAN 13/UPC A/UPC E
without ADD ON
with ADD ON
EAN 8/EAN 13
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
UPC A/UPC E
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
EAN/UPC with and without Add On no Autodiscrimination
EAN/UPC Autodiscrimination Add On by Prefix
Select Prefixes
cancel all selections
378/379
434/439
414/419
977
978
979
EAN 8 check digit transmission
Disable
Enable
EAN 13 check digit transmission
disable
enable
UPC A check digit transmission
disable
enable
158
STRING
AX0
AX1
AW1
AW0
AV0
AV1
AU0
AU1
ED0
ED1
ED2
ED3
STRING
AZ0
AA0
AA1
AA5
AA3
AAK
AAL
AA6
AA4
AAM
AAN
AA7
AA8Ad0
AA8Ad1
ET0
ET1378ET2379
ET3434ET4439
ET5414ET6419
ET7977
ET8978
ET9979
AAG0
AAG1
AAH0
AAH1
AAI0
AAI1
STRING
AAJ0
AAJ1
AAA
AAB
AAC
AAD
AP1
AP2
AP3
AP0
AB0
AB11
AB12
AB13
AB21
AB22
AB23
AB3
AB4
AB*xxxx
AC0
AC11xxxx
AC12xxxx
AC13xxxx
AC21xxxx
AC22xxxx
AC23xxxx
AC31xxxx
AC32xxxx
AC33xxxx
AC41xxxx
AC42xxxx
AC43xxxx
AC5
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
159
QUICKSCAN MOBILE
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
EXAMPLES:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
160
STRING
AD0
AD111
AD112
AD121
AD122
AD212
AD232
AD*xxxx
ADA0
ADA1
AI0
AI11
AI21
EQ0
EQ1
AI31
AILxxxx
AK0
AK1
AE0
AE1
AE2
AE3
AE4
AE5
AE6
AE7
STRING
Plessey
AF0
AF11
AF12
AF13
AF21
AF22
AF23
Telepen
AL0
AL11
AL12
AL13
AL21
AL22
AL23
AH0
AH1
AH2
AH3
AG0
AG1
AG21
AG22
AG31
AG32
AG41
AG42
AJ0
AJ1
AM0
AM1
AQ0
AQ10
AQ11
AQ20
AQ21
AQ30
AQ31
Delta IBM
Code 11
Code 16K
Code 49
GS1 DataBar
161
QUICKSCAN MOBILE
RADIO PARAMETERS
DESCRIPTION
Radio Protocol Timeout
enable (seconds)
Power-Off Timeout
Beeper Control For Radio Response normal
only good decode
only good reception
off
Single Store
disable
one attempt
two attempts
three attempts
four attempts
five attempts
six attempts
seven attempts
eight attempts
nine attempts
Batch Mode
disable
normal
automatic
162
STRING
RH02-RH19
RP00-RP99
BF0
BF1
BF2
BF3
RO0
RO1
RO2
RO3
RO4
RO5
RO6
RO7
RO8
RO9
BZ0
BZ1
BZ2
NO
2/5 Industrial
PQ
2/5 normal 5 bars
OP
2/5 matrix 3 bars
QR
EAN 8
AB
EAN 13
BC
UPC A
CD
UPC E
DE
EAN 8 with 2 ADD ON
JK
EAN 8 with 5 ADD ON
KL
EAN 13 with 2 ADD ON
LM
EAN 13 with 5 ADD ON
MN
UPC A with 2 ADD ON
FG
163
QUICKSCAN MOBILE
GH
UPC E with 2 ADD ON
HI
UPC E with 5 ADD ON
IJ
Code 39
VW
Code 39 Full ASCII
WX
CODABAR
RS
ABC CODABAR
ST
Code 128
TU
EAN 128
kl
Code 93
UV
CIP/39
YZ
CIP/HR
ef
Code 32
XY
ISBT 128
fg
164
MSI
Z[
Plessey Anker
op
Plessey Standard
ab
Delta IBM
cd
Telepen
de
Code 16K
pq
Code 11
bc
Code 49
qr
RSS Expanded Linear and Stacked
tu
RSS Limited
vw
RSS 14 Linear and Stacked
uv
165
QUICKSCAN MOBILE
166
char
hex
char
hex
char
hex
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
SPACE
!
"
#
$
%
&
'
(
)
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
*
+
,
.
/
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
U
V
W
X
Y
Z
[
\
]
^
_
`
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
~
DEL
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
hex
char
hex
char
hex
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
Reserved
Reserved
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
Pg UP
Pg Down
ESC
CTRL(Right)
NBSP
01
0
12
1
23
2
34
3
45
4
56
5
67
6
78
7
89
8
9:
9
AB
A
BC
B
CD
C
DE
D
EF
E
FG
F
Backspace
$%/
Cancels an incomplete configuration sequence
hex
char
hex
char
hex
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
Reserved
Reserved
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
HOME
END
Pg UP
Pg Down
ESC
CTRL(Right)
NBSP
01
0
12
1
23
2
34
3
45
4
56
5
67
6
78
7
89
8
9:
9
AB
A
BC
B
CD
C
DE
D
EF
E
FG
F
Backspace
$%/
Cancels an incomplete configuration sequence
07
dichiara che
declares that the
dclare que le
bescheinigt, da das Gert
declare que el
1999/5/EEC R&TTE
Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con las siguientes normas:
167
Australia
Japan
Datalogic Scanning KK
Telephone: 81 (0)3 3491 6761
japan.scanning@datalogic.com
Latin America
Germany
Singapore
India
Italy
United Kingdom
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
820001971 (Rev. B)
5/08