WIND LOADING ANALYSIS - Main Wind-Force Resisting System


Per ASCE 7-05 Code for Enclosed or Partially Enclosed Buildings
Using Method 2: Analytical Procedure (Section 6.5) for Buildings of Any Height
Job Name:
Operation warehouse
Subject:
Job Number:
Originator:
Checker:
Input Data:
Wind Direction =
Wind Speed, V =
Bldg. Classification =
Exposure Category =
Ridge Height, hr =
Eave Height, he =
Building Width =
Building Length =
Roof Type =
Topo. Factor, Kzt =
Direct. Factor, Kd =
Enclosed? (Y/N)
Damping Ratio, =
Period Coef., Ct =

Normal
85
II
C
42.06
28.87
98.43
401.57
Gable
1.00
0.85
Y
0.050
0.0200

(Normal or Parallel to building ridge)


mph (Wind Map, Figure 6-1)

Wind

(Table 1-1 Occupancy Cat.)


(Sect. 6.5.6)
ft. (hr >= he)
ft. (he <= hr)
ft. (Normal to Building Ridge)
ft. (Parallel to Building Ridge)
(Gable or Monoslope)
(Sect. 6.5.7 & Figure 6-4)
(Table 6-4)
(Sect. 6.2 & Figure 6-5)
(Suggested Range = 0.010-0.070)
(Suggested Range = 0.020-0.035)

Plan

o
hr

(Assume: T = Ct*h^(3/4) , and f = 1/T)

Resulting Parameters and Coefficients:

he

Roof Angle, =
Mean Roof Ht., h =

15.00
35.47

deg.
ft. (h = (hr+he)/2, for roof angle >10 deg.)

Windward Wall Cp =
Leeward Wall Cp =
Side Walls Cp =
Windward Roof Cp =
Windward Roof Cp =
Leeward Roof Cp =

0.80
-0.20
-0.70
-0.50
0.00
-0.50

(Fig. 6-6)
(Fig. 6-6)
(Fig. 6-6)

+GCpi Coef. =
-GCpi Coef. =

0.18
-0.18

(Figure 6-5) (positive internal pressure)


(Figure 6-5) (negative internal pressure)

Elevation
L = 98.4252 ft.
B = 401.574816 ft.

(Fig. 6-6)
(Fig. 6-6)
(Fig. 6-6)

(Condition #1)
(Condition #2)

If z <= 15 then: Kz = 2.01*(15/zg)^(2/) , If z > 15 then: Kz = 2.01*(z/zg)^(2/) (Table 6-3, Case 2a)
=
9.50
zg =
900
(Table 6-2)
Kh =
1.02
(Kh = Kz evaluated at z = h)
I=
1.00
(Table 6-1) (Importance factor)
Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd*V^2*I (Sect. 6.5.10, Eq. 6-15)
qh = 0.00256*Kh*Kzt*Kd*V^2*I (qz evaluated at z = h)
qh =
16.00
psf
Ratio h/L =
0.088
freq., f =
3.440
hz.
(f >= 1, Rigid structure)
Gust Factor, G =
0.850
(Sect. 6.5.8)
Design Net External Wind Pressures (Sect. 6.5.12.2):
p = qz*G*Cp - qi*(+/-GCpi) for windward wall (psf), where: qi =qh (Eq. 6-17, Sect. 6.5.12.2.1)
p = qh*G*Cp - qi*(+/-GCpi) for leeward wall, sidewalls, and roof (psf), where: qi = qh (Sect. 6.5.12.2.1)

1 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

2 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0
Normal to Ridge Wind Load Tabulation for MWFRS - Buildings of Any Height
z
Kz
qz
Cp
p = Net Design Press. (psf)
(ft.)
(psf)
(w/ +GCpi)
(w/ -GCpi)
Windward Wall
0
#VALUE!
#VALUE!
Surface

For z = he:
For z = h:
Leeward Wall
Side Walls
Roof (windward) cond. 1
Roof (windward) cond. 2
Roof (leeward)

28.87
35.47
All
All
-

0.97
1.02
-

15.32
16.00
-

0.80
0.80
-0.20
-0.70
-0.50

0.36
0.38
-0.27
-0.59
-0.46

0.64
0.66
0.01
-0.32
-0.19

0.00

-0.14

0.14

-0.50

-0.46

-0.19

Notes: 1. (+) and (-) signs signify wind pressures acting toward & away from respective surfaces.
2. Per Code Section 6.1.4.1, the minimum wind load for MWFRS shall not be less than 10 psf.
3. References : a. ASCE 7-02, "Minimum Design Loads for Buildings and Other Structures".
b. "Guide to the Use of the Wind Load Provisions of ASCE 7-02"
by: Kishor C. Mehta and James M. Delahay (2004).

3 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

Determination of Gust Effect Factor, G:


Is Building Flexible?

No

f >=1 Hz.

1: Simplified Method for Rigid Building


G=
0.850
Parameters Used in Both Item #2 and Item #3 Calculations (from Table 6-2):
^ =
0.105
b^ =
1.00
(bar) =
0.154
b(bar) =
0.65
c=
0.20
l=
(bar) =
z(min) =

500
0.200
15

ft.
ft.

Calculated Parameters Used in Both Rigid and/or Flexible Building Calculations:


z(bar) =
21.28
= 0.6*h , but not < z(min) , ft.
Iz(bar) =
0.215
= c*(33/z(bar))^(1/6) , Eq. 6-5
Lz(bar) =
gq =
gv =
gr =
Q=

457.99
3.4
3.4
4.474
0.880

= l*(z(bar)/33)^((bar))Eq. 6-7
(3.4, per Sect. 6.5.8.1)
(3.4, per Sect. 6.5.8.1)
= (2*(LN(3600*f)))^(1/2)+0.577/(2*LN(3600*f))^(1/2) , Eq. 6-9
= (1/(1+0.63*((B+h)/Lz(bar))^0.63))^(1/2) , Eq. 6-6

2: Calculation of G for Rigid Building


G=
0.864
= 0.925*((1+1.7*gq*Iz(bar)*Q)/(1+1.7*gv*Iz(bar))) , Eq. 6-4
3: Calculation of Gf for Flexible Building
=
0.050
Damping Ratio
Ct =
0.020
Period Coefficient
T=
0.291
= Ct*h^(3/4) , sec. (Approximate fundamental period)
f=
3.440
= 1/T , Hz. (Natural Frequency)
V(fps) =
N.A.
= V(mph)*(88/60) , ft./sec.
V(bar,zbar) =
N1 =

N.A.
N.A.

= b(bar)*(z(bar)/33)^((bar))*V*(88/60) , ft./sec. , Eq. 6-14


= f*Lz(bar)/(V(bar,zbar)) , Eq. 6-12

Rn =
h =

N.A.
N.A.

= 7.47*N1/(1+10.3*N1)^(5/3) , Eq. 6-11


= 4.6*f*h/(V(bar,zbar))

Rh =
b =
RB =
d =
RL =
R=
Gf =
Use: G =

N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
0.850

= (1/h)-1/(2*h^2)*(1-e^(-2*h)) for h>0, or = 1 for h=0 ,Eq. 6-13a,b


= 4.6*f*B/(V(bar,zbar))
= (1/b)-1/(2*b^2)*(1-e^(-2*b)) for b>0, or = 1 for b=0,Eq. 6-13a,b
= 15.4*f*L/(V(bar,zbar))
= (1/d)-1/(2*d^2)*(1-e^(-2*d)) for d>0, or = 1 for d=0 ,Eq. 6-13a,b
= ((1/)*Rn*Rh*RB*(0.53+0.47*RL))^(1/2) , Eq. 6-10
= 0.925*(1+1.7*Iz(bar)*(gq^2*Q^2+gr^2*R^2)^(1/2))/(1+1.7*gv*Iz(bar)) ,
Eq. 6-8

4 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

5 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

Figure 6-9 - Design Wind Load Cases of MWFRS for Buildings of All Heights

Case 1: Full design wind pressure acting on the projected area perpendicular to each principal axis of
the structure, considered separately along each principal axis.
Case 2: Three quarters of the design wind pressure acting on the projected area perpendicular to each
principal axis of the structure in conjunction with a torsional moment as shown, considered
separately for each principal axis.
Case 3: Wind pressure as defined in Case 1, but considered to act simultaneously at 75% of the
specified value.
Case 4: Wind pressure as defined in Case 2, but considered to act simultaneously at 75% of the
specified value.
Notes: 1. Design wind pressures for windward (Pw) and leeward (PL) faces shall be determined in
accordance with the provisions of Section 6.5.12.2.1 and 6.5.12.2.3 as applicable for buildings
of all heights.
2. Above diagrams show plan views of building.
3. Notation:
Pwx, Pwy = Windward face pressure acting in the X, Y principal axis, respectively.
PLx, PLy = Leeward face pressure acting in the X, Y principal axis, respectively.
e (ex, ey) = Eccentricity for the X, Y principal axis of the structure, respectively.
MT = Torsional moment per unit height acting about a vertical axis of the building.

6 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

WIND LOADING ANALYSIS - Main Wind-Force Resisting System


Per ASCE 7-05 Code for Enclosed or Partially Enclosed Buildings
Using Method 2: Analytical Procedure (Section 6.5) for Buildings of Any Height
Job Name:
ADMIN BUILDING A
Subject:
Job Number:
Originator:
Checker:

Parallel
I
II
III
IV
B
C
B D
Gable
Monoslope
Y
N
For h/L<=0.25:
For h/L=0.5:
For h/L>=1.0:
actual h/L =
Use Roof Cp =

Input Data:
Wind Direction =
Wind Speed, V =
Bldg. Classification =
Exposure Category =
Ridge Height, hr =
Eave Height, he =
Building Width =
Building Length =
Roof Type =
Topo. Factor, Kzt =
Direct. Factor, Kd =
Enclosed? (Y/N)
Damping Ratio, =
Period Coef., Ct =

Parallel
85
II
C
42.06
28.87
98.43
401.57
Gable
1.00
0.85
Y
0.050
0.0200

(Normal or Parallel to building ridge)


mph (Wind Map, Figure 6-1)

Wind

(Table 1-1 Occupancy Cat.)


(Sect. 6.5.6)
ft. (hr >= he)
ft. (he <= hr)
ft. (Normal to Building Ridge)
ft. (Parallel to Building Ridge)
(Gable or Monoslope)
(Sect. 6.5.7 & Figure 6-4)
(Table 6-4)
(Sect. 6.2 & Figure 6-5)
(Suggested Range = 0.010-0.070)
(Suggested Range = 0.020-0.035)

Plan

o
hr

(Assume: T = Ct*h^(3/4) , and f = 1/T)

Resulting Parameters and Coefficients:

he

Roof Angle, =
Mean Roof Ht., h =

15.00
35.47

deg.
ft. (h = (hr+he)/2, for roof angle >10 deg.)

Windward Wall Cp =
Leeward Wall Cp =
Side Walls Cp =
Roof Cp (zone #1) =
Roof Cp (zone #2) =
Roof Cp (zone #3) =
Roof Cp (zone #4) =
+GCpi Coef. =
-GCpi Coef. =

0.80
-0.20
-0.70
-0.90
-0.90
-0.50
-0.30
0.18
-0.18

(Fig. 6-6)
(Fig. 6-6)
(Fig. 6-6)
-0.18
-0.18
-0.18
-0.18
(Figure 6-5)
(Figure 6-5)

Elevation
L = 401.574816
B = 98.4252 ft.

=
zg =
Kh =
I=
qh =

(Fig. 6-6)
(zone #1 for 0 to h/2)
(Fig. 6-6)
(zone #2 for h/2 to h)
(Fig. 6-6)
(zone #3 for h to 2*h)
(Fig. 6-6)
(zone #4 for > 2*h)
(positive internal pressure)
(negative internal pressure)

If z <= 15 then: Kz = 2.01*(15/zg)^(2/) , If z > 15 then: Kz = 2.01*(z/zg)^(2/) (Table 6-3, Case 2a)
=
9.50
zg =
900
(Table 6-2)
Kh =
1.02
(Kh = Kz evaluated at z = h)
I=
1.00
(Table 6-1) (Importance factor)
Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd*V^2*I (Sect. 6.5.10, Eq. 6-15)
qh = 0.00256*Kh*Kzt*Kd*V^2*I (qz evaluated at z = h)
qh =
16.00
psf
Ratio h/L =
0.088
freq., f =
3.440
hz.
(f >= 1, Rigid structure)
Gust Factor, G =
0.850
(Sect. 6.5.8)
Design Net External Wind Pressures (Sect. 6.5.12.2):
p = qz*G*Cp - qi*(+/-GCpi) for windward wall (psf), where: qi =qh (Eq. 6-17, Sect. 6.5.12.2.1)
p = qh*G*Cp - qi*(+/-GCpi) for leeward wall, sidewalls, and roof (psf), where: qi = qh (Sect. 6.5.12.2.1)

7 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

8 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0
Parallel to Ridge Wind Load Tabulation for MWFRS - Buildings of Any Height
z
Kz
qz
Cp
p = Net Design Press. (psf)
(ft.)
(psf)
(w/ +GCpi)
(w/ -GCpi)
Windward Wall
0
#VALUE!
Surface

For z = he:
For z = h:
Leeward Wall
Side Walls
Roof (zone #1) cond. 1
Roof (zone #1) cond. 2
Roof (zone #2) cond. 1
Roof (zone #2) cond. 2
Roof (zone #3) cond. 1
Roof (zone #3) cond. 2
Roof (zone #4) cond. 1
Roof (zone #4) cond. 2

28.87
35.47
All
All
-

0.97
1.02
-

15.32
16.00
-

0.80
0.80
-0.20
-0.70
-0.90
-0.18
-0.90
-0.18
-0.50
-0.18
-0.30
-0.18

0.36
0.38
-0.27
-0.59
-0.72
-0.26
-0.72
-0.26
-0.46
-0.26
-0.33
-0.26

0.64
0.66
0.01
-0.32
-0.45
0.02
-0.45
0.02
-0.19
0.02
-0.06
0.02

Notes: 1. (+) and (-) signs signify wind pressures acting toward & away from respective surfaces.
2. Per Code Section 6.1.4.1, the minimum wind load for MWFRS shall not be less than 10 psf.
3. References : a. ASCE 7-02, "Minimum Design Loads for Buildings and Other Structures".
b. "Guide to the Use of the Wind Load Provisions of ASCE 7-02"
by: Kishor C. Mehta and James M. Delahay (2004).
4. Roof zone #1 is applied for horizontal distance of 0 to h/2 from windward edge.
5. Roof zone #2 is applied for horizontal distance of h/2 to h from windward edge.
6. Roof zone #3 is applied for horizontal distance of h to 2*h from windward edge.
7. Roof zone #4 is applied for horizontal distance of > 2*h from windward edge.

9 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

Determination of Gust Effect Factor, G:


Is Building Flexible?

No

f >=1 Hz.

1: Simplified Method for Rigid Building


G=
0.850
Parameters Used in Both Item #2 and Item #3 Calculations (from Table 6-2):
^ =
0.105
b^ =
1.00
(bar) =
0.154
b(bar) =
0.65
c=
0.20
l=
(bar) =
z(min) =

500
0.200
15

ft.
ft.

Calculated Parameters Used in Both Rigid and/or Flexible Building Calculations:


z(bar) =
21.28
= 0.6*h , but not < z(min) , ft.
Iz(bar) =
0.215
= c*(33/z(bar))^(1/6) , Eq. 6-5
Lz(bar) =
gq =
gv =
gr =
Q=

457.99
3.4
3.4
4.474
0.880

= l*(z(bar)/33)^((bar))Eq. 6-7
(3.4, per Sect. 6.5.8.1)
(3.4, per Sect. 6.5.8.1)
= (2*(LN(3600*f)))^(1/2)+0.577/(2*LN(3600*f))^(1/2) , Eq. 6-9
= (1/(1+0.63*((B+h)/Lz(bar))^0.63))^(1/2) , Eq. 6-6

2: Calculation of G for Rigid Building


G=
0.864
= 0.925*((1+1.7*gq*Iz(bar)*Q)/(1+1.7*gv*Iz(bar))) , Eq. 6-4
3: Calculation of Gf for Flexible Building
=
0.050
Damping Ratio
Ct =
0.020
Period Coefficient
T=
0.291
= Ct*h^(3/4) , sec. (Approximate fundamental period)
f=
3.440
= 1/T , Hz. (Natural Frequency)
V(fps) =
N.A.
= V(mph)*(88/60) , ft./sec.
V(bar,zbar) =
N1 =

N.A.
N.A.

= b(bar)*(z(bar)/33)^((bar))*V*(88/60) , ft./sec. , Eq. 6-14


= f*Lz(bar)/(V(bar,zbar)) , Eq. 6-12

Rn =
h =

N.A.
N.A.

= 7.47*N1/(1+10.3*N1)^(5/3) , Eq. 6-11


= 4.6*f*h/(V(bar,zbar))

Rh =
b =
RB =
d =
RL =
R=
Gf =
Use: G =

N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
0.850

= (1/h)-1/(2*h^2)*(1-e^(-2*h)) for h>0, or = 1 for h=0 ,Eq. 6-13a,b


= 4.6*f*B/(V(bar,zbar))
= (1/b)-1/(2*b^2)*(1-e^(-2*b)) for b>0, or = 1 for b=0,Eq. 6-13a,b
= 15.4*f*L/(V(bar,zbar))
= (1/d)-1/(2*d^2)*(1-e^(-2*d)) for d>0, or = 1 for d=0 ,Eq. 6-13a,b
= ((1/)*Rn*Rh*RB*(0.53+0.47*RL))^(1/2) , Eq. 6-10
= 0.925*(1+1.7*Iz(bar)*(gq^2*Q^2+gr^2*R^2)^(1/2))/(1+1.7*gv*Iz(bar)) ,
Eq. 6-8

10 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

11 of 18

06/25/2015 09:46:18

"ASCE705W.xls" Program
Version 1.0

Figure 6-9 - Design Wind Load Cases of MWFRS for Buildings of All Heights

Case 1: Full design wind pressure acting on the projected area perpendicular to each principal axis of
the structure, considered separately along each principal axis.
Case 2: Three quarters of the design wind pressure acting on the projected area perpendicular to each
principal axis of the structure in conjunction with a torsional moment as shown, considered
separately for each principal axis.
Case 3: Wind pressure as defined in Case 1, but considered to act simultaneously at 75% of the
specified value.
Case 4: Wind pressure as defined in Case 2, but considered to act simultaneously at 75% of the
specified value.
Notes: 1. Design wind pressures for windward (Pw) and leeward (PL) faces shall be determined in
accordance with the provisions of Section 6.5.12.2.1 and 6.5.12.2.3 as applicable for buildings
of all heights.
2. Above diagrams show plan views of building.
3. Notation:
Pwx, Pwy = Windward face pressure acting in the X, Y principal axis, respectively.
PLx, PLy = Leeward face pressure acting in the X, Y principal axis, respectively.
e (ex, ey) = Eccentricity for the X, Y principal axis of the structure, respectively.
MT = Torsional moment per unit height acting about a vertical axis of the building.

12 of 18

06/25/2015 09:46:18

Wind
Direction

Surface

Member

Height

P calculation

(m)

qz (kN/m2)

Cp

qi (kN/m2)

Gcpi

Windward wall

Column line A

8.88 m

0.733

0.85

0.80

0.760

+/-0.18

Leeward wall

Column line L

10.81 m

0.760

0.85

-0.20

0.760

+/-0.18

Side wall

Column line1

10.81 m

0.760

0.85

-0.70

0.760

+/-0.18

Windward Roof

Rafter line 1 & 21

10.81 m

0.760

0.85

-0.5

0.760

+/-0.18

10.81 m

0.760

0.85

-0.5

0.760

+/-0.18

Z-Dir
Rafter line 2 & 20
Leeward Roof

Rafter line 7

P= Net Design Press (kN/m2)

h=
z=

P use

Area

W = PxA

qz*G*Cp-qi*+Gcpi

qz*G*Cp-qi*-Gcpi

kN/m2

(m)

(kN/m)

0.37

0.63

0.63

1.890

Zg =

3.780

-0.810

-1.620

-1.770

-3.540

-1.38

L=
B=
V=
I=
-Gcpi =

-0.27
-0.59

0.01
-0.31

-0.27
-0.59

-0.46

-0.19

-0.46

-0.46

-0.19

-0.46

-2.76

-1.380

-2.760

10.81
8.8

Kz = 2.01*(z/Zg)2/ =
274.32
9.5

122.4
60
38
1
-0.18

When angle roof =


m

10 degree

0.97
(table 6-2 ASCE in metric)
(table 6-2 ASCE)
m
m
m/s

Kh =

1.02

Wind
Direction

X-Dir

Surface

Member

Height
(m)

qz (kN/m2)

P calculation
Cp
qi (kN/m2)

Windward wall

Column Line A

8.88 m

0.733

0.85

0.80

0.760

Leeward wall

Column Line L

10.81 m

0.760

0.85

-0.20

0.760

Side Wall

Column Line 1 & 21

10.81

0.76

0.85

-0.70

0.76

WindWard Roof

Rafter Line 1

10.81 m

0.760

0.85

-0.9

0.760

-0.18
Rafter Line 2 & 3

-0.9
-0.18

Rafter Line 4

-0.5/-0.18

Rafter Line 5 - 21

-0.3/-0.18

n
Gcpi
+/-0.18

+/-0.18

+/-0.18

+/-0.18

P= Net Design Press (kN/m2)


qz*G*Cp-qi*+Gcpi
qz*G*Cp-qi*-Gcpi
0.37

-0.27

-0.59

0.63

0.01

-0.31

-0.72

-0.44

-0.26

0.03

-0.72

-0.44

-0.26

0.03

P use
kN/m2

Area
(m)

W = PxA
(kN/m)

Roof Angle 25 Deg

0.63

1.890

3.780

L=
B=

122.4
60

hr =
he =
h=

18.82
8.8
10.81

h/L =

0.088

-0.27

-0.59

-0.810

-1.620

-1.770

-3.540

-0.72

-2.160

-0.72

-4.320

-0.46

0.03

-0.46

-2.76

-0.33

-0.05

-0.33

-0.99

For Cp, where h/l 0.5, use Cp


0 to h/2
-0.9
h/2 to h
-0.9
h to 2h
-0.5
2h
-0.3

m
m
m
m
m
m

here h/l 0.5, use Cp


-0.18
-0.18
-0.18
-0.18