In This Appendix. . . .
Connecting to DirectLOGIC PLCs
Connecting to AllenBradley (AB) PLCs
Connecting to a WinPLC
The Programming Cable (DPPGMCBL)
DirectTouch Cable pin-outs
DirectTouch Panel Specifications
Panel Dimensions and Installation
1A
Appendix A
Connecting to a PLC
A2
Connecting to a PLC
1
Step 1
2
Step 2
System Check
Up/Download
User Mode
A3
Connecting to a PLC
RS232C
Setup
Pushbutton
Setup
Printer
Setup
RS422/485
Setup
Display
Control
RAM File
Setup
Host Command
Setup
Clock
Setup
Appendix A
Connecting to a PLC
System Setup
Display
Direction
Error Disp
Setup
End
NOTE: Initially, the panel is set to Not Used on both RS232C and RS422/485.
RS232C Setup
Press the RS232C Setup button first, then the Connected Device
button and select PLC (and ENT). Press enter (ENT) again for the change to
take effect.
Connected
Device
PLC
RS232C
Communication
Rate
Parity Check
9600
ODD
bps
RS232C
Not Used
RS422/485
Stop Bit
Data Length
Not Used
8
Detail
ENT
ESC
Appendix A
Connecting to a PLC
A4
Connecting to a PLC
NOTE: Initially, the panel is set to Not Used on both RS232C and RS422/485.
RS422 Setup
PLC
RS422/485
Communication
Rate
Parity Check
9600
bps
RS232C
Not Used
ODD
Stop Bit
Data Length
RS422/485
Not Used
1
8
Detail
ENT
ESC
During configuration/programming, we found this setup very helpful for the D2250:
Programming Cable
DPPGMCBL
RS422
RS232
Serial Cable
(CH3)
(CH1)
(Straight through)
B
A
DirectTouch panel
Data Switch
D2DSCBL
D2250
If using RS422, the PLC and panel can remain connected while
both may be configured/programmed by the PC using a switch.
Pig-tail Cable
D2DSCBL2
(for RS422)
FG
RS422
(CH3)
SG
Black/White
RD
Yellow/White
RD+
Yellow
SD
Orange
SD+
Orange/White
Connecting to a PLC
If RS232C is used for panel/PLC connection, follow the same steps above, only
set RS232C as the PLC and RS422 as Not Used.
3. Connect the PLC to the panel through the proper cable below. For cable
pinouts, see page A15.
Step 3
DirectTouch Cables
Family
PLC
(or other device)
Cable
DirectLOGICt
DL05
D005xx
Port1 or Port2
DP2CBL
DirectLOGICt
DL105
F1130
Only one
DP2CBL
DirectLOGICt
DL205
D2230
Only one
DP2CBL
D2240
Top port
DP2CBL
DirectLOGICt
DL305
Bottom port
DP2CBL
D2250
Top port
Bottom port
Bottom port (RS422)
DP2CBL
DP2CBL1
D2DSCBL2
D2DCM
Only one
DP3CBL2
D3340
Top port
DP3CBL
Bottom port
DP3CBL
DP2CBL
Bottom port
Bottom port (RS422)
DP3CBL2
D2DSCBL2
Only one
DP3CBL2
D4430
DP4CBL
DP3CBL2
DP4CBL
DP3CBL2
Phone Jack
DP2CBL
DP4CBL
D2DSCBL2
DP3CBL2
D3350
DirectLOGICt
DL405
D4440
D4450
Programming
Cable
(DPPGMCBL)
Port
D4DCM
Only one
DP3CBL2
Allen-Bradleyt
SLC 500
Bottom port
DPABCBL1
WinPLC
WinPLC
DP2CBL
Belden 9729
(or equal)
Allen-Bradleyt
MicroLogixt
Only one
DPABCBL2
See page A15 for information regarding the DirectTouch panel programming
cable (DPPGMCBL).
Appendix A
Connecting to a PLC
RS232C
(panel/PLC)
A5
Appendix A
Connecting to a PLC
A6
Connecting to a PLC
Press the upper left and lower right corners of the panel screen to
bring up the System Mode Main Menu screen below and press System Setup.
System Mode Main Menu
System Setup
System Check
Up/Download
User Mode
System Setup
RS232C
Setup
Pushbutton
Setup
Printer
Setup
RS422/485
Setup
Display
Control
RAM File
Setup
Host Command
Setup
Clock
Setup
Display
Direction
Error Disp
Setup
End
A7
Connecting to a PLC
RS232C Setup
Press the RS232C Setup button first, then the Connected Device
button and select PLC (and ENT). Press enter (ENT) again for the change to
take effect.
Connected
Device
PLC
RS232C
Communication
Rate
Parity Check
9600
EVEN
bps
RS232C
Not Used
RS422/485
Stop Bit
Data Length
Not Used
8
Detail
RS232C
(panel/PLC)
1
Step 1
Channel 0
(RS232C) Setup
ENT
ESC
Appendix A
Connecting to a PLC
NOTE: Initially, the panel is set to Not Used on both RS232C and RS422/485.
Appendix A
Connecting to a PLC
A8
Connecting to a PLC
Step 2
Chan. 1 (DH 485)
Setup
Programming Cable
DPPGMCBL
DirectTouch panel
Data
Switch
DPABCBL1 Cable
(DPABCBL2 for
Micrologix)
Serial Cable
(Straight through)
SLC 5/03
or 5/04
Unfortunately, there is no easy way to configure/program
the AB PLCs at the same time as the DirectTouch panel.
NOTE: Use two different PC comm ports, for AllenBradley, one to the panel and
one for programming the PLC. Using a single port for both causes conflicts.
3
Step 3
3. For SLCs: Connect the AB PLC (bottom port) to the DirectTouch panel through
the DPABCBL1 cable.
3. For Micrologix: Connect the AB PLC (only port) to the DirectTouch panel
through the DPABCBL2 cable.
NOTE: For Micrologix PLCs, set the Error Detection to CRC!
Connecting to a PLC
A9
Bit Addresses
Word Addresses
File
Number
Element Range
element (e), word (w)
Element Value
Range
Bit Range
bit (b)
Status (Sf:e/b)
0255
32768 to 32767
015
3, 9255
0255
32768 to 32767
015
Timer (Tf:e.w/b)
4, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Counter (Cf:e.w/b)
5, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Control (Rf:e.w/b)
6, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Integer (Nf:e/b)
7, 9255
0255
32768 to 32767
015
8, 9255
0255
1.1754944e38 to 015
3.40282347e+38
In order to indicate the status of, or write to, Input/Output bits, a single Bit address
must be assigned to each Input/Output bit in a ladder logic rung (by an Output
Energize Coil).
File
Number
Element Range
element (e), word (w)
Element Value
Range
Bit Range
bit (b)
Status (Sf:e/b)
0255
32768 to 32767
015
3, 9255
0255
32768 to 32767
015
Timer (Tf:e.w/b)
4, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Counter (Cf:e.w/b)
5, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Control (Rf:e.w/b)
6, 9255
e: 0255, w: 02 *
32768 to 32767
015 *
Integer (Nf:e/b)
7, 9255
0255
32768 to 32767
015
In order to indicate the status of, or write to, Input/Output bits, a single Bit address
must be assigned to each Input/Output bit in a ladder logic rung (by an Output
Energize Coil).
Appendix A
Connecting to a PLC
Appendix A
Connecting to a PLC
A10
Connecting to a PLC
Controller
Properties
The DirectTouch panel now supports the Standard Modbus protocol. The Standard
Modbus protocol is also known as Modbus RTU. Please refer to your PLC User
Manual for details on the Modbus protocol and data ranges.
Connecting to a PLC
A11
Requirements
The following products and versions are required to connect a WinPLC to the
DirectTouch panel:
S WinPLC, Revision Code 4D or later
S Think & Do Software, V5.2 or higher
S ScreenCreator, V1.14 or higher
DirectTouch Setup
Press the upper left and lower right corners of the panel screen to
bring up the System Mode Main Menu screen below and press System Setup.
System Mode Main Menu
System Setup
System Check
Up/Download
User Mode
System Setup
RS232C
Setup
Pushbutton
Setup
Printer
Setup
RS422/485
Setup
Display
Control
RAM File
Setup
Host Command
Setup
Clock
Setup
Display
Direction
Error Disp
Setup
End
Appendix A
Connecting to a PLC
Appendix A
Connecting to a PLC
A12
Connecting to a PLC
NOTE: Initially, the panel is set to Not Used on both RS232C and RS422/485.
RS232C Setup
Press the RS232C Setup button first, then the Connected Device
button and select PLC (and ENT). Press enter (ENT) again for the change to
take effect.
Make sure at this point to set the Communication Rate (Baud rate) and Parity
Check the same as that of the WinPLC.
Connected
Device
PLC
RS232C
Communication
Rate
Parity Check
9600
EVEN
bps
RS232C
Not Used
RS422/485
Stop Bit
Data Length
Not Used
1
8
Detail
ENT
ESC
During configuration/programming, we found this setup very helpful for the WinPLC:
Cable for
RS422 (Belden 9729 or
Programming Cable
equal)
RS422
DPPGMCBL
RS232
(CH3)
(CH1)
DirectTouch panel
Ethernet 10BaseT
Cable
WinPLC in a
DL205 Base
FAUNICON or FA
ISONET (RS232 to
RS422 converter)
NOTE: You do not have to use the setup shown above. You can program the panel
and WinPLC separately and connect them together by RS232 (Cable DP2CBL) if
you choose.
Connecting to a PLC
Appendix A
Connecting to a PLC
Creating a New
Project for a
WinPLC
Application
A13
Appendix A
Connecting to a PLC
A14
Connecting to a PLC
A15
Connecting to a PLC
The Programming
Cable
(DPPGMCBL)
Regardless of which PLC is used with the panel, the programming cable
(DPPGMCBL) is used to connect the panel to the personal computer.
Connect the programming cable (DPPGMCBL) between the serial port (CH1) of
the DirectTouch panel and the serial port of the personal computer.The figure below
shows programming cable connectors and wiring specifications. Wiring diagrams
refer to the communication ports.
Female
DB9
Female
DB9
shell
2
3
8
7
4
5
5= 0V
4= DTR
3= Dout
2= Din
1= DCD
9= not used
8= CTS
7= RTS
6= DSR
DirectTouch Panel
Male
DB9
shell
2
3
4
5
1
7
Male
DB9
1 = Ground
2 = Dout
3 = Din
4 = RTS
5 = CTS
DirectTouch Cable
Pin-outs
6 = not used
7 = 0V
8 = not used
9 = not used
9
DP2CBL
Panel
PLC
Male
DP3CBL2
Panel
PLC
Phone jack
DB9
2
3
4
5
7
DB9
2
3
4
5
7
VGA 15
3
2
4
5
7
DPABCBL1
Panel
PLC
Male
DB9
2
3
7
4
5
25pin Male
25pin
3
2
4
5
7
DP4CBL
Panel
PLC
DP2CBL1
Panel
PLC
Male
Male
DB9
2
3
4
5
7
RJ12
3
4
9pin Female
DB9
2
3
5
7
8
Male
DB9
2
3
7
4
5
DPABCBL2
Panel
PLC
Male
DB9
2
3
7
4
5
8pin Male
Mini DIN
4
7
2
3
6
Appendix A
Connecting to a PLC
DirectTouch Panel
Appendix A
Connecting to a PLC
A16
Connecting to a PLC
Rating
Display Type
Backlit LCD
Display Colors
Display Size
5.7diagonal
Resolution
Screen Type
Resistive
Number of screens
1 MB
System Memory
512 KB
Alarms/Faults
Yes
Clock/Calendar
Password Protection
Yes
PLCs Supported
DL 105/205/305/405
AB SLC 5/03 & 5/04
Warranty
12 Months
Storage Temperature
Operating Temperature
Humidity
Vibration
Shock
Voltage
Power
Inrush Current
2.8 A
Humidity
Vibration
Communications
Maximum Distance
Withstand Voltage
NEMA Rating
Agency Approval
Atmosphere
No corrosive gases
Connecting to a PLC
A17
It is important to understand the installation requirements for our operator interfaces. Sometimes the size
alone can dictate your choice of unit. This is especially true with respect to the depth of the unit. Please make
sure you consider the space required for proper access to cables, power wiring, etc. Also, you may need to
consider the environmental requirements, agency approvals, etc. for your particular application.
Back
Side
7.402
(188 mm)
Cable Connector
RS232C
5.906
(150 mm)
FG
SG
RD
RD+
DC 24V
+ FG
Overall Dimension
DPC320
S/N 020023
5.630
(143mm)
SD
SD+
0.275
(7.0mm)
7.677
(195mm)
Overall Dimension
1.575
(40.0mm)
2.25
(57.1mm)
Top
1.85
(47.0mm)
0.275
7.0mm)
Cable Connector
Panel Cutout
Dimensions
5.650.012
(143.5 0.3mm)
2.25
(57.1mm)
7.4210.012
(188.5 0.3mm)
NOTE: For monochrome panels (DPM320 or DPM321), the System Setup >
Display Control > Brightness Setup must be set to the 5th from left (default), or
higher, in order to display properly.
Appendix A
Connecting to a PLC