Vous êtes sur la page 1sur 3

NATIONAL HIGHWAYS AUTHORITY OF INDIA

Name of the work

:-

Package
Name of the Client
Concessionaire
Name of the Consultant
Name of the Contractor

:::::-

Six laning of Panipat to Jalandhar Section of NH-1 from


Km. 096 + 000 To 387 +100 in the State of Haryana &
Punjab
PJ-02 (Km.146.000 to 212.161)
NHAI.
Soma - Isolux NH ONE Toll Way Private Limited
Louis Berger Group
Isolux Corsan India & SOMA JV.

MIXED SEAL SURFACING BLENDING


Percentage for blending

IS
SIEV
E
(mm)

12-6 mm

13.20

Total % of
Passing

MID
LIMIT

MORTH LIMIT
TABLE -500-26
Type-B

12-6 mm

6-0mm

6-0 mm

70%

30%

100.00

100.00

70.00

30.00

100.00

100.00

100

100

11.20

93.37

100.00

65.36

30.00

95.36

94.00

88

100

5.60

14.70

93.83

10.29

28.15

38.44

41.50

31

52

2.80

2.99

51.61

2.09

15.48

17.58

15.00

25

0.09

0.64

4.96

0.45

1.49

1.94

2.50

Lower Limit Upper limit

MSS BLENDING CURVE CHART


120

80

60

PASSING OF
%

100

40

20

0
0.01

0.10

Passing of %

1.00
IS SIEVE
SIZE IN MM
Lower Limit

Upper Limit

Checked by

Tested by

SOMA Representative

10.00

SPV Representative

IC Representative

100.00

NATIONAL HIGHWAYS AUTHORITY OF INDIA


Name of the work

:-

Package
Name of the Client
Concessionaire
Name of the Consultant
Name of the Contractor

:::::-

Six laning of Panipat to Jalandhar Section of NH-1 from


Km. 096 + 000 To 387 +100 in the State of Haryana &
Punjab
PJ-02 (Km.146.000 to 212.161)
NHAI.
Soma - Isolux NH ONE Toll Way Private Limited
Louis Berger Group
Isolux Corsan India & SOMA JV.

MIXED SEAL SURFACING BLENDING


Percentage for blending

IS
SIEV
E
(mm)

12-6 mm

13.20

Total % of
Passing

MID
LIMIT

MORTH LIMIT
TABLE -500-26
Type-B

12-6 mm

6-0mm

6-0 mm

65%

35%

100.00

100.00

65.00

35.00

100.00

100.00

100

100

11.20

93.37

100.00

60.69

35.00

95.69

94.00

88

100

5.60

14.70

93.83

9.56

32.84

42.40

41.50

31

52

2.80

2.99

51.61

1.94

18.06

20.01

15.00

25

0.09

0.64

4.96

0.42

1.74

2.15

2.50

Lower Limit Upper limit

MSS BLENDING CURVE CHART


120

80

60

PASSING OF
%

100

40

20

0
0.01

0.10

Column G

1.00
IS SIEVE
SIZE IN MM
Column I

Column J

Checked by

Tested by

SOMA Representative

10.00

SPV Representative

IC Representative

100.00

NATIONAL HIGHWAYS AUTHORITY OF INDIA


Name of the work

:-

Package
Name of the Client
Concessionaire
Name of the Consultant
Name of the Contractor

:::::-

Six laning of Panipat to Jalandhar Section of NH-1 from


Km. 096 + 000 To 387 +100 in the State of Haryana &
Punjab
PJ-02 (Km.146.000 to 212.161)
NHAI.
Soma - Isolux NH ONE Toll Way Private Limited
Louis Berger Group
Isolux Corsan India & SOMA JV.

MIXED SEAL SURFACING BLENDING


Percentage for blending

IS
SIEV
E
(mm)

12-6 mm

13.20

Total % of
Passing

MID
LIMIT

MORTH LIMIT
TABLE -500-26
Type-B

12-6 mm

6-0mm

6-0 mm

60%

40%

100.00

100.00

60.00

40.00

100.00

100.00

100

100

11.20

93.37

100.00

56.02

40.00

96.02

94.00

88

100

5.60

14.70

93.83

8.82

37.53

46.35

41.50

31

52

2.80

2.99

51.61

1.79

20.64

22.44

15.00

25

0.09

0.64

4.96

0.38

1.98

2.37

2.50

Lower Limit Upper limit

MSS BLENDING CURVE CHART


120

80

60

PASSING OF
%

100

40

20

0
0.01

0.10

Column G

1.00
IS SIEVE
SIZE IN MM
Column I

Column J

Checked by

Tested by

SOMA Representative

10.00

SPV Representative

IC Representative

100.00

Vous aimerez peut-être aussi