Vous êtes sur la page 1sur 24

Sustainable Modular

Filtration Systems

Sustainable Modular
Filtration Systems

Contents

Page

Page

Contents ............

FiltaCarb vent cube series technology ........................

14

Bioac2on product range structure ................................

FiltaCarb vent cube series specica2ons & standard range ..

15

FiltaOdor biolter series technology ..........................

FiltaCarb 75 series technology ..

16

FiltaOdor biolter series specica2ons & standard range ..................

FiltaCarb 75 series specica2ons & standard range ...

17

FiltaBTF biotrickling series technology .

FiltaVent passive series technology ...

18

FiltaBTF biotrickling series specica2ons & standard range

FiltaVent passive series specica2ons & standard range ..

19

FiltaPlus dual vessel series technology ...

FiltaVent two-way passive series technology ........................

20

FiltaPlus dual vessel series specica2ons & standard range .

FiltaVent two-way passive series specica2ons & standard range .

21

FiltaPlus extension vessel series technology ...

10

Bioac2on Services, R&D program and Client List ....

22

FiltaPlus extension vessel series specica2ons & standard range ..

11

Company Details ................................

23

FiltaCarb vapour phase series technology .......................

12

FiltaCarb vapour phase series specica2ons & standard range

13

Glossary

VOCs : Vola2le Organic Compounds

DVS : German Welding Society standards supplied through DVS Media

HDPE : High Density Polyethylene

WWPS : Waste Water Pump Sta2on

PVC : Polyvinyl Chloride

PS : Pump Sta2on

UPVC : Unplas2cised Poly Vinyl Chloride

PLC : Programmable Logic Controller

H2S : Hydrogen Sulphide

UV : Ultraviolet Light

EBRT : Empty Bed Residence Time

OCU : Odour Control Unit

GAC : Granular Ac2vated Carbon

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems
BIOLOGICAL SYSTEMS


ORGANIC MEDIA

ADSORPTION SYSTEMS

ACTIVATED CARBON
MEDIA

SPECIALISED
ADSORPTION MEDIA


DUAL VESSEL SERIES

SINGLE VESSEL
SERIES

GROUND MOUNTED
VENT SERIES

EXTENSION VESSEL
SERIES


CUBE SERIES

2 WAY GROUND
MOUNT VENT SERIES


INORGANIC MEDIA

DUAL TREATMENT
TRAIN

The!use!of!advanced!bio0engineering!and!biological!digestion!ensures!air!
phase!contaminates!are!destroyed!in!the!most!complete!and!environmentally!
safe!manner.!
BioMedia!Organic!Media!is!made!from!one!of!the!most!renewable!media!
available.!There!are!no!chemical!inputs!in!the!growing,!processing!and!use.!It!
can!be!returned!to!the!earth!as!an!enhanced!growing!media.!
Bioaction!filtration!systems!are!designed!and!engineered!to!minimise!our!
carbon!footprint.!They!have!low!energy!requirements!and!are!highly!freight!
efficient!to!reduce!transport!movements.!!


75 CANISTER SERIES

Over!90%!of!the!materials!used!in!construction!and!filter!media!can!be!
recycled!for!after0life!use.!
!

MEDIA SUPPLIES

Bioac<on ltra<on systems are available as packaged systems


or custom project driven designs

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems
About FiltaOdorTM biolter technology

Benets of FiltaOdorTM biological odour lters:

FiltaOdorTM biological lter systems use a homogeneous organic


micropore ltra2on media derived from a highly renewable resource.
The media has high adsorp2ve proper2es for ecient mass transfer of
organics and oxygen from inlet gases into the liquid phase. It is long
las2ng with a high mechanical stability, has low bioavailability and a
high surface area to volume ra2o. This excep2onally large
surface area and rough porous surface permits bacteria adhesion to
promote biomass colonisa2on and distribu2on. Its porosity prevents
pressure loss and maintains constant aerobic condi2ons throughout
the life of the media. The life expectancy of the organic media is
greater than 10 years delivering an excellent return on investment.

FiltaOdorTM biolter series represents the latest technology in


deep bed bioltra3on for the control of odourous sewer and
industry gases.

The environment created by the media enables the highly ecient


treatment of odorous gases to reduce the odour proles of Hydrogen
Sulphide (H2S), mercaptans, VOCs, hydrocarbons, ketones, aldehydes,
amines and reduce sulphide gases such as Dimethyl Sulphide. Once
the system is opera2onal there is minimal maintenance required,
provided the supply of the connected u2li2es of water, power and
drainage are stable.

Suitable for municipal sewer and industrial applica2ons


Capable of removing greater than 95% of H2S
Ability to treat complex gas streams
More than 10 years life expectancy from the unique organic
media.
Deep-bed design with minimal sta2c pressure
Small opera2ng footprint
High reten2on 2mes
Corrosion resistant and UV stable HDPE construc2on
Complete with blower, irriga2on, humidica2on system and
electrical control panel
Skid mounted for rapid deployment and ease of transport
Minimal installa2on (air, water, waste and power)

The FiltaOdorTM lter system is available in a number of standard


capaci2es ranging from 75 L/s to 670 L/s and Bioac2on is happy to
consult on custom requirements. Custom congura2on of odour
abatement solu2ons includes design and development of systems to
deal with specic capacity and installa2on requirements as well as
more complex odorous gas proles.

FiltaOdorTM FO300 with a FiltaVentTM two-way passive lter in foreground installed for
Cos City Council WWPS.

The plugnplay modular design of Bioac2ons FiltaOdorTM lter system


provides total exibility in designing the system to suit the target ow
requirements and emission reduc2on outcomes. The modular design
also enables it to be posi2oned in rela2vely constrained spaces in
comparison to other systems. The modular design is constructed on
an engineered skid base to enable rapid installa2on and
commissioning, typically within 1-3 days of delivery to site.
FiltaOdorTM Biolter installed for Cairns Regional Council WWPS

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems

Adsorptive Media

FiltaOdorTM uses a unique hydrophobic micropore ltra2on media with high adsorp2ve proper2es for ecient mass transfer of
organics and oxygen from inlet gases into the liquid phase. This highly robust media has an excep2onally large surface area for
biomass distribu2on and is suciently porous to prevent high pressure loss.

Humidification and
Irrigation

A humidica2on chamber is located prior to the inlet of the lter plenum. Mis2ng sprayers are located in the chamber to saturate
untreated gas to >95% rela2ve humidity. The lter bed is irrigated to maintain correct moisture levels within the lter media to
op2mise biomass stability and colonisa2on. The irriga2on assembly is located on the lter bed surface and accessed through the
inspec2on hatch.

Optional Items

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Irriga2on and inspec2on hatch access
plamorm. Con2nuous H2S monitoring. Ac2vated carbon secondary polisher.

Media
Volume

Media
Depth

Duct Size

Pressure
Drops

Biofilter
(m)

Width C
(m)

Length D
(m)

Biofilter
Vessel A
(m)

Misc.
(Skid,
Duct etc.)

Total B
(m)

Bio Filter
(m3)

Biofilter
(m)

Biofilter
Media (kg)

Vessel
(kg)

Skid (kg)

Misc. (kg)

Total (kg)

(mm) ID

Vessel
(Pa)

Model

Motor
Size (kW)

270

30

1.2

1.8

3.0

2.86

0.66

3.52

2.25

788

133

170

100

1191

104

600

Seat 15

0.37

FO165

165

594

30

1.8

1.8

3.0

2.94

0.66

3.60

4.95

1733

228

300

105

2366

154

600

Seat 20

1.10

FO300

300

1080

30

2.4

2.4

4.0

3.00

0.66

3.66

9.00

3150

337

420

120

4027

240

600

Seat 20

1.10

FO450

450

1620

30

3.0

3.0

4.5

3.08

0.66

3.74

13.50

4725

449

576

150

5900

300

600

Seat 25

2.20

FO670

670

2412

30

3.6

3.6

4.8

3.16

0.66

3.82

20.10

7035

589

690

200

8514

375

600

Seat 25

2.20

System
Heights

System
Mass

Vessel
Outside
Diameter

Biofilter
(sec)

75

Skid Size

Empty Bed
Residence
Time
(EBRT)
m3 / hr.

FO75

Capacity
L/s

Fan Details

Construction

FiltaOdorTM lter vessels are constructed from P300 HDPE, incorpora2ng impregnated resins that are corrosion resistant and UV
stabilised throughout the material. They have a high chemical-resistance to provide signicant design life expecta2on and are
suitable for all clima2c condi2ons. Construc2on follows DVS technical codes on plas2c joining DVS 2202 / 2210. Joint construc2on is
bul and extrusion welded.

Model

Series
FiltaOdorTM

Functional Description

The FiltaOdorTM system is a biological treatment system which is capable of removing greater than 95% of odours. A fan on the
exhaust side of the vessel creates nega2ve pressure to ensure air ow across the system. Hazardous gases in the incoming air move
through a humidica2on system to raise the rela2ve humidity to > 95%. The gas diuses through the moist organic media lter bed
where the contaminants are biologically oxidised. Moisture within the lter bed is maintained and controlled by an irriga2on system.
Treated air then ows through a vent stack and out to atmosphere.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems
FiltaBTFTM biotrickling series biological air phase
ltra3on system for the control of odourous sewer
and industry gases.

Removable lid

Irriga3on/Transi3on

Media

Wet Well

About FiltaBTFTM biotrickling technology

Benets of FiltaBTFTM biotrickling ltra<on systems:


The FiltaBTFTM biotrickling lter is part of the Bioac2on biological
air phase odour and emission lter range. These biological
scrubbers or biotricklers oer a very eec2ve way to treat high
levels of odorous and pollutant gases such as Hydrogen Sulphide
(H2S), mercaptans and VOCs. This natural process of biological
oxidisa2on can achieve signicant odour and emission reduc2on
in outlets with high gas concentra2ons, without the use of harsh
chemicals.

FiltaBTFTM biotrickling lters are a modular plugnplay lter
system and can be congured in a mul2ple vessel or low-rise
construc2on to achieve most treatment outcomes and
installa2on requirements. Depending on the site, by installing a
low-rise system with a large diameter vessel over a larger area
the duplica2on of pipe and system infrastructure associated with
tall mul2-vessel system is negated and the cost savings are
signicant. The modular design minimises costs via a reduc2on
in construc2on lead-2mes as well as logis2cs costs and on site
assembly costs. All the lter vessels are constructed in Australia
from HDPE to meet strict wastewater guidelines. They are
designed to minimise UV degrada2on by using UV stabilised
materials.

FiltaBTFTM biotrickling ltra2on systems have a great value
proposi2on and meet expecta2ons for the environmentally
sustainable treatment of gaseous pollutants from industries such
as municipal and industrial waste water treatment, sewer
systems and pump sta2ons, pulp & paper industries, tanneries,
rendering facili2es, minerals and petrochemical processing,
landlls, and compos2ng plants.

Suitable for municipal sewer and industrial applica2ons


Hydrogen Sulphide removal rates of up to 99%
Modular robust construc2on
Ecient water usage
Unique nutrient makeup
Small footprint
Flexible design to suit height or surface area restric2ons
Low environmental impact

FiltaBTFTM FV580 x 2 System with secondary carbon lter

FiltaBTFTM BTF580

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems

Functional Description

The FiltaBTFTM system is a biological treatment system capable of removing up to 99% of odours. Hazardous gases are
extracted from the source using a blower/extrac2on fan and air is forced through a packed bed of inorganic media. The gas
diuses through the media lter bed which is con2nually moistened by an irriga2on system. Nutrient is provided by the
irriga2on system to promote microorganism growth on the lter media which metabolise the contaminated air stream. Water
to the irriga2on can be recirculated from the wet well and pH balanced. Nutrient supply can be supplemented by recycled
euent water if available.

Construction

FiltaBTFTM lter vessels are constructed from P300 HDPE, incorpora2ng impregnated resins that are corrosion resistant and UV
stabilised throughout the material. They have a high chemical-resistance to provide signicant design life expecta2on and are
suitable for all clima2c condi2ons. Construc2on follows DVS technical codes on plas2c joining DVS 2202 / 2210. Joint
construc2on is bul and extrusion welded.

Adsorptive Media

The packed bed media is either PVC pal rings or open cell foam blocks, each designed to provide a large surface area for
biological adhesion and minimise pressure drop.

Humidification and
Irrigation

The lter bed is irrigated to maintain correct moisture levels within the lter media to op2mise biomass stability and
colonisa2on. The irriga2on assembly is located on the lter bed surface and accessed through the inspec2on hatch.

Optional Items

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Irriga2on and inspec2on hatch
access plamorm. Con2nuous H2S monitoring. Ac2vated carbon secondary polisher

GAC
(sec)

Biofilter
(m)

GAC
(m)

Width (m)

Length (m)

Biofilter
Vessel (m)

GAC Vessel
(m)

Misc.
(Skid, Duct,
etc.) (m)

Total Height
(m)

Biofilter (m3)

GAC (m3)

Biofilter (m)

GAC (m)

Biofilter
Media (kg)

GAC Media
(kg)

Vessels (kg)

Skid (kg)

Misc. (kg)

Total (kg)

Duct (mm)
ID

Vessel (Pa)

Model

Motor Size
(kW)

2088

15

N/A

2.3

N/A

2.3

4.3

5.2

N/A

0.16

5.39

8.7

N/A

2.13

N/A

861

N/A

661

415

500

2437

300

100

Seat
25

2.20

580

2088

15

3.0

2.3

1.8

2.3
+
2.4

4.3
+
4.0

5.2

2.56

0.16

5.39

8.7

1.7

2.13

0.61

861

974

1004

835

600

4274

300

620

Seat 25

Fan
Details

Pressure
Drops

Biofilter
(sec)

Duct
Sizing

System
Mass

m3 / hr.

Media
Depth

Media
Volume

System
Heights

Skid Size

L/s

Vessel
Outside
Diameter

Model
FB580

580

FB580H

FiltaBTF

Series

Capacity

Empty
Bed
Residence
Time
(EBRT)

FiltaBTFTM BTF580H

2.20

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems
About FiltaPlusTM odour control technology

FiltaPlusTM dual vessel series bioltra3on systems use a


combina3on of biological and carbon ltra3on technologies
for the control of odourous sewer and industry gases.

Benets of FiltaPlusTM odour control lters:

FiltaPlusTM hybrid biolters provide the highest level of emission and


odour abatement. The two-stage treatment train complements the
latest technology in deep bed bioltra2on emission and odour
treatment. The system consists of a rst stage bioltra2on vessel
followed by a second stage carbon ltra2on vessel.

This highly engineered, ecient, low maintenance and cost-eec2ve


odour control system is designed to reduce odorous emissions by over
99.5%. Addi2onally it can reduce corrosion of sewer infrastructure.

The dual vessel congura2on uses separate vessels for the biological
and carbon ltra2on components of the process. Depending on site
space restric2ons and ow requirements, the dual vessel design can
be more cost eec2ve than other solu2ons.

Suitable for municipal sewer and industrial applica2ons


More than 99.5% of H2S removed
More than 10 years biolter life expectancy from the unique long
las2ng media.
Deep-bed design with minimal sta2c pressure
Compact design and small opera2ng footprint
High reten2on 2mes
Corrosion resistant and UV stable HDPE construc2on
Complete with blower, irriga2on, humidica2on system and
electrical control panel
Minimal installa2on (air, water, waste and power)

The custom congura2on of media composi2on within the separate


vessels enables Bioac2ons experts to reduce odour proles by more
than 99.5% of Hydrogen Sulphide (H2S). If a gas prole exists for
mul2ple fugi2ve odourous gases that need to be removed, Bioac2on
can formulate mixtures of media to deal with high levels of other
odorous gases such as Ammonia, Mercaptans and Dimethyl Sulphide.
VOCs can also be addressed in these systems as part of the media
composi2on mixture to give an extremely good end result.

FiltaPlusTM FP670 system built for Flow Systems at Wyee NSW

Bioac2ons experts will assess the odour prole for any given site and
propose a mix of homogeneous organic micropore ltra2on media
derived from a highly renewable resource and combina2ons of carbon
media in the form of granular vapour carbon and caus2c
impregnated vapour carbon.

FiltaVent FV120 System with 4 x Cart30 Cartridges loaded.

The modular design of Bioac2ons FiltaPlusTM enables it to be


posi2oned in rela2vely constrained spaces in comparison to other
systems. The modular design is constructed on an engineered skid
base to enable rapid installa2on and commissioning, typically within
1-3 days of delivery to site.

FiltaPlusTM FP300 x 2 system built for S.A. Water Wingeld WWPS

FiltaPlusTM rapid installa2on via delivery of precongured units on engineered galvanised skids

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Adsorptive Media

FiltaPlusTM uses a unique hydrophobic micropore ltra2on media with high adsorp2ve proper2es for ecient mass transfer of organics
and oxygen from inlet gases into the liquid phase. This highly robust media has an excep2onally large surface area for biomass
distribu2on and is suciently porous to prevent high pressure loss.
The secondary vessel uses specically designed ac2vated carbon for use in odour control systems where the primary cause of odour is as
a result the presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to
meet any needs that fall outside the capaci2es of our standard ac2vated carbon materials.

Humidification and
Irrigation

A humidica2on chamber is located prior to the inlet of the lter plenum. Mis2ng sprayers are located in the chamber to saturate
untreated gas to >95% rela2ve humidity. The lter bed is irrigated to maintain correct moisture levels within the lter media to op2mise
biomass stability and colonisa2on. The irriga2on assembly is located on the lter bed surface and accessed through the inspec2on hatch.

Optional Items

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Irriga2on and inspec2on hatch access
plamorm. Con2nuous H2S monitoring

GAC
(sec)

Biofilter
(m)

GAC
(m)

Width C
(m)

Length D
(m)

Biofilter
Vessel A
(m)

GAC
Vessel
(m)

Misc.
(Skid,
Duct,
etc.) (m)

Total
Height B
(m)

Biofilter
( m3 )

GAC
( m3 )

Biofilter
(m)

GAC (m)

Biofilter
Media
(kg)

GAC
Media
(kg)

Vessels
(kg)

Skid (kg)

Misc. (kg)

Total (kg)

Duct
(mm) ID

Vessels
(Pa)

Model

Motor
Size (kW)

FP75D

75

270

30

3.0

1.2

0.75

1.8
+
1.0

3.0
+
1.5

2.66

1.06

0.16

2.82

2.25

0.1

2.06

0.32

788

75

146

190

165

1364

104

1421

Seat 15

0.37

FP165D

165

594

30

3.0

1.8

1.0

1.8
+
1.0

3.0
+
2.2

2.74

1.78

0.16

2.90

4.95

0.5

1.99

0.62

1733

260

316

500

220

3029

154

1108

Seat 20

1.10

FP300D

300

1080

30

3.0

2.4

1.2

2.4
+
1.2

4.0
+
3.0

2.80

2.18

0.16

2.96

9.00

0.7

2.02

0.62

3150

378

457

620

290

4895

240

1114

Seat 20

1.10

FP450D

450

450

30

3.0

3.0

1.5

3.0
+
1.5

4.5
+
3.0

2.88

2.22

0.16

3.04

13.5

1.1

1.94

0.61

4725

588

618

831

310

7072

300

1111

Seat 25

2.20

FP670D

670

2412

30

3.0

3.6

1.8

3.6
+
1.8

4.8
+
3.0

2.96

2.38

0.16

3.12

20.1

1.5

2.00

0.61

3150

857

808

990

330

10019

300

1120

Seat 25

Fan
Details

Biofilter
(sec)

Duct
Sizing

m3 / hr.

Media
Depth

Media
Volume

System
Heights

L/s

Vessel
Outside
Diameter

Pressure
Drops

FiltaPlusTM lter vessels are constructed from P300 HDPE, incorpora2ng impregnated resins that are corrosion resistant and UV stabilised
throughout the material. They have a high chemical -resistance to provide signicant design life expecta2on and are suitable for all
clima2c condi2ons. Construc2on follows DVS technical codes on plas2c joining DVS 2202 / 2210. Joint construc2on is bul and extrusion
welded.

System
Mass

Construction

Skid Size

Functional Description

The FiltaPlusTM system is a two stage treatment system which is capable of removing greater than 99.5% of odours. A fan on the exhaust
side of the vessel creates nega2ve pressure to ensure air ow across the system. Hazardous gases in the incoming air move through a
humidica2on system to raise the rela2ve humidity to > 95%. The gas then diuses through the moist organic media lter bed where the
contaminants are biologically oxidised. Moisture within the lter bed is maintained and controlled by an irriga2on system. Treated air
then ows through a secondary carbon vessel where a specic ac2vated carbon media mixture is used to treat the target gases to
achieve more than 99.5% removal of source gases. Treated air then ows through a vent stack and out to atmosphere.

Model

FiltaPlusTM

Dual
Vessel
Series

Capacity

Empty
Bed
Residence
Time
(EBRT)

Sustainable Modular
Filtration Systems

2.20

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Sustainable Modular
Filtration Systems
FiltaPlusTM extension vessel series bioltra3on systems use a
combina3on of biological and carbon ltra3on technologies
for the control of odourous sewer and industry gases.

About FiltaPlusTM odour control technology

Benets of FiltaPlusTM odour control lters:

FiltaPlusTM hybrid biolter provide the highest level of emission and


odour abatement. The two-stage treatment train complements the
latest technology in deep bed bioltra2on emission and odour
treatment. The system consists of a rst stage bioltra2on vessel
followed by a second stage carbon ltra2on vessel.

This highly engineered, ecient, low maintenance and cost-eec2ve


odour control system designed to reduce odorous emissions by over
99.5%. Addi2onally it can reduce corrosion of sewer infrastructure.

The dual vessel congura2on uses separate vessels for the biological
and carbon ltra2on components of the process. Depending on site
space restric2ons and ow requirements, the dual vessel design can
be more cost eec2ve than other solu2ons.

Suitable for municipal sewer and industrial applica2ons


More than 99.5% of H2S removed
More than 10 years life expectancy from the unique long las2ng
media.
Deep-bed design with minimal sta2c pressure
Compact design and small opera2ng footprint
High reten2on 2mes
Corrosion resistant and UV stable HDPE construc2on
Complete with blower, irriga2on, humidica2on system and
electrical control panel
Minimal installa2on (air, water, waste and power)

The custom congura2on of media composi2on within the separate


vessels enables Bioac2ons experts to reduce odour proles by more
than 99.5% of Hydrogen Sulphide (H2S). If a gas prole exists for
mul2ple fugi2ve odourous gases that need to be removed, Bioac2on
can formulate mixtures of media to deal with high levels of other
odorous gases such as Ammonia, Mercaptans and Dimethyl Sulphide.
VOCs can also be addressed in these systems as part of the media
composi2on mixture to give an extremely good end result.

Bioac2ons experts will assess the odour prole for any given site and
propose a mix of homogeneous organic micropore ltra2on media
derived from a highly renewable resource and combina2ons of carbon
media in the form of granular vapour carbon and caus2c
impregnated vapour carbon.

FiltaPlusTM FP300E system built for Eurobodalla Shire Council Surf Beach WWPS

The modular design of Bioac2ons FiltaPlusTM enables it to be


posi2oned in rela2vely constrained spaces in comparison to other
systems. The modular design is constructed on an engineered skid
base to enable rapid installa2on and commissioning, typically within
1-3 days of delivery to site.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

FiltaPlusTM FP3000 Gosford City Council concept Erina syphon

10

Sustainable Modular
Filtration Systems

Pressure
Drops

GAC
Vessel (m)

Misc.
(Skid,
Duct, etc.)
(m)

Total
Height B
(m)

Biofilter
(m3)

(m3)
GAC

Biofilter
(m)

GAC (m)

Biofilter
Media (kg)

GAC
Media
(kg)

Vessel
(kg)

Skid (kg)

Misc. (kg)

Total (kg)

Duct (mm)
ID

Vessels
(Pa)

Model

Motor
Size (kW)

30

3.0

1.2

0.75

1.8

3.0

2.86

0.40

0.66

3.92

2.25

0.2

2.06

0.21

788

126

153

170

165

1402

104

720

Seat 15

0.37

FP165E

165

594

30

3.0

1.8

1.0

1.8

3.0

2.94

0.45

0.16

3.55

4.95

0.5

1.99

0.20

1733

277

263

300

220

2792

154

717

Seat 20

1.10

FP300E

300

1080

30

3.0

2.4

1.2

2.4

4.0

3.00

0.50

0.16

3.66

9.00

0.90

2.02

0.20

3150

504

387

420

290

4751

240

720

Seat 20

1.10

Media
Depth

Media
Volume

Vessel
Outside
Diameter

Capacity

System
Heights

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Fan Details

Duct Sizing

Biofilter
Vessel A
(m)

270

System
Mass

Length D
(m)

75

Skid Size
Width C
(m)

FP75E

Empty Bed
Residence
Time
(EBRT)

GAC
(m)

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Irriga2on and inspec2on hatch access
plamorm. Con2nuous H2S monitoring

Biofilter
(m)

Optional Items

GAC
(sec)

A humidica2on chamber is located prior to the inlet of the lter plenum. Mis2ng sprayers are located in the chamber to
saturate untreated gas to >95% rela2ve humidity. The lter bed is irrigated to maintain correct moisture levels within the lter
media to op2mise biomass stability and colonisa2on. The irriga2on assembly is located on the lter bed surface and accessed
through the inspec2on hatch.

Biofilter
(sec)

Humidification and
Irrigation

m3 / hr.

Adsorptive Media

FiltaPlusTM uses a unique hydrophobic micropore ltra2on media with high adsorp2ve proper2es for ecient mass transfer of
organics and oxygen from inlet gases into the liquid phase. This highly robust media has an excep2onally large surface area for
biomass distribu2on and is suciently porous to prevent high pressure loss. The secondary vessel uses specically designed
ac2vated carbon for use in odour control systems where the primary cause of odour is as a result the presence of mercaptans,
Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to meet any needs that fall outside
the capaci2es of our standard ac2vated carbon materials.

L/s

Construction

FiltaPlusTM lter vessels are constructed from P300 HDPE material, which is made from impregnated resins that are corrosion
resistant and UV stabilised throughout the material. They have a high chemical-resistance to provide signicant design life
expecta2on and are suitable for all clima2c condi2ons. Construc2on follows DVS technical codes on plas2c joining DVS 2202 /
2210. Joint construc2on is bul and extrusion welded.

Model

Extension
Vessel
Series
FiltaPlusTM

Functional Description

The FiltaPlusTM system is a two stage treatment system which is capable of removing greater than 99.5% of odours. A fan on the
exhaust side of the vessel creates nega2ve pressure to ensure air ow across the system. Hazardous gases in the incoming air
move through a humidica2on system to raise the rela2ve humidity to > 95%. The gas then diuses through the moist organic
media lter bed where the contaminants are biologically oxidised. Moisture within the lter bed is maintained and controlled by
an irriga2on system. Treated air then ows through the carbon extension where a specic ac2vated carbon media mixture is
used to treat the target gases to achieve more than 99.5% removal of source gases. Treated air then ows through a vent stack
and out to atmosphere.

11

Sustainable Modular
Filtration Systems
FiltaCarbTM vapour phase series ac3vated carbon ltra3on
systems for the control of odourous sewer and industry gases.

About FiltaCarbTM carbon lter technology



FiltaCarbTM vapour phase ac2vated carbon systems provide an
ecient and economical means to reduce VOC concentra2ons,
corrosive gases including Hydrogen Sulphide (H2S) and toxic vapours
to control odours. They provide immediate adsorp2on upon contact
with the gases. All of the systems have a specied contact 2me to
ensure they meet op2mum performance throughout the life of the
media. The lter vessels are lled with a specic granular ac2vated
carbon, which is suitable for a variety of odour abatement
applica2ons.

Benets of FiltaCarbTM odour control lters:

Suitable for municipal sewer and industrial applica2ons


More than 99.5% of H2S removed
Op2mum use of media through lter vessel design
Minimal pressure loss across the lter bed
Very small opera2ng footprint
High contact 2me within the lter bed
Corrosion resistant and UV stable HDPE construc2on
Complete with blower and electrical control panel
Skid mounted
Minimal installa2on (air and power)

The FiltaCarbTM range of lter systems can meet any ow requirement


and range in size from small lter drum designs through to large 3.6m
diameter HDPE vessels. They can also be arranged in parallel to
accommodate higher ow rates. All the lters are designed for the
ecient use of the ac2vated carbon in the bed while maintaining a
low pressure drop to reduce loading on the blower and maximise its
life

The plugnplay modular design of Bioac2ons FiltaCarbTM lter


systems provide total exibility in designing the system to suit the
target ow requirements and emission reduc2on outcomes. The
modular design also enables it to be posi2oned in rela2vely
constrained spaces in comparison to other systems. The modular
design is constructed on an engineered skid base to enable rapid
installa2on and commissioning, typically within 1-3 days of delivery to
site.

FiltaCarbTM FC350 system built for Sydney Water Corpora2on Douglas Park
storage tank

The congura2on of media composi2on within the system enables


Bioac2ons experts to reduce odour proles by more than 99.5% of
Hydrogen Sulphide (H2S). They can also address complex industrial
gases and target reduc2on outcomes to determine system design and
the type of adsorp2on media.
FiltaCarbTM FC510 standard skid mounted system

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

12

Sustainable Modular
Filtration Systems

Duct
Size

Pressure
Drops

GAC
(m)

GAC
Media
(kg)

Vessel
(kg)

Skid
(kg)

Misc.
(kg)

Total
(kg)

(mm) ID

Vessel
(Pa)

Model

Motor
Size
(KW)

1.5

2.4

1.78

0.16

1.94

0.47

0.62

260

88

200

105

653

154

508

Seat 20

1.10

1.2

1.6

2.4

2.18

0.16

2.34

0..68

0.62

378

120

200

130

828

240

514

Seat 20

1.10

Skid
Size

Empty
Bed
Residen
ce Time
(EBRT)
/ hr.
m3

L/s

Fan
Details

Media
Depth

GAC
( m3 )

1.0

System
Mass

Media
Volume
Total B
(m)

810

System
Heights
Misc.
(Skid,
Duct)

558

225

Vessel
Outside
Dia.

155

FC225

Capacity

Vessel
A (m)

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Inspec2on hatch access plamorm.
Con2nuous Hydrogen Sulphide (H2S) monitoring.

Length
D (m)

Optional Items

Width C
(m)

U2lises a specically designed ac2vated carbon for use in odour control systems where the primary cause of odour is as a result the
presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to meet any
needs that fall outside the capaci2es of our standard ac2vated carbon materials.

(m)

Adsorptive Media

(sec)

Construction

FiltaCarbTM vessels are constructed from P300 HDPE, incorpora2ng impregnated resins that are corrosion resistant and UV
stabilized throughout the material. They have a high chemical-resistance to provide signicant design life expecta2on and are
suitable for all clima2c condi2ons. Construc2on follows DVS 2202 / 2210 technical codes on plas2c joining. Joint construc2on is
bul-welded and extrusion welded.

FC155

Model

Series
FiltaCarbTM

Functional Description

The FiltaCarbTM system is a single-stage treatment using carbon adsorp2on technology. Hazardous gases are extracted from the
source using an extrac2on/blower fan that then vents the untreated gases through the lter media. The untreated gases
accumulate in the lower plenum of the lter before being evenly diused through the media of the lter bed where contaminates
are physically adsorbed. A specic ac2vated carbon media mixture is used to treat the target gases to achieve more than 99.5%
removal of source gases.

FC350

350

1260

1.5

1.6

3.0

2.22

0.16

2.38

1.05

0.61

588

169

255

135

1147

240

511

Seat 20

1.10

FC510

510

1836

1.8

1.8

3.0

2.38

0.16

2.54

1.53

0.61

857

219

300

160

1535

300

520

Seat 25

2.20

FC900

900

3240

2.4

2.4

4.0

2.56

0.16

2.72

2.70

0.61

1512

343

420

200

2475

375

514

Seat 35

5.50

FC1400

1400

5040

3.0

3.0

4.8

2.75

0.16

2.91

4.20

0.60

2352

478

576

350

3765

500

511

Seat 35

5.50

FC1900

1900

6840

3.6

3.6

4.8

3.01

0.16

3.17

5.70

0.57

3192

692

690

380

4954

500

470

Seat 35

5.50

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

13

Sustainable Modular
Filtration Systems
FiltaCarbTM vent cube series vapour phase ac3vated carbon
ltra3on systems for the control of odourous sewer gases.

About FiltaCarbTM carbon lter technology

Benets of FiltaCarbTM vent cube lters:

FiltaCarbTM vapour phase ac2vated carbon systems provide an


ecient and economical means to reduce VOC concentra2ons,
corrosive gases including Hydrogen Sulphide (H2S) and toxic vapours
to control odours. They provide immediate adsorp2on upon contact
with the gases. All of the systems have a specied contact 2me to
ensure they meet op2mum performance throughout the life of the
media. The lter vessels are lled with a specic granular ac2vated
carbon, which is suitable for a variety of odour abatement
applica2ons.

The FiltaCarbTM vent cube oers a simple and secure solu2on for
fugi2ve odours from pump sta2ons. The system can be mounted
directly above a penetra2on into the wet well or mounted locally and
ducted to the system. The system is supplied complete with extrac2on
fan and sound alenuator. The vent cube has a robust construc2on
with high durability and is UV and corrosion resistant.

Suitable for municipal sewer applica2ons


More than 99.5% of H2S removed
Comes complete with fan and ow control dampener
Quick and simple installa2on
Only requires power
Eec2ve treatment to remove a variety of organic contaminants
and odour-causing emissions
Con2nuous treatment at varying ow rates and concentra2ons
Low pressure drops across the lter bed
Mul2ple units can be installed in series or in parallel
Low cost per unit makes carbon treatment economical
Designed for the rigors of wastewater treatment

Suitable for wastewater pump sta2ons, rising mains and manholes. It


is also suitable for other industrial emission applica2ons where
specic ltra2on media can be applied to treat the target emissions.

All FiltaCarbTM vent cube models have incorporated into their design
a fats and greases pre-lter to maintain constant air pressure and
increase the life of the carbon media. This pre-lter also makes the
system easier to maintain as it can be cleaned as oten as necessary.

Unlike passive lters and vents, the forced extrac2on of the


FiltaCarbTM vent cube provides a controlled rate of extrac2on. This
enables beler opera2onal management of the fugi2ve and poten2ally
corrosive gases.

FiltaCarbTM FCC150 cube series lter built for Hunter Water Corpora2on Corlele WWPS

FiltaCarbTM FCC200F cube series lter

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

14

Sustainable Modular
Filtration Systems

Optional Items

An electrical control panel, which can be mounted to the skid for local control, with manual ON/OFF/AUTO switch opera2on and
indicator lights to show opera2onal status. Control panel powder coated steel - IP65 rated or op2onal stainless steel - IP65 rated.
Break-through gas indicators

Duct Size

Pressure
Drops

(m)

GAC (kg)

Vessel
(kg)

Misc. (kg)

Total (kg)

(mm) ID

Vessel
(Pa)

Model

Motor Size
(KW)

1.69

0.45

0.57

252

78

30

360

154

341

Seat 20

1.10

200

540

1.14

1.55

1.77

0.60

0.60

336

198

30

564

154

577

Seat 20

1.10

hr.

Media
Mass

System
Mass

(m3)

1.30

Media
Depth

Vessel A
(m)

1.00

Media
Volume

Length D
(m)

System
Heights

Width C
(m)

Empty Bed
Residence
Time
(EBRT)
540

Capacity

(sec)

Fan Details

U2lises a specically designed ac2vated carbon for use in odour control systems where the primary cause of odour is as a result of
the presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to meet
any needs that fall outside the capaci2es of our standard ac2vated carbon materials.

Vessel Size

Adsorptive Media

m3 /

FCC200

Construction

FiltaCarbTM vent cube ac2vated carbon lter is designed to reduce logis2c and installa2on costs. The system is preloaded with
media and is factory tested prior to dispatch. The lter vessel as well as any other associated components (including extrac2on fan
and sound alenuator) are mounted within a single assembly. The FiltaCarbTM cube vent lter is constructed from PVC which has
been constructed to be corrosion and UV resistant. Op2onal: HDPE.

150

L/s

Model

Cube
Series
FiltaCarb

FCC150

Functional Description

The FiltaCarbTM system is a single-stage treatment using carbon adsorp2on technology. A fan on the exhaust side of the vessel
creates nega2ve pressure to ensure air ow across the system. Hazardous gases in the incoming air move through a pre-lter to
capture fats and greases and then move through the lter media. The untreated gases accumulate in the lower plenum of the lter
before being evenly diused through the media of the lter bed where contaminates are physically adsorbed. A specic ac2vated
carbon media is used to treat the target gases to achieve more than 99.5% removal of source gases.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

15

Sustainable Modular
Filtration Systems
FiltaCarbTM 75 series canister vapour phase ac3vated carbon
ltra3on systems for the control of odourous sewer and
industry gases.

About FiltaCarbTM carbon lter technology

Benets of FiltaCarbTM 75 series lters:


FiltaCarbTM vapour phase ac2vated carbon systems provide an
ecient and economical means to reduce VOC concentra2ons,
corrosive gases including Hydrogen Sulphide (H2S) and toxic vapours
to control odours. They provide immediate adsorp2on upon contact
with the gases. All of the systems have a specied contact 2me to
ensure they meet op2mum performance throughout the life of the
media. The lter vessels are lled with a specic granular ac2vated
carbon, which is suitable for a variety of odour abatement
applica2ons.

FiltaCarbTM 75 series vapour carbon canisters, each containing 75kg of
ac2vated carbon, are ideal for low-ow air purica2on for industrial
and municipal applica2ons. These budget adsorp2on lters are
specically designed for wastewater and acid gas emissions but they
are also suitable for a range of industrial gases.

The Bioac2on FiltaCarbTM lter series provides total exibility in
designing a system to suit the target ow requirements and emission
reduc2on outcomes. They are par2cularly well suited to:

Sewer vents, wet sta2ons and weir boxes at chemical and
municipal wastewater treatment plants.
Sewer pump sta2ons
Sewer wet wells
Inlet works
Storage Tanks
Other acid emission sources

Suitable for municipal sewer and industrial applica2ons


More than 99.5% of H2S removed
Eec2ve treatment to remove a variety of organic contaminants
and odour-causing emissions
Con2nuous treatment at varying ow rates and concentra2ons
Low pressure drops across the lter bed
Simple installa2on and opera2on
Flexibility to be installed in series or mul2ple units in parallel
Low cost per unit makes carbon treatment economical
Designed for the rigors of wastewater treatment
Rapid drum replacement when carbon is depleted

FiltaCarbTM FC75x3

FiltaCarbTM FC75x1

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

16

Sustainable Modular
Filtration Systems

Pressure
Drops

(m3)

(m)

GAC
Media
(kg)

Drum
(kg)

Skid
(kg)

Misc.
(kg)

Total
(kg)

(mm)
ID

Vessel
(Pa)

Model

Motor
Size
(KW)

0.59

0.85

1.20

1.06

0.68

1.74

0.13

0.52

75

13

20

100

208

100

821

Seat 15

0.37

FC75x2

150

540

1.8

0.59

0.85

1.80

1.06

1.15

2.21

0.27

0.52

150

26

29

100

305

154

821

Seat 20

1.10

FC75x3

225

810

1.8

0.59

0.85

2.40

1.06

1.21

2.27

0.40

0.52

225

38

39

100

102

154

821

Seat 20

1.10

FC75

75

270

1.8

0.59

N/A

N/A

1.06

N/A

1.06

0.13

0.52

75

13

N/A

N/A

88

100

821

N/A

N/A

FC75SS

75

270

1.8

0.59

N/A

N/A

1.06

N/A

1.06

0.13

0.52

75

25

N/A

N/A

100

100

821

N/A

N/A

hr.

Media
Depth

Media
Volume

Vessel
Outside
Dia.

Capacity
L/s

System
Heights

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

Fan
Details

Duct Size

Total B
(m)

1.8

System
Mass

Misc.
(Skid,
Duct)

270

Skid Size

75

Empty
Bed
Residenc
e Time
(EBRT)

Vessel
(m)

Standby fan with PLC upgrade. Stainless steel fans. High level systems opera2onal sensors. Con2nuous H2S monitoring. Stainless
Steel Drums. Epoxy Lined HDPE.

Length
D (m)

Optional Items

Width
C (m)

U2lises a specically designed ac2vated carbon for use in odour control systems where the primary cause of odour is as a result
of the presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to
meet any needs that fall outside the capaci2es of our standard ac2vated carbon materials.

(m)

Adsorptive Media

(sec)

FiltaCarbTM drum canister lter is designed to reduce logis2c and installa2on costs. The system is preloaded with media and is
factory tested prior to dispatch. The FiltaCarbTM lter is made from PVC and is constructed to be UV and corrosion resistant
(Op2onal; epoxy lined mild steel, stainless steel, or HDPE).

m3 /

Construction

FC75x1

Model

75
Series
FiltaCarb TM Package
Systems
FiltaCarb TM
Drum
Cartridges

Functional Description

The FiltaCarbTM drum canister lter is a cost eec2ve and ecient lter system that requires lille maintenance. The system is
designed for easy and simple lter changeover. The canisters are used in a range of congura2ons in skid mounted systems or
specialised designs. The system is a single-stage treatment using carbon adsorp2on technology. Hazardous gases are extracted
from the source using an extrac2on/blower fan that then vents the untreated gases through the lter media. The untreated gases
accumulate in the lower plenum of the lter before being evenly diused through the media of the lter bed where contaminates
are physically adsorbed. A specic ac2vated carbon media is used to treat the target gases to achieve more than 99% removal of
source gases.

17

Sustainable Modular
Filtration Systems
FiltaVentTM passive ven<ng series ground mount cartridge
odour ltra3on system for the control of odourous sewer
gases.

FiltaVentTM FV30 single cartridge

FiltaVentTM FV120 quad cartridge

FiltaVentTM FV60 dual cartridge

About FiltaVentTM carbon lter technology


FiltaVentTM passive vent lters are cost eec2ve and ecient ground
mounted lter systems with replaceable cartridges. Each one is a self-
breathable passive lter with low sta2c pressure that can be used to
solve a range of odour issues on sewage pumping sta2ons, vent stacks
and pressure relief valves. Depending on the ow capacity
requirements, there is a FiltaVentTM model congura2on that has
been designed to suit installa2on on top of air valves, sewer
manholes, pump sta2ons or small sewage treatment plants and also
to replace old corroded vent stacks.

Replacement FiltaVentTM cartridge lters:
All FiltaVentTM passive vent lters are supplied with replaceable
cartridges that can easily be changed by operators, when the carbon is
exhausted. At only 23 kg, the cartridge can be easily removed and
safely replaced manually. The media is a performance ac2vated
carbon for the combined removal of gases such as Hydrogen Sulphide
(H2S), Dimethyl Sulphide, Mercaptans and VOCs.

The FiltaVentTM range oers mul2-cartridge systems to meet larger
target ows. The units are robust and the independent plenum base
ensures air is evenly distributed throughout the media bed. This
op2mises the capacity of the ac2vated carbon lter media, therefore
maximising its performance.

Bioac2on FiltaVentTM lter systems are designed, engineered and
made locally to suit Australias wide and oten harsh range of
opera2onal condi2ons. FiltaVentTM lters have a high chemical and UV
resistance to provide signicant design life expecta2on and are
suitable for all clima2c condi2ons.

Benets of FiltaVentTM passive vent lters:

Suitable for municipal sewer and domes2c applica2ons


More than 99.5% of odours removed
Low sta2c pressure
Range of mul2-cartridge op2ons
Easy installa2on
Replaceable cartridges
Insect and vermin proof
Can connect to external vent duct
Vandal resistant

Plenum base of a FiltaVentTM


system showing the duct
connec2on op2ons, either
ducted ver2cally into the
wet well or via side duct.
FiltaVentTM FV30 system with cartridge loaded.

FiltaVentTM CART30 30 L/s cartridge

FiltaVentTM FV120 system with 4 x CART30 cartridges loaded.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

18

Sustainable Modular
Filtration Systems

Duct
Size

Static
Pressure
Vessel
(Pa)

Media
Depth

11

24

35

50

109

0.42

17

29

46

100

214

FV60

60

216

0.89 x 0.48

0.88

0.06

0.42

34

44

78

100

214

FV120

120

432

0.89 x 0.89

0.94

0.12

0.42

68

75

143

154

214

CART20

20

72

0.32

0.39

0.02

0.28

11

15

N/A

109

CART30

30

108

0.32

0.55

0.03

0.42

17

22

N/A

214

Model

Total
(kg)

0.28

0.03

Vessel
(kg)

0.02

0.88

GAC
Media
(kg)

0.64

(m)

0.5
0.5

( m3 )

Total (m)

1
1

(sec)

72
108

m3 / hr.

20
30

L/s

FV20
FV30

Series

(m)

(mm) ID

HDPE Construc2on, Inlet and outlet adaptor ange kit, Extrac2on fan Seat 15 0.37kW (Details on ow specica2ons available on
request)

System
Mass

Optional Items

Media
Volume

Adsorptive Media

A custom blend of Ac2carb EA1000 granular vapour ac2vated carbon and Ac2carb EA1000K pelle2sed impregnated ac2vated
carbon is used and specically designed for use in odour control systems where the primary cause of odour is as a result of the
presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to meet any
needs that fall outside the capaci2es of our standard ac2vated carbon materials.

System
Heights

FiltaVentTM passive ground mount lters are made from PVC and constructed to be UV and corrosion resistant (Op2onal HDPE). All
duct and pipe penetra2ons are PVC which have been constructed to be UV resistant. The lid has a gasket seal and is secured to the
vessel base and bolted securely ange to ange. More detailed specica2ons per model are available on request.

Vessel
Outside
Diameter

Construction

Empty
Bed
Residen
ce Time
(EBRT)

Capacity

FiltaVentTM FV120
quad cartridge system

Functional Description

FiltaVentTM passive ground mount lters are cost eec2ve and ecient lter systems with very low maintenance costs. The system is
designed for easy and simple lter changeover and replacement. The system is a single-stage treatment using carbon adsorp2on
technology. Hazardous gases are pushed through the lter media. The untreated gases accumulate in the lower plenum of the lter
before being evenly diused through the media of the lter bed where contaminates are physically adsorbed. A specic ac2vated
carbon media is used to treat the target gases to achieve more than 99.5% removal of source gases. FiltaVentTM lters are designed
to reduce logis2c and installa2on costs. The system comes with 1 - 4 canisters, depending on the model ordered, all are factory
tested prior to dispatch.

FiltaVentTM

FiltaVentTM
Replacement
Cartridges

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

19

Sustainable Modular
Filtration Systems
FiltaVentTM two-way passive series ground mount cartridge
odour ltra3on system for the control of odourous sewer
gases.

Exis3ng
Vent
Stack

About FiltaVentTM carbon lter technology

Benets of FiltaVentTM two-way passive vent lters:

FiltaVentTM two way passive vent lters are cost eec2ve and ecient
ground mounted lter systems with replaceable cartridges. Each one
is a self-breathable passive lter with low sta2c pressure that can be
used to solve a range of odour issues. Applica2ons for this system is
where there is a need to allow a high ow of inlet air on demand from
the system. The annulus lter design lowers the sta2c pressure across
the lter bed without compromising surface contact and residence
2me. The FiltaVentTM two way lter can act as or connect to a vent
stack to create air inow while trea2ng odorous oumlow.

Depending on the ow capacity requirements there is a range of


FiltaVentTM two way model congura2ons that has been designed to
suit installa2on on top of air valves, sewer manholes, pump sta2ons
and small sewerage treatment plants and also to replace old corroded
vent stacks.

Suitable for municipal sewer applica2ons


More than 99.5% of odours removed
Can connect to external vent duct / stack
Allows air inow into sewer system
Low sta2c pressure
Range of mul2-cartridge op2ons
Easy installa2on
Replaceable cartridges
Insect and vermin proof
Vandal resistant

Replacement FiltaVentTM cartridge lters:


All FiltaVentTM passive vent lters are supplied with replaceable
cartridges that can easily be changed by operators, when the carbon is
exhausted. At only 33 kg, the cartridge can be easily removed and
safely replaced manually. The media is a performance ac2vated
carbon for the combined removal of gases such as Hydrogen Sulphide
(H2S), Dimethyl Sulphide, Mercaptans and VOCs.
.

The FiltaVentTM range oers mul2-cartridge systems to meet larger


target ows. The units are robust and the independent plenum base
ensures air is evenly distributed throughout the media bed. This
op2mises the capacity of the ac2vated carbon lter media, therefore
maximising its performance.

The op2onal galvinised vent stack mount pictured above has been alached to the
FiltaVentTM system which has then been sealed at the top to enable the ltered air to
exhaust through the exis2ng vent stack which has been reposi2oned to the vent stack
mount.

Bioac2on FiltaVentTM lter systems are designed, engineered and


made locally to suit Australias wide and oten harsh range of
opera2onal condi2ons. FiltaVentTM lters have a high chemical and UV
resistance to provide signicant design life expecta2on and are
suitable for all clima2c condi2ons

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

FiltaVentTM 2WCART40 40 L/s cartridge

Two-way air ow
allows the lter to breath

20

Sustainable Modular
Filtration Systems

Duct Size

Static
Pressure

(m)

GAC
Media
(kg)

Vessel
(kg)

Total
(kg)

(mm)
ID

Vessel
(Pa)

144

0.5

1.14

0.06

0.10

33

24

57

50

40

FV80P

80

288

0.89 x 0.48

1.38

0.12

0.10

66

44

110

100

40

FV160P

160

576

0.89 x 0.89

1.44

0.24

0.10

132

75

207

154

40

2WCART40

40

144

0.32

0.92

0.06

0.10

33

N/A

33

N/A

40

Media
Depth

Capacity

System
Mass

( m3 )

40

Media
Volume

System
Heights

FV40P

Empty
Bed
Residenc
e Time
(EBRT)

Total
(m)

Inlet and outlet adaptor ange kit Vent stack mount


Extrac2on fan Seat 15 0.37kW (Details on ow specica2ons available on request)

Vessel
Outside
Diameter

Optional Items

(m)

A custom blend of Ac2carb EA1000 granular vapour ac2vated carbon and Ac2carb EA1000K pelle2sed impregnated ac2vated
carbon is used and specically designed for use in odour control systems where the primary cause of odour is as a result the
presence of mercaptans, Hydrogen Sulphide (H2S), and VOCs. Customised media blends and mixtures can be supplied to meet any
needs that fall outside the capaci2es of our standard ac2vated carbon materials.

(sec)

Adsorptive Media

m3 / hr.

FiltaVentTM
Replacement
Cartridges

FiltaVentTM two-way passive ground mount lters are made from PVC and constructed to be UV and corrosion resistant (Op2onal
HDPE). All duct and pipe penetra2ons are PVC which have been constructed to be UV resistant. The lid has a gasket seal and is
secured to the vessel base and bolted securely ange to ange. More detailed specica2ons per model are available on request.

L/s

FiltaVentTM

Construction

Model

2 Way
Series

FiltaVent FV160P
4 cartridge system

Functional Description

FiltaVentTM two-way passive ground mount lters are cost eec2ve and ecient lter systems with very low maintenance costs.
The system is designed for easy and simple lter changeover and replacement. The system is a single-stage treatment using
carbon adsorp2on technology. Hazardous gases are pushed through the lter media. The untreated gases accumulate in the lower
plenum of the lter before being evenly diused through the media of the lter bed where contaminates are physically adsorbed.
In addi2on to the treated air owing out through the lter, this system also enables unrestricted ow of air back through the
intake pipe to enable pressure reduc2on in the network. A specic ac2vated carbon media is used to treat the target gases to
achieve more than 99.5% removal of source gases. FiltaVentTM lters are designed to reduce logis2c and installa2on costs. The
system comes with 1 - 4 canisters, depending on the model ordered, all are factory tested prior to dispatch.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

21

Sustainable Modular
Filtration Systems
Bioac<ons services

Research and development commitment

Manufacture & Supply:


Bioac2on designs, engineers and manufactures all systems in Australia
to meet Australias strict engineering standards and stand up to
Australias harsh clima2c condi2ons. Bioac2on gives its clients the
exibility to choose from a range of precongured solu2ons that will
suit many general requirements. In addi2on Bioac2on is very happy to
deal with more challenging requirement sets and develop a custom
ltra2on system to resolve any issues. Bioac2on have modular system
designs available that are constructed on engineered skid bases to
enable easy transporta2on rapid installa2on and commissioning. All
Bioac2on ltra2on systems are made from more than 95% recyclable
materials including all the structural plas2cs and metals, as well as all
the natural or synthe2c lter media. The full range of Bioac2on
systems comes with a 10 YEAR Warranty from manufacturing and
materials defects, the lter media service life varies depending on the
media specied. Delivery can be arranged to any loca2on globally.

Installa2on, commissioning and training:


The modular plugnplay design of Bioac2ons systems means that
installa2on is quick and easy. With all Civil works completed
Bioac2ons installa2on team can install smaller systems like FiltaVentTM
ground mounted lters in as lille as 3hrs, While larger systems like a
FiltaBTFTM Biotrickling lter could take as lille as 1-3 days. Because
Bioac2ons lter range is user friendly, system commissioning and
training for the operators only takes a few hours at most and
Bioac2ons team is only a phone call away should ques2ons arise.

Bioac<ons Clients Include

The business has operated for over ten years with the rst ve years
spent in a research and development program prior to the forma2on
of Bioac2on Pty Ltd. The company con2nues a high level of research
and product development in conjunc2on with academic organisa2ons
and trade partners.

Bioac2on was originally established to design and construct deep-bed


bioltra2on systems using a unique organic lter media. The company
acquired BL Camtek Technologies, who produced ac2vated carbon
ltra2on systems, to expand its product base and incorporate their
technology into the Bioac2on range.

Bioac2on con2nues to develop industry leading technologies to


increase eciencies and levels of sustainability so our customers can
reduce costs and increase dependability. With advanced CAD systems
at our disposal we are able to run sophis2cated simula2ons to test our
designs and enable rapid development which can be used on
customised systems if required.

Maintenance & Service:


Bioac2ons lter range are designed for minimal maintenance and
easy servicing. Systems can be supplied with op2ons for sophis2cated
telemetry or simple media deple2on warning systems to suit the
requirements. The systems are designed to be vermin proof and
vandal resistant to minimise maintenance costs.
Air ow streamlines through a vessel in nega2ve pressure showing even
distribu2on of air through the media bed in the centre using
computa2onal uid dynamics.

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

24

Sustainable Modular
Filtration Systems

Company Details

Bioaction Pty Ltd

Head Office Reception PH: +61 2 4393 5503

Fax: +61 2 4394 0948

Sales:

Geoff Crook (Commercial Manager) PH: 0408 115 889

Scott Botham (Projects Manager) PH: 0404 977 155

Email: enquires@bioaction.com.au

Web: www.bioaction.com.au

Office / Factory Address:

Unit 9 / 18 Arizona Road, Charmhaven, NSW, 2259

Postal Address:

P.O. Box 4143, Lake Haven, NSW, 2263

Office Hours: 9am 5pm AEDT Mon-Fri

ABN: 17 136 514 817

ACN: 136 514 817

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

25

Sustainable Modular
Filtration Systems

Notes

2014-2015 Bioac3on Pty Ltd, All Rights Reserved.

28

Vous aimerez peut-être aussi