Académique Documents
Professionnel Documents
Culture Documents
PDA
taki
2009-06-01, 09:01 PM
Hi all,
I'm facing a big problem, I have a big number of SDC C H drop per cell in my area which decrease C SSR (nokia product).
Please advise
electron
2009-06-01, 09:08 PM
2009-06-01, 11:34 PM
2009-06-02, 12:01 AM
Hi all,
I'm facing a big problem, I have a big number of SDC C H drop per cell in my area which decrease C SSR (nokia product).
Please advise
Hi,
1. Kindly check the alarms whether there is alarms on TRX, C ombiner, etc
2. C heck Interference, (C o/Adj BC C H or other freq), change the ARFC N to the clean one.
3. Finally, you can move the SDC C H C hannel to the other Trx which is clean
br
taki
2009-06-02, 12:10 AM
Thanks friends for your suggestions but I tried all thinks mentionned without
success !!!!
:confused:
gprastomo
2009-06-02, 01:26 AM
Thanks friends for your suggestions but I tried all thinks mentionned without
success !!!!
:confused:
Tell me the specific problem, you give general data
taki
2009-06-02, 01:51 AM
2009-06-02, 02:02 AM
maybe it is N7 link problem,can you see some counter about A (BSC -MSC ) interface?
hassen
2009-06-02, 07:38 AM
Hi all,
I'm facing a big problem, I have a big number of SDC C H drop per cell in my area which decrease C SSR (nokia product).
Please advise
hi taki
i suspect transmission link ,and i advice you to ask for investigation A interface with
protocole analyzer,maybe there is hardware problem in bsc level matrix responsible to make connection through transmission link between bsc and bts devices during immediate assignmente.
have a look !
http://www.finetopix.com/showthread.php?t=1664
br hassen
taki
2009-06-02, 09:51 AM
hi taki
i suspect transmission link ,and i advice you to ask for investigation A interface with
protocole analyzer,maybe there is hardware problem in bsc level matrix responsible to make connection through transmission link between bsc and bts devices during immediate assignmente.
have a look !
http://www.finetopix.com/showthread.php?t=1664
br hassen
Hi Hassen thanks a lot for your help, take care
kahnoie
2009-06-13, 10:20 PM
Wrong t3212 timer value for few cells is lower than other cells would result in more periodic LU by MS results in high SDC C H load.
SDC C H drops are linked to interference from other cells or due to large cell coverage (many subscribers at the cell border, with low RXLEV). Steps that can be taken to reduce SDC C H blocking are:
1. Increase T3212 from every 4 hours to every 6 or 8 hours.
converted by W eb2PDFConvert.com
2009-06-18, 03:17 AM
Hi gprastomo,
I'm facing a SDC C H drop problem for about 200 cells !!!!
-I tried to change SD from trx to another one but no success
-The frequency plan is good
-No HW problem
So what's the problem
Please help
activate HO SD feature and chek for improvement.
Khairul
2009-06-18, 03:21 AM
2009-09-03, 02:33 AM
try to help:
1.
2.
3.
4.
5.
6.
ghassen
2009-09-03, 03:08 AM
Hi all,
I'm facing a big problem, I have a big number of SDC C H drop per cell in my area which decrease C SSR (nokia product).
Please advise
try to increase the C RH it can work
simmus0300
2009-09-03, 02:01 PM
try to help:
1.
2.
3.
4.
5.
6.
2009-09-03, 02:02 PM
Hi,
1. Kindly check the alarms whether there is alarms on TRX, C ombiner, etc
2. C heck Interference, (C o/Adj BC C H or other freq), change the ARFC N to the clean one.
3. Finally, you can move the SDC C H C hannel to the other Trx which is clean
br
Pl share the commands in nokia with parameters to checking above mentioned
suggestions.
diankestiwi
2009-09-03, 02:51 PM
i think maybe u can change sdcch kanal to the best kanal at that slot
ghassen
2009-09-03, 07:17 PM
Hi all,
I'm facing a big problem, I have a big number of SDC C H drop per cell in my area which decrease C SSR (nokia product).
Please advise
also you can check some counters
simmus0300
2009-09-04, 12:25 AM
2009-09-28, 03:05 AM
Hi Taki.
Try to check this:
1. timing advance of cell in urban areas, if you have exssesive propagation try to fix it by downtilt, many times the SDC C H drop is originated by some co-channel co-bsic that meet in long distance.
2. C heck the rxLevAccesMin and try to set it no more than -102 dB, sometimes we force the mobiles to get the cell in poor RF conditions, around -110. This a SDC C H DC by lost of radiolink during
signaling phase.
kais
2009-09-28, 04:15 AM
converted by W eb2PDFConvert.com
2009-09-28, 05:09 AM
2009-12-09, 03:41 PM
i think maybe u can change sdcch kanal to the best kanal at that slot
how do we know which one is the best kanal ?
diankestiwi
2010-01-05, 09:21 PM
2010-05-28, 01:25 AM
Please every body i want to know what mean this two sentence
"SDC C H lost radio connections (error indication) "
"SDC C H lost radio connections (connection failure)"
in Huawei system (BSC ) and I to resolve it.
it's the most important SDC C H drop reason in our network that affect seriously the C SSR
Thanks
capcipcup
2010-06-03, 04:31 PM
as i know we can use batrana for siemens ( and we can calculate from the statistic data ) so we compare each kanal where are better than other.
would you tell me which statistic data should i get
thanks
kadou26
2010-06-03, 07:18 PM
Ok Thank to all
mp9413
2010-06-05, 01:56 PM
Hi,
Abis trace would be useful. Observe the messages flow and identify the abnormal release in SDC C H should give you some hints.
mp
OptimiNSN
2010-06-06, 03:39 AM
Dear I recommend that you sent us the report ND204 of the BSC or BTS, who have problems, so we can help you.