Vous êtes sur la page 1sur 2

To order this part, call Lifco Hydraulics USA Toll Free at 1-800-952-7849

Sheet No.

STAINLESS STEEL- PRESSURE FILTER


Series

EH 60-90

1430 H

6000 PSI
1. Type index:

1.1. Complete filter: (ordering example)


EH. 90. 10VG. HR. E. P. VA.UG. 4. VA. -. AE
1

10

11 12

series:
EH
= stainless steel-pressure filter

nominal size: 60, 90

filter-material and filter-fineness:


80 G = 80 m, 40 G = 40 m,
25 G = 25 m stainless steel wire mesh
25 VG = 20 m(c), 16 VG = 15 m(c), 10 VG = 10 m(c),
6 VG = 7 m(c), 3 VG = 5 m(c) Interpor fleece (glass fiber)
resistance of pressure difference for filter element:
30
= p 435 PSI
HR
= p 2320 PSI (rupture strength p 3625 PSI)

filter element design:


E
= single-end open

sealing material:
P
= Nitrile (NBR)
V
= Viton (FPM)

filter element specification: (see catalog)


= standard
VA
= stainless steel
IS06 = see sheet-no. 31601

connection:
UG
= thread connection

connection size:
3
= -8 SAE
4
= -12 SAE

10

filter housing specification:


VA
= stainless steel

11

internal valve:
= without
S1
= with by-pass valve p 51 PSI
S2
= with by-pass valve p 102 PSI
R
= reversing valve, Q 18.50 GPM

12

clogging indicator or clogging sensor :


= without
AOR = visual, see sheet-no. 1606
AOC = visual, see sheet-no. 1606
AE
= visual-electrical, see sheet-no. 1615
VS1 = electronical, see sheet-no. 1617
VS2 = electronical, see sheet-no. 1618

1.2. Filter element: (ordering example)


01E. 90. 10VG. HR. E. P. VA
2. Dimensions:

type
EH 60
EH 90
connection
-8 SAE
-12 SAE
A
7.67
10.23
B
6.88
9.44
C
8.46
11.02
weight lbs.
18.70
20.95
volume tank
.08 Gal.
.10 Gal.
Connection assignments as shown in the table are standard. To exchange
connections see item 9 in type index.

series:
01E.
= filter element according to INTERNORMEN factory
specification

nominal size: 60, 90

- 7

see type index-complete filter

Changes of measures and design are subject to alteration!

EDV 01/05

900 Air Park Drive, Zanesville, Ohio 43701


phone
fax

740 - 452 - 7775


740 - 454 - 0075

e-mail
url

sales@atico-internormen.com
www.internormen.com

To order this part, call Lifco Hydraulics USA Toll Free at 1-800-952-7849

3. Spare parts:
item

qty.

1
2
3
4
5
6
7
8
9
10
11
12

1
1
1
1
1
1
1
1
1
1
1
1

designation

dimension
EH 60
01E.60

filer element
O-ring
O-ring
support ring
clogging indicator, visual
clogging indicator, visual-electrical
clogging sensor, electronical
clogging sensor, electronical
O-ring
O-ring
O-ring
screw plug

article-no.
EH 90
01E.90

22 x 3,5
56 x 3
63 x 2,6 x 1
AOR or AOC
AE
VS1
VS2
15 x 1,5
22 x 2
14 x 2
20913-4

304341 (NBR)
305072 (NBR)

304392 (FPM)
305322 (FPM)

312309
see sheet no. 1606
see sheet no. 1615
see sheet no. 1617
see sheet no. 1618
315357 (NBR)
315427 (FPM)
304708 (NBR)
304721 (FPM)
304342 (NBR)
304722 (FPM)
314442

item 12 execution only without clogging indicator or clogging sensor

4. Description:
The pressure filters of the series EH 90 are suitable for a working pressure up to 6000 PSI.
The pressure peaks are absorbed by a sufficient margin of safety. The EH-filter is in-line mounted.
The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is
bonded to the end caps with a high-quality adhesive. The flow direction is from outside to inside. Filter elements are available down
to a filter fineness of 4 m (c).
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a
high dirt-retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
INTERNORMEN-Filter elements are available up to a pressure difference resistance of p 2320 PSI and a rupture strength of p 3625 PSI.
The internal valves are integrated into the centering pivot for the filter element.
After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve
a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered.

5. Technical data:
temperature range:
operating medium:
max. operating pressure:
test pressure:
connection system:
housing material:
sealing material:
installation position:

+14F to +176F (for a short time +212F)


mineral oil, other media on request
6000 PSI
7917 PSI
thread connection
DIN 17440 - 1.4571 (316 Ti according to AISI)
Nitrile (NBR) or Viton (FPM), other materials on request
vertical

Classified under the Pressure Vessel Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).

6. Symbols:
without indicator

with electrical
indicator
AE 30 and AE 40

with visual-electrical
indicator
AE 50 and AE 60

with visualelectrical
indicator
AE 70 and AE 80

with visual
indicator
AOR/AOC

with electronical
clogging sensor
VS1

with electronical
clogging sensor
VS2

filter without
internal valve

filter with
by-pass valve

filter with
reversing valve

7. Pressure drop flow curves:

Precise flow rates see INF-Expert-System Filter, respectively p-curves; depending


on filter fineness and viscosity.

8. Test methods:

Filter elements are tested according to the following ISO standards:


ISO 2941
ISO 2942
ISO 2943
ISO 3723
ISO 3724
ISO 3968
ISO 16889

US 1430 H

Verification of collapse/burst resistance


Verification of fabrication integrity
Verification of material compatibility with fluids
Method for end load test
Verification of flow fatigue characteristics
Evaluation of pressure drop versus flow characteristics
Multi-pass method for evaluating filtration performance