Vous êtes sur la page 1sur 31

Fiber Optic Transmission System: Fiber-inthe-Loop

Block Diagram of the Network

Required Transmission System


Group 4
BTS Sites

E1/Bandwidth Requirement
3G
HSPA
WiMax

GSM 900

GSM 1800

Project 8
PLDT Munoz Reloc
Bago Bantay

2
2
2

3
3
3

5
5
5

20 Mbps
20 Mbps
20 Mbps

Project 6 (HUB)

Cattleya
Congressional Village

2
2

3
3

Total

12

18

Computation for HSPA


1E1
100
Mbps
x
=
2 Mbps

LTE

Broadband

40Mbps
40Mbps
40Mbps

100Mbps
100Mbps
100Mbps

30Mbps
40Mbps
40Mbps

20 Mbps

40Mbps

100Mbps

20Mbps

5
5

20 Mbps
20 Mbps

40Mbps
40Mbps

100Mbps
100Mbps

40Mbps
40Mbps

30

120Mbps

240Mbps

600Mbps

210Mbps

Fiber Optic Transmission System: Fiber-inthe-Loop


= 50E1

Computation for WiMax


=

200 Mbps x

1E1
2 Mbps

= 100E1
Computation for LTE
=

500 Mbps x

1E1
2 Mbps

= 250E1
Computation for Broadband
=

190 Mbps x

1E1
2 Mbps

= 95E1
Total E1 (HUB not included) = GSM 900 + GSM 1800 + 3G + HSPA + WiMax
+ LTE + Broadband
Total E1 = 10 + 15 + 25 + 50 + 100 + 250 + 95
= 545 E1
Therefore, STM 16 will be used because the required transmission
system exceeds that of STM 4

Power Budget
Transmit Power
Receiver
Sensitivity
FOC Loss
Connector Loss

-27dB
-58dB
0.35 dB/Km
1 dB/connector

Fiber Optic Transmission System: Fiber-inthe-Loop


Splice Loss
Fade Margin

Power
Power
Power
Power

Budget
Budget
Budget
Budget

=
=
=
=

0.3 dB/splice
3dB

Power Output - Receiver Threshold


3dBm - (-28dBm)
-27dB + 58dB
31 dB

Segment 1:
PLDT Munoz-Reloc to Project 8

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 1.0794 Km x 0.35dB/Km
FOC Loss = 0.378 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 3 splices
Splicing Loss = 0.9 dB

Fade Margin = 3 dB
Total Link Loss = 0.378 dB + 2 dB + 0.9 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 6.278 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 6.278 dB
Power Margin = 24.722 dB

Segment 2:
Project 8 to Sta. Rita Village/Congressional Village

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 1.0604 Km x 0.35dB/Km
FOC Loss = 0.371 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 3 splices
Splicing Loss = 0.9 dB

Fade Margin = 3 dB
Total Link Loss = 0.371 dB + 2 dB + 0.9 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 6.271 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 6.271 dB
Power Margin = 24.729 dB

Segment 3:
Sta. Rita/Congressional Village to Cattleya

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 1.0547 Km x 0.35dB/Km
FOC Loss = 0.369 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 3 splices
Splicing Loss = 0.9 dB

Fade Margin = 3 dB
Total Link Loss = 0.369 dB + 2 dB + 0.9 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 6.269 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 6.269 dB
Power Margin = 24.731 dB

Segment 4:
Cattleya to Project 6

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 0.7379 Km x 0.35dB/Km
FOC Loss = 0.258 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 2 splices
Splicing Loss = 0.6 dB

Fade Margin = 3 dB
Total Link Loss = 0.258 dB + 2 dB + 0.6 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 5.858 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 5.858 dB
Power Margin = 25.142 dB

Segment 5:
Project 6 to Bago Bantay

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 1.0041 Km x 0.35dB/Km
FOC Loss = 0.351 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 3 splices
Splicing Loss = 0.9 dB

Fade Margin = 3 dB
Total Link Loss = 0.351 dB + 2 dB + 0.9 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 6.251 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 6.251 dB
Power Margin = 24.749 dB

Segment 6:
Bago Bantay to PLDT Munoz-Reloc

FOC Loss = Total Distance x FOC Attenuation


FOC Loss = 1.5377 Km x 0.35dB/Km
FOC Loss = 0.538 dB

Connector Loss = Connector Loss x Number of Connectors


Connector Loss = 1dB/connector x 2 connectors
Connector Loss = 2 dB

Splicing Loss = Splicing Loss x Number of Splice


Splicing Loss = 0.3 dB/splice x 4 splices
Splicing Loss = 1.2 dB

Fade Margin = 3 dB
Total Link Loss = 0.538 dB + 2 dB + 1.2 dB + 3 dB

Fiber Optic Transmission System: Fiber-inthe-Loop


Total Link Loss = 6.738 dB

Power Margin = Power Budget Total Link Loss


Power Margin = 31 dB 6.738 dB
Power Margin = 24.262 dB

Outside Plant Design

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop

Fiber Optic Transmission System: Fiber-inthe-Loop


Segment 1: PLDT Munoz-Reloc to Project 8

Pole #

Distanc
e to
Next
Pole

A.1 (BTS
33.9m
1)

Owner

PLDT

A.2

45.5m

PLDT

A.3

66.3m

PLDT

A.4

42.5m

PLDT

A.5

48.2m

PLDT

A.6

32.7m

Meralc
o

Type of
Pole

Extensio
n Arm

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te

10 pin
alley
10 pin
alley

Side
Guy

Sidewal
k Guy

87.8m

PLDT

A.8

61.7m

PLDT

A.9

26.9m

Meralc
o

Concre
te
Concre
te

A.10

52.5m

Wood

A.11

23.6m

Meralc
o

A.12

20.9m

PLDT

A.13

46m

Meralc
o

Concre
te
Concre
te
Concre
te

A.14

44.4m

PLDT

Wood

A.15

37.2m

A.16

28.5m

A.17

33.4m

Meralc
o
Meralc
o
Meralc
o

Concre
te
Concre
te
Concre
te

Proposed
Compone
nt

Yes
Yes
Yes

Concrete
Pole,
Ground
Concrete
Pole

Concre
te

A.7

Groun
d

Yes
Yes
10 pin
alley
10 pin
alley

10 pin
alley
10 pin
alley
10 pin
alley

Ground

Yes

Fiber Optic Transmission System: Fiber-inthe-Loop


A.18

41.7m

PLDT

A.19

31.2m

Meralc
o

Concre
te
Concre
te

A.20

54.2m

PLDT

Wood

A.21

49.5m

PLDT

Wood

A.22

41.7m

A.23

32.3m

A.24

32.1m

A.25

32.5m

A.26

32.2m

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te

BTS 2

33.5m

Yes
10 pin
alley
10 pin
alley
10 pin
alley
Yes

Ground

Segment 2: Project 8 to Sta. Rita/Congressional Village

B.1

Distanc
e to
Owner
Next
Pole
36.1m
PLDT

B.2

39.6m

B.3

32.7m

B.4

32.2m

Meralc
o
Meralc
o
PLDT

B.5

32.6m

PLDT

Wood

B.6

35.5m

PLDT

Wood

B.7

38.8m

PLDT

Wood

Pole #

Type of
Pole

Extensi
on Arm

Concre
te
Concre
te
Concre
te
Wood

10 pin
alley

10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

Side
Guy

Sidewa
lk Guy

Proposed
Ground Compone
nt

Yes

Yes
Ground
Yes

Fiber Optic Transmission System: Fiber-inthe-Loop


B.8

50.9m

B.9

40.6m

B.10

38.9m

B.11

71m

B.12

46.4m

B.13

41.9m

B.14

22.2m

B.15

39.5m

B.16

25.4m

B.17

34.2m

B.18

37.1m

B.19

29.7m

B.20

47.4m

B.21

33.4m

B.22

31.1m

B.23

27m

B.24

31.7m

B.25

31.6m

B.26

32.7m

B.27

31.3m

Meralc
o
Meralc
o
Meralc
o
Meralc
o
PLDT
Meralc
o
Meralc
o
PLDT

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
PLDT

Wood

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te

Wood
Wood
Wood

10 pin
alley
10 pin
alley

Yes
Yes
Yes

10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

Concre
te
Wood

Concrete
Pole
Ground

Yes

Yes

Yes

Yes
Ground
10 pin
alley
10 pin
alley
10 pin
alley

10 pin
alley
10 pin
alley

Yes

Fiber Optic Transmission System: Fiber-inthe-Loop


B.28

35.4m

BTS 3

36.1m

Meralc
o

Concre
te

10 pin
alley

Yes

Segment 3: Sta. Rita/Congressional Village to Cattleya

C.10

Distanc
e to
Owner
Next
Pole
36.5m
Meralc
o
27.1m
Meralc
o
25.6m
Meralc
o
28.5m
Meralc
o
35.4m
Meralc
o
30.7m
Meralc
o
29.7m
Meralc
o
33.5m
Meralc
o
35.6m
Meralc
o
34m
PLDT

C.11

37m

PLDT

C.12

27.1m

PLDT

C.13

28.2m

PLDT

C.14

55.8m

PLDT

C.15

38.8m

Meralc

Pole
#
C.1
C.2
C.3
C.4
C.5
C.6
C.7
C.8
C.9

Type of
Pole
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret

Extensio
n Arm

10 pin
alley
10 pin
alley

Side
Guy

Yes

Sidewal
k Guy

Groun
d

Proposed
Compone
nt

Ground

10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

10 pin
alley
Ground
10 pin
alley
Yes
10 pin

Fiber Optic Transmission System: Fiber-inthe-Loop


o

e
Concret
e
Concret
e
Concret
e

C.16

37m

PLDT

C.17

36.6m

PLDT

C.18

31.5m

PLDT

C.19

50.3m

PLDT

C.20

52.7m

PLDT

C.21

32.3m

C.22

32.2m

C.23

44.9m

C.24

32.5m

C.25

46.6m

C.26

40.1m

C.27

39.5m

C.28

38.9m

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
PLDT

BTS 4

38.5m

Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Concret
e
Wood

alley

10 pin
alley, 44

44

Ground

10 pin
alley
26

Yes

10 pin
alley
10 pin
alley
10 pin
alley

Yes

10 pin
alley

Yes

Yes

Yes
Ground

Segment 4: Cattleya to Project 6


Distanc
e to
Pole #
Next
Pole
D.1

58.7m

Owner

Type of Extensio
Pole
n Arm

Meralc
o

Concre
te

10 pin
alley

Side
Guy

Sidewal
Ground
k Guy
Yes

Proposed
Compone
nt

Fiber Optic Transmission System: Fiber-inthe-Loop


D.2

29.3m

Meralc
o

D.3

41.5m

Piltel

D.4

38m

Piltel

D.5

44.9m

D.6

31.7m

D.7

43.1m

D.8

38.9

D.9

46.5m

D.10

49m

D.11

40.1m

D.12

43.3m

D.13

23.8m

D.14

48.8m

D.15
D.16
D.17

24.8m
24.2m
22.7m

D.18

26.4m

D.19

23.7m

BTS 5

48.9m

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Piltel
Meralc
o
Meralc
o
Meralc
o
Piltel
Meralc
o
PLDT
PLDT
PLDT
Meralc
o
Meralc
o

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood
Wood
Wood
Concre
te
Concre
te

10 pin
alley
Yes
Yes
10 pin
alley
10 pin
alley

Yes
Ground

10 pin
alley

Yes
10 pin
alley
10 pin
alley

44

Ground
Yes

10 pin
alley
10 pin
alley

Yes

Segment 5: Project 6 to Bago Bantay


Pole
#

Distanc
e to
Next

Owner

Type of
Pole

Extensi
on Arm

Side
Guy

Sidewa
lk Guy

Groun
d

Proposed
Compone
nt

Fiber Optic Transmission System: Fiber-inthe-Loop


E.1

Pole
22.7m

E.2

39.9m

Meralc
o
Piltel

E.3

43.3m

PLDT

E.4

49.2m

PLDT

E.5

34.7m

PLDT

E.6

55.8m

PLDT

E.7

32.7m

PLDT

E.8

36.3m

PLDT

E.9

47.7m

PLDT

E.10

39.8m

PLDT

E.11

33m

PLDT

E.12

39.2m

PLDT

E.13

32.9m

PLDT

E.14

32.6m

PLDT

E.15

22.2m

PLDT

E.16

47.6m

PLDT

E.17

25.1m

E.18

24.2m

E.19

25m

E.20

46.9m

Meralc
o
Meralc
o
Meralc
o
Meralc

Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood
Wood
Wood

10 pin
alley
Yes
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

Yes
Ground
Yes

Yes
Yes

Yes
Ground

Yes
10 pin
alley
10 pin
alley

Yes

Yes
10 pin
alley
10 pin

Yes

Fiber Optic Transmission System: Fiber-inthe-Loop


E.21

37m

E.22

32.3m

E.23

22.5m

E.24

30.3m

E.25

39.1m

E.26

30.2m

E.27

33m

BTS

33.6m

o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
PLDT
Meralc
o
Meralc
o

Wood
Wood
Concre
te
Concre
te
Concre
te
Wood
Wood

alley
10 pin
alley
10 pin
alley
10 pin
alley

Ground

Yes

10 pin
alley
10 pin
alley

Yes

Yes

Segment 6: Bago Bantay to PLDT Munoz-Reloc

F.1

Distan
ce to
Next
Pole
27.6m

F.2

42.4m

F.3

31.4m

F.4

31.7m

F.5

26.7m

F.6

52m

F.7

48.7m

F.8

48.4m

Meralc
o
PLDT

F.9

39m

PLDT

Pole #

Owner
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
PLDT

Type of
Pole

Extensi
on Arm

Concre
te
Concre
te
Concre
te
Wood

10 pin
alley

Concre
te
Concre
te
Concre
te
Concre
te
Concre

Side
Guy

Sidewa
lk Guy

Groun
d

Proposed
Compone
nt

Ground
Yes
10 pin
alley
10 pin
alley
10 pin
alley

Yes

Yes
Yes

Fiber Optic Transmission System: Fiber-inthe-Loop


F.10

42.4m

PLDT

F.11

30.6m

PLDT

F.12

39.7m

F.13

41.6m

F.14

39.4m

F.15

38.9m

F.16

44.5m

F.17

54m

F.18

23.2m

F.19

34.2m

F.20

39.8m

F.21

40.3m

F.22

56.2m

F.23

26.9m

F.24

35.1m

F.25

48.9m

F.26

23.1m

F.27

49.3m

F.28

39.5m

F.29

27.9m

Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc

te
Wood
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood
Concre
te
Concre
te
Concre
te
Wood
Concre

10 pin
alley

Yes
Yes

10 pin
alley

Ground

10 pin
alley
10 pin
alley

Yes
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley

10 pin
alley

Ground
Yes

Yes
Yes

Yes
Ground

10 pin

Fiber Optic Transmission System: Fiber-inthe-Loop


F.30

28.6m

F.31

31.3m

F.32

59.9m

F.33

51.3m

F.34

37.9m

F.35

36.6m

F.36

30.4m

F.37

29.3m

F.38

36.7m

F.39

38.7m

o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o
Meralc
o

te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Concre
te
Wood

alley
10 pin
alley
Yes
10 pin
alley
10 pin
alley
10 pin
alley
10 pin
alley
Ground
10 pin
alley
10 pin
alley
10 pin
alley

Yes

BTS 1

Bill of Materials
Item

Description

Picture

Qty

Unit

Fiber Optic Transmission System: Fiber-inthe-Loop

Ericsson
Concentric
Core Loose
Tube 24
144 Fibers
TOL 403
2008 ADSS
GRHSLLDV
dielectric
(Single Mode,
non-metallic)
Fiber Access
Terminal,
NCD 518
1200
48
connections
(Optical
Distribution
Frame)
Patch Cord,
High Grade
Angled
Polished
Connectors,
TSR 392
(Ericsson)
ZXMP S385
SDH-Based
Multi-Service
Node
equipment
(SDH
Equipment,
STM-16
capable)

6480

meter

sets

36

sets

sets

Fiber Optic Transmission System: Fiber-inthe-Loop


5

Proposed
Materials

Ground

20

sets

Concrete Pole

pcs

Fiber Optic Transmission System: Fiber-inthe-Loop

Attachments
Brochures
ZXMP S385 SDH-Based Multi-Service Node equipment
Upswing of services poses a gigantic challenge for network bandwidth. On request
by transport network evolution, multi-service transport equipments featuring large
capacity, flexible dispatch, high reliability, elastic bandwidth and upgradeability are
needed to handle service delivery in the core
network.
Considering service diversity and variation of
network architecture, inheriting ZTEs technology
patents and experience in the field of SDH and
implanting new technological contents in SDH
equipments,

ZTE

launches

ZXMP

S385,

an

intelligent STM-16/STM-64 multi-service transport


platform designed advanced technology, allowing
customers to build the efficient and competitive
network.
Highlights
Targeting

network

backbone

layer

or

large-

capacity convergence layer applications, ZXMP


S385 can be served as medium-capacity DXC, large-capacity ADM, while enabling
Ethernet switch and ATM switch functionalities via MSTP functions. It can be flexibly
configured as REG/TM/ADM/MADM when serving as ADM. It has the ability to
smoothly upgrade from STM-16 to STM-64.

Large-capacity and flexible service dispatch capability


The equipment has the ability to process multiple lines of ECCs, fully satisfying the
requirements for complex networking, supporting complex network topologies, such

Fiber Optic Transmission System: Fiber-inthe-Loop


as linear, ring, hinge, ring with chain, tangent ring and crossing ring, at levels of
STM-1/STM-4/STM-16/STM-64.

Strong multi-service access ability


ZXMPS 385 offers versatile service interfaces: STM-64/STM-16/STM-4/STM-1 optical
interfaces; STM-1, E3/T3, E1/T1 (support framing processing) electrical interfaces;
POS interface, ATM interface, FE/GE Ethernet interfaces and SAN interface. Multiple
bearer modes like EOS, embedded RPR and embedded MPLS are available to deliver
Ethernet private line (EPL), Ethernet virtual private line (EVPL), Ethernet private LAN
(EPLAN)

and

Ethernet

virtual

private

LAN

(EVPLAN)

services,

addressing

requirements for multiple technologies in different networking environments.

Highly reliable and complete equipment protection


ZXMP S385 provides perfect equipment-level protection: with redundant design in
hardware, dual-bus architecture is adopted in service bus, overhead bus and clock
bus, resulting in a vastly improved system reliability and stability. Two cross-connect
clock boards are employed to perform 1+1 protection for cross-connect clock.
1:N hardware service protection for PDH service board: 1:N (N<=9) protection for
E1/T1 service board, 1:N (N4) protection for E3/T3, STM-1 and FE electrical
interfaces.
Multiple protection modes include cabinet external power supply protection, board
power supply protection and sub-rack power access protection.

Perfect and intelligent network protection


ZXMP S385 supports perfect network-level protection: enabling ITU-T-recommended
networking characteristics, protection modes containing: 1+1 link multiplex section
protection, link 1:N protection (N=14), unidirectional path protection ring, 2-fiber
bidirectional multiplex section protection ring, 4-fiber bidirectional multiplex section
protection ring, dual node interconnection protection (DNI), subnetwork connection
protection (SNCP), and logic subnetwork protection (LSNP).
ZXMP S385 features robust intelligence, supports automatic discovery of network
topology and resource, automatic and rapid end-to-end service provision and
resistance to multi-node failure in the network; its also supports multi-priority
service protection and restoration policy.

Outstanding scalability

Fiber Optic Transmission System: Fiber-inthe-Loop


ZXMP S385 can be smoothly upgrade to 10G system from 2.5G system. It can
perform dispatch and add/drop of vast lower-order services during dispatching highspeed services. Designed with cutting-edge GFP, LCAS technologies, the system
supports data/voice-oriented hybrid transmission, ensuring steady extending
capabilities to dispatch and process data services.

Sound design, easing operation and maintenance


ZXMP S385 supports mixed insertion of boards, easing service configuration and
network planning & optimization. System operation adopts front-facing interfaces,
easier for maintenance.
ZXMP S385 employs pluggable optical modules (SFP module, LC connector) and
supports ALS functions; various optical boards and boards share spare parts, driving
down cost. It supports online optical power detection for all optical interfaces,
facilitating rapid location of line failure and boosting maintenance efficiency.
Highly integrated equipment results in lowered expenditure for space; low power
consumption reduces electricity expense.

Vous aimerez peut-être aussi