Académique Documents
Professionnel Documents
Culture Documents
Spring
Ultimate Measurement
Instruments
General Catalog
HVAC Testing
Indoor Air Quality
Industrial Hygiene
Cleanroom Contamination Control
Industrial Flow Testing
Aerosol Research
Fluid Mechanics Research
Anemometers / Indoor Air Quality Monitors / Gas Monitors / Dust Monitors / Sound Meters / Vibration Meters / Particle Counters
Cleanroom Monitoring System / Aerosol Research Instruments / Mass Spectrometer / Automotive Testing Instruments / Fluid Mechanics Research Instruments
www.kanomax-usa.com
Kanomax Group
Since our inception 60 years ago, Kanomax has been the most promising manufacturer of a broad range of precision
measuring instruments for fluid mechanics research, environmental, aerosol research, particle measurement, and
customized system applications. As a company that prides itself in technology, product quality, and service, we have
been enjoying an unsurpassed reputation in the industrial and academic fields.
Global Network
Our direct subsidiaries and Kanomaxs affiliates and well-trained distributors worldwide are there to provide the most
efficient support and service for you. Our global network is always listening to the voice of customers, like you, in order to
keep providing the best measurement solutions possible.
Kanomax Holdings Inc. (New York, NY)
ISO Certification
Kanomax is an ISO 9001/ISO14001 certified company. Kanomax management and
production procedures adhere to these international quality standards.
Aerosol/Particle Measurements
Cleanroom Contamination Control
Aerosol Research
Fluid Measurements
Fluid Mechanics
Particle Generator
Featured Products
Handheld Anemometer
Capture Hood
Aerosol Monitor
Applications
Handheld
Anemometers
Specifications
Model
Sensor Type
Air Velocity Ranges
ft./min
m/s
Resolution
Accuracy
Air Flow
CFM (ft3/min)
Temperature Ranges
Accuracy
Relative Humidity Ranges
Accuracy
Differential Pressure Ranges
Accuracy
Dimensions
Main Unit
Probe
Weight
3
AnemomasterTM
AnemomasterTM
ClimomasterTM Series
Multi-function hot-wire
Anemometer with detachable
compatible probes
Simultaneous display of
temperature and airflow or air
velocity
AnemomasterTM Lite
LITE
Climomaster Series
6810 Series
Hot-wire
Hot-wire
Hot-wire
Rotating Vane
2 to 3940
2 to 6000
2 to 9480
40 to 7800
0.01 to 20.0
0.01 to 30.0
0.01 to 50.0
0.2 to 40
0.01 m/s
0.01 m/s
0.01 m/s
0.01 m/s
+/- 1% of reading
n/a
0 to 2,709,360
0 to 2,709,360
0 to 9,999
+/- 1F (0.5C)
+/- 1F (0.5C)
+/- 1F (0.5C)
n/a
n/a
0.2 to 98.0% RH
0.5 to 95.0% RH
n/a
n/a
+/- 2% of reading
+/- 2% of reading
n/a
n/a
n/a
n/a
1.0 to 10 mm in diameter
Includes probe,
Temperature Ranges
Accuracy
+/- 2.0%RH
Accuracy
Interface
Datalogging
Up to 20,000 records
0 to 1 V
Power Supply
6 x AA Batteries or AC Adapter
Dimensions
Weight
Probe Specifications
Model
6531-2G
6541-2G
6561-2G
6542-2G
6533-2G
6543-2G
6551-2G
6552-2G
Probe Type
Uni-Directional
Uni-Directional
Uni-Directional
Omni-Directional
Omni-Directional
Omni-Directional
Mini-Spherical
Mini-Spherical
Air Velocity
2 to 6000 fpm
2 to 6000 fpm
2 to 9840 fpm
2 to 6000 fpm
2 to 1000 fpm
2 to 1000 fpm
2 to 6000 fpm
2 to 6000 fpm
Temperature
-4 to 158F
-4 to 158F
-4 to 158F
-4 to 158F
-4 to 158F
-4 to 158F
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Relative Humidity
Accessories
6501-AE
6501-BE
6531-04:
6531-05:
6531-06:
6000-41:
6000-31:
6000-61:
6113-02:
DPU-S245:
TP-202L:
6531-04
6531-05
6000-61
Includes
Applications:
Articulating Tip
HVAC Testing
(Professional only)
Facility Maintenace
Critical Environment Certification
IAQ Investigation
Specifications
Model
Probe Type
Telescopic
Temperature Ranges
Accuracy
Accuracy
Interface - Digital
Analog (Option)
Datalogging
Power Supply
None
6 x AA batteris or AC Adapter
Dimensions
Weight
Accessories
6036-AE:
6036-BE:
6035-AE:
6035-BE:
6000-31:
6000-61:
DPU-S245:
TP-202L:
The air velocity sensor is heated and temperature elevated (relative to the surrounding
air) by means of control electronics. The temperature compensation sensor senses the
ambient, or surrounding air temperature, and forces the velocity sensor to stay at a
constant overheat above the ambient. The circuit forces the voltage to be equal by means
of an operational amplifier. Air flowing past
Air velocity sensor
the sensor tends to cool the sensor, thus
driving down its resistance. The amplifier
responds by immediately delivering more
power to the circuit to maintain voltage
equilibrium. Delivered power is converted
into electrical signals to display.
Temperature compensation sensor
Anemomaster TMLITE
Specifications
Model
6006
Temperature Ranges
Accuracy
Power Supply
Dimensions
Accessories
4 x AA Batteries or AC Adapter
Weight
with probe with 79 in (200 cm) cable, extension rod, shoulder strap, and 6
pcs. C cell batteries, and NIST Certificate
Specifications
Model
Air Velocity Ranges
Accuracy
Temperature Ranges
Accuracy
Differential Pressure Ranges
Accuracy
Interface
Datalogging
Analog Output
Built-in Printer
Power Supply
Dimensions
Weight
6113
6114
20 to 9840 fpm (0.10 to 50.0 m/s)
+/- 3% of reading +0.1 m/s
32 to 212F (0 to 100C)
+/- 2.0F (1.0C)
+/- 5.00 kPa *Option
+/- 3% of reading +0.01 kPa
RS232C
100 measurements
0 to 1 V *Option
6 x C cell Batteries
W7.9 x H5.9 x D3.9
2.2 lbs (1 kg)
Accessories
6113-01:
6113-02:
6113-03:
6113-04:
6113-07:
6113-08:
Spare Probe
AC Adapter
Extension Rod
Shoulder Strap
Pressure Sensor
Analog Output
Specifications
Model
6812
6813
2.75 Head
1.00 Head
2.75 Head
1.00 Head
2.75 Head
1.00 Head
ft/min
40 to 7800
300 to 6800
40 to 7800
300 to 6800
40 to 7800
300 to 6800
m/s
0.20 to 40.0
1.5 to 35.0
0.20 to 40.0
1.5 to 35.0
0.20 to 40.0
1.5 to 35.0
Resolution
0 to 9999
n/a
n/a
n/a
Accuracy
n/a
n/a
n/a
5.0 to 95.0% RH
Accuracy
n/a
n/a
+/- 2.0% RH
3 x AA Batteries
3 x AA Batteries
3 x AA Batteries
Power Supply
Main Unit Dimensions
Weight
AP275
n/a
n/a
n/a
APT275
2.75 Head
40 to 7800
0.20 to 40.0
+/- (1.0% reading + 1 digit)
-4 to 212
-20 to 100
+/- (0.3C +0.2% of reading in C)
AP100
APT100
1.00 Head
300 to 6890
1.5 to 35.0
+/- 0.50% FS + 0.75% reading + 1 digit
n/a
n/a
n/a
-4 to 212
-20 to 100
+/- (0.3C +0.2% of reading in C)
Model
Relative Humidity
Range
Resolution
Accuracy
Temperature
F
C
Accuracy
HTP202
5.0 to 95.0% RH
0.1% RH
+/- 2.0% RH
-4 to 176
-20 to 80
+/- (0.3C +0.2% of reading in C)
Three separate power supplies 110 VAC 50/60 Hz, 220 VAC 50/60 Hz, and 10-30 VDC
Three concurrent outputs for each measurement: 0-1 VDC, 0-5 VDC, and 4-20 mA DC
Temperature Range -4 to 212F (-20 to 100C)
The new Kanomax TABmasterTM is the perfect tool for accurate supply and return
airflow measurements. Interchangeable hoods make it easy to sample the air for
any duct size. The unit is lightweight and easy to handle. The full color screen can
be tilted so its always at the optimal viewing angle regardless of height.
Features:
23 to 2500 cfm (40 to 4250 m3/h) range
Simultaneously measures and displays air flow, temperature and humidity
Displays the direction of the airflow
Store up to 8,000 measurements
Advanced storage feature allows you to store multiple measurements under a single ID#
Built-in back pressure compensation ensures accuracy for large volumetric flow
measurements
Applications:
HVAC testing, adjusting and balancing
Air volumetric flow measurements through registers, diffusers and grilles
Direct readout at supply and return airflow
Air velocity measurement in the duct
Check filter fouling by measuring differential pressure
Specifications
6710
Model
Airflow Range
6715
23 to 2500 CFM (40 to 4250 m3/h)
Accuracy
Resolution
Air Velocity Range
Accuracy
Resolution
1m3/h
n/a
n/a
3%0.05m/s of readings
n/a
Temperature Range
32 to 122F (0 to 50C)
Accuracy
Resolution
0.1C
Humidity Range
0 to 100% RH
Accuracy
+/- 3.0% RH
Resolution
0.1% RH
Interface
USB
Datalogging
Up to 3000 measurements
Power Supply
Hood Dimensions
Up to 8000 measurements
AA batteries or AC adapter
2x2 ft (610x610 mm), 1x4 ft (305x1220 mm), 2x4 ft (610 x 1220 mm)
3x2 ft (915 x 610 mm), 3x3 ft (915x915 mm), 500x500mm
Weight
Accessories
710-01:
6
6710-02:
6710-03:
6710-04:
710-05:
6
6710-06:
6710-07:
6710-08:
Micromanometer DP500
Smart micrometer for TAB professionals
Pressure Measurement
Specifications
Model
DP500
0.15 to 40 m/s (with Pitot tube)
0.15 to 15 m/s (with Velocity Matrix)
3%0.05m/s of readings
Accuracy
Pressure Ranges
-2500 to 2500 Pa
Temperature Ranges
0 to 50C
Accuracy
0 to 100%RH
Accuracy
3%RH(10~90%RH)
Interface
Datalogging
8000 measurements
Power Supply
4 x AA Batteries or AC Adapter
Features:
Totally
sensing
Specifications
Easy Fit Ellipsoidal Pitot Tube
Overall Length (m)
0.2
0.3
0.3
0.5
0.5
2.3
Gland (inch)
1/4
3/8
0.75 0.75
1.0
1.0
3/8
0.3
1.0
1.25 1.25
1.83
2.13
2.44
2.74
1.0
1.22
1.52
1.83
9.5
9.5
12.7
19
19
19
9.5
9.5
12.7
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
1/2
Gland (inch)
3/8
1/2
1/2
1/2
3/8
0.7
1.2
2.2
3.2
10
Flow Grids
For Accurate In-Duct Volume Flow Measurements
Airflow Measurement
Kanomax flow grids produce averaged total and sub-static pressures signals to generate
an enhanced velocity pressure signal, outside the duct wall, that directly relates to the
volume flow, providing accurate and reliable outputs where other flow measuring
devices are found to be unsatisfactory. Works directly with Micro-manometers, pressure
transducers, Magnahelic gauges, and pressure activated alarm switches. These are ideal
for ventilation monitoring for LEEDS and many other facility management monitoring
applications.
Features:
Sizes from 4.0 (100mm) diameter to 10 ft.(3.0 meters) square
Uncertainty of flow measurement is within +/- 1.0%
High temperature systems up to 850C are available
Stainless steel grade 321 tube supplied as standard, other grades of steel or alloys
Standard Sizes
Rectangular Grids
Radial Grids
Type A
6.4mm (1/4)
diameter tube
100 to 450
150 to 450
Type B
12.7mm (1/2)
diameter tube
250 to 650
350 to 1200
Type C
25.4mm (1)
diameter tube
750 to 1000
800 to 2000
Type A
6.4mm (1/4)
diameter tube
Diameter (mm)
100 to 500
Type B
12.7mm (1/2)
diameter tube
Diameter (mm)
500 to 1100
Type C
25.4mm (1)
diameter tube
Diameter (mm)
1100 to 2500
X Flow Grids
For Accurate In-Duct Volume Flow Measurements
X flowgrids will give useful and reliable readings in a wide variety of in-duct locations
often where other flow rate measuring devices are found to be unsatisfactory or difficult
to install. The low cost design consists of two tubes mounted diagonally through the
cross section of the duct. They generate an averaged signal for both the total and substatic (X) or static (UX) pressure along the length of each tube to generate a differential
pressure signal that directly relates to volume flow.
Features:
Economical method of measuring volume flow within a duct
Uncertainty of volume or mass flow measurement within +/- 5.0%
Stainless steel grade 321 tube supplied as standard
Model
Air Velocity Ranges
MX8
UX8
Maximum Temperature
Diameter of Tubes
Weight
MX16
UX16
Accuracy
11
Specifications
+/- 5%
176F (80C)
5/16 (8mm)
5/8 (16mm)
28.1 (715mm)
26.7 (680mm)
60.4 (1534mm)
59.4 (1510mm)
1 lbs (454 g)
3 lbs (1361 g)
Includes
The
The
6162
Interface
RS232C
Datalogging
999 measurements
Analog Output
Remote Terminal
Probe Specifications
Model
0203
0204/0205
Temp. Range
Air Velocity
Measuring Range
32 to 212F
212 to 392F
n/a
572 to 752F
n/a
Accuracy
Accuracy
Dimensions / Weight
Dimensions
Weight
392 to 572F
Power Supply
0 to 1 V
START/STOP Key
32 to 932F (0 to 500C)
+/- 1% of reading
Probe Cables
0204
0205
Teflon Coating
Heat-resistance
392F (200C)
Extension Cable
Vinyl Coating
Heat-resistance
176F (80C)
Accessories
0203:
0204:
0205:
6162-03:
6162-04:
6162-05:
6162-06:
6162-07:
6000-41:
6511-09:
DPU-S245:
TP-202L:
Probe Dimensions
*Length in mm
MODEL 0203
MODEL 0204
Entire Length
Entire Length
Probe Cable
MODEL 0205
12
Multi-Channel Anemometers
Multi-Channel
Measuring
Instruments
Interface
Analog Output
Power Supply
Dimensions
Weight
13
Multi-Channel Anemometers
Airflow Transducer
Model 6332 / 6332D
4-Channel AnemomasterTM
Model 1570
Multi-Channel AnemomasterTM
Model 1550 / 1560
6332/6332D
1570
1550 / 1560
V Probe
V Probe
n/a
n/a
32 to 212F (0 to 100C)
n/a
n/a
5.0 to 95.0% RH
n/a
n/a
RS232C
DC 4 to 20mA or DC 0 to 5V
0 to 5 V
0 to 5 V
DC or AC
AC
AC
Multi-Channel Anemometers
Smart
6332
6332D
Power Consumption
Approx. 2.0 W
Power Supply
Dimensions
Weight
DC 12 to 24V or AC 80 to 240V
W3.1 x H5.0 x D1.2
0.7 lbs (320 g)
6332D
6332
channel display
Model 1570 includes data processing software, RS232C cable, power cable,
and 2 pc. fuse
1570
Varies by probe, See below for Probe Specifications
0.01 m/s
RS232C
0 to 5V
AC 85 to 265V
W10.2 x H2.8 x D7.9
5.7 lbs (2.6 kg)
Compatible Probes
Air Velocity Proves (V Probes)
Probe Specifications
Model
Probe Type
Air Velocity
0962-00
Uni-Directional
20 to 9840 fpm (0.10 to 50.0 m/s)
0963-00
Uni-Directional
20 to 9840 fpm (0.10 to 50.0 m/s)
0965-00/-01
Omni-Directional
20 to 4920 fpm (0.10 to 25.0 m/s)
Miniature Probe
with built-in temperature compensation
0965-09/10
Omni-Directional
20 to 9840 fpm (0.10 to 50.0 m/s)
Miniature Probe
with independent temperature compensation
Probe Specifications
Model
Probe Type
Air Velocity
15
0965-07
Omni-Directional
20 to 4920 fpm (0.10 to 25.0 m/s)
0965-08
Omni-Directional
20 to 4920 fpm (0.10 to 25.0 m/s)
The
1560
Model
1550
1560
Resolution
0.01 m/s
Temperature Ranges
Resolution
Accessories
1500-01:
1500-02:
1500-03:
1504-04:
1511-01:
1512-01:
S620-00:
Multi-Channel Anemometers
Features:
0.1C
Resolution
0.1% RH
RS232C for PC Connection
RS232C for Cascade *Option
Interface
Analog Output
Power Supply
AC Adapter
Dimensions
11 lbs (5 kg)
Weight
Probe Specifications
Model
Probe Type
Air Velocity
Temperature Ranges
Relative Humidity Ranges
0962-21
0963-21
0965-21
0963-31
0965-31
Uni-Directional
Uni-Directional
Omni-Directional
Uni-Directional
Omni-Directional
32 to 212F (0 to 100C)
n/a
32 to 212F (0 to 100C)
n/a
32 to 212F (0 to 100C)
n/a
32 to 212F (0 to 100C)
5.0 to 95.0% RH
32 to 212F (0 to 100C)
5.0 to 95.0% RH
Modules
Specifications
Model
Module Type
# of Channels
1504 V Module
1511 VT Module
Air Velocity
Analog Output
16
Applications
Ventilation Testing
Thermal Comfort Control
Occupational Health Control
Monitoring Toxic Gas
17
Features:
Simultaneous measurements of CO, CO2, Temperature, and Relative humidity
Calculates Dew point, Wet bulb temperature, Absolute humidity, Humidity Ratio, and
% Outside Air
interface with RS232C or USB and software for real-time measurements and
downloading data to your PC
Complete with probe with 79 in (2m) cable, probe stand, calibration cap & connection
tube, data processing software, RS232C cable, USB to serial adapter, 6 pcs. AA
batteries, carrying case, and NIST-Traceable calibration certificate
Specifications
Model
2211
0 to 500 ppm
+/- 3% of reading
0 to 5000 ppm
+/- 3% of reading
-4 to 140 F (-20 to 60 C)
+/- 1.0F (0.5C)
2.0 to 98.0 %RH
+/- 2% of reading
1500 measurements
Analog Output
0 to 1 V *Option
Power Supply
6 x AA Batteries or AC Adapter
Dimensions
Weight
Software Included
RS232C
Accessories
6113-02:
2211-09:
DPU-S245:
6000-03:
TP-202L:
AC Adapter
Analog Output
Portable Thermal Printer
Printer Cable for DPU-S245
Rolled Printer Paper (10 rolls)
Indoor Comfort
Comfort is very subjective and will vary from one individual to the next, but
ASHRAE Standard 55 provides guidelines for a comfort zone that most people
will feel comfortable in. This comfort zone is derived from both temperature
and humidity and varies depending on the season. See the chart to the right
for details. The 2211 IAQ Monitor from Kanomax can measure both parameters
simultaneously indicating if changes are needed to make a buildings occupants
comfortable.
The monitor can also check CO2 levels and determine the rate of exchange, or the
percentage of outside air, being introduced to a building per ASHRAE Standard
62. Controlling the rate of exchange with the HVAC system is critical to ensuring
occupant well-being. Too much CO2 build-up can cause lethargy and make it
difficult for individuals to concentrate. Too much outside air may also be harmful
if its introducing external pollutants to the environment.
The 2211 is a great tool for IAQ investigation and spot checks to ensure an indoor
environment remains within desired levels to maintain occupant health and
comfort. The ability to measure all of these parameters in a single instrument
simplifies the labor involved and eliminates the need to purchase and learn
multiple instruments.
18
humidity
Gas Monitors
The S500 has data logging function and USB interface for PC
communication
Specifications
Model
Measurement Units
T/H* Sensor
On-board alarm
Remote Sensor
Datalogging
Interface
Analog Output
Power supply
Dimensions
Weight
S200
S300
S500
ppm or mg/m3
ppm or mg/m3
ppm or mg/m3
Option *
Option *
Option *
4,300 measurements
RS232C
0 to 5 V
0 to 5 V
Features:
Range (ppm)
Accuracy
Resolution
Ammonia
0 - 100
+/- 5 ppm
0.1 ppm
Ammonia (leak)
0 - 1000
+/- 15%
1 ppm
Carbon monoxide
0 - 100
+/- 5 ppm
0.1 ppm
Carbon monoxide
0 - 1000
+/- 10%
1 ppm
Carbon dioxide
0 - 2000
+/- 40 ppm + 3%
10 ppm
Carbon dioxide
0 - 5000
10 ppm
Hydrogen
0 - 5000
+/- 10 %
1 ppm
0 - 10
0.01 ppm
Hydrogen sulphide
Methane
0 - 9999
+/- 15 %
1 ppm
Ozone
0 - 0.150
0.001 ppm
Ozone
0 - 0.5
0.001 ppm
Nitrogen dioxide
0 - 1.0
0.001 ppm
NMHC 3,4
0 - 25
+/- 10 %
0.1 ppm
Perchloroethylene
0 - 200
+/- 5 ppm
1 ppm
0 -10
0.01 ppm
Formaldehyde
0 -10
0.01 ppm
VOC
0 - 25
+/- 10 %
0.1 ppm
VOC
0 - 500
+/- 10 %
1 ppm
VOC PID
0 - 20
+/- 10 %
0.01 ppm
VOC PID
0 - 1000
+/- 10 %
0.1 ppm
Sulphur dioxide
Sensor
Range (ppm)
Accuracy
Resolution
MS1
CO2
CO
0 - 2000
0 - 100
1 ppm
0.1 ppm
MS2
CO2
CO
VOC (PID)
0 - 2000
0 - 100
0 - 25
1 ppm
0.1 ppm
0.01 ppm
19
application
Accessories
R01:
R10:
R13:
R31:
R32:
R33:
R40:
R52:
Features:
The
Networks
created
Gas Monitors
Each
PLC Specifications
Specifications
Model
Measuring Ranges
T/H* Sensor
Alarm Output
Analog Output
Interface
Power Supply
Enclosure Size
Enclosure Casing
Weight
S905
S935
S945
Option *
Option *
Option *
4 - 20 mA
4 - 20 mA and 12 to 24 V
4 - 20 mA and 12 to 24 V
RS485
RS485
RS485
24 VDC
24 VDC
24 VDC
2.5 x 5.1
850 g
850 g
1.1 kg
Model
Sensor Channels
Digital Alarm Inputs
Alarm & Control Relays
Analog Inputs
Analog & Control Outputs
Expansion I/O
Data-storage
Communication
Power Supply
Dimensions
R1000 Series
Up to 12
Up to 10
Up to 22
Up to 13
Up to 6
Up to a maximum of 128 I/O
13,000 data points
Serial: RS232/ RS485 (Selectable)
ModBus: Supports MODBUS protocol, Master/Slave
DC 24V
W3.78 x H3.78 x D2.52 (96 x 96 x 64 mm)
Features:
Centralized control from the PC or decentralized control from individual monitors
Specialized application specific software is available on request
Features:
Centralized control from the PLC or decentralized control from individual monitors
Specialized application specific software is available on request
20
Features:
Odor Monitor
Applications:
OMX-SRM
Finding odor source at factories, incinerator, plants, or effluent treatment facility
OMX-ADM
Evaluation for deodorizing at hospitals or nursing homes
Suitable for putrid odor such as ammonia
OMX-TDM
TVOC measurement for monitoring IAQ condition
Specifications
Model
OMX-ADM
Two Semiconductor Gas Sensors
Sampling Method
Object Gas
Odor Strength Level
Classification
Power Supply
Memory Capacity
Storage Temperature
Operating Temperature
Dimensions
Weight
21
OMX-SRM
Detection Method
OMX-TDM
Hydrogen, Sulfide,
Methyl Mercaptan,
Ammonia, etc
0.0 to 999
0 to 999
Class 0 to 90
n/a
Features:
The
ANSI/ASHRAE 110 test is a method of testing the performance of laboratory fume hoods.
Kanomax Dif-Kit tracer gas hardware is ideal for use in performing the Tracer Gas test in
accordance with ANSI/ASHRAE Standard 110-1995.
inserted
Test-Mannequin and the vapor analyzer for the tracer gas test are available
Face velocity measurement data can be stored and downloaded with Anemometer
Dif-Kit
includes tracer gas diffuser, nozzle assembly, in-line flow meter, tank regulator, and 20
ft of tubing
Dif-Kit
Flow Meter
Regulator
AS 110-1995 Ejector
Specifications
Model
Dif-Kit
Critical Orifice
Regulator
Flow Meter
Pressure Gauge
0 to 60 psi
Vapor Analyzer
The Vapor Analyzer is factory calibrated for Sulfur Hexafluoride (SF6).
Response time is less than 10 seconds to 90% response with a stable
maximum concentration in less than 30 seconds.
Specifications
Type
Sample Flow
Sample Cell Volume
Gas Purge
Concentration Alarm
Interface
Power Supply
Dimensions
Vapor Analyzer
Weight
22
Applications
Sound and
Vibration Meters
Features:
Lightweight and compact design
Equipped with highly sensitive electret condenser microphone
Large 4 digit display with 0.1 dB resolution with backlighting
Specifications
Model
4431
Parameters
Ranges
Weighting
A, C and Z
Time Response
Fast or Slow
Microphone
Standards
Power Supply
Accessories
AC-1026:
ACBC-0046-3:
ACBC-0046-5:
ACBC-0071:
ACNA-0038W:
ACNA-0038:
ACNA-0038F:
ACNA-0038R:
ACNA-0333:
AC adapter
Microphone Cable (3m)*
Extension cable (5m)*
BNC-Pin Cable
Data processing software
Program card (1/1, 1/3 octave analyzer)
Program card (FFT analyzer)
Program card (Real Sound Recording)
Tripod
*Additional cable lengths available
Sound Calibrator
Sound Calibrator Model AC2127 implements stable and highprecision calibration by its feedback control function with
temperature compensation.
Calibrator Specifications
Model
Microphone sizes
AC2127
1 inch and 1/2 inch (1/2 inch microphone adapter is included)
94dB (+/-0.3dB)
1000Hz (+/-0.1%)
IEC 60942: 2003 Class 1
JIS C1515: 2004 Class 1
Power Supply
2 x AA Batteries
Pistonphone
Model AC2124A is a standard sound source, which emits
124dB-SPL pure sine tone at 250Hz for calibration of sound
level meter.This is used for precise calibration of sound level
meter provided with 1-inch, 1/2-inch and 1/4-inch condenser
microphones.
Pistonphone Specifications
Model
Sound Pressure Level
Accuracy
AC2124A
124dB
+/- 0.2dB
Frequency
Power Supply
4 x AA Batteries
24
Features:
Wide
Wide
High
Specifications
Model
4156N
4158N
Nominal Diameter
Release Voltage
Pressure Sensitivity
4160N
4152N
4153N
7147A
7312
7313
1/2 inch
-56dB (1.6mV/Pa)
-48dB (4.0mV/Pa)
-32dB (25.1mV/Pa)
-26dB (50.0mV/Pa)
-36dB (15.8mV/Pa)
-38dB (12.5mV/Pa)
Polarization Voltage
Frequency Characteristics
7146
1/4 inch
0V
20Hz to 40kHz
20Hz to 100kHz
20Hz to 10kHz
168dB
150dB
130dB
140dB
135dB
18dB
17dB
<0.7dB/C
<0.01dB/C
45dB
20Hz to 20kHz
20Hz to 10kHz
23dB
<0.01dB/C
<0.009dB/C
20Hz to 20kHz
20Hz to 10kHz
20Hz to 40kHz
20Hz to 20kHz
140dB
20dB
<0.009dB/C
DC15 to 28V
Constant current
0.5 to 4mA
Connector
SMB connector
Dimensions
0.27" x 1.9"
BNC connector
0.5 x 2.9
0.5" x 3.1"
0.5 x 2.9
Specifications
Model
7012
Nominal Diameter
Release Voltage
7013
7016
1/2 inch
7017
1/4 inch
7116
7118
1/6 inch
1/8 inch
-72dB
(0.25mV/Pa)
-20dB
(100.0mV/Pa)
-26dB
(50.0mV/Pa)
-28dB
(39.8mV/Pa)
-26dB
(50.0mV/Pa)
20Hz to 20kHz
20Hz to 10kHz
20Hz to 10kHz
20Hz to 40kHz
20Hz to 20kHz
-36dB
(1.58mV/Pa)
-38dB
(12.5mV/Pa)
-49dB
(3.5mV/Pa)
-58dB
(1.3mV/Pa
-60dB
(1.0mV/Pa)
10Hz to 40kHz
10Hz to 20kHz
20Hz to 100kHz
20Hz to 20kHz
20Hz to 10kHz
Polarization Voltage
Frequency Characteristics
160dB
19dB
164dB
21dB
34dB
Dimensions
25
7023
7047A
7146NL
1/2 inch
0V
170dB
46dB
45dB
Temperature coefficient
Preamplifier Type
7022
1 inch
200V
7020
140dB
65dB
2dB
146dB
11dB
13dB
160dB
134dB
20dB
15dB
<0.007dB/C
Type 4212
0.5" x 0.5"
Type 4116
0.3" x 0.4"
0.2 x 0.4
Type 4022
0.1 x 0.2
0.9 x 1.1
0.9 x 0.7
Type 4212
Type 4011
0.5 x 0.6
Features:
Compact size maximizes technician mobility
Magnetic accelerometer increases measuring accuracy and ease-of-use
Includes
Specifications
Measurement Range
Acceleration
Velocity
Displacement
2 to 2000 m EQp-p
Frequency Range
Acceleration
Velocity
3Hz to 10kHz
10Hz to 1kHz (Compliant with JIS B0907-1989)
Displacement
Readings
10 to 400Hz
RMS, Peak, EQ Peak, EQ Peak-to-Peak
Output
AC Output
Headphone Output
Interface
Operating Environment
Temperature
Humidity
Power Supply
-10 to 50C
30% to 90% (no condensing)
Accessories
AC-1046:
AC7812B:
ACPV-0148:
ACPV-5050:
ACNA-0134:
ACSS-22M:
ACBC-0071:
ACBC-0116-3:
ACNA-0116:
ACBC-0026:
AC adapter
Pickup
Spare Magnet
Strong Magnet
Auscultation Rod
Stud
BNC-Pin Cable
Extension Cable 3m*
Data processing software
Communication Cable (RS232)
*Additional cable lengths available
ACCM-393
Approx. 100k
Measurement Sensitivity
20mV/m/s2 (200mV/G)
Measurement
Range
Acceleration
Displacement
1 to 1000p-p
Frequency
Response
Acceleration
5Hz to 1kHz
Displacement
10Hz to 200Hz
Accuracy
Filter
Output
Power Supply
Dimensions
26
Applications
Dust Monitors
27
Dust Monitors
Measures
Real-time
measurements
concentration
of
dust
Complete
Dust Monitors
Specifications
Model
3521 / 3522
3443
Measuring Method
Piezobalance
Light Scattering
0.1 to 10 m
Measuring Range
1.0 L/min
1.0 L/min
500 measurements
100,000 measurements
RS232C
USB
Analog Output
n/a
0 to 1 V / Pulse / Alarm
Power Supply
Flow Rate
Datalogging
Interface
Dimensions
Weight
28
Dust Monitors
Data
Specifications
Model
3521
3522
Measuring Method
Particle Size Range
Measuring Range
Piezobalance
0.1 to 10 m
1.0 L/min
500 measurements
Interface
Power Supply
Dimensions
Weight
Software Included
Flow Rate
Datalogging
Accessories
0.1 to 2.5 m
RS232C
Ni-MH Battery or AC 100 - 240 V
W2.6 x H7.1 x D5.9
3.9 lbs (1.75 kg)
3521-01:
3521-02:
3521-03:
3521-04:
3521-05:
3521-06:
3521-07:
3521-08:
3521-20:
DPU-S245:
TP-202L:
Applications:
Monitoring milling operation
Monitoring honing
Monitoring boring operation
29
Dust Monitors
Complete
Specifications
Model
Measuring Method
Particle Size Range
Measuring Range
Flow Rate
Datalogging
Interface
Analog Output
Power Supply
Dimensions
Weight
3443
Light Scattering
0.1 to 10 m
0.001 to 10.000 mg/m3
1.0 L/min
100,000 measurements
USB
0 to 1 V / Pulse / Alarm
AA Battery or AC 100 - 240 V
W6.7 x H2.7 x D4.3
2.9 lbs (1.3 kg)
Software Included
Accessories
3442-01:
3442-02:
3442-04:
3442-05:
3442-10:
3431-03:
6113-02:
CX-440:
Features:
Operates continuously with no moving parts
High efficiency sampling rate for fine pulverized dust
Industrial construction
Cyclone removes to facilitate periodic cleaning
Two manometer tap points to monitor draft pressure
Accessories
Applications:
All
C8406:
C8408:
C8407:
C3101:
C3102:
C3103:
C3104:
C5019:
C5020:
Probe (2 m)
Probe (3 m)
Probe Extension (10 ft)
Inlet Nozzle 1/2 (12.7 mm)
Inlet Nozzle, 5/8 (15.9mm)
Inlet Nozzle, 3/4 (19.0 mm)
Inlet Nozzle, 3/8 (9.5 mm)
Heater Jacket, 100W, 240 Volt
Heater Jacket, 100W, 110 Volt
30
Applications
Particle Counters
31
Cleanroom Certification
Filter Testing
Particle Counters
Particle Counters
Lightweight
handheld
particle
counter with environmental sensors
Small
footprint,
lightweight
portable particle counter available
with two different flow rates
Simultaneous measurements of
Simultaneous measurements of
5 particle sizes
accuracy measurement
Store
up
measurements
to
10,000
Data
logging
measurements
Light Source
Counting Efficiency
up
to
Small
enclosure
touch
displays
all
simultaneously
Store
up
measurements
screen LCD
measurements
to
10,000
3886
Stainless
PC
Includes
3887
footprint,
Large
500
Flow Rate
Particle Sizes
6 particle sizes
PC
Specifications
Model
Complete
with
Quick-start
guide, AC adapter, zero filter,
Isokinetic probe with 79 inch
(2 m) tubing, inlet nozzle, data
processing software, memory
card, 2 rolls of cleanroom-grade
printer paper, Li-ion battery, and
calibration certificate
Laser Diode
Laser Diode
Laser Diode
50+/-20% @ 0.3 m
50+/-20% @ 0.3 m
50+/-20% @ 0.3 m
Coincidence Loss
10,000 measurements
500 measurements
10,000 measurements
RS232C or USB
RS232C or USB
Datalogging
Interface
Option Sensor
Enclosure
Power Supply
Dimensions
Weight
n/a
Molded Plastic
Molded Plastic
Stainless Steel
Particle Counters
3887
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Datalogging
Interface
Enclosure
Power Supply
Dimensions
Weight
10,000 measurements
RS232C or USB
Molded Plastic
4 x AA Batteries or AC 100 - 240 V
W4.4 x H7.8 x D2.8
1.5 lbs (680 g)
Software Included
Accessories
3887-02:
3887-07:
DPU-S245:
TP-202L:
CX-440:
301APK:
Carrying Case
Printer Cable
Portable Thermal Printer
Rolled Printer Paper (10 rolls)
Tripod
Intl. Plug Adapter Kit
Coincidence Loss
Datalogging
Interface
Optional Sensor
Enclosure
Power Supply
Dimensions
Weight
33
3886
0.3 / 0.5 / 1.0 / 3.0 / 5.0 m
500 measurements
RS232C or USB
Air Velocity / Temperature, Humidity
Molded Plastic
4 x AA Batteries or AC 100 - 240 V
W4.5 x H8.3 x D2.8
2.2 lbs (980 g)
Accessories
0842:
0843:
0843-01:
3886-02:
3886-04:
S388-61:
3886-07:
3886-08:
DPU-S245:
TP-202L:
CX-440:
Carrying Case
Particle Counters
Specifications
Model
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Zero Count Level
Datalogging
Interface
Optional Sensor
Enclosure
Power Supply
Dimensions
Weight
3910
3905
0.3 / 0.5 / 1.0 / 3.0 / 5.0 / 10.0 m
50.0 L/min
28.3L/min
Laser Diode
50+/-20% @ 0.3 m
Less than 10% at 500,000 particles/ft3
Less than 1 count per 5 minutes
10,000 measurements
Ethernet, USB, Memory card slot (MMC)
Air Velocity, Temperature, Humidity
Stainless Steel
Li-ion Battery or AC 100 - 240 V
W7.9 x H8.1 x D7.9
14.2 lbs (6.44 kg)
Model 3910/05
Model 3900
6531-2G-P
Probe Type
Uni-Directional
Air Velocity
2 to 6000 fpm
Temperature
Relative Humidity
-4 to 158F
2.0 to 98.0% RH
Accessories
6531-2G-P:
3910-01:
3910-02:
3910-03:
3910-04:
3910-05:
3910-08:
3910-09:
CRVAL:
Zero filter
Printer paper
Validation IQ/OQ Document
34
Features:
Particle Counters
Complete with
Measuring Priciple
Software Included
Specifications
Model
3800
Measuring Object
Particle Sizes
0.015 to 1.0 m
Flow Rate
0.7 L/min
Light Source
Laser Diode
100% @ 0.05 m
More than 50% @ 0.015 m
Counting Efficiency
Coincidence Loss
Alcohol Supply
Datalogging
Interface
Isopropyl Alcohol
10,000 measurements
USB
Power Supply
Dimensions
Weight
Applications
Leakage Testing
Accessories
3800-01:
3800-02:
3800-03:
3800-04:
3800-05:
3800-06:
35
AC Adapter
Zero Filter
Alcohol Bottle
Storage Cap
Alcohol Cartridge
Spare Felt and Wire Mesh
3800-07:
3800-08:
3800-10:
3800-11:
DPU-S245:
TP-202L:
Communication Cable to PC
Carrying Case
Sampling Probe with 1m Tubing
Printer Cable
Portable Thermal Printer
Rolled Printer Paper (10 rolls)
Sampling Probe
Kanomax particle sensors with analog output are designed to fit into your existing
monitoring system, or they can be used as a stand-alone unit to monitor a critical area
when connected to an alarm or controller. The Kanomax particle sensor is available
with a 1.0 CFM flowrate and also comes in two different ranges: 0.3 and 0.5 microns or
0.5 and 5.0 microns.
Features:
Light scattering particle sensor
1.0 cfm flow rate (28.3 lpm)
Analog output makes it easy to integrate into existing systems
0.3 or 0.5 micron sensitivity
Compact body with stainless enclosure
Fully compatible with the Kanomax Cleanroom Monitoring System as
Applications:
Cleanroom Facility Monitoring
Food Industry
Aerospace
Hospital Surgical Rooms
Specifications
Model
Measuring Object
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Zero Count Level
Interface
Enclosure
Power Supply
Dimensions
Weight
3716A
3717A
Airborne Particle Matter
0.3 / 0.5 m
0.5 / 5.0 m
1.0 cfm (28.3 L/min)
*External vacuum source is required
Laser Diode
50% @ 0.3 m
50% @ 0.5 m
Less than 5% at 500,000 particles/ft3
< 1 count per 5 minutes
RS485 & 4-20mA
Stainless Steel
9 - 28V (AC adpter supplies 12V)
W6.3 x H5.1 x D3.9
3 lbs (1.5 kg)
Example Configuration: Shows 6 sensors connected to datalogger via the 4-20 mA output. Its easy to connect them to
a datalogger or any other device that will accept an analog signal. Note that a vaccuum source is required for the sensors.
Vacuum Pump
Connect up to 6 particle sensors
4-20mA connection to
datalogger or acquisition system
36
Particle Sensors
PM Sensor
Supply Voltage
12VDC
Operating Temperature
-10 to 45C
Operating Humidity
Dimensions
Weight
120g (approx)
120g (approx)
130g (approx)
Aerosol Sensor Unit - Particulates of 0.5 microns or larger can be monitored. The aerosol sensor unit
can be used to keep optimum driving of filtering equipment related to a clean room depending on
actual condition of cleanliness level.
Features:
Unique air sampling method using heater to generate updraft, preventing choked flow. Suc-
PPD42NJ
Stable and sensitive detection for particulates of 0.5 microns and larger can be monitored.
Long life laser. 20,000 hours
Compact size, low cost
PPD60PV
Air Purifier
Clean booth/small
Air Conditioner
Clean Unit
Ventilation
Vaccuum Cleaner
Specifications
Model No.
Detectable Particle Size
PPD42NJ
Approx. 1 m & larger
Supply Voltage
Output Method
Dimensions
Weight
37
AES1-05N
12VDC
0 to 45C
0 to 40C
30 to 80% RH
(no condensation)
Operating Temperature
Operating Humidity
PPD60PV
Digital
Digital or Analog
Digital
59x45x22 mm
88x60x20 mm
90x90x23 mm
24 g
36 g
130 g
AES1-05N
Aerosol Monitor
Features:
Stable
Easy-to-read
Alarm
Link
Applications:
Monitor cleanrooms
Pharmaceutical / Semiconductor / Food Industry
Wall-mount Monitor
Specifications
Model
Monitoring Particle Size
Display
Sampling Method
Optics
AES-1000
0.5 microns
10 x LED lights shows equivalent of Class;
100(ISO 5), 1,000(ISO 6), 2,000, 3,000,5,000,10,000(ISO 7),
20,000, 30,000, 10,000, 100,000(ISO 8)
Updraft airflow generated by built-in heater enables air sampling
Semiconductor Laser, 20,000 hour life
Alarm Display
Alarm Output
Interface
Supply Voltage
Operating Temp/Humidity
Ethernet X 1 port
12VDC+/-10% 500mA
0 to 40 deg. C, 30 to 80%rh
PC Software is Included
38
Features:
Compact stainless enclosure with sensors
Multi-parameter
Particle Sensors
Features:
Light scattering particle sensor
Durable
No
Specifications
Model
Measuring Object
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Zero Count Level
Interface
Enclosure
Power Supply
Dimensions
Weight
3714
3715
Airborne Particle Matter
0.3 / 0.5 m
0.5 / 5.0 m
0.1 cfm (2.83 L/min)
*External vacuum source is required
Laser Diode
50% @ 0.3 m
50% @ 0.5 m
Less than 5% at 1,000,000 particles/ft3
< 1 count per 5 minutes
RS485
Stainless Steel
DC24V (Supplied from the 3770)
W5.0 x H2.8 x D1.6
1.1 lbs (500 g)
Specifications
Features:
Model
Measuring Object
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Zero Count Level
Interface
Enclosure
Power Supply
Dimensions
Weight
3716A
3717A
Airborne Particle Matter
0.3 / 0.5 m
0.5 / 5.0 m
1.0 cfm (28.3 L/min)
*External vacuum source is required
Laser Diode
50% @ 0.3 m
50% @ 0.5 m
Less than 5% at 500,000 particles/ft3
< 1 count per 5 minutes
RS485 & 4-20mA
Stainless Steel
9 - 28V
W5.9 x H4.7 x D3.9
3 lbs (1.5 kg)
Specifications
Features:
0.2 m sensitivity particle counter
Digital and analog outputs are available
Analog output for Multiplexer
39
Model
Measuring Object
Particle Sizes
Flow Rate
Light Source
Counting Efficiency
Coincidence Loss
Zero Count Level
Interface
Power Supply
Dimensions
Weight
3792-01
Airborne Particle Matter
0.2 / 0.3 m
0.1 cfm (2.83 L/min)
Laser Diode
50% @ 0.2 m
Less than 5% at 1,000,000 particles/ft3
< 1 count per 5 minutes
RS485 / 4 to 20 mA for Multiplexer
AC 100 to 240 V
W4.6 x H5.3 x D6.7
6.6 lbs (3 kg)
Interface Box
Converts analog input to digital
Supplies power to the sensor
Specifications
Model
Input
Output
Power Supply
Dimensions
Weight
3772-02
4 to 20 mA / 0 to 1 V / 1 to 5 V
RS485
DC24V (Supplied from the 3770)
W5.5 x H3.1 x D1.6
1.1 lbs (500 g)
Distributors
Features:
Features:
Specifications
Supplies
Model
# of Channels
Interface
Power Supply
Dimensions
Weight
3770
8
RS485
AC 85 to 132 V or AC 170 to 267 V
W11.8 x H3.9 x D7.9
6.6 lbs (3 kg)
Map
Trend Graph
System Examples
Industrial Cleanroom
Bio-medical Cleanroom
40
Aerosol Research
Instruments
Industrial hygiene
Nanosampler
Condensation
Particle Counter
Air pollution
Ambient air quality research
Earth sciences
Environmental research
Climate change research
41
Uses
Bipolar
Can be used in two modes: Single diameter count mode: to get a total count
Operation:
Sampled aerosol is charge-conditioned using a
non-radioactive, bipolar charger which brings
the particles to steady-state charge distribution.
Particles are subsequently sorted according to their
electrical mobility in a differential mobility classifier
(DMA). Classified particles are detected and counted
downstream using a condensation particle counter
(CPC).
Specifications
Model
3300
Measuring Modes
Size Range
0.2LPM: 14 channels
0.4LPM: 27 channels
Scan Resolution
Scan Time
Concentration Range
Flow Rate
Bipolar Charger
Condensing Fluid
Isopropyl alcohol
Display
Color touchscreen
Dimensions
Weight
Accessories
3300-05:
3300-08:
3300-09:
3300-10:
42
Applications:
Mass distribution measurements
Particle density research
Monodisperse aerosol generation
Features:
Lightweight, Desktop Unit
Measurement software, communication cable, extension board, extension
Specifications
Model
Particle Mass Range
Maximum Rotation Speed
Maximum Voltage
Rotating Cylinder Dimensions
Sampling Flow Rate
Power Supply
Dimensions
Weight
APM-3601
Control Unit
43
Features:
Measures black carbon concentration in the air in real time
Preprocessing of sample air improves measurement accuracy
Automatic filter feed enables continuous measurement for extended periods
Advanced detection sensitivity enables measurement in low concentrated areas
Complete with inlet heater, pump, pump controller, 2.5 m-cut impactor, software,
Specifications
Model
Measurement Method
Light Source
Lowest Detection
3130
Light Absorption Method
LED Wavelength 565 nm
0.05 g/m3 @1 min @0.8 L/min
0.8 L/min
Fiberglass Filter (Length: 25 m)
PC Interface
USB
Power Supply
Dimensions
100 VAC, 6A
W 17 x H 8.7 x D 13.9
Weight
System Diagram
Features:
Particle classification as small as 0.1 m
5 stages of PM10, 2.5, 1.0, 0.5, 0.1 and backup filter
Large sample flow rate of 40 L/min
Includes 1 box of quartz fiber filter (55mm x 100 pc.), and 5 sets
of PM0.1 cartridge
Specifications
Model
Classification Method
3180
Inertial Collection
Classification Range
Absorption Material
Quartz Fiber Filter: PM 10, PM 2.5, PM 1.0, PM 0.5, and Backup fiter
SUS fiber: PM0.1
40 L/min
Dimensions
3.5 x 8.3
Weight
44
Dust Sentry
Aerosol Research Instruments
Features:
Real time particle monitoring, Measures and reports data in 1 minute intervals
Accurately measures TSP, PM10, PM2.5 or PM1
On board data storage for up to 15 years of data
Web-based and GSM data retrieval and alerts
Gravimetric filter
Option to integrate weather, wind, temp/RH sensors, and sirens
Tough weatherproof enclosure with solar shielding for hot climates
Quick installation and relocatable
Datalogging and configuration software included
Specifications
Model
DS 10
Measurement Technology
DS 25
DS 1
Range
0-2000 g/m3
Accuracy
PM 10
PM 2.5
Sample Flowrate
PM 1.0
2.0 LPM
Inlet
Heated
Alarm
Datalogging
Reference Filter
25mm GF filter
Outputs
Power Requirements
Enclosure
Weight
<12kg
Accessories
45
DS SC10:
DS SC25:
DS SC1:
DS R39:
DS R40:
DS O12:
PM10 Cyclone
PM2.5 Cyclone
PM1.0 Cyclone
DS AUX:
DS 420:
DS R47:
DS R1:
DS R25:
DS CM:
DS R10:
DS R31:
DS R20B:
DS R34:
DS R56:
CAL R4:
Auxillary Module
4-20mA Module
47mm AnalysisFilter
Gill WindSonic Sensor
Vaisala WTX520 Weather Transmitter
Control Module
Sampling Pump
PM Filters
Flowmeters (x2)
PM Purge Pump
Zero Filter & Flow Assembly
Factory Calibration PM
Insulated
Specifications
Model
AQM60
Features:
Power Supply
Enclosure
Dimensions
Weight
Sensor
Range (ppm)
Accuracy
Resolution
Ozone
GSS
0 - 0.150
0.001 ppm
Power
2.9 W
Nitrogen dioxide
GSS
0 - 0.200
<+/- 15%
0.001 ppm
12.3 W
Carbon monoxide
GSS
0 - 100
<+/- 5 ppm
0.1 ppm
2.5 W
Sulphur dioxide
GSS
0 - 10
0.01 ppm
2.5 W
Non-methane hydrocarbon
GSS
0 - 25
0.1 ppm
2.5 W
VOC isobutylene
GSS
0 - 25
<+/- 10%
0.1 ppm
2.5 W
VOC isobutylene
PID
0 - 20
<10 %
0.01 ppm
1.5 W
Hydrogen sulphide
GSS
0 - 10
0.01 ppm
2.5 W
Carbon dioxide
NDIR
0 - 2,000
<40 ppm + 3%
1 ppm
1.0 W
Features:
Available for variety of sample particles
Long time operation
Stably generated particle concentration
Easy control on the concentration level
Specifications
Model
Particle Sizes
Density
Flow Rate
Power Supply
Dimensions
Model 3211
3211
3216
Less than 20 m
0.2 to 10 m
20 g/m3
30 L/min
AC100V, 50/60Hz
W 6.7 x H 17.5 x D17.7
Model 3216
46
Applications
Mass Spectrometry
Food analysis
Forensic Science
Medical
Environmental analysis
Mass Spectrometry
47
Mass Spectrometry
Features:
High resolution and compact time of flight mass spectrometer
Impure substance analysis in gases with the detection limit of 10ppb
Onsite detailed accurate analysis
Applications:
Food analysis
Particle analysis
Environmental analysis
Forensic: detection of forged paintings
Medical: blood test, hair analysis etc
Specifications
Resolution
Dynamic Range
10 bit
2GS/s
Dimensions
Weight
48
Automotive
Testing
Instruments
Amenity Manikin System
Cabin Comfort Test Rig
Features:
4 mannequins measure simultaneously; understanding the entire cabin
Wireless connection brings easy operation
Graphical software for both real-time measurement and data retrieval
Excel compatible data output as well as saved graphical data for review
Amenity Manikin
Air Velocity
4
12
20
36
Temperature
12
33
33
78
Humidity
1
0
1
2
Radiant Heat
3
5
4
12
Mannequin Specifications
Height
Weight
Material
Sensor Specifications
Air Velocity Ranges
Accuracy
Temperature Ranges
Accuracy
Humidity Ranges
Accuracy
Radiant Heat Ranges
Accuracy
Wavelength
49
Measurement Software
CLT-APC-NPP
Features:
Automatic Pressure Control
Specifications
Model
CLT-MPC
Nozzle Specifications
CLT-MPC
Fan Speed
Pressure Measurement Accuracy
Leakage Flow Measurement
Accuracy
Cabin Pressure Preset Ranges
Automatic Pressure Control
Negative Pressure Plenum
Small Transport Cart
Power Supply
Duct Size
Dimensions
CLT-MPC-NPP
CLT-APC
CLT-APC-NPP
(5 to 499 Pa)
120/240 V, 1 phase
16.4 ft x 8 inches (5 m x 203 mm)
Small Transport Cart: W 22.5 x H 23.5 x D 54
Large Transport Cart: W 27.5 x H 42 x D 58.5
Nozzle
F
G
H
D
E
Inlet Diameter
0.590 (15 mm)
1.122 (28.5 mm)
2.204 (56 mm)
3.543 (90 mm)
6.023 (153mm)
Flow Ranges
2.5 to 10 cfm (1.2 to 4.8 l/s)
8.5 to 36 cfm (4 to 17 l/s)
32 to 142 cfm (15 to 67 l/s)
53 to 296 cfm (25 to 140 l/s)
190 to 847 cfm (90 to 400 l/s)
Features:
Versatile and Portable unit
High output, non-toxic, water-soluble smoke
System
Nozzle
Specifications
Model
Smoke Output
Smoke Particle Size
Warm Up Time
Power Supply
Dimensions
Weight
8304
15 to 80 L/min
0.3 to 1.0 m
4 minutes
AC100V, 550W
W11.8 x H13.8 x D25.6
61.7 lbs (28 kg)
50
Applications:
Non-contact velocity measurements
Wind tunnel studies
Measurements in combustion, combustor
Features:
Specifications
Model
Velocity Ranges
Laser
Focal Distance
Focal Point Size
Probe Size
Shift Frequency
Signal Processing
Max. Data Rate
Smart LDV II
-40 to 100 m/s
*Ask for above 100 m/s
Laser Diode: = 660 nm, Optical power: 60 mW
150, 200, 250, 300, 350, 400mm
0.13 mm x 1.3 mm
61 mm x 312 mm
0.01 to 10 MHz (1-2-5 steps)
8-bit FFT (512, 256, 128 points)
16000 Data/sec
FLUOSTAR
Applications:
51
Features:
Specifications
Multi-phase flows
Minimal photobleaching
Substrate Material
Refractive Index
Temperature
Fluorescence dye
Density
Near-wall flows
Size Uniformity
Stereo PIV
No swelling or shrinking
Sizes
Features:
Highly responsive 2-channel flow measurement
Software-controlled probe calibration, measurement, analysis, and display
Variety of probes to meet individual measuring needs
Automatic probe resistance measurement and setup by the built-in CPU
Up to 4 units connected for 8 channels
Specifications
Model
IHW-100
Composition
Bridge Ratio
Approx. 10:1
Probe Current
Up to 500 mA
Frequency Response
Temperature Compensation
32 to 122F (0 to 50C)
with a copper-constantan thermocouple
Power Supply
Dimensions
Option Probes
AC 90 to 250V
W 16.9 x H 3.9 x D 11.8(430 x 99 x 300 mm)
Weight
BubbleMaster
Features:
Measure bubble size and velocity of each bubble
Applicable for non-conductive fluid
Software Included
Applications:
Cavitation Research
Specifications
Model
Sensor Type
BubbleMaster
S-TOP: Single tip optical fiber
T-TOP: 2 tips optical fiber
F-TOP: 4 tips optical fiber
From 1.0mm
Applicable Velocity
Up to 5.0 m/s
52
Applications:
Wind Tunnels
NIST traceability
Research and development
Specifications
Type
Velocity Range
Air Temperature
Power Supply
Dimensions
Open Jet
0.3 to 30 m/s
Ambient
Single phase 220-240 V 50/60 Hz
*Other Voltages can be supplied to suit country requirements
Length: 5500 mm (basic setup)
53
Wind Tunnels
Applications:
Verification and calibration of anemometers and pitot tubes
NIST traceability
Research and development
Specifications
Type
Velocity Range
Air Temperature
Cross Section
Power Supply
Dimensions
0.5 to 50 m/s
Ambient
150 x 150 mm
Tri-phase 380V 50Hz 6KVA
W3000 x H1600 x D1000 mm
Test Section
Catalog Index
Aerosol Particle Mass Analyzers .........................................................................
Airflow Transducers ............................................................................................
Ambient Air Quality Monitor ..............................................................................
Amenity Manikin .................................................................................................
Black Carbon Monitor .........................................................................................
Cabin Leakage Testers .........................................................................................
Capture Hood ......................................................................................................
Cleanroom Monitoring System ...........................................................................
Dif-Kit Fume Hood Diagnostic Tools ....................................................................
Dust Monitors ......................................................................................................
Dust Sentry ..........................................................................................................
Flow Grids ............................................................................................................
Fluidized Particle Generator ................................................................................
Fluorescent Seeding Particles .............................................................................
Flyash Sampler .....................................................................................................
Gas Monitors .......................................................................................................
Handheld Anemometers .....................................................................................
Handheld Condensation Particle Counter ...........................................................
High Temperature Anemometer .........................................................................
IAQ Monitors .......................................................................................................
Inertial Filter ........................................................................................................
Intelligent Hot Wire Anemometer ......................................................................
Multi-channel Anemometers ..............................................................................
Networked Gas Sensor Systems ..........................................................................
Odor Monitor .......................................................................................................
Particle Counters .................................................................................................
Piezobalance Dust Monitor .................................................................................
Pitot Static Tubes .................................................................................................
Portable Aerosol Mobility Spectrometer ............................................................
Rotating Vane Digital Anemometer ....................................................................
Smoke Generator .................................................................................................
Smart LDV ............................................................................................................
Sound Meter ........................................................................................................
Time of Flight Mass Spectrometer ......................................................................
Vapor Analyzer ....................................................................................................
Vibration Meter ...................................................................................................
Void Fraction Measuring System .........................................................................
Wind Tunnel .........................................................................................................
Page 43
Page 15
Page 46
Page 49
Page 44
Page 50
Page 9
Page 39-40
Page 22
Page 27-30
Page 45
Page 11
Page 46
Page 51
Page 30
Page 19-20
Page 3-8
Page 35
Page 12
Page 17-21
Page 44
Page 52
Page 13-16
Page 20
Page 21
Page 31-35
Page 29
Page 10
Page 42
Page 8
Page 50
Page 51
Page 23-25
Page 47-48
Page 22
Page 26
Page 52
Page 53-54
Distributed by: