Measuring range:
10-100...4000-40000 l/h water
0.3-3.0...110-1100 m/h air
(20C, 1.013 bar)
OO
OO
OO
OO
OO
OO
Options:
Contacts, analogue output with HART,
PROFIBUS-PA, Foundation Fieldbus, counter
1/08-2013
Full Metal Variable Area Flow Meter and Counter Model BGF
Application
The BGF meter is suitable for flow measurement of liquid or
gaseous products in pipes. The special advantage is that it
can be used for all directions of flow. It shows the current flow
rate in volume or mass per unit in time.
Areas of application
Flow measurement, dosing, monitoring, adjusting and control
of liquid and gaseous products. The meters design makes it
ideal for processes under difficult and adverse operating
conditions.
The devices are available with additional electrical equipment
for process monitoring and control.
OO A
Accuracy
Liquid/Gas:
Additional inaccuracy
by transmitter (ES):
Repeatability:
Schutzart:
www.kobold.com
1/08-2013
Description
Inside the flow tube, there is a star guided float which works
towards a spring. An annular gap is produced between the
cone-shaped magnet system and the meter ring in case of
flows other than zero. The position of the magnet system
depends on the resulting force of all forces acting upon it.
These forces comprise the flow force, a spring force acting
opposite to the flow force, and the buoyancy and weight
force significant for the measurements in case of vertical
installation. Each position of the magnet holder corresponds to
a flow value measured during calibration, which is transferred
to a scale. The BGF flow meter consists of a meter tube with
connections, a meter ring, and a conical magnet holder. By
means of a magnet, the position of the magnet system is
transferred to an encapsulated follow magnet, which has
been fitted to a pointer axle. The position of a second annular
follow magnet fitted on the pointer axle is transferred to the
scale by means of the pointer.
Technical data
Sensor
Materials:
Process connection:
Nominal pressure:
Process temperature:
Ambient temperature:
Full Metal Variable Area Flow Meter and Counter Model BGF
with Profibus-PA
ES
Power supply:
Outputs:
Currency:
Binary 1 and 2:
Input Binary:
Ambient temperature:
14 - 30 VDC
passive, galvanically isolated
4-20 mA
Ui=30V, Ii=20mA, Pi= 100mW
Counter reset (only for ES with
counter module)
-40C...+70C
Certifications
and certificates
1/08-2013
Inductive
www.kobold.com
Full Metal Variable Area Flow Meter and Counter Model BGF
BGF-S =
stainless steel
tube
BGF-P =
stainless
steel tube,
PTFE-liner
Measuring
range water
[l/h]
10 - 100
16 - 160
25 - 250
40 - 400
60 - 600
100 - 1000
160 - 1600
250 - 2500
400 - 40001)
10 - 100
16 - 160
25 - 250
40 - 400
60 - 600
100 - 1000
160 - 1600
250 - 2500
400 - 40001)
250 - 2500
400 - 4000
600 - 6000
400 - 4000
600 - 6000
1000 - 10000
1600 - 16000
2500 - 25000
1600 - 16000
2500 - 25000
4000 - 40000
Measuring
range air at
20C,
1013 mbar
[Nm3/h]
0.3 - 3.0
0.5 - 4.6
0.7 - 7.0
1.0 - 11
1.7 - 17
3.0 - 30
4.0 - 46
7.0 - 70
11 - 1101)
0.3 - 3.0
0.5 - 4.6
0.7 - 7.0
1.0 - 11
1.7 - 17
3.0 - 30
4.0 - 46
7.0 - 70
11 - 1101)
7.0 - 70
11 - 110
17 - 170
11 - 110
17 - 170
29 - 290
46 - 460
70 - 700
46 - 460
70 - 700
110 - 1100
Connection
size
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 15, (")
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 25, 1"
DN 40, 1"
DN 40, 1"
DN 40, 1"
DN 50, 2"
DN 50, 2"
DN 50, 2"
DN 50, 2"
DN 50, 2"
DN 80, 3"
DN 80, 3"
DN 80, 3"
Pressure
stage
Max.
pressure loss
[mbar]
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
PN 40
on request
110
110
110
120
90
105
130
240
on request
110
110
110
120
90
105
130
240
75
110
130
100
110
120
130
200
110
130
200
Code2)
flange
DIN EN 1092-1
Form B1
15305B H
15305B I
15305B J
15305B K
15305B L
15305B M
15305B N
15305B P
15305B Q
25309B H
25309B I
25309B J
25309B K
25309B L
25309B M
25309B N
25309B P
25309B Q
40317B P
40317B Q
40317B R
50321B Q
50321B R
50321B S
50321B T
50321B U
80331B T
80331B U
80331B V
Code2)
flange
ASME
Class 150 RF
15202R H
15202R I
15202R J
15202R K
15202R L
15202R M
15202R N
15202R P
15202R Q
25203R H
25203R I
25203R J
25203R K
25203R L
25203R M
25203R N
25203R P
25203R Q
40205R P
40205R Q
40205R R
50206R Q
50206R R
50206R S
50206R T
50206R U
80208R T
80208R U
80208R V
www.kobold.com
1/08-2013
Full Metal Variable Area Flow Meter and Counter Model BGF
Flow
direction
Heating1) /
Cooling
Certificates
Display
Scale
Electrical
output
0 = without
1 = 1 inductive
switch
S = aluminium
0 = without
O = top to
K = PP1)
bottom
(to 80C,
1 = with heating
from DN50)
ermeto 12 mm
L = left
to right
P = PTFE
2 = with heating
(BGF-S
DIN-flange
to 150C)
R = right
DN15/PN40
(BGF-P
to left
to 125C)
S = st. steel1)
1)
3 = with heating
U = bottom
ANSI-flange
to top
" Class 150
0 = without certificate V =
1 = Certificate of
compliance with
E =
the order 2.1
H =
2 = Certificate of
compliance with
the order 2.2
B = Inspection
certificate
with material
certificate 3.1
C = Inspection
certificate
with material
certificate 3.2
aluminium,
assembled
at 200C
st. steel
st. steel,
assembled
at distance
up to 200C
2 = 2 inductive
switches
C = 1microswitch
D = 2microswitches
Water
1 = %-scale
2 = measuring
range
Media
4 = %-scale
5 = measuring
range
T = aluminium
with
pressure
Please specify
compensation
mediadata in
plain text (see
below)
W = aluminium
with pressure
compensation,
assembled at
distance up to
200C
6 = transmitter ES with
HART, EExia,
4-20 mA, SIL
7 = transmitter ES with
HART, EExia,
4-20 mA and 2
Namur-switches,
SIL
8 = transmitter ES with
HART, EEx ia,
4-20mA, 1 Namur
switch and 1 pulse
output
9 = electrical
transmitter ES with
Profibus-PA,
EExia
I = 4-20 mA with
HART counter
module
K = electrical transmitters ES with
Foundation
Fieldbus
For the right design of the flowmeter we need the following data:
measuring range with unit, measured media, process temperature and pressure, viscosity,
operating density (liquids), norm density (gases), mechanical connection.
Dimensions [mm]
DN
PN
I. W.
A (aluminium)
A (stainless steel)
15
40
26
74
100
25
40
32
77
103
40
40
46
85
110
50
40
70
98
123
80
40
102
114
140
1/08-2013
Dimensional deviations:
+100 mm with forward advanced display
www.kobold.com
Full Metal Variable Area Flow Meter and Counter Model BGF
Dimensions [mm]
Display: aluminium
149
A
149
149
A
149
250
44,5
149
97
149
250
250
l.W.
97
165,5*
90,5
90,5
90,5
165,5*
165,5*
l.W.
l.W.
97
44,5
44,5
196
250
196
196
68
97
250
97
250
l.W.
81
158*
81
81
158 *
158*
l.W.
97
68
www.kobold.com
1/08-2013
68