Vous êtes sur la page 1sur 117

ONLINE-CATALOGUE

B8/8 Introduction

Metalfree (ADSS cables) and metal-armored (OPGW, OPPW) aerial cables with integrated optical fibres (called optical fibre aerial cables)
are used to transmit information. The information is transmitted by means of modulated light pulses in the interior of the thin optical fibres.
These fibres have a total diameter of approx. 300 m. The optical fibre aerial cables can be stressed upto <!--[if !supportEmptyParas]-->a
limited tensile force without any increase of the optical signal damping in the fibres. However, in the case of a radial force, the optical
damping will increase by bounds. This increase can lead to a reduction of the information flow through the fibres.
The fibres with an additional length are beded in one or several relatively rigid coaxial tubes to avoid inadmissible stress. In the case of
metalfree optical cables the tubes are beded in a supporting structure of aramid fibres. The optical fibre cable is finally covered with an
extruded PE-mantle. The core of the metall-armored aerial cable is covered with one or more layers of Aluminium wires, Aluminium alloy
wires or Aluminium-clad steel wires.
As the optical fibres have to be protected against inadmissible radial forces during and after the installation of optical fibre aerial cables the
fittings at the tension-, suspension- and fixing points have to meet special requirements.
For common conductors and ground wire we use fittings for tension and suspension points which provoke the necessary grippage force by
effecting of a high radial force (for example wedge type tension clamp, suspension clamp). Due to the high pressure sensitivity of optical
fibres beded in the aerial cable these types of fittings are not suitable for optical fibre aerial cables.
The fittings of the RIBE-Optofit-program are designed regarding this high pressure sensitivity. The fittings are especially adapted to this
purpose. The induced radial forces are spread over a larger contact surface (for example dead end) in such a way that the fibres are not
inadmissibly stressed and the necessary grippage forces are achieved. It is impossible to determine standardized accessories for optical
fibre aerial cables as the structure of the different cables is very manifold.
Fittings for optical fibre aerial cables mainly consist of the following group of fittings:
- Helically formed fittings for tension and suspension points
- Earth connections
- Tower down-lead accessories
- Vibration dampers
Helically formed fittings form the major part of accessories for optical fibre aerial cables. They are composed of helically formed rods which according to the respective application - are separate or preassembled, straight or bended on delivery.
Helically formed accessories can be used to tension, to suspend or to connect conductors, optical fibre aerial cables, glass fibre rods and
solid rods such as guys. In addition, helically formed accessories are used for protection or repair of conductors or optical fibre aerial cables,
for attachment to post insulators and for tensioning of street lighting. Helically formed accessories have been used very succesfully since
1950. The application of helically formed accessories is not at all limited to overhead lines. Helically formed accessories are also used to a
large extent for the construction of antennae, radar stations etc.
The principle of operation of helically formed accessories is based on the principle of the development of a low pressure over a large area.
The inside diameter of the unloaded helical rods is slightly smaller than the outside diameter of the conductor, optical fibre aerial cable or
solid rod. By wrapping the helical rods on a conductor or optical fibre aerial cable, a spring tension is created, producing the necessary
frictional contact. This spring tension is elastic and ensures a constant grip.
To ensure the full performance, helically formed accessories must exactly be adapted to the outside diameter of conductor, optical fibre
aerial cable or solid rod.
In general, helically formed accessories are made of a material similar to that of conductor, optical fibre aerial cable or solid rod. Usually this
garanties a similar corrosion resitivity.
Installation of helically formed accessories can be done without any tools. Installation faults are nearly impossible. Mounting instructions are
available on demand. Helically formed accessories are largely protected by patents or registration of designs. If helically formed accessories
are required for applications other than those included in this catalogue, a specific inquiry is requested.
The RIBE numbers of helically formed accessories start with a combination of letters that is followed by six figures and possibly letters added
at the end.
for example: AG 089 077
The respective letters or figures have the following meaning:
1) Starting letters
The first capital letter and in some cases the first and the second letter designate the respective type.
A - Dead ends
B - Spacers
D - Vibration dampers
J - Insulator ties

Stand: 19. Juni 2006


Pfad: Optofit/General/ Introduction/
Gedruckt am: 08. Januar 2010

1 / 117

ONLINE-CATALOGUE
L - Line guards
LT - Suspension grips
M - Bird flight diverters (star)
R, UR, UT - Protection rods
S - Armor rods
T - Suspension rods
V - Line splices
Z - Bird flight diverters (spring)
The last capital letter and in some cases also the before last designate the material.
A - Aluminium alloy
B - Bronze
G - Steel, h.d.g.
H - Stainless steel
K - Copper alloy
P - Plastic material
S - Other material combinations
V - Copper-clad steel
W - Aluminium-clad steel
2) Six figures
The six figures of the RIBE number shall be considered as two groups, three figures each. The first group gives by pointing off the last figure
the largest possible cable diameter for which the accessory is suitable (measurement: mm). The second group indicates the overall length of
accessory in cm.
3) Letters added to the RIBE number
The letters added to the RIBE number refer to special applications or the nature of the accessory. The respective letters have the following
meaning:
H - Suitable for post insulator with neck
L - Suitable for "Lngsbund" type insulator
M - Suitable for "Mittelbund" type insulator
li - Left hand outer lay accessory
s - Special design

Stand: 19. Juni 2006


Pfad: Optofit/General/ Introduction/
Gedruckt am: 08. Januar 2010

2 / 117

ONLINE-CATALOGUE
B8/9 Suspension arrangement

Suspension arrangement for OPGW (schematic representation)

1 ..... OPGW
2 ..... Tower
3 ..... C-shaped support
4 ..... Armour grip suspension
5 ..... Vibration damper
6 ..... Shunt (optional)
Suspension arrangement for thin ADSS cable (schematic representation)

1 ..... ADSS cable


2 ..... Shackle
3 ..... Armour grip suspension
4 ..... Vibration damper

Stand: 26. Juni 2006


Pfad: Optofit/General/ Suspension arrangement/
Gedruckt am: 08. Januar 2010

3 / 117

ONLINE-CATALOGUE
B8/10 Tension arrangement

Tension arrangement with OPGW passing the tower (schematic representation)

1 ...... OPGW
2 ...... Tower
3 ...... Tension support
4 ...... Pair of straps
5 ...... Twisted double eye
6 ...... Thimble
7 ...... Helical dead end
8 ...... Protection rods
9 ...... Vibration damper
10 .... Parallel groove clamp
11 .... Shunt
Tension arrangement with ADSS cable passing the tower (schematic representation)

1 ..... ADSS cable


2 ..... Wooden pole
3 ..... Hook
4 ..... Helical dead end
Tension arrangement with OPGW at the tower with joint box (schematic representation)

Stand: 17. Mai 2006


Pfad: Optofit/General/ Tension arrangement/
Gedruckt am: 08. Januar 2010

4 / 117

ONLINE-CATALOGUE

1 ...... OPGW
2 ...... Tower
3 ...... Tension support
4 ...... Pair of straps
5 ...... Twisted double eye
6 ...... Thimble
7 ...... Helical dead end
8 ...... Protection rods
9 ...... Vibration damper
10 .... Parallel groove clamp
11 .... Shunt
12 .... Fixing clamp
13 .... Filler bolt
Tension arrangement with ADSS cable at the tower with joint box (schematic representation)

Stand: 17. Mai 2006


Pfad: Optofit/General/ Tension arrangement/
Gedruckt am: 08. Januar 2010

5 / 117

ONLINE-CATALOGUE
1 ..... ADSS cable
2 ..... Tower
3 ..... Hook
4 ..... Thimble
5 ..... Helical dead end

Stand: 17. Mai 2006


Pfad: Optofit/General/ Tension arrangement/
Gedruckt am: 08. Januar 2010

6 / 117

ONLINE-CATALOGUE
B8/11 String accessories for tower attachment of self supporting optical fibre aerial
cables

Variant A of tower attachment

Variant B of tower attachment

Variant C of tower attachment

Stand: 17. Mai 2006


Pfad: Optofit/General/ String accessories for tower attachment of self supporting optical fibre aerial cables/
Gedruckt am: 08. Januar 2010

7 / 117

ONLINE-CATALOGUE
1 ...... Vertical tension hinge
2 ...... Turnbuckle (eye - eye)
3 ...... Turnbuckle (clevis - eye)
4 ...... Straight clevis eye
5 ...... Adjustable clevis eye
6 ...... Twisted double eye
7 ...... Twisted clevis eye
8 ...... Straight clevis eye
9 ...... Pair of straps
10 .... Horizontal U-bolt
11 .... Shackle
12 .... Horizontal tension hinge
13 .... Tower
14 .... Tension support
15 .... Protection rods
16 .... Thimble
17 .... Dead end
Remark:
Detail informations of string accessories contain the RIBE-catalogue "Insulator string hardware".

Stand: 17. Mai 2006


Pfad: Optofit/General/ String accessories for tower attachment of self supporting optical fibre aerial cables/
Gedruckt am: 08. Januar 2010

8 / 117

ONLINE-CATALOGUE
B800/0 Introduction to armour grip suspensions

Design and performance:


The armour grip suspension is used for the movable suspension of conductors and optical fibre aerial cables on suspension towers.
The armour grip suspension is composed of a certain number of helically formed rods, a concave Neoprene insert consisting of two halfs and
a clamp body. The helical rods are placed on the Neoprene insert at the suspension point. This centre assembly is fixed by the clamp body
which due to positive locking prevents axial displacement of the conductor.
The armour grip suspension - like the application of suspension clamps along with armour rods - does not impede asymmetric vibration and
thus avoids local alternating bending stress. This is no static compression force existing in standard suspension clamps with and without
armour rods due to the keeper with bolts. This is the principle difference of the armour grip suspension compared to suspension equipments
commonly used up to now. The reinforcement of the cross-section by armor rods improves the lifetime of the vibrating conductor/ optical fibre
aerial cable. However, it is no damping device to cope with conductor vibrations.
The electrical connection of the helical rods and the suspension equipment is resistant to short-circuit current, i.e. it is capable to conduct the
short circuit current of a conductor/ optical fibre aerial cable without damage.
Material:
Helical rods and clamp bodies are made of high-tensile, corrosion-resistant aluminium alloy, inserts of Neoprene, straps and threaded bolts
of hot-dip galvanized steel.
Installation:
The Neoprene composed of two concave halves is placed on the conductor/ optical fibre aerial cable at the suspension point and attached
by the helical rods which are wrapped on the conductor/ optical fibre aerial cable with insert. The clamp body of the suspension equipment is
placed on either side of the centre assembly thus that is embraced by the clamp body. The clamp body is attached by application of a bolt.
Apart from a tubular hexagon box spanner, no special tooling is required for assembly. The assembly has to be performed in accordance
with RIBE-Mounting Instruction No. 10.

Stand: 10. August 2006


Pfad: Optofit/ Suspension fittings/ Introduction to armour grip suspensions/
Gedruckt am: 08. Januar 2010

9 / 117

ONLINE-CATALOGUE
B801/1 Armour grip suspensions for self supporting optical fible aerial cables (without
shunt attachment)

1 ..... Clamp body with neoprene-insert


2 ..... Helical rods
3 ..... Fig. 1
4 ..... Fig. 2
5 ..... Bolt 1
RIBE-Order-No.

Clamping range

(1+2)
LTA 097 180/17
LTA 104 180/5
LTA 111 180/6
LTA 118 180/9
LTA 125 180/10
LTA 131 180/11
LTA 137 180/12
LTA 144 180
LTA 149 180
LTA 157 180
LTA 161 200
LTA 165 200
LTA 172 200
LTA 179 200
LTA 186 200
LTA 193 200
LTA 203 200
LTA 213 200
LTA 222 200
LTA 231 220
LTA 237 220
LTA 243 220
LTA 249 240
LTA 256 240
LTA 265 240
LTA 274 250
LTA 283 250
LTA 292 250
LTA 299 300
LTA 306 300
LTA 311 300
LTA 317 300

mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 - 17,2
17,3 - 17,9
18,0 - 18,6
18,7 - 19,3
19,4 - 20,3
20,4 - 21,3
21,4 - 22,2
22,3 - 23,1
23,2 - 23,7
23,8 - 24,3
24,4 - 24,9
25,0 - 25,6
25,7 - 26,5
26,6 - 27,4
27,5 - 28,3
28,4 - 29,2
29,3 - 29,9
30,0 - 30,6
30,70 -31,14
31,15 -31,74

RIBE-No.
Clamp+NeopreneInsert (1)
B 801 006
(Fig. 1)

F 13 108
(Fig. 1)

F 2787
(Fig. 2)

F 2698
(Fig. 2)

F 2789
(Fig. 2)

F 2730
(Fig. 2)

F 2792
(Fig. 2)

Ribe-No.
KA 097 180 s
KA 104 180 s
KA 111 180 s
KA 118 180 s
KA 125 180 s
KA 131 180 s
KA 137 180 s
KA 144 180 s
KA 149 180 s
KA 157 180 s
KA 161 200 s
KA 165 200 s
KA 172 200 s
KA 179 200 s
KA 186 200 s
KA 193 200 s
KA 203 200 s
KA 213 200 s
KA 222 200 s
KA 231 220 s
KA 237 220 s
KA 243 220 s
KA 249 240 s
KA 256 240 s
KA 265 240 s
KA 274 250 s
KA 283 250 s
KA 292 250 s
KA 299 300 s
KA 306 300 s
KA 311 300 s
KA 317 300 s

Helical rods
L

mm mm

1800 4,24

1800
1800
1800 4,62
2000
2000
2000 5,18

2000
2000 6,35
2000
2200
2200
2200 6,35
2400
2400
2400
2500
2500 7,87
2500
3000
3000

No. of rods
mm mm
8
9
10
10
10
11
11
11
11
11
12
12
11
12
12
12
11
11
12
12
12
13
13
13
11
11
12
12
12
12
11
11

Stand: 06. November 2008


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment)/
Gedruckt am: 08. Januar 2010

76

82

89

84

96 105

115 115

127 136

140 145

Bolt 1
Mass/ Ith
Size
s
pcs
mm kg kA
1,8
1,8
1,8
M 8x35 13
1,9 16
1,9
2,0
2,0
2,4
2,4
M 8x35 13
2,5 22
2,6
2,6
3,4
M 10x42 17
3,5 27
3,5
3,5
4,6
M 10x45 17
4,6 28
4,7
5,0
5,9
M 12x55 19
6,1 27
6,3
6,3
8,6
8,7
M 12x55 19
9,1 40
9,2
9,9
10,0

10 / 117

FN
kN

40

90

90

90

85

150

ONLINE-CATALOGUE
RIBE-Order-No.

Clamping range

(1+2)
LTA 326 300
LTA 333 300
LTA 344 300
s - Width across flats

mm
31,75 -32,66
32,67 -33,37
33,38 -34,43

RIBE-No.
Clamp+NeopreneInsert (1)

Helical rods
L

mm mm
KA 326 300 s 3000 9,27
KA 333 300 s
KA 344 300 s
Ribe-No.

Bolt 1
Mass/ Ith FN
Size
s
pcs
mm mm
mm kg kA kN
150 200 M 12x55 19 13,0 40 150
a

No. of rods
12
12
12

Material:
Helical rods: Aluminium alloy
Clamp body: Aluminium alloy
Straps: Steel, h.d.g.
Bolt: Steel, h.d.g.
Insert: Neoprene
Application:
See data-sheet B800
Remarks:
For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay
direction on request (order example: LTA 172 200 lis).
For other executions please inquire.

Stand: 06. November 2008


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment)/
Gedruckt am: 08. Januar 2010

11 / 117

ONLINE-CATALOGUE
B801/2 Armour grip suspensions for self supporting optical fible aerial cables (with shunt
attachment)

1 ..... Clamp body with neoprene-insert


2 ..... Helical rods
3 ..... Fig. 1
4 ..... Fig. 2
5 ..... Attachment for shunts
6 ..... Bolt 1
RIBE-Order-No.

Clamping range

(1+2)
LTA 097 180/18
LTA 104 180/7
LTA 111 180/8
LTA 118 180/12
LTA 125 180/14
LTA 131 180/15
LTA 137 180/16
LTA 144 180/6
LTA 149 180/7
LTA 157 180/8
LTA 161 200/9
LTA 165 200/10
LTA 172 200/5
LTA 179 200/6
LTA 186 200/7
LTA 193 200/8
LTA 203 200/5+9
LTA 213 200/6+10
LTA 222 200/7+11
LTA 231 220/8+12
LTA 237 220/5+9
LTA 243 220/6+10
LTA 249 240/7+11
LTA 256 240/8+12
LTA 265 240/7+13
LTA 274 250/8+14
LTA 283 250/9+15
LTA 292 250/10+16
LTA 299 300/11+17
LTA 306 300/12+18
LTA 311 300/6+11

mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 - 17,2
17,3 - 17,9
18,0 - 18,6
18,7 - 19,3
19,4 - 20,3
20,4 - 21,3
21,4 - 22,2
22,3 - 23,1
23,2 - 23,7
23,8 - 24,3
24,4 - 24,9
25,0 - 25,6
25,7 - 26,5
26,6 - 27,4
27,5 - 28,3
28,4 - 29,2
29,3 - 29,9
30,0 - 30,6
30,70 -31,14

RIBE-No.
Clamp+NeopreneInsert (1)
B 801 006
(Fig. 1)

F 13 108
(Fig. 1)

F 2787
(Fig. 2)

F 2698
(Fig. 2)

F 2789
(Fig. 2)

F 2730
(Fig. 2)

F 2792

Helical rods
Ribe-No.
L
No. of rods
mm mm
KA 097 180 s
8
KA 104 180 s
9
KA 111 180 s
10
KA 118 180 s 1800 4,24
10
KA 125 180 s
10
KA 131 180 s
11
KA 137 180 s
11
KA 144 180 s 1800
11
KA 149 180 s 1800
11
KA 157 180 s 1800 4,62
11
KA 161 200 s 2000
12
KA 165 200 s 2000
12
KA 172 200 s
11
KA 179 200 s 2000 5,18
12
KA 186 200 s
12
KA 193 200 s
12
KA 203 200 s 2000
11
KA 213 200 s 2000 6,35
11
KA 222 200 s 2000
12
KA 231 220 s 2200
12
KA 237 220 s 2200
12
KA 243 220 s 2200 6,35
13
KA 249 240 s 2400
13
KA 256 240 s 2400
13
KA 265 240 s 2400
11
KA 274 250 s 2500
11
KA 283 250 s 2500 7,87
12
KA 292 250 s 2500
12
KA 299 300 s 3000
12
KA 306 300 s 3000
12
KA 311 300 s
11

Stand: 06. November 2008


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment)/
Gedruckt am: 08. Januar 2010

mm mm

76

13

1,8

16 40

13

2,1
2,1
2,2
2,4
2,4

22 90

96 105 M 10x42 17

3,1

27 90

89

82

Bolt 1
Mass/ Ith FN
Size
s
pcs
mm kg kA kN

84

M 8x35

M 8x35

115 115 M 10x45 17

127 136 M 12x55 19

140 145 M 12x55 19

4,2
4,2
4,4
4,4
5,7

8,7
8,7
9,1
9,1
9,1
9,1

28 90

27 85

40 150

12 / 117

ONLINE-CATALOGUE
RIBE-Order-No.

Clamping range

(1+2)
LTA 317 300/7+12
LTA 326 300/8+13
LTA 333 300/9+14
LTA 344 300/10+15
s - Width across flats

mm
31,15 -31,74
31,75 -32,66
32,67 -33,37
33,38 -34,43

RIBE-No.
Clamp+NeopreneInsert (1)
(Fig. 2)

Helical rods
a b
Bolt 1
Mass/ Ith FN
L
No. of rods
Size
s
pcs
mm mm
mm mm
mm kg kA kN
KA 317 300 s
11
KA 326 300 s 3000 9,27
12
150 200 M 12x55 19 13,0 40 150
KA 333 300 s
12
KA 344 300 s
12
Ribe-No.

Material:
Helical rods: Aluminium alloy
Clamp body: Aluminium alloy
Straps: Steel, h.d.g.
Bolt: Steel, h.d.g.
Insert: Neoprene
Application:
See data-sheet B800
Remarks:
For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay
direction on request (order example: LTA 172 200/5 lis).
Armour grip suspensions and shunts have to be ordered separately (shunts: see data-sheet B834/1 and B834/2).
For other executions please inquire.

Stand: 06. November 2008


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment)/
Gedruckt am: 08. Januar 2010

13 / 117

ONLINE-CATALOGUE
B801/3 Armour grip suspensions for self supporting optical fible aerial cables (without
shunt attachment, short version)

1 ..... Clamp body with neoprene-insert


2 ..... Helical rods
3 ..... Fig. 1
4 ..... Fig. 2
5 ..... Bolt 1
RIBE-Order-No.

Clamping range

(1+2)
LTA 097 130/17
LTA 104 130/5
LTA 111 130/6
LTA 118 130/9
LTA 125 130/10
LTA 131 130/11
LTA 137 130/12
LTA 144 132
LTA 149 132
LTA 157 132
LTA 161 142
LTA 165 142
LTA 172 152
LTA 179 152
LTA 186 152
LTA 193 152
LTA 203 162
LTA 213 162
LTA 222 168
LTA 231 168
LTA 237 193
LTA 243 193
LTA 249 193
LTA 256 193
LTA 265 213
LTA 274 213
LTA 283 213
LTA 292 213
LTA 299 213
LTA 306 213
LTA 311 224
LTA 317 224

mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 - 17,2
17,3 - 17,9
18,0 - 18,6
18,7 - 19,3
19,4 - 20,3
20,4 - 21,3
21,4 - 22,2
22,3 - 23,1
23,2 - 23,7
23,8 - 24,3
24,4 - 24,9
25,0 - 25,6
25,7 - 26,5
26,6 - 27,4
27,5 - 28,3
28,4 - 29,2
29,3 - 29,9
30,0 - 30,6
30,70 -31,14
31,15 -31,74

RIBE-No.
Clamp+NeopreneInsert (1)
B 801 006
(Fig. 1)

F 13 108
(Fig. 1)

F 2787
(Fig. 2)

F 2698
(Fig. 2)

F 2789
(Fig. 2)

F 2730
(Fig. 2)

F 2792
(Fig. 2)

Ribe-No.
KA 097 127
KA 104 130
KA 111 130
KA 118 130
KA 125 130
KA 131 130
KA 137 130
KA 144 132
KA 149 132
KA 157 132
KA 161 142
KA 165 142
KA 172 152
KA 179 152
KA 186 152
KA 193 152
KA 203 162
KA 213 162
KA 222 168
KA 231 168
KA 237 193
KA 243 193
KA 249 193
KA 256 193
KA 265 213
KA 274 213
KA 283 213
KA 292 213
KA 299 213
KA 306 213
KA 311 224
KA 317 224

Helical rods
L

No. of rods
mm mm
1270
8
1300
9
1300
10
1300 4,24
10
1300
10
1300
11
1300
11
1320
11
1320
11
1320 4,62
11
1420
12
1420
12
11
1520 5,18
12
12
12
1620
11
1620 6,35
11
1680
12
1680
12
12
1930 6,35
13
13
13
11
11
2130 7,87
12
12
12
12
11
11

mm mm

76

13

1,8

16 40

M 8x35

13

2,1
2,1
2,2
2,4
2,4

22 90

96 105 M 10x42

17

3,1

27 90

115 115 M 10x45

17

127 136 M 12x55

19

89

82

Bolt 1
Mass/ Ith FN
Size
s
pcs
mm kg kA kN

84

M 8x35

140 145 M 12x55

Stand: 25. Juli 2007


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment, short version)/
Gedruckt am: 08. Januar 2010

19

4,2
4,2
4,4
4,4
5,7

8,7
8,7
9,1
9,1
9,1
9,1
11,2
11,2

28 90

27 85

40 150

14 / 117

ONLINE-CATALOGUE
RIBE-Order-No.

Clamping range

(1+2)
LTA 326 224
LTA 333 224
LTA 344 224
s - Width across flats

mm
31,75 -32,66
32,67 -33,37
33,38 -34,43

RIBE-No.
Clamp+NeopreneInsert (1)

Helical rods
L

No. of rods
mm mm
KA 326 224 2240 9,27
12
KA 333 224
12
KA 344 224
12
Ribe-No.

Bolt 1
Mass/ Ith FN
Size
s
pcs
mm mm
mm kg kA kN
150 200 M 12x55 19 11,7 40 150
11,7
11,7
a

Material:
Helical rods: Alumnium alloy
Clamp body: Aluminium alloy
Straps: Steel, h.d.g.
Bolt: Steel, h.d.g.
Insert: Neoprene
Application:
See data-sheet B800
Remarks:
For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay
direction on request (order example: LTA 118 13/9 li).
For other executions please inquire.

Stand: 25. Juli 2007


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (without shunt attachment, short version)/
Gedruckt am: 08. Januar 2010

15 / 117

ONLINE-CATALOGUE
B801/4 Armour grip suspensions for self supporting optical fible aerial cables (with shunt
attachment, short version)

1 ..... Clamp body with neoprene-insert


2 ..... Helical rods
3 ..... Fig. 1
4 ..... Fig. 2
5 ..... Attachment for shunts
6 ..... Bolt 1
RIBE-Order-No.

Clamping range

(1+2)
LTA 097 130/18
LTA 104 130/7
LTA 111 130/8
LTA 118 130/13
LTA 125 130/14
LTA 131 130/15
LTA 137 130/16
LTA 144 132/6
LTA 149 132/7
LTA 157 132/8
LTA 161 142/9
LTA 165 142/10
LTA 172 152/5
LTA 179 152/6
LTA 186 152/7
LTA 193 152/8
LTA 203 162/5
LTA 213 162/6
LTA 222 168/7
LTA 231 168/8
LTA 237 193/5+9
LTA 243 193/6+10
LTA 249 193/7+11
LTA 256 193/8+12
LTA 265 213/7+13
LTA 274 213/8+14
LTA 283 213/9+15
LTA 292 213/10+16
LTA 299 213/11+17
LTA 306 213/12+18
LTA 311 224/6+11

mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 - 17,2
17,3 - 17,9
18,0 - 18,6
18,7 - 19,3
19,4 - 20,3
20,4 - 21,3
21,4 - 22,2
22,3 - 23,1
23,2 - 23,7
23,8 - 24,3
24,4 - 24,9
25,0 - 25,6
25,7 - 26,5
26,6 - 27,4
27,5 - 28,3
28,4 - 29,2
29,3 - 29,9
30,0 - 30,6
30,70 -31,14

RIBE-No.
Clamp+NeopreneInsert (1)
B 801 006
(Fig. 1)

F 13 108
(Fig. 1)

F 2787
(Fig. 2)

F 2698
(Fig. 2)

F 2789
(Fig. 2)

F 2730
(Fig. 2)

F 2792

Ribe-No.
KA 097 127
KA 104 130
KA 111 130
KA 118 130
KA 125 130
KA 131 130
KA 137 130
KA 144 132
KA 149 132
KA 157 132
KA 161 142
KA 165 142
KA 172 152
KA 179 152
KA 186 152
KA 193 152
KA 203 162
KA 213 162
KA 222 168
KA 231 168
KA 237 193
KA 243 193
KA 249 193
KA 256 193
KA 265 213
KA 274 213
KA 283 213
KA 292 213
KA 299 213
KA 306 213
KA 311 224

Helical rods
L
No. of rods
mm mm
8
9
10
1800 4,24
10
10
11
11
1320
11
1320
11
1320 4,62
11
1420
12
1420
12
11
2000 5,18
12
12
12
1620
11
1620 6,35
11
1680
12
1680
12
1930
12
1930 6,35
13
1930
13
1930
13
11
11
2130 7,87
12
12
12
12
11

mm mm

76

13

1,8

16 40

M 8x35

13

2,1
2,1
2,2
2,4
2,4

22 90

96 105 M 10x42

17

3,1

27 90

115 115 M 10x45

17

127 136 M 12x55

19

89

82

Bolt 1
Mass/ Ith FN
Size
s
pcs
mm kg kA kN

84

M 8x35

140 145 M 12x55

Stand: 25. Juli 2007


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment, short version)/
Gedruckt am: 08. Januar 2010

19

4,2
4,2
4,4
4,4
5,7

8,7
8,7
9,1
9,1
9,1
9,1
11,2

28 90

27 85

40 150

16 / 117

ONLINE-CATALOGUE
RIBE-Order-No.

Clamping range

(1+2)
LTA 317 224/7+12
LTA 326 224/8+13
LTA 333 224/9+14
LTA 344 224/10+15
s - Width across flats

mm
31,15 -31,74
31,75 -32,66
32,67 -33,37
33,38 -34,43

RIBE-No.
Clamp+NeopreneInsert (1)
(Fig. 2)

Ribe-No.
KA 317 224
KA 326 224
KA 333 224
KA 344 224

Helical rods
a
b
Bolt 1
L
No. of rods
Size
s
mm mm
mm mm
mm
11
2240 9,27
12
150 200 M 12x55 19
12
12

Mass/ Ith FN
pcs
kg kA kN
11,2
11,7 40 150
11,7
11,7

Material:
Helical rods: Alumnium alloy
Clamp body: Aluminium alloy
Straps: Steel, h.d.g.
Bolt: Steel, h.d.g.
Insert: Neoprene
Application:
See data-sheet B800
Remarks:
For installation follow RIBE-Mounting Instruction No. 10. All mentioned armour grip suspensions are available with left-hand lay
direction on request (order example: LTA 118 130/16 li).
Armour grip suspensions and shunts have to be ordered separately (shunts: see data-sheet B834/1 and B834/2).
For other executions please inquire.

Stand: 25. Juli 2007


Pfad: Optofit/ Suspension fittings/ Armour grip suspensions for self supporting optical fible aerial cables (with shunt attachment, short version)/
Gedruckt am: 08. Januar 2010

17 / 117

ONLINE-CATALOGUE
B803/1 C-shaped supports for armour grip suspensions

F1 ..... Horizontal tensile force


F2 ..... Vertical tensile force
F3 ..... Horizontal tensile force rectangular to the line direction
RIBE-Order-No.
d2

F1

Minimum Failure Load*


F2

F3

mm
mm
F 13 818/1
13,5
20
F 13 818/2
15,0
20
18,0
20
F 13 818/3
F 13 818/4
20,5
20
F 13 818/5
13,5
24
F 13 818/6
15,0
24
F 13 818/7
18,0
24
F 13 818/8
20,5
24
F 13 818/9
24,0
20
* Specified Minimum Failure Loads for bolts and nuts 8.8 h.d.g.

kN

kN

kN

40

40

40

11,4

d1

Mass/pcs

Material:
Support: Cast steel, h.d.g.
Pivotal joints: Cast steel, h.d.g.
Pin: Stainless steel
Application:
C-shaped supports are preferably used on the top of suspension towers to suspend ground wires and optical fibre aerial cables.
The attachment of the suspension clamp is made by a cardanic joint which assures universal movement of the suspension fitting. The
mechanical behaviour of the suspension is almost identical to that of the conductor suspension in suspension sets.
The C-shaped support is resistant to short-circuit. Additionally articulation points can be thermically relieved by using shunts.
C-shaped supports can also be installed with insulation. For that the insulation set RIBE-No. 115 250 is required.
The connection for suspension clamps correponds to LA/ LB 19 or 22 to DIN 48 074, i.e. all customary suspension clamps with strap
widths according to GA/ GB 19 or 22 can be inserted without changing of straps.

Stand: 26. Juni 2006


Pfad: Optofit/ Suspension fittings/ C-shaped supports for armour grip suspensions/
Gedruckt am: 08. Januar 2010

18 / 117

ONLINE-CATALOGUE
Because of its C-shape, the support permits the suspension clamp to pivot up to 45.

Fig.: Mounting example C-shaped support and armour grip suspension

Remarks:
Bolts for tower connection of the support are included only upon special request with indication of required bolt dimension.
Armour grip suspensions and C-shaped supports have to be ordered separately (armour grip suspensions for C-shaped support: see
data-sheet B801 ff.)
For other executions please inquire.

Stand: 26. Juni 2006


Pfad: Optofit/ Suspension fittings/ C-shaped supports for armour grip suspensions/
Gedruckt am: 08. Januar 2010

19 / 117

ONLINE-CATALOGUE
B804/1 Suspension supports without shunt attachment

RIBE-Order-No.
F 13 820/3
F 13 820/5
F 13 820/1
F 13 820/7
F 13 820/9
F 13 820/11
B 804 014/1
B 804 014/2
B 804 014/3
B 804 014/4
B 804 014/5

Clamping range
mm
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5

Helical rods
KA 104 180s
KA 111 180s
KA 118 180s
KA 125 180s
KA 131 180s
KA 137 180s
KA 144 180s
KA 149 180s
KA 157 180s
KA 161 200s
KA 165 200s

Material:
Support: Steel, h.d.g.
Helical rods: Aluminium alloy
Application:
Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and
optical fibre aerial cables.
The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts.
Suspension supports can also be installed with insulation. For that the insulation set RIBE-No. 115 250 is required.
Remark:
Bolts for tower connection of the support are included only upon request with indication of required bolt dimension.

Stand: 16. Mai 2006


Pfad: Optofit/ Suspension fittings/ Suspension supports without shunt attachment/
Gedruckt am: 08. Januar 2010

20 / 117

ONLINE-CATALOGUE
B804/2 Suspension supports with shunt attachment

RIBE-Order-No.
F 13 820/4
F 13 820/6
F 13 820/2
F 13 820/8
F 13 820/10
F 13 820/12
B 804 014/6
B 804 014/7
B 804 014/8
B 804 014/9
B 804 014/10

Clamping range
mm
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5

Helical rods

Shunt

KA 104 180s
KA 111 180s
KA 118 180s
KA 125 180s
KA 131 180s
KA 137 180s
KA 144 180s
KA 149 180s
KA 157 180s
KA 161 200s
KA 165 200s

F 13 820-04 (Cu 35 mm)


F 13 820-04 (Cu 35 mm)
F 13 820-04 (Cu 35 mm)
F 13 820-04 (Cu 35 mm)
F 13 820-04 (Cu 35 mm)
F 13 820-04 (Cu 35 mm)
F 13 815-03 (Cu 35 mm)
F 13 815-03 (Cu 35 mm)
F 13 815-03 (Cu 35 mm)
F 13 815-03 (Cu 35 mm)
F 13 815-03 (Cu 35 mm)

Material:
Support: Steel, h.d.g.
Helical rods: Aluminium alloy
Shunt: Copper
Application:
Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and
optical fibre aerial cables.
The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts.
Suspension supports can also be installed with insulation. For that the insulation set RIBE-No. 115 250 is required.
Remarks:
Bolts for tower connection of the support are included only upon request with indication of required bolt dimension.
Suspension supports and shunts have to be ordered separately.

Stand: 16. Mai 2006


Pfad: Optofit/ Suspension fittings/ Suspension supports with shunt attachment/
Gedruckt am: 08. Januar 2010

21 / 117

ONLINE-CATALOGUE
B804/4 Suspension supports without shunt attachment (special design)

1 ..... Bolts
RIBE-Order-No.
B 804 018/14
B 804 018/7
B 804 018/8
B 804 018/9
B 804 018/10
B 804 018/11
B 804 018/12
B 804 017/6
B 804 017/7
B 804 017/8
B 804 017/9
B 804 017/10
B 804 019/5
B 804 019/6
B 804 019/7
B 804 019/8

Clamping range
mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 17,2
17,3 17,9
18,0 18,6
18,7 19,3

Helical rods

Bolts

KA 097 180 lis


KA 104 180 lis
KA 111 180 lis
KA 118 180 lis
KA 125 180 lis
KA 131 180 lis
KA 137 180 lis
KA 144 180 lis
KA 149 180 lis
KA 157 180 lis
KA 161 200 lis
KA 165 200 lis
KA 172 200 lis
KA 179 200 lis
KA 186 200 lis
KA 193 200 lis

M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16

Material:
Support: Steel, h.d.g.
Helical rods: Alumimium alloy
Application:
Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and
optical fibre aerial cables.
The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts.
Remark:
Bolts for tower connection of the support are included only upon request with indication of required bolt dimension.

Stand: 03. Mai 2007


Pfad: Optofit/ Suspension fittings/ Suspension supports without shunt attachment (special design)/
Gedruckt am: 08. Januar 2010

22 / 117

ONLINE-CATALOGUE
B804/5 Suspension supports with shunt attachment (special design)

1 ..... Bolts
RIBE-Order-No.
B 804 018/13
B 804 018/1
B 804 018/2
B 804 018/3
B 804 018/4
B 804 018/5
B 804 018/6
B 804 017/1
B 804 017/2
B 804 017/3
B 804 017/4
B 804 017/5
B 804 019/1
B 804 019/2
B 804 019/3
B 804 019/4

Clamping range
mm
9,0 - 9,7
9,8 - 10,4
10,5 - 11,1
11,2 - 11,8
11,9 - 12,5
12,6 - 13,1
13,2 - 13,7
13,8 - 14,4
14,5 - 14,9
15,0 - 15,7
15,8 - 16,1
16,2 - 16,5
16,6 17,2
17,3 17,9
18,0 18,6
18,7 19,3

Helical rods

Bolts

Shunt

KA 097 180 lis


KA 104 180 lis
KA 111 180 lis
KA 118 180 lis
KA 125 180 lis
KA 131 180 lis
KA 137 180 lis
KA 144 180 lis
KA 149 180 lis
KA 157 180 lis
KA 161 200 lis
KA 165 200 lis
KA 172 200 lis
KA 179 200 lis
KA 186 200 lis
KA 193 200 lis

M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16

60 500
60 500
60 500
60 500
60 500
60 500
60 500
60 501
60 501
60 501
60 501
60 501
60 502
60 502
60 502
60 502

Material:
Support: Steel, h.d.g.
Helical rods: Aluminium rods
Shunt: Copper
Application:
Suspension supports are preferably installed on the top of suspension towers and are used for the suspension of ground wires and
optical fibre aerial cables.
The suspension support is resistant to short-circuit. Additionally articulation points can be thermically relieved by shunts.
Remarks:
Bolts for tower connection of the support are included only upon request with indication of required bolt dimension.
Suspension supports and shunts have to be ordered separately.
Shunts: see data-sheet B834/1 and B834/2

Stand: 03. Mai 2007


Pfad: Optofit/ Suspension fittings/ Suspension supports with shunt attachment (special design)/
Gedruckt am: 08. Januar 2010

23 / 117

ONLINE-CATALOGUE
B805/2 Suspension rods for ADSS cable and medium span lengths from 70 - 150 m

1 ..... Suspension rods


2 ..... Thimble
3 ..... Protection rods
RIBE-Order-No.
TG 127 096
TG 134 097
TG 143 098
TG 151 099
TG 161 098
TG 170 099
TG 181 123
TG 192 125
TG 203 125
TG 216 127
TG 229 128
TG 243 170
TG 257 173
TG 273 175
TG 289 259
TG 307 262

Clamping range
mm
12,00 - 12,72
12,73 -13,49
13,50 - 14,31
14,32 - 15,18
15,19 - 16,11
16,12 - 17,08
17,09 - 18,12
18,13 - 19,22
19,23 - 20,38
20,39 - 21,61
21,62 - 22,92
22,93 - 24,31
24,32 - 25,77
25,78 - 27,33
27,34 - 28,98
28,99 - 30,73

Dia. of rods
mm
3,02
3,02
3,02
3,02
3,02
3,02
3,51
3,51
3,51
3,51
3,51
3,51
4,04
4,04
4,04
4,04

L
mm
960
970
980
990
990
1000
1240
1250
1260
1270
1280
1700
1730
1750
2600
2620

No. of rods

Thimble

3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4

E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006

Mass/ pcs
kg
0,21
0,22
0,22
0,23
0,23
0,24
0,50
0,51
0,51
0,52
0,53
0,65
0,88
0,90
1,21
1,23

Material:
Helical rods: Steel, h.d.g.
Application:
Suspension rods consisting of TG-suspension and UTA-protection rods are designed for vertical loads up to 5 kN. They are used for span
lengths from 70 - 150 m approximately. The loop of the TG-suspension rods is stabilized and protected against abrasion by a ring type
thimble.

Fig.: Mounting example

1 ..... Protection rods

Stand: 10. August 2006


Pfad: Optofit/ Suspension fittings/Suspension rods for ADSS cable and medium span lengths from 70 - 150 m/
Gedruckt am: 08. Januar 2010

24 / 117

ONLINE-CATALOGUE
2 ..... Hook
3 ..... Suspension rods
Remarks:
Ring type thimbles (see data-sheet B823), UTA-protection rods (see data-sheet B814/2) and TG-suspension rods have to be ordered
separately.
When selecting the suspension rods it must be considered that the total diameter results from the cable diameter plus two times the rod
diameter of protection rods.
Installation instructions see data-sheet Mon69.

Stand: 10. August 2006


Pfad: Optofit/ Suspension fittings/Suspension rods for ADSS cable and medium span lengths from 70 - 150 m/
Gedruckt am: 08. Januar 2010

25 / 117

ONLINE-CATALOGUE
B805/3 Pulley clamps with spiral attachment for ADSS cable, span lengths up to 150 m
and tensile forces up to 2,5 kN

1 ..... Helical rods


2 ..... Suspension pulley
RIBE-Order-No.
F 13 255-20/01
F 13 255-20/02
F 13 255-20/03
F 13 255-20/04
F 13 255-20/05
F 13 255-20/06
F 13 255-20/07
F 13 255-20/08
F 13 255-20/09
F 13 255-20/10
F 13 255-20/11
F 13 255-20/12
F 13 255-20/13
F 13 255-20/14

Clamping range
mm
7,65 - 8,45
8,46 - 9,26
9,27 - 10,27
10,28 - 11,30
11,31 - 12,35
12,36 - 13,41
13,42 - 14,49
14,50 - 15,60
15,61 - 16,71
16,72 - 17,82
17,83 - 18,90
18,94 - 20,24
20,25 - 21,55
21,56 - 22,86

Helical rods
HRG 084 067
HRG 092 090
HRG 102 068
HRG 113 070
HRG 123 102
HRG 134 094
HRG 144 103
HRG 156 105
HRG 167 114
HRG 178 118
HRG 189 122
HRG 202 124
HRG 215 125
HRG 228 127

Dia. of rods
mm
2,54
2,54
2,54
2,54
3,02
3,02
3,02
3,51
3,51
3,51
3,51
3,51
3,51
3,51

L
mm
670
900
680
700
1020
940
1030
1050
1140
1180
1220
1240
1250
1270

No. of rods
8
8
8
10
10
10
10
10
10
10
10
10
10
10

Mass/ pcs
kg
1,19
1,26
1,24
1,26
1,56
1,53
1,58
1,82
1,89
1,93
1,97
2,01
2,05
2,09

Material:
Helical rods: Steel, h.d.g.
Application:
Pulley clamps with spiral attachment are designed for span lengths up to 150 m approximately and tensile forces up to 2,5 kN.

Stand: 18. August 2006


Pfad: Optofit/ Suspension fittings/ Pulley clamps with spiral attachment for ADSS cable, span lengths up to 150 m and tensile forces up to 2,5 kN/
Gedruckt am: 08. Januar 2010

26 / 117

ONLINE-CATALOGUE
B805/5 Suspension rods for ADSS cable and short span lengths up to 70 m

1 ..... Suspension rods


2 ..... Thimble
3 ..... Supporting rods
RIBE-Order-No.

TG 075 091
TG 082 092
TG 088 093
TG 095 095
TG 102 096
TG 108 096
TG 114 097
TG 120 098
TG 126 100
TG 132 100
TG 138 101
TG 144 101
TG 150 101
TG 156 103
TG 162 103
TG 168 122
TG 174 122
TG 180 123
TG 186 123
TG 192 124
TG 198 124
TG 204 125
TG 210 125
TG 216 126
TG 222 127

LG 075 046 s
LG 082 046 s
LG 088 047 s
LG 095 047 s
LG 102 048 s
LG 108 048 s
LG 114 049 s
LG 120 049 s
LG 126 050 s
LG 132 050 s
LG 138 051 s
LG 144 051 s
LG 150 051 s
LG 156 052 s
LG 162 052 s
LG 168 073 s
LG 174 073 s
LG 180 074 s
LG 186 074 s
LG 192 075 s
LG 198 075 s
LG 204 075 s
LG 210 076 s
LG 216 076 s
LG 222 076 s

Clamping range

Dia. of rods

LTG

LLG

mm
6,91 - 7,5
7,51 - 8,2
8,21 - 8,8
8,81 - 9,5
9,51 - 10,2
10,21 - 10,8
10,81 - 11,4
11,41 - 12,0
12,01 - 12,6
12,61 - 13,2
13,21 - 13,8
13,81 - 14,4
14,41 - 15,0
15,01 - 15,6
15,61 - 16,2
16,21 - 16,8
16,81 - 17,4
17,41 - 18,0
18,01 - 18,6
18,61 - 19,2
19,21 - 19,8
19,81 - 20,4
20,41 - 21,0
21,01 - 21,6
21,61 - 22,2

mm
2,18
2,54
2,54
2,54
2,54
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02
3,02

mm
910
920
930
950
960
960
970
980
1000
1000
1010
1010
1010
1030
1030
1220
1220
1230
1230
1240
1240
1250
1250
1260
1270

mm
460
460
470
470
480
480
490
490
500
500
510
510
510
520
520
730
730
740
740
750
750
750
760
760
760

No. of rods
TG
LG
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
3
3
3
3
4
4
3
4
4

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Thimble

E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
E 5119
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006
F 12006

Mass/ pcs
TG
LG
kg
kg
0,10
0,06
0,14
0,08
0,14
0,08
0,14
0,08
0,14
0,08
0,21
0,11
0,21
0,12
0,21
0,12
0,22
0,12
0,22
0,12
0,22
0,12
0,22
0,13
0,22
0,13
0,23
0,13
0,23
0,13
0,36
0,18
0,36
0,18
0,36
0,18
0,37
0,18
0,37
0,19
0,37
0,19
0,38
0,19
0,38
0,19
0,39
0,19
0,39
0,19

Material:
Helical rods: Steel, h.d.g.
Application:
Suspension rods consisting of thimble, LG- and TG-helical rods are designed for vertical loads up to 1kN. They are used for span lengths up
to 70 m approximately. The TG-suspension rods with the preformed loop is the supporting accessory. The shorter and straight LG-supporting
rods are only used for stiffening the area round the suspension point. The loop of the fitting is stabilized and protected against abrasion with
a ring type thimble.

Stand: 18. August 2006


Pfad: Optofit/ Suspension fittings/ Suspension rods for ADSS cable and short span lengths up to 70 m/
Gedruckt am: 08. Januar 2010

27 / 117

ONLINE-CATALOGUE

Fig.: Mountimg example

1 ..... Suspension rods


2 ..... Hook
Remarks:
Ring type thimbles see data-sheet B823. TG-suspension rods and LG-supporting rods have to be ordered separately.
Mounting instruction see data-sheet Mon51.

Stand: 18. August 2006


Pfad: Optofit/ Suspension fittings/ Suspension rods for ADSS cable and short span lengths up to 70 m/
Gedruckt am: 08. Januar 2010

28 / 117

ONLINE-CATALOGUE
B806/1 Suspension pulleys for ADSS

1 ..... ADSS cable


RIBE-Order-No.

F 13 256
F 13 255/1
F 13 255/2

Diameter of ADSS cable


a
mm

b
mm

c
mm

= 12
= 20
= 30

60
154
154

130
180
180

Rated force
FN
kN
5
5
5

Mass / pcs
kg
0,40
0,97
0,97

Material:
Roll: Polyamid
Straps: Steel, h.d.g.
Bolt, nut: h.d.g., alternatively stainless steel
Application:
Suspension pulleys are used for suspension of ADSS cables (preferably at wooden pole or concrete pole - see figure below). The
suspension pulleys benefit from the fact that in case of a tree falling in the span length the ADSS cable is not destroyed. This has no
influence on the communication line.
To avoid high compression forces at the point of contact between cable and suspension pulleys the use of protection rods is
recommended.

Fig.: Mounting example

1 ..... Wooden pole


2 ..... Thimble
3 ..... Hook

Stand: 18. August 2006


Pfad: Optofit/ Suspension fittings/ Suspension pulleys for ADSS/
Gedruckt am: 08. Januar 2010

29 / 117

ONLINE-CATALOGUE
4 ..... Helical dead end
5 ..... Suspension pulley
6 ..... Protection rods
7 ..... ADSS
Remark:
For other executions please inquire.

Stand: 18. August 2006


Pfad: Optofit/ Suspension fittings/ Suspension pulleys for ADSS/
Gedruckt am: 08. Januar 2010

30 / 117

ONLINE-CATALOGUE
B810/0 Introduction to helical dead ends

1 ..... Helical dead end


2 ..... Thimble
3 ..... Black crossing mark
Design and performance:
Helical dead ends are ideally suited for the full tensioning of self supporting optical fibre aerial cables.
Dead ends are composed of five or more preassembled helical rods which are covered with a small-grained sand on the inside to improve
the frictional contact. The loop of the dead end is protected from abrasion by means of a thimble. The deformation of the cable is omitted as
the radial compression is distributed over a large contact area.
Material:
The helical rods are made of a high-tensile, corrosion-resistant aluminium alloy, of high-tensile hot-dip galvanized steel, or Aluminium-clad
steel; thimbles of hot-dip galvanized malleable cast iron and cotter pins or threaded bolts of hot-dip galvanized steel with tensile strength
class 8.8.
Installation:
The legs of the dead end are wrapped on the cable starting at the marked crossing point. Special tooling is not required.
For installation follow RIBE-Mounting Instruction No. 9.

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ Introduction to helical dead ends/
Gedruckt am: 08. Januar 2010

31 / 117

ONLINE-CATALOGUE
B811 AW-Helical dead ends for OPGW, ADSS and ACSR

1 ..... Helical dead end


2 ..... Thimble
3 ..... Black crossing mark
RIBE-Order-No.
AW 058 052
AW 061 053
AW 063 054
AW 068 076 s
AW 071 055
AW 076 058
AW 079 060
AW 082 064
AW 090 074
AW 099 080
AW 100 080
AW 104 083
AW 108 086
AW 112 090
AW 117 119 s
AW 121 096
AW 128 099
AW 133 100
AW 140 102
AW 165 102
AW 165 117 s
AW 172 106
AW 177 125 s
AW 193 111
AW 193 113
AW 188 136 s
AW 214 144
AW 225 152
AW 237 152
AW 252 152
AW 270 176
AW 285 176

Clamping range
mm
5,56 - 5,84
5,85 - 6,11
6,12 - 6,36
6,61 - 6,84
6,85 - 7,12
7,13 - 7,68
7,69 - 7,95
7,91 - 8,23
8,71 - 9,02
9,47 - 9,95
9,65 - 10,00
10,01 - 10,45
10,46 - 10,84
10,85 - 11,23
11,24 - 11,70
11,50 - 12,10
12,11 - 12,80
12,81 - 13,39
13,40 - 14,40
14,50 - 16,50
14,50 - 16,50
15,20 - 17,20
16,51 17,79
17,30 - 19,30
17,30 - 19,30
17,60 - 18,80
19,40 - 21,40
20,50 - 22,50
21,70 - 23,70
23,20 - 25,20
25,00 - 27,00
26,50 - 28,50

Dia. of rods
mm
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,90
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
4,65
3,25
4,65
3,25
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65

Stand: 25. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ AW-Helical dead ends for OPGW, ADSS and ACSR/
Gedruckt am: 08. Januar 2010

L1

L2

mm
520
530
540
760
550
580
600
640
740
800
800
830
860
900
1190
960
990
1000
1020
1020
1170
1068
1260
1110
1136
1340
1440
1520
1496
1520
1760
1760

mm
570
580
590
810
600
630
650
690
790
850
850
880
910
950
1240
1010
1050
1050
1070
1070
1220
1110
1310
1160
1186
1390
1490
1570
1570
1580
1820
1820

No. of
rods
4
4
4
4
4
5
5
5
5
4
5
5
6
5
6
6
6
6
6
6
5
6
6
8
6
6
6
6
7
7
8
8

Thimble
RIBE-No.

F 2684/3

F 2684/3
or
F 2685/3

F 2685/3

F 2686/2

Mass/ piece
kg
0,16
0,16
0,17
0,24
0,17
0,23
0,24
0,25
0,36
0,40
0,50
0,51
0,64
0,70
0,88
0,70
0,71
0,75
0,75
0,74
1,50
0,76
1,92
1,08
1,73
2,04
2,10
2,22
2,66
2,58
3,40
3,50

32 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
AW 306 192
AW 326 199
AW 341 200
AW 350 200
AW 370 224
AW 390 232

Clamping range
mm
28,50 - 30,60
30,60 - 32,60
32,10 - 34,10
33,00 - 35,00
35,00 - 37,00
37,00 - 39,00

Dia. of rods
mm
4,65
4,65
4,65
5,18
5,18
5,18

L1

L2

mm
1920
1990
2000
2000
2240
2320

mm
1990
2060
2070
2070
2300
2400

No. of
rods
8
9
10
9
9
10

Thimble
RIBE-No.

Mass/ piece
kg
3,70
4,35
5,05
5,60
6,18
6,90

Material:
Helical rods: Aluminium-clad steel
Thimble: Malleable cast iron, h.d.g.
Application:
See data-sheet B810
Remarks:
When selecting helical dead ends the total diameter resulting from the cable diameter plus two times the rod diameter of the protection
rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821).
For installation follow RIBE-Mounting Instruction No. 9.
These dead end designs are only suitable for cables or conductors with right-hand lay armoring and ADSS cables. If dead ends for lefthand lay cables or conductors are required this must specifically be stated when placing the order.
Order example: AW 128 099 li
Thimbles: see data-sheet B821

Stand: 25. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ AW-Helical dead ends for OPGW, ADSS and ACSR/
Gedruckt am: 08. Januar 2010

33 / 117

ONLINE-CATALOGUE
B812 RW-Protection rods

RIBE-Order-No.
RW 090 140 lis
RW 090 160 lis
RW 090 240 lis
RW 101 140 lis
RW 101 160 lis
RW 101 180 lis
RW 101 190 lis
RW 101 240 lis
RW 112 150 lis
RW 112 160 lis
RW 112 200 lis
RW 112 220 lis
RW 112 240 lis
RW 117 180 lis
RW 117 210 lis
RW 117 240 lis
RW 117 300 lis
RW 123 100 lis
RW 123 140 lis
RW 123 170 lis
RW 123 180 lis
RW 123 210 lis
RW 123 240 lis
RW 123 300 lis
RW 123 380 lis
RW 134 070 lis
RW 134 110 lis
RW 134 140 lis
RW 134 160 lis
RW 134 180 lis
RW 134 210 lis
RW 134 240 lis
RW 134 300 lis
RW 144 070 lis
RW 144 100 lis
RW 144 120 lis
RW 144 180 lis
RW 144 200 lis
RW 144 260 lis
RW 144 290 lis
RW 144 320 lis
RW 144 490 lis
RW 144 640 lis
RW 148 070 lis
RW 148 200 lis
RW 148 260 lis
RW 148 300 lis

Clamping range
mm
8,0
9,0
8,0
9,0
8,0
9,0
9,1
10,1
9,1
10,1
9,1
10,1
9,1
10,1
9,1
10,1
10,2
11,2
10,2
11,2
10,2
11,2
10,2
11,2
10,2
11,2
11,3
11,75
11,5
11,75
11,5
11,75
11,5
11,75
11,3
12,3
11,3
12,3
11,3
12,3
11,3
12,3
11,3
12,3
11,3
12,3
11,3
12,3
11,3
12,3
12,4
13,4
12,4
13,4
12,4
13,4
12,4
13,4
12,4
13,4
12,4
13,4
12,4
13,4
12,4
13,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,5
14,4
13,8
14,8
13,8
14,8
13,8
14,8
13,8
14,8

Stand: 18. Dezember 2009


Pfad: Optofit/ Fittings for tension towers/ RW-Protection rods/
Gedruckt am: 08. Januar 2010

Dia. of rods
mm
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
3,25
3,25
3,25
3,25
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
2,90
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25

L
mm
1400
1600
2400
1400
1600
1800
1900
2400
1500
1600
2000
2200
2400
1800
2100
2400
3000
1000
1400
1700
1800
2100
2400
3000
3800
700
1100
1400
1600
1800
2100
2400
3000
700
1000
1200
1800
2000
2600
2900
3200
4900
6400
700
2000
2600
3000

No. of rods

Rod subsets

Sanding

11
11
11
12
12
12
12
12
13
13
13
13
13
12
12
12
12
13
13
13
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

4-4-3
4-4-3
4-4-3
4-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
3-3-3-3
4-4-4
4-4-4
4-4-4
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-3-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3
4-4-3-3

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x

x
x
x

Mass/ pcs
kg
0,60
0,68
1,01
0,65
0,74
0,83
0,68
1,11
0,76
0,80
1,00
1,10
1,20
1,34
1,50
1,71
2,23
0,64
0,89
1,08
1,11
1,30
1,50
1,91
2,42
0,48
0,76
0,96
1,08
1,24
1,42
1,62
2,03
0,70
0,86
1,04
1,56
1,73
2,20
2,51
2,77
4,23
5,54
0,60
1,72
2,25
2,58

34 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
RW 165 070 lis
RW 165 100 lis
RW 165 120 lis
RW 165 200 lis
RW 165 260 lis
RW 165 300 lis
RW 165 420 lis
RW 165 500 lis
RW 166 200 lis
RW 166 280 lis
RW 176 120 lis
RW 176 200 lis
RW 176 260 lis
RW 176 280 lis
RW 176 300 lis
RW 193 070 lis
RW 193 100 lis
RW 193 110 lis
RW 193 120 lis
RW 193 150 lis
RW 193 200 lis
RW 193 210 lis
RW 193 220 lis
RW 193 260 lis
RW 193 290 lis
RW 193 300 lis
RW 193 380 lis
RW 193 440 lis
RW 193 460 lis
RW 193 550 lis
RW 214 070 lis
RW 214 110 lis
RW 214 240 lis
RW 214 300 lis
RW 214 330 lis
RW 214 500 lis
Rw 225 070 lis
RW 225 120 lis
RW 225 150 lis
RW 225 250 lis
RW 225 310 lis
RW 225 350 lis
Rw 225 510 lis
RW 237 070 lis
RW 237 100 lis
RW 237 120 lis
RW 237 195 lis
RW 237 250 lis
RW 237 300 lis
RW 237 310 lis
RW 237 330 lis
RW 237 350 lis
RW 237 500 lis
RW 252 070 lis
RW 252 100 lis
RW 252 120 lis
RW 252 250 lis
RW 252 310 lis

Clamping range
mm
14,5
16,5
14,5
16,5
14,5
16,5
14,5
16,5
14,5
16,5
14,5
16,5
14,5
16,5
14,5
16,5
16,0
16,9
16,0
16,9
17,0
17,6
17,0
17,6
17,0
17,6
17,0
17,6
17,0
17,6
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
17,3
19,3
19,4
21,4
19,4
21,4
19,4
21,4
19,4
21,4
19,4
21,4
19,4
21,4
20,5
22,5
20,5
22,5
20,5
22,5
20,5
22,5
20,5
22,5
20,5
22,5
20,5
22,5
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
21,7
23,7
23,8
25,2
23,8
25,2
23,8
25,2
23,8
25,2
23,8
25,2

Stand: 18. Dezember 2009


Pfad: Optofit/ Fittings for tension towers/ RW-Protection rods/
Gedruckt am: 08. Januar 2010

Dia. of rods
mm
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
3,25
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65

L
mm
700
1000
1200
2000
2600
3000
4200
5000
2000
2800
1200
2000
2600
2800
3000
700
1000
1100
1200
1500
2000
2100
2200
2600
2900
3000
3800
4400
4600
5500
700
1100
2400
3000
3300
5000
700
1200
1500
2500
3100
3500
5100
700
1000
1200
1950
2500
3000
3100
3300
3500
5000
700
1000
1200
2500
3100

No. of rods

Rod subsets

15
15
15
15
15
15
15
15
16
16
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
14
14
14
14
14
14
15
15
15
15
15
15
15
16
16
16
16
15
22
16
16
16
15
17
17
17
17
17

4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-3
4-4-4-4
4-4-4-4
4-4-4-5
4-4-4-5
4-4-4-5
4-4-4-5
4-4-4-5
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
5-4-4-4
3-3-4-4
3-3-4-4
3-3-4-4
3-3-4-4
3-3-4-4
3-3-4-4
3-4-4-4
3-4-4-4
3-4-4-4
3-4-4-4
3-4-4-4
3-4-4-4
3-4-4-4
4-4-4-4
4-4-4-4
4-4-4-4
4-4-4-4
4-4-4-3
5-5-5-4-3
4-4-4-4
4-4-4-4
4-4-4-4
4-4-4-3
4-4-4-5
4-4-4-5
4-4-4-5
4-4-4-5
4-4-4-5

Sanding

x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x

x
x
x

x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x

Mass/ pcs
kg
0,65
0,93
1,11
1,85
2,55
2,95
3,89
4,64
1,98
2,78
1,27
2,10
2,73
2,94
3,15
0,74
1,05
1,15
1,26
1,57
2,10
2,20
2,30
2,80
3,04
3,27
4,22
4,62
4,83
5,77
1,28
1,92
4,40
5,50
6,16
8,71
1,31
2,24
2,80
4,67
5,79
6,54
9,51
1,40
2,00
2,40
3,90
4,68
4,00
6,20
6,60
7,00
9,40
1,47
2,10
2,55
5,31
6,50

35 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
RW 252 350 lis
RW 252 510 lis
RW 270 070 lis
RW 270 120 lis
RW 270 310 lis
RW 270 350 lis
RW 285 400 lis
RW 306 070 lis
RW 306 120 lis
RW 306 330 lis
RW 306 380 lis
RW 306 400 lis
RW 326 350 lis

Clamping range
mm
23,8
25,2
23,8
25,2
25,0
27,0
25,0
27,0
25,0
27,0
25,0
27,0
26,5
28,5
28,5
30,6
28,5
30,6
28,5
30,6
28,5
30,6
28,6
30,6
30,6
32,6

Dia. of rods
mm
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65
4,65

L
mm
3500
5100
700
1200
3100
3500
4000
700
1200
3300
3800
4000
3500

No. of rods

Rod subsets

Sanding

17
17
18
18
18
18
19
20
20
20
20
20
21

4-4-4-5
4-4-4-5
5-5-4-4
5-5-4-4
5-5-4-4
5-5-4-4
4-4-4-4-3
4-4-4-4-4
4-4-4-4-4
4-4-4-4-4
4-4-4-4-4
4-4-4-4-4
4-4-4-4-5

x
x

x
x
x

x
x
x
x

Mass/ pcs
kg
7,30
10,30
1,53
2,63
6,80
7,65
9,40
1,73
2,96
8,16
9,40
9,80
9,22

Material:
Helical rods: Aluminium-clad steel
Application:
Protection rods are preferably made of Aluminium-clad steel-wires and shall protect the self supporting fibre optical aerial cables at
tension sets. They are mounted beneath the helical dead end and spread the radial forces on the cable uniformly along the zone of
contact.
Especially on the cable at the loop-side of the helical dead end radial forces (depending on the tension force) can stress the optical part
of the cable inadmissibly. This will cause high damping which results in a reduced data transmission or in the worst case an
interruption.
The length of the cable guard is determined in such a way that two vibration dampers can be mounted on the rods at the span-side
avoiding that the damper clamp is stressing the optical part of the cable.
For optical fibre aerial cables with right-hand outer layer, cableguards with left-hand layer are always used in order to avoid a torsion of
the cable by the helical dead end with right-hand layer. A torsion of the aerial cable is causing an enlenghtening leading to a destruction
of the optical part of the cable.
Installation:
The helical rods can be wrapped on by hand in bundles. Tools are not required for the assembly. Prior to installation the cable must be
cleaned along the overall lenght of protection rods.

Fig.: Mounting example

1 ..... Thimble
2 ..... Protection rods
3 ..... Helical dead end
Remarks:
These protection rods designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay
cables are required this must be specifically stated when placing the order.
Order example: RW 237 350 s

Stand: 18. Dezember 2009


Pfad: Optofit/ Fittings for tension towers/ RW-Protection rods/
Gedruckt am: 08. Januar 2010

36 / 117

ONLINE-CATALOGUE
B813/1 Helical dead ends (AG) for OPGW

1 ..... Helical dead end


2 ..... Thimble
3 ..... Black crossing mark
RIBE-Order-No.

Clamping range
mm

Dia. of rods

AG 165 103
AG 172 111
AG 193 117
AG 214 122
AG 225 128
AG 237 135
AG 252 143
AG 270 150
AG 285 160
AG 305 173
AG 326 199

14,5 - 16,5
15,2 - 17,2
17,3 - 19,3
19,4 - 21,4
20,5 - 22,5
21,7 - 23,7
23,2 - 25,2
25,0 - 27,0
26,5 - 28,5
28,5 - 30,5
30,6 - 32,6

2,59
2,59
3,02
3,02
3,02
3,51
3,51
3,51
3,51
3,51
4,37

L1
mm
1030
1110
1170
1220
1280
1350
1430
1500
1600
1730
1990

L2
mm
1080
1160
1220
1270
1330
1400
1490
1560
1660
1790
2050

No. of rods
8
8
8
9
10
9
10
10
11
11
9

Thimble
RIBE-No.

F 2685/3

F 2686/2

Mass/ pcs
kg
0,72
0,78
1,16
1,38
1,59
2,03
2,39
2,51
2,94
3,17

F 3246/2

Material:
Helical rods: Steel, h.d.g.
Thimble: Malleable cast iron, h.d.g.
Application:
See data-sheet B810
Remarks:
When selecting the helical dead ends the total diameter resulting out of the cable diameter plus two times the rod diameter of the
protection rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821).
For installation follow RIBE-Mounting Instruction No. 9.
These dead end designs are only suitable for cables of right-hand lay armoring. If dead ends for left-hand lay cables are required this
must be specifically stated when placing the order.
Order example: AG 165 103 lis
Thimbles: see data-sheet B821

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ Helical dead ends (AG) for OPGW/
Gedruckt am: 08. Januar 2010

37 / 117

ONLINE-CATALOGUE
B813/2 AG-Helical dead ends for short span lengths (up to 70 m) and ADSS

1 ..... Thimble
2 ..... Helical dead end
3 ..... Black crossing mark
RIBE-Orderno.
AG 083 039 s
AG 089 043 s
AG 097 046 s
AG 105 050 s
AG 113 054 s
AG 122 058 s
AG 132 058 s
AG 143 063 s
AG 155 068 s
AG 167 073 s
AG 181 079 s
AG 195 086 s
AG 211 092 s
AG 228 100 s
AG 246 108 s
AG 266 117 s
AG 288 126 s

Clamping range
mm
7,71 - 8,31
8,32 - 8,99
9,00 - 9,72
9,73 - 10,51
10,52 - 11,36
11,37 - 12,28
12,29 - 13,27
13,28 - 14,35
14,36 - 15,50
15,51 - 16,75
16,76 - 18,11
18,12 - 19,57
19,58 - 21,14
21,15 - 22,84
22,85 - 24,68
24,69 - 26,67
26,68 - 28,80

Dia. of rods
mm
2,18
2,54
2,54
2,54
2,54
3,02
3,02
3,02
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51

L
mm
395
430
465
500
540
585
580
630
680
735
795
860
925
1000
1080
1170
1265

No. of rods
4
4
4
4
5
4
5
5
5
5
5
5
6
6
7
7
8

Thimble
Sheet metal
B 822 002
B 822 002
B 822 002
B 822 002
B 822 002
B 822 002
F 10 186
F 10 186
F 10 186
F 10 186
F 10 187
F 10 187
F 10 187
F 10 187
after inquiry
after inquiry
after inquiry

Thimble
casted

F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3

Mass/pcs
kg
0,10
0,15
0,16
0,17
0,23
0,28
0,35
0,38
0,56
0,60
0,65
0,70
0,90
0,97
1,22
1,32
1,64

Material:
Helical rods: Steel, h.d.g.
Thimble: Steel,h.d.g.; malleable cast iron, h.d.g.
Application:
These dead ends are designed for the full tensioning of ADSS cables in short span lengths up to 70 m. The loop of the dead end can be
protected against abrasion by a thimble.

Stand: 07. Oktober 2008


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for short span lengths (up to 70 m) and ADSS/
Gedruckt am: 08. Januar 2010

38 / 117

ONLINE-CATALOGUE
Fig.: Mounting example

Remarks:
For installation follow RIBE-Mounting Instruction No. 9. Furthermore the rated forces of thimbles are observed (see data-sheet B821).
Thimbles: see data-sheet B821-B822

Stand: 07. Oktober 2008


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for short span lengths (up to 70 m) and ADSS/
Gedruckt am: 08. Januar 2010

39 / 117

ONLINE-CATALOGUE
B813/3 AG-Helical dead ends for all span lengths

1 ..... Helical dead end


2 ..... Red crossing mark
3 ..... Black crossing mark
RIBE-Order-No.

Clamping range

Dia. of rods

No. of rods

Thimble
Sheet metal

AG 097 062 s
AG 105 067 s
AG 113 072 s
AG 122 078 s
AG 132 079 s
AG 143 086 s
AG 155 093 s
AG 167 100 s
AG 181 108 s
AG 195 117 s
AG 211 126 s
AG 228 137 s
AG 246 148 s
AG 266 160 s
AG 288 172 s
AG 311 186 s

mm
9,00 - 9,72
9,73 - 10,51
10,52 - 11,36
11,37 - 12,28
12,29 - 13,27
13,28 - 14,35
14,36 - 15,50
15,51 - 16,75
16,76 - 18,11
18,12 - 19,57
19,58 - 21,14
21,15 - 22,84
22,85 - 24,68
24,69 - 26,67
26,68 - 28,81
28,82 - 31,13

mm
2,54
2,54
2,54
3,02
3,02
3,02
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51

mm
620
670
725
785
795
860
930
1005
1085
1175
1265
1370
1480
1600
1725
1865

4
4
5
4
5
5
5
5
5
5
6
6
7
7
8
8

B 822 002
B 822 002
B 822 002
B 822 002
F 10186
F 10186
F 10186
F 10186
F 10187
F 10187
F 10187
F 10187
F 10187
F 10187
F 10187
F 10187

Thimble
casted

F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3
F 2685/3

Mass/ pcs
kg
0,21
0,23
0,29
0,38
0,48
0,52
0,76
0,82
0,88
0,96
1,23
1,33
1,68
1,81
2,23
2,41

Material:
Helical rods: Steel, h.d.g.
Thimble: Steel, h.d.g.; malleable cast iron, h.d.g.
Application:
These dead ends are particulary designed for the full tensioning of ADSS cable in short, medium and long spans. Three ways of
application are possible:
for short spans (up to approx. 70m) and small forces: :
The dead end is mounted on the cable starting at the black crossing mark. This leads to a long cable loop and a large bending radius of
the cable. A thimble can be used in the loop of the dead end.

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for all span lengths/
Gedruckt am: 08. Januar 2010

40 / 117

ONLINE-CATALOGUE

for medium spans (approx. 70 - 150 m) and high forces:


The dead end is mounted on the cable starting at the red crossing mark. This leads to a short cable loop. Additional intermediate fittings
for installation at the tower and a thimble are necessary.

for long spans and high forces:


The use of protection rods (URA: see data-sheet B814/1) is recommended. When selecting the helical dead ends the total diameter
resulting out of the cable diameter plus two times the rod diameter of protection rods has to be taken into account.
Remarks:
For installation follow RIBE-Mounting Instruction No. 9. Furthermore the rated forces of thimbles are observed (see data-sheet B821).
Sheet thimbles: see data-sheet B822
Casted thimbles: see data-sheet B821

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for all span lengths/
Gedruckt am: 08. Januar 2010

41 / 117

ONLINE-CATALOGUE
B813/4 AG-Helical dead ends for Figure-8-cables with separate left-hand layer support

1 ..... Helical dead end


2 ..... Supporting cable
3 ..... Black crossing mark
RIBE-Order-No.

For steel support cable


No. of wires

AG 030 032 li
AG 040 043 li
AG 044 046 li
AG 050 052 li
AG 062 061 li
AG 076 069 li

7 x 1,0 mm
10 x 1,0 mm
14 x 1,0 mm
19 x 1,0 mm
19 x 1,2 mm
19 x 1,5 mm

Dia. without insulation


mm
3,0
4,0
4,4
5,0
6,0
7,5

Color of marker

black
yellow
blue
red
green
orange

Dia. of rods

No. of rods

mm
1,55
1,78
1,78
2,18
2,18
2,54

mm
315
425
455
515
605
690

3
4
4
4
5
5

Mass/
pcs
kg
0,04
0,07
0,08
0,14
0,20
0,31

Material:
Helical rods: Steel, h.d.g.
Application:
These dead ends are designed for the full tensioning of the separate support cable (left-hand outer layer). The advantage of dead ends
compared with tensioning devices commonly used is that there is no bending of the relatively stiff supporting cable. It is recommended
to protect the dead end loop from abrasion by means of a thimble.
These dead ends can be used to suspend self supporting figure-8-cables too. Two dead ends per suspension point are required for any
such application (see figure below).

Fig.: Mounting example for suspending self supporting cables

Installation:
Dead ends can be installed and removed quickly and without application of any tools. Wrapping of dead ends starts at the crossing

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for Figure-8-cables with separate left-hand layer support/
Gedruckt am: 08. Januar 2010

42 / 117

ONLINE-CATALOGUE
mark.
For installation follow RIBE-Mounting Instruction No. 9.
Remarks:
These dead end designs are only suitable for left-hand layer steel support cables. When placing an order please state if dead ends for
righthand layer support cables are required.
Thimbles: see data-sheet B822

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends for Figure-8-cables with separate left-hand layer support/
Gedruckt am: 08. Januar 2010

43 / 117

ONLINE-CATALOGUE
B813/6 AG-Helical dead ends

1 ..... Helical dead end


2 ..... Thimble
3 ..... Black crossing mark
RIBE-Order-No.

Clamping range

AG 121 075 s
AG 128 080 s
AG 135 084 s
AG 142 089 s
AG 150 094 s
AG 159 099 s
AG 168 098 s
AG 177 103 s
AG 187 109 s
AG 197 115 s
AG 208 122 s
AG 220 128 s
AG 232 136 s
AG 245 143 s
AG 258 151 s
AG 273 159 s
AG 288 168 s
AG 304 178 s
AG 321 187 s
AG 338 198 s
AG 357 209 s
AG 377 220 s

11,50
12,14
12,82
13,54
14,29
15,09
15,93
16,81
17,75
18,73
19,77
20,87
22,03
23,25
24,54
25,90
27,33
28,85
30,44
32,13
33,90
35,78

Dia. of rods

L1

L2

No. of rods

3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
3,51
4,37
4,37
4,37
4,37
4,37
4,37
4,37
4,37
4,37
4,37
5,18
5,18

mm
755
800
845
890
940
990
980
1035
1095
1155
1220
1285
1360
1435
1515
1595
1685
1780
1875
1980
2090
2205

mm
805
850
895
1040
990
1040
1030
1085
1145
1205
1270
1335
1420
1495
1575
1755
1745
1840
1945
2050
2160
2275

5
6
6
6
6
6
6
6
7
7
6
6
6
7
7
7
8
8
9
9
10
10

12,13
12,81
13,53
14,28
15,08
15,92
16,80
17,74
18,72
19,76
20,86
22,02
23,24
24,53
25,89
27,32
28,84
30,43
32,12
33,89
35,77
37,75

Thimble
RIBE-No.

Mass/ pcs
kg

F 2685/3

F 2685/3

F 2686/2

F 3246/2

0,62
0,79
0,84
0,88
0,93
0,97
0,96
1,01
1,25
1,32
1,86
1,95
2,06
2,54
2,67
2,81
3,39
3,58
4,24
4,47
7,38
7,78

Material:
Helical rods: Steel, h.d.g.
Thimble: Malleable cast iron, h.d.g.

Stand: 04. Mai 2007


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends/
Gedruckt am: 08. Januar 2010

44 / 117

ONLINE-CATALOGUE
Application:
See data-sheet B810
Remarks:
When selecting helical dead ends the total diameter resulting from the cable diameter plus two times the rod diameter of the protection
rods has to be taken into account. Furthermore the rated forces of thimbles are observed (see data-sheet B821).
For installation follow RIBE-Mounting Instruction No. 9.
These dead end designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay
cables are required this must specifically be stated when placing the order.
Order example: AG 177 103 s
Thimbles: see data-sheet B821

Stand: 04. Mai 2007


Pfad: Optofit/ Fittings for tension towers/ AG-Helical dead ends/
Gedruckt am: 08. Januar 2010

45 / 117

ONLINE-CATALOGUE
B814/1 URA-Protection rods for ADSS cables and spans longer than 150 m

RIBE-Order-No.

Clamping range

Dia. of rods

URA 077 110 lis


URA 082 114 lis
URA 087 117 lis
URA 093 122 lis
URA 098 126 lis
URA 104 131 lis
URA 111 141 lis
URA 118 146 lis
URA 125 152 lis
URA 132 158 lis
URA 140 168 lis
URA 149 175 lis
URA 158 182 lis
URA 168 189 lis
URA 178 200 lis
URA 189 208 lis
URA 200 217 lis
URA 212 226 lis
URA 225 236 lis

mm
7,35 - 7,79
7,80 - 8,27
8,28 - 8,78
8,79 - 9,31
9,32 - 9,88
9,89 - 10,49
10,50 - 11,13
11,14 - 11,80
11,81 - 12,52
12,53 - 13,28
13,29 - 14,09
14,10 - 14,95
14,96 - 15,86
15,87 - 16,82
16,83 - 17,84
17,85 - 18,92
18,93 - 20,06
20,07 - 21,28
21,29 - 22,57

mm
2,59
2,59
2,59
2,59
2,59
2,59
3,07
3,07
3,07
3,07
3,45
3,45
3,45
3,45
3,70
3,70
3,70
3,70
3,70

No. of rods

Subsets

10
10
11
11
12
13
12
12
13
13
13
14
14
15
15
16
16
17
18

3-3-4
3-3-4
3-4-4
3-4-4
4-4-4
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-5-5
4-5-5
5-5-5
5-5-5
4-4-4-4
4-4-4-4
4-4-4-5
4-4-5-5

mm
1105
1141
1180
1221
1264
1310
1416
1468
1523
1581
1688
1753
1823
1896
2004
2086
2173
2266
2364

Mass/
pcs
kg
0,17
0,18
0,20
0,21
0,23
0,26
0,37
0,38
0,43
0,44
0,60
0,67
0,69
0,77
0,94
1,04
1,08
1,20
1,32

Material:
Helical rods: Aluminium alloy
Application:
Cable guards protect the ADSS cables at the tension assembly. They are mounted under the helical dead end and reduce the radial
forces in the cable - especially at the loopside of the dead end.
Radial forces (depending on the tension force) can stress the optical part of the cable inadmissibly. This can cause high damping in the
optical fibre. This results in a high signal damping in the optical fibre up to an interruption of the optical transmission.
Installation:
The helical rods can be wrapped on by hand in bundles. Tools are not required for installation.

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ URA-Protection rods for ADSS cables and spans longer than 150 m/
Gedruckt am: 08. Januar 2010

46 / 117

ONLINE-CATALOGUE
Fig.: Mounting example

1 ..... Thimble
2 ..... Protection rods
3 ..... Helical dead end
Remarks:
Helical dead ends: see data-sheet B813/3
Order example: URA 077 110 lis

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ URA-Protection rods for ADSS cables and spans longer than 150 m/
Gedruckt am: 08. Januar 2010

47 / 117

ONLINE-CATALOGUE
B814/2 UTA-Protection rods for ADSS cables and medium span lengths (70 - 150 m)

RIBE-Order-No.
UTA 077 125 lis
UTA 082 126 lis
UTA 087 128 lis
UTA 093 130 lis
UTA 098 132 lis
UTA 104 134 lis
UTA 111 164 lis
UTA 118 166 lis
UTA 125 168 lis
UTA 132 171 lis
UTA 140 174 lis
UTA 149 176 lis
UTA 158 179 lis
UTA 168 229 lis
UTA 178 233 lis
UTA 189 327 lis
UTA 200 331 lis
UTA 212 335 lis

Clamping range
mm
7,35 - 7,79
7,80 - 8,27
8,28 - 8,78
8,79 - 9,31
9,32 - 9,88
9,89 - 10,49
10,50 - 11,13
11,14 - 11,80
11,81 - 12,52
12,53 - 13,28
13,29 - 14,09
14,10 - 14,95
14,96 - 15,86
15,87 - 16,82
16,83 - 17,84
17,85 - 18,92
18,93 - 20,06
20,07 - 21,28

Dia. of rods
mm
2,59
2,59
2,59
2,59
2,59
2,59
3,07
3,07
3,07
3,07
3,45
3,45
3,45
3,45
3,70
3,70
3,70
3,70

No. of rods

Subsets

10
10
11
11
12
13
12
12
13
13
13
14
14
15
15
16
16
17

3-3-4
3-3-4
3-4-4
3-4-4
4-4-4
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-5-5
4-5-5
5-5-5
5-5-5
4-4-4-4
4-4-4-4
4-4-4-5

mm
1254
1270
1287
1304
1323
1342
1643
1665
1689
1714
1740
1768
1798
2299
2332
3278
3315
3355

Mass/ pcs
kg
0,20
0,20
0,22
0,22
0,24
0,27
0,43
0,43
0,47
0,48
0,62
0,67
0,68
0,94
1,09
1,63
1,65
1,77

Material:
Helical rods: Aluminium alloy
Application:
Protection rods are mounted under the suspension rods to protect the ADSS cable. They reduce radial forces in the cable and increase
- due to the increased bending stiffness - the bending radius of the ADSS cable.
Installation:
The helical rods can be wrapped on by hand in bundles. Tools are not required for installation.

Fig.: Mounting example

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ UTA-Protection rods for ADSS cables and medium span lengths (70 - 150 m)/
Gedruckt am: 08. Januar 2010

48 / 117

ONLINE-CATALOGUE
1 ..... UTA-Protection rods
2 ..... Hook
3 ..... TG-Suspension rods
Remarks:
Order example: UTA 077 125 lis
Suspension rods: see data-sheet B805/2
Installation instructions: see data-sheet Mon69

Stand: 10. August 2006


Pfad: Optofit/ Fittings for tension towers/ UTA-Protection rods for ADSS cables and medium span lengths (70 - 150 m)/
Gedruckt am: 08. Januar 2010

49 / 117

ONLINE-CATALOGUE
B814/3 Patch rods

RIBE-Order-No.

Clamping range
Dia. of rods
mm
mm
RA 077 113 s
7,35 7,79
2,59
RA 082 117 s
7,80 - 8,27
2,59
RA 087 121 s
8,28 8,78
2,59
RA 093 126 s
8,79 - 9,31
2,59
RA 098 130 s
9,32 9,88
3,07
RA 104 135 s
9,89 10,49
3,07
RA 111 140 s
10,50 11,13
3,45
RA 118 146 s
11,14 - 11,80
3,45
RA 125 152 s
11,81 12,52
3,45
RA 132 158 s
12,53 13,28
4,24
RA 140 165 s
13,29 14,09
4,24
RA 149 172 s
14,10 14,95
4,62
RA 158 179 s
14,96 15,86
4,62
RA 168 187 s
15,87 16,82
4,62
RA 178 195 s
16,83 17,84
5,18
RA 189 204 s
17,85 18,92
6,35
RA 200 213 s
18,93 20,06
6,35
RA 212 223 s
20,07 21,28
6,35
RA 225 234 s
21,29 22,57
6,35
RA 239 245 s
22,58 23,93
7,87
RA 253 257 s
23,94 25,38
7,87
RA 269 269 s
25,39 26,91
7,87
RA 285 282 s
26,92 28,54
9,27
RA 302 296 s
28,55 30,26
9,27
RA 320 311 s
30,27 32,08
9,27
RA 340 327 s
32,09 34,02
9,27
(*) Subsets sanded inside with a small grained metallic (conductive) oxide
(**) Single rods (not sanded), 250 g friction bond a part of delivery

L
mm
1136
1175
1216
1260
1307
1356
1408
1463
1522
1584
1650
1720
1794
1873
1956
2044
2138
2237
2342
2453
2571
2696
2829
2970
3119
3277

No. of rods

Subsets

10
10
11
11
10
11
11
11
11
10
11
11
11
12
11
10
10
11
11
10
10
11
10
11
11
12

3 - 3 4 (*)
3 - 3 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 3 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 3 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
4 - 4 - 4 (*)
3 - 4 - 4 (*)
3 - 3 - 4 (*)
3 - 3 - 4 (*)
3 - 4 - 4 (*)
3 - 4 - 4 (*)
(**)
(**)
(**)
(**)
(**)
(**)
(**)

Mass/ pcs
kg
0,18
0,18
0,21
0,21
0,28
0,32
0,43
0,44
0,46
0,66
0,75
0,93
0,97
1,10
1,33
1,91
1,99
2,29
2,39
3,52
3,68
4,24
5,63
6,48
6,79
7,77

Material:
Helical rods: Aluminium alloy
Application:
Patch rods are used to repair damaged OPGW (up to 100 % of the outside layer) and are preferably employed in the free span. Patch
rods are capable to restore the electrical conductivity and mechanical strength securing thus the full performance of OPGW. The length
of the patch rods was determined in such a way, that a damaged place up to 50 cm is covered. In case of larger damaged areas longer
special rods are necessary.
Installation:

Stand: 06. Februar 2007


Pfad: Optofit/ Fittings for tension towers/ Patch rods/
Gedruckt am: 08. Januar 2010

50 / 117

ONLINE-CATALOGUE
he helical rods can be wrapped on by hand in bundles. Tools are not required for installation. The rods have to be installed in such a
way that the middle mark of the rods are in the center of the damaged area.
Rods of diameters of more than 7 mm must singly be wrapped on. Prior to wrapping on the single rods, the outer layer of OPGW must
be cleaned and be covered with friction bond. The friction bond is enclosed on delivery.
For installation follow RIBE-Mounting Instruction No. 14.

Stand: 06. Februar 2007


Pfad: Optofit/ Fittings for tension towers/ Patch rods/
Gedruckt am: 08. Januar 2010

51 / 117

ONLINE-CATALOGUE
B816/1 Tension supports for optical fibre aerial cables and ACSR conductors

1 ..... Boreholes for parallel groove clamp on request. Dimensions are required!
RIBE-Order-No.
Rated force Mass/ pcs
Remarks
FN
d
mm
kN
kg
F 13 804/1
20
F 13 804/2
24
150
3,9
F 13 804/3
--- without double eyes, including boreholes for parallel groove clamp (M12, a = 50 mm)
F 13 804/4
20
- including boreholes for parallel groove clamp (M12, a = 50 mm)

Material:
Support: Malleable cast iron, h.d.g.
Double eyes: Forged steel, h.d.g.
Bolts: Steel, grade 8.8, h.d.g.
Application:
Tension supports are used to tension optical fibre aerial cables and ACSR conductors. They are typically applied on top of tension
towers.
Remark:
For other executions please inquire.

Stand: 26. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ Tension supports for optical fibre aerial cables and ACSR conductors/
Gedruckt am: 08. Januar 2010

52 / 117

ONLINE-CATALOGUE
B816/2 Tension supports with parallel groove clamps for optical fibre aerial cables and
ACSR conductors

1 ..... Groove A
2 ..... Groove B
RIBE-Order-No..
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Clamping range of groove A


mm
8,00 8,5
8,51 9,0
9,01 9,5
9,51 10,0
10,01 10,5
10,51 11,0
11,01 11,5
11,51 12,0
12,01 12,5
12,51 13,0
13,01 13,5
13,51 14,0
14,01 14,5
14,51 15,0
15,01 15,5
15,51 16,0

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Clamping range of groove B


mm
8,00 8,5
8,51 9,0
9,01 9,5
9,51 10,0
10,01 10,5
10,51 11,0
11,01 11,5
11,51 12,0
12,01 12,5
12,51 13,0
13,01 13,5
13,51 14,0
14,01 14,5
14,51 15,0
15,01 15,5
15,51 16,0

Stand: 26. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/
Gedruckt am: 08. Januar 2010

Mass/ pcs
kg

53 / 117

ONLINE-CATALOGUE
RIBE-Order-No..
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb
B 816 005/1 A... B... Kb

Exe.
17
18
19
20
21
22
23
24
25
26
27
28
29

Clamping range of groove A


mm
16,01 16,5
16,51 17,0
17,01 17,5
17,51 18,0
18,01 18,5
18,51 19,0
19,01 19,5
19,51 20,0
20,01 20,5
20,51 21,0
21,01 21,5
21,51
22,0
22,01 22,5

Exe.
17
18
19
20
21
22
23
24
25
26
27
28
29

Clamping range of groove B


mm
16,01 16,5
16,51 17,0
17,01 17,5
17,51 18,0
18,01 18,5
18,51 19,0
19,01 19,5
19,51 20,0
20,01 20,5
20,51 21,0
21,01 21,5
21,51
22,0
22,01 22,5

Mass/ pcs
kg

Material:
Support: Malleable cast iron, h.d.g.
Double eyes: Forged steel, h.d.g.
Bolts: Steel, grade 8.8, h.d.g.
Clamp body: Aluminium, forged
Bolts, nuts: M10, stainless steel
Application:
Tension supports are used to tension and earthing optical fibre aerial cables and ACSR conductors. They are typically applied on top of
tension towers.
Remarks:
Recommended tightening torque of bolts, M10: 46 Nm
The exact diameter of grooves A and B are needed when placing an order of tension support with parallel groove clamp acc. to RIBENo. B 816 005.
Order example:
Groove A: 15,8 mm dia.
Groove B: 21,2 mm dia.
Parallel groove clamp: B 816 005/1 A16 B27 Kb
For other executions please inquire.
Filler bolts: see data-sheet B816/3

Fig.: Mounting example

1 ..... OPGW
2 ..... Tension support with parallel groove clamp
3 ..... Filler bolt

Stand: 26. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/
Gedruckt am: 08. Januar 2010

54 / 117

ONLINE-CATALOGUE
B816/3 Filler bolts for tension supports with parallel groove clamps

Clamping range
mm
8,00 - 8,5
8,51 - 9,0
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5

RIBE-Order-No.
B 816 005-01/01
B 816 005-01/02
B 816 005-01/03
B 816 005-01/04
B 816 005-01/05
B 816 005-01/06
B 816 005-01/07
B 816 005-01/08
B 816 005-01/09
B 816 005-01/10
B 816 005-01/11
B 816 005-01/12
B 816 005-01/13
B 816 005-01/14
B 816 005-01/15
B 816 005-01/16
B 816 005-01/17

d
mm
7,9
8,4
8,9
9,4
9,9
10,4
10,9
11,4
11,9
12,4
12,9
13,4
13,9
14,4
14,9
15,4
15,9

Mass/ pcs
kg

Clamping range
mm
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5
22,51 - 23,0
23,01 - 23,5
23,51 - 24,0
24,01 - 24,5

RIBE-Order-No.
B 816 005-01/18
B 816 005-01/19
B 816 005-01/20
B 816 005-01/21
B 816 005-01/22
B 816 005-01/23
B 816 005-01/24
B 816 005-01/25
B 816 005-01/26
B 816 005-01/27
B 816 005-01/28
B 816 005-01/29
B 816 005-01/30
B 816 005-01/31
B 816 005-01/32
B 816 005-01/33

d
mm
16,4
16,9
17,4
17,9
18,4
18,9
19,4
19,9
20,4
20,9
21,4
21,9
22,4
22,9
23,4
23,9

Mass/ pcs
kg

Material:
Filler bolt: Aluminium alloy
Application:
Insert filler bolt in the second groove of the parallel groove clamp in case of earthing of one optical fibre aerial cable on the top of the
tower.
Remarks:
Tension supports with parallel groove clamps: see data-sheet B816/2 and B816/4
For other executions please inquire.

Stand: 09. Februar 2009


Pfad: Optofit/ Fittings for tension towers/ Filler bolts for tension supports with parallel groove clamps/
Gedruckt am: 08. Januar 2010

55 / 117

ONLINE-CATALOGUE
B816/4 Tension supports with parallel groove clamps for optical fibre aerial cables and
ACSR conductors

1 ..... Groove A
2 ..... Groove B
RIBE-Order-No.
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Clamping range of groove A


mm
8,00 8,5
8,51 9,0
9,01 9,5
9,51 10,0
10,01 10,5
10,51 11,0
11,01 11,5
11,51 12,0
12,01 12,5
12,51 13,0
13,01 13,5
13,51 14,0
14,01 14,5
14,51 15,0
15,01 15,5
15,51 16,0

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Clamping range of groove B


mm
8,00 8,5
8,51 9,0
9,01 9,5
9,51 10,0
10,01 10,5
10,51 11,0
11,01 11,5
11,51 12,0
12,01 12,5
12,51 13,0
13,01 13,5
13,51 14,0
14,01 14,5
14,51 15,0
15,01 15,5
15,51 16,0

Stand: 26. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/
Gedruckt am: 08. Januar 2010

Mass/ pcs
kg

56 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb
B 816 005/2 A... B... Kb

Exe.
17
18
19
20
21
22
23
24
25
26
27
28
29

Clamping range of groove A


mm
16,01 16,5
16,51 17,0
17,01 17,5
17,51 18,0
18,01 18,5
18,51 19,0
19,01 19,5
19,51 20,0
20,01 20,5
20,51 21,0
21,01 21,5
21,51
22,0
22,01 22,5

Exe.
17
18
19
20
21
22
23
24
25
26
27
28
29

Clamping range of groove B


mm
16,01 16,5
16,51 17,0
17,01 17,5
17,51 18,0
18,01 18,5
18,51 19,0
19,01 19,5
19,51 20,0
20,01 20,5
20,51 21,0
21,01 21,5
21,51
22,0
22,01 22,5

Mass/ pcs
kg

Material:
Support: Malleable cast iron, h.d.g.
Double eyes: Forged steel, h.d.g.
Bolts: Steel, grade 8.8, h.d.g.
Clamp body: Aluminium, forged
Bolts, nuts: M10, stainless steel
Application:
Tension supports are used to tension and earthing optical fibre aerial cables and ACSR conductors. They are typically applied on top of
tension towers.
Remarks:
Recommended tightening torque of bolts, M10: 46 Nm
The exact diameter of grooves A and B are needed when placing an order of tension support with parallel groove clamp acc. to RIBENo. B 816 005.
Order example:
Groove A: 15,8 mm dia.
Groove B: 21,2 mm dia.
Parallel groove clamp: B 816 005/2 A16 B27 Kb
For other executions please inquire.
Filler bolts: see data-sheet B816/3

Fig.: Mounting example

1 ..... OPGW
2 ..... Tension support with parallel groove clamp
3 ..... Filler bolt

Stand: 26. Juli 2007


Pfad: Optofit/ Fittings for tension towers/ Tension supports with parallel groove clamps for optical fibre aerial cables and ACSR conductors/
Gedruckt am: 08. Januar 2010

57 / 117

ONLINE-CATALOGUE
B818 URG-Protection rods

RIBE-Order-No.
URG 094 122 lis
URG 099 126 lis
URG 105 131 lis
URG 112 136 lis
URG 119 141 lis
URG 126 146 lis
URG 134 152 lis
URG 142 164 lis
URG 151 171 lis
URG 160 178 lis
URG 169 185 lis
URG 180 193 lis
URG 191 202 lis
URG 202 227 lis
URG 215 236 lis
URG 228 246 lis
URG 241 256 lis
URG 256 267 lis
URG 271 279 lis
URG 288 292 lis
URG 305 305 lis

Clamping range
mm
8,88 - 9,41
9,42 - 9,99
10,00 - 10,60
10,61 - 11,25
11,26 11,93
11,94 - 12,66
12,67 13,43
13,44 - 14,24
14,25 15,11
15,12 16,03
16,04 17,00
17,01 - 18,03
18,04 - 19,12
19,13 20,28
20,29 - 21,51
21,52 22,81
22,82 - 24,19
24,20 - 25,65
25,66 - 27,20
27,21 28,84
28,85 - 30,58

Dia. of rods
mm
2,54
2,54
2,54
2,54
2,54
2,54
2,54
3,02
3,02
3,02
3,02
3,02
3,02
4,37
4,37
4,37
4,37
4,37
4,37
4,37
4,37

L
mm
1220
1260
1310
1360
1410
1470
1530
1650
1710
1790
1860
1940
2020
2270
2360
2460
2560
2680
2790
2920
3050

No. of rods

Rod subsets

12
12
13
14
15
15
16
15
15
16
17
18
19
14
14
15
16
17
18
19
20

4-4-4
4-4-4
4-4-5
4-5-5
5-5-5
5-5-5
4-4-4-4
5-5-5
5-5-5
4-4-4-4
4-4-4-5
4-4-5-5
5-5-5-4
4-4-3-3
4-4-3-3
4-4-4-3
4-4-4-4
5-4-4-4
3-3-4-4-4
5-5-5-4
4-4-4-4-4

Mass/ pcs
Kg
0,63
0,65
0,73
0,82
0,91
0,94
1,04
1,50
1,55
1,72
1,90
2,10
2,30
4,03
4,19
4,67
5,18
5,74
6,33
6,98
7,67

Material:
Helical rods: Steel, h.d.g.
Application:
Protection rods are preferably made of steel, h.d.g. and shall protect the self supporting fibre optical aerial cables at tension sets. They
are mounted beneath the helical dead end and spread the radial forces on the cable uniformly along the zone of contact.
Especially on the cable at the loop-side of the helical dead end radial forces (depending on the tension force) can stress the optical part
of the cable inadmissibly. This will cause high damping which results in a reduced data transmission or in the worst case an
interruption.
The length of the cable guard is determined in such a way that two vibration dampers can be mounted on the rods at the span-side
avoiding that the damper clamp is stressing the optical part of the cable.
For optical fibre aerial cables with right-hand outer layer, cableguards with left-hand layer are always used in order to avoid a torsion of
the cable by the helical dead end with right-hand layer. A torsion of the aerial cable is causing an enlenghtening leading to a destruction
of the optical part of the cable.
Installation:
The helical rods can be wrapped on by hand in bundles. Tools are not required for the assembly. Prior to installation the cable must be
cleaned along the overall lenght of protection rods.

Stand: 10. Mai 2006


Pfad: Optofit/ Fittings for tension towers/ URG-Protection rods/
Gedruckt am: 08. Januar 2010

58 / 117

ONLINE-CATALOGUE

Fig.: Mounting example

1 ..... Thimble
2 ..... Protection rods
3 ..... Helical dead end
Remarks:
These protection rods designs are only suitable for cables with right-hand lay armoring and ADSS cables. If dead ends for left-hand lay
cables are required this must be specifically stated when placing the order.
Order example: URG 169 185 s

Stand: 10. Mai 2006


Pfad: Optofit/ Fittings for tension towers/ URG-Protection rods/
Gedruckt am: 08. Januar 2010

59 / 117

ONLINE-CATALOGUE
B821 Thimbles for helical dead ends for OPGW and ADSS

RIBE-Order-No.
F 2684/3

Suitable for helical dead ends with clamping range


mm
6,8 - 15,09

r
mm
25

d
mm
19

Rated force
kN
100

Mass/ pcs
kg
0,85

F 2685/3
F 2686/2

15,1 - 22,5
21,7 - 28,5

25
35

19
19

100
200

0,90
1,44

F 3246/2
F 13 552/2

28,5 - 39,0
36,1 - 52,0

38
40

19
22

200
300

1,90
3,50

Material:
Thimbles: Malleable cast iron, h.d.g.
Application:
The thimbles together with helical dead ends serve for the tensioning of self supporting optical fibre aerial cables.
Remark:
Helical dead ends: see data-sheet B810 ff.

Stand: 03. Juli 2007


Pfad: Optofit/ Thimbles/ Thimbles for helical dead ends for OPGW and ADSS/
Gedruckt am: 08. Januar 2010

60 / 117

ONLINE-CATALOGUE
B822 Thimbles for helical dead ends for OPGW and ADSS

RIBE-Order-No.

E 4782
B 822 001
B 822 002
F 10 186
F 10 187
F 13 546

Suitable for helical dead ends with clamping range

6,74 - 11,55
2,00 - 7,5
7,00 - 12,5
12,0 - 19,3

mm
(Loop diameter of helical rods: 50 mm)
(Loop diameter of helical rods: 25 mm)
(Loop diameter of helical rods: 40 mm)

mm
50

mm
20

Mass/
pcs
kg
0,08

25
40

14
21

0,05
0,10

(Loop diameter of helical rods: 50 mm)

16,9 - 32,5

(Loop diameter of helical rods: 50 mm)

50
50

30
44

0,05
0,06

12,0 - 19,3

(Loop diameter of helical rods: 64 mm)

65

32

0,10

Material:
Thimbles: Steel, h.d.g.
Application:
The thimbles together with helical dead ends serve for the tensioning of self supporting optical fibre aerial cables. They are used in
cases of low tension forces (ADSS cables).
Remark:
Helical dead ends: see data-sheet B810 ff.

Stand: 18. August 2006


Pfad: Optofit/ Thimbles/ Thimbles for helical dead ends for OPGW and ADSS/
Gedruckt am: 08. Januar 2010

61 / 117

ONLINE-CATALOGUE
B823 Ring type thimbles for suspension rods for ADSS

RIBE-Order-No.
E 5119
F 12006

Suitable for suspension rods


TG - LG - suspension rods (see data-sheet B805/5)
TG - UTA - suspension rods (see data-sheet B805/2 and B814/2)

a
mm
55
80

b
mm
61
88

c
mm
19
30

Mass/ pcs
kg
0,04
0,10

Material:
Thimbles: Steel, h.d.g.
Application:
These thimbles serve as movable suspension of ADSS cables together with suspension rods. The loop of the suspension rods is
stabilized and protected against abrasion with ring type thimbles.

Stand: 18. August 2006


Pfad: Optofit/ Thimbles/ Ring type thimbles for suspension rods for ADSS/
Gedruckt am: 08. Januar 2010

62 / 117

ONLINE-CATALOGUE
B831 Earthing connections (complete) for loops

1 ..... Parallel groove clamp


2 ..... Shunt
3 ..... Earthing connection
4 ..... OPGW
Earthing connection
RIBE-Order-No.

Diameter of OPGW
Conductor

Shunt
Length

RIBE-No.

Parallel groove clamp


RIBE-No.

mm
F 3141-21/2
F 3141-21/1
F 3141-21/5
F 3141-21/7
F 3141-21/3
F 3141-21/6
F 3141-21/4
F 10 835-30/1
F 10 835-30/2
F 10 833/1

22,6 - 22,7
23,1
23,8
25,1
26,1
28,5
29,9
12,1
12,5 - 12,6
18,4

Al 120 mm - 14,0 mm

1000 mm

F 3140-52/1

Al/St 150/25 mm - 17,1 mm

1000 mm

F 10 835-10/1

Al/St 265/35 mm - 22,4 mm

1000 mm

F 10 833-10/1

F 3141-30/2
F 3141-30/1
F 3141-30/5
F 3141-30/7
F 3141-30/3
F 3141-30/6
F 3141-30/4
F 10 835-31/1
F 10 835-31/2
F 5038-10

Material:
1) Parallel groove clamp
Clamp body: Casted Aluminium
Bolts, nuts: h.d.g., alternatively stainless steel
2) Shunt
ACSR- or Al-conductor
Bolts, nuts: M12, h.d.g., alternatively stainless steel
Application:
The earthing connections consist of one parallel groove clamp and one shunt. They are used to get a defined earthing.
Remarks:
For other executions please inquire.
Parallel groove clamps: see data-sheet B832/1, B832/2 and B832/3
Shunts: see data-sheet B833/1 and B833/2
Order example: F 10 826-10/4 (consisting of shunt F 10 828-52/1 and parallel groove clamp F 10 826-52/4)

Stand: 10. August 2006


Pfad: Optofit/ Earthing material/ Earthing connections (complete) for loops/
Gedruckt am: 08. Januar 2010

63 / 117

ONLINE-CATALOGUE
B832/1 Parallel groove clamps (with 2 bolts)

1 ..... OPGW (groove A)


2 ..... Shunt (groove B)
3 ..... Bolt M10
RIBE-Order-No.
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb
B 832 002/A... B... Kb

Exe.
1
2
3
4
5
6
7
8
9
10
11
12

Clamping range of groove A


mm
8,0 - 8,5
8,51 - 9,0
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0

Exe.
1
2
3
4
5
6
7
8
9
10
11
12

Clamping range of groove B


mm
8,0 - 8,5
8,51 - 9,0
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0

Mass/ pcs
kg

0,26

Material:
Clamp body: Aluminium, forged
Bolts, nuts: Stainless steel
Application:
See data-sheet B831
Remarks:
Recommended tightening torque of bolts, M10: 46 Nm
The exact diameter of grooves A and B are needed when placing an order of parallel groove clamp acc. to RIBE-No. B 832 002.
Order example:
Groove A: 10,8 mm dia.
Groove B: 12,5 mm dia.
Parallel groove clamp: B 832 002/ A6 B9 Kb
For other executions please inquire.
Shunts: see data-sheet B833/1 and B833/2

Stand: 18. Dezember 2009


Pfad: Optofit/ Earthing material/ Parallel groove clamps (with 2 bolts)/
Gedruckt am: 08. Januar 2010

64 / 117

ONLINE-CATALOGUE
B832/2 Parallel groove clamps (with 3 bolts)

1 ..... Groove A
2 ..... Groove B
3 ..... Bolt
RIBE-Order-No.
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)
B 832 001/A... B... Kb 1)

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

Stand: 18. Dezember 2009


Pfad: Optofit/ Earthing material/ Parallel groove clamps (with 3 bolts)/
Gedruckt am: 08. Januar 2010

Clamping range of groove A


mm
8,00 - 8,5
8,51 - 9,0
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5

Exe.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

Clamping range of groove B


mm
8,00 - 8,5
8,51 - 9,0
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5

Mass/ pcs
kg

0,58

65 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
B 832 001/A... B... Kb 1)

Exe.
30

F 3141-30/2 2)
F 3141-30/1 2)
F 3141-30/5 2)
F 3141-30/7 2)
F 3141-30/3 2)

Al 120
mm 14,0
mm

F 3141-30/8 2)
F 3141-30/6 2)
F 3141-30/4 2)

Clamping range of groove A


mm
13,30 - 13,8

Exe.
30
22,6 22,7
23,1
23,8
25,1
26,1

Clamping range of groove B


mm
13,30 - 13,8

Mass/ pcs
kg

0,8

27,2
28,5
29,9

Material:
Clamp body:
1) Aluminium, forged
2) Casted Aluminium
Bolts, nuts:
1) M10, stainless steel
2) M12, h.d.g., alternatively stainless steel
Application:
See data-sheet B831
Remarks:
1) Recommended

tightening torque of bolts, M10: 46 Nm


Recommended tightening torque of bolts, M12: 60 Nm
The exact diameter of grooves A and B are needed when placing an order of parallel groove clamp acc. to RIBE-No. B 832 001.
Order example:
Groove A: 15,8 mm dia.
Groove B: 21,2 mm dia.
Parallel groove clamp: B 832 001/ A16 B27 Kb
For other executions please inquire.
Shunts: see data-sheet B833/1 and B833/2
2)

Stand: 18. Dezember 2009


Pfad: Optofit/ Earthing material/ Parallel groove clamps (with 3 bolts)/
Gedruckt am: 08. Januar 2010

66 / 117

ONLINE-CATALOGUE
B832/3 Parallel groove clamps (special design)

1 ..... Shunt (Al/St)


2 ..... OPGW
3 ..... Bolt M12
RIBE-Order-No.
F 5094-10/4
F 5094-10/6
F 5094-10/1
F 5094-10/7
F 5095-10/2
F 5095-10/1
F 5095-10/3
F 5038-18/3
F 5038-18/2
F 5038-18/1
F 5096-14
F 5096-18
F 5096-16
F 5098-15
F 5096-17
F 14 006-10/2
F 14 006-10/1
F 5038-17
F 5038-12
F 5038-14
F 5038-13
F 5038-11
F 5038-10
F 5096-13
F 5096-11/2
F 5096-10
F 5096-11/1
F 5096-11/3
F 5097-10
F 5097-13
F 5097-11
F 5098-10/1
F 5098-10/2
F 5098-10/3
F 5098-10/4
F 5098-10/5

Diameter of OPGW
mm
16,0 - 16,1
16,3
16,4 - 16,6
18,2
18,9 - 19,0
19,3 - 19,4
19,5 - 19,6
14,5
18,0
18,5
20,4
21,0
21,2
22,4 - 22,5
22,7
25,1
30,3
12,9
14,0
15,2 - 15,6
17,6
18,0
18,4 - 18,7
20,4
21,4
21,7 - 21,8
22,1 - 22,4
23,3 - 23,4
22,7 - 22,9
24,1
25,1 - 25,2
25,8
27,3
28,0
25,2
26,8

Stand: 07. Mai 2007


Pfad: Optofit/ Earthing material/ Parallel groove clamps (special design)/
Gedruckt am: 08. Januar 2010

Mass/ pcs
kg

Shunt

0,6

Al/St 95/55 mm - 16,0 mm

0,7

Al/St 185/30 mm - 19,0 mm

0,9
0,7

(Al/St 210/36 mm - 20,5 mm)


Al/St 210/35 mm - 20,3 mm

1,13
1,13
0,9

Al/St 265/35 mm - 22,4 mm


0,7

0,7

0,7

Al/St 265/35 mm - 22,4 mm


Al/St 265/35 mm - 22,4 mm
Al/St 265/35 mm - 22,4 mm
Al/St 340/30 mm - 25,0 mm
Al/St 265/35 mm - 22,4 mm

67 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
F 5098-10/6
F 5098-10/4

Diameter of OPGW
mm
24,6
25,2

Mass/ pcs
kg
0,7

Shunt
Al/St xxx/xx mm - 21,7 mm
Al/St 340/30 mm - 25,0 mm

Material:
Clamp body: Aluminium, forged
Bolts, nuts: h.d.g., alternatively stainless steel
Application:
See data-sheet B831
Remarks:
Recommended tightening torque of bolts, M12: 60 Nm
For other executions please inquire.
Shunts: see data-sheet B833/1 and B833/2

Stand: 07. Mai 2007


Pfad: Optofit/ Earthing material/ Parallel groove clamps (special design)/
Gedruckt am: 08. Januar 2010

68 / 117

ONLINE-CATALOGUE
B832/4 Earthing profil for fixing of OPGW with helical fittings

1 ..... Bolt M10/ 46 Nm/ W.a.f. 17


RIBE-Order-No.
Clamping range
D1
mm
B 832 006/1
8,80 - 10,09
B 832 006/2
10,10 - 11,49
B 832 006/3
11,50 - 13,10
B 832 006/4
13,11 - 14,81
B 832 006/5
14,82 - 16,62
B 832 006/6
16,63 - 18,53
B 832 006/7
18,54 - 20,54
B 832 006/8
20,55 - 22,60

RIBE-No.
TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052

L
mm
400
400
400
400
400
430
480
520

Helical rods
D2
mm
2,59
2,90
2,90
3,25
3,25
3,25
3,25
3,25

Mass/ pcs
No. of wires
3
3
3
3
3
3
3
3

H
mm
31,5
32,5
34,0
35,5
37,0
39,0
41,0
42,5

kg
0,17
0,17
0,17
0,18
0,18
0,19
0,20
0,20

Material:
Helical rods: Aluminium-clad steel
Clamp body: Aluminium
Threaded bolt, nut: Stainless steel A2-80
Washer: Stainless steel A2
Application:
The earthing profil consists of a clamp body and a set of helical rods, which fix the OPGW on the clamp body. The earthing profil is fixed on
the tower by means of a threaded bolt. The earthing profil is used to get a defined earthing and is safe from short current.
Remarks:
The exact diameter of cable is needed when placing an order of earthing profil acc. to RIBE-No. B 832 006.
Order example:
Cable: 15,8 mm dia.
Earthing profil: B 832 006/ A5
For other executions please inquire.

Stand: 15. Mai 2006


Pfad: Optofit/ Earthing material/ Earthing profil for fixing of OPGW with helical fittings/
Gedruckt am: 08. Januar 2010

69 / 117

ONLINE-CATALOGUE
B833/1 Shunts with ACSR-conductors

RIBE-Order-No.

F 10 835-10/1
F 10 835-10/2
F 10 835-10/3
F 10 837/1
F 10 837/2
F 10 837/3
F 10 833-10/2
F 10 833-10/3
F 10 833-10/5
F 10 833-10/6
F 10 833-10/7
F 10 833-10/8
F 10 833-10/10
F 10 833-10/1
F 10 833-10/9

Conductor

Al/St 150/25 mm - 17,1 mm

Al/St 185/30 mm - 19,0 mm


(Al/St 210/36 mm - 20,5 mm)
(Al/St 210/36 mm - 20,5 mm)
Al/St 210/35 mm - 20,3 mm

Al/St 265/35 mm - 22,4 mm

Dimensions
L
mm
1000
1000
2000
2000
1500
2500
1500
2000
1500
2500
2000
1000
1300
1000
2000

a
mm
10
10
10
9,7
9,7
9,7
12,0
12,0
12,0
12,0
12,0
12,0
12,0
10,5
10,5

b
mm
39,5
39,5
39,5
42,5
42,5
42,5
46,5
46,5
46,5
46,5
46,5
46,5
46,5
47,5
47,5

IK
c
mm
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50

15
30
30
15
15
15
15
15
15
15
15
15
15
15
15

kA
15,8

19,5

22,2

27,5

Material:
Cable lug: Aluminium alloy
Conductor: ACSR
Bolts, nuts: M12, h.d.g., alternatively stainless steel
Application:
See data-sheet B831
Installation:
Recommended tightening torque of Bolts M12: 80 Nm
Remarks:
The short current values IK are valid for a shunt with a current density of 100 A/mm (in the Al-Part) and heat the shunts up from the
starting temperature ? = 20 ? = 160.
For other executions please inquire.

Stand: 10. August 2006


Pfad: Optofit/ Earthing material/ Shunts with ACSR-conductors/
Gedruckt am: 08. Januar 2010

70 / 117

ONLINE-CATALOGUE
B833/2 Shunts with Al-conductors

Fig. 1

Fig. 2

Fig.

RIBE-Order-No.

1
1
1
1
1
1
1

F 10 828-52/1
F 10 828-52/2
F 10 828-52/3
F 10 828-52/4
F 10 828-52/5
F 10 828-52/6
F 10 830

1
1
1
1
2
2

F 3140-52/1
F 3140-52/2
F 3140-52/3
F 3140-52/4
F 3140-52/5
F 3140-52/6

Conductor

Dimensions

IK

mm
9
9
9
9
9
9
8

mm
30
30
30
30
30
30
32

mm
50
50
50
50
50
50
34

30
30
15
30
30
30
30

Al 120 mm - 14,0 mm

mm
1000
1300
1000
1500
1200
2000
1500

Al 120 mm - 14,0 mm

1000
1200
1500
2000
2000
2200

8
8
8
8
8
8

32
32
32
32
32
32

50
50
50
50
50
50

30
30
30
30
30
30

Al 95 mm - 12,5 mm

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with Al-conductors/
Gedruckt am: 08. Januar 2010

kA

9,1

11,4

30
30

11,4

71 / 117

ONLINE-CATALOGUE
Fig.

2
2
2
1
1
1

RIBE-Order-No.

Conductor

F 3140-52/7
F 3140-52/8
F 3140-52/9
F 3140-52/10
F 3140-52/11
F 3140-52/12

Dimensions

IK

mm
1200
1500
1800
1300
3000
2500

mm
8
8
8
8
8
8

mm
32
32
32
32
32
32

mm
50
50
50
50
50
50

30
30
30
30
30
30

30
30
30

kA

Material:
Cable lug: Aluminium alloy
Conductor: Al
Bolts, nuts: M12, h.d.g., alternatively stainless steel
Application:
See data-sheet B831
Installation:
Recommended tightening torque of Bolts M12: 80 Nm
Remarks:
The short current values IK are valid for a shunt with a current density of 100 A/mm and heat the shunts up from the starting
temperature ? = 20C to the end temperature ? = 160C.
For other executions please inquire.

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with Al-conductors/
Gedruckt am: 08. Januar 2010

72 / 117

ONLINE-CATALOGUE
B833/4 Earth bonds for OPGW with helical attachment, aluminium earthing conductor and
cable lug

1 ..... Contact piece


2 ..... Attachment rods
Exe. x

1
2
3
4
5
6
7
8

D1
mm
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,60

Earth bond with helical attachment B 831 001/Ax Ly


Helical rods
RIBE-Order-No.
No. of rods
D2
mm
TW 100 040
3
2,59
TW 114 040
3
2,90
TW 131 040
3
2,90
TW 148 040
3
3,25
TW 166 040
3
3,25
TW 185 043
3
3,25
TW 205 048
3
3,25
TW 225 052
3
3,25

H
L1
mm
400
400
400
400
400
430
480
520

mm
35,0
36,0
37,5
39,0
40,5
42,5
44,5
46,0

Earthing conductor
Description

Al 95 mm
Ik = 9,1 kA

D3
mm

12,5

Length of shunt L
L3 / mm

Exe. y
1
2
3
4
5

Exe. x

D1

1000
2000
1500
3000
2400
Earth bond with helical attachment B 831 002/Ax Ly
Helical rods
RIBE-No.
No. of rods
D2
L1

Stand: 31. Juli 2007


Pfad: Optofit/ Earthing material/ Earth bonds for OPGW with helical attachment, aluminium earthing conductor and cable lug/
Gedruckt am: 08. Januar 2010

Earthing conductor
Description

D3

73 / 117

ONLINE-CATALOGUE
1
2
3
4
5
6
7
8

mm
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,60

TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052

3
3
3
3
3
3
3
3

mm
2,59
2,90
2,90
3,25
3,25
3,25
3,25
3,25

mm
400
400
400
400
400
430
480
520

mm
35,0
36,0
37,5
39,0
40,5
42,5
44,5
46,0

mm

Al 120 mm
IK = 11,4 kA

14,0

Material:
Contact piece: Aluminium alloy
Cable lug: Aluminium alloy
Earthing conductor: Al
Bolt, nut: M16, h.d.g., alternatively stainless steel
Helical attachment rods: Aluminium-clad steel
Installation:
Recommended tightening torque of Bolt M16: 190 Nm
Remarks:
Short-circuit current ratings are based on a short-circuit current IK for 1 s with a current density of 100 A/mm (initial temperature ? = 20
C, final temperature ? = 160C).
Order example:
OPGW-Diameter: 13,5 mm
Conductor: Al 95 mm - 12,5 mm
Length of conductor: 2000 mm
RIBE-Order-No.: B 831 001/A4 L2
For other sizes please inquire.

Stand: 31. Juli 2007


Pfad: Optofit/ Earthing material/ Earth bonds for OPGW with helical attachment, aluminium earthing conductor and cable lug/
Gedruckt am: 08. Januar 2010

74 / 117

ONLINE-CATALOGUE
B834/1 Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on
tower side with 2 holes)

Fig.: Mounting example

1 ..... Cable lug A


2 ..... Cable lug B
Material:
Cable lug, flexible shunt: Electrolytic copper, tinned
Application:
To thermically relieve the hinges of the suspension clamps in case of a short-circuit, we recommend shunts. Dependent on short-circuit
value one or two shunts are installed. They connect the two halves of the clamp to the tower.
Remarks:
Bolt sets for fixing the shunts to the tower are not included. If required, they have to be ordered separately (e.g. bolt M 12x55 grade 8.8
including nut and 2 washers; bolts and nuts hot dipped galvanized; stainless steel washers).
On request shunts can be delivered with shrinkdown plastic tubing (order example: 60500a).
The short-circuit values Ith are valid for a shunt with a current density of 150 A/mm and heat the shunts up from the starting
temperature ? = 20C to the end temperature ? = 160C.
Amor grip suspensions: see data-sheet B801/2 and B801/4
For other executions please inquire.

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on tower side with 2 holes)/
Gedruckt am: 08. Januar 2010

75 / 117

ONLINE-CATALOGUE
RIBE-Order-No..

60500

60501

60502

60503
oder
60504

For armour grip suspension

LTA 104 .../7


LTA 111 .../8
LTA 118 .../13
LTA 125 .../14
LTA 131 .../15
LTA 137 .../16
LTA 144 .../6
LTA 149 .../7
LTA 157 .../8
LTA 161 .../9
LTA 165 .../10
LTA 172 .../5
LTA 179 .../6
LTA 186 .../7
LTA 193 .../8
LTA 203 .../9
LTA 213 .../10
LTA 222 .../11
LTA 231 .../12
LTA 237 .../5
LTA 243 .../6
LTA 249 .../7
LTA 256 .../8
LTA 265 .../7
LTA 274 .../8
LTA 283 .../9
LTA 292 .../10
LTA 299 .../11
LTA 306 .../12
LTA 311 .../6
LTA 317 .../7
LTA 326 .../8
LTA 333 .../9
LTA 344 .../10
LTA 203 .../5
LTA 213 .../6
LTA 222 .../7
LTA 231 .../8
LTA 237 .../9
LTA 243 .../10
LTA 249 .../11
LTA 256 .../12
LTA 265 .../13
LTA 274 .../14
LTA 283 .../15
LTA 292 .../16
LTA 299 .../17
LTA 306 .../18
LTA 311 .../11
LTA 317 .../12
LTA 326 .../13
LTA 333 .../14
LTA 344 .../15

Flex. shunt
Ith
Dia.
mm
kA

Mass/
pcs
kg

a
mm

b
mm

c
mm

L
mm

A
mm

25

35-42

8,4

850

35

9,0

5,5

0,4

25

35-42

8,4

850

50

10,5

7,5

0,52

30

35-42

10,5

850

50

10,5

7,5

0,54

30

35-42
oder
50

11

850

70

13,0

10,7

0,78

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with flexible Cu-conductors for armour grip suspensions (cable lug on tower side with 2 holes)/
Gedruckt am: 08. Januar 2010

76 / 117

ONLINE-CATALOGUE
B834/2 Shunts with Al-conductors for armour grip suspensions (cable lug on tower side
with 1 hole)

Fig.: Mounting example

1 ..... Cable lug A


2 ..... Cable lug B
Material:
Cable lug, flexible shunt: Electrolytic copper, tinned
Application:
To thermically relieve the hinges of the suspension clamps in case of a short-circuit, we recommend shunts. Dependent on short-circuit
value one or two shunts are installed. They connect the two halves of the clamp to the tower.
Remarks:
Bolt sets for fixing the shunts to the tower are not included. If required, they have to be ordered separately (e.g. bolt M 16x55 grade 8.8
including nut and 2 washers; bolts and nuts hot dipped galvanized; stainless steel washers).
On request shunts can be delivered with shrinkdown plastic tubing (order example: F 10 821/1a).
The short-circuit values Ith are valid for a shunt with a current density of 150 A/mm and heat the shunts up from the starting
temperature ? = 20C to the end temperature ? = 160C.
Amor grip suspensions: see data-sheet B801/2 and B801/4
For other executions please inquire.
RIBE-Order-No..

For armour grip suspension


a
mm

c
mm

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with Al-conductors for armour grip suspensions (cable lug on tower side with 1 hole)/
Gedruckt am: 08. Januar 2010

L
mm

A
mm

Flex. shunt
Ith
Dia.
mm
kA

Mass/
pcs
kg

77 / 117

ONLINE-CATALOGUE
RIBE-Order-No..

For armour grip suspension

F 10 821/1

F 10 821/2

F 10 821/3

F 10 821/4

LTA 104 .../7


LTA 111 .../8
LTA 118 .../13
LTA 125 .../14
LTA 131 .../15
LTA 137 .../16
LTA 144 .../6
LTA 149 .../7
LTA 157 .../8
LTA 161 .../9
LTA 165 .../10
LTA 172 .../5
LTA 179 .../6
LTA 186 .../7
LTA 193 .../8
LTA 203 .../9
LTA 213 .../10
LTA 222 .../11
LTA 231 .../12
LTA 237 .../5
LTA 243 .../6
LTA 249 .../7
LTA 256 .../8
LTA 265 .../7
LTA 274 .../8
LTA 283 .../9
LTA 292 .../10
LTA 299 .../11
LTA 306 .../12
LTA 311 .../6
LTA 317 .../7
LTA 326 .../8
LTA 333 .../9
LTA 344 .../10
LTA 203 .../5
LTA 213 .../6
LTA 222 .../7
LTA 231 .../8
LTA 237 .../9
LTA 243 .../10
LTA 249 .../11
LTA 256 .../12
LTA 265 .../13
LTA 274 .../14
LTA 283 .../15
LTA 292 .../16
LTA 299 .../17
LTA 306 .../18
LTA 311 .../11
LTA 317 .../12
LTA 326 .../13
LTA 333 .../14
LTA 344 .../15

Flex. shunt
Ith
Dia.
mm
kA

Mass/
pcs
kg

a
mm

c
mm

L
mm

A
mm

25

8,4

850

35

9,0

5,5

0,4

25

8,4

850

50

10,5

7,5

0,52

30

10,5

850

50

10,5

7,5

0,54

30

11

850

70

13,0

10,7

0,78

Stand: 04. Mai 2007


Pfad: Optofit/ Earthing material/ Shunts with Al-conductors for armour grip suspensions (cable lug on tower side with 1 hole)/
Gedruckt am: 08. Januar 2010

78 / 117

ONLINE-CATALOGUE
B841/1 Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers

1 ..... Optical fibre aerial cable


2 ..... Optical fibre aerial cable or filler bolt
3 ..... Tower
Clamping range

RIBE-Order-No.

mm
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5

F 11 060-20/32
F 11 060-20/33
F 11 060-20/01
F 11 060-20/02
F 11 060-20/03
F 11 060-20/04
F 11 060-20/05

Mass/
pcs
kg

RIBE-No. for Filler


bolt
F 11 060-02/32
F 11 060-02/33
F 11 060-02/01
F 11 060-02/02
F 11 060-02/03
F 11 060-02/04
F 11 060-02/05

Clamping range

RIBE-Order-No.

mm
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5
22,51 - 23,0

F 11 060-20/20
F 11 060-20/21
F 11 060-20/22
F 11 060-20/23
F 11 060-20/24
F 11 060-20/25
F 11 060-20/26

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

Mass/
pcs
kg

0,8

RIBE-No. for Filler


bolt
F 11 060-02/20
F 11 060-02/21
F 11 060-02/22
F 11 060-02/23
F 11 060-02/24
F 11 060-02/25
F 11 060-02/26

79 / 117

ONLINE-CATALOGUE
Clamping range

RIBE-Order-No.

mm
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5

F 11 060-20/06
F 11 060-20/07
F 11 060-20/08
F 11 060-20/09
F 11 060-20/10
F 11 060-20/11
F 11 060-20/12
F 11 060-20/13
F 11 060-20/14
F 11 060-20/15
F 11 060-20/16
F 11 060-20/17
F 11 060-20/18
F 11 060-20/19

Mass/
pcs
kg
0,8

RIBE-No. for Filler


bolt
F 11 060-02/06
F 11 060-02/07
F 11 060-02/08
F 11 060-02/09
F 11 060-02/10
F 11 060-02/11
F 11 060-02/12
F 11 060-02/13
F 11 060-02/14
F 11 060-02/15
F 11 060-02/16
F 11 060-02/17
F 11 060-02/18
F 11 060-02/19

Clamping range

RIBE-Order-No.

mm
23,01 - 23,5
23,51 - 24,0
24,01 - 24,5
24,51 - 25,0
25,01 - 25,5
25,51 - 26,0
26,01 - 26,5
26,51 - 27,0
27,01 - 27,5
27,51 - 28,0
28,01 - 28,5
28,51 - 29,0
29,01 - 29,5
29,51 - 30,0

F 11 060-20/27
F 11 060-20/28
F 11 060-20/29
F 11 060-20/30
F 11 060-20/31
F 11 060-30/01
F 11 060-30/02
F 11 060-30/03
F 11 060-30/04
F 11 060-30/05
F 11 060-30/06
F 11 060-30/07
F 11 060-30/08
F 11 060-30/09

Mass/
pcs
kg

0,8

RIBE-No. for Filler


bolt
F 11 060-02/27
F 11 060-02/28
F 11 060-02/29
F 11 060-02/30
F 11 060-02/31
F 11 060-02/34
F 11 060-02/35
F 11 060-02/36
F 11 060-02/37
F 11 060-02/38
F 11 060-02/39
F 11 060-02/40
F 11 060-02/41
F 11 060-02/42

Material:
Clamp: Aluminium alloy, forged
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
Insert filler bolt acc. to drawing No. F 11060-02/index in second groove if only one cable is led down the tower.
By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible.
Installation:
Recommended tightening torque for clamp: 30 Nm
Recommended tightening torque for U-bracket: 15 Nm
Remarks:
Filler bolts: see data-sheet B845
For other executions please inquire.

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 200 mm) for optical aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

80 / 117

ONLINE-CATALOGUE
B841/2 Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers

1 ..... Optical fibre aerial cable


2 ..... Optical fibre aerial cable or filler bolt
3 ..... Tower
Clamping range

RIBE-Order-No.

mm
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5

F 11 060-50/32
F 11 060-50/33
F 11 060-50/01
F 11 060-50/02
F 11 060-50/03
F 11 060-50/04
F 11 060-50/05

Mass/
pcs
kg

RIBE-No. for
Fillerbolt
F 11 060-02/32
F 11 060-02/33
F 11 060-02/01
F 11 060-02/02
F 11 060-02/03
F 11 060-02/04
F 11 060-02/05

Clamping range

RIBE-Order-No.

mm
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0

F 11 060-50/16
F 11 060-50/17
F 11 060-50/18
F 11 060-50/19
F 11 060-50/20
F 11 060-50/21
F 11 060-50/22

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

Mass/
pcs
kg

RIBE-No. for
Fillerbolt
F 11 060-02/16
F 11 060-02/17
F 11 060-02/18
F 11 060-02/19
F 11 060-02/20
F 11 060-02/21
F 11 060-02/22

81 / 117

ONLINE-CATALOGUE
Clamping range

RIBE-Order-No.

mm
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5

F 11 060-50/06
F 11 060-50/07
F 11 060-50/08
F 11 060-50/09
F 11 060-50/10
F 11 060-50/11
F 11 060-50/12
F 11 060-50/13
F 11 060-50/14
F 11 060-50/15

Mass/
pcs
kg
0,8

RIBE-No. for
Fillerbolt
F 11 060-02/06
F 11 060-02/07
F 11 060-02/08
F 11 060-02/09
F 11 060-02/10
F 11 060-02/11
F 11 060-02/12
F 11 060-02/13
F 11 060-02/14
F 11 060-02/15

Clamping range

RIBE-Order-No.

mm
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5
22,51 - 23,0
23,01 - 23,5
23,51 - 24,0
24,01 - 24,5
24,51 - 25,0
25,01 - 25,5

F 11 060-50/23
F 11 060-50/24
F 11 060-50/25
F 11 060-50/26
F 11 060-50/27
F 11 060-50/28
F 11 060-50/29
F 11 060-50/30
F 11 060-50/31

Mass/
pcs
kg
0,8

RIBE-No. for
Fillerbolt
F 11 060-02/23
F 11 060-02/24
F 11 060-02/25
F 11 060-02/26
F 11 060-02/27
F 11 060-02/28
F 11 060-02/29
F 11 060-02/30
F 11 060-02/31

Material:
Clamp: Aluminium alloy, forged
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
Insert filler bolt acc. to drawing No. F 11060-02/index in second groove if only one cable is led down the tower.
By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible.
Installation:
Recommended tightening torque for clamp: 30 Nm
Recommended tightening torque for U-bracket: 15 Nm
Remarks:
Filler bolts: see data-sheet B845
For other executions please inquire.

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps (height = 250 mm) for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

82 / 117

ONLINE-CATALOGUE
B841/3 Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or
wood

1 ..... Optical fibre aerial cable


2 ..... Optical fibre aerial cable or filler bolt
3 ..... Fixing clip
4 ..... Steel tape
5 ..... Fixing clip for steel tape attachment
6 ..... Tower
Clamping range
mm
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5

RIBE-Order-No.

B 841 003/32
B 841 003/33
B 841 003/01
B 841 003/02
B 841 003/03
B 841 003/04
B 841 003/05
B 841 003/06
B 841 003/07
B 841 003/08
B 841 003/09
B 841 003/10
B 841 003/11

Mass/
pcs
kg

0,46

RIBE-No. for
Fillerbolt
F 11 060-02/32
F 11 060-02/33
F 11 060-02/01
F 11 060-02/02
F 11 060-02/03
F 11 060-02/04
F 11 060-02/05
F 11 060-02/06
F 11 060-02/07
F 11 060-02/08
F 11 060-02/09
F 11 060-02/10
F 11 060-02/11

Clamping range
mm
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5
22,51 - 23,0
23,01 - 23,5
23,51 - 24,0
24,01 - 24,5
24,51 - 25,0
25,01 - 25,5
25,51 - 26,0

RIBE-Order-No.

B 841 003/20
B 841 003/21
B 841 003/22
B 841 003/23
B 841 003/24
B 841 003/25
B 841 003/26
B 841 003/27
B 841 003/28
B 841 003/29
B 841 003/30
B 841 003/31
B 841 003/34

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or wood /
Gedruckt am: 08. Januar 2010

Mass/
pcs
kg

0,46

RIBE-No. for
Fillerbolt
F 11 060-02/20
F 11 060-02/21
F 11 060-02/22
F 11 060-02/23
F 11 060-02/24
F 11 060-02/25
F 11 060-02/26
F 11 060-02/27
F 11 060-02/28
F 11 060-02/29
F 11 060-02/30
F 11 060-02/31
F 11 060-02/34

83 / 117

ONLINE-CATALOGUE
Clamping range
mm
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5

RIBE-Order-No.

Mass/
pcs
kg

B 841 003/12
B 841 003/13
B 841 003/14
B 841 003/15
B 841 003/16
B 841 003/17
B 841 003/18
B 841 003/19

RIBE-No. for
Fillerbolt
F 11 060-02/12
F 11 060-02/13
F 11 060-02/14
F 11 060-02/15
F 11 060-02/16
F 11 060-02/17
F 11 060-02/18
F 11 060-02/19

Part name
Steel tape
Fixing clip

Clamping range
mm
26,01 - 26,5
26,51 - 27,0
27,01 - 27,5
27,51 - 28,0
28,01 - 28,5
28,51 - 29,0
29,01 - 29,5
29,51 - 30,0

RIBE-Order-No.

B 841 003/35
B 841 003/36
B 841 003/37
B 841 003/38
B 841 003/39
B 841 003/40
B 841 003/41
B 841 003/42

RIBE-Order-No.
B 841 003 T7
B 841 003 T8

Mass/
pcs
kg

RIBE-No. for
Fillerbolt
F 11 060-02/35
F 11 060-02/36
F 11 060-02/37
F 11 060-02/38
F 11 060-02/39
F 11 060-02/40
F 11 060-02/41
F 11 060-02/42

Remark
to be ordered separately
to be ordered separately

Material:
Clamp: Aluminium alloy, forged
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Fixing clip: Steel, h.d.g.
Steel tape: Stainless steel
Fixing clip: Stainless steel
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the consisting of steel, concrete, or wood to
the joint box.
Insert filler bolt acc. to drawing No. F 11060-02/index in second groove if only one cable is led down the tower.
Installation:
Recommended tightening torque for clamp: 30 Nm
Remarks:
Filler bolts: see data-sheet B845
For other executions please inquire.

Stand: 31. Juli 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at towers with steel rod, concrete or wood /
Gedruckt am: 08. Januar 2010

84 / 117

ONLINE-CATALOGUE
B841/5 Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice
towers

1 ..... Groove A
2 ..... Groove B
3 ..... Tower
RIBE-Order-No.
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/

Exe.
1
2
3
4
5
6
7

Clamping range of groove A


mm
9,00
9,51
10,01
10,51
11,01
11,51
12,01
-

9,5
10,0
10,5
11,0
11,5
12,0
12,5

Exe.
1
2
3
4
5
6
7

Clamping range of groove B


mm
9,00
9,51
10,01
10,51
11,01
11,51
12,01
-

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

Mass/ pcs
kg
9,5
10,0
10,5
11,0
11,5
12,0
12,5

85 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/
B 841 002/

Exe.
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Clamping range of groove A


mm
12,51
13,01
13,51
14,01
14,51
15,01
15,51
16,01
16,51
17,01
17,51
18,01
18,51
19,01
19,51
20,01
20,51
21,01
21,51
22,01
22,51
23,01
23,51
24,01
24,51
25,01
25,51
26,01
26,51
27,01
27,51
28,01
28,51
29,01
29,51
-

13,0
13,5
14,0
14,5
15,0
15,5
16,0
16,5
17,0
17,5
18,0
18,5
19,0
19,5
20,0
20,5
21,0
21,5
22,0
22,5
23,0
23,5
24,0
24,5
25,0
25,5
26,0
26,5
27,0
27,5
28,0
28,5
29,0
29,5
30,0

Exe.
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Clamping range of groove B


mm
12,51
13,01
13,51
14,01
14,51
15,01
15,51
16,01
16,51
17,01
17,51
18,01
18,51
19,01
19,51
20,01
20,51
21,01
21,51
22,01
22,51
23,01
23,51
24,01
24,51
25,01
25,51
26,01
26,51
27,01
27,51
28,01
28,51
29,01
29,51
-

Mass/ pcs
kg
13,0
13,5
14,0
14,5
15,0
15,5
16,0
16,5
17,0
17,5
18,0
18,5
19,0
19,5
20,0
20,5
21,0
21,5
22,0
22,5
23,0
23,5
24,0
24,5
25,0
25,5
26,0
26,5
27,0
27,5
28,0
28,5
29,0
29,5
30,0

0,8

Material:
Clamp: Aluminium alloy, forged
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible.
Installation:
Recommended tightening torque for clamp: 30 Nm
Recommended tightening torque for U-bracket: 15 Nm
Remarks:

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

86 / 117

ONLINE-CATALOGUE
The exact diameter of grooves A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 841 002.
Order example:
Groove A: 15,8 mm dia.
Groove B: 21,2 mm dia.
Fixing clamp: B 841 002/ A14 B25

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

87 / 117

ONLINE-CATALOGUE
B841/7 Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice
towers

1 ..... Groove A
2 ..... Groove B
3 ..... Tower
RIBE-Order-No.
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/

Exe.
1
2
3
4
5
6
7

Clamping range of groove A


mm
9,00
9,51
10,01
10,51
11,01
11,51
12,01
-

9,5
10,0
10,5
11,0
11,5
12,0
12,5

Exe.
1
2
3
4
5
6
7

Clamping range of groove B


Mm
9,00
9,51
10,01
10,51
11,01
11,51
12,01
-

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

Mass/ pcs

9,5
10,0
10,5
11,0
11,5
12,0
12,5

88 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/
B 841 002-20/

Exe.
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Clamping range of groove A


mm
12,51
13,01
13,51
14,01
14,51
15,01
15,51
16,01
16,51
17,01
17,51
18,01
18,51
19,01
19,51
20,01
20,51
21,01
21,51
22,01
22,51
23,01
23,51
24,01
24,51
25,01
25,51
26,01
26,51
27,01
27,51
28,01
28,51
29,01
29,51
-

13,0
13,5
14,0
14,5
15,0
15,5
16,0
16,5
17,0
17,5
18,0
18,5
19,0
19,5
20,0
20,5
21,0
21,5
22,0
22,5
23,0
23,5
24,0
24,5
25,0
25,5
26,0
26,5
27,0
27,5
28,0
28,5
29,0
29,5
30,0

Exe.
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Clamping range of groove B


Mm
12,51
13,01
13,51
14,01
14,51
15,01
15,51
16,01
16,51
17,01
17,51
18,01
18,51
19,01
19,51
20,01
20,51
21,01
21,51
22,01
22,51
23,01
23,51
24,01
24,51
25,01
25,51
26,01
26,51
27,01
27,51
28,01
28,51
29,01
29,51
-

Mass/ pcs

13,0
13,5
14,0
14,5
15,0
15,5
16,0
16,5
17,0
17,5
18,0
18,5
19,0
19,5
20,0
20,5
21,0
21,5
22,0
22,5
23,0
23,5
24,0
24,5
25,0
25,5
26,0
26,5
27,0
27,5
28,0
28,5
29,0
29,5
30,0

0,8

Material:
Clamp: Aluminium alloy, forged
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible.
Installation:
Recommended tightening torque for clamp: 30 Nm
Recommended tightening torque for U-bracket: 15 Nm
Remarks:

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

89 / 117

ONLINE-CATALOGUE
The exact diameter of grooves A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 841 002-20.
Order example:
Groove A: 15,8 mm dia.
Groove B: 21,2 mm dia.
Fixing clamp: B 841 002-20/ A14 B25

Stand: 20. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with 2 different grooves for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

90 / 117

ONLINE-CATALOGUE
B841/8 Fixing clamps for optical fibre aerial cables at lattice towers

RIBE-Order-No.
Fig. 1
B 841 006/1
B 841 006/2
B 841 006/3
B 841 006/4
B 841 006/5

Fig. 2
B 841 006-40/1
B 841 006-40/2
B 841 006-40/3
B 841 006-40/4
B 841 006-40/5

Clamping range D
mm
8,00 - 10,00
10,01 - 12,50
12,51 - 15,50
15,51 - 19,50
19,51 - 25,00

A
mm
32
35
38
42
47

Mass/ pcs
kg

0,5

Material:
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Clip: Stainless steel
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
Insert filler bolt acc. to drawing No. F 11060-02/index in second groove if only one cable is led down the tower.
By a 90 turn of the U-bracket a turned fixing is possible.
Installation:
Recommended tightening torque for U-bracket: 15 Nm
Remarks:
Filler bolts: see data-sheet B845
For other executions please inquire.

Stand: 27. Februar 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps for optical fibre aerial cables at lattice towers/
Gedruckt am: 08. Januar 2010

91 / 117

ONLINE-CATALOGUE
B844/1 Fixing clamps with helical fittings

1 ..... RIBE-Order-No. B 844 001-10/Ax Bx


2 ..... RIBE-Order-No. B 844 001-15/Ax Bx
3 ..... RIBE-Order-No. B 844 001-20/Ax Bx
4 ..... Cable A
5 ..... Cable B
6 ..... MA = 23 Nm/ W.a.f. 13
7 ..... W.a.f. 13
8 ..... MA = 15 Nm/ W.a.f. 13
RIBE-Order-No. B 844 001-10/Ax Bx or B 844 001-15/Ax Bx or B 844 001-20/Ax Bx
Cable A
Cable B
Exe.
Clamping range
Exe.
Clamping range
mm
mm
9
7,00 - 7,90
9
7,00 - 7,90
10
7,91 - 8,79
10
7,91 - 8,79
1
8,80 - 10,09
1
8,80 - 10,09
2
10,10 - 11,49
2
10,10 - 11,49
3
11,50 - 13,10
3
11,50 - 13,10
4
13,11 - 14,81
4
13,11 - 14,81
5
14,82 - 16,62
5
14,82 - 16,62
6
16,63 - 18,53
6
16,63 - 18,53
7
18,54 - 20,54
7
18,54 - 20,54
8
20,55 - 22,55
8
20,55 - 22,55
11
22,56 - 24,50
11
22,56 - 24,50

RIBE-No.
TW 079 031
TW 087 034
TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052
TW 245 052

Helical rods
L
Dia.
mm
mm
312
2,59
340
2,59
400
2,59
400
2,90
400
2,90
400
3,25
400
3,25
430
3,25
480
3,25
520
3,25
520
3,25

No. of wires

Mass/
pcs
kg

0,4

Material:
Helical rods: Aluminium-clad steel
U-bracket: Steel, h.d.g.
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the lattice tower to the joint box.
By a 90 turn of the U-bracket a turned fixing according to fig. 2 is possible.
Remarks:
The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 844 001-10 or B 844 001-15
or B 844 001-20.

Stand: 13. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings/
Gedruckt am: 08. Januar 2010

92 / 117

ONLINE-CATALOGUE
Order example:
Cable A: 15,8 mm dia.
Cable B: 21,2 mm dia.
Fixing clamp: B 844 001-10/ A5 B8 or B 844 001-15/ A5 B8 or B 844 001-20/ A5 B8
For other executions please inquire.

Stand: 13. Mrz 2007


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings/
Gedruckt am: 08. Januar 2010

93 / 117

ONLINE-CATALOGUE
B844/2 Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers
with steel ods, concrete or wood

1 ..... Cable A
2 ..... Cable B
3 ..... Fixing clip
4 ..... Steel tape
5 ..... Fixing clip for steel tape attachment
6 ..... MA = 23 Nm/ W.a.f. 13
7 ..... Tower
RIBE-Order-No. B 844 002/AX BX
Cable A
Exe.
Clamping range
mm
9
7,00 - 7,90
10
7,91 - 8,79
1
8,80 - 10,09
2
10,10 - 11,49
3
11,50 - 13,10
4
13,11 - 14,81
5
14,82 - 16,62
6
16,63 - 18,53
7
18,54 - 20,54
8
20,55 - 22,55
11
22,56 - 24,50
Part name
Steel tape
Fixing clip

Exe.
9
10
1
2
3
4
5
6
7
8
11

Cable B
Clamping range
mm
7,00 - 7,90
7,91 - 8,79
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,55
22,56 - 24,50
RIBE-Order-No.
B 841 003 T7
B 841 003 T8

RIBE-No.
TW 079 031
TW 087 034
TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052
TW 245 052

Helical rods
L
Dia.
mm
mm
312
2,59
340
2,59
400
2,59
400
2,90
400
2,90
400
3,25
400
3,25
430
3,25
480
3,25
520
3,25
520
3,25

No. of wires

Mass/
pcs
kg

0,4

Remark
to be ordered separately
to be ordered separately

Material:
Helical rods: Aluminium-clad steel
U-bracket: Steel, h.d.g.

Stand: 15. Mai 2006


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers with steel ods, concrete or wood/
Gedruckt am: 08. Januar 2010

94 / 117

ONLINE-CATALOGUE
Threaded bolt, nuts: Stainless steel A2-70
Bolt: Stainless steel A2-80
Fixing clip: Steel, h.d.g.
Steel tape: Stainless steel
Fixing clip: Stainless steel
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the tower consisting of steel rod, concrete or
wood to the joint box.
Remarks:
The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 844 002.
Order example:
Cable A: 15,8 mm dia.
Cable B: 21,2 mm dia.
Fixing clamp: B 844 002/A5 B8
For other executions please inquire.

Stand: 15. Mai 2006


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at rounded towers with steel ods, concrete or wood/
Gedruckt am: 08. Januar 2010

95 / 117

ONLINE-CATALOGUE
B844/3 Fixing clamps with helical fittings for optical fibre aerial cables at wooden poles

1 ..... Cable A
2 ..... Cable B
3 ..... W.a.f. 12
RIBE-Order-No. B 844 003/AX BX
Cable A
Exe.
Clamping range
mm
1
7,00 - 7,90
2
7,91 - 8,79
3
8,80 - 10,09
4
10,10 - 11,49
5
11,50 - 13,10
6
13,11 - 14,81
7
14,82 - 16,62
8
16,63 - 18,53
9
18,54 - 20,54
10
20,55 - 22,55
11
22,56 - 24,50

Exe.
1
2
3
4
5
6
7
8
9
10
11

Cable B
Clamping range
mm
7,00 - 7,90
7,91 - 8,79
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,55
22,56 - 24,50

RIBE-No.
TW 079 031
TW 087 034
TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052
TW 245 052

Helical rods
L
Dia.
mm
mm
312
2,59
340
2,59
400
2,59
400
2,90
400
2,90
400
3,25
400
3,25
430
3,25
480
3,25
520
3,25
520
3,25

No. of wires

Mass/
pcs
kg

0,4

Material:
Helical rods: Aluminium-clad steel
U-bracket: Steel, h.d.g.
Washers: Stainless steel A2
Hexagonal bolt: Steel, h.d.g.
Distance tube: Aluminium
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the wooden poles to the joint box.
Remarks:
The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 844 003.
Order example:
Cable A: 15,8 mm dia.
Cable B: 21,2 mm dia.

Stand: 24. Juli 2008


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at wooden poles/
Gedruckt am: 08. Januar 2010

96 / 117

ONLINE-CATALOGUE
Fixing clamp: B 844 003/A7 B10
For other executions please inquire.

Stand: 24. Juli 2008


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings for optical fibre aerial cables at wooden poles/
Gedruckt am: 08. Januar 2010

97 / 117

ONLINE-CATALOGUE
B844/5 Fixing clamps with helical fittings at lattice towers

1 ..... Cable A
2 ..... Cable B
3 ..... MA = 23 Nm/ W.a.f. 13
RIBE-Order-No. B 844 001-30/AX BX
Cable A
Exe.
Clamping range
mm
1
7,00 - 7,90
2
7,91 - 8,79
3
8,80 - 10,09
4
10,10 - 11,49
5
11,50 - 13,10
6
13,11 - 14,81
7
14,82 - 16,62
8
16,63 - 18,53
9
18,54 - 20,54
10
20,55 - 22,55
11
22,56 - 24,50

Exe.
1
2
3
4
5
6
7
8
9
10
11

Cable B
Clamping range
mm
7,00 - 7,90
7,91 - 8,79
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,55
22,56 - 24,50

RIBE-No.
TW 079 031
TW 087 034
TW 100 040
TW 114 040
TW 131 040
TW 148 040
TW 166 040
TW 185 043
TW 205 048
TW 225 052
TW 245 052

Helical rods
L
Dia.
mm
mm
312
2,59
340
2,59
400
2,59
400
2,90
400
2,90
400
3,25
400
3,25
430
3,25
480
3,25
520
3,25
520
3,25

No. of wires

Mass/
pcs
kg

0,4

Material:
Helical rods: Aluminium-clad steel
Nuts: Stainless steel A2-80
Bolt: Stainless steel A2-80
Washers: Stainless steel
Application:
These clamps serve as fixing of the optical fibre aerial cable and guiding the cable down the tower consisting of steel to the joint box.
Remarks:
The exact diameter of cable A and B are needed when placing an order of fixing clamp acc. to RIBE-No. B 844 001-30.
Order example:
Cable A: 15,8 mm dia.
Cable B: 21,2 mm dia.
Fixing clamp: B 844 001-30/A5 B8
For other executions please inquire.

Stand: 15. Mai 2006


Pfad: Optofit/ Fixing clamps for tower attachment/ Fixing clamps with helical fittings at lattice towers/
Gedruckt am: 08. Januar 2010

98 / 117

ONLINE-CATALOGUE
B845 Filler bolts for fixing clamps

Clamping range
mm
9,01 - 9,5
9,51 - 10,0
10,01 - 10,5
10,51 - 11,0
11,01 - 11,5
11,51 - 12,0
12,01 - 12,5
12,51 - 13,0
13,01 - 13,5
13,51 - 14,0
14,01 - 14,5
14,51 - 15,0
15,01 - 15,5
15,51 - 16,0
16,01 - 16,5
16,51 - 17,0
17,01 - 17,5
17,51 - 18,0
18,01 - 18,5
18,51 - 19,0
19,01 - 19,5

RIBE-Order-No.
F 11 060-02/32
F 11 060-02/33
F 11 060-02/01
F 11 060-02/02
F 11 060-02/03
F 11 060-02/04
F 11 060-02/05
F 11 060-02/06
F 11 060-02/07
F 11 060-02/08
F 11 060-02/09
F 11 060-02/10
F 11 060-02/11
F 11 060-02/12
F 11 060-02/13
F 11 060-02/14
F 11 060-02/15
F 11 060-02/16
F 11 060-02/17
F 11 060-02/18
F 11 060-02/19

d
mm
8,9
9,4
9,9
10,4
10,9
11,4
11,9
12,4
12,9
13,4
13,9
14,4
14,9
15,4
15,9
16,4
16,9
17,4
17,9
18,4
18,9

Mass/ pcs
kg
0,017
0,017
0,019
0,019
0,020
0,020
0,021
0,021
0,022
0,022
0,023
0,023
0,024
0,024
0,027
0,028
0,030
0,032
0,032
0,035
0,035

Clamping range
mm
19,51 - 20,0
20,01 - 20,5
20,51 - 21,0
21,01 - 21,5
21,51 - 22,0
22,01 - 22,5
22,51 - 23,0
23,01 - 23,5
23,51 - 24,0
24,01 - 24,5
24,51 - 25,0
25,01 - 25,5
25,51 - 26,0
26,01 - 26,5
26,51 - 27,0
27,01 - 27,5
27,51 - 28,0
28,01 - 28,5
28,51 - 29,0
29,01 - 29,5
29,51 - 30,0

RIBE-Order-No.
F 11 060-02/20
F 11 060-02/21
F 11 060-02/22
F 11 060-02/23
F 11 060-02/24
F 11 060-02/25
F 11 060-02/26
F 11 060-02/27
F 11 060-02/28
F 11 060-02/29
F 11 060-02/30
F 11 060-02/31
F 11 060-02/34
F 11 060-02/35
F 11 060-02/36
F 11 060-02/37
F 11 060-02/38
F 11 060-02/39
F 11 060-02/40
F 11 060-02/41
F 11 060-02/42

d
mm
19,4
19,9
20,4
20,9
21,4
21,9
22,4
22,9
23,4
23,9
24,4
24,9
25,4
25,9
26,4
26,9
27,4
27,9
28,4
28,9
29,4

Mass/ pcs
kg
0,037
0,039
0,042
0,045
0,045
0,048
0,053
0,056
0,060
0,062
0,065
0,068
0,056

Material:
Filler bolt: Aluminium alloy
Application:
Insert filler bolt in the second groove of the fixing clamp for optical fibre aerial cables when only one cable is guided down the tower.
Remarks:
Fixing clamps: see data-sheet B841/1, B841/2, B841/3 and B841/8
For other executions please inquire.

Stand: 10. August 2006


Pfad: Optofit/ Fixing clamps for tower attachment/ Filler bolts for fixing clamps/
Gedruckt am: 08. Januar 2010

99 / 117

ONLINE-CATALOGUE
B850/0 Introducing to vibration dampers

Aeolian vibrations:
Under certain conditions phase conductors, ground wires and optical fibre aerial cables in transmission lines are excited to mechanical
vibrations by wind. These are causing alternating bending stresses which superpose to the static tensile bending stress.
Suspension- and tension points are especially endangered. As shown in practice for an undamped aerial cable these stresses cause fatigue
breakages of single strands with the possible result of a complete breakage of the optical fibre aerial cable and subsequent breakdown.
Efficient protection against aeolian vibration is given by the installation of suitable vibrations dampers.
Purpose of vibration damper:
Vibration dampers are combined frictional resonance dampers. Purpose of vibration dampers is to dissipate partly the wind power input on
the conductor or optical fibre aerial cable to prevent critical cable stresses.
Function of vibration damper:
The vibration damper consists of a messenger wire with specially formed weights fixed on both ends. The clamp, to mount the damper on the
conductor is fixed between the weights on the messenger wire and transfers the vibrations from the conductor or aerial cable to the
messenger wire. The mechanical vibration energy is transformed within the messenger wire to heat caused by friction. High power
dissipation within the small range of natural frequencies is a characteristic feature of most vibration dampers. Under field conditions,
however, a wide band of natural conductor frequencies has to be expected. Therefore, the dampers must be effective within a wide
frequency band and allow only small residual conductor/ aerial cable amplitudes.
Selection of vibration damper:
The vibration damper, i.e. its mechanical properties (impedance), must fit for the conductor or optical fibre aerial cable. If not, either the
damper can cause damages at its clamp on the conductor or aerial cable, or the damper itself can be destroyed.
Location of vibration damper:
To ensure the optimum efficiency of the vibration dampers, it is necessary to adapt the optimum damper design to the given conditions. This
adaptation requires the determination of the exact damper placement and the number of dampers required.
The most suitable vibration damper is ineffective if it is located in the vibration node, because the conductor or aerial cable is nearly not
moving at this point and thus no vibration energy is transformed into heat. This case must be avoided by determination of a suitable location.
If tension points are concernd this is often only possible with big efforts. In this case two dampers must be located on the conductor or optical
fibre aerial cable nearby the tension point. Thus, it is for sure, that at least on damper is working.
Damping concept:
Every damper is capable to transform a certain amount of vibration energy into heat, without being overloaded. As the vibration energy is
increasing with the length of the span, for longer spans several vibration dampers have to be installed. In special cases, as for example river
crossings, additional damping has to be provided inside the span.
The damping concept gives information about the damper location, the necessary quantity of dampers considering the length of the span and
the type of damper (for example messenger wire made of stainless steel, clamping range etc.)
The damping concept is developed with a computer vibration study. Given the conductor and damper properties, for every installationarrangement and span-length it is proven that the strain of conductors or optical fibre aerial cable (admissible bending strain = 150 m/m)
and vibration dampers remains uncritical and will not cause fatique breakages.
Selection of vibration damper clamp:
The selection of a suitable vibration damper clamp occurs after selection of the vibration damper type. The suitable clamp prevents
excessive strain of optical fibres in a cable. For aerial cables additional protection rods are necessary. When determining the vibration

Stand: 22. Mai 2006


Pfad: Optofit/ Vibration dampers/ Introducing to vibration dampers/
Gedruckt am: 08. Januar 2010

100 / 117

ONLINE-CATALOGUE
damper clamp the total diameter resulting out of the aerial cable diameter plus two times the rod diameter of the protection rods has to be
considered. By means of clamping tests the optimal clamp size and recommended tightening torque of the bolt are determined.

Remarks:
In the following catalog sheets vibration dampers of different sizes with different diameter ranges are shown. It must be underlined that this is
only a rough classification. The exact determination and adjustment of the damper location is made by a calculation of the damper location or
by a vibration study.

Stand: 22. Mai 2006


Pfad: Optofit/ Vibration dampers/ Introducing to vibration dampers/
Gedruckt am: 08. Januar 2010

101 / 117

ONLINE-CATALOGUE
B851/1 Vibration dampers with clamp attachment

Fig. 1

Fig. 2

Fig. 3

Stand: 08. Mai 2007


Pfad: Optofit/ Vibration dampers/ Vibration dampers with clamp attachment/
Gedruckt am: 08. Januar 2010

102 / 117

ONLINE-CATALOGUE
RIBE-Order-No.
Fig.

With messenger cable steel, h.d.g.


and stainless steel bolt

With messenger cable and


stainless steel bolt

1
F 14 856/ X Kb
2
F 14 854/ X Kb
2
F 14 848/ X Kb
3
F 14 841/ X Kb
3
F 14 842/ X Kb
.../X .. - Determination of damper clamp is made by RIBE

F 14 856/ X A2 Kb
F 14 854/ X A2 Kb
F 14 848/ X A2 Kb
F 14 841/ X A2 Kb
F 14 842/ X A2 Kb

Suitable for optical fibre aerial cable


with diameter
mm
14,0 - 19,0
18,0 - 21,0
21,0 - 26,0
25,0 - 29,0
> 28

Type

4 Resonances
2 Resonances
2 Resonances
2 Resonances
2 Resonances

Mass/
pcs
kg
2,1 - 2,5
2,6 - 3,3
3,2 - 4,2
5,9 - 6,3
8,0 - 8,3

Material:
Weights figure no. 1 and 2: Forged steel, h.d.g.
Weights figure no. 3: Steel, casting h.d.g.
Clamp: Forgeds Aluminium alloy
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 08. Mai 2007


Pfad: Optofit/ Vibration dampers/ Vibration dampers with clamp attachment/
Gedruckt am: 08. Januar 2010

103 / 117

ONLINE-CATALOGUE
B851/2 Vibration dampers with clamp attachment (with 3 resonances)

RIBE-Order-No.
With messenger cable steel, h.d.g. and
stainless steel bolt

F 14 872/ X Kb

With messenger cable and stainless Suitable for optical fibre aerial cable with
steel bolt
diameter
mm
F 14 872/ X A2 Kb

9,0 - 16,0

Type

Mass/
pcs
kg

3 Resonances

1,7 - 2,1

.../X .. - Determination of damper clamp is made by RIBE

Material:
Weights: Forgeds steel, h.d.g.
Clamp: Forged aluminium alloy
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 18. August 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with clamp attachment (with 3 resonances)/
Gedruckt am: 08. Januar 2010

104 / 117

ONLINE-CATALOGUE
B853/1 Vibration dampers with helical fixing

RIBE-Order-No.
With messenger wire
With messenger wire
steel, h.d.g.
stainless steel
F 14 873/8
F 14 873/6
F 14 873/1
F 14 873/2
F 14 873/3
F 14 873/4
F 14 873/5
F 14 873/7

F 14 873/8 A2
F 14 873/6 A2
F 14 873/1 A2
F 14 873/2 A2
F 14 873/3 A2
F 14 873/4 A2
F 14 873/5 A2
F 14 873/7 A2

Clamping range

Helical rods
Length Dia. No. of
rods
mm
mm
TW 100 040
400
TW 114 040
400
TW 131 040
400
TW 148 040
400 3,25
3
TW 166 040
400
TW 185 043
430
TW 205 048
480
TW 225 052
520

Type

Mass/
pcs

RIBE-No.

mm
8,80 - 10,09
10,10 - 11,49
11,50 - 13,10
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,55

mm mm
35,5
36,5
38,0
39,5 405
41,0
43,0
45,0
46,5

kg

3 Resonances

1,55

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Mai 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

105 / 117

ONLINE-CATALOGUE
B853/2 Vibration dampers with helical fixing

RIBE-Order-No.
With messenger wire
With messenger wire
Steel, h.d.g.
Stainless steel
B 161 001/1
B 161 001/2
B 161 001/3
B 161 001/4
B 161 001/5
B 161 001/6
B 161 001/7

B 161 001/1 A2
B 161 001/2 A2
B 161 001/3 A2
B 161 001/4 A2
B 161 001/5 A2
B 161 001/6 A2
B 161 001/7 A2

Clamping range

Helical rods
H
L
Length Dia. No. of
rods
mm
mm
mm mm
TW 202 062
55,0
TW 226 062
57,0
TW 252 062
59,5
TW 280 062
620 3,25
3
62,0 460
TW 310 062
64,5
TW 340 062
67,5
TW 370 062
70,0

Type

Mass/
pcs

RIBE-No.

mm
18,50 - 20,20
20,21 - 22,60
22,61 - 25,20
25,21 - 28,00
28,01 - 31,00
31,01 - 34,00
34,01 - 37,00

kg

2 Resonances

2,5

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Mai 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

106 / 117

ONLINE-CATALOGUE
B853/3 Vibration dampers with helical fixing

RIBE-Order-No.
With messenger wire
With messenger wire
Steel, h.d.g.
Stainless steel
B 161 003/1
B 161 003/2
B 161 003/3
B 161 003/4
B 161 003/5
B 161 003/6
B 161 003/7
B 161 003/9
B 161 003/10

B 161 001/1 A2
B 161 003/2 A2
B 161 003/3 A2
B 161 003/4 A2
B 161 003/5 A2
B 161 003/6 A2
B 161 003/7 A2
B 161 003/9 A2
B 161 003/10 A2

Clamping range

Helical rods
Length Dia. No. of
rods
mm
mm
TW 202 062
620
TW 226 062
620
TW 252 062
620
TW 280 062
620
TW 310 062
620 3,25
3
TW 340 062
620
TW 370 062
620
TW 160 062
620
TW 179 053
530

Type

Mass/
pcs

RIBE-No.

mm
18,50 - 20,20
20,21 - 22,60
22,61 - 25,20
25,21 - 28,00
28,01 - 31,00
31,01 - 34,00
34,01 - 37,00
14,00 - 16,00
16,01 - 17,99

mm mm
55,0
57,0
59,5
62,0
64,5 480
67,5
70,0
52,5
53,5

kg

4 Resonances

2,1

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Februar 2009


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

107 / 117

ONLINE-CATALOGUE
B853/4 Vibration dampers with helical fixing

RIBE-Order-No.
With messenger wire
With messenger wire
Steel, h.d.g.
Stainless steel
B 161 002/1
B 161 002/2
B 161 002/3
B 161 002/4
B 161 002/5
B 161 002/6
B 161 002/7

B 161 002/1 A2
B 161 002/2 A2
B 161 002/3 A2
B 161 002/4 A2
B 161 002/5 A2
B 161 002/6 A2
B 161 002/7 A2

Clamping range

Helical rods
H
L
Length Dia. No. of
rods
mm
mm
mm mm
TW 202 062
55,0
TW 226 062
57,0
TW 252 062
59,5
TW 280 062
620 3,25
3
62,0 465
TW 310 062
64,5
TW 340 062
67,5
TW 370 062
70,0

Type

Mass/
pcs

RIBE-No.

mm
18,50 - 20,20
20,21 - 22,60
22,61 - 25,20
25,21 - 28,00
28,01 - 31,00
31,01 - 34,00
34,01 - 37,00

kg

2 Resonances

3,3

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Mai 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

108 / 117

ONLINE-CATALOGUE
B853/5 Vibration dampers with helical fixing

RIBE-Order-No.
With messenger wire
With messenger wire
Steel, h.d.g.
Stainless steel
B 853 002/1
B 853 002/2
B 853 002/3
B 853 002/4
B 853 002/5
B 853 002/6

B 853 002/1 A2
B 853 002/2 A2
B 853 002/3 A2
B 853 002/4 A2
B 853 002/5 A2
B 853 002/6 A2

Clamping range

Helical rods
H
L
Length Dia. No. of
rods
mm
mm
mm mm
TW 148 040
400
42
TW 166 040
400
44
TW 185 043
430
3,25
3
46 470
TW 205 048
480
48
TW 225 052
520
50
TW 252 062
620
52

Type

Mass/
pcs

RIBE-No.

mm
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,60
22,61 - 25,20

kg

4 Resonances

2,1

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Mai 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

109 / 117

ONLINE-CATALOGUE
B853/6 Vibration dampers with helical fixing

RIBE-Orderlno.
With messenger cable
With messenger wire
Steel, h.d.g.
Stainless steel
B 853 004/1
B 853 004/2
B 853 004/3
B 853 004/4
B 853 004/5
B 853 004/6

B 853 004/1 A2
B 853 004/2 A2
B 853 004/3 A2
B 853 004/4 A2
B 853 004/5 A2
B 853 004/6 A2

Clamping range

Helical rods
H L
Length Dia. No. of
rods
mm
mm
mm mm
TW 148 040
400
42
TW 166 040
400
44
TW 185 043
430 3,25
3
46 455
TW 205 048
480
48
TW 225 052
520
50
TW 252 062
620
52

Type

Mass/
pcs

RIBE-No.

mm
13,11 - 14,81
14,82 - 16,62
16,63 - 18,53
18,54 - 20,54
20,55 - 22,60
22,61 - 25,20

kg

2 Resonances

2,5

Material:
Weights: Forged steel, h.d.g.
Clamp: Extruded profile
Armor rods: Aluminium-clad steel
Remark:
The determination of damper type, clamp and number of vibration dampers to be installed will be done by RIBE.

Stand: 09. Mai 2006


Pfad: Optofit/ Vibration dampers/ Vibration dampers with helical fixing/
Gedruckt am: 08. Januar 2010

110 / 117

ONLINE-CATALOGUE
B855/2 Avibra-Vibration dampers for ADSS cables

1 ..... Gripping section


2 ..... Damping section
RIBE-Order-No.

DB 098 081
DB 110 093
DB 122 094
DB 137 112
DB 152 119
DB 169 126
DB 189 135
DB 211 138
DB 235 149
DB 262 155

Clamping range

Mass/ pcs

mm
-

mm
12,5
12,5
12,5
12,5
12,5
12,5
16,0
16,0
16,0
16,0

mm
810
930
1040
1125
1190
1265
1350
1380
1490
1550

kg
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,3
0,3
0,3

8,87
9,89
11,03
12,30
13,71
15,25
17,00
18,95
21,12
23,54

9,88
11,02
12,29
13,70
15,24
16,99
18,94
21,1
23,53
26,22

Material:
Helical rod: Weather-proof wear-resistant plastic
Application:
Purpose of Avibra vibration dampers is to dissipate the wind power input on the ADSS cable to prevent critical conductor stresses.
The Avibra vibration damper is composed of a helically formed plastic rod. About one fifth of the overall length of the helix is of smaller
diameter. This section is used to attach the damper and provides a completely reliable grip on the ADSS cable so that the damper will
not slip even on slopes. The remaining length of the helix has no close contact to the cable. Due to differential motions between ADSS
cable and Avibra damper, the ADSS cable vibrations are eliminated.
Installation:
Avibra vibration dampers are installed by first wrapping the gripping section (smaller helix) and afterwards the damping section on the
optical fibre aerial cable.
The damper must be installed in such a way that the gripping section is placed towards the tower and the damping section towards the
free span. No special tools are required for installation.
Avibra vibration dampers can be installed without problems on any existing cable - even subsequently.
For installtion follow RIBE-Mounting Instruction No. 17.

Stand: 18. Dezember 2009


Pfad: Optofit/ Vibration dampers/ Avibra-Vibration dampers for ADSS cables/
Gedruckt am: 08. Januar 2010

111 / 117

ONLINE-CATALOGUE
B860 Helically formed accessories for antenneas

Protection rods and line splices from steel for glass fibre rods in antennae constructions

Application:
Protection rods for glass fibre rods are mainly required for antennae constructions, protecting the glass fibre rods from mechanical
influences like abrasion and compressive strains at the highly stressed points.
Line splices are suitable for the full-tension connection of glass fibre rods.
Cross-tie connectors from steel for glass fibre rods in antennae constructions

Application:
Cross-tie rods are applied in antennae constructions connecting two crossing glass fibre rods mechanically.
Dead ends from steel for glass fibre rods in antennae constructions

Stand: 25. April 2006


Pfad: Optofit/ Fittings for antennae/ Helically formed accessories for antenneas/
Gedruckt am: 08. Januar 2010

112 / 117

ONLINE-CATALOGUE

Application:
Helical dead ends are particular for tensioning of glass fibre rods in antennae construction.
Remark:
Additional preformed accessories for glass fiber rods in antennae constructions are available on request.

Stand: 25. April 2006


Pfad: Optofit/ Fittings for antennae/ Helically formed accessories for antenneas/
Gedruckt am: 08. Januar 2010

113 / 117

ONLINE-CATALOGUE
B891/1 Fittings for fastening of attached optical cables to supporting conductors

1 ..... Fixing rod


2 ..... Fixing clamp
3 ..... Binder
4 ..... Supporting conductor
5 ..... Attached optical cable
6 ..... Attachment for binder
Fixing rods
RIBE-Order-No.

Diameter of supporting conductor

L1

L2

B 891 002/1
B 891 002/2
B 891 002/3
B 891 002/4

mm
6,34 - 8,28
8,29 - 11,70
11,71 15,00
15,01 18,99

mm
1000
1000
1000
1000

mm
260
290
371
404

Material:
Helical rod: PVC
Fixing clamps for one attached optical cable on one supporting conductor
RIBE-Order-No.

B 891 004/45
B 891 004/46
B 891 004/47
B 891 004/48
B 891 004/1
B 891 004/2
B 891 004/3
B 891 004/4
B 891 004/5
B 891 004/6
B 891 004/7
B 891 004/8

Clamping range
Supporting conductor
Attached optical cable
mm
mm
6,00 - 6,50
6,5 7,5
6,51 - 7,00
6,5 7,5
7,01 - 7,50
6,5 7,5
7,51 - 7,99
6,5 7,5
8,00 - 8,50
6,5 7,5
8,51 - 9,00
6,5 7,5
9,01 - 9,50
6,5 7,5
9,51 - 10,00
6,5 7,5
10,01 - 10,50
6,5 7,5
10,51 - 11,00
6,5 7,5
11,01 - 11,50
6,5 7,5
11,51 - 12,00
6,5 7,5

RIBE-Order-No.

B 891 004-10/45
B 891 004-10/46
B 891 004-10/47
B 891 004-10/48
B 891 004-10/1
B 891 004-10/2
B 891 004-10/3
B 891 004-10/4
B 891 004-10/5
B 891 004-10/6
B 891 004-10/7
B 891 004-10/8

Stand: 20. Mrz 2007


Pfad: Optofit/Special Accessories/ Fittings for fastening of attached optical cables to supporting conductors/
Gedruckt am: 08. Januar 2010

Clamping range
Supporting conductor
Attached optical cable
mm
mm
6,00 - 6,50
11,5 12,5
6,51 - 7,00
11,5 12,5
7,01 - 7,50
11,5 12,5
7,51 - 7,99
11,5 12,5
8,00 - 8,50
11,5 12,5
8,51 - 9,00
11,5 12,5
9,01 - 9,50
11,5 12,5
9,51 - 10,00
11,5 12,5
10,01 - 10,50
11,5 12,5
10,51 - 11,00
11,5 12,5
11,01 - 11,50
11,5 12,5
11,51 - 12,00
11,5 12,5

114 / 117

ONLINE-CATALOGUE
RIBE-Order-No.

B 891 004/9
B 891 004/10
B 891 004/11
B 891 004/12
B 891 004/13
B 891 004/14
B 891 004/15
B 891 004/16
B 891 004/17
B 891 004/18
B 891 004/19
B 891 004/20
B 891 004/21
B 891 004/22
B 891 004/23
B 891 004/24
B 891 004/25
B 891 004/26
B 891 004/27
B 891 004/28
B 891 004/29
B 891 004/30
B 891 004/31
B 891 004/32
B 891 004/33
B 891 004/34
B 891 004/35
B 891 004/36
B 891 004/37
B 891 004/38
B 891 004/39
B 891 004/40
B 891 004/41
B 891 004/42
B 891 004/43
B 891 004/44

Clamping range
Supporting conductor
Attached optical cable
mm
mm
12,01 - 12,51
6,5 7,5
12,51 - 13,00
6,5 7,5
13,01 - 13,50
6,5 7,5
13,51 - 14,00
6,5 7,5
14,01 - 14,50
6,5 7,5
14,51 - 15,00
6,5 7,5
15,01 - 15,50
6,5 7,5
15,51 - 16,00
6,5 7,5
16,01 - 16,50
6,5 7,5
16,51 - 17,00
6,5 7,5
17,01 - 17,50
6,5 7,5
17,51 - 18,00
6,5 7,5
18,01 - 18,50
6,5 7,5
18,51 - 19,00
6,5 7,5
19,01 - 19,50
6,5 7,5
19,51 - 20,00
6,5 7,5
20,01 - 20,50
6,5 7,5
20,51 - 21,00
6,5 7,5
21,01 - 21,50
6,5 7,5
21,51 - 22,00
6,5 7,5
22,01 - 22,50
6,5 7,5
22,51 - 23,00
6,5 7,5
23,01 - 23,50
6,5 7,5
23,51 - 24,00
6,5 7,5
24,01 - 24,50
6,5 7,5
24,51 - 25,00
6,5 7,5
25,01 - 25,50
6,5 7,5
25,51 - 26,00
6,5 7,5
26,01 - 26,50
6,5 7,5
26,51 - 27,00
6,5 7,5
27,01 - 27,50
6,5 7,5
27,51 - 28,00
6,5 7,5
28,01 - 28,50
6,5 7,5
28,51 - 29,00
6,5 7,5
29,01 - 29,50
6,5 7,5
29,51 - 30,00
6,5 7,5

RIBE-Order-No.

B 891 004-10/9
B 891 004-10/10
B 891 004-10/11
B 891 004-10/12
B 891 004-10/13
B 891 004-10/14
B 891 004-10/15
B 891 004-10/16
B 891 004-10/17
B 891 004-10/18
B 891 004-10/19
B 891 004-10/20
B 891 004-10/21
B 891 004-10/22
B 891 004-10/23
B 891 004-10/24
B 891 004-10/25
B 891 004-10/26
B 891 004-10/27
B 891 004-10/28
B 891 004-10/29
B 891 004-10/30
B 891 004-10/31
B 891 004-10/32
B 891 004-10/33
B 891 004-10/34
B 891 004-10/35
B 891 004-10/36
B 891 004-10/37
B 891 004-10/38
B 891 004-10/39
B 891 004-10/40
B 891 004-10/41
B 891 004-10/42
B 891 004-10/43
B 891 004-10/44
B 891 004-10/49
B 891 004-10/50
B 891 004-10/51
B 891 004-10/52

Clamping range
Supporting conductor
Attached optical cable
mm
mm
12,01 - 12,51
11,5 12,5
12,51 - 13,00
11,5 12,5
13,01 - 13,50
11,5 12,5
13,51 - 14,00
11,5 12,5
14,01 - 14,50
11,5 12,5
14,51 - 15,00
11,5 12,5
15,01 - 15,50
11,5 12,5
15,51 - 16,00
11,5 12,5
16,01 - 16,50
11,5 12,5
16,51 - 17,00
11,5 12,5
17,01 - 17,50
11,5 12,5
17,51 - 18,00
11,5 12,5
18,01 - 18,50
11,5 12,5
18,51 - 19,00
11,5 12,5
19,01 - 19,50
11,5 12,5
19,51 - 20,00
11,5 12,5
20,01 - 20,50
11,5 12,5
20,51 - 21,00
11,5 12,5
21,01 - 21,50
11,5 12,5
21,51 - 22,00
11,5 12,5
22,01 - 22,50
11,5 12,5
22,51 - 23,00
11,5 12,5
23,01 - 23,50
11,5 12,5
23,51 - 24,00
11,5 12,5
24,01 - 24,50
11,5 12,5
24,51 - 25,00
11,5 12,5
25,01 - 25,50
11,5 12,5
25,51 - 26,00
11,5 12,5
26,01 - 26,50
11,5 12,5
26,51 - 27,00
11,5 12,5
27,01 - 27,50
11,5 12,5
27,51 - 28,00
11,5 12,5
28,01 - 28,50
11,5 12,5
28,51 - 29,00
11,5 12,5
29,01 - 29,50
11,5 12,5
29,51 - 30,00
11,5 12,5
30,01 - 30,50
11,5 12,5
30,51 - 31,00
11,5 12,5
31,01 - 31,50
11,5 12,5
31,51 - 32,00
11,5 12,5

Material:
Clamp: Aluminium, forged
Bolt, nuts, washers:Stainless steel
Insert: EPDM

Stand: 20. Mrz 2007


Pfad: Optofit/Special Accessories/ Fittings for fastening of attached optical cables to supporting conductors/
Gedruckt am: 08. Januar 2010

115 / 117

ONLINE-CATALOGUE
Installation:
Recommended tightening torque for bolt: 46 Nm
Fixing clamps with two different grooves for two attached optical cables
Clamping range

RIBE-Order-No.

B 891 001-10/1

Attached optical cable 1


mm
6,5

Attached optical cable 2


mm
6,5

Material:
Clamp: Aluminium, forged
Bolt, nuts, washers: Stainless steel
Protection tube: Plastic material
Installation:
Recommended tightening torque for bolt: 46 Nm

Stand: 20. Mrz 2007


Pfad: Optofit/Special Accessories/ Fittings for fastening of attached optical cables to supporting conductors/
Gedruckt am: 08. Januar 2010

116 / 117

ONLINE-CATALOGUE
B891/2 Routing rods (fittings for attached optical cables)

1 ..... Supporting conductor


2 ..... Attached optical cable
3 ..... Vibration damper
4 ..... UFA-routing rod
RIBE-Order-No.
UFA 125 250
UFA 161 250
UFA 197 250
UFA 233 250
UFA 269 250
UFA 305 250

Clamping range
mm
9,0 - 12,5
12,6 - 16,1
16,2 - 19,7
19,8 - 23,3
23,4 - 26,9
27,0 - 30,5

L
mm
2500
2500
2500
2500
2500
2500

Dia. of rods
mm
3,45
3,45
3,45
3,70
3,70
4,24

No. of rods
1
1
1
1
1
1

Mass/ pcs
kg
0,068
0,068
0,068
0,077
0,077
0,101

Material:
Rod: Aluminium alloy
Application:
This system of fittings serves to fasten attached optical cables to supporting conductors and to guide them in routing and down lead
arrangements.

Stand: 11. Mai 2006


Pfad: Optofit/Special Accessories/ Routing rods (fittings for attached optical cables)/
Gedruckt am: 08. Januar 2010

117 / 117

Vous aimerez peut-être aussi