Vous êtes sur la page 1sur 16

----------------------- Page 1-----------------------

INSTRUCTION
1 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved

Checked
Date

Rev

2014-07-25

Reference

MOP SIU REPLACEMENT FOR VNP2


Section
Page
1
LAPTOP SETUP: ...........................
........................................................ 2
2
BACKUP SIU CONFIGURATION FILE (XML) TO LA
PTOP. .................. 3
3
SITE SPECIFIC STEP-BY-STEP ..............
............................................. 4
4
SWAP SIU HARDWARE .......................
............................................... 10

This MOP describes the procedure to replace all SIUs with productRevision
=R1G on live network VNP2.
The procedure is used the step by step for backup a configuration on one S
IU and then restore this
configuration on another SIU which will replace in. For here, ASP/SUB wil
l be easy implement SIU replacement,
and also less impact to customer services.

Important notes for ASP/SUB :


Be sure to have the correct SIU Software (T12B_ CXP 102 138/1 R2AB).

This software will be getting from


E///.
Laptop must be working well.
Ethernet cable.
Software supports SSH/Telnet (Puty or Secure CRT).
Software supports SFTP server (should be used Core FTP mini).
Site specific configuration (xml file) backup file included in this p
rocedure.
Make sure replaced new SIU is different version R1G.
Once you have had the correct SIU software and backup file, extract those t
o a folder off your PC in C:\ SIU. If
you havent already created a SIU folder off your C:\ drive.

----------------------- Page 2-----------------------

INSTRUCTION
2 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved

Checked
Rev

2014-07-25

Date

Reference

LAPTOP SETUP:
SETUP Description

NOTE: If you have any problems with any steps of this MOP, DO NOT PROCEED
, Contact your PM immediately.
The Steps below need to be executed in the specified sequence on all impa
cted nodes.
SET COMPUTER IP TO:
192.168.1.2
255.255.255.0
192.168.1.1
Setup a telnet session for connecting to SIU local console port:

SIU IP address: 192.168.1.1


login: admin
password: hidden
LAUNCH FTP PROGRAM (User: siu ; Pass: siu) & Port: 22
1.
Double click on the file msftpsrvr.e
xe to start the mini-sftp server program on your PC.
2.
Change these values on the mini-sftp
-server as below
3.
The password is <siu>
4.
Then click on start button to start
the SFTP server

----------------------- Page 3-----------------------

INSTR
UCTION

3 (11)

Prepared (also subject responsible if other)

No.

Lai Le
Approved

Checked
Rev

Date

Reference
2014-

07-25

A
2

BACKUP SIU CONFIGURATION FILE (XML) TO LAPTOP.


(Activities on existing SIU)
Step

Description

Backup SIU xml file to Laptop


1

Login to SIU will be replaced:


ssh admin@192.168.1.1
Pass: hidden
Setting ly logfile th 1, file lu theo quy

tc SIU_HCxxxx_old.log

xxxx: l s c th ca trm .
2

Check Product Revision and Serial code


OSmon> getmoattribute STN=0,Equipment=0
STN=0,Equipment=0; instanceId= 0;
STN=0,Equipment=0; serialNumber= CB4H230708;
STN=0,Equipment=0; productRevision= R1G; (or: R1G/A; R1E

/C)
STN=0,Equipment=0; productNumber= KDU 137 596/2;
STN=0,Equipment=0; manufacturingDate= 20110404;
OperationSucceeded
Note: Product Revisions are R1G; R1G/A; R1E/C must be rep
laced by another one.
Check alarm SIU
3
OSmon> getalarmlist
OperationSucceeded
Note: Please capture/get alarm screen on existing SIU.
OSmon> getmoattribute stn=0
4
OSmon> getmoattribute

----------------------- Page 4-----------------------

INSTRUCTION

4 (11)

Prepared (also subject responsible if other)


No.
Lai Le
Approved
Date

Rev

Checked

2014-07-25

Reference

OSmon> getmoattribute STN=0,TGTransport=all


5
Heres 2G ID.
STN=0,TGTransport=HC1047_TG900; instanceId= HC1047_TG90

0;
STN=0,TGTransport=HC1047_TG900; operationalState= enabl
ed;
STN=0,TGTransport=HC1047_TG900; PGW_IP_Address= 10.213.
240.195;
STN=0,TGTransport=HC1047_TG900; depIP_Interface= STN=0,
IPInterface=2G;
STN=0,TGTransport=HC1047_TG900; STN_PGW_LinkStatus= up;
STN=0,TGTransport=HC1047_TG900; overloadThreshold= 1000
;
STN=0,TGTransport=HC1047_TG900; overloadReportInterval=
1;
STN=0,TGTransport=HC1047_TG900; DSCP_L2TP_CP= 40;
OperationSucceeded
====> From here, we can know this SIU has used for 2G o
r not, and know whats
2G ID.
Backup the SIU xml configuration to Laptop
4
OSmon> uselocalsftp on
OperationSucceeded
OSmon> startSession bcm1
OperationSucceeded
OSmon> backup bcm1 sftp://siu:siu@192.168.1.2/SIU/SIU_H
Cxxx.xml admin
OperationSucceeded
OSmon> getsessionstatus bcm1
UploadCompleted
OperationSucceeded
OSmon> endSession bcm1
A backup xml file will appear at path on laptop: C/SIU/
This backup xml file will used to restore for replaced
new SIU.
3

SITE SPECIFIC STEP-BY-STEP


(Activities on new SIU)

Power cables are connected temporary to new


SIU from PWR out 2 port of RBS 6601.
-

Check the power LED indicator is lit.

Connect an Ethernet cable from the laptop p


ort to the Console port on the SIU.
1.

----------------------- Page 5-----------------------

INSTRUCTION
5 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved

Checked
Date

Rev

2014-07-25

Reference

A
The SIU local maintenance IP address is 192.168.1.1

(Sub netmask 255.255.255.0).


login: admin
2.
Password: hidden
Reset SIU to factory setting. (Ch thc hin trn con SIU
mi)
OSmon> resetToFactorySetting
3.
Warning: All user settings will be removed, continu
e (ok/cancel)? OK.
OperationSucceeded
Re-Login SIU:
4.
Setting ly logfile th 2, file lu theo
quy tc SIU_HCxxxx_before_upgrade.log
Check current HW revision
OSmon> getmoattribute STN=0,Equipment=0
STN=0,Equipment=0; instanceId= 0;
STN=0,Equipment=0; serialNumber= CB4B682659;
STN=0,Equipment=0; productRevision= R1E/ D; ======
=========> Revision OK.
STN=0,Equipment=0; productNumber= KDU 137 596/2;
5.
STN=0,Equipment=0; manufacturingDate= 20100111;

OperationSucceeded
The new SIU has productRevision must be different
with R1G; R1G/A; R1E/C.

----------------------- Page 6-----------------------

INSTRUCTION
6 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved
Checked
Reference

Date

Rev

2014-07-25

Check current SIU Software

(Check the curren

t SIU software level as follows)


OSmon> rev
------------------- OSE modules ----------------------------------------oam.chk

Operation & Main


R2J01
Security Manager
R2G02
MLPPP Daemon
R2D03
Local Terminal
R2D03
Synchronization
R2H02
Packet Distribut
R1L_1
C

tenance
secmgrr.chk
inetr.chk
ltp.chk
Port
snc.chk
pd.chk
or
cesopsn_pwr.chk
ircuit Emulation Service

R1F03
hdlc_pwr.chk

Emulation
p_relayr.chk
profiler.chk

HDLC Pseudo-Wire
R1H07
Packet Relay
R2H01
System Profiler

R1L_1
Hardware Tester
P2A01
Local Connectivi
R1C01
Board Support Pa
R2H02
Bootstrap
R2G02
Software Loader
R1L_1

hwtest.chk
lcf_cp.chk
ty Function
bsp.drv
ckage
bootstrap.chk
loader.drv
6.
linuxload.drv

Linux Loader
R2H02

------------------- Firmware modules -----------------------------------PBOOT

CXC 112 3777/1


R1G02
------------------- Software archives ----------------------------------Primary:
OSE
Linux

CXP102128_1
R2J01
R2J01

Backup:
OSE

CXP102084_1
R3F01
------------------- Active software ------------------------------------OSE
Primary
Linux
Primary
In this case: CXP102128_1 (R2J01) is version T
11B, old version. So, We must be upgraded to
correct SW T12B: CXP 102 138/1 R2AB as step 7.

----------------------- Page 7-----------------------

INSTRUCTION
7 (11)

Prepared (also subject responsible if other)


No.
Lai Le
Approved
d

Date

Rev

2014-07-25

Checke
Reference

Upgrade SIU Software step by step:


The software upgrade requires a SFTP server runni
ng on your PC. The software and configuration files will
be downloaded from your PC to the SIU.
Start the SFTP server on your PC and configure it
with the username and password siu and set Root path to
c:
Enter the following commands:
OSmon> uselocalsftp on
OSmon> startswsession 1
OperationSucceeded
OSmon> downloadsw 1 sftp://siu:siu@192.168.1.2/SI
U/T12B_siu02_sw.tar
OperationSucceeded
7.
OSmon> getswsessionstatus 1
DownloadInProgress
OperationSucceeded
Wait up to 5 minutes for the software download to
complete.
OSmon> getswsessionstatus 1
DownloadCompleted
OperationSucceeded
When the software download is completed, activate
the software using the following command:
OSmon> activatesw 1
OperationSucceeded
The SIU will restart and connectivity will be lost
.

----------------------- Page 8-----------------------

INSTRUCTION
8 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved
Checked
Reference

Date

Rev

2014-07-25

Re-Login to the SIU:


Setting ly logfile th 3, file lu theo q
uy tc SIU_HCxxxx_after_upgrade.log
OSmon> getswsessionstatus 1
ActivationCompleted
SIU Software upgrade was successful

====>

OperationSucceeded
OSmon> endswsession 1
OperationSucceeded
Check the software revision and verify that the
primary software is the latest version and the SIU is running on
the primary application as follows:
OSmon> rev
------------------- OSE modules ----------------------------------------oam.chk
tenance
secmgrr.chk
inetr.chk
ltp.chk
Port
snc.chk
pd.chk
or

Operation & Main


R2J01
Security Manager
R2G02
MLPPP Daemon
R2D03
Local Terminal
R2D03
Synchronization
R2H02
Packet Distribut
R1L_1

8.
cesopsn_pwr.chk
hdlc_pwr.chk

Circuit Emulation Service


R1F03
HDLC Pseudo-Wire
R1H07
Packet Relay
R2H01
System Profiler
R1L_1
Hardware Tester
P2A01
Local Connectivi
R1C01
Board Support Pa
R2H02
Bootstrap
R2G02
Software Loader
R1L_1
Linux Loader
R2H02

Emulation
p_relayr.chk
profiler.chk
hwtest.chk
lcf_cp.chk
ty Function
bsp.drv
ckage
bootstrap.chk
loader.drv
linuxload.drv

------------------- Firmware modules -----------------------------------PBOOT

CXC 112 3777/1


R1G02
------------------- Software archives ----------------------------------Primary:
OSE
Linux

CXP102138_1
R2AB05
R2AB05

Backup:
OSE

CXP102084_1
R3F01
------------------- Active software ------------------------------------OSE
Primary
Linux
Primary
Make sure the primary is activated software T1
2B.

----------------------- Page 9-----------------------

INSTRUCTION
9 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved
ecked
rence

Date

Rev

2014-07-25

Ch
Refe

Restore SIU configuration xml file.


(Configuration xml file has just gotten from ste
p of item 2 above)
Make sure your SFTP server is running. The SIU c
onfiguration file must be in XML format.
OSmon> uselocalsftp on
OSmon> startsession bcm1
OperationSucceeded
OSmon> download bcm1 sftp://siu:siu@192.168.1.2/
SIU/SIU_HCxxx.xml
OperationSucceeded
9.
OSmon> getsessionstatus bcm1
DownloadCompleted
OperationSucceeded
When the file download is complete, activate the
configuration using the following command:
Osmon> restore bcm1 admin
OperationSucceeded
The SIU will restart and connectivity will be lo
st
Re-Login to the SIU and enter the following comm
ands:
Setting ly logfile th 4, file lu theo q
uy tc SIU_HCxxxx_ready.log
OSmon> getsessionstatus bcm1
ActivationCompleted
10.
OperationSucceeded
OSmon> endsession bcm1

OperationSucceeded
Note: If any errors are encountered while loadin
g the script, contact Ericsson support.
OSmon> getalarmlist
OSmon> getmoattribute stn=0
OSmon> getmoattribute stn=0,equipment=0
11.
OSmon> getmoattribute

----------------------- Page 10-----------------------

INSTRUCTION
10 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved
Date

Rev

2014-07-25

Checked
Reference

Check SIU LED indicators are normal


Refer to figure in step 1 to locate the LED indica
tors in the SIU.
Indicator Status
Fault
Power

Off
On

12.
Opera.

On

Sync

On

Info.

Off

If the Fault or Info. LED is lit, troubleshoot and


clear the fault.
Make sure, all ports and parameters on new SIU are
defined correct as existing SIU.
4

SWAP SIU HARDWARE

- Make sure, new SIU finished restoration configu


ration & working status is ready.
1.
- Must be making labels on all cables connected to
ports of existing SIU. ===> very very important.

- After, anything is ready. ASP will call for E///


guys confirm starting time swap SIU. When accepted by E///.
ASP will turn off power existing SIU & replace ne
w SIU.
- Make sure, all cable are reconnected correction
as before swap.
2.
- Check physical links are up.
- And then, ASP need contact with E/// guys as soo
n as possible.

----------------------- Page 11-----------------------

INSTRUCTION
11 (11)
Prepared (also subject responsible if other)
No.
Lai Le
Approved
ked
e

Date

Rev

Chec
Referenc

2014-07-25

Log-in to new SIU after replaced and enter the f


ollowing commands:
Setting ly logfile th 5, file lu theo qu
y tc SIU_HCxxxx_new.log
Check alarms in the SIU
3.

OSmon> getalarmlist
Troubleshoot and clear any alarms.
Note:

- Make sure after swap, all alarms are the same


as before swap on the both SIU/Node B/RBS 2G.
Ping to OSS
OSmon> ping 10.149.27.67
PING (10.26.2.65) 56(84) bytes of data.
64 bytes from 10.26.2.65: icmp_seq=0 ttl=255 time
=1.824 ms
64 bytes from 10.26.2.65: icmp_seq=1 ttl=255 time
=1.702 ms
64 bytes from 10.26.2.65: icmp_seq=2 ttl=255 time
=1.681 ms
4.

64 bytes from 10.26.2.65: icmp_seq=3 ttl=255 time

=1.706 ms
64 bytes from 10.26.2.65: icmp_seq=4 ttl=255 time
=1.715 ms
--- 10.26.2.65 ping statistics --5 packets transmitted, 5 received, 0.0% packet lo
ss
round-trip min/avg/max = 1.000/1.725/1.823 ms
===> To stop ping result, use CRT+C
If the ping is not successful, then troubleshoot
.
Note: Make sure ping to OSS ok.
Enter the following commands to print the SIU co
nfiguration:
OSmon> getmoattribute stn=0
OSmon> getmoattribute stn=0,equipment=0
5.
OSmon> getmoattribute
OSmon> log read

All 5 logfiles will keep on your laptop and send


to Ericsson for audit (or V NP requirement later on).
6
Waiting confirm from OMC/Eric before leave the si
te.

Vous aimerez peut-être aussi