1.0
2.0
3.0
DOC. NO.
REV.
PAGE
DATE
CIT/MS/LRCRT/001
0
2 of 5
19/09/2013
INTRODUCTION
1.1
1.2
1.3
Objective :
i. To achieve safe distance 3 until 5 meters using Lo-Rad equipment during
exposure time.
ii. Minimize waiting time for RT result. May get RT result in few minutes after
scan the exposed imaging plate into CRT software. No chemical processing
will involve as in conventional film processing.
iii.
Minimize time for finalizing and interpreting RT result especially for critical
and urgent RT joint.
iv. No using of conventional RT film. Replaced with CRT imaging plate that can
re-use many time after previous shoot.
SAFETY
2.1
All radiographers shall be registered with AELB and operated within the allowable
permits.
2.2
All radiographers and assistant mandatory to wear film badge or TLD badge
everytime involve with radiography testing work.
2.3
The perimeter of boundary beyond which no radiation level is in excess of 0.75 mR/hr
(7.5 Sv/hr) shall be cordoned off with yellow rope (where practical) and warning
sign boards and flashing lights shall be placed at strategic locations.
2.4
The radiation level shall be monitored by using a calibrated radiation survey meter.
2.5
SURFACE PREPARATION
Weld or surface of object to be inspected shall be as follows:
3.1
3.2
3.3
4.0
CIT/MS/LRCRT/001
0
3 of 5
19/09/2013
3.4
The finish surface may be flushed with the base material or may be have uniform
crown.
3.5
Methods or preparation shall be such that over heating or loss of material integrity
does not occur.
3.6
Surface shall satisfy the requirements of the applicable materials specifications, with
additional conditioning, if necessary, by any suitable process to a degree that surface
irregularities cannot mask or be confused with discontinuities.
RADIOGRAPHIC EQUIPMENT
4.1
Major RT Equipment
i.
ii.
iii.
4.2
4.3
Gamma projector
Windle cable
Guide tube
Lo-Rad Equipment
i.
ii.
iii.
iv.
v.
vi.
5.0
DOC. NO.
REV.
PAGE
DATE
PRIOR TO WORK
5.1
RT equipment setting for RT Lo-Rad combined with CRT is same as preparation for
RT conventional (refer Radiography Testing Procedure).
5.2
For additional, weld or surface to be inspected will wrapped with Lo-Rad Mazel Mats
to achieve the safe distance 3-5 meters. See Figure 1.0.
DOC. NO.
REV.
PAGE
DATE
CIT/MS/LRCRT/001
0
4 of 5
19/09/2013
DURING WORK
6.1
6.2
6.3
6.4
Once the exposure complete, the imaging plate will sliding onto the CRT scanner to
transfer the image into CRT software. May choose the option either to maintain the
image in imaging plate or erase it for re-use.
FIGURE 2.0 : Sliding imaging plate onto CRT scanner for image transfer to CRT software.
7.0
DOC. NO.
REV.
PAGE
DATE
CIT/MS/LRCRT/001
0
AFTER WORK
7.1
5 of 5
19/09/2013