METHOD STATEMENT COMBINATION OF

RADIOGRAPHIC TESTING USING LO-RAD AND


CRT EQUIPMENT

1.0

2.0

3.0

DOC. NO.
REV.
PAGE
DATE

CIT/MS/LRCRT/001
0

2 of 5
19/09/2013

INTRODUCTION
1.1

This method statement is developed to cover the Radiographic Testing combination


of Lo-Rad equipment and Computed Radiography Testing (CRT) equipment.

1.2

This method statement is covered by Radiography Testing procedure and Computed


Radiography Testing procedure.

1.3

Objective :
i. To achieve safe distance 3 until 5 meters using Lo-Rad equipment during
exposure time.
ii. Minimize waiting time for RT result. May get RT result in few minutes after
scan the exposed imaging plate into CRT software. No chemical processing
will involve as in conventional film processing.
iii.
Minimize time for finalizing and interpreting RT result especially for critical
and urgent RT joint.
iv. No using of conventional RT film. Replaced with CRT imaging plate that can
re-use many time after previous shoot.

SAFETY
2.1

All radiographers shall be registered with AELB and operated within the allowable
permits.

2.2

All radiographers and assistant mandatory to wear film badge or TLD badge
everytime involve with radiography testing work.

2.3

The perimeter of boundary beyond which no radiation level is in excess of 0.75 mR/hr
(7.5 Sv/hr) shall be cordoned off with yellow rope (where practical) and warning
sign boards and flashing lights shall be placed at strategic locations.

2.4

The radiation level shall be monitored by using a calibrated radiation survey meter.

2.5

Understanding, familiarization and compliance to Care Ion Technologist Sd. Bhd.


radiation safety program which is approved by AELB is mandatory for each
technician involved in radiation exposure.

SURFACE PREPARATION
Weld or surface of object to be inspected shall be as follows:
3.1

Free from scale or weld slag.

3.2

Surface irregularity whenever possible is to be removed or dressed such that the


resulting radiographic image is not masked or confused with the image of any
relevant discontinuity that may be present.

3.3

Temporary tack welds to be ground.

METHOD STATEMENT COMBINATION OF


RADIOGRAPHIC TESTING USING LO-RAD AND
CRT EQUIPMENT

4.0

CIT/MS/LRCRT/001
0

3 of 5
19/09/2013

3.4

The finish surface may be flushed with the base material or may be have uniform
crown.

3.5

Methods or preparation shall be such that over heating or loss of material integrity
does not occur.

3.6

Surface shall satisfy the requirements of the applicable materials specifications, with
additional conditioning, if necessary, by any suitable process to a degree that surface
irregularities cannot mask or be confused with discontinuities.

RADIOGRAPHIC EQUIPMENT
4.1

Major RT Equipment
i.
ii.
iii.

4.2

4.3

Gamma projector
Windle cable
Guide tube

Lo-Rad Equipment
i.
ii.
iii.
iv.
v.
vi.

Mazel Mats with envelopes


Primary beam Mazel Mats with envelops
Mazel outer and standard inner guide tube
Collimator
Elipse Stand
Flash box

Computed Radiography Equipment


i.
ii.
iii.

5.0

DOC. NO.
REV.
PAGE
DATE

Posphor coated imaging plates


- (8x10 inch) & (14x17 inch)
HD-CR 35 NDT Scanner
Note book with CRT software

PRIOR TO WORK
5.1

RT equipment setting for RT Lo-Rad combined with CRT is same as preparation for
RT conventional (refer Radiography Testing Procedure).

5.2

For additional, weld or surface to be inspected will wrapped with Lo-Rad Mazel Mats
to achieve the safe distance 3-5 meters. See Figure 1.0.

METHOD STATEMENT COMBINATION OF


RADIOGRAPHIC TESTING USING LO-RAD AND
CRT EQUIPMENT

DOC. NO.
REV.
PAGE
DATE

CIT/MS/LRCRT/001
0

4 of 5
19/09/2013

Figure 1.0 : RT preparation with Lo-Rad equipment


6.0

DURING WORK
6.1

Same as Safety Procedure required by AELB during conventional RT work.

6.2

Refer to Radiographic Testing procedure and Computed Radiographic Testing


procedure..

6.3

Only qualified RT technician allowed to work in barricaded area. Outside barricaded


area is safe for non-radiation worker.

6.4

Once the exposure complete, the imaging plate will sliding onto the CRT scanner to
transfer the image into CRT software. May choose the option either to maintain the
image in imaging plate or erase it for re-use.

FIGURE 2.0 : Sliding imaging plate onto CRT scanner for image transfer to CRT software.

METHOD STATEMENT COMBINATION OF


RADIOGRAPHIC TESTING USING LO-RAD AND
CRT EQUIPMENT

7.0

DOC. NO.
REV.
PAGE
DATE

CIT/MS/LRCRT/001
0

AFTER WORK
7.1

All equipment shall housekeeping after completion of work.

5 of 5
19/09/2013