Answer ID
8913
Products
HMI (Visualization)
FactoryTalk View ME
RSView ME (Machine Edition)
Category
General
Date Created
02/07/2001 12:52 PM
Last Updated
02/18/2009 03:10 PM
Access Level
TechConnect
Prev. TN#
A8901
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.c ...
Details
When the development project files have been lost, some of the project
information can be recovered from the MER (Machine Edition Runtime)
file itself. However, the following cannot be recovered:
Parameter files
Alarm Setup
Datalog files
Macro files
Under some circumstances, the Tag Database cannot be recovered
either (described below under Tag Database recovery).
1 of 5
2009/05/08 3:57 PM
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.c ...
2 of 5
2009/05/08 3:57 PM
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.c ...
3 of 5
2009/05/08 3:57 PM
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.c ...
6.
7.
8.
9.
10.
Part B
10. Start up RSView Studio and create a blank project with the exact
same name as the MED file you are currently recovering. You will
need to do this in a separate directory than the recovered
project (Ex. C:\Projects\MED_ProjectName).
11. After the project has been created, close the project and
shutdown RSView Studio.
12. In Windows Explorer, locate the recovered project files folder
(Ex. C:\Temp\MED_ProjectName) and copy all of the files in it.
13. Paste the copied files into the project folder of step (10) (Ex.
C:\Projects\MED_ProjectName).
14. You will be asked if you wish to overwrite files. Click yes to all.
15. Start up RSView Studio and open the recovered MED file from
your new project folder. (Ex. C:\Projects\MED_ProjectName
\MED_ProjectName.med)
NOTE: If you performed Part A successfully, then proceed on to
step 17. If you did not perform Part A, then proceed to Removing
unrecoverable files.
16. Open up the Database Import & Export Wizard for RSView
Studio and import the CSV Tag Database from step (5) into your
recovered project (Ex. C:\Projects\MED_ProjectName\
MED_ProjectName-Tags.CSV)
17. Verify that the Tag Database is correct by looking at the Tag
Database Editor in RSView Studio.
Additional Information
If you had Macro, Parameter, or Datalog files added to your project, you
will encounter error messages when you run it. This is because there are
references to files that no longer exist. You will need to create these
files again and re-assign them (ex. Re-assign the startup macro for a
Display).
Also, objects with tag assignments may not work as they are right now.
You may need to open the display, delete the tag assignment and then
reassign the tag. Save the display. In most cases, you need only do this
4 of 5
2009/05/08 3:57 PM
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.c ...
5 of 5
2009/05/08 3:57 PM