Vous êtes sur la page 1sur 19

CONCEPTUAL DESIGN PLAN - REQUIRED INFORMATION CHECKLIST

House
Plans:

Floorplans
Elevations

Framingplans
Siteplan

Heating
System:

Forcedwarmair
Baseboard

CombustionAppliances
1.
2.
3.
4.

W0

Radiant

DraftType

VentilationStrategy:

DistributionStrategy:

BasicSystemType:

Exhaustonly (worksheetW1A)
Balancedcombinedwithforcedair (worksheetW1B)
Balanceddirectducted(worksheetW1C)

MethodofDealingwithPressureImbalances:

ControlSystem:

SpecialCustomerRequirements:

1.
2.
3.
4.
5.

VentilationEquipment:

1.
2.
3.
4.

OtherExhaustAppliances:(list)

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW0r08/10

DETAILEDDESIGNPLAN
ExhaustOnlySystem

W1A

FEATURES
Centralorlocalexhaustfans
Makeupairbyinfiltration

STOP

Forcedwarmairheatingsystem?
or

Willnotmeetventilation
distributionrequirements

NO

Smallcapacityrecirculationsystem?
YES

CAUTION

SpillageSusceptible
combustionappliance(s)?

YES

Mayrequiremakeupairsystem
interlockedtoventilationsystem
and/orexhaustappliances

NO
YES

Heatrecoveryrequired?

STOP
Usebalancedheatrecoverysystem

NO

UseworksheetW1BorW1C

Proceedwithdetaileddesign
9= required, X = notrequired

DETAILEDDESIGNTASKS:

worksheet#

Ventilationcapacity
Exhaustrequirements
Exhaust
requirements
Systemlayout,recirculationsystem(forcedwarmairorsmallcapacityrecirculation)
ImbalanceatTVCC(exhaustlargerthansupply)

orfieldtest

ImbalanceatCEC(onlyifspillagesusceptibleappliances)

orfieldtest

Checkmixedairtemperatureandpreheatersize(makeupairconnectedtoforcedair)
Systemlayout,grillesize,doorundercuts(centralexhaustfan)

Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)
Selectfanandsizeducts(centralfanifrequired)
Selectfanandsizeducts(smallcapacityrecirculationsystem,ifrequired)
Sizepoweredairintake/makeupairduct(ifrequired)

Sizefurnaceoutsideairduct(ifrequired)
Sizepassivemakeupairduct(ifrequired)

Describecontrolstrategy
Other

VentilationRecord W2
Ventilation Record W2
VentilationRecord
W2
plan
W3A
W3C
W4B
plan+
W5
W6A
W6B
W6B
W6C
W6D
W6E
W7

Other

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW1Ar08/10

DETAILEDDESIGNPLAN
BalancedSystem,CombinedwithForcedAir

W1B

Features
Ventilationsupplyairconnectedtoreturnductofforcedair
Dedicatedexhaustductingor"simplifiedconnection"

CAUTION

Ventilationsupplyconnectedto
forcedairwithoutheatrecovery?

YES

NO

Intakeairheatermayberequired.
Checkforcedairsystemmixedair
temperature&heatercapacity

HRV/ERVbasedsystem?

CAUTION
SpillageSusceptible
combustionappliance(s)?

Mayrequiremakeupairsystem
interlockedtoexhaustappliance(s)

YES

NO
Proceedwithdetaileddesign
9= required, X = not required

DETAILEDDESIGNTASKS:

worksheet #

Ventilationcapacity

VentilationRecord W2

Exhaustrequirements

VentilationRecord W2

Systemlayout,recirculationsystem(forcedwarmair)

ImbalanceatCEC(onlyifspillagesusceptibleappliances)

orFieldTest

AdjustHRV/ERVairflow

Checkmixedairtemperature,preheatersize(intakeorHRV/ERVconnectedtoforcedair)
Checkdeliveredairtemperature,selectintakeairheater(ifrequired)
Systemlayout,grillesize,doorundercuts(HRV/ERVorcentralfan)
Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)

plan+

Selectfanandsizeducts(HRV/ERVorcentralfanifrequired)
Sizepoweredairintakeduct(ifrequired)
Sizefurnaceoutsideairintakeduct(ifrequired)
Sizepassivemakeupairduct(ifrequired
Describecontrolstrategy

plan
W3C
W4A
W4B
W4C
W5
W6A
W6B
W6C
W6D
W6E
W7

Other

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW1Br08/10

DETAILEDDESIGNPLAN
BalancedSystem,DirectDucted

W1C

Features
HRV/ERVorexhaust+intakefanandheater
Directsupplyorexhaustfromallhabitablerooms
Exhaustsystemwith
intakefanandheater?

NO

HRV/ERVbasedsystem?

YES

Yes
Checkairdeliveryarrangement
(highorlowwall)against
heatercapacity

Checkairdelivery arrangement
(highorlowwall)against
HRV/ERVeffectiveness

Caution
SpillageSusceptible
combustionappliance(s)?

YES

Mayrequiremakeupairsystem
interlockedtoexhaustappliance(s)

NO
Proceedwithdetaileddesign

DETAILEDDESIGNTASKS:

9= required, X = not required

worksheet #

Ventilationcapacity

VentilationRecord W2

Exhaustrequirements
ImbalanceatCEC(onlyifspillagesusceptibleappliances)

VentilationRecord W
W2
2

AdjustHRV/ERVairflow(ifrequired)
Checkdeliveredairtemperature/selectintakeairheater(ifrequired)
Systemlayout,grillesize,doorundercuts(centralfanorHRV/ERV)

plan+

Selectfanandsizeducts(Singleductfans,rangehoods,bathfansetc.,ifrequired)

Selectfanandsizeducts(centralfan/HRV/E
Sizepoweredairintakeduct(ifrequired)
Sizepassiveairintake(ifrequired)

Describecontrolstrategy
Other

W3C
W4A
W4C
W5
W6A
W6B
W6C
W6E
W7

Other

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW1Cr08/10

RESIDENTIALMECHANICALVENTILATIONRECORD

(exhaust)EQUIPMENT

ADDITIONAL

Location:

Manufacturer/Model:
DesignAirflow

cfmhigh

HRV/ERV
%SensibleEfficiency@0C
HRV/ERV
%SensibleEfficiency@25C
1 Location:
Manufacturer/Model:
2 Location:
Manufacturer/Model:
3 Location:
Manufacturer/Model:
4 Location:
Manufacturer/Model:

cfm
cfm
cfm

cfm

cfm

cfm

cfm

TVC
TVC
TVC
TVC

Sones
HVI
Sones
HVI
Sones
HVI
Sones
HVI

LOCATION

BUILDER
DESIGNER

Supplyintake3'fromotherexhaust
TVCsystemSUPPLYairflowmeasured
cfmHigh

cfmLow
TVCsystemEXHAUSTairflowmeasured

cfmHigh

cfmLow

HVIrated
cfmlow

watts
watts

Name:

HRAI#:

Address:
P.C.

City:
Phone:
Fax:
EmailAddress:
Icertifythisventilationsysteminstalltobeinaccordancewith:
CSAF326M91
R2000
Signature:
Date:

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

MEASURED

MinimumIntermittentExhaust
@ 100 cfm =

@ 50 cfm =

Total

W2
H

TVCSYSTEMS

SYSTEM

TVC

E
F

Kitchen(s)
Bathroom(s)

Roll#:
Permit#:
Lot&Plan:
Civicaddress:
HouseID#:
Name:
Address:
City:
P.C.

Phone:
Fax:
EmailAddress:
Name:
HRAI#:

Address:
P.C.

City:
Phone:
Fax:
EmailAddress:
Other#
Icertifythisventilationsystemdesigntobeinaccordancewith:
CSAF326M91
R2000
Signature:
Date:
ControlsFunctioning
Fansoperatingandclean
FiltersClean
Flowmeasuringstations
DampersAccessible
Insulatedductssealed
Drainloopandconnection
Labelsupply/exhausthood
Distributiontoallhabitablerooms(nonforcedair)
Forcedairsystem
Continuousmode
Interlocked
Kitchenexh.40"torange
Kitchenintakegreasefilter
Exhaust4"abovegrade
Supply18"abovegrade
Supplyintake6'fromexhaust(recommended)

INSTALLER

CAPACITY(TVC)
Continuous

EXHAUSTCAPACITY

ForcedAir
NonForcedair
Gas
Oil
Electric
Other
NoCombustionAppliances
NoDepressurizationlimit
SolidFuel(includingFireplaces)
5paDepresslimit
DirectVent(sealedcombustion)
NoDepLimit
Pascalslimit
PositiveVentingInducedDraft
NaturalDraftorBVentAtmospheric
5padepresslimit
LowestDepressurizationLimit_________Pa.
(150cfmdefault)
ClothesDryer(s)
owndraftCookTop
D

(220cfmdefault)
Other(exhaust)
(over150cfm)
Depressurizationtest/Calc.Required?
Yes
No
Bsmt&MasterBedroom

cfm
@ 20 cfm
OtherBedrooms

@ 10 cfm

cfm

@ 10 cfm

cfm
Bathrooms&Kitchens
OtherHab.Rooms

@ 10 cfm

cfm
TotalVentilationCapacity(TVC)
cfm

MinimumContinuousExhaust
Kitchen(s)
@ 60 cfm =

cfm
Bathroom(s)
@ 20 cfm =

cfm
Total
cfm

Intermittent

HEATINGSYSTEM/
TOTALVENTILATION

EQUIPMENT COMBUSTIONAPPLIANCES

EXHAUST

INSTALLATIONCHECKLIST

ForCertificationofDesignandPerformanceofResidentialVentilationSystems

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW2r08/10

IMBALANCE@TVCC(TotalVentilationCapacityCondition)
forsystemswithmoreexhaustthansupply@TVCC

W3A
line#

1.FLOORAREA
TotalFloorArea
(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)

ft2

301

2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH

Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH

HouseACH50
oractualtest_________

302

3.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMIT
Ifspillagesusceptible,=5pa.

flowfactor=0.022

Ifnonspillagesusceptible,=10pa

flowfactor=0.037

pa

DepressurizationLimit@TVCC

FlowFactor

303

304

4.ALLOWABLENETEXHAUST
FloorArea(301)________ft2xACH50(302)________xFlowFactor(304)________=

305

AllowableNetExhaust@TVCC

cfm

TVCCExhaust

cfm

306

cfm

307

cfm

308

cfm

cfm

RequiredMakeUpAirflow@TVCC

cfm

AtDepressurizationLimit(line303)

pa

5.ACTUALNETEXHAUST
minus
TVCCSupply

=equals
ActualNetExhaust@TVCC
Note:Ifsupplyisgreaterthanexhaust,useworksheet#W3B

6.REQUIREDMAKEUPAIRFLOW
ActualNetExhaust@TVCC(line308)
minus
AllowableNetExhaust@TVCC(line305)

Note:
IfActual NetExhaust
islessthan Allowable
NetExhaustnoaction
isrequired.

=equals
309

7.DESCRIPTIONOFMAKEUPAIRSYSTEM

8.ONSITETESTDEPRESSURIZATIONTEST

Required

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

NotRequired

310

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW3Ar08/10

IMBALANCE@TVCC(TotalVentilationCapacityCondition)
forsystemswithmoresupplythanexhaust@TVCC
1.FLOORAREA

W3B
line#

TotalFloorArea

ft

301

(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)

2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH

Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH

HouseACH50
oractualtest_________

302

3.ALLOWABLENETSUPPLY
FloorArea(301)__________ft2xACH50(302)_________x0.037=
AllowableNetSupply@TVCC

cfm

311

cfm

312

cfm

313

cfm

314

4.ACTUALNETEXHAUST
TVCCSupply
minus
TVCCExhaust
=equals
ActualNetSupply@TVCC

Note:Ifexhaustisgreaterthansupply,useworksheet#W3A

5.REQUIREDRELIEFAIRFLOW

ActualNetSupply@TVCC(line314)
minus
AllowableNetSupply@TVCC(line311)

Note:
IfActual NetSupply
islessthan Allowable
NetSupplynoaction
isrequired.

cfm

cfm

cfm

= equals
=equals
RequiredReliefAirflow@TVCC

315

6.DESCRIPTIONOFRELIEFAIRSYSTEM

7.ONSITEPRESSURIZATIONTEST

Required

NotRequired

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

316

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW3Br08/10

W3C

IMBALANCE@CEC(CriticalExhaustCondition)
forsystemswithspillagesusceptiblecombustionappliances
1.FLOORAREA

TotalFloorArea

line#

ft2

301

(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)

2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH
Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH
oractualtest_________

HouseACH50

302

3.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMIT
OTHERLIMIT=flowfactor
5to10pa0.022
10to20pa0.036
20to30pa0.059
30to40pa0.080
40to50pa0.101
50andover0.143

Ifspillagesusceptible=5pa,

pa

DepressurizationLimit@CEC

flowfactor=0.022

320

if"other"appliance,limit=

manufacturer'srating=_____pa

FlowFactor

forflowfactorusechartatleft

321

4.ALLOWABLENETEXHAUST
FloorArea(301)________ft2xACH50(302)________xFlowFactor(321)________=
AllowableNetExhaust@CEC

cfm

322

TVCCExhaust
minus
TVCCSupply
+plus

cfm

323

cfm

324

DryerExhaust(default150)

cfm

325

cfm

325a

cfm

325b

+plusLargeExhaustDeviceover150cfm(c)
=equals

cfm

325c

ActualNetExhaust@CEC

cfm

326

ActualNetExhaust@CEC(line326)
minus
AllowableNetExhaust@CEC(line322)
=equals

cfm

cfm

RequiredMakeUpAirflow@CEC

cfm

@DepressurizationLimit(line320)

pa

5.ACTUALNETEXHAUST

+plusLargeExhaustDeviceover150cfm(a)
+plusLargeExhaustDeviceover150cfm(b)

(Listdevicesover150CFM)

6.REQUIREDMAKEUPAIRFLOW
Note:
IfActual NetExhaust
islessthan Allowable
NetExhaustnoaction
isrequired.

327

7.DESCRIPTIONOFMAKEUPAIRSYSTEM

8.ONSITETESTDEPRESSURIZATIONTEST

Required

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

NotRequired

328

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW3Cr08/10

W4A

HRVAIRFLOWADJUSTMENTS
1.EQUIPMENT

line#

Make:
Model:

2.LOWTEMPERATURECORRECTION
TemperatureZone(note1)

401

LowTemperatureVentilationReduction(note2)

402

LowTemperatureAdjustmentFactor(note3)

403

xtimes

cfm

404

cfm

405

cfm

406

cfm

cfm

AdjustedDesignGrossSupplyAirflow

cfm

406A

AdjustedDesignGrossSupplyAirflow(406A)
divideby
TotalVentilationCapacity(404)
=equals

cfm

cfm

AirflowAdjustmentFactor

TotalVentilationCapacity(TVCfromW2)
=equals
LowTemperatureCorrectedVentilationRate
Notes:
1.frommapinthe"TablesandCharts"sectionoftheHRAIventilationmanual
2.lowestofsupplyorexhaustfromHRV/ERVmanufacturerspecsheet
3.fromtableinthe"TablesandCharts"sectionoftheHRAIventilationmanual

3.AIRFLOWADJUSTMENTFACTOR
DesignGrossSupplyAirflow(note1)
minus
NetSupplyAirflow
+plus
LowTemperatureCorrectedVentilationRate(405)
=equals

407

Notes:
1)theGROSSSUPPLYAIRFLOWfromHRV/ERVmanufacturerspecsheetwhich
correspondstothelowestNETSUPPLYAIRFLOWthatmeetsorexceeds
thecorrespondingcorrectedventilationratefromline405

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW4Ar08/10

MIXEDAIRTEMPERATUREFORCEDWARMAIRSYSTEMS

W4B
line#

1.HRVAIRDELIVERYTEMPERATURE
JobLocation:

DT=

HRV/ERVApparentSensibleEffectiveness

408

OutdoorDesignTemperature(ODT)

409

410

cfm

411

cfm

412

413

ODT+[(21ODT)x%HRV/ERVeff.]
100
AirDeliveryTemperature(DT)
Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesand

IfHRV/ERVnotusedDT=ODT

ChartssectionoftheHRAIventilationmanual.

2.PERCENTAGEHOUSEAIR
OutdoorAirflow(OAF)(Supply)

%HA= RAFOAF
RAF

ReturnAirflow(RAF)

x100

PercentageHouseAir(%HA)
Note:useformulaaboveorpercentage
houseairchartfoundintheTablesandChartssectionoftheHRAIventilationmanual

3.MIXEDAIRTEMPERATURE

MAT=

AirDeliveryTemperature(DT)(410)

PercentageHouseAir(%HA)(413)

MixedAirTemperature(MAT)

MinimumMixedAirTemperature

15.5

RAT[(RATDT)x(100%HA)]
100

414

Note:useformulaaboveormixedairtemperaturechart
foundintheTablesandChartssectionoftheHRAIventilationmanual

4.PREHEATING
TR=15.5MAT

minus
C

MixedAirTemperature(MAT)(414)
=equals

TemperatureRise(TR)

C
415

Note:IfTR(418)isanegativenumbernoheaterisrequired.

ReturnAirflow(RAF)(412)

cfm

xtimes

TemperatureRise(TR)(415)

Preheater=TRxRAFx0.57

xtimes

constant

0.57

=equals

Note:Preheateronlyrequiredifmixedairtemperatureisbelow15.5C

PreheaterSize

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

watts

416

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW4Br08/10

DELIVEREDAIRTEMPERATUREDIRECTDUCTEDSYSTEMSORMAKEUPAIRSYSTEMS

W4C
line#

1.HRVAIRDELIVERYTEMPERATURE
JobLocation
HRV/ERVApparentSensibleEffectiveness

408

OutdoorDesignTemperature(ODT)

409

AirDeliveryTemperature(DT)

410

417

418

cfm

419

watts

420

DT=

ODT+[(21ODT)x%HRV/ERVeff.]
100

Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesand

IfHRV/ERVnotusedDT=ODT

ChartssectionoftheHRAIventilationmanual.

2.HEATING
DesiredDeliveredAirTemperature(DDT)
Delivered AirTemperature
minimums:

minus
AirDeliveryTemperature(DT)(410)

highwalldiffusers=12C
floordiffusers=15.5C

=equals
TemperatureRise(TR)

Note:IfTR(418)isanegativenumbernoheaterisrequired.

TemperatureRise(TR)(418)
xtimes

TR=DDTDT

SystemAirflow(SAF)
xtimes
constant

0.57

=equals

Heater=TRXSAFx0.57
HeaterType

HeaterSize

HRVPostheater

Directoutsideairheater

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW4Cr08/10

SYSTEMLAYOUTGRILLESIZEDOORUNDERCUTS
SYSTEM:

Column

Balancedventilation

ROOMNAME

REQUIREDAIRFLOW

ANDTYPE
(typeaorb)

(CSAF326table1)
Supply
Exhaust
(cfm)
(cfm)
2
3

DESIGNAIRFLOW
(aspersystemlayout)

W5

CentralExhaust

Smallcapacityrecirculation

AIRFLOW

ADJUSTEDAIRFLOW

ADJUST.

(designairflowXcol.6)
Exhaust
Supply
(cfm)
(cfm)
8
7

Supply
(cfm)
4

Exhaust
(cfm)
5

FACTOR
(line407)
6

GRILLE/DIFFUSER

DOOR
UNDERCUT

TYPE

SIZE

10

(inches)
11

TOTALCFM

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW5r08/10

DUCTSIZINGSINGLEDUCT

W6A

2.SYSTEMTOTALEFFECTIVELENGTH

1.EQUIPMENT

Fan#.
Make:
Model:

Designairflow:
EquipmentE.S.P.:

"dia.@

cfm
"w.c.

ft

3.DUCTSIZE

ft

ActualLengthDuctRun:
Equivalentlengthoutsidehood:

w.c.

ft
ft
ft
ft
ft
ft
ft
ft
ft

TotalEffectiveLength:

Sketch

1.EQUIPMENT

2.SYSTEMTOTALEFFECTIVELENGTH

Fan#.

ActualLengthDuctRun:
Equivalentlengthoutsidehood:

Make:
Model:
Designairflow:
EquipmentE.S.P.:

"dia.@

cfm
"w.c.

ft

3.DUCTSIZE

ft

w.c.
TotalEffectiveLength:

ft
ft
ft
ft
ft
ft
ft
ft
ft

Sketch

Prepared By:

HRAI#:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW6Ar08/10

DUCTSIZINGBRANCHEDSYSTEM
1.EQUIPMENT
Model:
System:

W6B

2.DESIGNCONDITIONS

3.OUTSIDEDUCTRUNSIZING
Airflow:

cfm

DesignAirflow:

EquipmentE.S.P.:

cfm

in.w.c.@

cfm

Diameter

in

Pressureloss,outsideduct:

"w.c.

ft

Availablestaticpressure:

"w.c.

Outsideducteffectivelength

Note:Theavailablestaticpressureistobeusedtoselectallductsizesinthefollowingsections4&5

4.BRANCHDUCTSIZING

RunID
Location

Airflow:
ActualLength

Elbowsx__

Eff.Length
Diameter
Rect.Size
RunID
Location
Airflow:
ActualLength

Elbowsx__

ActualLength

ActualLength

Elbowsx__

Elbowsx__

Elbowsx__

ft Eff.Length
in Diameter
x

Rect.Size
RunID
Location
cfm Airflow:

ActualLength

ActualLength

Elbowsx__

Elbowsx__

ft Eff.Length
in Diameter
x

Rect.Size

cfm

ft Eff.Length
in Diameter
x

Rect.Size

EFFECTIVELENGTH
cfm
cfm
cfm
cfm
cfm
cfm

ft
in

Rect.Size
RunID
Location
cfm Airflow:

Elbowsx__

AIRFLOW

TRUNKI.D.

ft Eff.Length
in Diameter

ActualLength

ft Eff.Length
in Diameter

x
5.TRUNKDUCTDESIGN

cfm

ActualLength

Rect.Size
RunID
Location
cfm Airflow:

RunID
Location
cfm Airflow:

RunID
Location
cfm Airflow:

ft Eff.Length
in Diameter

Eff.Length
Diameter
Rect.Size

RunID
Location
cfm Airflow:

DIAMETER

RECTANGULARSIZE
in

ft

in

ft

in

ft

in

ft

in

ft

in

HRAI #:

Job Name:

Signature:

Date:

Job #:

Rect.Size

ft

Prepared By:

ft
in

x
x
x
x
x
x

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW6Br08/10

DUCTSIZINGPOWEREDINTAKE/MAKEUPAIR
1.EQUIPMENT
Fan:

Heater:

W6C

3.TOTALEFFECTIVELENGTH
Make:

ActualLengthDuctRun:

ft

Model:

Equivalentlengthoutsidehood:

ft

ft

Make:

ft

Model:

ft

ft

ft

ft

ft

ft

Designairflow

cfm

2.OPERATINGPOINT
EquipmentESP:

"w.c.

minus
Heaterstaticpressuredrop:
equals=

"w.c.

Availablestaticpressure:

"w.c. 4.DUCTSIZE

TotalEffectiveLength:

ft

ft

"w.c.

"dia@:

Sketch

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW6Cr
08/10

DUCTSIZINGFURNACEOUTSIDEAIRINTAKE
1.REQUIREDAIRFLOW
Systemoperatingspeed
Airflow:

W6D

3.TOTALEFFECTIVELENGTH
ActualLengthDuctRun:
Equivalentlengthoutsidehood:

high
low

cfm

ft

ft

ft

ft

ft

ft

ft

2.SUCTIONPRESSURE
Note:Useactualstaticpressureat
connectionpointifpossible
Ifpressure isunknownuse.1"w.c.for
highspeedand.05in.w.c.forlowspeed

highspeed

"w.c.

lowspeed

"w.c.

ft
ft
ft

TotalEffectiveLength:

ft

ft

4.INTAKEDUCTSIZE
speed

high
low

"dia@:

"w.c.

Sketch

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW6Dr08/10

DUCTSIZINGPASSIVEMAKEUP/RELIEFAIRDUCTSIZING
1.PRESSURE

W6E

3.TOTALEFFECTIVELENGTH
ft

ActualLengthDuctRun:

ft

Equivalentlengthoutsidehood:

Depressurization/pressurization

Limit:

Pa.

2.AIRFLOW
test

depressurizationatCEC

(pg220Manual)excessiveflowfactor

Pa.

timesx
netexhaustatCEC
equals=

Designairflow

cfm
cfm

ft
ft
ft
ft

ft

ft

ft

ft
ft
ft

TotalEffectiveLength:

OR
calculation
4.DUCTSIZE
form: W3A
W3B
W3C
Designairflow:

cfm

"dia@:

w.c

Sketch

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW6Er08/10

W7

VENTILATION SYSTEM CONTROLS


VENTILATIONDEVICE

CONTROLSTRATEGY

CONTROLDEVICE

1.

2.

3.

4.

5.

6.

7.

Prepared By:

HRAI #:

Job Name:

Signature:

Date:

Job #:

Official Use:

CopyrightHRAIResidentialVentilationWORKSHEETW7r08/10

DEPRESSURIZATIONTESTREPORT
Note:Thistestisforcodecomplianceoftheventilationsystemonly.
Thisisnotacombustionsystemtestorabackspillagetest.

BUILDER/HOUSE

EXHAUSTAPPLIANCES
DescribeAllExhaustAppliances

1)
capacity
2)
capacity
3)
capacity

cfm(L/s)

OnatTVCC?

OnatCEC?

City:

P.C.

Phone:
cfm(L/s)

OnatTVCC?

OnatCEC?

Fax:

EmailAddress:

MEASUREMENTS
cfm(L/s)

OnatTVCC?

Dateoftest:

OnatCEC?

4)
capacity

cfm(L/s)

OnatTVCC?

OnatCEC?

5)
capacity

cfm(L/s)

OnatTVCC?

OnatCEC?

6)
capacity

HouseID#:

Name:
Address:

mm/dd/yy

Note: Testtobecarriedoutwhenhouseissubstantiallycomplete

Wind:

km/h(mph)

Note: Windconditionsshouldbelessthan15km/h(9mph)

SEEOVERFORPROCEDUREDESCRIPTION
cfm(L/s)

OnatTVCC?

OnatCEC?

COMBUSTIONAPPLIANCES
1.

Starting"Rest"Pressure

Pa (a)

Pressure@TVCC
Pressure@CEC

Pa (b)

Ending"Rest"Pressure

Pa (d)

Pa (c)

Pa

DepressurizationLimit
2.

DepressurizationLimit

Pa

DepressurizationLimit

Pa

DepressurizationLimit

Pa

DepressurizationLimit

Pa

3.

4.

DEPRESSURIZATION@TVCC
(b) minus (a) =
Pa (e)
(b) minus (d) =
Pa (f)
Pa

Largestof(e)or(f)=Dep.@TVCC
Note:Depressurizationlimitfromleft,butnomorethan10Pa.

5.

DEPRESSURIZATION@CEC
(c) minus (a) =
Pa (g)
(c) minus (d) =
Pa (h)
Pa

Largestof(g)or(h)=Dep.@CEC
Pa

LowestDepressurizationLimit

TESTINSTRUMENT

Note:IfanyexhaustequipmentrequiredtorunattheCECisnotinstalled
itmustbesimulatedandtheflowverifiedbyflowmeasurementstation
orequivelant

Make:
Type:

TESTTESULTS
Note:Thetestmustbeperformedusinganinstrumentcapableof

Thedwellingunitandsystemsatthetimeoftest:

measuring0to60Pa.rangewithasensitivityof2Pa.

in.w.c. 0.004 0.008 0.01 0.016


Pa
3
4
1
2

0.02

0.04

0.20

10

50

TESTFIRMINFORMATION
JobName:

JobNumber:

Name:

doesnotconform

tothedepressurizationrequirementsofCSAF326M91.

CERTIFICATION
ICERTIFYTHATTHETESTHASBEENPERFORMEDINACCORDANCEWITHTHETEST
PROCEDURESETOUTINCSAF326M91PARAGRAPH11.2.2.a(i)AND11.2.2b(i)

Date:

Address:

Tel:

conforms

mm/dd/yy

Tel:
PostalCode:
Fax:

Name:
HRAICertification#:
Signature:

CopyrightHRAIResidentialVentilationr08/10

Vous aimerez peut-être aussi