Heating
System:
Forcedwarmair
Baseboard
CombustionAppliances
1.
2.
3.
4.
W0
Radiant
DraftType
VentilationStrategy:
DistributionStrategy:
BasicSystemType:
Exhaustonly (worksheetW1A)
Balancedcombinedwithforcedair (worksheetW1B)
Balanceddirectducted(worksheetW1C)
MethodofDealingwithPressureImbalances:
ControlSystem:
SpecialCustomerRequirements:
1.
2.
3.
4.
5.
VentilationEquipment:
1.
2.
3.
4.
OtherExhaustAppliances:(list)
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW0r08/10
DETAILEDDESIGNPLAN
ExhaustOnlySystem
W1A
FEATURES
Centralorlocalexhaustfans
Makeupairbyinfiltration
STOP
Forcedwarmairheatingsystem?
or
Willnotmeetventilation
distributionrequirements
NO
Smallcapacityrecirculationsystem?
YES
CAUTION
SpillageSusceptible
combustionappliance(s)?
YES
Mayrequiremakeupairsystem
interlockedtoventilationsystem
and/orexhaustappliances
NO
YES
Heatrecoveryrequired?
STOP
Usebalancedheatrecoverysystem
NO
UseworksheetW1BorW1C
Proceedwithdetaileddesign
9= required, X = notrequired
DETAILEDDESIGNTASKS:
worksheet#
Ventilationcapacity
Exhaustrequirements
Exhaust
requirements
Systemlayout,recirculationsystem(forcedwarmairorsmallcapacityrecirculation)
ImbalanceatTVCC(exhaustlargerthansupply)
orfieldtest
ImbalanceatCEC(onlyifspillagesusceptibleappliances)
orfieldtest
Checkmixedairtemperatureandpreheatersize(makeupairconnectedtoforcedair)
Systemlayout,grillesize,doorundercuts(centralexhaustfan)
Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)
Selectfanandsizeducts(centralfanifrequired)
Selectfanandsizeducts(smallcapacityrecirculationsystem,ifrequired)
Sizepoweredairintake/makeupairduct(ifrequired)
Sizefurnaceoutsideairduct(ifrequired)
Sizepassivemakeupairduct(ifrequired)
Describecontrolstrategy
Other
VentilationRecord W2
Ventilation Record W2
VentilationRecord
W2
plan
W3A
W3C
W4B
plan+
W5
W6A
W6B
W6B
W6C
W6D
W6E
W7
Other
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW1Ar08/10
DETAILEDDESIGNPLAN
BalancedSystem,CombinedwithForcedAir
W1B
Features
Ventilationsupplyairconnectedtoreturnductofforcedair
Dedicatedexhaustductingor"simplifiedconnection"
CAUTION
Ventilationsupplyconnectedto
forcedairwithoutheatrecovery?
YES
NO
Intakeairheatermayberequired.
Checkforcedairsystemmixedair
temperature&heatercapacity
HRV/ERVbasedsystem?
CAUTION
SpillageSusceptible
combustionappliance(s)?
Mayrequiremakeupairsystem
interlockedtoexhaustappliance(s)
YES
NO
Proceedwithdetaileddesign
9= required, X = not required
DETAILEDDESIGNTASKS:
worksheet #
Ventilationcapacity
VentilationRecord W2
Exhaustrequirements
VentilationRecord W2
Systemlayout,recirculationsystem(forcedwarmair)
ImbalanceatCEC(onlyifspillagesusceptibleappliances)
orFieldTest
AdjustHRV/ERVairflow
Checkmixedairtemperature,preheatersize(intakeorHRV/ERVconnectedtoforcedair)
Checkdeliveredairtemperature,selectintakeairheater(ifrequired)
Systemlayout,grillesize,doorundercuts(HRV/ERVorcentralfan)
Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)
plan+
Selectfanandsizeducts(HRV/ERVorcentralfanifrequired)
Sizepoweredairintakeduct(ifrequired)
Sizefurnaceoutsideairintakeduct(ifrequired)
Sizepassivemakeupairduct(ifrequired
Describecontrolstrategy
plan
W3C
W4A
W4B
W4C
W5
W6A
W6B
W6C
W6D
W6E
W7
Other
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW1Br08/10
DETAILEDDESIGNPLAN
BalancedSystem,DirectDucted
W1C
Features
HRV/ERVorexhaust+intakefanandheater
Directsupplyorexhaustfromallhabitablerooms
Exhaustsystemwith
intakefanandheater?
NO
HRV/ERVbasedsystem?
YES
Yes
Checkairdeliveryarrangement
(highorlowwall)against
heatercapacity
Checkairdelivery arrangement
(highorlowwall)against
HRV/ERVeffectiveness
Caution
SpillageSusceptible
combustionappliance(s)?
YES
Mayrequiremakeupairsystem
interlockedtoexhaustappliance(s)
NO
Proceedwithdetaileddesign
DETAILEDDESIGNTASKS:
worksheet #
Ventilationcapacity
VentilationRecord W2
Exhaustrequirements
ImbalanceatCEC(onlyifspillagesusceptibleappliances)
VentilationRecord W
W2
2
AdjustHRV/ERVairflow(ifrequired)
Checkdeliveredairtemperature/selectintakeairheater(ifrequired)
Systemlayout,grillesize,doorundercuts(centralfanorHRV/ERV)
plan+
Selectfanandsizeducts(Singleductfans,rangehoods,bathfansetc.,ifrequired)
Selectfanandsizeducts(centralfan/HRV/E
Sizepoweredairintakeduct(ifrequired)
Sizepassiveairintake(ifrequired)
Describecontrolstrategy
Other
W3C
W4A
W4C
W5
W6A
W6B
W6C
W6E
W7
Other
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW1Cr08/10
RESIDENTIALMECHANICALVENTILATIONRECORD
(exhaust)EQUIPMENT
ADDITIONAL
Location:
Manufacturer/Model:
DesignAirflow
cfmhigh
HRV/ERV
%SensibleEfficiency@0C
HRV/ERV
%SensibleEfficiency@25C
1 Location:
Manufacturer/Model:
2 Location:
Manufacturer/Model:
3 Location:
Manufacturer/Model:
4 Location:
Manufacturer/Model:
cfm
cfm
cfm
cfm
cfm
cfm
cfm
TVC
TVC
TVC
TVC
Sones
HVI
Sones
HVI
Sones
HVI
Sones
HVI
LOCATION
BUILDER
DESIGNER
Supplyintake3'fromotherexhaust
TVCsystemSUPPLYairflowmeasured
cfmHigh
cfmLow
TVCsystemEXHAUSTairflowmeasured
cfmHigh
cfmLow
HVIrated
cfmlow
watts
watts
Name:
HRAI#:
Address:
P.C.
City:
Phone:
Fax:
EmailAddress:
Icertifythisventilationsysteminstalltobeinaccordancewith:
CSAF326M91
R2000
Signature:
Date:
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
MEASURED
MinimumIntermittentExhaust
@ 100 cfm =
@ 50 cfm =
Total
W2
H
TVCSYSTEMS
SYSTEM
TVC
E
F
Kitchen(s)
Bathroom(s)
Roll#:
Permit#:
Lot&Plan:
Civicaddress:
HouseID#:
Name:
Address:
City:
P.C.
Phone:
Fax:
EmailAddress:
Name:
HRAI#:
Address:
P.C.
City:
Phone:
Fax:
EmailAddress:
Other#
Icertifythisventilationsystemdesigntobeinaccordancewith:
CSAF326M91
R2000
Signature:
Date:
ControlsFunctioning
Fansoperatingandclean
FiltersClean
Flowmeasuringstations
DampersAccessible
Insulatedductssealed
Drainloopandconnection
Labelsupply/exhausthood
Distributiontoallhabitablerooms(nonforcedair)
Forcedairsystem
Continuousmode
Interlocked
Kitchenexh.40"torange
Kitchenintakegreasefilter
Exhaust4"abovegrade
Supply18"abovegrade
Supplyintake6'fromexhaust(recommended)
INSTALLER
CAPACITY(TVC)
Continuous
EXHAUSTCAPACITY
ForcedAir
NonForcedair
Gas
Oil
Electric
Other
NoCombustionAppliances
NoDepressurizationlimit
SolidFuel(includingFireplaces)
5paDepresslimit
DirectVent(sealedcombustion)
NoDepLimit
Pascalslimit
PositiveVentingInducedDraft
NaturalDraftorBVentAtmospheric
5padepresslimit
LowestDepressurizationLimit_________Pa.
(150cfmdefault)
ClothesDryer(s)
owndraftCookTop
D
(220cfmdefault)
Other(exhaust)
(over150cfm)
Depressurizationtest/Calc.Required?
Yes
No
Bsmt&MasterBedroom
cfm
@ 20 cfm
OtherBedrooms
@ 10 cfm
cfm
@ 10 cfm
cfm
Bathrooms&Kitchens
OtherHab.Rooms
@ 10 cfm
cfm
TotalVentilationCapacity(TVC)
cfm
MinimumContinuousExhaust
Kitchen(s)
@ 60 cfm =
cfm
Bathroom(s)
@ 20 cfm =
cfm
Total
cfm
Intermittent
HEATINGSYSTEM/
TOTALVENTILATION
EQUIPMENT COMBUSTIONAPPLIANCES
EXHAUST
INSTALLATIONCHECKLIST
ForCertificationofDesignandPerformanceofResidentialVentilationSystems
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW2r08/10
IMBALANCE@TVCC(TotalVentilationCapacityCondition)
forsystemswithmoreexhaustthansupply@TVCC
W3A
line#
1.FLOORAREA
TotalFloorArea
(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)
ft2
301
2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH
Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH
HouseACH50
oractualtest_________
302
3.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMIT
Ifspillagesusceptible,=5pa.
flowfactor=0.022
Ifnonspillagesusceptible,=10pa
flowfactor=0.037
pa
DepressurizationLimit@TVCC
FlowFactor
303
304
4.ALLOWABLENETEXHAUST
FloorArea(301)________ft2xACH50(302)________xFlowFactor(304)________=
305
AllowableNetExhaust@TVCC
cfm
TVCCExhaust
cfm
306
cfm
307
cfm
308
cfm
cfm
RequiredMakeUpAirflow@TVCC
cfm
AtDepressurizationLimit(line303)
pa
5.ACTUALNETEXHAUST
minus
TVCCSupply
=equals
ActualNetExhaust@TVCC
Note:Ifsupplyisgreaterthanexhaust,useworksheet#W3B
6.REQUIREDMAKEUPAIRFLOW
ActualNetExhaust@TVCC(line308)
minus
AllowableNetExhaust@TVCC(line305)
Note:
IfActual NetExhaust
islessthan Allowable
NetExhaustnoaction
isrequired.
=equals
309
7.DESCRIPTIONOFMAKEUPAIRSYSTEM
8.ONSITETESTDEPRESSURIZATIONTEST
Required
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
NotRequired
310
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW3Ar08/10
IMBALANCE@TVCC(TotalVentilationCapacityCondition)
forsystemswithmoresupplythanexhaust@TVCC
1.FLOORAREA
W3B
line#
TotalFloorArea
ft
301
(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)
2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH
Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH
HouseACH50
oractualtest_________
302
3.ALLOWABLENETSUPPLY
FloorArea(301)__________ft2xACH50(302)_________x0.037=
AllowableNetSupply@TVCC
cfm
311
cfm
312
cfm
313
cfm
314
4.ACTUALNETEXHAUST
TVCCSupply
minus
TVCCExhaust
=equals
ActualNetSupply@TVCC
Note:Ifexhaustisgreaterthansupply,useworksheet#W3A
5.REQUIREDRELIEFAIRFLOW
ActualNetSupply@TVCC(line314)
minus
AllowableNetSupply@TVCC(line311)
Note:
IfActual NetSupply
islessthan Allowable
NetSupplynoaction
isrequired.
cfm
cfm
cfm
= equals
=equals
RequiredReliefAirflow@TVCC
315
6.DESCRIPTIONOFRELIEFAIRSYSTEM
7.ONSITEPRESSURIZATIONTEST
Required
NotRequired
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
316
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW3Br08/10
W3C
IMBALANCE@CEC(CriticalExhaustCondition)
forsystemswithspillagesusceptiblecombustionappliances
1.FLOORAREA
TotalFloorArea
line#
ft2
301
(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)
2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'S
TightR20000.5ACH
TypicalR20001.0ACH Prairies/North(new)1.0 ACH
Atlantic(new)1.5 ACH
Otherprovinces(new)1.4 ACHOlderhomes2.5 ACH
oractualtest_________
HouseACH50
302
3.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMIT
OTHERLIMIT=flowfactor
5to10pa0.022
10to20pa0.036
20to30pa0.059
30to40pa0.080
40to50pa0.101
50andover0.143
Ifspillagesusceptible=5pa,
pa
DepressurizationLimit@CEC
flowfactor=0.022
320
if"other"appliance,limit=
manufacturer'srating=_____pa
FlowFactor
forflowfactorusechartatleft
321
4.ALLOWABLENETEXHAUST
FloorArea(301)________ft2xACH50(302)________xFlowFactor(321)________=
AllowableNetExhaust@CEC
cfm
322
TVCCExhaust
minus
TVCCSupply
+plus
cfm
323
cfm
324
DryerExhaust(default150)
cfm
325
cfm
325a
cfm
325b
+plusLargeExhaustDeviceover150cfm(c)
=equals
cfm
325c
ActualNetExhaust@CEC
cfm
326
ActualNetExhaust@CEC(line326)
minus
AllowableNetExhaust@CEC(line322)
=equals
cfm
cfm
RequiredMakeUpAirflow@CEC
cfm
@DepressurizationLimit(line320)
pa
5.ACTUALNETEXHAUST
+plusLargeExhaustDeviceover150cfm(a)
+plusLargeExhaustDeviceover150cfm(b)
(Listdevicesover150CFM)
6.REQUIREDMAKEUPAIRFLOW
Note:
IfActual NetExhaust
islessthan Allowable
NetExhaustnoaction
isrequired.
327
7.DESCRIPTIONOFMAKEUPAIRSYSTEM
8.ONSITETESTDEPRESSURIZATIONTEST
Required
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
NotRequired
328
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW3Cr08/10
W4A
HRVAIRFLOWADJUSTMENTS
1.EQUIPMENT
line#
Make:
Model:
2.LOWTEMPERATURECORRECTION
TemperatureZone(note1)
401
LowTemperatureVentilationReduction(note2)
402
LowTemperatureAdjustmentFactor(note3)
403
xtimes
cfm
404
cfm
405
cfm
406
cfm
cfm
AdjustedDesignGrossSupplyAirflow
cfm
406A
AdjustedDesignGrossSupplyAirflow(406A)
divideby
TotalVentilationCapacity(404)
=equals
cfm
cfm
AirflowAdjustmentFactor
TotalVentilationCapacity(TVCfromW2)
=equals
LowTemperatureCorrectedVentilationRate
Notes:
1.frommapinthe"TablesandCharts"sectionoftheHRAIventilationmanual
2.lowestofsupplyorexhaustfromHRV/ERVmanufacturerspecsheet
3.fromtableinthe"TablesandCharts"sectionoftheHRAIventilationmanual
3.AIRFLOWADJUSTMENTFACTOR
DesignGrossSupplyAirflow(note1)
minus
NetSupplyAirflow
+plus
LowTemperatureCorrectedVentilationRate(405)
=equals
407
Notes:
1)theGROSSSUPPLYAIRFLOWfromHRV/ERVmanufacturerspecsheetwhich
correspondstothelowestNETSUPPLYAIRFLOWthatmeetsorexceeds
thecorrespondingcorrectedventilationratefromline405
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW4Ar08/10
MIXEDAIRTEMPERATUREFORCEDWARMAIRSYSTEMS
W4B
line#
1.HRVAIRDELIVERYTEMPERATURE
JobLocation:
DT=
HRV/ERVApparentSensibleEffectiveness
408
OutdoorDesignTemperature(ODT)
409
410
cfm
411
cfm
412
413
ODT+[(21ODT)x%HRV/ERVeff.]
100
AirDeliveryTemperature(DT)
Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesand
IfHRV/ERVnotusedDT=ODT
ChartssectionoftheHRAIventilationmanual.
2.PERCENTAGEHOUSEAIR
OutdoorAirflow(OAF)(Supply)
%HA= RAFOAF
RAF
ReturnAirflow(RAF)
x100
PercentageHouseAir(%HA)
Note:useformulaaboveorpercentage
houseairchartfoundintheTablesandChartssectionoftheHRAIventilationmanual
3.MIXEDAIRTEMPERATURE
MAT=
AirDeliveryTemperature(DT)(410)
PercentageHouseAir(%HA)(413)
MixedAirTemperature(MAT)
MinimumMixedAirTemperature
15.5
RAT[(RATDT)x(100%HA)]
100
414
Note:useformulaaboveormixedairtemperaturechart
foundintheTablesandChartssectionoftheHRAIventilationmanual
4.PREHEATING
TR=15.5MAT
minus
C
MixedAirTemperature(MAT)(414)
=equals
TemperatureRise(TR)
C
415
Note:IfTR(418)isanegativenumbernoheaterisrequired.
ReturnAirflow(RAF)(412)
cfm
xtimes
TemperatureRise(TR)(415)
Preheater=TRxRAFx0.57
xtimes
constant
0.57
=equals
Note:Preheateronlyrequiredifmixedairtemperatureisbelow15.5C
PreheaterSize
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
watts
416
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW4Br08/10
DELIVEREDAIRTEMPERATUREDIRECTDUCTEDSYSTEMSORMAKEUPAIRSYSTEMS
W4C
line#
1.HRVAIRDELIVERYTEMPERATURE
JobLocation
HRV/ERVApparentSensibleEffectiveness
408
OutdoorDesignTemperature(ODT)
409
AirDeliveryTemperature(DT)
410
417
418
cfm
419
watts
420
DT=
ODT+[(21ODT)x%HRV/ERVeff.]
100
Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesand
IfHRV/ERVnotusedDT=ODT
ChartssectionoftheHRAIventilationmanual.
2.HEATING
DesiredDeliveredAirTemperature(DDT)
Delivered AirTemperature
minimums:
minus
AirDeliveryTemperature(DT)(410)
highwalldiffusers=12C
floordiffusers=15.5C
=equals
TemperatureRise(TR)
Note:IfTR(418)isanegativenumbernoheaterisrequired.
TemperatureRise(TR)(418)
xtimes
TR=DDTDT
SystemAirflow(SAF)
xtimes
constant
0.57
=equals
Heater=TRXSAFx0.57
HeaterType
HeaterSize
HRVPostheater
Directoutsideairheater
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW4Cr08/10
SYSTEMLAYOUTGRILLESIZEDOORUNDERCUTS
SYSTEM:
Column
Balancedventilation
ROOMNAME
REQUIREDAIRFLOW
ANDTYPE
(typeaorb)
(CSAF326table1)
Supply
Exhaust
(cfm)
(cfm)
2
3
DESIGNAIRFLOW
(aspersystemlayout)
W5
CentralExhaust
Smallcapacityrecirculation
AIRFLOW
ADJUSTEDAIRFLOW
ADJUST.
(designairflowXcol.6)
Exhaust
Supply
(cfm)
(cfm)
8
7
Supply
(cfm)
4
Exhaust
(cfm)
5
FACTOR
(line407)
6
GRILLE/DIFFUSER
DOOR
UNDERCUT
TYPE
SIZE
10
(inches)
11
TOTALCFM
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW5r08/10
DUCTSIZINGSINGLEDUCT
W6A
2.SYSTEMTOTALEFFECTIVELENGTH
1.EQUIPMENT
Fan#.
Make:
Model:
Designairflow:
EquipmentE.S.P.:
"dia.@
cfm
"w.c.
ft
3.DUCTSIZE
ft
ActualLengthDuctRun:
Equivalentlengthoutsidehood:
w.c.
ft
ft
ft
ft
ft
ft
ft
ft
ft
TotalEffectiveLength:
Sketch
1.EQUIPMENT
2.SYSTEMTOTALEFFECTIVELENGTH
Fan#.
ActualLengthDuctRun:
Equivalentlengthoutsidehood:
Make:
Model:
Designairflow:
EquipmentE.S.P.:
"dia.@
cfm
"w.c.
ft
3.DUCTSIZE
ft
w.c.
TotalEffectiveLength:
ft
ft
ft
ft
ft
ft
ft
ft
ft
Sketch
Prepared By:
HRAI#:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW6Ar08/10
DUCTSIZINGBRANCHEDSYSTEM
1.EQUIPMENT
Model:
System:
W6B
2.DESIGNCONDITIONS
3.OUTSIDEDUCTRUNSIZING
Airflow:
cfm
DesignAirflow:
EquipmentE.S.P.:
cfm
in.w.c.@
cfm
Diameter
in
Pressureloss,outsideduct:
"w.c.
ft
Availablestaticpressure:
"w.c.
Outsideducteffectivelength
Note:Theavailablestaticpressureistobeusedtoselectallductsizesinthefollowingsections4&5
4.BRANCHDUCTSIZING
RunID
Location
Airflow:
ActualLength
Elbowsx__
Eff.Length
Diameter
Rect.Size
RunID
Location
Airflow:
ActualLength
Elbowsx__
ActualLength
ActualLength
Elbowsx__
Elbowsx__
Elbowsx__
ft Eff.Length
in Diameter
x
Rect.Size
RunID
Location
cfm Airflow:
ActualLength
ActualLength
Elbowsx__
Elbowsx__
ft Eff.Length
in Diameter
x
Rect.Size
cfm
ft Eff.Length
in Diameter
x
Rect.Size
EFFECTIVELENGTH
cfm
cfm
cfm
cfm
cfm
cfm
ft
in
Rect.Size
RunID
Location
cfm Airflow:
Elbowsx__
AIRFLOW
TRUNKI.D.
ft Eff.Length
in Diameter
ActualLength
ft Eff.Length
in Diameter
x
5.TRUNKDUCTDESIGN
cfm
ActualLength
Rect.Size
RunID
Location
cfm Airflow:
RunID
Location
cfm Airflow:
RunID
Location
cfm Airflow:
ft Eff.Length
in Diameter
Eff.Length
Diameter
Rect.Size
RunID
Location
cfm Airflow:
DIAMETER
RECTANGULARSIZE
in
ft
in
ft
in
ft
in
ft
in
ft
in
HRAI #:
Job Name:
Signature:
Date:
Job #:
Rect.Size
ft
Prepared By:
ft
in
x
x
x
x
x
x
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW6Br08/10
DUCTSIZINGPOWEREDINTAKE/MAKEUPAIR
1.EQUIPMENT
Fan:
Heater:
W6C
3.TOTALEFFECTIVELENGTH
Make:
ActualLengthDuctRun:
ft
Model:
Equivalentlengthoutsidehood:
ft
ft
Make:
ft
Model:
ft
ft
ft
ft
ft
ft
Designairflow
cfm
2.OPERATINGPOINT
EquipmentESP:
"w.c.
minus
Heaterstaticpressuredrop:
equals=
"w.c.
Availablestaticpressure:
"w.c. 4.DUCTSIZE
TotalEffectiveLength:
ft
ft
"w.c.
"dia@:
Sketch
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW6Cr
08/10
DUCTSIZINGFURNACEOUTSIDEAIRINTAKE
1.REQUIREDAIRFLOW
Systemoperatingspeed
Airflow:
W6D
3.TOTALEFFECTIVELENGTH
ActualLengthDuctRun:
Equivalentlengthoutsidehood:
high
low
cfm
ft
ft
ft
ft
ft
ft
ft
2.SUCTIONPRESSURE
Note:Useactualstaticpressureat
connectionpointifpossible
Ifpressure isunknownuse.1"w.c.for
highspeedand.05in.w.c.forlowspeed
highspeed
"w.c.
lowspeed
"w.c.
ft
ft
ft
TotalEffectiveLength:
ft
ft
4.INTAKEDUCTSIZE
speed
high
low
"dia@:
"w.c.
Sketch
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW6Dr08/10
DUCTSIZINGPASSIVEMAKEUP/RELIEFAIRDUCTSIZING
1.PRESSURE
W6E
3.TOTALEFFECTIVELENGTH
ft
ActualLengthDuctRun:
ft
Equivalentlengthoutsidehood:
Depressurization/pressurization
Limit:
Pa.
2.AIRFLOW
test
depressurizationatCEC
(pg220Manual)excessiveflowfactor
Pa.
timesx
netexhaustatCEC
equals=
Designairflow
cfm
cfm
ft
ft
ft
ft
ft
ft
ft
ft
ft
ft
TotalEffectiveLength:
OR
calculation
4.DUCTSIZE
form: W3A
W3B
W3C
Designairflow:
cfm
"dia@:
w.c
Sketch
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW6Er08/10
W7
CONTROLSTRATEGY
CONTROLDEVICE
1.
2.
3.
4.
5.
6.
7.
Prepared By:
HRAI #:
Job Name:
Signature:
Date:
Job #:
Official Use:
CopyrightHRAIResidentialVentilationWORKSHEETW7r08/10
DEPRESSURIZATIONTESTREPORT
Note:Thistestisforcodecomplianceoftheventilationsystemonly.
Thisisnotacombustionsystemtestorabackspillagetest.
BUILDER/HOUSE
EXHAUSTAPPLIANCES
DescribeAllExhaustAppliances
1)
capacity
2)
capacity
3)
capacity
cfm(L/s)
OnatTVCC?
OnatCEC?
City:
P.C.
Phone:
cfm(L/s)
OnatTVCC?
OnatCEC?
Fax:
EmailAddress:
MEASUREMENTS
cfm(L/s)
OnatTVCC?
Dateoftest:
OnatCEC?
4)
capacity
cfm(L/s)
OnatTVCC?
OnatCEC?
5)
capacity
cfm(L/s)
OnatTVCC?
OnatCEC?
6)
capacity
HouseID#:
Name:
Address:
mm/dd/yy
Note: Testtobecarriedoutwhenhouseissubstantiallycomplete
Wind:
km/h(mph)
Note: Windconditionsshouldbelessthan15km/h(9mph)
SEEOVERFORPROCEDUREDESCRIPTION
cfm(L/s)
OnatTVCC?
OnatCEC?
COMBUSTIONAPPLIANCES
1.
Starting"Rest"Pressure
Pa (a)
Pressure@TVCC
Pressure@CEC
Pa (b)
Ending"Rest"Pressure
Pa (d)
Pa (c)
Pa
DepressurizationLimit
2.
DepressurizationLimit
Pa
DepressurizationLimit
Pa
DepressurizationLimit
Pa
DepressurizationLimit
Pa
3.
4.
DEPRESSURIZATION@TVCC
(b) minus (a) =
Pa (e)
(b) minus (d) =
Pa (f)
Pa
Largestof(e)or(f)=Dep.@TVCC
Note:Depressurizationlimitfromleft,butnomorethan10Pa.
5.
DEPRESSURIZATION@CEC
(c) minus (a) =
Pa (g)
(c) minus (d) =
Pa (h)
Pa
Largestof(g)or(h)=Dep.@CEC
Pa
LowestDepressurizationLimit
TESTINSTRUMENT
Note:IfanyexhaustequipmentrequiredtorunattheCECisnotinstalled
itmustbesimulatedandtheflowverifiedbyflowmeasurementstation
orequivelant
Make:
Type:
TESTTESULTS
Note:Thetestmustbeperformedusinganinstrumentcapableof
Thedwellingunitandsystemsatthetimeoftest:
measuring0to60Pa.rangewithasensitivityof2Pa.
0.02
0.04
0.20
10
50
TESTFIRMINFORMATION
JobName:
JobNumber:
Name:
doesnotconform
tothedepressurizationrequirementsofCSAF326M91.
CERTIFICATION
ICERTIFYTHATTHETESTHASBEENPERFORMEDINACCORDANCEWITHTHETEST
PROCEDURESETOUTINCSAF326M91PARAGRAPH11.2.2.a(i)AND11.2.2b(i)
Date:
Address:
Tel:
conforms
mm/dd/yy
Tel:
PostalCode:
Fax:
Name:
HRAICertification#:
Signature:
CopyrightHRAIResidentialVentilationr08/10