Vous êtes sur la page 1sur 6

DSC/DPC Alarm Handling Use Cases

Use Case 1:
Scenario First time Initialization when the EMS, OAM Agent and DSC/DPC
application comes up
- Initial Sync ->EMS discovers OAM agent through sysOID discovery procedure. EMS
issues a getbulk to sync up the data with OAM agent. All Links status and DSC/DPC
op state is down.
- OAM Agent is up with user defined XML values.
- In this scenario all the links are coming up after the DPC/DSC status made up as
part of INIT-Complete.
EMS
DPC/DSC

OAM Agent
Initial_Sync
Init_Start
CFG_Params

No
Alarms/Notifications

INIT-complete
DPC/DSC Op stats up (Notification)
Interface statusup(link comes up)
.
.
Interface status-up (link comes up)
.
No alarm raised
previously
and

Link Status up (Notification)

Bid/DSC Added(Notification)
only params)

Bid Info /DSC Info(Read

Use Case 2:
Scenario First time initialization when the EMS, OAM Agent and DSC/DPC
application comes up. Here we receive the link status up indications
before the OP status for DSC/DPC is UP.
-

The link status indication from application is received before the OP status UP
indication from application.

EMS
DPC/DSC

OAM Agent
Initial_Sync
Init_Start
CFG_Params

Link Status UP/DOWN


DPC/DSC Op Status Down.
Link status indication
(up/down) is stored at OAM
agent

complete

INITINIT-complete

DPC/DSC Op stats up(Notification)


INIT_COMPLETE

Link Status
Info

No alarm raised
previously
and
DPC/DSC OP status up

(Notification)

Bid Info/DSC Info (Read only


params)

Bid

Use Case 3:
Scenario EMS, OAM Agent and DSC/DPC application are all up. DSC/DPC
binary goes down.
-There is a periodic heart beat message which is sent from OAM agent to DSC/DPC.
Once the heartbeat message fails, OAM agent raises all link alarms and DPC/DSC
node failure alarm towards EMS.
-Link status Up indication from application is received before the DPC/DSC op status
Up.
EMS
DPC/DSC

OAM Agent
Heartbeat fails
DPC/DSC op status down (Alarm Critical)

Alarm-Link status down (Alarm critical) raised


Clear the Bid/Dsc/Enode B etc read
only parameters value

Clear the Bid/DSc/Enode B etc read only


parameters value and update the alarm
entry table

Init_Start
CFG_Params

Link Status Up
Link Status UP indication
DPC/DSC Op Status Down.
Alarm for links already raised, mark
the alarm cleared but do not delete
the alarm instance

DPC/DSC Op stats up (alarm =cleared)


INIT_COMPLETE
Link Status Up (Alarm = cleared,Delete the alarm entry)
DSC/Bid add
Start adding read only param
values from fresh.

INIT-complete

Bid Info /DSC Info Added Notification

Use Case 4:
Scenario EMS, OAM Agent and DSC/DPC application are all up. DSC/DPC
goes down before Init_Start message.
-There is a periodic heart beat message which is sent from OAM agent to
DSC/DPC .Once the heartbeat message fails, OAM agent raises all link alarms and
DPC /DSC node failure alarm towards EMS.
-Link status Up indication from application is received after the DPC/DSC Op Status
Up happens.

EMS
DPC/DSC

OAM Agent
Heartbeat fails
DPC/DSC op status down (Alarm Critical)

Alarm-Link status down (Alarm critical) raised


Clear the Bid/Dsc/Enode B etc read
only parameters value

Clear the Bid/Dsc/Enode B etc read


only parameters value

Init_Start
CFG_Params

DPC/DSC Op stats up (alarm =cleared)


INIT_COMPLETE
Link Status Up indication
Link Status UP indication
DPC/DSC Op Status UP
Alarm for links already raised, send
clear alarm to EMS no need to store
the alarm

INIT-complete

Link Status Up (Alarm = cleared)


DSC/Bid Info add (Read only)
Start adding read only parameter
values from fresh.

Use Case 5:
Scenario INIT_FAIL before INIT_COMPLETE message received from the
DPC/DSC
-There is a periodic heart beat message which is sent from OAM agent to
DSC/DPC .Once the heartbeat message fails, OAM agent raises all link alarms and
DPC /DSC node failure alarm towards EMS
-After DSC/DPC comes starts connecting, Init failure happens at application

EMS
DPC/DSC

OAM Agent
Heartbeat fail

DPC /DSC op state down, Link state Down (Alarm =critical)

INIT-START
CFG PARAMS
INIT CONFIG FAILURE ALARM =Critical

INIT CONFIG FAILURE ALARM =Cleared

INIT-FAIL

INIT-START
CFG PARAMS

DPC Op stats up (alarm =cleared)

INIT-COMPLETE

Vous aimerez peut-être aussi