Technical Data
Ordering Information
Medium:
Neutral gaseous liquids or aggressive fluids
Operation:
Solenoid operated
Flow Direction:
Optional
Port Size:
G1/4, 1/4 NPT
Operating Pressure:
0 to 10 bar
Operating Temperature:
-25C to +80C (NBR)
-10C to +120C (FKM) water up to +95C
Fluid Temperature:
+60C
Switching Cycles:
100/min
Mounting:
Optional, preferably vertical
Materials:
Body stainless steel, brass, hard anodized aluminium
Seat seal FKM (Viton), NBR (Perbunan), Silicon
Inner parts stainless steel, brass
Options
Namur Interface
Add-on manual override for commissioning
and maintenance
Many mounting possibilities
Valve/solenoid combinations to protection class
IP65 and explosion proof with DVGW
approval on request
TV approval
Solenoids in protection class EEx d IIC T5/T6
Solenoids with CSA-/FM approval
Connectors
See data sheet 7503364
2
Switching function:
Pressure port
at 1, 2 or 3
1 3
NAMUR interface
7503322.06.08.99
24011
General Information
Brass valves
Type *
Port size
Operating pressure 1)
(bar)
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
2401103
G 1/4
0 to 10
0,340
NBR
M01
0,65
2401149
G 1/4
0 to 10
0,340
NBR
M01
0,65
2401138
1/4 NPT
0 to 10
0,340
NBR
M01
0,65
2401126
G 1/4
0 to 10
0,340
FKM
M01
0,65
2401107
G 1/4
0 to 10
0,340
NBR
M01
0,70
Manual override
without detent
2401148
1/4 NPT
0 to 10
0,340
NBR
M01
0,70
Manual override
without detent
2401119
G 1/4
0 to 10
0,340
NBR
M01
0,70
Manual override
with detent
2401140
1/4 NPT
0 to 10
0,340
NBR
M01
0,70
Semi-automatic
actuation
2401153
G 1/4
0 to 10
0,340
Silicon
M01
0,65
2401106
1/4 NPT
0 to 10
0,340
Silicon
M01
0,65
2401154
G 1/4
0 to 10
0,340
Silicon
M01
0,70
Semi-automatic
actuation, for amb.
temp. down to -40 C
Variants
DVGW approval
solenoids Group A
Port size
Operating pressure1)
(bar)
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
Variants
2401190
G 1/4 NAMUR
0 to 10
0,340
NBR
M02
0,55
DVGW approval
solenoids Group A
2401116
G 1/4 NAMUR
0 to 10
0,340
NBR
M02
0,55
2401133
G 1/4 NAMUR
0 to 10
0,340
Silikon
M02
0,55
2401191
G 1/4 NAMUR
0 to 10
0,340
NBR
M02
0,55
DVGW approval
solenoids Group B
1025254
0 to 10
0,340
NBR
M02
0,55
2401109
G 1/4 NAMUR
0 to 10
0,340
NBR
M03
0,55
7503322.06-2
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
8/99
24011
Port size
Operating pressure1)
(bar)
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
Variants
2401186
G 1/4
0 to 10
0,340
NBR
M01
0,65
2401112
1/4 NPT
0 to 10
0,340
NBR
M01
0,65
Variants
Port size
Operating pressure1)
(bar)
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
2401127
G 1/4
0 to 10
0,340
FKM
M01
0,65
2401147
1/4 NPT
0 to 10
0,340
FKM
M01
0,65
2401155
G 1/4
0 to 10
0,340
Silicon
M01
0,65
2401168
1/4 NPT
0 to 10
0,340
Silicon
M01
0,65
2401145
G 1/4
0 to 10
0,340
FKM
M01
0,70
Semi-automatic
actuation
Port size
Operating pressure1)
(bar)
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
Variants
2401196
G 1/4 NAMUR
0 to 10
0,340
NBR
M02
1,0
2401142
G 1/4 NAMUR
0 to 10
0,340
Silicon
M02
1,0
8/99
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
7503322.06-3
24011
Solenoids Group A
Type
Power consumption
24V DC 230V AC
(W)
(VA)
Current
24V DC
(mA)
Tolerance (%)
pull-in current
at 100% duty cycle
+
- 2)
Protection class
230V AC
(mA)
0800
0801
16,9
703
10
25
3803
3804
18
185
10
25
3980 1)
12
502
10
3981 1)
14
3970 1)
7,6
3971 1)
9,0
61
315
39
Temperatures
Ambience Fluid
(C)
(C)
Dimensional Circuit
drawing
diagram No.
Weight
(kg)
+80
M06
SB01
0,33
+80
M07
SB06
0,34
EEx me II T5
EEx me II T6
+60
+45
+60
+45
M08
SB04
0,85
25
+60
+45
+60
+45
SB07
0,85
25
EEx me II T5
EEx me II T6
M08
10
+70
+50
+70
+50
SB04
0,85
20
EEx me II T4
EEx me II T6
M08
10
+70
+50
+70
+50
SB07
0,85
20
EEx me II T4
EEx me II T6
M08
10
+70
+50
+70
+50
SB04
0,85
20
EEx me II T4
EEx me II T6
M08
10
315
3826
13,6
566
10
25
NEMA
4, 4X, 6, 6P, 7, 9
+60
M09
SB01
0,4
3827
15,7
68
10
25
NEMA
4, 4X, 6, 6P, 7, 9
+60
M09
SB05
0,4
Power consumption
24V DC 230V AC
(W)
(VA)
Current
24V DC
(mA)
Tolerance (%)
pull-in current
at 100% duty cycle
+
-
Protection class
230V AC
(mA)
Temperatures
Ambience Fluid
(C)
(C)
Dimensional Circuit
drawing
diagram No.
Weight
(kg)
0827 3)
0813 3)
6,8
282
10
+60
M07
SB01
0,33
3960 1)
3,9
161
10
10
EEx me II T5
EEx me II T6
+80
+60
+80
+60
M08
SB04
0,85
3961 1)
4,9
21
10
10
EEx me II T5
EEx me II T6
+80
+60
+80
+60
M08
SB07
0,85
161
10
10
EEx me II T5
EEx me II T6
+80
+60
+80
+60
M08
SB04
0,85
3824
8,9
370
10
10
NEMA
4, 4X, 6, 6P, 7, 9
+60
M09
SB01
0,4
3825
9,5
41
10
10
NEMA
4, 4X, 6, 6P, 7, 9
+60
M09
SB05
0,4
Solenoids Group B
Type
1)
2)
3)
4)
5)
7503322.06-4
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
8/99
24011
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
drawing
2401189.361X G 1/4
0 to 10
0,340
NBR
M04
0,65
0 to 10
0,340
NBR
M04
0,65
2401118.361X G 1/4
0 to 10
0,340
Silicon
M04
0,65
0 to 10
0,340
Silicon
M04
0,65
Variants
Type *
Port size
Variants
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
2401193.361X G 1/4
0 to 10
0,340
FKM
M04
0,75
0 to 10
0,340
FKM
M04
0,75
2401130.361X G 1/4
0 to 10
0,340
FKM
M04
0,80
Manual override
with detent
0 to 10
0,340
FKM
M04
0,80
Manual override
without detent
0 to 10
0,340
FKM
M04
0,80
Semi-automatic
actuation
Variants
Type *
Port size
kv-value
(Cv(US) kv x 1,2)
Seat seal
Dimensional
0 to 10
0,340
NBR
M05
0,65
0 to 10
0,340
NBR
M05
0,65
Type *
Port size
DVGW approval
* When ordering, please indicate solenoid, voltage and current type (frequency).
1)
8/99
Power consumption
24V DC 230V AC
(W)
(VA)
Current
24V DC
(mA)
Tolerance (%)
pull-in current
at 100% duty cycle
+
- 2)
Protection class
230V AC
(mA)
Temperatures
Ambience Fluid
(C)
(C)
Dimensional Circuit
drawing
diagram No.
Weight
(kg)
3616
14,3
598
10
20
EEx d IIC T5
EEx d IIC T6
+60
+40
+60
+40
SB02
0,8
3617
16,1
70
10
20
EEx d IIC T5
EEx d IIC T6
+60
+40
+60
+40
SB06
0,8
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
7503322.06-5
24011
98
12
35,7
2
3
12,2
Pg 13,5
12
51
5,5
30
For port sizes see
General information
27
55
M02
G1/4
37,5
19,5
19,5
19
6,5
22,5
6,5
22
15,5
4,5
13
7,5
1
G1/4
Pg 13,5
52
2
5,5 x 3 deep
26,5
24
12
15,5
13,5
109
15
19
G1/4
M5
80
50
16
32
17
50
M03
13,5
4
22
52
5,5 x 3 deep
1,5
7,5
4,5
13
M6
Pg 13,5
10
26,5
24
6,5
16
32
17
Add-on manual override
7503322.06-6
22,5
6,5
G1/4
12
3
37,5
109
15
19
G1/4
M5
80
50
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
50
8/99
24011
M04
108
28
60
133
1/2-14 NPT
27
12
5,5
approx. 13
30
20,5
12
37
55
Manual override
without detent
M05
24,2
35,7
2
3
12,2
51
Manual override
with detent
108
60
28
4,5
7,5
22
G1/4
37,5
G1/4
15,5
1
19
52
2
5,5 x 3 deep
13
26,5
24
12
19,5
13,5
15
19
G1/4
M5
143
1/2-14 NPT
6,5
22,5
6,5
16
32
17
50
50
Add-on manual override
8/99
Threaded plug
with detent
Type: 0601765
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
Type: 0602764
7503322.06-7
24011
M07
63,5
49
60
43
27
12
27,5
Pg 11
27,5
34
21
Connector can be
indexed 4 x 90
12
Pg 11
34
Connector can be
indexed 4 x 90
43
40,5
56
40,5
17
59
27
89
99
M09
1/2 - 14 NPT
80
60
41
40,5
M08
16
Pg 13,5
63
16
33
119
84
43
33,5
62
66
63
Circuit diagrams
SB01
SB02
SB04
SB05
SB06
SB07
7503322.06-8
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
8/99
24011
NAMUR interface
24
M5 x 8 deep
32
12
Coding stud
M5x10 DIN 913-45 H
M5
G1/4 (DIN/ISO 228/1)
Mounting parts
Designation
Type
Application
Flange plate
Yoke
Adapter plate
0559857
0540593
0603216
Direct attachment to pneumatic linear actuators with NAMUR ribbing and for wall mounting, depending on the tubing position
In conjunction with a flange plate for attachment to pneumatic linear actuators with NAMUR pillar (round)
Direct attachment to older design pneumatic pivot drives, with interface for valve Type 2401180
Weight
(kg)
0,50
0,10
0,25
See
data sheet
7502242
Warning
These products are intended for use in industrial systems only. Do not
use these products where pressures and temperatures can exceed
those listed under Technical Data.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications
not within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is
warned to consider the failure modes of all component parts used in
8/99
Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
7503322.06-9