Vous êtes sur la page 1sur 3

8/25/2015

MPSPACompactWorkstationMeasurement,openandclosedloopcontrolinminimalspaceCompactWorkstationProcessAutomationLearni

MPSPACompactWorkstationMeasurement,open
andclosedloopcontrolinminimalspace

Optimumuseofspace
Doyouhavelimitedspaceordoyouwanthighcomplexityfromanindividualtrainingstation?
Ifso,theMPSPACompactWorkstationwith4integratedcontrolloopsistheperfectsolution.

Corecompetence:TheRIflowchart
Astheflowchartshows,theindividualcontrolloopscanbeactivatedsimplybyadjustingtheballvalves.The
flexiblepipingsystemallowsquickchangestotheflowpatternorintegrationofadditionalcomponents.

Hugeflexibility
Controllersandoperatingunitsarenotpermanentlyinstalled,butaresimplyclickedintoplaceintheER
http://www.festodidactic.com/inten/learningsystems/processautomation/compactworkstation/mpspacompactworkstationmeasurement,openandclosed

1/3

8/25/2015

MPSPACompactWorkstationMeasurement,openandclosedloopcontrolinminimalspaceCompactWorkstationProcessAutomationLearni

mountingframe.Thisenablesthecontroller,operatingunitortouchpaneltobereplacedinnexttonotime.

Option:refrigerationengineering
ThestandardversionoftheMPSPACompactWorkstationprovides4controlloops.Inaddition,acoolingunit
withheatexchangerandawater/aircoolerareavailable.Thisresultsinevenmoreoptionsfortemperature
control.

Networkedtechnologies
Anincreasingnumberofvalveswithpneumaticdrivesarebeingusedinwatersupplyanddisposal.Thisissafer
andmoreenergyefficient.Therefore,nomodernlearningsystemshouldbewithouta2wayballvalvewith
pneumaticprocessdriveandsignalbox.Itrepresentstheincreasingintegrationofdifferenttechnologiesin
processautomation.

Professionalperformancerecording
TheSentronPAC4200multifunctionmeasuringunitfromSiemensrecordsandsavesmeasuredvaluessuchas
voltage,currentandenergyconsumption,allowinganalysisofthenetworkquality.Theunitcanbeincorporated
intomastercontrolsystemsandenergymanagementsystemsviaEthernet.

http://www.festodidactic.com/inten/learningsystems/processautomation/compactworkstation/mpspacompactworkstationmeasurement,openandclosed

2/3

8/25/2015

MPSPACompactWorkstationMeasurement,openandclosedloopcontrolinminimalspaceCompactWorkstationProcessAutomationLearni

Onthetrailofwaste
Identifyingpotentialsavingsmeansfirstofall:measuringcurrentconsumption.TheWattmeteractsasasmart
meterfortrainingsystemswitha24VDCpowersupplyandamaximumof120Watts.Aswitchableinterfacefor
010VDCor420mAisintegratedfordatatransmission.Ethernetisavailableasanoption.

Hottopic:energyefficiency
Aseverywhereinautomation,softwareplaysanoutstandingroleintheCompactWorkstation,e.g.inmeasuring
technology.Theprocessdatacanbeclearlyvisualisedusingthemeasuringsoftwareandthenanalysedby
eitherthewholeclassorasgroupwork.

Theexcitingquestionswaitingtobeanswered:
Whatprocessstepsleadtounwantedincreasedenergyconsumption?
Howcanconsumptionpeaksbeavoided?
Whatdoesitachieve,whatdoesitcost?
Whichinvestmentsorchangeswillachievethegreatesteffects?
TrainingwiththeMPSPACompactWorkstationbecomesamultifaceted,excitingandcrosssubjectproject.

http://www.festodidactic.com/inten/learningsystems/processautomation/compactworkstation/mpspacompactworkstationmeasurement,openandclosed

3/3

Vous aimerez peut-être aussi