Vous êtes sur la page 1sur 49

Internal

BAM Introduction
ISSUE 2.1

HUAWEI TECHNOLOGIES CO., LTD.

www.huawei.com

All rights reserved

Upon completion of this course, you


will be able to:
Grasp the structure of BAM
software
Perform the process of BAM
installation and Backup
Grasp data configuration
operations in BAM

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

References

MSOFTX3000 Architecture and Principle

- Maintenance Management Subsystem

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 1 BAM Software Structure


Chapter 2 BAM Software Management
Chapter 3 BAM Data Configuration Related Topic

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

BAM server/client work mode

BAM

HOST

WS

WS

LAN1

HUAWEI TECHNOLOGIES CO., LTD.

LAN2

All rights reserved

Page 5

BAM Server/Client Work Mode


0# Subrack

FE 1

RS232

Fan Monitor

FE 2

NC1

NC0

NC1

NC0

RS422

1# Subrack

0#IGWB

0# LanSwitch
RS232

GE

Fan Monitor

1#IGWB
2# Subrack
NC2

1# LanSwitch
BAM

RS232

Fan Monitor

NC1

NC0

Optional
Remote Maintenance Device Interface
ROUTER

HUB

9# Subrack
MODEM

Remote Maintenance Device

RS232

Fan Monitor

HUAWEI TECHNOLOGIES CO., LTD.

WS0

All rights reserved

WSn

WS1

Page 6

BAM Reliability and Flexibility Design

Reliability

BAMs hard disk configuration adopts RAID 1 with a full


mirror of data in BAM.
BAM Emergency Work Station will take place of BAM when
BAM has problem. It backups data every 4 hours.
Flexibility

BAM can be installed in IBM or HP server.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 7

BAM Software Structure


BAM Application

Monitor Service: BAM Service


Process Management : BAM Manager
Other Processes
BAM server
application
layer
Operation
System Layer

SQL Server 2000

Windows 2000 Server

HP/IBM Server hardware platform

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

BAM Processes Introduction

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

BAM Manager

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

BAM Service Process

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Smirror Process

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Questions

Whats the function of BAM process?

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Chapter 1 BAM Software Structure


Chapter 2 BAM Software Management
Chapter 3 BAM Data Configuration Related Topic

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Chapter 2 BAM Software Management


Section 1 BAM Software Installation
Section 2 BAM database Backup & Restore
Section 3 BAM Server Gateway Tool

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

BAM Software Installation before Delivery


Start

Setting hard disk in RAID 1 mode

Installing SQL Server 2000

Installing SQL Server 2000


Service Pack 3

Installing Windows 2000 Server

Setting hard disk partitions

Installing BAM server software

Installing driver for network adapter

Setting IP address of network adapter

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Setting automatic login to


Windows 2000 Server

End

Page 16

On-site Installation of BAM Software


Start
Check whether the operating
system and database run
normally
Yes
Modify the computer name

No

Perform factory
installation

Modify the administrator


password of Windows 2000
Server

Modify factory-default settings


Modify the administrator
password of SQL Server
2000
Modify IP addresses of
network adapters
Install the BAM server
software

Set automatic login to


Windows 2000 server

End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 17

On-site Installation of BAM Software


Check BAM Hard Disk in RAID 1 Mode
Check Hard Disk Partitions

Set IP Address of Network Adapter

Modify Computer Name and Workgroup


Modify System Administrator Password of Windows 2000 Server
Modify System Administrator Password of SQL Server 2000
Set language

Set Automatic Login to Windows 2000 Server

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Setting BAM Hard Disk in RAID 1 Mode


Integrated Lights-Out press [F8] to

configure
Press <F8> to run the Option ROM Configuration for Arrays Utility
Press <ESC> to skip configuration and continue

The following information means setting correct


Logical Drive # 1, RAID 1, 33.9 GB, OK

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Check Partitions and Capability of Hard Disk


Partition capacity of logical drive is assigned with the following :

Drive C: 6 GB, install operating system (Windows 2000


Server) and database management software (SQL Server
2000).
Drive D: 15 GB, install BAM server software and storing the
system databases.
Drive E: 3 GB, store the log files of the databases.
Drive F: remain space (about 10.3 GB), mainly used for
backing up system databases, and registry information.

Attention: The File system format should be NTFS.


HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

BAM Software Installation Directory


File path

Description

D:\Data

Storing all files to be loaded to the host

D:\Mssql

Storing system database files, including sub-folders

D:\Mssql\Data

Storing system database files

E:\Mssql

Storing database log files, including sub-folders

E:\Mssql\Data

Storing database log files

F:\MSOFTX3000

It is the default system backup folder which stores BAM registry and
database files.

E:\Mssql\Data\Alarm_Log.LDF

Log file corresponding to Alarm database

E:\Mssql\Data\Bam_Log.LDF

Log file corresponding to Bam database

E:\Mssql\Data\BillData_Log.LDF

Log file corresponding to BillData database

E:\Mssql\Data\Stats_Log.LDF

Log file corresponding to Stats database

F:\MSOFTX3000\BamYYYYMM
DD.dat

BAM database backup file generated on MM (month) DD (day)


YYYY (year)

F:\MSOFTX3000\InitialDbBkp.dat

It is the initial BAM database file. By replacing the present file with
this file, BAM database state is restored to initial state.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Set Network Adaptor of BAM


172.20.200.0 / 255.255.0.0

Customized IP address

To LAN Switch 0

To external network

Network adapter 3

Network adapter 1

Network adapter 4

Network adapter 2

IBM server chassis back

172.30.200.0 / 255.255.0.0
To LAN Switch 1

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Set Network Adaptor of Emergency Work Station


PC chassis rear

Network adapter 1
Customized IP address

To external network

Network adapter 2
Standby
Network adapter 3

Network adapter 4

172.20.200.0 / 255.255.0.0

Connected to LAN Switch 0 in


case of emergency

172.30.200.0 / 255.255.0.0

Connected to LAN Switch 1 in


case of emergency

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

Modify System Administrator Password of Windows 2000 Server

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 24

Modify System Administrator Password of SQL Server 2000

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Modify System Administrator Password of SQL Server 2000

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Set Automatic Login

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

Set Software Backup Directory

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Chapter 2 BAM Software Management


Section 1 BAM Software Installation
Section 2 BAM database Backup & Restore
Section 3 BAM Server Gateway Tool

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

BAM Automatic Backup


System will automatically backup BAM Database and

Register Table in F:\MSOFTX3000\ at 4:30 AM everyday


BAM database :

BamYYYYMMDD.dat saving data of latest seven


days( except Sunday) as well as the data of latest 4
Sunday
BamMonthBak.dat saving the data of the first day of
each month
Register Table

BamReg.bak saving the latest Register Table

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Manual Backup(1)

Use the command BKP DB:


Backup BAM database and register to the directory F
\MSOFTX3000

This is more common than using SQL Server to Backup.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

Manual Backup(2)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Manual Backup(3)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

Manual Backup(4)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

BAM Database Restore(1)

Before restoring BAM, you should stop BAM Service and Smirror Service
in the Services Windows , then stop and close Bam Manager.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

BAM Database Restore(2)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

BAM Database Restore(3)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

Chapter 2 BAM Software Management


Section 1 BAM Software Installation
Section 2 BAM database Backup & Restore
Section 3 BAM Server Gateway Tool

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Set BAM Server Gateway Tool(1)

BAM Server Tool is used to connect alarm box

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

Set BAM Server Gateway Tool(2)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 40

Chapter 1 BAM Software Structure


Chapter 2 BAM Software Management
Chapter 3 BAM Data Configuration Related Topic

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

Data Management Principle


LMT Data Configuration

SQL server DB

FMT

D:\DATA

LON
Program Writeable
Data Writeable

HOST

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 42

Commands Usage

MML Commands Usage


Command

Description

ADD

To add data

MOD

To modify data

RMV

To remove data

LST

To list BAM data

DSP

To display host data, state of equipment, or resource


consumption

SET

To set data or state

LOF

Offline

LON

Online

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 43

Configuration Steps

When deploying a new site, configurations need


Set data offline
Prepare online setting data
Reload data
Command

Set data
offline

Description

LOF

To set data offline

SET CWSON: SWT=OFF

To disable the alarm switch

SET FMT: STS=OFF

To disable the format conversion switch

To configure data

LON
Prepare
SET CWSON: SWT=ON
online
SET FMT: STS=ON
setting data
FMT
Reload data

To set data online


To enable the alarm switch

To enable the format conversion switch


To format data

Power off, power on, and start


loading

HUAWEI TECHNOLOGIES CO., LTD.

To reload data

All rights reserved

Page 44

Mandatory and Optional Parameters


For MML commands, the parameters in red are mandatory while gray

means optional.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 45

Default Value
It means select all the options while giving nothing in the field of choice.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 46

Questions
Which operation is necessary during the loading process

What is difference between LST and DSP?

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 47

Summary

Summary

BAM software structure

BAM Software Management


Data configuration operations

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 48

Thank You
www.huawei.com

Vous aimerez peut-être aussi