Académique Documents
Professionnel Documents
Culture Documents
Index
18 to 1 sizes
316 stainless steel, brass, and exotic
materials
NPT threads
HOKE Incorporated
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com
3
3
3
3
4
4
4
5
5
5
5
6
6
6
6
7
7
7
7
8
8
CNPClose Nipple
NPHex Nipple
RNPHex Reducing Nipple
LNPHex Long Nipple
APAdapter
RAPReducing Adapter
RBPReducing Bushing
CGPHex Coupling
RCGPReducing Coupling
CPPCap
PPPlug
FLPFemale Elbow
SLPStreet Elbow
RSLPReducing Street Elbow
MLPMale Elbow
FTPFemale Tee
STPStreet Tee
FTBMMale Branch Tee
MTPMale Tee
CSPCross
Safety Instructions
Materials
Pressure Ratings
Pressure ratings for temperatures up to 100 F are
identified for each individual pipe fitting in the dimensional data charts.
Temperature*
Temperatures noted below apply to basic fitting capabilities. In all cases consideration must also be given to
the type of thread sealant used. For example, Teflon
tape has a maximum temperature rating of 450 F.
316 stainless steel: 325 F to +1200 F
(198 C to +648 C)
Brass:
325 F to +400 F
(198 C to +204 C)
ASTM A-182
ASTM A-479
QQ-B-626
ASTM B-453
QQ-B-626
Heat Traceability
HOKEs 316 Stainless Steel Precision Instrument Pipe
Fittings are heat code traceable. To obtain certified
material test reports (CMTRS) for these components,
place separate orders for such items and specify
CMTRS required.
* Prolonged exposure to temperature over 800 F is not recommended.
HOKE Incorporated
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com
Threads
MATERIAL
BRASS BR
316 SS 316
EXAMPLE: 4RAP2316
RAP
316
Reducing
Adapter
18 NPT
Assembly Instructions
To ensure a leak-tight seal, the use of a pipe thread sealant is recommended. One commonly utilized technique is Teflon Tape.
The chart below provides information regarding the recommended tape width and the approximate number of threads which
should be wrapped
APPROX. # OF THREADS
18
18
38
713
38
38
916
723
1116
* ISA Handbook of Control Valves. Note: Dimensions are in inches. The Pipe Thread Sealants may have lower temperature capabilities than the basic fitting.
Example: For a NPT, L = 38
Approximate number of threads which should be wrapped = 713
HOKE
DIMENSIONS
MALE
E (MIN. OPENING)
BRASS
316SS
4CNP [ ]
118
932
5700
9900
6CNP [ ]
38
118
38
5500
9000
8CNP [ ]
2764
5400
8900
12CNP [ ]
58
4600
8300
DIMENSIONS
MALE
E MIN
F HEX
BRASS
316SS
1NP [ ]
116
11364
18
516
7100
12,300
2NP [ ]
18
1732
316
716
7100
12,300
4NP [ ]
11932
932
916
5700
9900
6NP [ ]
38
158
38
1116
5500
9000
8NP [ ]
1532
78
5400
8900
12NP [ ]
58
1116
4600
8300
18NP [ ]
78
138
3400
5900
PIPE SIZE
DIMENSIONS
MALE
REDUCED MALE
E MIN
BRASS
316SS
2RNP1 [ ]
18
116
1316
332
716
7100
12,300
4RNP2 [ ]
18
1932
316
916
7100
12,300
6RNP4 [ ]
38
932
1116
5700
9900
8RNP4 [ ]
11116
932
78
5700
9900
8RNP6 [ ]
38
11116
38
78
5500
9000
12RNP6 [ ]
38
12332
38
1116
5500
9000
12RNP8 [ ]
12932
716
1116
6200
10,100
16RNP8 [ ]
2932
716
138
6200
10,100
16RNP12 [ ]
2932
58
138
4600
8300
DIMENSIONS
MALE
E MIN
F HEX
BRASS
316SS
2LNP [ ]/200
18
316
716
7100
12,300
2LNP [ ]/250
18
316
716
7100
12,300
4LNP [ ]/200
932
916
5700
9900
4LNP [ ]/250
932
916
5700
9900
4LNP [ ]/300
932
916
5700
9900
4LNP [ ]/400
932
916
5700
9900
6LNP [ ]/200
38
1116
1116
5500
9000
6LNP [ ]/250
38
1116
1116
5500
9000
6LNP [ ]/400
38
1116
1116
5500
9000
8LNP [ ]/300
78
78
5400
8900
12LNP [ ]/300
1116
1116
4600
8300
16LNP [ ]/300
138
138
3400
5900
16LNP [ ]/400
138
138
3400
5900
HOKE
F-Hex
E
DIMENSIONS
MALE
E MIN
F HEX
BRASS
316SS
2AP [ ]
18
316
916
4200
7300
4AP [ ]
138
932
4200
7300
6AP [ ]
38
1916
38
78
3400
5500
8AP [ ]
12932
1532
1116
2700
4900
12AP [ ]
13132
2132
2100
3700
F-Hex
E
PIPE SIZE
DIMENSIONS
ORDER BY PART
NUMBER
FEMALE
MALE
E MIN
F HEX
BRASS
316SS
4RAP2 [ ]
18
316
4200
7300
6RAP2 [ ]
38
18
1516
316
78
3400
5500
6RAP4 [ ]
38
932
78
3400
5500
8RAP4 [ ]
932
1116
2700
4900
8RAP6 [ ]
38
38
1116
2700
4900
12RAP4 [ ]
11316
932
2100
3700
12RAP6 [ ]
38
11316
38
2100
3700
12RAP8 [ ]
1532
2100
3700
16RAP8 [ ]
1532
158
2500
4300
16RAP12 [ ]
58
158
2500
4300
HOKE
PIPE SIZE
DIMENSIONS
ORDER BY PART
NUMBER
MALE
FEMALE
E MIN
F HEX
BRASS
316SS
2RBP1 [ ]
18
116
316
716
7000
12,200
4RBP2 [ ]
18
932
916
4200
7300
6RBP2 [ ]
38
18
118
1132
6600
11,400
6RBP4 [ ]
38
118
38
4200
7300
8RBP4 [ ]
1532
716
78
5700
9300
8RBP6 [ ]
38
1532
716
78
2900
4800
12RBP4 [ ]
1732
716
1116
7300
13,100
12RBP6 [ ]
38
1916
3764
1116
5200
9400
12RBP8 [ ]
1916
58
1116
4000
7300
16RBP8 [ ]
1916
2332
138
5600
9500
16RBP12 [ ]
78
138
3200
5400
DIMENSIONS
FEMALE
E MIN
F HEX
BRASS
316SS
2CGP [ ]
18
1316
1132
916
4200
7300
4CGP [ ]
118
716
4200
7300
6CGP [ ]
38
3764
78
3400
5500
8CGP [ ]
2332
1116
2700
4900
12CGP [ ]
1916
5964
2100
3700
16CGP [ ]
1164
158
2500
4300
DIMENSIONS
ORDER BY PART
NUMBER
FEMALE
MALE
E MIN
F HEX
BRASS
316SS
4RCGP2 [ ]
18
1132
4200
7300
6RCGP4 [ ]
38
138
716
78
3400
5500
8RCGP4 [ ]
716
1116
2700
4900
8RCGP6 [ ]
38
3764
1116
2700
4900
12RCGP4 [ ]
12332
716
2100
3700
12RCGP6 [ ]
38
2116
3764
2100
3700
12RCGP8 [ ]
2116
2332
2100
3700
16RCGP8 [ ]
2316
2332
158
2500
4300
16RCGP12 [ ]
5964
158
2500
4200
PIPE SIZE
DIMENSIONS
FEMALE
F HEX
316SS
2CPP [ ]
18
1116
916
4200
7300
4CPP [ ]
78
4200
7300
6CPP [ ]
38
1132
78
3400
5500
8CPP [ ]
1116
2700
4900
12CPP [ ]
1716
2100
3700
16CPP [ ]
158
158
2500
4300
DIMENSIONS
MALE
F HEX
1PP [ ]
116
4764
516
2PP [ ]
18
716
4PP [ ]
1516
916
6PP [ ]
38
1116
8PP [ ]
78
12PP [ ]
1516
1116
16PP [ ]
11116
138
Dimensions for reference only. Subject to change.
HOKE
ORDER BY PART
NUMBER
DIMENSIONS
FEMALE
E MIN
BRASS
316SS
2FLP [ ]
18
1132
3600
5600
4FLP [ ]
2732
716
1116
2900
4600
6FLP [ ]
38
3764
1316
2300
3700
8FLP [ ]
118
2332
2200
3500
12FLP [ ]
5964
2200
3400
ORDER BY PART
NUMBER
W-Wrench Flat
FEMALE
E MIN
BRASS
316SS
116
2332
18
716
5000
7900
1SLP [ ]
DIMENSIONS
2SLP [ ]
18
2532
316
3600
5600
4SLP [ ]
2732
118
932
1116
2900
4600
6SLP [ ]
38
38
1316
2300
3700
8SLP [ ]
118
11132
1532
2200
3500
12SLP [ ]
1716
58
2200
3400
DIMENSIONS
ORDER BY PART
NUMBER
FEMALE
REDUCED
FEMALE
E MIN
BRASS
316SS
6RSLP4 [ ]
38
118
932
1316
2300
3700
8RSLP4 [ ]
118
932
2200
3500
8RSLP6 [ ]
38
1532
1332
3600
5600
HOKE
DIMENSIONS
MALE
E MIN
BRASS
316SS
2MLP [ ]
18
2332
316
716
6200
9700
4MLP [ ]
6164
932
1116
5000
7800
6MLP [ ]
38
38
1116
4800
7500
8MLP [ ]
1316
1532
4700
7400
12MLP [ ]
58
4400
6900
DIMENSIONS
FEMALE
E MIN
BRASS
316SS
2FTP [ ]
18
1132
3600
5600
4FTP [ ]
11116
2732
716
1116
2900
4600
6FTP [ ]
38
3764
1316
2300
3700
8FTP [ ]
118
2332
2200
3500
12FTP [ ]
278
1716
5964
158
4200
7900
ORDER BY PART
NUMBER
PIPE SIZE
E MIN
BRASS
316SS
2STP [ ]
18
11732
2532
316
3600
5600
4STP [ ]
12732
2732
932
1116
2800
4500
6STP [ ]
38
218
118
38
1316
2300
3700
8STP [ ]
21532
118
11132
1532
2200
3500
12STP [ ]
3764
1716
158
58
158
3800
7200
DIMENSIONS
PIPE SIZE
BRASS
316SS
2FT/BM2 [ ]
18
11116
2732
2732
316
1116
6200
9700
4FT/BM4 [ ]
11116
2732
932
1116
2900
4600
6FT/BM6 [ ]
38
118
38
1316
2300
3700
8FT/BM8 [ ]
118
11132
1532
2200
3500
DIMENSIONS
MALE
E MIN
BRASS
316SS
2MTP [ ]
18
316
716
6200
9700
4MTP [ ]
932
1116
5000
7800
6MTP [ ]
38
38
1116
4800
7500
8MTP [ ]
21732
11764
1532
4700
7400
12MTP [ ]
58
4400
6900
HOKE
DIMENSIONS
FEMALE
E MIN
BRASS
316SS
2CSP [ ]
18
11116
2732
1132
1116
6900
10,800
4CSP [ ]
11116
2732
716
1116
2800
4500
6CSP [ ]
38
3764
4600
7200
8CSP [ ]
118
2332
2200
3500
Safety Instructions
1. Do not tighten or loosen any part of a fitting or valve when the system is pressurized. Make sure the system is not pressurized
when tightening or loosening a fitting or valve connection.
2. Do not loosen HOKE GYROLOK nut or any product component in order to relieve or bleed down system pressure.
3. Do not exceed pressure-temperature specifications stated in the appropriate catalog.
4. When the application involves use of a toxic or hazardous fluid, exercise extra caution during operation and maintenance.
5. Before assembling new, unused HOKE GYROLOK tube fitting ends, loosen the HOKE GYROLOK nut before inserting
the tube to allow full insertion of the tube to the base of the body bore.
6. Always use tubing that is compatible with the fitting or valve material. Tubing appropriate for use with HOKE products is
described in HOKEs Tubing Data Charts. For example, use 316 Stainless Steel fittings with 316 Stainless Steel tubing.
7. Always leave a length of straight tube between the tube bend and the fitting. A tube bent too close to the fitting connection
may be a source of leakage.
8. During assembly of the HOKE GYROLOK tube end, always hold the fitting or valve body with one wrench while separately
wrench tightening the HOKE GYROLOK nut. Follow the same precaution when disassembling.
9. Always use a HOKE tube insert (basic part number T1) when assembling a HOKE GYROLOK fitting to soft, pliable plastic tubing.
10. Always use proper thread lubricants or sealants on tapered pipe threads. Note that thread sealants may have lower
temperature ratings than the basic fitting.
11. When installing an NPT ended valve, hold the valve body near the connection with one wrench, while separately wrench
tightening the mating pipe. Turn the pipe, not the valve. Follow the same precaution when disconnecting.
12. Do not hold the valve handle when tightening an end connection.
13. Do not use excessive force to open or close a Ball Valve, e.g., Do not use a handle extension.
14. On initial installation, valves may require an adjustment of the packing nut due to storage variations, systems parameters, and
cold flow properties of TFE.
FOR YOUR SAFETY: It is solely the responsibility of the system designer and user to select products suitable for their specific
application requirements and to ensure proper installation, operation, and maintenance of these products. Material compatibility, product ratings and application details should be considered in the selection. Improper selection or use of products
described herein can cause personal injury or property damage.
8
HOKE
CIRCOR Instrumentation Technologies (CIT) is the logical choice for fluid control solutions.
We provide the lowest cost of ownership, offering the best in class reliability and
availability of our products. We have global coverage, delivering value in the form of local,
flexible service to meet our customers needs. CIT is a product group specializing in
instrumentation with orifice sizes typically up to 2.