Académique Documents
Professionnel Documents
Culture Documents
800XA
SAFETY SUMMARY
All safety related codification, symbols and
instructions that appear in this operating instruction
manual must be strictly observed to ensure operator as
well as equipment safety. The instruction manual is
meant for personnel involved in wiring, installation,
operation and routine maintenance of the
equipment.
If the equipment related above safety measures are
not practiced, the manufacturer does not have any
liability for human or equipment safety.
! CAUTION: Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
SPECIFICATIONS
SUPPLY
VOLTAGE
DELAY MODES
TIME RANGES
OUTPUT
CONTACT
ACCURACY
LED INDICATION
MAINTENANCE
20V to 240V AC (AC : 50 or 60 Hz) 1. The power supply should be switched off before
removing the equipment for cleaning. Ensure that no
.12V to 240 VDC
parts are charged.
On delay / Interval
2. Clean the equipment with a clean, soft cloth
soaked in water. Do not use any other cleaning
3 /10/30/60 sec./ Min
agent other than the one specified by
2C/O (5A@250V AC/24V DC)
manufacturer.
Resistive
INSTALLATION GUIDELINES
RESET
On interruption of power.
Reset time : Less than 100 ms.
RELAY RATING
5 A @ 250 V AC / 24 VDC,
resistive.
MOUNTING
TEMPERATURE
Operating: 0 to 500C,
Storage: 0 to 500C.
HUMIDITY
HOUSING
ABS plastic
WEIGHT
129 grams.
! CAUTION:
PANEL DIMENSIONS
22.5m m
8 9
10
ON
2 1
80
35 75
mm mm
75
mm
6
5
4
4.
11.5mm
61.0mm
10
101mm
85mm
Mounting holes
WIRING GUIDELINES
A1 25
CAUTION:
1. The power should be turned off while wiring and
maintenance to prevent the risk of electric shock.
Do
not touch the terminals when power is ON.
2. Wiring shall be done strictly according to the
terminal layout with shortest connections. Confirm
that all the connections are correct.
3.Use lugged terminals to meet M3 screws and
ensure that the screws are tightened .
(L)
15
(COM1) 26
LOAD 1
A2
CONTACTOR
NO
COM
A1
16 28
(NC1)
C
R
Snubber
18 A2
(NO1)
(N)
TERMINAL CONNECTIONS
1) Snubber Part No.: APRC - 01.
2) MOV Part No.: AP-MOV - 03.
Note: Use snubber as shown above to increase the life
of internal relay.
A1 25
15 26
S
U
P
P
L
Y
COM
NC
NO
NC
COM
NO
DIR
MODE
ON DELAY
16 28
INTERVAL
18 A2
ON DELAY
INTERVAL
POWER
t
A1
A2
15
COM
16
NC
18
NO
t = Set time
TIMER SUPPLY
TIMER SUPPLY
RELAY
CONTACT
SWITCH SETTINGS
1
230VAC
RELAY
DESCRIPTION
TERMINAL
RANGE
RANGE
3 SEC
3 MIN
10 SEC
10 MIN
30 SEC
30 MIN
60 SEC
60 MIN
A1 25
15 26
(COM1)
Snubber
C
R
L
O
A
D
1
(L)
Tel:91-22-28476443, Fax:91-22-28471733,
Website: www.selec.com
E- mail: sales@selec.com.
Document name: Operating/0711/800XA/ Version 1
16 28
(NC1)
18 A2
(NO1)
(N)
OP217-V01