Table of contents

page
HISTORY

r&d

Services

CHILLED WATER

12

AQF

Fan coil unit

12

KOG

4-way chilled water cassette

14

HAW

Hi-wall chilled water unit

16

WATER console
CAO

18
18

Water console

WATER condensing unit


GCAO

20
20

Water condensing unit

SPLIT DX

22

FAF

Floor ceiling

22

CAF

Cassette 600x600

24

CAF

Cassette 900x900

26

DAF

Ducted

28

DK DN

Air to air split system

30

VERTICAL CABINET

34

X AR

Vertical air cabinet

34

X AO

Vertical water cabinet

36

ROOFTOP
HAN

38
38

Rooftop unit

One Group,
one history,
many ambitions

2012 will mark the 65th


anniversary of the Groups
activity and international
expansion.
The Airwell Group has a long history,
marked by innovations at every
stage of its development. In 1947
Paul Wallet founded the company
LAir Conditionn Entreprise (ACE)
near Paris and, with the brand
Airwell, quickly became the leading
manufacturer of direct-expansion air
conditioners. The foundations had
been laid for what would become
one of the largest groups worldwide
to offer solutions for both the
residential sector and to businesses,
industry and the service sector.

Industrial beginnings
Since the 1950s, ACE has been mass-producing air conditioning systems for
private and commercial use. At that time, the company designed the first window
unit one of its flagship products intended for the European and African markets.

A decade of innovation
Moving forward, in 1970 Airwell split its window unit into two parts to form a split
system unit, becoming the first European manufacturer to produce this product.
Another string was added to its bow a few years later, in 1979, with the air-water
heat pump. In the wake of the two oil crises, this system could be connected to
existing fuel oil boilers in homes. And in 1982 Airwell came up with the first range
of wall split systems, incorporating a remote control, a high-tech tangential flow
turbine to reduce noise levels and rotary compressors.

Ongoing expansion
Always at the cutting edge of technology, in 1988 Airwell became the first western
company to develop the Inverter system, which varies the speed of the compressor,
thus enabling the temperature to be adjusted and energy savings to be made. In the
1990s, the company experienced exceptional growth, resulting in the creation of its
historic factory in Tillires-sur-Avre, Normandy, and the acquisition of distributors
in Spain, Italy, Germany and France.

An international dimension
In 1997, Airwell joined the Israeli group, Elco Holdings, which is listed on the TelAviv stock exchange and is involved in many sectors: household appliances, air
conditioning, retail sale of electronics and real estate. Other acquisitions, between
1998 and 2001, most notably of factories in France, Italy and China, strengthened
the Groups international position. At the same time, it expanded its distribution
network to Argentina and Turkey. The first decade of the new millennium saw
acquisitions in Germany (Polenz Klimatechnik) and the USA (Fedders). Finally, to
strengthen its position on the Asian markets, the Airwell Group will open a new
factory in Taicang (China) in June 2012.

What does the future hold?


Many challenges lie ahead. The first is reliant on increasingly efficient, high quality
products and services, which means listening to customers and ensuring a local
presence. R&D is also one of the main priorities, with a desire to offer major
innovations every year for each business line.

R&D:
innovation and
performance
To encourage innovation, the Airwell Group has stepped up its
R&D activity in the development of technologies designed for
maximum comfort, air purification and considerable energy
savings.
Innovation is vital to the Airwell Groups expansion. Having led the field since the
1950s in mass-production of the first window unit, in 1970 it developed a split
system unit, becoming the the first European manufacturer of this product, to
which new functions have been added over the years: remote control, high-tech
tangential flow turbine to reduce noise levels, rotary compressors, etc. And lets
not forget the air-water heat pump that the Group developed in 1979.

An extensive, diverse range of solutions


Today, with a Research & Development (R&D) department with 150 engineers in
France, Italy, China, Hong Kong and Israel and with a dedicated budget up 40% in
2011, the Airwell Group places a great deal of emphasis on innovation! The result?
With more than 600 products designed for all types of installation, we are the only
company to offer such a vast range for the residential sector and for business,
industry and the service sector. A whole host of full solutions to meet every need:
> commercial: applications that lend themselves to the specific nature of each
building;
> residential: heating, cooling, dehumidification, air purification;
> industrial: water or air condensation units, air treatment units, roof units.

The efficiency of the DC Inverter


This approach results in constant product optimisation thanks to the implementation
of cutting-edge technologies. The Airwell Group was the first in Europe to introduce
the DC Inverter in 1988. This system enables compressor speed to be adapted to
the desired room temperature through continuous operation that allows the power
of the compressor to be adjusted. In this way, as soon as the set temperature is
reached the speed is reduced. As well as resulting in energy savings in the region
of 30%, this makes the system more versatile and quieter.

The Sterionizer
for indoor air treatment

MULTI LAYER
AIR PURIFICATION SYSTEM

Another patented technology is changing the future of


air conditioning and illustrates the Airwell Groups desire
for innovation. This technology is bipolar ionisation, also
known as Sterionizer. This system generates negative
and positive oxygen ions like those found in nature
causing an electrical chemical reaction that eradicates
viruses, bacteria, fungi, mildew, etc. It purifies the air inside
the home, neutralises odours and significantly reduces
allergies to dust mites. Air as healthy as in the heart of
the forest! A whole host of health benefits that have been
confirmed by internationally renowned research institutes.
The Sterionizer also has the advantage of being compatible
with air conditioners, fans, humidifiers and dehumidifiers
as well as cooling systems.

Odours
Pollen
Dust
Bacteria

Pre-filters
Filters courses
dust before
entering the unit

Smoke

Cutting-edge, environmentally friendly


technology
Sustainable development and respect for the environment are priorities that
are incorporated into the manufacturing process across the Airwell range.
Pre-empting legislation and energy regulations, the Group offers products
that comply fully with European and international standards. Furthermore,
the use of advanced technologies helps to reduce the products energy
consumption and noise levels.

Nano Photocatalyst +
Antibacterial/
Electrostatic
Eliminates dust, smoke,
odour and bacteria

Super plasma
Eliminates remaining
bacteria + energizes
your air to feel well

Healthy fresh natural air

Efficient
services
for quality
follow-up

To overcome installation
and after-sales problems,
Airwell has set up high
quality services.
Keeping our customers
happy and meeting all of their
expectations about our products
is our TOP priority. With this
in mind, Airwell is committed
to continuously improving
its service to professional
customers, a policy broken
down into three main areas:
training, spare parts and
technical support.

Training towards expertise


For Airwell, well-trained professional clients mean successful installations! They are
given regular training in order to furnish them with the technical expertise they need
to the select the product most suited to the needs of the end user.
For approved Service Centers, training focuses on commissioning as well as
maintenance and repair work. Generally speaking, the programmes designed for
them are built around the following topics.
Service centers

Installation engineers
Product presentation and selection
Technical description
Product installation and use

>
>
>

Commissioning
Servicing/Maintenance
Repairs

This training combines theoretical classroom presentations and practical work on


teaching benches to recreate real-life situations.

Spare parts: optimum response times


The supply of original Airwell spare parts is highly significant for the reliability and
sustainability of our installations. With this in mind, we set up a European spare parts
centre in Tillires-sur-Avre, in the Eure dpartement, on the site of one of our French
factories. With more than 12,000 different products in stock and highly responsive
teams, we can deliver parts within 48 hours of order entry and confirmation (subject to
availability and specific weight and size constraints). Parts may be available up to ten
years after a product has been discontinued (air-water heat pumps and VRF ranges).
Contact the Spare Parts Department:
by telephone or email to your dedicated contact;
by fax on +33 (0)2 32 32 50 33;
by post at the following address:
AIRWELL France SAS, Spare Parts Department,
Route de Verneuil, 27570 Tillires sur Avre.

Technical support to meet


any requirement
Airwell has a network of more than 150 approved Service Centers throughout France,
which receive regular product training. Authorised to commission heat pumps and
reversible air conditioners, they can also offer maintenance contracts to end users.
A worldwide network of Service Centers is also under development.
In addition, between 8.30am and 12.30pm and 2pm and 5.30pm Monday to Friday,
a technical support hotline is manned by a team of Airwell technicians. They can
answer questions relating to the installation, commissioning and repair of products
sold by Airwell. Call them on +33 (0)1 39 44 65 79.
For specific questions requiring more in-depth knowledge, technical consultants can
visit the site of an end user to investigate the problem with the installation engineer and
the distributor.

chilled water
water source
heat pump
split dx

Page
Fan Coil Unit

AQF

12

4-way chilled
water cassette

KOG

14

Hi-wall chilled
water unit

HAW

16

WATER CONSOLE

CAO

18

Water Source

GCAO

20

Floor Ceiling

FAF

22

Cassette
600x600

CAF

24

Cassette
900x900

CAF

26

Ducted

DAF

28

DK DN

30

vertical
air cabinet

X AR

34

vertical
water cabinet

X AO

36

rooftop unit

HAN

38

vertical
cabinet

air to air
split system

rooftop

Light Commercial Range

AIRWELL range

Model Name

10

7
2 kW

9
2.5 kW

12
3.5 kW

18
5 kW

21
6.2 kW

24
6.8 kW

11

30
7.8 kW

36
10 kW

45
12.5 kW

>14 kW

Light Commercial |

Aqu@Fan

Fan Coil Unit - cooling and heating


Cooling Capacity: from 1.1 to 9.0 kW
Heating Capacity: from 1.2 to 11.6 kW
Sizes: 7
Versions:
2-Pipes
2-Pipes/2-Wires
4-pipes
Configurations:
Vertical console with cabinet
Vertical concealed without cabinet
Ceiling exposed with cabinet
Ceiling concealed without cabinet

PRODUCT ADVANTAGES

Main Options

 ase of installation.
E
Harmonious and aesthetic RAL9010 painted cabinet
design.
Streamlined design and elaborate finish enabling
harmonious integration.
5-speed AC fan.
Very low operating acoustical levels.
Airflow rate between 140 and 1.400 m3/h.
Selection of service side.
Coil with hydrophilic blue fins for condensate flow
improvement.

 -row coil for optimized cooling performances.


3
Electrical heater with inserted heating rod.
AC motor.
Selection of 3 speed.
Large choice of control: Electro-mechanic, electronic,
on-board or wall-mounted.
3-way ON/OFF valve.
G2 filter.

Main Accessories
 alve.
V
Control.
Auxiliary drain pan.
Condensate drain pump.
Feet.
Grille between feet.

AIRWELL SOLUTIONS

Operating limit for Standard unit


Minimum water temperature

+6C

Maximum water temperature

+90C

Maximum operating pressure

17 bars

Minimum indoor air temperature (room/intake/around unit)

5C/15% RH

Maximum indoor air temperature (room/intake/around unit)

32C/70% RH

12

Aqu@Fan technical data


2Pipe
without valve

4Pipe
without valve

2Pipe/2Wire
without valve

AQUAFAN II Size
Product codes:
Vertical Console AWC
Vertical Concealed AWN
Horizontal Console AHC
Horizontal Concealed AHN
Vertical Console AWC
Vertical Concealed AWN
Horizontal Console AHC
Horizontal Concealed AHN
Electrical heater W
Vertical Console AWC
Vertical Concealed AWN
Horizontal Console AHC
Horizontal Concealed AHN

2Pipe with 3-w valve


+ Aqu@net + RCL + feet
2Pipe/2Wire with 3-w valve
+ Aqu@net + RCL + feet
CAPACITIES - 2-Pipe
Cooling (1)
Heating (2)
CAPACITIES - 4-Pipe
Cooling

(1)

Heating (3)

20

30

40

50

60

70

80

7OG033010
7OG033034
7OG033058
7OG033082
7OG033026
7OG033050
7OG033074
7OG033098
600
7OG033018
7OG033042
7OG033066
7OG033090

7OG033011
7OG033035
7OG033059
7OG033083
7OG033027
7OG033051
7OG033075
7OG033099
600
7OG033019
7OG033043
7OG033067
7OG033091

7OG033012
7OG033036
7OG033060
7OG033084
7OG033028
7OG033052
7OG033076
7OG033100
1000
7OG033020
7OG033044
7OG033068
7OG033092

7OG033013
7OG033037
7OG033061
7OG033085
7OG033029
7OG033053
7OG033077
7OG033101
1200
7OG033021
7OG033045
7OG033069
7OG033093

7OG033014
7OG033038
7OG033062
7OG033086
7OG033030
7OG033054
7OG033078
7OG033102
1500
7OG033022
7OG033046
7OG033070
7OG033094

7OG033015
7OG033039
7OG033063
7OG033087
7OG033031
7OG033055
7OG033079
7OG033103
1500
7OG033023
7OG033047
7OG033071
7OG033095

7OG033016
7OG033040
7OG033064
7OG033088
7OG033032
7OG033056
7OG033080
7OG033104
1800

Vertical Console AWC

7OG033113

7OG033114

7OG033115

Electrical heater W
Vertical Console AWC

600
7OG033116

600
7OG033117

1000
7OG033118

Total cooling capacity


Sensible capacity
Water flow
Water pressure drop
Heating capacity

W
W
l/h
kPa
W

1870
1480
321
8
2530

2440
1940
418
16
3400

3460
2730
594
33
4570

4220
2980
725
29
5410

5730
3850
983
42
7360

7210
5640
1243
25
9180

9040
6890
1548
39
11300

Total cooling capacity


Sensible capacity
Water flow
Water pressure drop
Heating capacity
Water flow
Water pressure drop

W
W
l/h
kPa
W
l/h
kPa

1970
1520
338
42
2320
204
6

2390
1880
411
15
3340
292
13

3400
2660
583
31
4540
398
25

4220
3000
724
20
5250
460
50

5610
3770
961
40
6060
531
15

7120
5540
1228
24
6980
611
24

8830
6710
1516
38
11600
1014
48

Sound power level


Sound pressure level (4)
NR (4)
Sound pressure level (5)
NR (5)

dB(A)
dB(A)
dB(A)
dB(A)
dB(A)

34/43/53
26/35/45
22/31/41
<15/24/32
<15/19/28

37/48/56
29/40/48
24/36/44
16/27/35
<15/23/31

37/42/52
29/34/44
24/29/39
16/21/31
<15/16/26

37/45/55
29/37/47
23/33/43
16/24/34
<15/20/30

43/52/61
35/44/53
31/39/48
22/31/40
18/26/35

46/54/65
38/46/57
34/41/52
27/35/44
23/30/39

49/56/66
41/48/58
36/44/54
28/35/45
23/31/41

Number
Airflow

m/h

1
132/223/317

1
181/290/407

2
295/385/570

2
333/471/736

2
468/650/917

2
545/799/1150

3
665/934/1376

Power supply
Fan consumption
Electrical heater (max)

V/Ph/Hz
W
16/27/45
W
900

24/40/60
1200

33/39/57
2000

230/1/50
39/45/66
2400

41/64/107
3000

92/110/150
3000

90/112/188
3600

SOUND LEVELS (LS/MS/HS)


Console
Concealed
FANS (LS/MS/HS)

ELECTRICAL (LS/MS/HS)

WATER CONNECTIONS
Type

1/2 Gas Female Threaded

DIMENSIONS
Console (LxWxH)
Concealed (LxWxH)

mm
mm

768x478x231
510x430x220

953x478x231
695x430x220

1138x478x231 1323x478x231 1508x478x231 1323x578x231 1508x578x231


880x430x220 1065x430x220 1250x430x220 1065x530x220 1250x530x220

Console
Concealed

kg
kg

20
14

23
16

30
23

WEIGHT
35
27

39
30

42
34

50
41

ACCESSORies CODE
VALVE 4V/TOR/2T + DRAIN PAN
VALVE 4V/TOR/4T + DRAIN PAN
AUX DRAIN PAN
PRC DRAIN PUMP
FEET - MP

Vertical AWC/AWN
Horizontal AHC/AHN
Vertical AWC/AWN
Horizontal AHC/AHN
Vertical AWC/AWN
Horizontal AHC/AHN (Left)
Vertical AWC/AWN
Cabinet AWC/AHC
Concealed AWN / AHN
Cabinet AWC/AHC

GRILL MPG
TRM-FA
TRM-VP
Aqu@net
AQUASIMP + WPT Wall-mounted
KIT TAE 20 + SHE

7ACFH0561
7ACFH0562
7ACFH0564
7ACFH0565

7ACFH0585
7ACFH0586
7ACFH0588
7ACFH0589
7ACTL0394

7ACTL0446

7ACVF0330

7ACVF0331

7ACFH0603
7ACTL0391
7ACTL0415
7ACVF0332
7ACVF0333
7ACVF0334
7ACEL1440
7ACEL1443
7ACEL1432
7ACEL1546 + 7ACEL1547
7ACEL1452

(1) According to Eurovent standard: Air: 27C DB/19C WB , Water: 7C/12C.


(2) According to Eurovent standard: Air: 20C, Water : 50C, same water flow as in cooling.
(3) According to Eurovent standard: Air: 20C, Water: 70C/60C.
(4) Sound pressure for console unit considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.
(5) Sound pressure for concealed unit considering an hypothetical installation and local attenuation of 21 dB(A).

13

7ACTL0448

7ACVF0333

7ACVF0334

Light Commercial |

KOG

4-way chilled water cassette


cooling and heating
Cooling Capacity: from 1.6 to 10.2 kW
Heating Capacity: from 1.8 to 11.6 kW
Sizes: 5
Versions:
2-Pipes
2-Pipes/2-Wires
4-pipes
Configuration: Cassette

PRODUCT ADVANTAGES

Main Options

 esigned for suspended ceiling integration.


D
600x600 (9, 12 and 18 models) and 600x1200 formats
(30 and 45 models).
Low built-in height: 287 mm.
Direct access to electrical connection on sliding
chassis.
Integrated valve and electrical connections.
5-speed AC fan motor.
Very low operating acoustical levels with new low
noise LN versions (9, 12 and 18 models).
Fresh air supplied.
Air distribution in adjacent room.
Integrated condensate drain lift pump up to 600 mm.
Infra-red remote control version with valve and
change-over.
Galvanized steel sheet with thermal and acoustical
insulation, avoiding condensation on the casing and
providing good sound attenuation.
Possibility to close one or two discharge flaps.
Cleanable synthetic-type air filter.
Coil with hydrophilic blue fins for condensate flow
improvement.

 lectrical heater with inserted heating rod.


E
AC motor.
Selection of 3 speed.
Aqu@net control or terminal block for wall-mounted
thermostat.
2-way or 3-way ON/OFF valve.
G1 filter.

Main Accessories
 alve.
V
Aqu@net control.
Wall-mounted thermostat.
Solid ceiling frame.
Auxiliary condensate drain pan.
Master and slaves control, up to 4 units max.

AIRWELL SOLUTIONS

Operating limit for Standard unit


Minimum water temperature
Maximum water temperature
Maximum operating pressure

+3C
+70C (size 09-12-18)/
+60C (size 30/45)
15 bars

Minimum indoor air temperature (room/intake/around unit)

13C/15% RH

Maximum indoor air temperature (room/intake/around unit)

32C/70% RH

14

KOG technical data


KOG Size 09 LN
2Pipe without valve
Code
2Pipe with 3-w valve
Code
2Pipe with 2-w valve
Code
2Pipe/2Wire with 3-w valve
Code
2Pipe IR with 3-w valve
Code
4Pipe without valve
Code
4Pipe with 3-w valve
Code
CAPACITIES - 2-Pipe

12 LN

18 LN

30

45

K 9 OG 2T SV
7OG052008
K 9 OG 2T AV
7OG052009
K 9 OG 2T AV2V
7OG052350
K 9 OG 2T CH AV
7OG052011
K 9 OG 2T IR AV
7OG102025
K 9 OG 4T SV
7OG052020
K 9 OG 4T AV
7OG052021

K 12 OG 2T SV
7OG052012
K 12 OG 2T AV
7OG052013
K 12 OG 2T AV2V
7OG052351
K 12 OG 2T CH AV
7OG052015
K 12 OG 2T IR AV
7OG102026
K 12 OG 4T SV
7OG052022
K 12 OG 4T AV
7OG052023

K 18 OG 2T SV
7OG052016
K 18 OG 2T AV
7OG052017
K 18 OG 2T AV2V
7OG052352
K 18 OG 2T CH AV
7OG052019
K 18 OG 2T IR AV
7OG102027
K 18 OG 4T SV
7OG052024
K 18 OG 4T AV
7OG052025

K 30 OG 2T SV
7SP041036

K 45 OG 2T SV
7SP041037

K 30 OG 2T IR AV
7OG101028

K 45 OG 2T IR AV
7OG101029
K 45 OG 4T SV
7SP041024

Nominal
Total cooling capacity

2300

3500

4600

6440

10190

Sensible capacity

1800

3000

3850

4830

7750

Water flow

l/h

400

600

790

1208

1753

Water pressure drop

kPa

12

18

16

17

23,5

Heating (2)

Heating capacity

3100

4500

5700

8050

11600

CAPACITIES - 4-Pipe

Nominal
Total cooling capacity

2300

3500

4600

10100

Sensible capacity

1800

3000

3850

7254

Water flow

l/h

400

600

790

1737

Water pressure drop

kPa

12

18

16

27

Heating capacity

2200

3335

4470

6670

Water flow

l/h

210

287

380

758

Water pressure drop

kPa

13

28

27

Sound power level

dB(A)

34/40/50

34/40/50

35/41/49/57

47/50/57

47/53/59

Sound pressure level (4)

dB(A)

26/32/42

26/32/42

27/33/41/49

39/42/49

39/45/51

NR (4)

dB(A)

20/27/37

20/27/37

23/28/35/43

34/37/44

34/40/45

330/450/720

330/450/720

290/410/580/830

1100/1350/1550

1000/1250/1630

Cooling (1)

Cooling

(1)

Heating (3)

SOUND LEVELS (LS/MS/HS)

FANS (LS/MS/HS)
Number
Airflow

m/h

ELECTRICAL (LS/MS/HS)
Power supply

V/Ph/Hz

Fan consumption

20/30/50

20/30/50

21/30/46/71

230/1/50
165/180/200

151/170/180

Electrical heater

1500

1800

2400

NA

NA

Cooling coil

inches

1/2"

1/2"

3/4"

1"

1"

Heating coil

inches

1/2"

1/2"

1/2"

NA

1/2"

Casing (LxWxH)

mm

571x571x287

1171x571x287

Grille (LxWxH)

mm

625x625x40

1225x625x40

Unit weight

kg

WATER CONNECTIONS
Type

Gas male threaded

DIMENSIONS

WEIGHT
26

28

29

49

55

7ACFH0051

7ACFH0052

ACCESSORies CODE
TRM-VP

7ACEL1443

TRM-FA

7ACEL1440
7ACEL1432

Aqu@net

7ACEL1546 + 7ACEL1547

AQUASIMP + WPT (Wall-mounted)

7ACEL1452

TAE20+SEH

7ACEL1207

Relay kit
with 3-w valve + condensate tray - 2P -

with 3-w valve + condensate tray - 4P -

7ACFH0122

Drain Pan - 2P

7ACTL0083

7ACTL0005

7ACTL0005

Drain pan - 4P

7ACTL0083

7ACTL0040

Special frame for solid ceiling

7ACVF0091

(1) According to Eurovent standard: Air: 27C DB/19C WB , Water: 7C/12C.


(2) According to Eurovent standard: Air: 20C, Water : 50C, same water flow as in cooling.
(3) Air: 20C, Water: 60C/50C.
(4) Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.

15

Light Commercial |

H@Wair

Hi-wall chilled water unit


cooling and heating
Cooling Capacity: from 1.6 to 4.7 kW
Heating Capacity: from 2.1 to 5.9 kW
Sizes: 4
Version: 2-Pipes
Configuration: Hi Wall

PRODUCT ADVANTAGES

Main Options

 esthetic design suitable for home and hotel


A
applications.
Silent unit for optimum customer comfort.
Version with Integrated 3-way valve and IR control.
Choice between IR or wall-mounted thermostat.
Light unit for easy installation.
Very easy servicing through removable front plate.
Cleanable synthetic-type air filter.
Indoor unit compatible with all Airwell chilled water
production units.

 C-08A IR control.
R
Terminal block for wall-mounted thermostat.
Version with 3-way ON/OFF valve.
3-speed tangential fan motor.
Electro-static anti-bacteria filter.
Pipe connectors.
Drilling template.

Main Accessories
 alve.
V
Aqu@net control.
Wall-mounted thermostat.

Operating limit for Standard unit


Minimum water temperature

+5C

Maximum water temperature

+60C

Maximum operating pressure

15 bars

Minimum indoor air temperature (room/intake/around unit)

6C/15% RH

Maximum indoor air temperature (room/intake/around unit)

32C/70% RH

16

H@Wair technical data


H@Wair Size HAW007
2Pipe IR Without valve
Code
2Pipe IR With valve
Code
2Pipe Without valve
Code
CAPACITIES

Cooling (1)

Heating (2)

H@Wair 7 IR SV
AWFC-HAW007-A

H@Wair 7 TB SV
AWFC-HAW007-C

HAW009

HWA018

HAW022

H@Wair 9 IR SV
AWFC-HAW009-A
H@Wair 9 IR AV
AWFC-HAW009-B
H@Wair 9 TB SV
AWFC-HAW009-C

H@Wair 18 IR SV
AWFC-HAW018-A

H@Wair 22 IR SV
AWFC-HAW022-A
H@Wair 22 IR AV
AWFC-HAW022-B
H@Wair 22 TB SV
AWFC-HAW022-C

H@Wair 18 TB SV
AWFC-HAW018-C

Nominal
Total cooling capacity

2200

2900

3600

4700

Sensible capacity

1870

2400

3000

3700

Water flow

l/h

400

500

620

810

Water pressure drop

kPa

10

16

35

50

Heating capacity

2900

3700

4800

5850

SOUND LEVELS (LS/MS/HS)


Sound power level

dB(A)

36/40/44

38/42/48

45/48/52

50/54/58

Sound pressure level (3)

dB(A)

28/32/36

30/34/40

37/40/44

42/46/50

NR (3)

dB(A)

23/27/31

25/29/35

32/35/39

37/41/45

320/380/450

400/500/600

550/650/750

650/750/900

22/26/28

22/26/28

FANS (LS/MS/HS)
Number
Airflow

m/h

ELECTRICAL (LS/MS/HS)
Power supply

V/Ph/Hz

Fan consumption

230/1/50
25/28/31

43/47/58

WATER CONNECTIONS
Type

Gas female threaded

Coil

inches

Casing (LxWxH)

mm

Unit weight

kg

1/2"

1/2"

1/2"

1/2"

DIMENSIONS
845x275x180

940x298x200

WEIGHT
11

11

(1) According to Eurovent standard: Air: 27C DB/19C WB , Water: 7C/12C.


(2) According to Eurovent standard: Air: 20C, Water : 50C, same water flow as in cooling.
(3) Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.

AIRWELL SOLUTIONS

17

13

13

Light Commercial |

CAO

Water Console - cooling only


Cooling Capacity: from 2.3 to 4.7 kW
Refrigerant: R-407C
Sizes: 3
Configuration: Monobloc system

PRODUCT ADVANTAGES

Main Accessories

Ideal solution for premises where it is impossible


to install an outdoor unit.
Easy installation and maintenance.
Public or recycled water operation.
Modulating regulation valve for reducing water
consumption.
Possibility of Fresh air supplied.
Rotary compressor.
Reusable air filters.

 emote control.
R
Electric heater.

Operating limit for Standard unit


Minimum air temperature

15C DB/ 10C WB

Maximum air temperature

32C DB/ 23C WB

Minimum water temperature (wasted/recycled)

+10C / 20C

Maximum water temperature (wasted/recycled)

+30C / 44C

18

CAO technical data


CAO 230
Code 7CW011016

CAO 370

CAO 580

7CW011017

7CW011018

CAPACITIES
Cooling

Cooling capacity

kW

2.3

3.0

4.7

Power input

kW

0.66

0.85

1.30

3.4

3.5

3.6

EER
VENTILATION
Airflow range (min/max)

m/h

450/550

450/550

725/880

Fresh Airflow

m/h

60

60

80

Water flow

l/h

130

170

270

Sound pressure level (4m) (min/max)

dB(A)

37/40

38/41

41/43

HYDRAULIC
SOUND LEVELS
POWER SUPPLY
Power supply

230/1P/50 Hz

DIMENSIONS
LxWxH

mm

1030x226x620

1030x226x620

1390x226x620

Unit weight

kg

48

49

69

kW

Code

7ACEL0006

7ACEL0006

7ACEL0007

Remote control Code

7ACEL0039

7ACEL0039

7ACEL0039

WEIGHT
ACCESSORIES
Electric heater

AIRWELL SOLUTIONS

19

Light Commercial |

GCAO

Water condensing unit


 ater condensing unit with capacities from 2.7
W
to 6.4 kW.
Cooling only.
Sizes: 4.
Refrigerant: R410A.

PRODUCT ADVANTAGES

Main Options

 ater flow protection by pressostat valve.


W
High pressure switch with manual reset.
Super quiet.
Connection to HHF 9-12-18-24 indoor units.
Ideal solution for premises where it is impossible to
install an outdoor unit.
Connection to recycled or lost water systems.
Water intake and drainage via public water network.
Pressostat valve supplied (to limit water consumption).
High Pressure safety pressostat valve with manual reset.
Low sound emission value.

20

 igh efficiency and energy saving product.


H
R410A fluid.
Oxidize and degrade organic contaminants. It can
effectively eliminate 99.9% of bacteria and collect
dust effectively.
Remove in high efficient small particles from the air
and purify the air from bacteria.
Avoid bacteria and mildew growing by keeping the
heat exchanger dry after cooling operation.
Precise temperature control around dedicated area
by using remote control temperature sensor.
Better cooling and heating affect by extending the air
distribution in the room in a wide angle.
Improve cooling and heating affect by swing the air
up and down automatically.
Adjusting the room temperature along the night
follow human sleep behaviour.
Boosting the output capacity and create a rapid
reaction to reach the room temperature set up.
Option to set up the stop and operation.
Indication to replace the remote control battery.
Automatic restart the unit in the last operation mode
once resume power supply.
Lock the remote control function to avoid non
required operation.
Slim and small size to reduce the unit space required
and provide esthetic image.
Super Plasma.

GCAO technical data


Outdoor units
Cooling

GCAO 9N

Pipe Line

COOLING
Indoor
unit

GCAO 24N

Capacity

kW

2.7

3.4

5.57

6.37

kW

0.73

1.03

1.39

1.93

3.70/A

3.30/B

4.01/A

3.30/B

Operating limits indoor temperature

17/32 Dry Bulb

Condenser inlet water temperature

10/45

Sound power level to 1 m

dB(A)

49

49

51

53

Waste water flow at + 15C

l/h

120

160

250

320

Recycled water flow 30/35C

l/h

Compressor type

Power
supply
1~230V - 50 Hz

GCAO 18N

Input power
EER/Energy Label

Outdoor
unit

GCAO 12N

600

850

1 250

1 550

Rotary

Rotary

Rotary

Rotary

Dimensions (WxDxH)

mm

625x360x473

625x360x473

625x360x473

625x360x473

Weight

kg

41

45

50

56

Part number

7SP101040

7SP101041

7SP101045

7SP101044

Power supply side

Outdoor

Outdoor

Outdoor

Outdoor

Power cable section

mm

3x1.5

3x1.5

3x1.5

3x2.5

Fuse rating am

10

10

10

16

Electrical connections

mm2

3x1.5

3x1.5

3x1.5

4x2.5

Suction pipe diameter

inches 3/8

3/8

1/2

5/8

Liquid pipe diameter

inches 1/4

1/4

1/4

3/8

Max length

25

25

25

25

Max height

15

15

15

15

Indoor units

AWSI-HHF009-N11

AWSI-HHF012-N11

AWSI-HHF018-N11

AWSI-HHF024-N11

Capacity

kW

2.64

3.22

5.3

6.15

Sound pressure level to 1 m (LS/MS/HS/SS) dB(A)

32/35/37/40

32/35/38/41

35/39/42/45

38/41/44/47

Sound power level(LS/MS/HS/SS)

dB(A)

42/45/47/50

42/45/48/51

45/49/52/55

48/51/54/57

Dehumidification

l/h

0.8

1.2

1.8

Airflow (LS/MS/HS/SS)

m3/h

310/340/370/400

350/420/500/550

550/650/780/850

550/650/780/850

Dimensions (WxDxH)

mm

730x174x255

790x177x265

940x200x298

940x200x298

Weight

kg

13

13

7SP022856

7SP022857

7SP022858

7SP022859

Part number

AIRWELL SOLUTIONS

21

Light Commercial |

FAF

Floor Ceiling

RC08A

 loor and ceiling line available in capacities from


F
3.5 to 12 kW.
Cooling & heating operation mode.
Precise temperature control around dedicated
area by using remote control temperature sensor.
Available in 3PH from 10 kW.

RCW3

RCW4
(optional)

PRODUCT ADVANTAGES

Main Options

 ired and wireless remote controls provided as


W
standard.
Self diagnostic (error indications) in remote the wired
remote control for ease of maintenance.
Centralized controller up to 16 units including weekly
timer (optional).

 410A fluid.
R
Avoid bacteria and mildew growing by keeping the
heat exchanger dry after cooling operation.
Precise temperature control around dedicated area
by using remote control temperature sensor.
Better cooling and heating affect by extending the air
distribution in the room in a wide angle.
Improve cooling and heating affect by swing the air
up and down automatically.
Adjusting the room temperature along the night
follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air
during start operating in heating.
Digital display on the indoor unit, indicating the
temperature set up or failure code.
Boosting the output capacity and create a rapid
reaction to reach the room temperature set up.
Option to set up the stop and operation.
Indicate the digital failure code on the unit display for
easy detecting and solve problems.
Indication to replace the remote control battery.
Automatic restart the unit in the last operation mode
once resume power supply.
Lock the remote control function to avoid non
required operation.
Minimize the operation without supplying energy
during defrost in heating.
Automatically switch the operation between cooling
to heating to maintain the room set temperature.
Option to control a several units with one main
controller.

ACCESSORIES/OPTIONS
Acc.
RCW-4

Reference
7ACEL1613

Photo

Description

Additional
accessory required

Wired Option to
control a several
units with one main
controller.

Function
- Control up to 16 indoor unit as a group or individualy.
- Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing.
- Indicating failure code.

22

FAF technical data


Indoor Units

AWSI-FAF012-N11 AWSI-FAF018-N11 AWSI-FAF024-N11 AWSI-FAF030-N11 AWSI-FAF036-N11 AWSI-FAF042-N11

Outdoor Units 1~230V - 50 Hz

AWAU-YIF012-H11 AWAU-YIF018-H11 AWAU-YIF024-H11 AWAU-YIF030-H11 AWAU-YIF036-H11

Outdoor Units 3~400V - 50 Hz

Cooling Capacity
Input power

AWAU-YIF036-H13 AWAU-YIF042-H13
kW

3.50

5.00

7.00

8.80

10.00

12.00

kW

1.17

2.03

2.61

3.00

3.60

4.80

2.99

2.46

2.68

2.93

2.77

2.5

kW

3.60

5.70

8.00

9.80

11.00

14.00

kW

1.10

2.07

2.59

2.85

3.3

4.7

3.27

2.75

3.08

3.43

3.33

2.97

EER/Energy Label
Outdoor temperature operating limits C

Heating Capacity
Input power

18/43 Dry bulb

COP/Energy Label
Outdoor temperature operating limits C

Indoor Sound pressure level to 1 m

-7/24 Dry bulb

dB(A) 41/44/46

46/50/54

46/48/50

49/51/52

48/51/54

48/51/54

Sound power level (LS/MS/HS)

m3/h 51/54/56

56/60/64

56/58/60

59/61/62

58/61/64

58/61/64

Airflow (LS/MS/HS)

m /h 550/670/790

970/970/1070

1000/1080/1170

1300/1450/1600

1520/1630/1800

1520/1630/1800

Dehumidification

l/h

1.2

1.9

2.4

2.3

2.9

4.3

Dimensions (WxDxH)

mm

836x695x238

836x695x238

1300x600x188

1420x700x245

1590x695x238

1590x695x238

Weight

kg

27

27

32

50

42

42

7SP012196

7SP012197

7SP012184

7SP012185

7SP012186

7SP012187

56

59

59

60

60

(LS/MS/HS)

Part number

Outdoor Sound pressure level to 1 m

dB(A) 56

Sound power level

dB(A) 66

66

69

69

70

70

Airflow

m3/h 2800

2800

3200

4200

4000

6000

Rotary

Rotary

Rotary

Rotary

Scroll

Scroll

Compressor type
Dimensions (WxDxH)

mm

848x320x540

848x320x540

1018x412x700

980x427x790

1018x412x840

950x412x1250

Weight

kg

32

40

59

70

90

112

7SP061779

7SP061780

7SP061781

7SP061782

7SP061783

Indoor & Outdoor

Indoor & Outdoor

Indoor & Outdoor

Indoor & Outdoor

Indoor & Outdoor

mm2

3x1.0 - 3x1.5

3x1.0 - 3x2.5

3x1.0 - 3x4.0

3x1.0 - 3x6.0

3x1.0 - 3x6.0

Fuse rating am

6 -16

6 - 20

6 - 25

6 - 32

6 - 40

Electrical connections

mm2

2x0.75

2x0.75

2x0.75

2x0.75

2x0.75

1~230V - 50 Hz Part number


3~400V - 50 Hz Part number

7SP061784

Power Power supply side

supply Power cable section


1~230V - 50 Hz

Power Power supply side


supply Power cable section
3~400V - 50 Hz

7SP061785

Indoor & Outdoor

Indoor & Outdoor

mm2

3x1.0 - 5x2.5

3x1.0 - 5x2.5

Fuse rating am

6 - 16

6 - 20

Electrical connections

mm

2x0.75

2x0.75

inches 1/2

1/2

5/8"

5/8"

3/4"

3/4"

Liquid pipe diameter

inches 1/4

1/4

3/8"

3/8"

1/2"

1/2"

Max length

20

20

30

30

50

50

Max height

15

15

15

15

30

30

Pipe Line Suction pipe diameter

AIRWELL SOLUTIONS

23

Light Commercial |

CAF

Cassette 600x600
 assette line available in capacities from 3.5 to
C
5.0 kW.
Cooling & heating operation mode.
Precise temperature control around dedicated
area by using remote control temperature sensor.

RC08A

RCW3

RCW4
(optional)

PRODUCT ADVANTAGES

Main Options

 ired and wireless remote controls provided as


W
standard.
Self diagnostic (error indications) for ease of
maintenance.
230 mm height only.
Centralized controller up to 16 units including weekly
timer (optional).
Fresh air supplied.

 410A fluid.
R
Avoid bacteria and mildew growing by keeping the
heat exchanger dry after cooling operation.
Precise temperature control around dedicated area
by using remote control temperature sensor.
Better cooling and heating affect by extending the air
distribution in the room in a wide angle.
Excellent cooling and heating affect by swing the air
up and down, left and right automatically.
Adjusting the room temperature along the night
follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air
during start operating in heating.
Digital display on the indoor unit, indicating the
temperature set up or failure code.
Boosting the output capacity and create a rapid
reaction to reach the room temperature set up.
Option to set up the stop and operation.
Indicate the digital failure code on the unit display for
easy detecting and solve problems.
Indication to replace the remote control battery.
Automatic restart the unit in the last operation mode
once resume power supply.
Lock the remote control function to avoid non
required operation.
Minimize the operation without supplying energy
during defrost in heating.
Automatically switch the operation between cooling
to heating to maintain the room set temperature.
Condensate drain pump.
Option to control a several units with one main
controller.

ACCESSORIES/OPTIONS
Acc.
RCW-4

Reference
7ACEL1613

Photo

Description

Additional
accessory required

Wired Option to
control a several
units with one main
controller.

Function
- Control up to 16 indoor unit as a group or individualy.
- Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing.
- Indicating failure code.

24

CAF technical data


Indoor Units
Outdoor Units
Cooling

AWAU-YIF012-H11

AWAU-YIF018-H11

kW

3.50

5.00

Input power

kW

1.17

2.00

2.99

2.50

Outdoor temperature operating limits

18/ 43 Dry bulb

Capacity

kW

3.60

5.70

Input power

kW

1.10

1.90

COP/Energy Label

Indoor
unit

3.27
C

-7/ 24 Dry bulb

Sound pressure level to 1 m

dB(A)

43/45/47

43/45/47

Sound power level

dB(A)

53/55/57

53/55/57

Airflow

m /h

620/720/820

620/720/820

Dehumidification

l/h

1.1

1.9

Dimensions (WxDxH)

mm

600x600x230

600x600x230

Weight

kg

20

20

Frame Dimensions 650x650

mm

650x650x50

650x650x50

Weight

kg

2.5

2.5

7SP042208

7SP042209

Part number Frame 650x650

7ACVF0547

7ACVF0547

Sound pressure level to 1 m

dB(A)

56

56

Sound power level

dB(A)

66

66

Airflow

m3/h

2800

2800

Compressor type

Rotary

Rotary

Dimensions (WxDxH)

mm

848x320x540

848x320x540

Weight

kg

40

40

7SP061779

7SP061780

Part number
Power
supply
1~230V - 50 Hz

Pipe Line

3.00

Outdoor temperature operating limits

Part number

Outdoor
unit

AWSI-CAF018-N11

Capacity
EER/Energy Label

Heating

AWSI-CAF012-N11

Power supply side

Indoor & Outdoor

Indoor & Outdoor

Power cable section

mm2

3x1.0 - 3x1.5

3x1.0 - 3x2.5

Fuse rating am

6 -16

6 - 20

Electrical connections

mm

2x0.75

2x0.75

Suction pipe diameter

inches 1/2

1/2

Liquid pipe diameter

inches 1/4

1/4

Max length

20

20

Max height

15

15

AIRWELL SOLUTIONS

25

Light Commercial |

CAF

Cassette 900x900
 assette line available in capacities from 6.8 to
C
12 kW.
Cooling & heating operation mode.
Precise temperature control around dedicated
area by using remote control temperature sensor.
Available in 3PH from 10 kW.

RC08A

RCW3

RCW4
(optional)

PRODUCT ADVANTAGES

Main Options

 ired and wireless remote controls provided as


W
standard.
Self diagnostic (error indications) for ease of
maintenance.
230 mm height only.
Centralized controller up to 16 units including weekly
timer (optional).
Fresh air supplied.

 410A fluid.
R
Avoid bacteria and mildew growing by keeping the
heat exchanger dry after cooling operation.
Precise temperature control around dedicated area
by using remote control temperature sensor.
Better cooling and heating affect by extending the air
distribution in the room in a wide angle.
Excellent cooling and heating affect by swing the air
up and down, left and right automatically.
Adjusting the room temperature along the night
follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air
during start operating in heating.
Digital display on the indoor unit, indicating the
temperature set up or failure code.
Boosting the output capacity and create a rapid
reaction to reach the room temperature set up.
Option to set up the stop and operation.
Indicate the digital failure code on the unit display for
easy detecting and solve problems.
Indication to replace the remote control battery.
Automatic restart the unit in the last operation mode
once resume power supply.
Lock the remote control function to avoid non
required operation.
Minimize the operation without supplying energy
during defrost in heating.
Automatically switch the operation between cooling
to heating to maintain the room set temperature.
Condensate drain pump.
Option to control a several units with one main
controller.

ACCESSORIES/OPTIONS
Acc.
RCW-4

Reference
7ACEL1613

Photo

Description

Additional
accessory required

Wired Option to
control a several
units with one main
controller.

Function
- Control up to 16 indoor unit as a group or individualy.
- Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing.
- Indicating failure code.

26

CAF technical data


Indoor Units

AWSI-CAF024-N11

AWSI-CAF030-N11

AWSI-CAF036-N11

Outdoor Units 1~230V - 50 Hz

AWAU-YIF024-H11

AWAU-YIF030-H11

AWAU-YIF036-H11

Outdoor Units 3~400V - 50 Hz


Cooling

Outdoor
unit

6.80

8.30

10.00

2.62

2.90

3.60

4.80

2.59

2.86

2.77

2.50

7.50

8.80

Outdoor temperature operating limits

Capacity

kW

Input power

kW

18/43 Dry bulb


11.00

14.00

2.50

3.15

3.30

5.00

3.00

2.79

3.33

2.80

Outdoor temperature operating limits

Sound pressure level to 1 m

dB(A) 43/45/47

48/49/51

48/51/53

48/51/53

Sound power level

dB(A) 53/55/57

58/59/61

58/61/63

58/61/63

Airflow

m /h

1000/1080/1180

1170/1270/1400

1500/1570/1660

1500/1570/1650

Dehumidification

l/h

2.35

2.7

2.9

4.3

Dimensions (WxDxH)

mm

840x840x260

840x840x260

840x840x320

840x840x320

Weight

kg

30

27

38

38

Frame Dimensions 950x950

mm

950x950x60

950x950x60

950x950x60

950x950x60

Weight

kg

6.5

6.5

6.5

6.5

-7/24 Dry bulb

7SP042213

Part number

7SP042210

7SP042211

7SP042212

Part number Frame 950x950

7ACVF0548

7ACVF0548

7ACVF0548

7ACVF0548

Sound pressure level to 1 m

dB(A) 59

59

60

60

Sound power level

dB(A) 69

69

70

70

Airflow

m3/h

3200

4200

4000

6000

Rotary

Rotary

Rotary

Scroll

Dimensions (WxDxH)

mm

1018x412x700

980x427x790

1018x412x840

950x412x1250

Weight

kg

59

70

90

112

7SP061781

7SP061782

7SP061783

Indoor & Outdoor

Indoor & Outdoor

Indoor & Outdoor

mm2

3x1.0 - 3x4.0

3x1.0 - 3x6.0

3x1.0 - 3x6.0

Fuse rating am

6 - 25

6 - 32

6 - 40

Electrical connections

mm2

2x0.75

2x0.75

1~230V - 50 Hz

Part number

3~400V - 50 Hz

Part number

Power
supply
1~230V - 50 Hz

Power supply side

Pipe Line

12.00

kW
kW

Compressor type

Power
supply
3~400V - 50 Hz

AWAU-YIF042-H13

Capacity

COP/Energy Label
Indoor
unit

AWAU-YIF036-H13

Input power
EER/Energy Label
Heating

AWSI-CAF042-N11

Power cable section

7SP061784

Power supply side

7SP061785

2x0.75
Indoor & Outdoor

Indoor & Outdoor

Power cable section

mm2

3x1.0 - 5x2.5

3x1.0 - 5x2.5

Fuse rating am

6 - 16

6 - 20

Electrical connections

mm

2x0.75

2x0.75

Suction pipe diameter

inches 5/8"

5/8

3/4

3/4

Liquid pipe diameter

inches 3/8"

3/8

1/2

1/2

Max length

30

30

50

50

Max height

15

15

30

30

AIRWELL SOLUTIONS

27

Light Commercial |

DAF
Ducted

Ducted line available in capacities from 20 up to


39.5 kW.
Cooling & heating operation mode.
Precise temperature control around dedicated
area by using remote control temperature sensor.

RC08A

RCW4
(optional)

RCW3

PRODUCT ADVANTAGES

Main Options

 ired and wireless remote controls provided as


W
standard.
Self diagnostic (error indications) in remote the wired
remote control for ease of maintenance.
Space saving due to low unit height.
Centralized controller up to 16 units including weekly
timer (optional).

 410A fluid.
R
Avoid bacteria and mildew growing by keeping the
heat exchanger dry after cooling operation.
Precise temperature control around dedicated area
by using remote control temperature sensor.
Improve cooling and heating affect by swing the air
up and down automatically.
Adjusting the room temperature along the night
follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air
during start operating in heating.
Boosting the output capacity and create a rapid
reaction to reach the room temperature set up.
Option to set up the stop and operation.
Indicate the digital failure code on the unit display for
easy detecting and solve problems.
Indication to replace the remote control battery.
Automatic restart the unit in the last operation mode
once resume power supply.
Lock the remote control function to avoid non
required operation.
Minimize the operation without supplying energy
during defrost in heating.
Automatically switch the operation between cooling
to heating to maintain the room set temperature.
Option to control a several units with one main
controller.

ACCESSORIES/OPTIONS
Acc.
RCW-4

Reference
7ACEL1613

Photo

Description

Additional
accessory required

Wired Option to
control a several
units with one main
controller.

Function
- Control up to 16 indoor unit as a group or individualy.
- Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing.
- Indicating failure code.

28

DAF technical data


Indoor Units
Outdoor Units 3~400V-50 Hz
Cooling

Capacity

kW

Input power

kW

EER/Energy Label
Annual energy consumption
Heating

kW/h

DAF136

YIF68T

YIF85T

YIF102T

YIF136T

20

24.5

30

39.5

8.4

9.8

11

15.8

2.5/E

2.5/E

2.4/F

2.5/E

4200

4900

5500

7900

kW

22

27.5

33

42

kW

14

3.1/D

3.05/D

3.14/D

3/D

56

54

57

58

Sound pressure level to 1m

dB(A)

Rated current (CO/HP)

15.3/13.2

19.2/17.7

20.7/18

30/26.6

Fan motor speed

rpm

1380

1007

1390

961

External static pressure

Pa

200 (100-250)

110 (30-250)

200 (100-250)

150 (50-300)

Airflow

m3/h

4000

4800

5500

7000

Dimensions (WxHxD)

mm

1150x460x1350

1150x460x1600

990x880x1772

1290x880x1772

Weight

kg

86

150

156

215

7SP032127

7SP032128

7SP032129

7SP032130

Sound pressure level to 1m

dB(A)

65

66

67

69

Airflow

m /h

8000

8000

11000

13000

Dimensions (WxHxD)

mm

1463x799x389

1500x1000x500

1500x1000x500

1700x1100x650

Weight

kg

158

185

216

285

7SP061794

7SP061795

7SP061796

7SP061797

7.5

7.5

7.5

7.5

Code
Pipe Line

DAF102

Capacity

Code
Outdoor
unit

DAF085

Input power
COP/Energy Label
Indoor
unit

DAF068

Length of free charge

g/m

Gas additional charge

g/m

110

54

110

170

Max tubing length

50

50

50

50

Max height difference

30

30

30

30

AIRWELL SOLUTIONS

29

Light Commercial |

DK DN

Air to Air Split system Cooling and heating mode


Cooling Capacity: from 12 to 83 kW
Heating Capacity: from 12.4 to 83.8 kW
Refrigerant: R407C
Sizes: 12
Configuration: Packaged Split system

PRODUCT ADVANTAGES

Main Options

 eather resistant casing with external panels coated


W
with powder-based epoxy paint colour RAL 9001.
Indoor centrifugal fan units for duct network
connection.
High static pressure available.
Multi-position architecture for horizontal or vertical
mounting (acc. to models).
Compact, top discharge outdoor fan units.
Low noise axial fan.
Scroll compressor with crankcase heater.
Electrical, refrigeration and thermal protection
devices.
Phase controller.
External HP and LP pressure taps.
Frame and air filter supplied.

 actory-fitted low ambient temperature control to


F
ensure cooling operation down to -10C outdoor
temperature (All-season).

Main Accessories
 ynthetic air filter.
S
Electric heater.
Programmable controller RCW2 to control up to 15
units with independent set points and programming.

Operating limit for Standard unit


Cooling mode
Minimum indoor air temperature

21C DB/ 15C WB

Maximum indoor air temperature

32C DB/ 23C WB

Minimum outdoor air temperature / with all-season kit

15C DB/ -10C

Maximum outdoor air temperature

46C DB

Heating mode
Maximum indoor air temperature

27C DB

Minimum outdoor air temperature

-10C

Maximum outdoor air temperature

24C DB / 18C WB

30

AIRWELL SOLUTIONS

DK DN 125-155-185 technical data


INDOOR UNIT
OUTDOOR UNIT

DK 125

DK-V 125

DK 155

DK-V 155

DK 185

DN 125

DN 155

DN 155

DN 185

DN 125RC

DN 155RC

DN 155RC

DN 185RC

Code 7SP051153

7SP051152

7SP051154

7SP051151

7SP051069

Code -

Cool only DN 125


Reversible DN 125RC

Product codes:
Small ventilation

Indoor Unit

High ventilation

Outdoor Unit
- Cool only

standard

Code 7SP111061

7SP111061

7SP111054

7SP111054

7SP111055

With all-season control

Code 7SP111081

7SP111081

7SP111082

7SP111082

7SP111080

Outdoor Unit
- Reversible

standard

Code 7SP111062

7SP111062

7SP111056

7SP111056

7SP111057

With all-season control

Code 7SP111079

7SP111079

7SP111083

7SP111083

7SP111084

CAPACITIES
Cooling

Cooling capacity

kW

12.0

12.0

14.5

14.5

17.5

Power input

kW

4.9

4.9

5.8

5.8

6.9

2.4

2.4

2.5

2.5

2.5

EER
Heating

Heating capacity

kW

12.4

12.4

15.7

15.7

18

Power input

kW

4.8

4.8

5.8

5.8

6.4

2.6

2.7

2.7

2.8

2.7

COP
INDOOR UNIT
VENTILATION
SOUND LEVELS
DIMENSIONS
WEIGHT

Available static pressure

Pa

160

180

130

110

200

Nominal Airflow

m/h

2100

2100

2850

2850

3500

Airflow range (min/max)

m/h

1600/2400

1600/2400

2300/3100

2300/3100

2800/3900

Sound power level

dB(A)

72

69

73

72

75

LxWxH

mm

1150x745x340

1050x972x350

1350x745x340

1254x972x350

1350x745x400

Mounting

H/V

H/V

H/V

Unit weight

kg

58

69

65

77

98

OUTDOOR UNIT
VENTILATION

Number of fan
Nominal Airflow

m/h

5400

5400

9000

9000

9000

SOUND LEVELS

Sound power level

dB(A)

82

82

82

82

79

DIMENSIONS

LxWxH

mm

746x746x 909

746x746x 909

900x800x1060

900x800x1060

900x800x1060

WEIGHT

Unit weight

kg

140

140

150

150

164

POWER SUPPLY Power supply

400V/3P/50 Hz

Power supply side


PIPE LINE

Outdoor

Suction pipe diameter < 20m

inches

3/4"

3/4"

7/8"

7/8"

7/8"

Suction pipe diameter > 20m

inches

3/4"

3/4"

3/4"

3/4"

3/4"

Liquid pipe diameter < 20m

inches

1/2"

1/2"

1/2"

1/2"

5/8"

Liquid pipe diameter > 20m

inches

1/2"

1/2"

1/2"

1/2"

5/8"

Max lenght

50

50

50

50

50

Max height
ACCESSORIES
Electric heater

50

50

50

50

50

kW

10.5

12

Code

7ACEL1093

7ACEL1208

7ACEL1096

7ACEL1209

7ACEL1184

kW

8.1

8.1

Code
Remote control RCW2

Code

Air filter

Code

7ACEL1094

7ACEL1097
7ACEL1212

7ACVF0077

7ACVF0077

31

7ACVF0078

7ACVF0078

Light Commercial |
DK DN 205-255-305-405 technical data
INDOOR UNIT
OUTDOOR UNIT

DK 205
Cool only DN 205

DK 255

DK 305

DK 405 M

DK 405

DN 255

DN 305

DN 405 M

DN 405

DN 255RC

DN 305RC

DN 405MRC

DN 405RC

Code 7SP051141

7SP051142

7SP051143

7SP051155

7SP051144

Code -

7SP051147

7SP051156

7SP051148

Reversible DN 205RC

Product codes:
Small ventilation

Indoor Unit

High ventilation

Outdoor Unit
- Cool only

standard

Code 7SP112013

7SP112014

7SP112015

7SP112131

7SP112016

With all-season control

Code 7SP112082

7SP112083

7SP112084

7SP112131

7SP112085

Outdoor Unit
- Reversible

standard

Code 7SP112019

7SP112020

7SP112021

7SP112132

7SP112022

With all-season control

Code 7SP112088

7SP112089

7SP112090

Included

7SP112091

21.0

28.5

36.0

37.5

CAPACITIES
Cooling

Cooling capacity

kW

Power input

kW

EER
Heating

19.1
7.3

8.6

11.5

13.9

14.4

2.6

2.4

2.5

2.6

2.6

Heating capacity

kW

18.3

21

27.3

36.0

36.5

Power input

kW

6.7

9.3

13.3

11.9

2.9

2.7

2.9

210

210

190

180

180

COP
INDOOR UNIT
Available static pressure
VENTILATION
SOUND LEVELS
DIMENSIONS
WEIGHT

Pa

Nominal Airflow

m/h

4500

4680

5760

7560

7560

Airflow range (min/max)

m/h

3600/5000

3800/5100

4600/6300

6000/8200

6000/8200

Sound power level

dB(A)

84

84

78

83

83

LxWxH

mm

1352x1060x400 1692x1060x400 1690x1005x676 1690x1005x676 1690x1078x676

Mounting

H/V

Unit weight

kg

98

100

150

160

160

OUTDOOR UNIT
VENTILATION

Number of fan
Nominal Airflow

m/h

9000

9000

9000

16000

2x9000

SOUND LEVELS

Sound power level

dB(A)

78

78

86

83

87

DIMENSIONS

LxWxH

mm

900x800x1060

900x800x1060

1003xx1003x1094 1004x1004x1257

1708x1123x972

WEIGHT

Unit weight

kg

164

164

187

247

317

1-3/8"

7/8"

POWER SUPPLY Power supply

400V/3P/50 Hz

Power supply side


PIPE LINE

Suction pipe diameter < 20m

Outdoor
in

1-1/8"

1-1/8"

7/8"

Suction pipe diameter > 20m

in

1-1/8"

1-1/8"

1-1/8"

1-3/8"

7/8"

Liquid pipe diameter < 20m

in

1/2"

1/2"

5/8"

5/8"

1/2"

Liquid pipe diameter > 20m

in

5/8"

5/8"

5/8"

5/8"

5/8"

Max lenght

30

30

30

30

30

Max height

15

15

15

10

15

kW

12

18

18

21

21

Code

7ACEL1186

7ACEL1189

7ACEL1176

7ACEL1177

7ACEL1177

kW

7ACVF0124

7ACVF0124

7ACVF0125

7ACVF0125

7ACVF0125

ACCESSORIES
Electric heater

Code
Remote control RCW2

Code

Air filter

Code

7ACEL1212

32

DK DN 505-605-755-905 technical data


INDOOR UNIT
OUTDOOR UNIT

DK 505

DK 605

DK 755

DK 905

Cool only DN 505

DN 605

DN 755

DN 905

DN 605RC

DN 75RC5RC

DN 905RC

Reversible DN 5RC05RC

Product codes:
Indoor Unit

Small ventilation

Code 7SP051145

7SP051146

7SP051122

7SP051123

High ventilation

Code 7SP051149

7SP051150

Outdoor Unit
- Cool only

standard

Code 7SP112017

7SP112018

7SP112137

7SP112146

With all-season control

Code 7SP112086

7SP112087

Included

Included

Outdoor Unit
- Reversible

standard

Code 7SP112023

7SP112024

7SP112138

7SP112147

With all-season control

Code 7SP112092

7SP112093

Included

Included

56.0

69.1

83.0

CAPACITIES
Cooling

Cooling capacity

kW

Power input

kW

EER
Heating

44.0
16.7

22.5

26.9

33.0

2.6

2.5

2.6

2.5

Heating capacity

kW

42.0

57.5

71.0

83.8

Power input

kW

14.4

22.9

26.4

32.4

2.5

2.7

2.6

2.5

520

320

330

460

COP
INDOOR UNIT
Available static pressure
VENTILATION
SOUND LEVELS
DIMENSIONS
WEIGHT

Pa

Nominal Airflow

m/h

9360

9720

12000

14300

Airflow range (min/max)

m/h

7500 / 10300

7780 / 11000

9600 / 13200

11440 / 15730

Sound power level

dB(A)

84

85

87

87

LxWxH

mm

2100x1078x703

2100x1078x703

2208x949x795

2208x949x945

Mounting

H/V

Unit weight

kg

205

209

266

282

OUTDOOR UNIT
VENTILATION

Number of fan
Nominal Airflow

m/h

2x9000

2x9000

2x16000

2x16000

SOUND LEVELS

Sound power level

dB(A)

86

86

87

87

DIMENSIONS

LxWxH

mm

1708x1123x1171

1708x1123x1171

2213x1345x1309

2213x1345x1459

WEIGHT

Unit weight

kg

378

405

559

592

POWER SUPPLY Power supply

400V/3P/50 Hz

Power supply side


PIPE LINE

Suction pipe diameter < 20m

Outdoor
in

7/8"

1-1/8"

1-1/8"

1-3/8"

Suction pipe diameter > 20m

in

7/8"

1-1/8"

1-3/8"

1-3/8"

Liquid pipe diameter < 20m

in

1/2"

1/2"

5/8"

5/8"

Liquid pipe diameter > 20m

in

5/8"

5/8"

5/8"

5/8"

Max lenght

30

30

30

30

Max height

15

15

15

15

kW

30

30

30

30

Code

7ACEL1178

7ACEL1178

7ACEL1340

7ACEL1340

ACCESSORIES
Electric heater

kW

Code

7ACVF0126

7ACVF0126

Remote control RCW2

Code

Air filter

Code

7ACEL1212

33

Light Commercial |

X AR

Vertical Air Cabinet - cooling only


Cooling Capacity: from 9.7 to 55 kW
Refrigerant: R407C
Sizes: 6
Configuration: Split system

PRODUCT ADVANTAGES

Main Accessories

 asy installation and maintenance.


E
Split system with outdoor condenser fan unit.
Treated air distribution to premise by plenum or duct
network.
Adjustable available static pressure.
Temperature control by thermostat.
Electrical, refrigeration and thermal protection
devices.

 oom thermostat.
R
Electric heater.
Hot water heating coil.
All season system (Cooling mode operation down
to outdoor temperature of -10C).
Remote fault reporting.
Plenum.
Duct flange.
Valves.
Pipe link.

Operating limit for Standard unit


Indoor unit
Minimum air temperature (room / intake / around unit)

21C DB/ 15C WB

Maximum air temperature (room / intake / around unit)

32C DB/ 23C WB

Outdoor unit
Minimum air temperature / with all-season kit

15C DB/ -10C

Maximum air temperature

46C DB

34

X AR technical data

Cooling
CAPACITIES

INDOOR UNIT
OUTDOOR UNIT
Product codes:
Indoor unit
Code
Outdoor unit
Code
Cooling capacity
kW
Power input
kW
EER
Cooling circuit

X 1100 AR
UC 33 A

X 1900 AR
UC 53 A

X 2450 AR
UC 73 A

X 3250 AR
UC 103 A

X 4650 AR
UC 73 A

X 6450 AR
UC103 A

7XU022082
7XU031025
9.7
4.6
2.13
1

7XU022077
7XU031026
16.2
6.8
2.38
1

7XU022078
7XU031027
19.8
8.9
2.22
1

7XU022079
7XU031028
29.0
12.6
2.3
1

7XU022080
2 x 7XU031027
38.9
16.9
2.3
2

7XU022081
2 x 7XU031028
55.0
24.0
2.3
2

Pa
m/h
m/h
dB(A)
mm
mm
kg

200
2000
1500/2500
66
890x430x1540
220
136

300
3200
2500/3800
68
1000x500x1735
260
182

200
4500
3600/5400
75
1300x600x1840
350
265

200
5800
4600/7000
81
1530x600x1840
350
350

250
9000
7200/10800
77
1715x790x1970
400
525

290
12000
9500/14500
85
1980x790x1970
400
600

m/h
dB(A)
mm
kg

1
220
54
885x825x831
59

1
260
58
885x825x831
68

2
400
64
1141x885x831
93

2
400
76
1546x885x893
130

in
in
m

1/2"
3/8"
45

1/2"
3/8"
45

1
1
350
350
61
73
1141x885x831 1546x885x893
93
130
400V/3P/50 Hz
Indoor
5/8"
3/4"
1/2"
5/8"
45
45

5/8"
1/2"
45

3/4"
5/8"
45

INDOOR UNIT
Available static pressure
Nominal Airflow
Airflow range (min/max)
SOUND LEVELS Sound power level
LxWxH
DIMENSIONS
Plenum height
WEIGHT
Unit weight
OUTDOOR UNIT
Condenser unit
VENTILATION
Nominal Airflow
SOUND LEVELS Sound power level
DIMENSIONS
LxWxH
WEIGHT
Unit weight
Power supply
POWER
SUPPLY
Power supply side
Suction
pipe diameter
PIPE LINE
Liquid pipe diameter
Max lenght
VENTILATION

ACCESSORIES
Set of female valves Code

7ACFH0054

7ACFH0055

7ACFH0056

7ACFH0061

7ACFH0057

7ACFH0060

Pipe link Code


kW
Electric heater
Code
kW
Hot water coil
Code
ON/OFF switch and room thermostat Code
"High ventilation" Code
"All season" system Code
Remote fault reporting Code
Air distribution duct frame Code
Total rear air intake duct frame Code
Front air distribution plenum Code
Fresh air supplied Code

7ACFH0210

7ACFH0211

7ACFH0212

7ACFH0213

7ACFH0214

7ACFH0215

9
7ACEL0042
15.5
7ACFH0062
7ACEL0041
7ACVF0023
7ACFH0069

12
7ACEL0043
29.7
7ACFH0063
7ACEL0041
7ACVF0024
7ACFH0070

7ACVF0101
7ACVF0041
7ACVF0105
7ACVF0047

7ACVF0102
7ACVF0104
7ACVF0106
7ACVF0047

18
7ACEL0057
38.5
7ACFH0064
7ACEL0032
7ACFH0104
7ACEL0072
7ACVF0050
7ACVF0043
7ACVF0108
-

22.5
7ACEL0058
50
7ACFH0118
7ACEL0032
7ACFH0072
7ACEL0072
7ACVF0051
7ACVF0044
7ACVF0109
-

37.5
7ACEL0116
77
7ACFH0180
7ACEL0032
7ACFH0071
7ACEL0071
7ACVF0052
7ACVF0045
7ACVF0110
-

45
7ACEL0119
94
7ACFH0170
7ACEL0032
7ACFH0146
7ACEL0071
7ACVF0052
7ACVF0046
7ACVF0111
-

AIRWELL SOLUTIONS

35

Light Commercial |

X AO

Vertical Water Cabinet cooling only


Cooling Capacity: from 8 to 45.7 kW
Refrigerant: R407C
Sizes: 6
Configuration: Monobloc system

PRODUCT ADVANTAGES

Main Accessories

 asy installation and maintenance.


E
Monobloc system.
Public or recycled water operation.
Treated air distribution to premise by plenum or duct
network.
Adjustable available static pressure.
Temperature control by thermostat.
Electrical, refrigeration and thermal protection
devices.

 oom thermostat.
R
Electric heater.
Hot water heating coil.
Remote fault reporting.
Plenum.
Duct flange.

Operating limit for Standard unit


Minimum air temperature

21C DB/ 15C WB

Maximum air temperature

32C DB/ 23C WB

Minimum water temperature

+10C

Maximum water temperature

+30C

36

X AO technical data
230V/1P/50 Hz
400V/3P/50 Hz

X AO Model
Product codes:
Code
with valve Code
without valve Code

CX 25

X 1100 AO

X 1900 AO

X 2450 AO

X 3250 AO

X 4650 AO

7XU012032
7XU012033
-

7XU012025
-

7XU012028
-

7XU012029
7XU012047

7XU012030
7XU012048

7XU012031
7XU012064

kW
kW

8.0
2.6
3.14
1

11.7
3.8
3.08
1

18.0
5.8
3.1
1

23.0
7.1
3.24
1

32.4
9.8
3.31
1

45.7
13.9
3.29
2

Pa
m/h
m/h

80
1500
1160/1750

200
2000
1500/2500

250
3200
2500/3800

200
4500
3600/5400

250
5800
4600/7000

250
9000
7200/10800

m3/h
kPa
m3/h
kPa

0.34
20
1.17
21

0.58
22
2.1
50

0.92
18
3.4
70

1.45
42
4.3
60

2
40
5.8
40

2.8
18
8.3
56

dB(A)

64

65

67

74

80

76

CAPACITIES
Cooling capacity
Power input
Cooling
EER
Cooling circuit
VENTILATION
Available static pressure
Nominal Airflow
Airflow range (min/max)
HYDRAULIC
Water flow
Wasted water
pressure drop
Recycled Water flow
water pressure drop
SOUND LEVELS
Sound power level
POWER SUPPLY

230V/1P/50 Hz
400V/3P/50 Hz

Power supply

400V/3P/50 Hz

DIMENSIONS
LxWxH
Plenum height

mm
mm

800x407x 1280
300

890x430x1540
220

1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970


260
350
350
400

Unit weight

kg

125

151

199

305

380

565

5.49
7ACEL0017
7ACEL0018
7ACEL0030
7ACVF0025
7ACVF0027

9
7ACEL0042
15.5
7ACFH0062
7ACEL0041
7ACVF0023
7ACVF0029

12
7ACEL0043
29.7
7ACFH0063
7ACEL0041
7ACVF0024
included

7ACVF0112
-

7ACVF0101
7ACVF0041
7ACVF0105
7ACVF0047

7ACVF0102
7ACVF0104
7ACVF0106
7ACVF0047

18
7ACEL0057
38.5
7ACFH0064
7ACEL0032
7ACEL0072
7ACVF0050
7ACVF0108
-

22.5
7ACEL0058
50
7ACFH0118
7ACEL0032
7ACEL0072
7ACVF0051
7ACVF0109
-

37.5
7ACEL0116
77
7ACFH0180
7ACEL0032
7ACEL0071
7ACVF0052
7ACVF0110
-

WEIGHT
ACCESSORIES
Electric heater kW
230V/1P/50 Hz code
400V/3P/50 Hz Code
kW
Hot water coil
Code
ON/OFF switch and room thermostat Code
"High ventilation" Code
Sum heating resistance Code
Remote fault reporting Code
Air distribution duct frame Code
Total rear air intake duct frame Code
Front air distribution plenum Code
Fresh air supplied Code

AIRWELL SOLUTIONS

37

Light Commercial |

HAN

Rooftop unit - cooling and heating


Cooling Capacity: from 9.8 to 31kW
Heating Capacity: from 9.6 to 30.5 kW
Refrigerant: R410A
Sizes: 7
Configuration: Compact monobloc system

PRODUCT ADVANTAGES

Main Options

 eather resistant casing with external panels and


W
drain pan coated with powder-based epoxy paint
colour RAL 9001.
Base rail with forklift slots to facilitate transportation
and handling.
Technical compartment independent from airstreams
allowing service works to be performed without
disturbing the unit operation.
High EER and environmentally friendly refrigerant
R410A with zero ODP (Ozone Depleting Potential).
High efficiency scroll compressor with crankcase
heater.
Condenser coils with hydrophilic coated fins to
improve removal of water droplets during defrost
cycles.
Standard microprocessor-based control by CAC
controller.

 actory-fitted low ambient temperature control to


F
ensure cooling operation down to -10C outdoor
temperature (All-season).

Main Accessories
 ynthetic air filter.
S
Electric heater.
Programmable controller RCW2 to control up to 15
units with independent set points and programming.

Operating limit for Standard unit


Cooling mode
Minimum indoor air temperature

21C DB/ 15C WB

Maximum indoor air temperature

32C DB/ 23C WB

Minimum outdoor air temperature / with all-season kit

15C DB/ -10C

Maximum outdoor air temperature

50C DB

Heating mode
Maximum indoor air temperature

27C DB

Minimum outdoor air temperature

-10C

Maximum outdoor air temperature

24C (16C for HAN 25)

38

HAN technical data


HAN Model HAN 10

HAN 13

HAN 15

HAN 17

HAN 19

HAN 25

HAN 31

Product codes:
standard Code

7HL023001

7HL023002

7HL023003

7HL023004

7HL023005

7HL023006

7HL023007

with all season control Code

7HL023008

7HL023009

7HL023010

7HL023011

7HL023012

7HL023013

7HL023014

9.8

13.0

14.5

16.8

18.9

25.4

31.0

CAPACITIES
Cooling capacity
Cooling Power input

kW
kW

EER
Heating

3.7

4.5

4.9

6.0

6.5

8.3

10.0

2.64

2.88

2.95

2.8

2.9

2.95

3.1

Heating capacity

kW

9.6

12.1

14.2

15.8

19.0

24.2

30.5

Power input

kW

3.0

4.3

4.5

5.7

6.0

8.8

9.5

3.2

2.8

3.1

2.7

3.1

2.75

3.2

COP
VENTILATION

Airflow

Available static pressure

Pa

90

100

170

160

210

240

250

Indoor fan

m/h

1930

2640

2940

3190

3860

4780

5530

Outdoor fan

m/h

5200

9000

9000

9000

9000

12000

12000

SOUND LEVELS
dB(A)

79.7

79.3

79.3

79.3

83.1

84.9

86.4

Sound power level (Outdoor) dB(A)

Sound power level (Indoor)

76.1

75.0

75.0

75.0

72.7

78.2

82.7

POWER SUPPLY
Power supply

400V/3P/50 Hz

DIMENSIONS
LxWxH

mm

1115x1150x750 1320x1345x905 1320x1345x905 1320x1345x905 1320x1345x905 1420x1445x1320 1420x1445x1320

Unit weight

kg

165

WEIGHT
219

223

223

243

320

343

ACCESSORIES
Air filter
Electric heater
Remote control RCW2

Code

7ACVF0145

7ACVF0481

7ACVF0481

7ACVF0481

7ACVF0481

7ACVF0482

7ACVF0482

kW

12

12

12

12

Code

7ACEL1216

7ACEL1217

7ACEL1217

7ACEL1219

7ACEL1219

7ACEL1219

7ACEL1219

Code

7ACEL1212

7ACEL1212

7ACEL1212

7ACEL1212

7ACEL1212

7ACEL1212

7ACEL1212

AIRWELL SOLUTIONS

39

LCAC EXP GB 0412 - Specifications subject to change without notice. Pictures non contractual. Printed in UE.

Airwell France SAS


1 bis avenue du 8 mai 1945
78280 Guyancourt
France
Tel. +33 (0)1 39 44 78 00
Fax +33 (0)1 39 44 00 14
www.airwell.com