Vous êtes sur la page 1sur 2

Form nr F-7.5.

1-05

Appendix nr 5 for PR-7.5.1-02

TEST
MEXICO DF

Alumno
Place / Date: Mxico DF, 31/jan/2015
1.) Does Structural Cabling System FIBRAIN DATA meet all international standards (ANSI EIA/TIA
568, ISO 11801, CENELEC 50173)?:
o
YES
o
NO
2.) What type of cable is recommended for network connections:
o Coaxial Cable
o Twisted Pair: UTP or FTP
o Phone Cable
3.) The maximum length for network cable in horizontal cabling installations, between Floor
Distribution Point and Technical Outlet (without patch cords) is:
o 90m
o 120m
o 100m
4.) The difference between cable FTP and UTP is:
o FTP cable is cheaper, and easier to make connections
o FTP has a metallic screen to protect from electromagnetic interference
o Using FTP cable makes possible installations in excess of 100m for horizontal networks
5.) Fiber optic cables:
o Make possible longer distance connections compared to copper cables
o Multimode fiber allows longer distance connections compared to single mode fiber
o Are not so resistant to electromagnetic interferences as copper cables
6.) The most used technology in structural cabling is:
o Token Ring
o Ethernet
o Thinknet
7.)

How many pairs contains the copper twisted pairs network cable:
o 2 pairs
o 4 pairs
o 8 pairs

8.) What is the difference between NEXT value in standards ISO and TIA/EIA for Cat 6A components
for maximum allowed frequencies.
o 2dB
o 3dB
o 4dB
9.) How many pairs are used for Ethernet technology in Cat.6A cabling:
o 1 pair
o 2 pairs
o 4 pairs
10.) What means LSZH (LSOH):
o Flame retardant cable, no contains halogens
o Special cable for multimode transmission
o Low Signal Loose Cables
11.) Parameter ANEXT is obligatory in case of:
o Cat. 6 FTP cabling

F-7.5.1-05/I

1/2

Form nr F-7.5.1-05
o
o

Appendix nr 5 for PR-7.5.1-02

Cat. 6A unshielded cabling


Fiber optic cabling

12.) In a system with multiple category components:


o The system shall be rated as that of the highest performing component
o The system shall be rated as that of the lowest performing component
o Is not possible to make a system with multiple category components
13.) Which colour is not recognized by 568 TIA/EIA standard for 4-pairs twisted cable
o blue
o black
o orange
14.) Which organizations make standards for structural cabling:
o Mexican Government
o UN
o CENELEC, EIA/TIA, ISO/IEC
15.) What is the core diameter of multimode fibers:
o 62,5um or 50um
o 9um
o 125um
16.) The basic principle of how fiber optic works is based on:
o Total internal reflection phenomena
o Dispersion phenomena
o Matching the same refraction index for fiber core and fiber coat
17.) Which fiber type is a singlemode:
o OM4
o OM2+
o OS1
18.) How we call signal power losses inside a twisted pairs cable:
o Dispersion
o Attenuation
o Impedance
19.) The NEXT parameter:
o Link is more resistant for interferences if the NEXT absolute value is bigger
o Link is more resistant for interferences if the NEXT absolute value is lower
o Does not depend on frequency of a transmitted signal
20.) Which parameter characterizes the signal speed differences between the pairs of a cable
o Delay skew
o RL
o ACR
21.) What is the permanent link:
o Structural cabling between a horizontal cross connect and a work area outlet
o Distance from a main cross connect to a work area outlet
o Maximum of 15 meters of horizontal cable between a consolidation point and a horizontal cross
connect
22.) How many transition or consolidation points are allowed between a horizontal cross connect and
a work area outlet:
o No one
o No limits
o Only one
23.) Receiving the FIBRAIN DATA Warranty Certificate for installed cabling requires:
o Complete measurement results with technical documentation and photos
o Only measurement results
o It is enough to indicate the installation place by fax or e-mail.

F-7.5.1-05/I

2/2

Vous aimerez peut-être aussi