A61
FEMALE x FEMALE
CERTIFICATIONS
Standard equipment:
Female NPT inlet and outlet, forged
brass body, brass finish ball
with teflon seats.
LISTED 36Y7
FM approved at 300 psi *
UL listed
a
c
C
H
PORT
SPECIFY THREAD
A61
c (plug)
PORT
1(3/8-2.8)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1(7/16- 4.2)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1 (1/2-5.6) *
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1(17/32- 8) *
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4 (3/8-2.8)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4 (7/16-4.2)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4 (1/2-5.6) *
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4(17/32- 8) *
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4 (5/8-11.2)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
1-1/4 (3/4-14)*
1/4
1-1/16
5-1/32
2-43/64
5-11/32
4-27/64
1-57/64
GROOVE X GROOVE
CERTIFICATIONS
Standard equipment:
GROOVE inlet and outlet, forged
brass body, brass finish ball with
teflon seats.
a
c
C
H
PORT
SPECIFY THREAD
42
PORT
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
1-1/4 (17/32 - 8)
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
1/4
1-1/16
6-13/32
2-43/64
5-11/32
4-27/64 1-1/4groove
Products
Test and drain valve
Female x Female
1" (orifice 1/2")
1 1/4"(orifice 1/2")
1" (orifice 17/32")
1 1/4" (orifice 17/32")
Thread
A61Y005
A61Y006
A61Y015
A61Y016
Dimensions
PORT
1 7/64" 5 1/32"
1 7/64" 5 1/32"
1 7/64" 5 1/32"
1 1/4" (orifice
17/32")
1 7/64" 5 1/32"
B
2
45/64"
2
45/64"
2
45/64"
2
45/64"
C
5
11/32"
5
11/32"
5
11/32"
511/32"
Wet Systems
A test connection not less than 1 in. (25 mm) in
diameter, terminating a smooth bore corrosion
resistant orifice, given a flow equivalent to one
sprinkler of a type having the smallest orifice
installed on the particular system, shall be
provided to test each waterflow alarm device for
each system. The test connection valve shall be
readily accessible. The discharge shall be to the
outside, to a drain connection capable of
accepting full flow under system pressure or to
another location where water damage will not
result.
Drainage
All sprinkler pipes and fittings shall be so
installed that the system may be drained
Giacomini Test and Drain valve merges in one
valve the above two functions of testing and
draining the system.
Connections to the branch line (a and b) 1" and
1 1/4"
Orifice 1/2" or 5/8" size
Pressure
1 de 1
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpag...
VEHZ.EX4430
Drain Fittings, Special Type
Page Bottom
EX4430
Notice of Disclaimer
Page Top
Copyright 2010 Underwriters Laboratories Inc.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data
(or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must
appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright
2010 Underwriters Laboratories Inc."
Model A61
Model Designation
Nominal
K-factor(s)
Rated working
pressure,
psi (kPa)
Remarks
A61
300 (2070)
A61
1 14
300 (2070)
a, b
A61
300 (2070)
a, b
Remarks:
a. Devices supplied with female NPT threaded end connections.
b. Devices supplied with grooved end connections.
1 of 1