Vous êtes sur la page 1sur 32

Variable Displacement Pump (A)A10V

Series-31

Industrial & Mobile, Single & Thru Shaft Models, A10V / AA10V
18, 28, 45, 71, 100 & 140 Frame Sizes Available
Same Day Shipment of Units or Parts Orders
DR, DRG, DFR, DFR1, DFLR Controls
SAE & Metric Units

www.FluiDyneFP.com I sales@fluidynefp.com I 586-296-7200

Index
Variable Displacement Pump (A)A10V, Series 31. . .. . .. . .. . .. . .. . .. . .. . .. . .. 4

Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Ordering Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Fluid Operational Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Noise Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DR Pressure Control Data, Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 10

DRG Pressure Control Data / Remote Control / Dimensions. . .. . .. . .. . .. . .. . .. . .. . .. . . 12

DFR/DFR1 Pressure / Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

DFLR Pressure / Flow / Power Control / Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 15


Mounting Dimensions, Size 18, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 17

Mounting Dimensions, Size 28, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18


Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

(A)A10V28 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 19

Mounting Dimensions, Size 45, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20


Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

(A)A10V45 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 21

Mounting Dimensions, Size 71, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Service Ports on Side and Rear; Non Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

(A)A10V71 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 23

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Mounting Dimensions, Size 100, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24


Service Ports on Side & Rear; Non Through Drive. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 24

(A)A10V100 Shaft, Metric Mount, and Port Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Mounting Dimensions, Size 140, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26


Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 26

Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Overview of Through Drive Mounting Options / Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Shaft Torque Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Pump Installation Notes . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 31

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

Variable Displacement Pump (A)A10V, Series 31


Features
Axial piston pump A10V in swashplate design is used for
hydrostatic transmissions in open loop circuits. Flow is
proportional to drive speed and displacement. By adjusting
the position of the swashplate it is possible to smoothly vary
the flow.

Swash
plate

Cylinder
block

Variable
piston

Piston

Housing

Valve
plate

DFR
control valve

End cover

Shaft

Returning piston

Flange connections to SAE-UNC or Isometric


2 case drain ports
High permissible speeds
Good suction characteristics
Low noise level
High power/weight ratio
Variable Displacement Pump (A)A10V, Series 31

Long service life


Quick response time
Axial and radial loading of drive shaft possible
Wide range of controls
Through drive option for multi-circuit system

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31


Technical Data
1. Input operating pressure range

Absolute pressure at port S (A)

P min........................................0.8bar (12 psi)

abs

max.......................................30bar (435 psi)

abs

2. Output operating pressure range



Pressure at port B

Nominal pressure PN....................280bar (4000 psi)

Peak pressure Pmax...............350bar (5100 psi)


Pressure data to DIN24312

3. Case drain pressure



Maximum pressure of leakage fluid ( at ports L, L1 ). Maximum 7 psi ( 0.5 bar ) higher than input pressure at port

S, but not higher than 30 psi ( 2 bar ) absolute.
4. Direction of flow : ( S to B )
5. Table of values (theoretical values, without considering
Size cm3/rev

mh and

v ; values rounded)

18

28

45

71

100

140

18 (1.10)

28 (1.71)

45 (2.75)

71 (4.33)

100 (6.1)

140 (8.54)

3300

3000

2600

2200

2000

1800

59.4 (15.7)

84 (22)

117 (31)

156 (41)

200 (53)

252 (67)

28 (36.6)

39 (51)

55 (72)

73 (96)

93 (124)

118 (156)

Displacement

Vg max

cm /rev (in /rev)

Max. Speed

No max

rpm

Max. Flow

Oo max

L / min (gpm)

Max. Power

Po max

kW (HP)

Max. Torque
@Vg max, No max

Tmax

Nm (ft - lb)

80 (58)

125 (91)

200 (146)

316 (230)w

445 (324)

623 (453)

Kg (lbs)

12 (27)

15 (33)

21 (46)

33 (73)

45 (99)

60 (132)

Weight (without fluid)

Notes: Values shown are valid for an absolute pressure of 1 bar at suction port. If the flow is
reduced or if the inlet pressure is increased the speed may be increased.

6. Determination of size
Flow

qv =

Torque T =

Power

www.FluiDyneFP.com

P=

Vg n v
231
Vg p
24 mh
qv p
1714 t

[gpm]

[lb-ft]

[HP]

(
(
(

qv =

T=

P=

Vg n v

Vg p
20 mh
qv p
600 t

)
)
)

[L/min]

1000

[Nm]

[kW]

V g = Displacement per revolution in in3 (cm 3 )


p = Differential pressure in psi (bar)
n

= Speed in rpm (min 1 )

v = Volumetric efficiency
mh = Mechanical-hydraulic efficiency
t = Total efficiency

Variable Displacement Pump (A)A10V, Series 31

Variable Displacement Pump (A)A10V, Series 31


Ordering Code
(A)A10V(S)

Axial Piston Unit


Swash plate variable pump

71

DR

31

A10V

Swash plate variable pump for industrial

A10VS

Mode of Operation
Pump, open circuit

Size
Displacement Vgmax

18
(1.10)

28
(1.71)

45
(2.75)

71
(4.33)

100
(6.10)

140
(8.54)

Pressure control
Pressure remote control

DR
DRG

Pressure and flow control


Pressure & flow (w/ X port blocked)

DFR
DFR1

Pressure,Flow & Power control

DFLR

cm3//rev
(in3//rev)

Control Devices

Series
Series

31

Direction of Rotation
Viewed from shaft end

clockwise

counter-clockwise

Seals
Buna-N (NBR per DIN IS0 1629) ;

FPM (flurocarbon)

18

28

45

71

100

140

SAE- splined shaft, reinforced (U-type shaft)

l
l
l
l

l
l
l

l
l
l
l

l
l
l
l

l
l
l

l
-

SAE- keyed shaft

Parallel with key DIN 6885

Shaft End
SAE-splined shaft
SAE-splined shaft, reinforced (higher thru drive torque)
SAE splined shaft, smaller size (not for pumps with thru drive)

Variable Displacement Pump (A)A10V, Series 31

S
R
U

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

62

N00
Through drives

18

Without through drive (Non-Thru Drive)

28

45

71 100 140

N00

O
l
l
-

l
l
l
l
l
-

l
l
l
l
l
l
l
-

l
l
l
l
l
l
l
l
l
-

l
l
l
l
l
l
l
l
l
l
l
-

l
l
l
l
l
l
l
l
l
l
l
l
l

K401)

With through drive to accept an axial piston pump or a gear pump


Mounting flange SAEJ744

hub

82-2 (A)

3/4 keyed (A-B)

axial

A10V18 (K)

101-2 (B)

7/8 keyed (B)

axial

A10V28 (K)

101-2 (B-B)

1 keyed (B-B)

axial

A10V45 (K)

127-2 (C)

1-1/4 keyed (C)

axial

A10V71 (K)

127-2 (C)

1-1/2 keyed (C)

radial A10V100 (K)

152-4 (D)

1-3/4 keyed (D)

axial

A10V140 (K)

82-2 (A)

5/8 9T (A)

axial

A10V18(U)

82-2 (A)

3/4 11T (A-B)

axial

A10V18(S,R), 10(S)

101-2 (B)

7/8 13T (B)

axial

A10V28(S,R), 45(U,W)

101-2 (B)

1 15T ( B - B )

axial

A10V45(S,R), 60(U,W)

127-2 (C)

1-1/4 14T (C)

axial

A10V71(S,R), 100 (U,W)

127-2 (C)

1-1/2 17T (C-C) axial

A10V100(S,R), 85(S)

152-4 (D)

1-3/4 13T (D)

A10V140(S,R)

1)

sealing to mount

axial

18

28

45

71

100

140

l
l

l
l

l
l

l
l

l
l

l
l
l

l
l

61

l
l

91

l
l
l
l

Rear ports, UNC mounting screws


Opposite side ports, UNC mounting screws
Rear ports, metric mounting screws
Opposite side ports, metric mounting screws
Rear ports, UNC mounting screws
Opposite side ports, UNC mounting screws
Rear ports, metric mounting screws

Opposite side ports, metric mounting screws

ISO 2 hole
SAE 4 hole

www.FluiDyneFP.com

K081)
K381)
K211)
K01
K52
K68/K02
K04
K07/K15
K24
K17

See Thru Drives section for other options

(Pressure port B and Suction port S)

Mounting Flange

K051)

Permitted with reduced thru drive torque

Service Ports

SAE 2 hole

K031)

18

28

45

71

100

140

l
-

l
l
-

l
l
-

l
l
-

l
l
-

62
11
12

92

Ports 61,
11, 91 &
41 nonthrough
drive only

41
42

C
A
D

l = available
O = in preparation
- = not available

Variable Displacement Pump (A)A10V, Series 31

Variable Displacement Pump (A)A10V, Series 31


Fluid
1. Fluid: AW68 (Q / TCNK 12-2001)
2. Operating viscosity range

V opt = 16 mm2 / s ~ 36 mm2 / s (80-170 sus)

For optimum efficiency and service life we recommend that the operating viscosity (at operating temperature) be
selected in the range:

V opt = opt. operating viscosity 16 ~ 36 mm2 / s

Referred to tank temperature (open loop circuit).

V min = 10 mm2 / s (60 sus)


For short periods (t 1 minute) at max. leakage oil temperature of 800C (176 0F)

V max = 1000 mm2 / s


For short periods upon cold start

Limits of viscosity range


(The following values are valid for extreme operating conditions):

3. Temperature range

T min = -200C (-130F) : T max = +800C (+1760F)

4. Filtration

In order to ensure reliable operation of the axial piston unit the operating fluid must be maintained to a cleanliness
class of at least 16 / 19 to IS04406. This may be achieved with filter elements with a cleanliness code of 10m.

Installation Notes
The pump housing must be filled with fluid during commissioning and remain full when operating. The concentricity between
engine transmission shaft and pump shaft must be less than 0.05mm (0.002 in).

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31


Noise Level
Characteristics for pump

Measured in an sound chamber


Distance from microphone to pump = 3.3 ft (1m)
Measuring error: + 2 dB(A)
Fluid: Hydraulic oil to ISO VG 46 DIN 51519, t=122 F(50C)

*Sound data representative of piston pumps of this design.

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

Variable Displacement Pump (A)A10V, Series 31


DR Pressure Control
The pressure control serves to maintain a constant pressure
in the hydraulic system within the control range of the pump.
The pump therefore supplies only the amount of hydraulic
fluid required by the actuators. Pressure may be smoothly
set at the pilot valve.

Static characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F
P

(Flow)

Hysteresis and pressure increase

Setting range

Ports
280

20

(290 psi)

(4000 psi)

Operating pressure p[bar]

Pressure port

Suction port

L, L1

Case drain ports (L1 sealed)

Control Data
Hysteresis and repetitive accuracy
Size
Bar (psi)

...................... max. 3 bar (45 psi)


18

28

45

71

100

140

4 (58)

4 (58)

6 (87)

8 (116)

10 (145)

12 (174)

Pilot oil consumption...............................max. approx. 3 L/min (0.8 gpm)

10

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31


Unit Dimensions DR
Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140
Mounting of pilot
valve for clockwise
direction of rotation

Mounting of pilot
valve for anticlockwise
direction of rotation

Unit Dimensions DR
Service Ports on Side; Models 62N00 and 12N00
Sizes 18 to 140
Mounting of pilot
valve for anticlockwise
direction of rotation

Mounting of pilot
valve for clockwise
direction of rotation

Sizes

A1 mm (in)

A2 mm (in)

28

108.5 (4.27)

226.2 (8.91)

108.5 (4.27)

71

106 (4.17)

279 (10.98)

108.5 (4.27)

126 (4.964)

18
45

100

140

www.FluiDyneFP.com

110 (4.33)

108.5 (4.27)
108.5 (4.27)

245 (9.65)

344 (13.54)

A3 mm (in)

A4 mm (in)

105 (4.13)

126 (4.96)

108.5 (4.27)

146 (5.75)

108.5 (4.27)
127 (5.0)

136 (5.35)
160 (6.3)

158 (6.22)
169 (6.65)

Variable Displacement Pump (A)A10V, Series 31

11

Variable Displacement Pump (A)A10V, Series 31


DRG Pressure Control, Remote Control
Function and design for DRG.
Customer
Supplied

A pressure relief valve may be externally piped to port X for remote


control purposes. It is not, however, included with DRG control.
The differential pressure at the pilot valve is set as standard to 20
bar (290 psi) and this results in a pilot flow of (0.4gpm) 1.5 L/min.
If another setting is required (in the range 10-22 bar), please state
this in clear text.

Static Characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F
Hysteresis and pressure increase

(Flow)

Ports
B

Pressure port

Suction port

Pilot pressure port

L, L1

Case drain ports (L1 sealed)

Setting range
20

(290 PSI)

280

(4,000 PSI)

Operating pressure p [bar]

Control Data
Hysteresis and repetitive accuracy p...........max 3 bar (45 psi)
Max. pressure increases
Size

Bar (psi)

18

4 (58)

28

4 (58)

45

6 (87)

71

8 (116)

100

10 (145)

140

12 (174)

Pilot oil consumption...............................................max. approx. 4.5 L/min(1.19gpm)

12

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31


DFR/DFR1 Pressure/Flow Control
In addition to the pressure control function, the pump flow
may be varied by means of a differential pressure at the
actuator (e.g. an orifice).
Customer
Supplied

In model DFR1 the X orifice is plugged.

With DFR1
plugged

Static Characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F
P

(Flow)

Hysteresis and pressure increase

Ports

Setting range
20

280

(290 psi)

Pressure port

Suction port

L, L1

Case drain ports (L1 sealed)

Pilot pressure port

(4,000 psi)

Operating pressure p[bar]

Flow Control/Differential Pressure

Static characteristic at variable speed

(Flow)

Standard setting: 14 bar (203psi). If a different setting is


required, please state in clear text.
When port X is unloaded to tank, a zero stroke pressure
(stand by) of p = 18 +/- 2 bar (260 +/- 30 psi) results.

Control Data

(Speed)n

For pressure control technical data see DR Pressure control


Max. flow deviation (hysteresis and increase) measured at drive speed n = 1450 rpm
Size

Qmax (gpm) L/min

18

0.9 (0.24)

28

1.0 (0.26)

45

1.8 (0.48)

71

2.8 (0.74)

100

4.0 (1.06)

140

6.0 (1.6)

Pilot oil consumption DFR...........................max. approx. 3-4, 5 L/min (0.70-1.19 gpm)


Pilot oil consumption DFR1.........................max. approx. 3 L/min (0.70 gpm)
www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

13

Variable Displacement Pump (A)A10V, Series 31


Unit Dimensions DFR / DFR1 / DRG
Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140
Mounting of pilot
valve for clockwise
direction of rotation

Mounting of pilot
valve for anticlockwise
direction of rotation

Unit Dimensions DFR / DFR1 / DRG


Service Ports on Side; Models 62N00 and 12N00
Sizes 18 to 140
Mounting of pilot
valve for anticlockwise
direction of rotation

Mounting of pilot
valve for clockwise
direction of rotation

Sizes
mm (in)
18

14

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

36(1.42)

166(6.54)

105(4.13)

40(1.57)

109(4.29)

126(4.96)

7/16-20UNF-2B

28

73(2.87)

36(1.42)

108.5(4.27)

43(1.69)

209.2(8.23)

226.2(8.9)

176(6.9)

108.5(4.27)

40(1.57)

119(4.69)

136(5.35)

7/16-20UNF-2B

45

82 (3.21)

36(1.42)

108.5(4.27)

40(1.57)

229(8.98)

245(9.65)

191(7.5)

108.5(4.27)

40(1.57)

129(5.08)

146(5.75)

7/16-20UNF-2B

71

91 (3.60)

36(1.42)

106(4.17)

42(1.65)

262(10.31)

279(10.98)

219(8.6)

108.5(4.27)

40(1.57)

143(5.63)

160(6.30)

7/16-20UNF-2B

100

96.3 (3.79)

36(1.42)

108.5(4.27)

40(1.57)

327(12.87)

344(13.54)

287(11.3)

108.5(4.27)

40(1.57)

141(5.55)

158(6.22)

7/16-20UNF-2B

140

140 (5.51)

36(1.42)

27(1.06)

353(13.9)

379(14.92)

258(10.16)

127(5.0)

27(1.06)

183(7.2)

209(8.23)

9/16-18UNF-2B

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31


DFLR Pressure / Flow / Power Control
In order to achieve a constant drive torque with a varying
operating pressure, the swivel angle and with it the output
flow from the axial piston unit is varied so that the product
of flow and pressure remain constant.
Flow control is possible below the limit of the power curve.

Customer to
Supply
Maximum power curve

100

(Flow)

75
50
25

Minimum power curve

05

100 150

200 250

300

Operating pressure p[bar]

Ports
B
S

L,
X

Pressure port
L1

Suction port

Case drain ports (L1 sealed)


Pilot pressure port

The power characteristic is factory - set, so please enter details in clear text, e.g. 20kW at 1450 rpm (5HP, 1800RPM).

Control Data

For pressure control technical data see DR Pressure control.


For flow control technical data see DFR control.
Start of control.............................................from 80 bar (1,160 psi)
Pilot oil consumption....................................max. approx. 5.5 L/min (1.45 gpm)

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

15

Variable Displacement Pump (A)A10V, Series 31


Unit Dimensions DFLR
Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140
Mounting of pilot
valve for clockwise
direction of rotation

Mounting of pilot
valve for anticlockwise
direction of rotation

Power valve

Unit Dimensions DFLR


Service Ports on Side; Models 62N00 and 12N00
Size 18 to 140
Mounting of pilot
valve for anticlockwise
direction of rotation

Power valve

Sizes
mm(in)

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

Mounting of pilot
valve for clockwise
direction of rotation

A11

A12

A13

A14

28

120(4.72)

87.5(3.44)

47(1.9)

108.5(4.27)

48(1.89)

226.2(8.9)

43(1.69)

108.5(4.27)

140(5.51)

36(1.42)

108.5(4.27)

40(1.57)

119(4.69)

136(5.35)

7/16-20UNF-2B x 0.39H

45

129(5.08)

92.8(3.65)

47(1.9)

112.5(4.43)

55(2.17)

245(9.65)

40(1.57)

108.5(4.27)

155(6.10)

36(1.42)

108.5(4.27)

40(1.57)

129(5.08)

146(5.75)

7/16-20UNF-2B x 0.39H

71

139(5.47)

103.5(4.07)

47(1.9)

124(4.88)

69(2.72)

279(10.98)

42(1.65)

106(4.17)

218.8(8.61)

36(1.42)

108.5(4.27)

40(1.57)

143(5.63)

160(6.30)

7/16-20UNF-2B x 0.39H

100

145(5.71)

112.6(4.43)

47(1.9)

132.5(5.22)

110.8(4.36)

344(13.54)

40(1.57)

108.5(4.27)

250(9.84)

36(1.42)

108.5(4.27)

40(1.57)

148(5.83)

165(6.50)

M14 x 1.5-6H

140

148(5.83)

140(5.51)

140(5.51)

99(3.90)

379(14.92)

209(8.23)

183(7.2)

127(5.00)

27(1.06)

183(7.29)

209(8.23)

9/16-18UNF-2B x 0.51H

16

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Mounting Dimensions, Size 18, Series 31


ServiceUnit
Ports
on Side; Size
Non 18,
Through
Drive, Models 62N00 and 12N00
dimensions,
Series 31
Without Considering Adjustment

Dimensions in inches (mm).

(A)A10VSO 18, Serive ports on side, Models 62N00 & 12N00


(A)A10VSO 18, Service ports on side, Models 62N00 & 12N00
1.87 (47.6)

3.27 (83)
V
(11
)

0.25 (6.3)
Flange SAE J744
82-2 (A)

0.
43

2.48 (63)

3.2500
DIA 3.2479 (82.55 h8
)

0.79 (20)

View W

0.87 (22.2)

4.19 (106.4)
5.98 (152)

5.71 (145)

mech.
displacement
limiter

7.68 (195)
W

0.98 (25)

L1

1 .69 (43)

2.06 (52.4)

0.45 (11.5)

View V

2.60 (66)
2.52 (64)

2.48 (63)

2.
64

(6
7)

12N00

4 x M10 (0.67)
(17) deep

12N00

4 x M10 (0.67)
(17) deep

1.03 (26.2)

Shaft
Shaft ends
ends
S Splined shaft 3/4 in 11T
16/32 DP 2)
SAE J744-19-4 (A-B)

R Splined shaft 3/4 in 11T


16/32 DP 2)
SAE J744-19-4 (A-B)

0.02

Centering 3)
R3.15x6.7 DIN332

DIA 0.7500 (19.05


0.7492

1.13 (28.6)
0.10 (2.5)

1.30 (33)

3/4 in

3/4 in

0.83 (21.1)

0.1884
0.1874
(4.76 +0.025 )

1/4-20UNC-2B

K Parallel with key


ISO 3019-1 19-1

0.55
(14)

0.87 (22)

1.50 (38)

1.50 (38)

U Splined shaft 5/8 in 9T


16/32 DP 2)
SAE J744-16-4 (A)

Centering 3)
R3.15x6.7 DIN332

1.18 (30)

0.62 (15.8)
0.94 (23.8)
1.25 (31.8)

usable spline length


1.61 (41)

2) ANSI B92.1a-1976, 30 pressure angle, flat root side fit, flank centering, tolerance class 5

Ports

Designation

Port for

Standard

Size

Ports

B
S
L,L1
X
X

Pressure port (standard pressure range)


SAE J518
in bolt holes
68
PressureThreading
port (standard
pressure range) ISO
SAE
S
Inletinport
(standard
Threading
bolt
holespressure range)
Threading in bolt holes

3/4 in
UNC-2B;
J5183/8-16
3/4
in 0.79 (20) deep

SAE
J518 68
ISO
ISO 68

Peak

Pressure
Tightening torques,
max. 2)
[psi (bar)]

29 lb-ft (40 Nm)

1 in 3/8-16 UNC-2B; 0.79 (20) deep


3/8-16 UNC-2B; 0.79 (20) deep
29 lb-ft (40 Nm)

5100 (350)

InletL/L
(standard
pressure range )
SAE J5189/16-18
1 UNF-2B
in
C ase drain port (L 1 plugged)
ISO 11926
59 lb-ft (80 Nm)
1
Threading
in
bolt
holes
ISO
68
3/8-15
UNC-2B; 0.79 (20) deep 75 (5)
1)
ANSI B92.1a-1976, pressure angle 30 , flat root side fit, tolerance class 5

See
safety information
Case
drain
(L1 plugged)
ISO 11926 9/16-18
3)
Axial locking of
the coupling e.g. via clamping coupling or radial mounted binding screw
2)

UNF-2B

Tightening
Torque Max
[lb-ft (Nm)]

30 (2)

29 (40)
29 (40)
59 (80)

Pilot Pressure

ISO 11926

7/16-20 UNF-2B; 0.39 (10) deep 5100 (350)

29 (40)

Control pressure for DG control

DIN 3852

R 1/4 in

48 (70)

1740 (120)

1) Dependent on the installation position, port L or L1 must be connected


www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

17

Mounting Dimensions, Size 28, Series 31


18/44

Bosch Rexroth Corporation

(A)A10V(S)O | RA 92701-A/12.09

Service Ports at Side and Rear; Non Through Drive

Dimensions,
28
Without Consideringsize
Adjustment

Valve
Valve mounting
mountingfor
for
counter clockwise
counter clockwise
rotation

Port
Portplate
plate62/12
62

45

.91

3.54 (90 )

DIA 4.0000
)
3.9979 (101.6 h8

2.87 (7 3)
1.87 (4 7.6)
0.79
B
(20)
X

3.11 (79)

1.77
(45)

0.55 (14)
1.57 (40)

L1

1.25 (32)
2.31
(58.7)

6.69 (170 )
8.23 (20 9)
8.90 (226)

rotation

2.31 (58.7)
1.26 (32)

1.87
(47.6)

0.79 (20)

View
ViewW
W

Valve
Valvemounting
mountingfor
for
counter clockwise
counter clockwise
rotation

View
ViewVV

0.87 (22.2)

0.87 (22.2)

Port plate 61

1.77
(45)

6.46 (164)
7.64 (194)

Port plate 61/11

0.37 (9.5)
0.25 (6.3)

5.75 (146)
6.46 (164)
3.29 (83.5)
4.68 (119 )
5.35 (13 6)

L1

4)
(7

1.69 (43)
max. 4.45
(113)

0.55 (14)
1.57 (40)

0.
DI
A

3.15 (80)

45

3.15 (80)

DIA 4.0000
)
3.9979 (101.6 h8

6.8
( 5
17
4)

1.57 (40)
max. 4.33 (110)
2.91 (74)

55

Flange SAE J744


101-2 (B)

rotation

1.19 (30.2)

5.47 (13 9)
3.54 (90 )
L

(14
)

0.25 (6.3)
0.37 (9.5)

1.19
(30.2)

11/12N00 threads,
M10; 17 deep

18

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Drive shafts

Drive shafts

K Parallel with key


Mounting Dimensions,
Size 28, Series 31
ISO 3019-1 22-1

K Parallel with key


ISO 3019-1 22-1

(A)A10V28 Shaft, Metric Mount, and Port Dimensions


without considering adjustment

Shaft P, Flange A
Z ; View W

RA 92701-A/12.09

View H

| (A)A10V(S)O

Bosch R

Dimensions, size 28
1)

0.63 (16 )
0.98 (25)

0.63 (16 )

Usuable spline length

0.98 (25)
1.61 ( 41)

1.61 ( 41)

DIA 3/4 in
1/4-20UNC-2B

1/4-20UNC-2B

DIA 3/4 in

0.55 (14)
0.55 ( 14 )
Usuable spline length
Usuable
spline length
0.83 ( 21)
1.18 (3
0)
1.50 (3 8)
1.50 (3 8)

0.55 (14)
1.18 (3 0)
1.50 (3 8)

1)

DIA 3/4 in
1/4-20UNC-2B

W Splined Shaft 3/4 in 11T 16/32 DP


SAE J744 - 19-4 (A-B)

1)

1/4-20UNC-2B

DIA 3/4 in

1.30 (33. 1)
Usuable spline length
1.61 (41)

DIA 7/8 in
1/4-20UNC-2B

0.63 (16 )
0.99 (25. 1)
1.30 (33. 1)
1.61 (41)

U Splined Shaft 3/4 in 11T 16/32 DP


SAE J744- 19-4 (A-B)

Drive shafts

K Parallel with key


3019-1
22-1
0.63ISO
)
K(16
Parallel
with
key
ISO 3019-1
22-1
0.99 (25.
1)

1)

DIA 7/8 in
1/4-20UNC-2B

R Splined shaft 7/8 in 13T 16/32 DP

DIA 7/8 in
1/4-20UNC-2B

DIA 7/8 in
1/4-20UNC-2B

S Splined shaft 7/8 in 13T 16/32 DP


SAE J744- 22-4 (B)

0.55 ( 14 )
0.83 ( 21)
1.50 (3 8)

Ports (A)A10V 28
Designation

Port for

Standard

Size

DIA 7/8 in
1/4-20UNC-2B

1) ANSI B92.1a-1976, 30 pressure angle, flat root side fit, flank centering, tolerance class 5

Peak press.
[psi (bar)]

Service line (standard pressure


range) Fixing thread

SAE J518
ISO 68

3/4 in
3/8-16 UNC-2B; 0.79 (20) deep

Inlet (standard pressure range )


Fixing thread

SAE J518
ISO 68

1 1/4 in
0.99 (25. 1)
7/16-14 UNC-2B; 0.94 (24) deep

L,L1

Case drain (L1 plugged)

ISO 11926

1.30 (33. 1)
3/4-16 UNF-2B; 0.47 (12) deep
1.61 (41)30 (2)

Pilot pressure

ISO 11926

7/16-20UNC-2B; 0.47 (12) deep

Control pressure for DG control

DIN 3852

R 1/4 in

www.FluiDyneFP.com

IA 3/4 in

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected

1/4-20UNC-2B

0.63 (16 )

5100 (350)
75 (5)

Tightening
Torque, Max
[lb-ft (Nm)]

State

29 (40)

48 (85)

O
Usuable spline length

118 (160)

O1)

5100 (350)

29 (40)

1740 (120)

48 (70)

Variable Displacement Pump (A)A10V, Series 31

19

Mounting Dimensions, Size 45, Series 31


22/44

Bosch Rexroth Corporation

(A)A10V(S)O | RA 92701-A/12.09

Service
Ports at Side
Dimensions,
sizeand
45 Rear; Non Through Drive
Without Considering Adjustment
Port Plate 62/12 N00

45

3.17 (80.5)

mounting
mountingfor
for counter
counter
clockwise
rotation
clockwise rotation

0.56 (14.3)
1.77 (45)

1.57
(40)
2.75
(69.9 )

Variable Displacement Pump (A)A10V, Series 31

Controlvalve
valve
Control
mounting
mountingfor
forcounter
counter
clockwise
clockwise rotation
rotation

1.57 ( 4 0 )

2 .7 5 (69.9)

View
ViewWW

0 .9 8
(25) 2 .0 6
(52.4)

11/12N00 threads M10; 17 deep

1.97
(50)
S

7.44 (18 9)
9.65 (245)

1.40
(35.7)

1.97
(50)

L1

1.03 (26.2)

3.23 (82)
2.06 (52.4)
0.98
(25)

1.03 (26.2)

3.46 (88)

40

max. 4.33 (110)

8.98 (228)
3.78 (96 )
L

View Z

1.40
(35.7)

DIA 4.0000
3.9979 (101.6

h8)

45

5.75 (146)
7.24 (184)
3.68 (93.5)
5.08 (129)
5.75 (146)
Control
Control valve
valve

7.24 (184)
8.62 ( 219 )

View
ViewV V

20

L
X

3.54 (90)
L1

Port Plate 61/11 N00

Flange SAE J744


101-2 (B)

0.

3.54 (90)

0.56 (14.3)
1.77 (45)

0.37 (9.5)
0.25 (6.3)

)
14

5(

1.57 (40)
max. 4.33 (110)

3)
(8
27
3.

h8)

6.06 (154)
3.78 (96 )
L

DIA 4.0000
3.9979 (101.6

Flange SAE J744


101-2 (B)

0.37 (9.5)
0.25 (6.3)

11/12N00 threads M12; 20 deep

www.FluiDyneFP.com

Drive shafts
S Splined shaft 1 in 15T 16/32 DP
SAE J744 - 25-4 (B-B)

1)

R Splined shaft 1 in 15T 16/32 DP


SAE J744 - 25-4 (B-B)

Mounting Dimensions, Size 45, Series 31


RA 92701-A/12.09

Bosch Rexroth Corporation

| (A)A10V(S)O

Dimensions, size 45
Dimensions, size 45
(A)10V45 Shaft, Metric Mount, and Port Dimensions
Drive shafts

Drive shafts

DIA 7/8in
1/4-20UNC-2B

1.18 (3 0)
1.50 (3 8)
1.81 (45.9)

0.63 (16 )

Usable
1.16 (29.5)
Usable
1.16 (29.5) spline length
1.81
(45.9)
spline length

0.98 (25. 1)
1.61 ( 41)

W Splined
shaftshaft
7/8 7/8
in 13T
DP
WSplined
in 13T16/32
16/32 DP
SAE J744
-J744
22-4
(B)(B )
SAE
22-4
1)
WSplined shaft 7/8 in 13T 16/32 DP
SAE J744 - 22-4 (B )
0.63 (16 )
1)

0.63 (16 )

Usable
0.98 (25)
spline length
1.61 ( 41)

0.635(16 )
0.98flank
(25. 1)
ANSI B92.1a-1976, 30 pressure
angle, flat root side fit,
centering, tolerance class
0.63 (16 )
1.61 ( 41)

0.98 (25. 1)
1)

1)

DIA 7/8in
1/4-20UNC-2B

0.63 (16 )

DIA 7/8in
1/4-20UNC-2B

U Splined shaft 7/8 in 13T 16/32 DP

DIA 7/8in
1/4-20UNC-2B

WSplined shaft 7/8 in 13T 16/32 DP 1)


SAE J744 - 22-4 (B )
0.63 (16 )

1.81 (45.9)

U Splined shaft 7/8 in 13T 16/32 DP SAE


U Splined shaft 7/8 in 13T 16/32 DP 1) J744 - 22-4 (B)
SAE J744 - 22-4 (B)
SAE J744 - 22-4 (B)

1)

DIA 1in
1/4-20UNC-2B

0.63 (16 )
1.18 (3 0)
1.50 (3 8)
1.81 (45.9)

1)

1.81 (45.9)

DIA 7/8in
1/4-20UNC-2B

1)

DIA 1in
1/4-20UNC-2B

U Splined shaft 7/8 in 13T 16/32 DP


SAE J744 - 22-4 (B) 0.63 (16 )

23/44

Usable
1.16 (29.5)
spline length

DIA 7/8in
1/4-20UNC-2B

DIA1 in
1/4-20UNC-2B

1.50 (3 8)
1.81 (45.9)

1) shaft
shaft
1 in 115T
16/32
DP
Splined
in 15T
16/32(16
DP)
R Splined shaft 1 inR15TSplined
16/32R DP
0.63
25-4
(B-B)
SAE -J744
- 25-4
(B-B)
SAE J744 - 25-4 (B-B) SAE J744

1)

DIA1 in
1/4-20UNC-2B

0.63 (16 )
S Splined shaft 1 in 15T 16/32 DP 1)
S Splined shaft 1 in 15T 16/32 DP S Splined shaft 1 in 15T 16/32 DP
SAE J744 - 25-4 (B-B)
1.18 (3 0)
SAE J744 - 25-4 (B-B)
SAE J744 - 25-4 (B-B)

23/44

Bosch Rexroth Corporation

DIA 1in
1/4-20UNC-2B

| (A)A10V(S)O

DIA1 in
1/4-20UNC-2B

RA 92701-A/12.09

1)

0.63 (16 )
Usable
0.98 (25)
spline length
1.61 ( 41)

Usable
0.98 (25)
K Parallel with key
spline length
1.61 ( 41) ISO 3019-1 25-1

1.61
ANSI
B92.( 141)
a-1976, 30 pressure angle, flat root side fit, flank centering, tolerance class 5

1) ANSI
B92.1a-1976,
30
pressure
angle,
flatside
root
fit, flank centering,
tolerance
class 5
1) ANSI
B92.1a-1976, 30
pressure
angle,
flat root
fit, side
flank centering,
tolerance class
5

KK Parallel
Parallel
with
with
key key
ISO
3019-1
25-1
ISO 3019-1
25-1

K Parallel with key


ISO 3019-1 25-1

Shaft P, ISO Flange A


25 mm Shaft

Ports

Ports
Ports (A)A10V45
Ports

Designation

Port for

Standard

Size

Peak press.
[psi (bar)]

Tightening
Torque, Max
[lb-ft (Nm)]

State

29 (40)

66 (90)

Service line (standard pressure


range)
Fixing thread

SAE J518
ISO 68

1 in
3/8-16 UNC-2B; 0.71 (17) deep

5100 (350)

Inlet (standard pressure range)


Fixing thread

SAE J518
ISO 68

1 1/2 in
1/2-13 UNC-2N; 0.87 (22) deep

75 (5)

L, L1

Case drain

ISO 11926

7/8-14 UNF-2B

30 (2)

177 (240)

O1)

Pilot pressure

ISO 11926

7/16-20 UNF-2B; 0.39 (10) deep

5100 (350)

29 (40)

Control pressure for DG control

DIN 3852

R 1/4 in

1740 (120)

48 (70)

1) Dependent on the installation position, Port L or L1 must be connected


O = Must be connected
www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

21

Mounting Dimensions, Size 71, Series 31


26/44
26/44

(A)A10V(S)O | RA 92701-A/12.09

Bosch
Bosch Rexroth
Rexroth Corporation
Corporation

(A)A10V(S)O
(A)A10V(S)O || RA
RA 92701-A/12.09
92701-A/12.09

Ports on Side and Rear; Non Through Drive


ize 71Service
Dimensions,
size 71
Without
Considering Adjustment

Before finalizing your design request


a certified installation drawing.
Dimensions in inches and (mm).

Before
Before finalizing
finalizing your
your design
design request
request
certified installation
aa certified
installation drawing.
drawing.
Dimensions in
in inches
inches and
and (mm).
(mm).
Dimensions

Pressure
andand
flowflow
control;
clockwise
rotationrotation
d flow control;DFR/DFR1
clockwise
rotation
DFR/DFR1
Pressure
control;
clockwise
With
With
port
plate
92
Withport
port plate
plate 92
92 (others available)

1.69
(42.9)

S
B
B

L1
8.78 (223)
10.98 (2 79 )

3.62 (92)
1.03(262)
10.31
(262) (26.2)
10.31
0.98
(25)
4.53
(115
)
B
4.53 (115 )

L
B

LL

Z
S

0.71
(18
0.71
(18 ))
2.09
2.09 (5
(5 3)
3)

S
L1
L1

1.97
(50)
8.78
8.78 (223)
(223)3.06
10.98
79
10.98 (2
(2(77.8)
79 ))

Variable Displacement Pump (A)A10V, Series 31

XX
2.06 (52.4)
1.57
1.57(40)
(40)
2.28 (58)
max.
max.4.33
4.33 (110)
(110)

1.57 (40)
max. 4.33 (110)

5.0000
DIA
DIA5.0000
(127 h8
))
h8
4.9975
4.9975 (127

0.50
0.50 (12
(12 .7)
.7)
0.24
0.24 (6
(6 ))
Flange SAE
SAE J744
J744
L Flange
127-2 (C)
(C)
127-2
L

XX

View Z
Z
View
Z
View

With port
port plate
plate 91
91
With
91
With
port
plate

10.31 (262)
4.53 (115 )

View F

SS

View Z

With port plate 91

(181)
(181)
(( 210
210 ))
5.63
5.63 (143)
(143)
6.30
6.30 (160
(160 ))

1.69
1.69
(42.9)
(42.9)

2.06
2.06 (52.4)
(52.4)
0.98
0.98 (25)
(25)

3.06 (77.8)
1.97
(50)

1.03
(26.2)

2.06 (52.4)
0.98 (25)

1.57
1.57(40)
(40)
3.62
3.62(92)
(92)
max.
max.4.33
4.33(110)
(110)

))

4.09
4.09(104)
(104)

1.57 (40) DDIAIA


00. . 4.33 (110)
3.62 (92)
max.
7711
33
(1(188 .8.866
)) (9(988

3
(18 .86
) (9

0.
71
A

L1
L1

3.62
3.62 (92)
(92)
1.03
1.03
0.98
B
B 0.98

(26.2)
(26.2)
(25)
(25)
2.06
2.06 (52.4)
(52.4)
2.28
2.28 (58)
(58)

4455

4455

7.13 (181)
7.13
7.13
8.27 ( 210 )
8.27
8.27
8.54
(2
8.54
(2 17
17 ))
4.23
(107.5)
5.63 (143)
4.23
4.23 (107.5)
(107.5)
10
10 ..1
12
2 (257)
(257)
6.30 (160 )
Valve mounting for
Valve
mounting for
for
Valve mounting
mounting
for
Valve
counter
counter clockwise
counter clockwise
clockwise
counter
clockwise
W
W(F)
rotation
W
rotation
rotation
rotation
View
W
View W
View
V
View
W
View View
E
View V
W
Model 92

8.54 (2 17 )
10 .12 (257)

22

45

45LL

4.09 (104)
0.71
(18
0.71
(18 ))
2.09
2.09 (5
(5 3)
3)

View V
View
V
Model 92

1
(18 )
9 (5 3)

X
X

3.06
3.06(77.8)
(77.8)
1.97
1.97
(50)
(50)

L1

V
V

BB

X
X
Z
Z

1.69 (42.9)
2.28 (58)

1
(18 )
9 (5 3)

5.0000
DIA
DIA5.0000
(127 h8
))
h8
4.9975
4.9975 (127

V(E)

7.20
7.20 (18
(18 3)
3)
4.53
4.53 (115
(115 ))
LL

DI

4.09 (104)

V0.50
0.50 (12
(12 .7)
.7)
0.24
0.24 (6
(6 ))
XFlange
Flange SAE
SAE J744
J744
127-2
127-2 (C)
(C)

1.03
1.03
(26.2)
(26.2)

7.20 (18 3)
4.53 (115 )

4.09
4.09(104)
(104)
X

With port plate 92

Valve mounting for


counter clockwise
rotation

SS

SS

1.97
1.97
(50)
(50)
3.06
3.06
(77.8)
(77.8)

1.69
1.69(42.9)
(42.9)
2.28
2.28 (58)
(58)

orporation

Valve
mounting
for
Valve
Valve mounting
mounting for
counter
clockwise
counter
counterclockwise
clockwise
rotation
rotation
rotation

www.FluiDyneFP.com

DIA 1 1/4in
5/16-18UNC-2B

Mounting Dimensions, Size 71, Series 31


(A)10V71 Shaft, Metric Mount, and Port Dimensions
R Splined shaft 1 1/4 in 14T 12/24 DP
SAE J744- 32-4 (C) 2)

1.18 (3 0)

DIA 1 in
1/4-20UNC-2B

1.81 (45.9)

5/16-18UNC-2B

1/4-20UNC-2B

DIA 1 in

DIA 1 1/4in
5/16-18UNC-2B

DIA 1 1/4in

2.18 (55.4)

1.81 (45.9)

DIA 1 in
1/4-20UNC-2B

1.50 (3 8)

0.63 (16 )

0.63 (16 )

1.18 (3 0)

Usable
spline length

1.50 (3 8)

1.18 (3 0)
1.81 (45.9)

K Parallel with key


ISO 3019-1 32-1

0.63 (16 )
Usable
spline length

1.50 (3 8)

1.50 (3 8)

1.18 (3 0)

Shaft P, ISO Flange A


(45.9)
32 mm 1.81
Shaft

2.18 (55.4)
W Splined shaft 1 in 15T 16/32 DP
) (B-B) 2)
SAE0.63
J744-(16
25-4

0.63 (16 )

2.18 (55.4)

DIA 1 in
1/4-20UNC-2B

DIA 1 in

1.50 (3 8)

0.75 (19 )

Usable
spline length

1.50 (3 8)

DIA 1 in

5/16-18UNC-2B

DIA 1 1/4in
1/4-20UNC-2B

0.75 (19 )

Usable
spline length

0.75 (19 )
1.56 (39.5)
1.87 (47.5)
2.18 (55.4)

0.75 (19 )
Usable
spline length

U Splined shaft 1 in 15T 16/32 DP


SAE J744- 25-4 (B-B) 2)

1/4-20UNC-2B

0.75 (19 )
1.56 (39.5)
1.87 (47.5)
2.18 (55.4)

5/16-18UNC-2B

DIA 1 1/4in

DIA 1 1/4in
5/16-18UNC-2B

S Splined shaft 1 1/4 in 14T 12/24 DP


SAE J744- 32-4 (C) 2)

0.75 (19 )
1.56 (39.5)
1.87 (47.5)
2.18 (55.4)

1.18 (3 0)
1.81 (45.9)

0.63 (16 )
Usable
spline length

1.18 (3 0)
1.81 (45.9)

2) ANSI B92.1a-1976, 30 pressure angle, flat root side fit, flank centering, tolerance class 5

Ports (A)A10V71
Designation

B
S

Port for

Standard

Size

Service line (standard pressure range)


Fixing thread

SAE J518
ISO 68

1 in
3/8-16 UNC-2B; 0.71 (18) deep

Intlet (standard pressure range)


Fixing thread

SAE J518
ISO 68

2 in
1/2-13 UNC-2B; 0.87 (22) deep

L, L1

Case drain

ISO 11926

7/8-14 UNF-2B

Pilot pressure

Control pressure for DG control

ISO 11926

7/8-14 UNF-2B; 0.39 (10) deep

DIN 3852

R 1/4 in

Peak press.
Max
[psi (bar)] Tightening
Torque
[lb-ft (Nm)]

State

5100 (350)

29 (40)

75 (5)

66 (90)

30 (2)

177 (240)

O1)

29 (40)

5100 (350)

1740 (120)

48 (70)

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected
www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

23

Mounting
Dimensions, Size 100, Series 31
30/44
Bosch Rexroth Corporation

(A)A10V(S)O | RA 92701-A/12.09

30/44
Bosch Rexroth
Corporation
Dimensions,
size
100

(A)A10V(S)O | RA 92701-A/12.09

Service Ports on Side & Rear; Non Through Drive


Without Considering Adjustment

Dimensions, size 100


Port plate 62

0.79 (20)

)
(1
06

L1

10.83 (275)
12.48 (317)
L1
3.74 (95)
10.83 (275) W
12.48 (317)

Valve mounting for counter


clockwise rotation
View V

11/12N00 threads M14; 19 deep

1.25 (31.8)
B

View
1.25Z(31.8)

6.89 (175)
0.24 (6)

0.79 (20)
3.74 (95)

0.79 (20)

L1

11.34 (288)
12.87 (327)
13.54
L1 (344)
3.74 (95)
11.34 (288)
12.87 (327)
13.54 (344)

View W
S
2.00
(50.8)
S

11/12N00 threads M14; 19 deep

3.90 (99)
2.63 (66.7)
View
Z Z
View
1.26 (32) B
3.90 (99)
2.63 (66.7)
1.26 (32) B

DIA 5.0000
4.9975 (127h8)
DIA 5.0000
4.9975 (127h8)

0.50 (12.7)

1.57 (40)
1.57 (40)max. 4.33 (110)
max. 4.33 (110)

Port plate 61

Flange SAE J744


127-2 (SAE C)

7.13 (181)
8.27 (210)
4.65 (118) 5.84 (148.4)
6.50 (165)
Valve
counter7.13 (181)
Valvemounting
mounting for
for counter
clockwise rotation
8.27 (210)
clockwise rotation
4.65 (118) 5.84 (148.4)
View
View
View W
W
6.50 (165)
ViewVV

0.50 (12.7)Port plate


6.89
61 (175)
0.24
(6)
Flange SAEPort
J744Plate 61/11
NOO
127-2 (SAE C)

4.1
7

45

2.00
(50.8)

1.25 (31.8)
2.00 (50.8)
2.00 (50.8)
2.16 (55)1.25
2.16(31.8)
(55)
2.16 (55) 2.16 (55)

3.74 (95)

45

3.50 (88.9)
3.50 (88.9)2.36 (60)
2.36 (60)

0.79 (20)

(1
06

Flange SAE J744


127-2 (SAE C)

4.1
7

1.26 (32)
1.26 (32)
2.63
2.63
(66.7)
(66.7)

9.84 (250)
6.89 (175)

0.24 (6)

5.98 (152)
5.98 (152)
0.69 (17.5)
0.69 (17.5)

DIA 5.0000
4.9975 (127h8 )
DIA 5.0000
4.9975 (127h8 )

Flange SAE J744


127-2 (SAE
C) (12.7)
0.50

V
X
3.94 (100)3.94 (100)
3.94 (100)3.94 (100)

0.50 (12.7)Port plate 62


9.84 (250)
0.24 (6)
6.89 (175)

1.57 (40)
1.57(95)
(40) max. 4.33 (110)
3.74
3.74 (95) max. 4.33 (110)

Port Plate 62/12 NOO

S
2.36 (60)
3.50
(88.9)
S
2.36 (60)
3.50
Valve mounting for counter
(88.9)
clockwise rotation

Valve mounting for counter


Valve mounting
for counter
clockwise
rotation

clockwise rotation

24

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

RA 92701-A/12.09
| (A)A10V(S)O
RA 92701-A/12.09
| (A)A10V(S)O

Bosch Rexroth
Corporation
Bosch Rexroth
Corporation31/44 31/44

Mounting Dimensions, Size 100, Series 31

Dimensions,
sizesize
100 100
Dimensions,
Drive shafts
Drive shafts

Drive Shafts

S Splined
shaft 1 1/2
in117T
S Splined
shaft
1/212/24
in 17TDP
12/241) DP
Splined shaft 1 1/2 in 17T 12/24 DP1)
SAESJ744
- 38-4
SAE
J744(C-C)
- 38-4 (C-C)
1)

K Parallel
with key
K Parallel
with key
K Parallel with key
ISO 3019-1
38-1 38-1
ISO 3019-1

1)

ISO 3019-1 38-1

DIA1 1/2in
7/16-14UNC-2B

DIA1 1/2in
7/16-14UNC-2B

SAE J744 - 38-4 (C-C)

1.10 (28)1.10 (28)


1.72 (43.6)
1.72 (43.6)
2.13 (54)
2.13 (54)
2.44 (62.44
1.9) (6 1.9)

DIA 1 1/4in
5/16-18UNC-2B

DIA 1 1/4in
5/16-18UNC-2B

1)

DIA 1 1/4in
5/16-18UNC-2B

J744 - 32-4 (C)

W Splined
shaft 1 1/4
in 114T
W Splined
shaft
1/412/24
in 14TDP
12/241)DP 1)
W Splined shaft 1 1/4 in 14T 12/24 DP1) SAE
SAEJ744
J744
32-4
(C)
SAE
J744
32-4
(C)
- 32-4 (C) 1)

0.75 (190.75
) (19 )
usable spline
usablelength
spline length1.38 (35)
1.38 (35)

0.75 (190.75
) (19 )
1.38 (35)
1.38 (35)

2.18 (55.4)
2.18 (55.4)

2.18 (55.4)
2.18 (55.4)
1)

1) ANSI

DIA 1 1/4in
5/16-18UNC-2B

U Splined
shaft 1 1/4
in 114T
U Splined
shaft
1/412/24
in 14TDP
12/241)DP 1)
SAE
J744
- 32-4
U Splined
shaft
1/4 in
SAE
J744(C)
-132-4
(C)14T 12/24 DP1) SAE

B92.1a-1976, 30 pressure angle, flat root side fit, flank centering, tolerance class 5

1) ANSI
ANSI B92.
1a-1976,
30 pressure
angle, flat
rootflat
side
fit, side
flankfit,
centering,
tolerance
class 5 class 5
B92.1a-1976,
30 pressure
angle,
root
flank centering,
tolerance

Shaft P, ISO Flange A


4040mm
mm0 Shaft
Shaft

Ports Ports

Ports (A)A10V 100

Designation
forfor
Designation
Port Port
forPort
Designation

Standard
Standard
Size
Standard

2)Size

Max
Peak
State
Peak press.
State State
Peakpress.
press.
3)
3) Tightening
[psi
[psi (bar)]
[psi(bar)]
(bar)]
Torque
B
ServiceService
line (high
range) range)
SAE J518
1 1/4 in 1 1/4 in
B
linepressure
(high pressure
SAE J518
[lb-ft
Fixing thread
ISO 68 ISO 681/2-13 UNC-2B;
0.75 (19)0.75
deep
O
Fixing thread
1/2-13 UNC-2B;
(19) deep 5100 (350)
5100 (350)
O (Nm)]
B
Service line (high pressure range)
SAE J518 1 1/4 in
O
S
Intlet (standard
pressure
range) range)
SAE J518
2 1/2 in2 1/2 in
S
Intlet
(standard
pressure
SAE68
J518
66 (90)
Fixing
thread
ISO
1/2-13 UNC-2B; 0.75 (19) deep 5100 (350)
Fixing thread
ISO 68 ISO 681/2-13 UNC-2B;
1.06 (17)1.06
deep
Fixing thread
1/2-13 UNC-2B;
(17) deep 75 (5) 75 (5) O
O
S
Intlet (standard pressure range)
SAE J518 2 1/2 in
O
4)
4)
L
Case
drain
ISO
11926
1
1/16-12
UNF-2B
30
(2)
O
L
Case
drain
ISO 68
11926 11/2-13
1/16-12UNC-2B;
UNF-2B 1.06 (17) deep 7530(5)
(2)
O 66
(90)
Fixing
thread
ISO
4)
4)
L 1L, L L 1
CaseCase
drain
ISO 11926
1 1/16-12
UNF-2B
30 (2)3030(2)
Case
drain
ISO 11926
11926
111/16-12
UNF-2B
(2) plugged
plugged
265 (360)
drain
ISO
1/16-12
UNF-2B
O1)
1
X
Pilot pressure
ISO 11926
7/16-20 7/16-20
UNF-2B;UNF-2B;
0.39 (10)0.39
deep
5100 (350)
O
X
Pilot pressure
ISO 11926
(10) deep
5100 (350)
O
59 (80)
X
Pilot pressure
ISO 11926 7/16-20 UNF-2B; 0.39 (10) deep 5100 (350)
O
X
ControlControl
pressure
for DG control
DIN 3852
R 1/4 inR 1/4 in
1740 (120)
O
X
pressure
for DG control
DIN 3852
1740 (120)
O
59 (80)
X
Control pressure for DG control
DIN 3852 R 1/4 in
1740 (120)
O
2) For the
2) For
max.
tightening
torquestorques
the instructions
on pageon
44page
must44
bemust
observed.
the
max. tightening
the instructions
be observed.
3) Application
3) Application
dependent
spikesposition,
can
occur..
Please
consider
this be
when
selecting
measuring
equipment
or fittings
pressure
spikes
canport
occur..
Please
consider
this
when selecting
measuring
equipment
or fittings
1) Dependent
ondependent
thepressure
installation
L or
L1 must
connected
4) Dependent
4) Dependent
on
the
installation
position,
port
L
or
L
must
be
connected
on
the
installation
position,
port
L
or
L
must
be
connected
1
1
O = Must be connected
O = Must
beMust
connected
(plugged
on delivery))
O=
be connected
(plugged
on delivery))
www.FluiDyneFP.com
Variable Displacement Pump (A)A10V, Series 31 25

Size

2)

Mounting Dimensions, Size 140, Series 31


Service ports on side; Non through drive, Models 62N00 and 12N00

mech.
displacement
limiter max.

View W
Flange SAE J744
152-4 (D)

12N00 M12;
17 deep
mech.
displacement
limiter min.
mech.
displacement
limiter min.

View V

12N00 M14,
19 deep

mech. displacement
limiter
Shaft end
K Parallel with key
ISO 3019-1 44-1

Designation

S Splined shaft 1 3/4 in 13T 8/16 DP


SAE J744-44-4 (D)

Port for

Standard

Pressure port (standard pressure range) SAE J518


Threading in bolt holes
ISO 68

mech.
displacement
limiter max.

Size

1 1/4 in
1/2-13 UNC-2B; 0.75 (24) deep

Peak
Pressure
[psi (bar]

Max
Tightening
Torque
[lb-ft (Nm)]

5100 (350)

66 (90)
66 (90)

Case drain (L1 plugged)

SAE J518
ISO 68

2 1/2 in
1/2-13 UNC-2B; 0.94 (24) deep

75 (5)

L,L1

Inlet (standard pressure range)


Threading in bolt holes

Pilot pressure

ISO 11926

9/16-18 UNF-2B; 0.51 (13) deep

5100 (350)

59 (80)

Control pressure for DG control

DIN 3852

M14 x 1.5; 0.47 (12) deep

1740 (120)

59 (80)

ISO 11926

1 1/16-12 UNF-2B

30 (2)

265 (360)

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected
26

Variable Displacement Pump (A)A10V, Series 31

www.FluiDyneFP.com

Through Drives
26/36

Bosch Rexroth AG

| Industrial Hydraulics

(A )A10VSO | RA 92 711/10.07

Through Drive Mounting Options


Through
Shaft Torque
Data drives
Axial piston units A10V can be supplied with a through drive as shown in the ordering code on page 3. The type of through
drive is determined by codes (K40-K...). If the combination pump is not mounted in the factory, the simple type code is sufficient.
Included in this case are: shaft coupler, seals, and if necessary an adapter flange.
Maximum permissible input and through drive torque.

T tot

T thr

The drive torques for pump 1 and pump 2 can be split up as required. However the max. permissible input torque T tot as well as
the max. permissible through drive torque Tthr may not be exceeded.
Max. perm. input torque T
With
U shaft U

18

tot

28

45

71

100

140

T tot

lb.ft (Nm)

43 (59)

- (-)

139 (188)

- (-)

With shaft K

tot

lb.ft (Nm)

77 (104)

107 (145)

156 (212)

319 (433)

553 (750)

875 (1186)

With shaft S

tot

lb.ft (Nm)

92 (124)

146 (198)

235 (319)

462 (626)

814 (1104)

1195 (1620)

With shaft R

tot

lb.ft (Nm)

111 (150)

166 (225)

295 (400)

475 (644)

- (-)

77 (104)

107 (145)

156 (212)

319 (433)

553 (750)

875 (1186)
934 (1266)

Max. perm. through drive torque T

439 (595)

- (-)

- (-)

thr

W ith shaft K

T thr

lb.ft (Nm)

W ith shaft S

T thr

lb.ft (Nm)

80 (108)

118 (160)

235 (319)

363 (492)

574 (778)

W ith shaft R

T thr

lb.ft (Nm)

88 (120)

130 (176)

269 (365)

404 (548)

- (-)

Keyed shaft

T thr keyed lb.ft (Nm)

53 (72)

83 (112)

132 (179)

209 (283)

293 (398)

- (-)
411 (557)

T tot = max. permissible input torque pump 1


T thr = max. permissible through drive torque
T thr keyed = max. permissible through drive torque at through drive to keyed shaft
Permissible
overhang
moment
Permissible
overhang
moment

m1 , m2 , m3

weight of pump [lbs (kg)]

l1 , l 2 , l 3

distance to center of gravity [in (mm)]


1
12
1
...
102

T m = (m 1 l 1 + m 2 l 3 + m 3 l 3 )

S iz e

18

28

45

71

Permissible overhang moment Tm

lb.ft (Nm)

369 (500) 649 (880) 1010 (1370) 1593 (2160)

at dyn. acceleration

Tm

lb.ft (Nm)

37 (50)

Weight

lbs (kg)

26,5 (12) 33 (15)

Distance to center of gravity

l1

in (mm)

3.54 (90) 4.33 (110) 5.12 (130)

10g = 98.1 m/s

www.FluiDyneFP.com

65 (88)

[lb.ft]
[Nm]

100

140

2213 (3000) 3319 (4500)

101 (137)

159 (216)

221 (300)

332 (450)

46 (21)

73 (33)

99 (45)

132 (60)

5.91 (150)

6.30 (160)

6.30 (160)

Variable Displacement Pump (A)A10V, Series 31

27

Through Drives
RA 92 711/10.07

| (A)A10VSO

Industrial Hydraulics | Bosch Rexroth AG

27

/36

Through
Drive
Mountingdrive
Options
Overview
of through
mounting options

K02

127-2 (C)

Dimensions of Through Drives


Dimensions of through drives
K01 Flange SAE J744 - 82-2 (A)
Hub for splined shaft to ANSI B.92.1a-1976 5/8 in 9T 16/32 DP

1)

(SAE J744 - 16-4 (A))


Size

section A - B

18

A4

0.57 (14,5)

1.65 (42)

28

8.03 (204)

0.63 (16)

1.85 (47)

45

9.02 (229)

0.63 (16)

2.09 (53)

71

10.51 (267)

0.79 (20)

2.40 (61)

100

13.31 (338)

0.79 (20)

2.56 (65)

13.78 (350)

0.63 (17)

3.03 (77)

140

to pump
mounting
flange
to pump
mounting
flange

A3

7.16 (182)

thread

thread
metric
metric

K52 Flange SAE J744 - 82-2 (A)


28

Hub for
splined shaft to
ANSI(A)A10V,
B.92.1a-1976
3/431in 11T 16/32 DP
Variable
Displacement
Pump
Series

1)

(SAE J744 - 19-4 (A-B))


Size A

section A - B

18

7.16

A2
1.57

www.FluiDyneFP.com
A3

A4

0.74

1.69

A5
M10; 0.57 (14,5) deep

Through Drives

100

13.31 (338)

0.79 (20)

2.56 (65)

140

13.78 (350)

0.63 (17)

3.03 (77)

thread
metric

to pump mounting flange

Dimensions of Through Drives


K52 Flange SAE J744 - 82-2 (A)
Hub for splined shaft to ANSI B.92.1a-1976 3/4 in 11T 16/32 DP

(SAE J744 - 19-4 (A-B))

1)

Size A
section A - B
45

18

A4

28

A3

45

3.2520

DIA3.2508
A 5 (82.55+0.050
+0.020)

9
4.1
DIA 6.5)
0
1
(

71
100

0.39 (10)

A5

to pump mounting flange

A2

thread
metric

A1

140

A2

A3

A4

7.16

1.57

0.74

1.69

(182)

(40)

(18,8)

(43)

8.03

1.53

0.74

1.85

(204)

(39)

(18,8)

(47)

9.02

1.59

0.75

(229)

(40,5) (18,9)

10.51

1.57

0.84

2.40

(267)

(40)

(21,3)

(61)

13.31

1.57

0.75

2.56

(338)

(40)

(19)

(65)

13.78

1.61

0.75

3.03

(350)

(41)

(18,9)

(77)

2.09

A5
M10; 0.57 (14,5) deep
M10; 0.63 (16) deep
M10; 0.63 (16) deep

(53)
M10; 0.79 (20) deep
M10; 0.79 (20) deep
M10; 0.67 (17) deep

K02/K68 Flange SAE J744 - 101-2 (B)


Hub for splined shaft to ANSI B.92.1a-1976 7/8 in 13T 16/32 DP

(SAE J744 - 22-4 (B))

1)

Size A
section A - B
A3

A5

71

A5

+0.050
+0.020

)
46

45

100

A5

.7 5

(101.6

(1

DI

28

A4

DIA 4.0020
4.0008

omitted on
size 28

45

140

0.39 (10)

A2

to pump mounting flange

thread
metric

A1

1)

1)

A2

A3

8.03

1.69

0.70

1.85

(204)

(43)

(17,8)

(47)

45

A4

1.65

0.70

2.09

(229)

(42)

(17,9)

(53)

10.51

1.69

0.80

2.40

(267)

(43)

(20,3) (61)

13.31

1.61

0.71

2.56

(338)

(41)

(18)

(65)

13.78

1.73

0.70

3.03

(350)

(44)

(17,9)

(77)

45
A3

(101,6

+0,050
+0,020
)

4.0020

DIA 4.0008

M12; 0.71 (18) deep


M12; 0.71 (18) deep
M12; 0.79 (20) deep
M12; 0.79 (20) deep
M12; 0.79 (20) deep

(SAE J744 - 25-4 (B-B))

100
140

A5

A5

pressure angle 30 , flat root side fit, tolerance class 5

71
5
5.7
DIA 46)
(1

A4

9.02

Size A
section A - B

A2

A3

A4

9.02

1.87

0.73

2.09

(229)

(47,5)

(18,4)

(53)

10.51

1.87

0.82

2.40

(267)

(47,5) (20,8) (61)

13.31

1.87

0.72

2.56

(338)

(47,5)

(18,2)

(65)

13.78

1.87

0.73

3.03

(350)

(47,5)

(18,4)

(77)

A5
M12; 0.71 (18) deep
M12; 0.79 (20) deep
M12; 0.79 (20) deep
M12; 0.79 (20) deep

0.39 (10)

to pump mounting flange

A1

A2

thread
metric

www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31

K07 Flange SAE J744 - 127-2 (C)


Hub for splined shaft to ANSI B.92.1a-1976 1 1/4 in 14T 12/24 DP

1)

(SAE J744 - 32-4 (C))

29

+0,050

4.0020

DIA 4.0008

100
140

A5

Through Drives

(101,6 +0,020
)

5.
DIA 46)
(1

13.31

1.87

0.72

2.56

(338)

(47,5)

(18,2)

(65)

13.78

1.87

0.73

3.03

(350)

(47,5)

(18,4)

(77)

M12; 0.79 (20) deep


M12; 0.79 (20) deep

0.39 (10)

to pump mounting flange

A1

A2

Dimensions of Through Drives

thread
metric

K07 Flange SAE J744 - 127-2 (C)


Hub for splined shaft to ANSI B.92.1a-1976 1 1/4 in 14T 12/24 DP

1)

(SAE J744 - 32-4 (C))

Size A
section A - B
A5
thread
metric

A3

100

+0.050
+0.020
)

omitted on
size 71
5.0020

7.13
DIA )
1
(18

71

A4

DIA 5.0008

45

140

(127

omitted on
size 71

A2

A3

10.51

2.18

0.87

(267)

(55,5) (22)

(61)

13.31

2.24

0.77

2.56

(338)

(57)

(19,5)

(65)

13.78

2.36

0.77

3.03

(350)

(60)

(19,4)

(77)

A4
2.40

A5
M16; 0.70 (18) deep
M16; 0.95 (24) deep
M16; 0.95 (24) deep

0.51 (13)

to pump mounting flange

A2
A1

K24 Flange SAE J744 - 127-2 (C)


Hub for splined shaft to ANSI B.92.1a-1976 1 1/2 in 17T 12/24 DP

1)

(SAE J744 - 38-4 (C-C))

Size
section A - B

to pump mounting flange

A3

A4

100

13.31 (338)

0.95 (24)

2.56 (65)

140

13.78 (350)

0.95 (34)

3.03 (77)

thread
metric

1)

pressure angle 30 , flat root side fit, tolerance class 5

Dimensions of through drives


K17 Flange SAE J744 - 152-4 (D)
Hub for splined shaft to ANSI B.92.1a-1976 1 3/4 in 13T 8/16 DP
section A - B

to pump mounting flange

30

Variable Displacement Pump (A)A10V, Series 31

1)

(SAE J744 - 44-4 (D))

Size

140

13.78 (350

A3

A4

approx. 0.83 (ca. 21) 3.03 (77)

thread
metric

www.FluiDyneFP.com

Pump Installation Notes


34/36

Bosch Rexroth AG

| Industrial Hydraulics

(A )A10VSO | RA 92 711/10.07

Installation
InstallationNotes
notes
Optional installation position. The pump housing must be filled
with fluid during commissionig and operation.
In order to attain the lowest noise level, all connections
(suction, pressure, pilot, case drain) must be linked by flexible
members to tank.
Avoid placing a check valve in the case drain line.
The case drain hose corresponding to the size of the case
drain port should be installed at the highest case drain port
location.

Vertical installation (shaft end upwards)

Following installation conditions must be taken into account:

=density [kg/m 3 ]
l = pipe lenth [m]
dv/dt = rate of change in fluid velocity[m/s 2 ]
p2 : Pressure lodd due to static head
p2 = h . . g . 10 5 [bar]
h = head [m]
= density [kg/m 3 ]
g = gravity. = 9,81 m/s 2
p3 : line losses (elbows etc.)

Horizontal installation
The pump must be installaed in such a manner, that either L
or L1 is at the top.
Arrangement inside the reservoir

Arrangement inside the reservoir

a) If the min. fluid level is above the top of the pump:

Before installation fill pump housing, keeping it in a horizontal


position.

Close L 1 , "L" and S open, mount suction pipe to port S,


and pipe L at least 200 mm away from suction pipe.

a) If the min. fluid level is equal to or above the pump mounting


surface:

(see. fig. 3)

Close port L, "L 1 " and S open; L 1 piped and also S with
suction pipe (see fig. 1).

Pipe port "L" and "S" acc.to.fig. 4 , port "L 1 " closed.
(compare limiting conditions)

Note: In order to avoid damages to the pump, all attached


parts (e.g. protective caps, covers, etc.) must be removed
before installation.
Fluid

Fluid
L

Arrangement outside the reservoir


Fill pump housing before commissioning.

Limiting condition:
Min. pump inlet pressure p abs min = 12 psi (0,8 bar) under static
and dynamic loading.

Pipe port S and the higher port L or L 1


a) When mounting above the reservoir: see fig. 4 (compare
item limiting conditions)
b) Mounting below the reservoir: pipe ports L and S
according to fig. 5, L closed.

Note: Avoid mounting above tank wherever possible in order to


attain a low noise level.

The permissible suction height h is a result of the overall


pressure loss, but may not be greater than h max = 31.5 in (800
mm) (Immersion depth ht min = 8 in/200 mm).

Fluid

L1

L1

baffle

ht min hmax

B efore installation fill pump housing while keeping it in a


horizontal position. For mounting above the tank see fig. 2.

ht min hmax

fig. 3

S
fig. 1

fig. 4

Fluid
baffle

Fluid

fig. 2

Overall pressure loss


pGes = p1 + p2 + p3 (1 p abs min) = 0,2 bar
p1 : Pressure loss inpipe due to accelerating column of fluid

www.FluiDyneFP.com

L1

Arrangement outside the reservoir

. l . dv . 5
10 [bar]
p1 =
dt

min. 8 in (200mm)

ht min

L1
min. 8 in (200mm)

Note: In order to avoid damages to the pump, all attached


parts (e.g. protective caps, covers, etc.) must be removed
before installation.

ht min

b) If the min. fluid level is below the pump mounting surface:


pipe port L and S acc. to fig. 2, close port L (compare
item limiting conditions)

b)If the min. fluid level is equal to or below the top of the pump:

baffle
L1

S
L

fig. 5

Variable Displacement Pump (A)A10V, Series 31

31

www.FluiDyneFP.com I sales@fluidynefp.com I 586-296-7200

42012

Vous aimerez peut-être aussi