Vous êtes sur la page 1sur 50

Siemens AG 2008

SENTRON Switching
and Protection Devices
Air Circuit Breakers

15/2

Introduction
3WL Air Circuit Breakers

15/5
15/6
15/10
15/14
15/18
15/22
15/28

3WL Air Circuit Breakers/


Non-Automatic Air Circuit Breakers
up to 6300 A (AC)
General data
3-pole, fixed-mounted versions
3-pole, withdrawable versions
4-pole, fixed-mounted versions
4-pole, withdrawable versions
Options
Accessories/spare parts

15/47
15/48
15/49

3WL Non-Automatic Air Circuit Breakers


up to 4000 A (DC)
3- and 4-pole, fixed-mounted versions
3- and 4-pole, withdrawable versions
Accessories/spare parts

Siemens LV 1 2008

Siemens AG 2008

SENTRON Switching and Protection Devices Air Circuit Breakers


Introduction

Overview

Size I

Size III

Size II

Air circuit breakers


3WL air circuit breakers/non-automatic air circuit breakers
up to 6300 A (AC)

3WL non-automatic air circuit breakers


up to 4000 A (DC)

Size

I, II, III

II

630, 800, 1000, 1250,


1600, 2000, 2500, 3200, 4000,
5000, 6300

1000, 2000, 4000

3-pole, 4-pole

3-pole, 4-pole

Rated operational
voltage Ue

V AC
V DC

Up to 690/1000
--

-Up to 1000

Rated ultimate
short-circuit breaking
capacity at 500 V AC

kA

Rated current In

Number of poles

Endurance

Size I

Size II

Size III

55/66

66/80/100

100/150 (3-pole),
130 (4-pole)

30/25/20
(at 300/600/1000 V DC)

15000

10000

15000

Operating 20000
cycles

Mounting position

15

3 0

3 0

3 0

N S E 0 _ 0 0 0 6 1

Degree of protection
With cover
Without cover
(with door sealing frame)

3 0

3 0

3 0

3 0

N S E 0 _ 0 0 0 6 1

N S E 0 _ 0 0 0 6 2

IP55
IP41

3 0

N S E 0 _ 0 0 0 6 2

IP55
IP41

Dimensions 3-/4-pole
T

NSS0_00535

W mm
Fixed mounting H mm
D mm
Withdrawable H mm
D mm

320/410

460/590

704/914

460/590

434
291

434
291

434
291

434
291

465.5
471

465.5
471

465.5
471

465.5
471

ETU27B

ETU45B

cs

cw

ETU55B

Rating Plug

NSE0_01111a

ETU25B

OFF :

NSE0_01110b

NSE0_01108a

ETU15B

NSE0_01109a

NSE0_01107a

Type

NSE0_01106a

Rating Plug

ETU76B

Electronic trip units for SENTRON 3WL circuit breakers


Overload protection

Short-time delayed
short-circuit protection

--

Instantaneous
short-circuit protection

Neutral conductor protection

--

--

Ground-fault protection

--

--

Zone Selective Interlocking

--

--

--

LCD, 4-line

--

--

--

--

--

LCD, graphic

--

--

--

--

--

Communication through
PROFIBUS DP

--

--

--

Measurement function Plus

--

--

--

Selectable parameter sets

--

--

--

--

Parameters freely programmable

--

--

--

--

CubicleBUS

--

--

--

Standard
-- Not available
Optional

15/2

Siemens LV 1 2008

ECO switching capacity N


Standard switching capacity S
High switching capacity H
Very high switching capacity C
DC switching capacity

3WL air circuit breakers/non-automatic air circuit


breakers according to UL 489 up to 5000 A,
see Catalog LV 16.

Siemens AG 2008

SENTRON Switching and Protection Devices Air Circuit Breakers


Introduction

Communication-capable circuit breakers

1 SENTRON 3VL
2 LCD ETU release

19

3 COM10 PROFIBUS

module including ZSI

4 Breaker Data Adapter

(BDA)
5 BDA Plus with Ethernet

interface

9
10
11
12
13
14
15
16
17
18
19

17
18

1) For MODBUS Win PM, Net on PC.

Features
Coordinated communication concept using the PROFIBUS DP
or MODBUS, ranging from 16 A to 6300 A with SENTRON 3VL
and SENTRON 3WL
The high level of modularity of circuit breakers and accessories
allows easy retrofitting of all communication components
Significant additional benefits for the switchboard due to the
possibility of linking up external input and output modules to
the circuit breaker-internal CubicleBUS of the SENTRON 3WL

12

13

14

15

16

4
8
9
1

15

7
8

and output device


(e.g. notebook)
SENTRON 3WL
COM15 PROFIBUS
module or COM16
MODBUS module
Breaker Status Sensor
(BSS)
Electronic release ETU
Metering function Plus
ZSI module
Digital output module
as relay
Digital output module
as relay, configurable
Analog output module
Digital input module
Switch ES Power on PC 1)
PLC e.g. SIMATIC S7
SIMATIC powercontrol

10
11

NSE0_01105f

6 Browser-capable input

Innovative software products for parameterization, operation,


monitoring, and diagnostics of SENTRON circuit breakers, both
locally or via PROFIBUS DP, MODBUS or Ethernet/Intranet/Internet
Complete integration of the SENTRON circuit breakers into the
Totally Integrated Power and Totally Integrated Automation
solutions

Siemens LV 1 2008

15/3

Siemens AG 2008

SENTRON Switching and Protection Devices Air Circuit Breakers


Introduction
SENTRON 3WL:
Superior individual products integrated into uniform power
distribution systems - up to and including industry-specific
industrial and infrastructure solutions

6
7

8
5

9
1

15

25

21

10

19
22

11

23
12

24

18

13

14
20

16
15

$
%

Guide frames (pages 15/29 and 15/30)

&
(
)
*
+
,
.
/
0
1

Position indicator switches (pages 15/25 and 15/35)

Main circuit connection front, flange, horizontal, vertical


(pages 15/42 and 15/43)
Grounding contact, leading (page 15/39)
Shutters (page 15/38)
COM15 PROFIBUS modules or COM16 MODBUS modules (page 15/41)
External CubicleBUS modules (page 15/40)
Closing solenoids, auxiliary trip units (page 15/37)
Auxiliary conductor plug-in systems (page 15/36)
Auxiliary switch blocks (page 15/37)
Door sealing frames (page 15/38)
Interlocking sets for base plate (page 15/33)
Transparent panels, function insert (page 15/32)

15/4

Siemens LV 1 2008

2
3
4
5
6

EMERGENCY-STOP pushbuttons, key operated (page 15/35)

7
8
9
:
;
<
=

Remote reset solenoids (page 15/32)

Motorized operating mechanisms (page 15/37)


Operating cycles counters (page 15/35)
Breaker status sensors (BSS) (page 15/41)
Protective devices with device holder, electronic trip units (ETU)
(page 15/31)
Breaker data adapters (BDA) (page 15/40)
Four-line displays (page 15/31)
Ground-fault protection modules (page 15/31)
Rated current modules (page 15/31)
Measuring function modules (page 15/31)
Circuit breakers (pages 15/6 to 15/21)

NSE0_01887

17

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


General data

Low space requirements


The SENTRON 3WL devices require very little space. Size I devices
(up to 1600 A) fit into a 400 mm wide switchgear panel. Size III
devices (up to 6300 A) are the smallest of their kind and with their
construction width of 704 mm fit into a 800 mm wide switchgear
panel.
Modular design
Components like auxiliary trip units, motorized operating
mechanisms, electronic trip units, current sensors, auxiliary
circuit signaling switches, automatic reset devices, interlocks
and engagement operating mechanisms can all be exchanged
or retrofitted at a later stage, thus allowing the circuit breaker to
be adapted to new, changing requirements.
The main contact elements can all be replaced in order to increase
the endurance of the circuit breaker.
Retrofittable modules for electronic trip units
Modularity is one of the main features of the new SENTRON 3WL
circuit breakers.
Special LCDs, ground-fault modules, rated current modules and
communications modules for the electronic trip units are available
for fast and easy retrofitting and adaptation to changing
requirements.
Communication
The use of modern communication-capable circuit breakers opens
up completely new possibilities in terms of start-up, parameterization,
diagnostics, maintenance and operation. This allows many different
ways of reducing costs and improving productivity in industrial
plants, buildings and infrastructure projects to be achieved.
Fast and reliable parameterization
Timely information and response can prevent plant
stoppages
Effective diagnostics management
Measured values are the basis for efficient load management,
for drawing up power demand profiles and for assigning energy
to cost centers
Preventive maintenance reduces the risk of expansive plant
down-times

Application
As incoming-feeder, distribution, tie, and outgoing-feeder
circuit breakers in electrical installations
For switching and protecting motors, capacitors, generators,
transformers, busbars and cables
Due to the reinforced use of electronic control systems, the demands
made on air circuit breakers in terms of operator control and
monitoring of network processes have increased.
The extensive, coordinated SENTRON range of devices covers
all applications between 16 A and 6300 A with compact and air
circuit breakers.
The AC devices are available as circuit breakers and non-automatic
air circuit breakers. DC devices are only available as non-automatic
air circuit breakers.
Switching capacity
The circuit breakers with ECO switching capacity N
(Icu up to 55/66 kA at 500 V) are indicated in the selection
and ordering data by green backgrounds.
The circuit breakers with standard switching capacity S
(Icu up to 66/80 kA at 500 V) are indicated in the selection
and ordering data by blue backgrounds.
The circuit breakers with high switching capacity H
(Icu up to 100 kA at 500 V) are indicated in the selection and
ordering data by orange backgrounds.
The circuit breakers with very high switching capacity C
(Icu up to 150 kA (3-pole)/130 kA (4-pole) at 500 V) are
indicated in the selection and ordering data by dark-orange
backgrounds.
The circuit breakers for direct current are indicated in the
selection and ordering data by yellow backgrounds.

Standards
SENTRON 3WL circuit breakers comply with:
IEC 60947-2
DIN VDE 0660 Part 101
Climate-proof to DIN IEC 68 Part 30-2
Versions with UL 489 also available, see Catalog LV 16.
For further standards, see Appendix.

Siemens LV 1 2008

15/5

15

Benefits

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, fixed-mounted versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
For Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@32-....
3WL11 08-2@@32-....
3WL11 10-2@@32-....
3WL11 12-2@@32-....
3WL11 16-2@@32-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@32-....
3WL12 10-2@@32-....
3WL12 12-2@@32-....
3WL12 16-2@@32-....
3WL12 20-2@@32-....
3WL12 25-2@@32-....
3WL12 32-2@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

15

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@31-....
3WL11 08-2@@31-....
3WL11 10-2@@31-....
3WL11 12-2@@31-....
3WL11 16-2@@31-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@31-....
3WL12 10-2@@31-....
3WL12 12-2@@31-....
3WL12 16-2@@31-....
3WL12 20-2@@31-....
3WL12 25-2@@31-....
3WL12 32-2@@31-....
3WL12 40-2@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@33-....
3WL11 08-2@@33-....
3WL11 10-2@@33-....
3WL11 12-2@@33-....
3WL11 16-2@@33-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@33-....
3WL12 10-2@@33-....
3WL12 12-2@@33-....
3WL12 16-2@@33-....
3WL12 20-2@@33-....
3WL12 25-2@@33-....
3WL12 32-2@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@34-....
3WL11 08-2@@34-....
3WL11 10-2@@34-....
3WL11 12-2@@34-....
3WL11 16-2@@34-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@34-....
3WL12 10-2@@34-....
3WL12 12-2@@34-....
3WL12 16-2@@34-....
3WL12 20-2@@34-....
3WL12 25-2@@34-....
3WL12 32-2@@34-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Non-automatic air circuit breakers2)


without electronic trip unit

Order No. supplements


AA

Add. price
without

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/9.

15/6

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V, standard switching


capacity S

kA

DT

Order No.
For Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
SET,
M)
Basic price
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@32-....
3WL11 08-3@@32-....
3WL11 10-3@@32-....
3WL11 12-3@@32-....
3WL11 16-3@@32-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@32-....
3WL12 10-3@@32-....
3WL12 12-3@@32-....
3WL12 16-3@@32-....
3WL12 20-3@@32-....
3WL12 25-3@@32-....
3WL12 32-3@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@31-....
3WL11 08-3@@31-....
3WL11 10-3@@31-....
3WL11 12-3@@31-....
3WL11 16-3@@31-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@31-....
3WL12 10-3@@31-....
3WL12 12-3@@31-....
3WL12 16-3@@31-....
3WL12 20-3@@31-....
3WL12 25-3@@31-....
3WL12 32-3@@31-....
3WL12 40-3@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@33-....
3WL11 08-3@@33-....
3WL11 10-3@@33-....
3WL11 12-3@@33-....
3WL11 16-3@@33-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@33-....
3WL12 10-3@@33-....
3WL12 12-3@@33-....
3WL12 16-3@@33-....
3WL12 20-3@@33-....
3WL12 25-3@@33-....
3WL12 32-3@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@34-....
3WL11 08-3@@34-....
3WL11 10-3@@34-....
3WL11 12-3@@34-....
3WL11 16-3@@34-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@34-....
3WL12 10-3@@34-....
3WL12 12-3@@34-....
3WL12 16-3@@34-....
3WL12 20-3@@34-....
3WL12 25-3@@34-....
3WL12 32-3@@34-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/9.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/7

15

Vertical main circuit connection


I
I
I
I
I

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@32-....
3WL12 10-4@@32-....
3WL12 12-4@@32-....
3WL12 16-4@@32-....
3WL12 20-4@@32-....
3WL12 25-4@@32-....
3WL12 32-4@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@32-....
3WL13 50-4@@32-....

1
1

1 unit
1 unit

103
103

82.000
82.000

Vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@31-....
3WL12 10-4@@31-....
3WL12 12-4@@31-....
3WL12 16-4@@31-....
3WL12 20-4@@31-....
3WL12 25-4@@31-....
3WL12 32-4@@31-....
3WL12 40-4@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@31-....
3WL13 50-4@@31-....
3WL13 63-4@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

82.000
82.000
82.000

15

Front main circuit connection, single hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@33-....
3WL12 10-4@@33-....
3WL12 12-4@@33-....
3WL12 16-4@@33-....
3WL12 20-4@@33-....
3WL12 25-4@@33-....
3WL12 32-4@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

III

4000

4000

100 B

3WL13 40-4@@33-....

1 unit

103

82.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

1 unit

103

82.000

Front main circuit connection, double hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@34-....
3WL12 10-4@@34-....
3WL12 12-4@@34-....
3WL12 16-4@@34-....
3WL12 20-4@@34-....
3WL12 25-4@@34-....
3WL12 32-4@@34-....

III

4000

4000

100 B

3WL13 40-4@@34-....

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/9.

15/8

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 150 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


III
III

4000
5000

4000
5000

150 B
150 B

3WL13 40-5@@32-....
3WL13 50-5@@32-....

1
1

1 unit
1 unit

103
103

82.000
82.000

4000
5000
6300

150 B
150 B
150 B

3WL13 40-5@@31-....
3WL13 50-5@@31-....
3WL13 63-5@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

82.000
82.000
90.000

Vertical main circuit connection


III
III
III

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Manual operating mechanism with mechanical closing


Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

1AA2

2)

The rated current is determined by the rated current module. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on
page 15/23.
For permissible rated short-time current Icc and rated short-circuit
making capacity Icm for non-automatic air circuit breakers see
Technical Information LV 1T, "Technical specifications".

* You can order this quantity or a multiple thereof.

without

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 15/31.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 15/31.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT


(alarm and tripping), see page 15/31.

Footnotes for pages 15/6 to 15/9:


1)

15

Standard Order No. supplements (for further Order No. supplements, see page 15/22)

Siemens LV 1 2008

15/9

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
For Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@35-....
3WL11 08-2@@35-....
3WL11 10-2@@35-....
3WL11 12-2@@35-....
3WL11 16-2@@35-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

45.000
45.000
45.000
45.000
45.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@35-....
3WL12 10-2@@35-....
3WL12 12-2@@35-....
3WL12 16-2@@35-....
3WL12 20-2@@35-....
3WL12 25-2@@35-....
3WL12 32-2@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000
70.000
70.000
70.000
70.000
70.000

15

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@36-....
3WL11 08-2@@36-....
3WL11 10-2@@36-....
3WL11 12-2@@36-....
3WL11 16-2@@36-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@36-....
3WL12 10-2@@36-....
3WL12 12-2@@36-....
3WL12 16-2@@36-....
3WL12 20-2@@36-....
3WL12 25-2@@36-....
3WL12 32-2@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@37-....
3WL11 08-2@@37-....
3WL11 10-2@@37-....
3WL11 12-2@@37-....
3WL11 16-2@@37-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@37-....
3WL12 10-2@@37-....
3WL12 12-2@@37-....
3WL12 16-2@@37-....
3WL12 20-2@@37-....
3WL12 25-2@@37-....
3WL12 32-2@@37-....
3WL12 40-2@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000
103 121.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@38-....
3WL11 08-2@@38-....
3WL11 10-2@@38-....
3WL11 12-2@@38-....
3WL11 16-2@@38-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@38-....
3WL12 10-2@@38-....
3WL12 12-2@@38-....
3WL12 16-2@@38-....
3WL12 20-2@@38-....
3WL12 25-2@@38-....
3WL12 32-2@@38-....
Order No. supplements
AA

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

Non-automatic air circuit breakers2)


Without electronic trip unit

70.000
70.000
70.000
70.000
70.000

Add. price
without

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

15/10

Siemens LV 1 2008

1AA2

without

For footnotes see page 15/13.

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
For Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@35-....
3WL11 08-3@@35-....
3WL11 10-3@@35-....
3WL11 12-3@@35-....
3WL11 16-3@@35-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

45.000
45.000
45.000
45.000
45.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@35-....
3WL12 10-3@@35-....
3WL12 12-3@@35-....
3WL12 16-3@@35-....
3WL12 20-3@@35-....
3WL12 25-3@@35-....
3WL12 32-3@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000
70.000
70.000
70.000
70.000
70.000

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@36-....
3WL11 08-3@@36-....
3WL11 10-3@@36-....
3WL11 12-3@@36-....
3WL11 16-3@@36-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@36-....
3WL12 10-3@@36-....
3WL12 12-3@@36-....
3WL12 16-3@@36-....
3WL12 20-3@@36-....
3WL12 25-3@@36-....
3WL12 32-3@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@37-....
3WL11 08-3@@37-....
3WL11 10-3@@37-....
3WL11 12-3@@37-....
3WL11 16-3@@37-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@37-....
3WL12 10-3@@37-....
3WL12 12-3@@37-....
3WL12 16-3@@37-....
3WL12 20-3@@37-....
3WL12 25-3@@37-....
3WL12 32-3@@37-....
3WL12 40-3@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000
103 121.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@38-....
3WL11 08-3@@38-....
3WL11 10-3@@38-....
3WL11 12-3@@38-....
3WL11 16-3@@38-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@38-....
3WL12 10-3@@38-....
3WL12 12-3@@38-....
3WL12 16-3@@38-....
3WL12 20-3@@38-....
3WL12 25-3@@38-....
3WL12 32-3@@38-....
Order No. supplements
AA

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

Non-automatic air circuit breakers2)


Without electronic trip unit

70.000
70.000
70.000
70.000
70.000

Add. price
without

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/13.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/11

15

With guide frames, horizontal main circuit connection


I
I
I
I
I

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@35-....
3WL12 10-4@@35-....
3WL12 12-4@@35-....
3WL12 16-4@@35-....
3WL12 20-4@@35-....
3WL12 25-4@@35-....
3WL12 32-4@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@35-....
3WL13 50-4@@35-....
3WL13 63-4@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

88.000
88.000
96.000

With guide frames, horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@36-....
3WL12 10-4@@36-....
3WL12 12-4@@36-....
3WL12 16-4@@36-....
3WL12 20-4@@36-....
3WL12 25-4@@36-....
3WL12 32-4@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@36-....
3WL13 50-4@@36-....

1
1

1 unit
1 unit

103 148.000
103 148.000

15

With guide frames, vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@37-....
3WL12 10-4@@37-....
3WL12 12-4@@37-....
3WL12 16-4@@37-....
3WL12 20-4@@37-....
3WL12 25-4@@37-....
3WL12 32-4@@37-....
3WL12 40-4@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000
103 121.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@37-....
3WL13 50-4@@37-....
3WL13 63-4@@37-....

1
1
1

1 unit
1 unit
1 unit

103 148.000
103 148.000
103 166.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 91.000
103 91.000
103 91.000
103 91.000
103 91.000
103 102.000
103 113.000

1 unit

103 148.000

With guide frames, connecting flanges


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@38-....
3WL12 10-4@@38-....
3WL12 12-4@@38-....
3WL12 16-4@@38-....
3WL12 20-4@@38-....
3WL12 25-4@@38-....
3WL12 32-4@@38-....

III

4000

4000

100 B

3WL13 40-4@@38-....

Non-automatic air circuit breakers 2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/13.

15/12

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 150 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
III
III
III

4000
5000
6300

4000
5000
6300

150 B
150 B
150 B

3WL13 40-5@@35-....
3WL13 50-5@@35-....
3WL13 63-5@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

88.000
88.000
96.000

150 B
150 B

3WL13 40-5@@36-....
3WL13 50-5@@36-....

1
1

1 unit
1 unit

103 148.000
103 148.000

150 B
150 B
150 B

3WL13 40-5@@37-....
3WL13 50-5@@37-....
3WL13 63-5@@37-....

1
1
1

1 unit
1 unit
1 unit

103 148.000
103 148.000
103 166.000

With guide frames, horizontal main circuit connection


III
III

4000
5000

4000
5000

With guide frames, vertical main circuit connection


III
III
III

4000
5000
6300

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

Add. price
without

AA

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

15

Electronic trip units

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

1AA2
3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 15/31.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 15/31.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT


(alarm and tripping), see page 15/31.

Footnotes for pages 15/10 to 15/13:


1)

2)

The rated current is determined by the rated current module. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 15/23.
For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see Technical Information
LV 1T, "Technical specifications".

* You can order this quantity or a multiple thereof.

without

Siemens LV 1 2008

15/13

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, fixed-mounted versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@42-....
3WL11 08-2@@42-....
3WL11 10-2@@42-....
3WL11 12-2@@42-....
3WL11 16-2@@42-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@42-....
3WL12 10-2@@42-....
3WL12 12-2@@42-....
3WL12 16-2@@42-....
3WL12 20-2@@42-....
3WL12 25-2@@42-....
3WL12 32-2@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000
50.000
50.000
50.000
50.000
50.000

15

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@41-....
3WL11 08-2@@41-....
3WL11 10-2@@41-....
3WL11 12-2@@41-....
3WL11 16-2@@41-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@41-....
3WL12 10-2@@41-....
3WL12 12-2@@41-....
3WL12 16-2@@41-....
3WL12 20-2@@41-....
3WL12 25-2@@41-....
3WL12 32-2@@41-....
3WL12 40-2@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 75.000
103 75.000
103 75.000
103 75.000
103 75.000
103 71.000
103 77.000
103 103.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@43-....
3WL11 08-2@@43-....
3WL11 10-2@@43-....
3WL11 12-2@@43-....
3WL11 16-2@@43-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@43-....
3WL12 10-2@@43-....
3WL12 12-2@@43-....
3WL12 16-2@@43-....
3WL12 20-2@@43-....
3WL12 25-2@@43-....
3WL12 32-2@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@44-....
3WL11 08-2@@44-....
3WL11 10-2@@44-....
3WL11 12-2@@44-....
3WL11 16-2@@44-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@44-....
3WL12 10-2@@44-....
3WL12 12-2@@44-....
3WL12 16-2@@44-....
3WL12 20-2@@44-....
3WL12 25-2@@44-....
3WL12 32-2@@44-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/17.

15/14

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@42-....
3WL11 08-3@@42-....
3WL11 10-3@@42-....
3WL11 12-3@@42-....
3WL11 16-3@@42-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@42-....
3WL12 10-3@@42-....
3WL12 12-3@@42-....
3WL12 16-3@@42-....
3WL12 20-3@@42-....
3WL12 25-3@@42-....
3WL12 32-3@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000
50.000
50.000
50.000
50.000
50.000

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@41-....
3WL11 08-3@@41-....
3WL11 10-3@@41-....
3WL11 12-3@@41-....
3WL11 16-3@@41-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@41-....
3WL12 10-3@@41-....
3WL12 12-3@@41-....
3WL12 16-3@@41-....
3WL12 20-3@@41-....
3WL12 25-3@@41-....
3WL12 32-3@@41-....
3WL12 40-3@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 75.000
103 75.000
103 75.000
103 67.000
103 75.000
103 71.000
103 77.000
103 103.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@43-....
3WL11 08-3@@43-....
3WL11 10-3@@43-....
3WL11 12-3@@43-....
3WL11 16-3@@43-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@43-....
3WL12 10-3@@43-....
3WL12 12-3@@43-....
3WL12 16-3@@43-....
3WL12 20-3@@43-....
3WL12 25-3@@43-....
3WL12 32-3@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@44-....
3WL11 08-3@@44-....
3WL11 10-3@@44-....
3WL11 12-3@@44-....
3WL11 16-3@@44-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@44-....
3WL12 10-3@@44-....
3WL12 12-3@@44-....
3WL12 16-3@@44-....
3WL12 20-3@@44-....
3WL12 25-3@@44-....
3WL12 32-3@@44-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/17.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/15

15

Vertical main circuit connection


I
I
I
I
I

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@42-....
3WL12 10-4@@42-....
3WL12 12-4@@42-....
3WL12 16-4@@42-....
3WL12 20-4@@42-....
3WL12 25-4@@42-....
3WL12 32-4@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@42-....
3WL13 50-4@@42-....

1
1

1 unit
1 unit

103 106.000
103 99.000

Vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@41-....
3WL12 10-4@@41-....
3WL12 12-4@@41-....
3WL12 16-4@@41-....
3WL12 20-4@@41-....
3WL12 25-4@@41-....
3WL12 32-4@@41-....
3WL12 40-4@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 75.000
103 75.000
103 67.000
103 67.000
103 75.000
103 71.000
103 77.000
103 103.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@41-....
3WL13 50-4@@41-....
3WL13 63-4@@41-....

1
1
1

1 unit
1 unit
1 unit

103 106.000
103 99.000
103 106.000

15

Front main circuit connection, single hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@43-....
3WL12 10-4@@43-....
3WL12 12-4@@43-....
3WL12 16-4@@43-....
3WL12 20-4@@43-....
3WL12 25-4@@43-....
3WL12 32-4@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

III

4000

4000

100 B

3WL13 40-4@@43-....

1 unit

103

99.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

1 unit

103 106.000

Front main circuit connection, double hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@44-....
3WL12 10-4@@44-....
3WL12 12-4@@44-....
3WL12 16-4@@44-....
3WL12 20-4@@44-....
3WL12 25-4@@44-....
3WL12 32-4@@44-....

III

4000

4000

100 B

3WL13 40-4@@44-....

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page15/17.

15/16

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 130 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


III
III

4000
5000

4000
5000

130 B
130 B

3WL13 40-5@@42-....
3WL13 50-5@@42-....

1
1

1 unit
1 unit

103
103

99.000
99.000

4000
5000
6300

130 B
130 B
130 B

3WL13 40-5@@41-....
3WL13 50-5@@41-....
3WL13 63-5@@41-....

1
1
1

1 unit
1 unit
1 unit

103 99.000
103 99.000
103 108.000

Vertical main circuit connection


III
III
III

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Manual operating mechanism with mechanical closing


Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

1AA2

The rated current is determined by the rated current module. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 15/23.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see Technical Information
LV 1T, "Technical specifications".

* You can order this quantity or a multiple thereof.

without

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 15/31.
The internal transformers for N conductors can be ordered by adding the
supplement "Z" and the order code "F23", see page 15/25.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 15/31.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT


(alarm and tripping), see page 15/31.

Footnotes for pages 15/14 to 15/17:


1)

15

Standard Order No. supplements (for further Order No. supplements, see page 15/22)

Siemens LV 1 2008

15/17

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


current
In
In max.
A

Icu up to 55/66 kA at 500 V,


ECO switching capacity N
Order No.
Order No. supplements,
kA DT see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@45-....
3WL11 08-2@@45-....
3WL11 10-2@@45-....
3WL11 12-2@@45-....
3WL11 16-2@@45-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

54.000
54.000
54.000
54.000
54.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@45-....
3WL12 10-2@@45-....
3WL12 12-2@@45-....
3WL12 16-2@@45-....
3WL12 20-2@@45-....
3WL12 25-2@@45-....
3WL12 32-2@@45-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

75.000
75.000
75.000
75.000
75.000
76.000
82.000

15

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@46-....
3WL11 08-2@@46-....
3WL11 10-2@@46-....
3WL11 12-2@@46-....
3WL11 16-2@@46-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@46-....
3WL12 10-2@@46-....
3WL12 12-2@@46-....
3WL12 16-2@@46-....
3WL12 20-2@@46-....
3WL12 25-2@@46-....
3WL12 32-2@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@47-....
3WL11 08-2@@47-....
3WL11 10-2@@47-....
3WL11 12-2@@47-....
3WL11 16-2@@47-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@47-....
3WL12 10-2@@47-....
3WL12 12-2@@47-....
3WL12 16-2@@47-....
3WL12 20-2@@47-....
3WL12 25-2@@47-....
3WL12 32-2@@47-....
3WL12 40-2@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@48-....
3WL11 08-2@@48-....
3WL11 10-2@@48-....
3WL11 12-2@@48-....
3WL11 16-2@@48-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@48-....
3WL12 10-2@@48-....
3WL12 12-2@@48-....
3WL12 16-2@@48-....
3WL12 20-2@@48-....
3WL12 25-2@@48-....
3WL12 32-2@@48-....
Order No. supplements
AA

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

Non-automatic air circuit breakers2)


Without electronic trip unit

Add. price
without

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

15/18

Siemens LV 1 2008

1AA2

without

For footnotes see page 15/21.

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@45-....
3WL11 08-3@@45-....
3WL11 10-3@@45-....
3WL11 12-3@@45-....
3WL11 16-3@@45-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

54.000
54.000
54.000
54.000
54.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@45-....
3WL12 10-3@@45-....
3WL12 12-3@@45-....
3WL12 16-3@@45-....
3WL12 20-3@@45-....
3WL12 25-3@@45-....
3WL12 32-3@@45-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

75.000
75.000
75.000
75.000
75.000
76.000
82.000

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@46-....
3WL11 08-3@@46-....
3WL11 10-3@@46-....
3WL11 12-3@@46-....
3WL11 16-3@@46-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@46-....
3WL12 10-3@@46-....
3WL12 12-3@@46-....
3WL12 16-3@@46-....
3WL12 20-3@@46-....
3WL12 25-3@@46-....
3WL12 32-3@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@47-....
3WL11 08-3@@47-....
3WL11 10-3@@47-....
3WL11 12-3@@47-....
3WL11 16-3@@47-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@47-....
3WL12 10-3@@47-....
3WL12 12-3@@47-....
3WL12 16-3@@47-....
3WL12 20-3@@47-....
3WL12 25-3@@47-....
3WL12 32-3@@47-....
3WL12 40-3@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@48-....
3WL11 08-3@@48-....
3WL11 10-3@@48-....
3WL11 12-3@@48-....
3WL11 16-3@@48-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@48-....
3WL12 10-3@@48-....
3WL12 12-3@@48-....
3WL12 16-3@@48-....
3WL12 20-3@@48-....
3WL12 25-3@@48-....
3WL12 32-3@@48-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements


AA

Add. price
without

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/21.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/19

15

With guide frames, horizontal main circuit connection


I
I
I
I
I

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 15/22

PS*
PU
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@45-....
3WL12 10-4@@45-....
3WL12 12-4@@45-....
3WL12 16-4@@45-....
3WL12 20-4@@45-....
3WL12 25-4@@45-....
3WL12 32-4@@45-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

72.000
72.000
75.000
75.000
75.000
76.000
82.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@45-....
3WL13 50-4@@45-....
3WL13 63-4@@45-....

1
1
1

1 unit
1 unit
1 unit

103 106.000
103 106.000
103 108.000

With guide frames, horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@46-....
3WL12 10-4@@46-....
3WL12 12-4@@46-....
3WL12 16-4@@46-....
3WL12 20-4@@46-....
3WL12 25-4@@46-....
3WL12 32-4@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@46-....
3WL13 50-4@@46-....

1
1

1 unit
1 unit

103 190.000
103 190.000

15

With guide frames, vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@47-....
3WL12 10-4@@47-....
3WL12 12-4@@47-....
3WL12 16-4@@47-....
3WL12 20-4@@47-....
3WL12 25-4@@47-....
3WL12 32-4@@47-....
3WL12 40-4@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@47-....
3WL13 50-4@@47-....
3WL13 63-4@@47-....

1
1
1

1 unit
1 unit
1 unit

103 190.000
103 190.000
103 227.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

1 unit

103 190.000

With guide frames, connecting flanges


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@48-....
3WL12 10-4@@48-....
3WL12 12-4@@48-....
3WL12 16-4@@48-....
3WL12 20-4@@48-....
3WL12 25-4@@48-....
3WL12 32-4@@48-....

III

4000

4000

100 B

3WL13 40-4@@48-....

Non-automatic air circuit breakers2)


Without electronic trip unit

Order No. supplements

109.000
109.000
109.000
109.000
109.000
123.000
136.000

Add. price
without

AA

Electronic trip units


Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO

1AA2

without

x = additional price
For footnotes see page 15/21.

15/20

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 130 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 15/22

PU
PS*
(UNIT,
Basic price SET, M)
per PU

PG

Weight
per PU
approx.
kg

Without guide frames


(for guide frames, see page 15/29 and 15/30)
III
III
III

4000
5000
6300

4000
5000
6300

130 B
130 B
130 B

3WL13 40-5@@45-....
3WL13 50-5@@45-....
3WL13 63-5@@45-....

1
1
1

1 unit
1 unit
1 unit

103 115.000
103 115.000
103 108.000

130 B
130 B

3WL13 40-5@@46-....
3WL13 50-5@@46-....

1
1

1 unit
1 unit

103 190.000
103 190.000

130 B
130 B
130 B

3WL13 40-5@@47-....
3WL13 50-5@@47-....
3WL13 63-5@@47-....

1
1
1

1 unit
1 unit
1 unit

103 190.000
103 190.000
103 227.000

With guide frames, horizontal main circuit connection


III
III

4000
5000

4000
5000

With guide frames, vertical main circuit connection


III
III
III

4000
5000
6300

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

Add. price
without

AA

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU55B: Protection functions LSIN3)
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
JB
NB

x
x
x
x
x
x

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU55B: Protection functions LSING3)5)
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
JG
NG

x
x
x
x
x

15

Electronic trip units

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary trip units; auxiliary switch 2 NC + 2 NO
x = additional price

1AA2

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 15/31.
The internal transformers for N conductors can be ordered by adding the
supplement "Z" and the order code "F23", see page 15/25.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 15/31.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT


(alarm and tripping), see page 15/31.

Footnotes for pages 15/18 to 15/21:


1)

The rated current is determined by the rated current module. For the standard
version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 15/23.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see Technical Information
LV 1T, "Technical specifications".

* You can order this quantity or a multiple thereof.

without

3)

Siemens LV 1 2008

15/21

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options

Selection and ordering data


Order No. supplement

Add. price

3WL 1. . . - . . . . . -7 7 7 7

Operating mechanisms
Manual operating mechanism with mechanical closing

without

2
3

x
x

4
5
6

x
x
x

Manual operating mechanism with mechanical


and electrical closing,
closing solenoid suitable for continuous duty, 100 % ON period
Closing solenoid
AC 50/60 Hz V

V DC

110
230

110 ... 125


220

Manual/motorized operating mechanism with mechanical


and electrical closing,
closing solenoid suitable for continuous duty, 100 % ON period
Motor

Closing solenoid

AC 50/60 Hz V

V DC

AC 50/60 Hz V

V DC

208 ... 240


110 ... 127
--

220 ... 250


110 ... 125
24

230
110
--

220
110 ... 125
24

To order different voltages for motorized operating mechanism and


closing solenoid:
"1" at the 13th digit of the Order No. and order codes, see page 15/24.

1st auxiliary trip unit

15

Without 1st auxiliary trip unit

without

B
C
D
E
F
G

x
x
x
x
x
x

Shunt trip unit suitable for continuous duty, 100 % ON period


Operating range 0.85 ... 1.1 x Us

Us AC 50/60 Hz V Us V DC
----110
230

24
30
48
60
110 ... 125
220

2nd auxiliary trip unit


Without 2nd auxiliary trip unit

without

B
C
D
E
F
G

x
x
x
x
x
x

J
K
L
U
M
N
P

x
x
x
x
x
x
x

Q
R
S
T

x
x
x
x

Shunt trip unit suitable for continuous duty, 100 % ON period


Operating range 0.85 ... 1.1 x Us

Us AC 50/60 Hz V Us V DC
-24
-30
-48
-60
110
110 ... 125
230
220
Undervoltage trip unit, instantaneous ( 80 ms),
short-delay ( 200 ms)
Operating range 0.85 ... 1.1 x Us

Us AC 50/60 Hz V Us V DC
-24
-30
-48
-60
110 ... 127
110 ... 125
208 ... 240
220 ... 250
380 ... 415
-Undervoltage trip unit, can be delayed between 0.2 s and 3.2 s
Operating range 0.85 ... 1.1 x Us

Us AC 50/60 Hz V Us V DC
-48
110 ... 127
110 ... 125
208 ... 240
220 ... 250
380 ... 415
--

Auxiliary switches
1st auxiliary switch block
2 NO + 2 NC

without

1st + 2nd auxiliary switch block


4 NO + 4 NC
6 NO + 2 NC
5 NO + 3 NC

4
7
8

x
x
x

x = additional price

15/22

Siemens LV 1 2008

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1 2 3 4 5

6 7

Add. price

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
+. . . + . . .
@@@
Code for
"Further versions"Z

Operator's guide
Printed version
In scope of supply of circuit breaker) French/Italian

A 1 1

In scope of supply of circuit breaker) Spanish/Portuguese

A 1 2

Rated voltage 1000 V AC/DC


Only for circuit breakers with high switching capacity H
(8th digit of the Order No. is a "4")

Add.
price
3-pole

Add.
price
4-pole

Size II4)

up to 2000 A
up to 2500 A
up to 3200 A

A 0 5
A 0 5
A 0 5

x
x
x

x
x
x

Size III4)5)

up to 4000 A
up to 5000 A
up to 6300 A

A 0 5
A 0 5
A 0 5

x
x
x

x
x
x

Special packaging

Add. price

Special packaging for extended technical requirements


Cardboard packaging with wax coating (moisture protection),
internal bracing, tilt indicators

A 6 0

Rated current modules / Rating plugs

x
Add. price

Only one module is possible per For size I, II


circuit breaker (not in conjunction
with electronic trip unit ETU15B).
As standard the overcurrent
releases are equipped with a rated
current module which is equal to
the maximum rated current circuit
breaker (In max). The rated current
of the selected rated current
module must be smaller than
For size I, II, III
In max.
For size II, III

For size III

250

B 0 2

without

315

B 0 3

without

400

B 0 4

without

500

B 0 5

without

630

B 0 6

without

800

B 0 8

without

1000

B 1 0

without

1250

B 1 2

without

1600

B 1 6

without

2000

B 2 0

without

2500

B 2 5

without

3200

B 3 2

without

4000

B 4 0

without

5000

B 5 0

without

6300

B 6 3

without

15

Rated
current In
A

Indication/operator control elements, door sealing frames


5-digit mechanical
operating cycles counter1)

C 0 1

Button with sealing cap


Electrical ON button
in the operator panel2)
Key operation with lock CES
Possible only for circuit breakers
with closing solenoid

C 1 1

C 1 2

Storage status
signaling switches 2) (S21)

1 NO

C 2 0

Ready-to-close signaling
switch (S20)

1 NO

C 2 2

For the first auxiliary trip unit (S22)

C 2 6

For the second auxiliary trip unit (S23)

C 2 7

Motor shutdown switch


in the operator panel3)

S 2 5

EMERGENCY-STOP pushbuttons Mushroom pushbutton instead of


the mechanical OFF pushbutton

S 2 4

Door sealing frames

T 4 0

Signaling

switches2)

x = additional price

4)

If ordering withdrawable circuit breaker and guide frame separately,


specify order code "A05" for withdrawable circuit breaker and guide frame.

5)

Not possible with circuit breakers with very high switching capacity C.

1)

Only possible with motorized operating mechanism.


2) Not possible with communications interface option, order code
"F02" or "F12".
3)
Only for circuit breakers with motorized operating mechanism,
not possible with order codes "C11", "C12".

Siemens LV 1 2008

15/23

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1 2 3 4 5

6 7

Add. price

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
@@@+. . . + . . .
Code for
"Further versions"Z

Lockout devices and remote resets


Automatic reset
of the lockout device

K 0 1

K 0 7

K 1 0
K 1 2
K 1 3

x
x
x

M
M
M
M

1
3
5
6

x
x
x
x

24
30
48

M2 1
M2 2
M2 3

x
x
x

60
110
220

M2 4
M2 5
M2 6

x
x
x

M
M
M
M

3
3
3
3

1
3
5
6

x
x
x
x

M
M
M
M

4
4
4
4

1
3
5
6

x
x
x
x

Breaker status sensor (BSS)

F 0 1

PROFIBUS communications interfaces4)


including COM15 and breaker status sensor (BSS)

F 0 2

MODBUS communications interfaces4)


including COM16 and breaker status sensor (BSS)

F 1 2

F 0 5

Tripped signaling switches1)2)

1 CO contact

Remote reset solenoid for displays and reset buttons


including automatic reset of the lockout device
AC 50/60 Hz V

V DC

-120
220 ... 240

24
125
220 ... 250

Motorized operating mechanisms and closing/opening solenoids


Motorized operating mechanisms
Only possible if the 13th digit of the Order No. = "1"

15

Motor
AC 50/60 Hz V

V DC

--110 ... 127


208 ... 240

24 ... 30
48 ... 60
110 ... 125
220 ... 250

0
0
0
0

Closing solenoids suitable for continuous duty, 100 % ON period


Only possible if the 13th digit of the Order No. = "1"
Activation solenoids
AC 50/60 Hz V

V DC

----110
230

Closing solenoids3) unsuitable for continuous duty, 5 % ON period


Only possible if the 13th digit of the Order No. = "1"
Activation solenoids
AC 50/60 Hz V

V DC

--110 ... 127


208 ... 240

24
48
110 ... 125
220 ... 250

Opening solenoids (shunt trip unit)


unsuitable for continuous duty, 5 % ON period
Activation solenoids
AC 50/60 Hz V

V DC

--110 ... 127


208 ... 240

24
48
110 ... 125
220 ... 250

Communication and measurement functions

Measurement function Plus


(without PROFIBUS/MODBUS communications interface)5)
x = additional price
1)

Not possible with communications interface option,


order code "F02" or "F12".
Not available for non-automatic air circuit breakers.
3)
Overexcited, i.e. closing time 25 ms (standard 60 ms).
4) If ordering withdrawable circuit breaker and guide frame separately,
specify order code "F02" or "F12" for withdrawable circuit breaker only.
5)
Additional voltage transformers are required for connection of the
measurement function Plus, see page 15/40.
2)

15/24

Siemens LV 1 2008

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1234 5 6 7

Add. price

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@ + . . . + . . .

Interlocks, covers, position indicator switches


Mutual mechanical
interlockings
(interlocking module
with Bowden wire 2 m)

Arc chute covers


Not available for
- 1000 V version (order code "A05")
- DC version
- 4000 A size II

Shutters
2-part
lockable
with padlocks 1)

Position indicator switches


for guide frames

Fixed-mounted circuit breaker

-Z

Order code
for fixedmounted
version

Order code
for withdrawable
version

@@@

@@@

S 5 5

-- -- --

For withdrawable circuit breakers -with guide frame

R 5 5

For guide frames

--

R 5 6

For withdrawable circuit breakers --

R 5 7

3-pole
Size I
Size II
Size III

----

R 1 0
R 1 0
R 1 0

x
x
x

4-pole
Size I
Size II
Size III

----

R 1 0
R 1 0
R 1 0

x
x
x

3-pole
Size I
Size II
Size III

----

R 2 1
R 2 1
R 2 1

x
x
x

4-pole
Size I
Size II
Size III

----

R 2 1
R 2 1
R 2 1

x
x
x

Connected Test
position
position

Disconnected
position

1 CO

1 CO

1 CO

--

R 1 5

3 CO

2 CO

1 CO

--

R 1 6

Add "Z" to the complete Order No. and


indicate the appropriate order code(s).

Order No. with "Z"


1 2 3 4 5

6 7

15

Code for
"Further versions"

Add. price

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
@@@

+. . . + . . .
Code for
"Further versions" Z

Overload and short-circuit protection for neutral conductors


Internal transformers for N conductors Size I
Only possible with 4-pole circuit breakers Size II
with ETU27B to ETU76B
Size III
Protection of the N conductors only
under single-pole loads
IT network electronics including
transformers for neutral conductor
protection2)

F 2 3

F 2 3

F 2 3

Size I

F 3 0

Size II

F 3 0

Size III

F 3 0

Common-mode interference
suppressor filters (e.g. in
IT networks, caused by
frequency converters)

F 3 1

Only possible with 4-pole circuit breakers


with ETU55B. IT network electronics is
included as standard with all other ETUs.

EMC filters
EMC filters

Insertion loss (asymmetric)


in the range 40 kHz to
10 MHz >40 dB.
x = additional price
1)
2)

Padlocks not included in scope of supply.


The testing of transformers with the 3WL9 111-0AT31-0AA0 or
3WL9 111-0AT32-0AA0 manual tester is not possible.

Siemens LV 1 2008

15/25

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


8 9 10 11 12

1234 5 6 7

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@ + . . . + . . .

15

Code for
"Further versions"

-Z

Order code Add. price for


for fixedfixed-mounted
mounted
version
version

Order code Add. price


for withfor withdrawdrawable
able version
version

Locking devices

@@@

@@@

Locking devices against


unauthorized closing,
in the operator panels
Made by CES
The disconnector unit fulfills the
requirements for main circuit breakers Made by IKON
according to EN 60204 (VDE 0113)
Assembly kit FORTRESS or Castell1)

S 0 1

S 0 1

S 0 3

S 0 3

S 0 5

S 0 5

Assembly kit for padlocks2)

S 0 7

S 0 7

Made by Ronis

S 0 8

S 0 8

Made by Profalux

S 0 9

S 0 9

EMERGENCY-STOP pushbuttons Mushroom pushbutton instead of


the mechanical OFF pushbutton

S 2 4

S 2 4

Locking devices against


Made by CES
unauthorized closing,
Made by Ronis
for withdrawable circuit breakers
Made by Profalux
The disconnector unit fulfills the
requirements for main circuit
breakers according to EN 60204
(VDE 0113),
consisting of a lock in the cabinet
door, active in the connected position;
the function is retained when the
circuit breaker is replaced

--

R 6 1

--

R 6 8

--

R 6 0

Locking devices for operating


mechanism handles
with padlock2)

S 3 3

S 3 3

Locking devices to prevent


Made by CES
movement of the withdrawable cir- Made by Profalux
cuit breakers
Made by Ronis
Safety lock for mounting on
the circuit breaker

--

S 7 1

--

S 7 5

--

S 7 6

--

R 8 1

--

R 8 5

--

R 8 6

R 3 0

R 5 0

P 6 1

Locking mechanisms
Locking devices to prevent
Made by CES
movement of the withdrawable
Made by Profalux
circuit breakers in disconnected
Made by Ronis
positions,
consisting of Bowden wire and lock
in the cabinet door
Locking devices

To prevent opening of the cabinet door in: S 3 0


ON position (fixed-mounted version)/
in connected position (withdrawable version)
To prevent movement
with the cabinet door open

--

Connection methods for auxiliary conductors


Connections for screwless
terminals (tension spring)
x = additional price
1)
2)

Locks must be ordered from the manufacturer.


Padlock not included in the scope of supply.

15/26

Siemens LV 1 2008

N 6 1

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
+. . . + . . .
@@@
Code for
"Further versions"Z

For withdrawable circuit breakers with guide frames


or without guide frames

Add. price
3-pole

Add. price
4-pole

To select this connection method,


the 12th digit of the Order No. for the
circuit breaker must be a "6"
Connection methods for main circuit connections
Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

0
0
0
0
0

x
x
x
x
x

x
x
x
x
x

Top and bottom:


accessible from front,
double hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

1
1
1
1
1

x
x
x
x
x

x
x
x
x
x

Top:
horizontal,
double hole
Bottom:
accessible from front,
single hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

7
7
7
7
7

x
x
x
x
x

x
x
x
x
x

Top:
vertical
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

P
P
P
P
P
P

1
1
1
1
1
1

8
8
8
8
8
8

x
x
x
x
x
x

x
x
x
x
x
x

Top:
connecting flange
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

1
1
1
1
1

9
9
9
9
9

x
x
x
x
x

x
x
x
x
x

Top:
horizontal
Bottom:
vertical

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

P
P
P
P
P
P

2
2
2
2
2
2

3
3
3
3
3
3

x
x
x
x
x
x

x
x
x
x
x
x

Add. price
3-pole

Add. price
4-pole

For fixed-mounted circuit breakers

15

Top and bottom:


accessible from front,
single hole

To select this connection method,


the 12th digit of the Order No. for the
circuit breaker must be a "2"
Connection methods for main circuit connections
Top:
horizontal
Bottom:
accessible from front,
single hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

N
N
N
N
N

1
1
1
1
1

1
1
1
1
1

x
x
x
x
x

x
x
x
x
x

Top:
vertical
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

N
N
N
N
N
N

2
2
2
2
2
2

0
0
0
0
0
0

x
x
x
x
x
x

x
x
x
x
x
x

Top:
horizontal
Bottom:
vertical

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

N
N
N
N
N
N

2
2
2
2
2
2

4
4
4
4
4
4

x
x
x
x
x
x

x
x
x
x
x
x

x = additional price

Siemens LV 1 2008

15/27

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts

Overview
Determination of the number of auxiliary supply connectors required

NSE0_01104

This selection is only required if the guide frame is ordered under a


separate Order No.
X7

X6

The required number of auxiliary supply connectors


depends on:
Operating mechanism type
Electronic trip unit with/without current transformer
Type and number of auxiliary trip units
Number of auxiliary switches
COM15/COM16 communication interface

X5

X8

15

Number of auxiliary
supply connectors

Terminal

First auxiliary supply connector X6 always required.

X6

b
b1
b2
b3

Operating mechanisms
Manual operating mechanism with stored-energy feature with mechanical closing
Manual operating mechanism with stored-energy feature with mechanical and electrical closing
Manual/motorized operating mechanism with stored-energy feature with mechanical and electrical closing

0
0
+1

X6
X5

c
c1
c2

Electronic trip units


Electronic trip units ETU15B, ETU25B, ETU27B
Electronic trip units ETU45B, ETU55B, ETU76B (internal CubicleBUS)

0
+1

X8

c3
c4

Connections for external current transformers for overload protection in the N conductor and ground-fault protection
Current transformer installed in the N conductor (required with 3-pole circuit breakers if c2 is not selected)
Current transformer in the neutral point of the transformer (required if c2 or c3 is not selected)

+1
+1

X8
X8

d
d1
d2

Auxiliary trip units


With/without 1st auxiliary trip unit (shunt trip unit F1)
2nd auxiliary trip unit (shunt trip unit F2, undervoltage trip unit F3, delayable undervoltage trip unit F4)

0
+1

X6
X5

e
e1
e2

Auxiliary switch blocks


1st auxiliary switch block 2 NO + 2 NC
1st and 2nd auxiliary switch block 4 NO + 4 NC or 6 NO + 2 NC or 5 NO + 3 NC (required if b3 or d2 is not selected)

0
+1

X6
X5

f
f1
f2

Communications modules
Without communications module COM15/COM16
With communications module COM15/COM16
occupies the entire terminal strip X7, making the following options no longer possible:
Tripped signal switch S24
Stored-energy status indication S21
Electrical ON button S10
Signaling switch on first and second auxiliary trip unit S22 + S23

0
+1

X7

g
g1
g2
g3
g4
g5

+1
+1
+1
+1
+1

X7
X7
X7
X7
X7

g6
g7
g8

Optional signals/accessories
Tripped signal switch S24 (only possible if f2 is not selected)
Stored-energy status indication S21 (only possible if f2 is not selected, required if g1 is not selected)
Electrical ON button S10 (only possible if f2 is not selected, required if g1 or g2 is not selected)
Signaling switch on first auxiliary trip unit S22 (only possible if f2 is not selected, required if g1, g2 or g3 is not selected)
Signaling switch on second auxiliary trip unit S23 (only possible if f2 is not selected, required if g1, g2, g3 or g4 is not
selected)
Ready-to-close signaling switch S20
Motor shutdown switch S12 (only possible if motorized operating mechanism is selected)
Remote reset magnet F7 (required if c2 is not selected)

0
0
+1

X6
X5
X8

Total number of auxiliary supply connectors

(max. 4)

Selection and ordering data


Guide frames for AC circuit breakers/non-automatic air circuit breakers, 3 and 4-pole, for 1000 V AC
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

Order No. with "Z"


and additional order code
1234 5 6 7

8 9 10 11 12

Add. price
13 14 15 16

3WL9 2 1 . - . . . . . - . . . . -Z
@@@

Code for
"Further versions"-Z
Rated voltage 1000 V AC
Size II, except 4000 A (switching capacity H)

A 0 5

Size III, not necessary with circuit breakers with


very high switching capacity C

A 0 5

For ordering guide frames see pages 15/29 and 15/30.


x = additional price

15/28

Siemens LV 1 2008

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Guide frames for AC circuit breakers/non-automatic air circuit breakers
Size

Max. rated circuit breaker


current
In max.

Switching
capacity
Icu

kA

DT

Guide frames for 3-pole circuit breakers/ PU


PS*
non-automatic air circuit breakers
(UNIT,
Order No.
Basic price SET, M)

PG

(Order No. supplements required per PU


according to table below)

Weight
per PU
approx.
kg

Front main circuit connection, single hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AA@@-@@A1
3WL9 211-2AA@@-@@A1
3WL9 212-3AA@@-@@A1
3WL9 212-4AA@@-@@A1
3WL9 212-5AA@@-@@A1
3WL9 213-6AA@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AB@@-@@A1
3WL9 211-2AB@@-@@A1
3WL9 212-3AB@@-@@A1
3WL9 212-4AB@@-@@A1
3WL9 212-5AB@@-@@A1
3WL9 213-6AB@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 150
... 150

B
B
B
B
B
B
B
B
B

3WL9 211-1AC@@-@@A1
3WL9 211-2AC@@-@@A1
3WL9 212-3AC@@-@@A1
3WL9 212-4AC@@-@@A1
3WL9 212-5AC@@-@@A1
3WL9 213-6AC@@-@@A1
3WL9 213-7AC@@-@@A1
3WL9 213-6AC@@-@@C1
3WL9 213-7AC@@-@@C1

1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000
60.000
63.000
63.000

... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 150
... 150
... 150

B
B
B
B
B
B
B
B
B
B
B
B

3WL9 211-1AD@@-@@A1
3WL9 211-2AD@@-@@A1
3WL9 212-3AD@@-@@A1
3WL9 212-4AD@@-@@A1
3WL9 212-5AD@@-@@A1
3WL9 212-6AD@@-@@A1
3WL9 213-6AD@@-@@A1
3WL9 213-7AD@@-@@A1
3WL9 213-8AD@@-@@A1
3WL9 213-6AD@@-@@C1
3WL9 213-7AD@@-@@C1
3WL9 213-8AD@@-@@C1

1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
52.000
60.000
60.000
70.000
63.000
63.000
74.000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AE@@-@@A1
3WL9 211-2AE@@-@@A1
3WL9 212-3AE@@-@@A1
3WL9 212-4AE@@-@@A1
3WL9 212-5AE@@-@@A1
3WL9 213-6AE@@-@@A1
Order No. supplements
0
1
2
3
4

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

Front main circuit connection, double hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Horizontal main circuit connection


I
I
II
II
II
III
III
III
III

1000
1600
2000
2500
3200
4000
5000
4000
5000
1000
1600
2000
2500
3200
4000
4000
5000
6300
4000
5000
6300

Main circuit connection connecting flanges


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Number of auxiliary supply connectors


None
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 15/28

Add. price
without
x
x
x
x

Type of auxiliary circuit connections


None
With screw connections (SIGUT)
With screwless connection method (tension spring)

without
x
x

0
1
2

Position indicator switches


None
Option 1
Option 2

Connected position 1 CO contacts,


test position 1 CO contacts,
disconnected position 1 CO contact
Connected position 3 CO contacts,
test position 2 CO contacts,
disconnected position 1 CO contact

0
1

without
x

Shutters
None
With shutter,
2-part,
lockable

Size I
Size II
Size III

A
B

without
x
x
x

x = additional price

For rated voltage 1000 V AC see page 15/28.


All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see pages 15/23 to 15/27.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/29

15

Vertical main circuit connection


I
I
II
II
II
II
III
III
III
III
III
III

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Size

Max. rated circuit breaker


current
In max.

Switching
capacity Icu

kA

DT

Guide frames for 4-pole circuit breakers/ PU


PS*
non-automatic air circuit breakers
(UNIT,
Order No.
Basic price SET, M)

PG

(Order No. supplements required per PU


according to table below)

Weight
per PU
approx.
kg

Front main circuit connection, single hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BA@@-@@A1
3WL9 211-2BA@@-@@A1
3WL9 212-3BA@@-@@A1
3WL9 212-4BA@@-@@A1
3WL9 212-5BA@@-@@A1
3WL9 213-6BA@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BB@@-@@A1
3WL9 211-2BB@@-@@A1
3WL9 212-3BB@@-@@A1
3WL9 212-4BB@@-@@A1
3WL9 212-5BB@@-@@A1
3WL9 213-6BB@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000

... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 130
... 130

B
B
B
B
B
B
B
B
B

3WL9 211-1BC@@-@@A1
3WL9 211-2BC@@-@@A1
3WL9 212-3BC@@-@@A1
3WL9 212-4BC@@-@@A1
3WL9 212-5BC@@-@@A1
3WL9 213-6BC@@-@@A1
3WL9 213-7BC@@-@@A1
3WL9 213-6BC@@-@@C1
3WL9 213-7BC@@-@@C1

1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000
84.000
87.000
87.000

... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 130
... 130
... 130

B
B
B
B
B
B
B
B
B
B
B
B

3WL9 211-1BD@@-@@A1
3WL9 211-2BD@@-@@A1
3WL9 212-3BD@@-@@A1
3WL9 212-4BD@@-@@A1
3WL9 212-5BD@@-@@A1
3WL9 212-6BD@@-@@A1
3WL9 213-6BD@@-@@A1
3WL9 213-7BD@@-@@A1
3WL9 213-8BD@@-@@A1
3WL9 213-6BD@@-@@C1
3WL9 213-7BD@@-@@C1
3WL9 213-8BD@@-@@C1

1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103 30.000
103 30.000
103 37.000
103 47.000
103 54.000
103 62.000
103 84.000
103 84.000
103 119.000
103 88.000
103 88.000
103 124.000

... 100
... 100
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BE@@-@@A1
3WL9 211-2BE@@-@@A1
3WL9 212-3BE@@-@@A1
3WL9 212-4BE@@-@@A1
3WL9 212-5BE@@-@@A1
3WL9 213-6BE@@-@@A1
Order No. supplements
0
1
2
3
4

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

Front main circuit connection, double hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Horizontal main circuit connection


I
I
II
II
II
III
III
III
III

1000
1600
2000
2500
3200
4000
5000
4000
5000

15

Vertical main circuit connection


I
I
II
II
II
II
III
III
III
III
III
III

1000
1600
2000
2500
3200
4000
4000
5000
6300
4000
5000
6300

Main circuit connection connecting flanges


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Number of auxiliary supply connectors


None
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 15/28

30.000
30.000
37.000
47.000
54.000
84.000

Add. price
without
x
x
x
x

Type of auxiliary circuit connections


None
With screw connections (SIGUT)
With screwless connection method (tension spring)

without
x
x

0
1
2

Position indicator switches


None
Option 1

Connected position 1 CO contacts,


test position 1 CO contacts,
disconnected position 1 CO contact
Connected position 3 CO contacts,
test position 2 CO contacts,
disconnected position 1 CO contact

Option 2

0
1

without
x

Shutters
None
With shutter,
2-part,
lockable

Size I
Size II
Size III

A
B

without
x
x
x

x = additional price

For rated voltage 1000 V AC see page 15/28.


All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see pages 15/23 to 15/27.

15/30

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

NSE0_01610b

Protective devices with device holder and optional measurement function1)


Type

With protection
function

Measurement
function

ETU15B

LI

without

3WL9 311-5AA00-0AA2

1 1 unit

103 on req.

ETU25B

LSI

without

3WL9 312-5AA00-0AA2

1 1 unit

103 on req.

ETU27B

LSING

without

3WL9 312-7AA00-0AA2

1 1 unit

103 on req.

ETU45B
LSIN(G)
(without display)

without
with measurement
function Plus

C
B

3WL9 314-5AA00-0AA2
3WL9 314-5AA20-0AA2

1 1 unit
1 1 unit

103 on req.
103 on req.

ETU55B

LSIN(G)

without
with measurement
function Plus

C
B

3WL9 315-5AA00-0AA1
3WL9 315-5AA20-0AA1

1 1 unit
1 1 unit

103
103

ETU76B

LSIN(G)

without
with measurement
function Plus

C
B

3WL9 317-6AA00-0AA2
3WL9 317-6AA20-0AA2

1 1 unit
1 1 unit

103 on req.
103 on req.

250
315
400
500

B
B
B
B

3WL9 111-0AA51-0AA0
3WL9 111-0AA52-0AA0
3WL9 111-0AA53-0AA0
3WL9 111-0AA54-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.010
0.010
0.010
0.010

630
800
1000

B
B
B

3WL9 111-0AA55-0AA0
3WL9 111-0AA56-0AA0
3WL9 111-0AA57-0AA0

1 1 unit
1 1 unit
1 1 unit

103
103
103

0.010
0.010
0.010

I, II, III

1250
1600

B
B

3WL9 111-0AA58-0AA0
3WL9 111-0AA61-0AA0

1 1 unit
1 1 unit

103
103

0.010
0.010

II, III

2000
2500
3200
4000

B
B
B
B

3WL9 111-0AA62-0AA0
3WL9 111-0AA63-0AA0
3WL9 111-0AA64-0AA0
3WL9 111-0AA65-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.010
0.010
0.010
0.010

III

5000
6300

B
B

3WL9 111-0AA66-0AA0
3WL9 111-0AA67-0AA0

1 1 unit
1 1 unit

103
103

0.010
0.010

3WL9 31.-.AA.0-0AA1

0.720
0.720

Rated current modules / Rating plugs2)


I, II

N S E 0 _ 0 0 9 9 2 b

3WL9 111-0AA64-0AA0

Rated current In (A)

Ground-fault modules3)
GFM AT 45B (only for ETU45B) alarm and tripping

3WL9 111-0AT53-0AA0

1 1 unit

103

0.030

GFM AT 55B76B (only for ETU55B, ETU76B) alarm and


tripping

3WL9 111-0AT56-0AA0

1 1 unit

103

0.030

4-line displays for ETU45B

3WL9 111-0AT81-0AA0

1 1 unit

103

0.060

Size I
Size II
Size III

B
B
B

3WL9 111-0AA11-0AA0
3WL9 111-0AA12-0AA0
3WL9 111-0AA13-0AA0

1 1 unit
1 1 unit
1 1 unit

103
103
103

0.200
0.280
0.500

External transformers for


Size I
N conductors
Size II
(T5, see Technical Information LV 1 T, Size III
3WL9 111-0AA2.-0AA0
"Functions", "Measurement Method")

B
B
B

3WL9 111-0AA21-0AA0
3WL9 111-0AA22-0AA0
3WL9 111-0AA23-0AA0

1 1 unit
1 1 unit
1 1 unit

103
103
103

0.300
0.380
0.680

Size I
External transformers for
N conductors
Size II
With copper connection pieces
Size III
(T5, see Technical Information LV 1 T,
"Functions", "Measurement Method")

B
B
B

3WL9 111-0AA31-0AA0
3WL9 111-0AA32-0AA0
3WL9 111-0AA33-0AA0

1 1 unit
1 1 unit
1 1 unit

103
103
103

1.600
4.260
8.500

Size I
Size II
Size III

B
B
B

3WL9 111-0AA14-0AA0
3WL9 111-0AA15-0AA0
3WL9 111-0AA16-0AA0

1 1 unit
1 1 unit
1 1 unit

103
103
103

0.200
0.280
0.500

3WL9 111-0AK32-0AA0

1 1 unit

103 on req.

3WL9 111-0AK34-0AA0

1 1 unit

103

G F M

A T 4 5 B

5 1
g T R IP

A L A R M

A L A R M

T R IP
C
D

O F F

J g (s )
.5

1 2 Jg
.1

.4

.2

.3

.3

.2

.4

.1

.5

N S E 0 _ 0 1 0 2 7 a

3WL9 111-0AT53-0AA0

Displays

N S E 0 _ 0 1 6 0 9

3WL9 111-0AT81-0AA0

Transformers for neutral conductor protection


Internal transformers for
N conductors
(nicht fr ETU Release 2)
Including wiring kit
N S E 0 _ 0 0 9 9 0 a

N S E 0 _ 0 0 9 9 1 a

3WL9 111-0AA3.-0AA0

Internal transformers for


N conductors
fr ETU Release 2
Including wiring kit

EMC filters
not for ETU Release 2
EMC filters
Common-mode interference sup- not for ETU Release 2
pressor filters (e.g. in IT networks,
caused by frequency converters)
Insertion loss (asymmetric) in the
range 40 kHz to 10 MHz >40 dB
1)
2)

For replacement in existing circuit breakers please specify the circuit breaker ID No.
when ordering.
With the rated current module selected, the maximum rated current In max of the circuit
breaker must not be exceeded. The following applies In In max.

* You can order this quantity or a multiple thereof.

3)

0.280

For direct measurement of the ground-fault current, e.g. in the neutral point of the
transformer, a 1200 A/1 A current transformer, class 1, is required. The internal load of
the SENTRON 3WL is 0.11 m. If the ground-fault current is to be determined using the
vectorial sum of the phases, a transformer must be installed in the neutral conductor.

Siemens LV 1 2008

15/31

15

For size
n = 3 2 0 0 A

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET,
M)

PG

Weight
per PU
approx.
kg

Locking devices, operator control elements


NSE0_00983b

Sealable covers

ETU25B

N S E 0 _ 0 0 9 9 9 a

3WL9 111-0AK0.-0AA0

3WL9 111-0AT45-0AA0

1 1 unit

For ETU76

103

0.050
0.050

3WL9 111-0AT46-0AA0

1 1 unit

103

Automatic reset of the lockout devices


B
Spare part for option K01, see "-Z" + order code, page 15/24.

3WL9 111-0AK21-0AA0

1 1 unit

103 on req.

Remote reset solenoids1)


For mechanical tripped indicator

24 V DC

3WL9 111-0AK03-0AA0

1 1 unit

103

0.200

48 V DC

3WL9 111-0AK04-0AA0

1 1 unit

103

0.200

Spare part for option K10 to K13,


see "-Z" + order code, page 15/24.

120 V AC/
125 V DC

3WL9 111-0AK05-0AA0

1 1 unit

103

0.200

220-240 V AC/
220-250 V DC

3WL9 111-0AK06-0AA0

1 1 unit

103

0.200

Retrofittable internal CubicleBUS wiring For ETU45B to


for connection to terminal X8
ETU76B
(without male connector2))

3WL9 111-0AK30-0AA0

1 1 unit

103

0.150

Retrofittable internal wiring for connection of


the external N- and G-transformers to terminal X8
(without male connector, not for ETU release 2)

3WL9 111-0AK31-0AA0

1 1 unit

103

0.020

Retrofittable internal wiring for connection of


the external N- and G-transformers to terminal X8
for ETU release 2 (without male connector)

3WL9 111-0AK33-0AA0

1 1 unit

103

0.020

Without safety lock B


Made by CES
Made by IKON
B
B

3WL9 111-0BA21-0AA0

1 unit

103

0.100

3WL9 111-0BA22-0AA0
3WL9 111-0BA24-0AA0

1
1

1 unit
1 unit

103
103

0.300
0.300

Assembly kit
FORTRESS or
CASTELL3)
Made by Ronis
Made by KIRK-Key
Made by Profalux

3WL9 111-0BA31-0AA0

1 unit

103

0.200

B
B
B

3WL9 111-0BA33-0AA0
3WL9 111-0BA34-0AA0
3WL9 111-0BA35-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.400
0.270
0.250

Made by CES
Made by IKON
Assembly kit for
padlocks4)

B
B

3WL9 111-0BA36-0AA0
3WL9 111-0BA38-0AA0

1
1

1 unit
1 unit

103
103

0.200
0.200

3WL9 111-0BA41-0AA0

1 unit

103

0.360

Made by CES
Made by IKON
Made by KIRK-Key
Made by Ronis
Made by Profalux

B
B
B
B
B

3WL9 111-0BA51-0AA0
3WL9 111-0BA53-0AA0
3WL9 111-0BA57-0AA0
3WL9 111-0BA58-0AA0
3WL9 111-0BA50-0AA0

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

0.300
0.300
0.300
0.300
on req.

3WL9 111-0BA71-0AA0

1 unit

103

0.080

B
B
B
B
B

3WL9 111-0BA73-0AA0
3WL9 111-0BA75-0AA0
3WL9 111-0BA76-0AA0
3WL9 111-0BA77-0AA0
3WL9 111-0BA80-0AA0

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

0.300
0.200
0.300
0.300
0.400

3WL9 111-0BA43-0AA0

1 unit

103

0.360

3WL9 111-0AT45-0AA0
F 7

For ETU15B to
ETU55B

Locking devices

NSE00980

15

Protective covers for


mechanical ON/OFF
Consisting of 2 transparent covers
each for sealing or for attaching
padlocks4), cover with 6.35 mm hole
(for tool actuation), lock mount for
safety lock for key operation

Locking devices against


3WL9 111-0BA22-0AA0 unauthorized closing,
in the operator panel
The disconnector unit
fulfills the requirements for
main circuit breakers
according to
EN 60204 (VDE 0113)
NSE00981

Spare part for option S01 to S09,


see "-Z" + order code, page 15/26.

3WL9 111-0BA31-0AA0 Locking devices against


unauthorized closing,
for withdrawable circuit breakers
The disconnector unit fulfills the
requirements for main circuit breakers
according to EN 60204 (VDE 0113)
consisting of lock in the cabinet door, active
NSE00982
in connected position; function is retained
3WL9 111-0BA53-0AA0 when circuit breaker is replaced
Spare part for option R60, R61, R68,
see "-Z" + order code, page 15/26.
Locking devices for operating
mechanism handle with padlock4)
Spare part for option S33, see
"-Z" + order code, page 15/26.
Locking devices against movement
of the withdrawable circuit breakers
Safety lock for mounting
on the circuit breaker.

NSE00984

Spare part for option S71, S75, S76,


3WL9 111-0BA71-0AA0 see "-Z" + order code, page 15/26.

NSE00986

3WL9 111-0BA76-0AA0

Made by CES
Made by IKON
Made by Profalux
Made by Ronis
Made by KIRK-Key

Interlocking systems
Made by CES
2 of the same keys for 3 switches,
Locking device OFF position,
Key-operated switch on operator panel.
A maximum of 2 switches can be
switched on.

1)

Can only be used in conjunction with "automatic reset of lockout device",


e.g. "Z" + "K01", 3WL9 111-0AK21-0AA0
2) Required if communication is retrofitted.

15/32

Siemens LV 1 2008

3)
4)

Locks must be ordered from the manufacturer.


Padlock not included in the scope of supply.
Start of delivery on request.

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Locking mechanisms
To prevent movement of the
withdrawable circuit breakers
in disconnected positions,
consisting of Bowden wire and
lock in the cabinet door

NSE00987

Made by CES
Made by IKON
Made by Profalux
Made by Ronis

B
B
B
B

3WL9 111-0BA81-0AA0
3WL9 111-0BA83-0AA0
3WL9 111-0BA85-0AA0
3WL9 111-0BA86-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.800
0.800
0.800
0.800

Fixed mounting

3WL9 111-0BB12-0AA0

1 unit

103

on req.

Guide frames

3WL9 111-0BB13-0AA0

1 unit

103

0.150

Guide frames

3WL9 111-0BB15-0AA0

1 unit

103

on req.

Fixed-mounted circuit
breaker

3WL9 111-0BB21-0AA0

1 unit

103

2.700

Module for withdrawable B


circuit breaker with frame

3WL9 111-0BB24-0AA0

1 unit

103

1.130

3WL9 111-0BB22-0AA0

1 unit

103

1.100

Module for withdrawable B


circuit breaker

3WL9 111-0BB23-0AA0

1 unit

103

0.150

3WL9 111-0BB30-0AA0

1 unit

103

on req.

3WL9 112-8AH47-0AA0

1 unit

103

0.160

B
B
B

3WL9 111-0BB45-0AA0
3WL9 111-0BB46-0AA0
3WL9 111-0BB47-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.150
0.220
0.360

3WL9 111-0BA83-0AA0 Spare part for option R81, R85, R86,


see "-Z" + order code, page 15/26.
To prevent opening of the
cabinet door in ON position
(can be defeated)
Spare part for option S30,
see "-Z" + order code, page 15/26.
3WL9 111-0BB12-0AA0 To prevent opening of the
cabinet door (can be defeated)
Interlocking
Spare part for option R30,
see "-Z" + order code, page 15/26.
To prevent movement with the
cabinet door open
Spare part for option R50,
see "-Z" + order code, page 15/26.

Interlocks

NSE00989

3WL9 111-0BB21-0AA0

Spare part for option S55,


see "-Z" + order code,
page 15/25.

15

Mutual mechanical interlocking,


with 2000 mm Bowden wire
(one required for each circuit
breaker)

Spare part for option R55,


see "-Z" + order code,
page 15/25.
When ordered separately
Module for guide frame
Spare part for option R56,
see "-Z" + order code,
page 15/25.

Spare part for option R57,


see "-Z" + order code,
page 15/25.
Adapter for size III
Withdrawable circuit
breaker
Couplings on the circuit
breaker (with ring) for
mutual interlocking
Can be used in all circuit breakers
Bowden wires
NSE0_01886

3WL9 112-8HA47-0AA0

* You can order this quantity or a multiple thereof.

2000 mm
3000 mm
4500 mm

Siemens LV 1 2008

15/33

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Test devices
Manual testers release 2 for electronic trip units
ETU15B to ETU76B1)

3WL9 111-0AT32-0AA0

1 unit

103

1.100

3WL9 111-0AT44-0AA0

1 unit

103

8.210

For testing the electronic trip unit functions


Function testers
For testing the tripping characteristics for
electronic trip unit ETU15B to ETU76B

Capacitor storage devices


Capacitor storage devices
For shunt trip unit

Rated control supply voltage/


rated operational voltage

Storage time 5 min

AC 50/60 Hz V
Rated control supply voltage must 110 ... 127
match the rated control supply
voltage of the shunt trip unit
220 ... 240

V DC
110 ...
115

3WL9 111-0BA13-0AA0

1 unit

103

0.380

220 ...
250

3WL9 111-0BA14-0AA0

1 unit

103

0.520

Suitable also for 3VL and 3WN circuit breakers


The testing of converters is not possible for use of the ETU55B and the
options "F30", "Protection of the N conductor under single-pole load",
"F31" and 3WL9 111-0AK32 "EMC filter".

15

1)

15/34

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Indicators, control elements


Ready-to-close indicator switches
1 NO contact

3WL9 111-0AH01-0AA0

1 unit

103

0.020

3WL9 111-0AH02-0AA0

1 unit

103

0.020

3WL9 111-0AH14-0AA0

1 unit

103

0.080

3WL9 111-0AH07-0AA0

1 unit

103

0.100

3WL9 111-0AH08-0AA0

1 unit

103

0.030

3WL9 111-0AH11-0AA0

1 unit

103

0.200

3WL9 111-0AH12-0AA0

1 unit

103

0.400

Spare part for option C22,


see "-Z" + order code,
page 15/23.
Signaling switches1)2)

N S E 0 _ 0 0 9 9 3 a

Spare part for option C26


and C27, see "-Z" + order
code, page 15/23.

1st or 2nd auxiliary trip


units

Tripped signaling switches1)2)

3WL9 111-0AH01-0AA0 1 CO
Spare part for option K07,
see "-Z" + order code,
page 15/24.
N S E 0 _ 0 0 9 9 4 b

Operating cycles counters,


mechanical3)
Spare part for option C01,
see "-Z" + order code,
page 15/23.
Stored energy status signaling

3WL9 111-0AH02-0AA0 switches1)2)

Spare part for option C20,


see "-Z" + order code,
page 15/23.
Position indicator switches 1st block
(3 CO contacts)
for guide frames
Spare part for option
R15 and R16,
3WL9 111-0AH07-0AA0 see "-Z" + order code,
page 15/25.

2nd block
(6 CO contacts)

Electrical ON buttons1)4)
(button+wiring)2),
for operator panel.
N S E 0 _ 0 0 9 9 6 a
Possible only for circuit
3WL9 111-0AH12-0AA0 breakers with closing
solenoid.

With sealing cap

3WL9 111-0AJ02-0AA0

1 unit

103

0.150

With CES assembly kit

3WL9 111-0AJ03-0AA0

1 unit

103

0.140

With BKS assembly kit

3WL9 111-0AJ04-0AA0

1 unit

103

0.140

With IKON assembly kit

3WL9 111-0AJ05-0AA0

1 unit

103

0.140

3WL9 111-0AJ06-0AA0

1 unit

103

0.100

3WL9 111-0BA72-0AA0

1 unit

103

0.080

N S E 0 _ 0 0 9 9 5 a

Spare part for option C11


and C12, see "-Z" + order
code, page 15/23.
N S E 0

0 0 9 9 7 a

3WL9 111-0AJ0.-0AA0

Motor shutdown switches 5)


(mounting on operator panel)
Spare part for option S25,
see "-Z" + order code,
page 15/23.
EMERGENCY-STOP pushbuttons
Mushroom pushbutton instead of
the mechanical OFF pushbutton

NSE00985

Spare part for option S24,

3WL9 111-0BA72-0AA0 see "-Z" + order code,


page 15/23.
1)
2)

Not possible with communications interface option, order code "F02" or "F12".

3)

Only in conjunction with motorized operating mechanism.

X7 manual connector required for circuit breakers or guide frames. If this is


not already available, please order additionally
(see pages 15/28 and 15/36).

4)

Not possible with motor shutdown switch.

5)

Not possible with electrical ON button.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/35

15

1 NO contact

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Auxiliary conductor connections


B

3WL9 111-0AB01-0AA0

1 unit

103

0.100

Extension for the 1000 V male connector versions B


(male connector must be ordered separately)

3WL9 111-0AB02-0AA0

1 unit

103

on req.

3WL9 111-0AB10-0AA0

1 unit

103

1.000

Screw connection
B
(SIGUT)
Screwless connection B
method
(tension spring)

3WL9 111-0AB03-0AA0

1 unit

103

0.070

3WL9 111-0AB04-0AA0

1 unit

103

0.070

3WL9 111-0AB07-0AA0

1 unit

103

0.020

Sliding contact modules for guide frames

3WL9 111-0AB08-0AA0

1 unit

103

0.100

One-part sliding contact modules for guide


frames Screw connection (SIGUT)

3WL9 111-0AB18-0AA0

1 unit

103

0.120

Blanking blocks for circuit breakers

3WL9 111-0AB12-0AA0

1 unit

103

0.030

NSE00978

Male connectors for circuit breakers

3WL9 111-0AB01-0AA0

Male connectors for extension for 1000 V

N S E 0 _ 0 1 2 6 8

Auxiliary supply
connectors for circuit
breakers or guide
frames

N S E 0 _ 0 1 2 6 9

3WL9 111-0AB03-0AA0

3WL9 111-0AB04-0AA0 Coding kits

NSE00974

15

For fixed-mounted version (X5 to X8)

3WL9 111-0AB07-0AA0

a
7 7
0 9
_ 0
E 0
S
N

NSE0_01586

3WL9 111-0AB08-0AA0

3WL9 111-0AB18-0AA0

15/36

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Auxiliary trip units


Closing solenoids/shunt trip units
24 V DC

3WL9 111-0AD06-0AA0

3WL9 111-0AD01-0AA0

1 unit

103

0.700

30 V DC

3WL9 111-0AD02-0AA0

1 unit

103

0.700

48 V DC

3WL9 111-0AD03-0AA0

1 unit

103

0.700

60 V DC

3WL9 111-0AD04-0AA0

1 unit

103

0.700

110 ... 125 V DC/110 V AC

3WL9 111-0AD05-0AA0

1 unit

103

0.700

220 V DC/230 V AC

3WL9 111-0AD06-0AA0

1 unit

103

0.700

24 V DC

100 % ON period

5 % ON period

3WL9 111-0AD11-0AA0

1 unit

103

0.700

3WL9 111-0AD12-0AA0

1 unit

103

0.700

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AD13-0AA0

1 unit

103

0.700

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AD14-0AA0

1 unit

103

1.800

24 V DC

3WL9 111-0AE01-0AA0

1 unit

103

0.730

30 V DC

3WL9 111-0AE02-0AA0

1 unit

103

0.730

48 V DC

3WL9 111-0AE03-0AA0

1 unit

103

0.730

60 V DC

3WL9 111-0AE07-0AA0

1 unit

103

0.730

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AE04-0AA0

1 unit

103

0.730

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AE05-0AA0

1 unit

103

0.730

380 ... 415 V AC

3WL9 111-0AE06-0AA0

1 unit

103

0.730

48 V DC

NSE01001

Undervoltage trip units

NSE01002

Instantaneous

3WL9 111-0AE1.-0AA0
Delayed
B

3WL9 111-0AE11-0AA0

1 unit

103

0.740

110 ... 125 V DC/110 ... 127 V AC

48 V DC

3WL9 111-0AE12-0AA0

1 unit

103

0.740

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AE13-0AA0

1 unit

103

0.740

380 ... 415 V AC

3WL9 111-0AE14-0AA0

1 unit

103

0.740

Operating mechanisms
Motorized operating mechanisms1)

24 ... 30 V DC

3WL9 111-0AF01-0AA0

1 unit

103

1.510

48 ... 60 V DC

3WL9 111-0AF02-0AA0

1 unit

103

1.510

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AF03-0AA0

1 unit

103

1.510

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AF04-0AA0

1 unit

103

1.510

N S E 0 _ 0 1 0 0 3 a

3WL9 111-0AF0.-0AA0

Auxiliary contacts
Auxiliary switch blocks

2 NO + 2 NC

3WL9 111-0AG01-0AA0

1 unit

103

0.180

2 NO

3WL9 111-0AG02-0AA0

1 unit

103

0.080

1 NO + 1 NC

3WL9 111-0AG03-0AA0

1 unit

103

0.070

3WL9 111-0AG03-0AA0

1)

X7 manual connector required for circuit breakers or guide frames.


If this is not already available, please order additionally
(see pages 15/28 and 15/36).

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/37

15

3WL9 111-0AE0.-0AA0

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Door sealing frames, covers, shutters


B

3WL9 111-0AP01-0AA0

1 unit

103

0.360

3WL9 111-0AP02-0AA0

1 unit

103

1.600

Size I

3WL9 111-0AP04-0AA0

1 unit

103

0.500

Size II

3WL9 111-0AP06-0AA0

1 unit

103

0.630

Size III

3WL9 111-0AP07-0AA0

1 unit

103

0.860

Size I

3WL9 111-0AP08-0AA0

1 unit

103

0.600

Size II

3WL9 111-0AP11-0AA0

1 unit

103

0.770

Size III

3WL9 111-0AP12-0AA0

1 unit

103

1.070

Size I

3WL9 111-0AS01-0AA0

1 unit

103

1.110

Size II

3WL9 111-0AS02-0AA0

1 unit

103

1.680

Size III

3WL9 111-0AS03-0AA0

1 unit

103

2.980

Size II

3WL9 111-0AS05-0AA0

1 unit

103

3.140

Size III

3WL9 111-0AS06-0AA0

1 unit

103

5.620

Size I

3WL9 111-0AS32-0AA0

1 unit

103

1.850

Size II

3WL9 111-0AS36-0AA0

1 unit

103

2.600

Size III

3WL9 111-0AS38-0AA0

1 unit

103

4.050

Size I

3WL9 111-0AS42-0AA0

1 unit

103

2.340

Size II

3WL9 111-0AS44-0AA0

1 unit

103

3.300

Size III

3WL9 111-0AS46-0AA0

1 unit

103

5.210

3WL9 111-0AR12-0AA0

1 unit

103

0.400

Door sealing frames


Spare part for option T40,
see "-Z" + order code, page 15/23.
Protective covers, IP55
Cannot be used in conjunction with
door sealing frames, cover removable
and can be opened on both sides
Shutters

NSE0_01028a

3WL9 111-0AP02-0AA0

Spare part for option R21,


see "-Z" + order code, page 15/25.
3-pole

4-pole

3WL9 111-0AP0.-0AA0

Arc chutes

15

Arc chutes

NSE01007

690 V

3WL9 111-0AS0.-0AA0

1000 V
Arc chute covers1)
Parts kit for guide frame
Spare part for option R10,
see "-Z" + order code, page 15/25.
3-pole

NSE01008

3WL9 111-0AS3.-0AA0
4-pole

Withdrawable part coding


Withdrawable part coding
By customer, for 36 coding variants

NSE01009

3WL9 111-0AR12-0AA0
1)

Not available for 1000 V version, DC version and size II with rated circuit
breaker current of 4000 A.

15/38

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Ground-fault protection
Ground-fault protection between the guide frame
and the withdrawable circuit breakers
For 30 kA ground short-circuit current1)
Contact module for guide frame
NSE0 01018a

Size I, II

3WL9 111-0BA01-0AA0

1 1 unit

103

0.330

Size III

3WL9 111-0BA02-0AA0

1 1 unit

103

0.350

Size I

3WL9 111-0BA05-0AA0

1 1 unit

103

1.250

Size II

3WL9 111-0BA06-0AA0

1 1 unit

103

1.530

Size III

3WL9 111-0BA07-0AA0

1 1 unit

103

2.270

Size I

3WL9 111-0BA08-0AA0

1 1 unit

103

1.500

Size II

3WL9 111-0BA04-0AA0

1 1 unit

103

1.850

Size III

3WL9 111-0BA10-0AA0

1 1 unit

103

2.950

Support brackets
For mounting fixed-mounted circuit breakers
on vertical plane, only for
sizes I and II (1 set = 2 units)

3WL9 111-0BB50-0AA0

1 1 unit

103

7.000

3WL9 111-0BA02-0AA0

Contact modules for withdrawable circuit breakers


3-pole
NSE01019

3WL9 111-0BA07-0AA0
4-pole

15

NSE-01022

Support brackets

3WL9 111-0BB50-0AA0
1)

For 60 kA ground short-circuit current, order 2.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/39

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET,
M)

PG

Weight
per PU
approx.
kg

CubicleBUS modules1)
Digital output modules with rotary coding switch,
relay outputs

3WL9 111-0AT26-0AA0

1 1 unit 103

0.240

Digital output modules, configurable, relay outputs

3WL9 111-0AT20-0AA0

1 1 unit 103

0.310

Digital input modules

3WL9 111-0AT27-0AA0

1 1 unit 103

0.240

Analog output modules

3WL9 111-0AT23-0AA0

1 1 unit 103

0.240

Zone Selective Interlocking modules

3WL9 111-0AT21-0AA0

1 1 unit 103

0.240

B
Breaker Data Parameterization, operation, monitoring and
Adapter (BDA) diagnostics of SENTRON circuit breakers
using the local interface; Breaker Data
Adapter, connection cable to the SENTRON
3WL circuit breaker and to the programming
device (e.g. notebook); can be run with Internet
Explorer with JAVA2 VM 1.4.0-01 and higher

3WL9 111-0AT28-0AA0

1 1 unit 103

0.900

3WL9 111-0AT33-0AA0

1 1 unit 103 on req.

3WL9 111-0BC21-0AA0

1 1 unit 103 on req.

3ZS2 311-0CC10-0YA0

1 1 unit 133 on req.

N S E 0 _ 0 1 0 2 3 a

3WL9 111-0AT23-0AA0

Parameterization systems

BDA Plus

Same as BDA, but with additional Ethernet


interface for connection to Ethernet/Intranet/
Internet

Connection cable for connection of BDA Plus


Connection
cables for BDA to terminal X8 of the SENTRON 3WL circuit
Plus
breaker. Required if neither COM15 nor
COM16 nor other external CubicleBUS
3WL9 111-0AT28-0AA0
modules are available, length 2 m.

15

N S E 0 _ 0 1 0 2 4 a

Switch ES
Power parameterization
software

Calibration, operation, monitoring, and diagnostics A


of SENTRON circuit breakers via PROFIBUS
DP; runs under Windows 95, Windows 98,
Windows NT, Windows 2000 and Windows XP
Professional, requires additional PROFIBUS
card e.g. CP5613

Accessories for communications


Preassembled
cables for
CubicleBUS
modules

SENTRON
manuals for
communication
solutions2)

0.2 m long, for connection to SENTRON 3WL


with COM15/COM16

3WL9 111-0BC04-0AA0

1 1 unit 103 on req.

1 m long, for connection to SENTRON 3WL


with COM15/COM16

3WL9 111-0BC02-0AA0

1 1 unit 103

0.050

2 m long, for connection to SENTRON 3WL


with COM15/COM16

3WL9 111-0BC03-0AA0

1 1 unit 103

0.060

2 m long, for connection to SENTRON 3WL


without COM15/COM16

3WL9 111-0BC05-0AA0

1 1 unit 103 on req.

Detailed description of the communication


functions for SENTRON circuit breakers with
PROFIBUS DP. Installation, connection,
commissioning and description of
Switch ES Power and BDA.
German
Token fee 20.
English
Token fee 20.

E20001-A210-P307
E20001-A210-P307-X-7600

Free download from:


http://www.siemens.com/lowvoltage/manuals
Voltage
380 ... 690 V/100 V, class 0.5
transformers,
3-pole, for
SENTRON 3WL
with measurement function
Plus

3WL9 111-0BB68-0AA0

1 1 unit 103 2.600

All communication components, CubicleBUS modules and measurement functions are available for the ETU45B, ETU55B and ETU76B trip units.
1)

Each CubicleBUS module is supplied with a 0.2 m factory-fitted cable to


connect the modules with each other. A longer factory-fitted cable is
required for connection to the circuit breaker.

2)

Manual for MODBUS communication solution available on request.

15/40

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET,
M)

PG

Weight
per PU
approx.
kg

Retrofitting and spare parts


1

B
Retrofit kit for PROFIBUS communications
including COM15, BSS and set of cables for all
SENTRON 3WL circuit breakers with ETU45B,
ETU55B and ETU76Btrip units

3WL9 111-0AT12-0AA0

1 1 unit 103 0.260

3WL9 111-0AT15-0AA0

1 1 unit 103 0.140

Retrofit kit for MODBUS communications


B
including COM16, BSS and set of cables for all
SENTRON 3WL circuit breakers with ETU45B,
ETU55B and ETU76B trip units

3WL9 111-0AT14-0AA0

1 1 unit 103 on req.

COM16
MODBUS
modules

3WL9 111-0AT17-0AA0

1 1 unit 103 0.140

Breaker status
sensor (BSS)

3WL9 111-0AT16-0AA0

1 1 unit 103 0.120

PROFIBUS
retrofit kits

Device

CubicleBus
PROFIBUS DP

COM15 PROFIBUS module


NSE-01025

MODBUS
retrofit kits

3WL9 111-0AT15-0AA0
S45
S43

S42

S40
S44

S41

NSE01026

Measurement
function Plus

For all ETUs except ETU release 2


(voltage transformer required)

3WL9 111-0AT03-0AA0

1 1 unit 103 0.250

Measurement
function Plus

For ETU release 2


(voltage transformer required)

3WL9 111-0AT04-0AA0

1 1 unit 103 0.250

15

3WL9 111-0AT16-0AA0
All communication components, CubicleBUS modules and measurement functions are available for the ETU45B, ETU55B and ETU76B trip units.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/41

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Main circuit connections, fixed mounting


(essential accessory)
3WL9 111-0AL06-0AA0

Specified for each connection


Front-accessible
main circuit
connections,
single hole at top

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AL01-0AA0
3WL9 111-0AL02-0AA0

1
1

1 unit
1 unit

103
103

1.100
1.600

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL03-0AA0
3WL9 111-0AL04-0AA0
3WL9 111-0AL05-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.600
3.500

NSE-01010

Size III, up to 4000 A

3WL9 111-0AL06-0AA0

1 unit

103

6.100

3WL9 111-0AL56-0AA0 Front-accessible

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AL51-0AA0
3WL9 111-0AL52-0AA0

1
1

1 unit
1 unit

103
103

1.000
1.300

B
B

3WL9 111-0AL53-0AA0
3WL9 111-0AL54-0AA0
3WL9 111-0AL55-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.800
3.100
3.000

main circuit
connections,
Size II, up to 2000 A
single hole at bottom Size II, up to 2500 A
Size II, up to 3200 A

15

3WL9 111-0AL14-0AA0

NSE-01011

3WL9 111-0AL64-0AA0

Size III, up to 4000 A

B
B

3WL9 111-0AL56-0AA0

1 unit

103

5.200

Front-accessible
main circuit
connections,
according to
DIN 43673,
double hole at top

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AL07-0AA0
3WL9 111-0AL08-0AA0

1
1

1 unit
1 unit

103
103

1.400
2.000

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL11-0AA0
3WL9 111-0AL12-0AA0
3WL9 111-0AL13-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.400
4.500
4.400

Size III, up to 4000 A

3WL9 111-0AL14-0AA0

1 unit

103

7.800

Front-accessible
main circuit
connections,
according to
DIN 43673,
double hole at bottom

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AL57-0AA0
3WL9 111-0AL58-0AA0

1
1

1 unit
1 unit

103
103

1.300
1.700

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL61-0AA0
3WL9 111-0AL62-0AA0
3WL9 111-0AL63-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.700
3.600

Size III, up to 4000 A

3WL9 111-0AL64-0AA0

1 unit

103

6.400

Rear
vertical
main circuit
connections

Size I1), up to 1600 A

3WL9 111-0AM01-0AA0

1 unit

103

0.500

Size II2), up to 3200 A

3WL9 111-0AM02-0AA0

1 unit

103

2.200

Size III, up to 6300 A

3WL9 111-0AM03-0AA0

1 unit

103

5.000

NSE-01012

3WL9 111-0AM03-0AA0

1)

In the case of vertical connection size I, up to 1000 A one


3WL9 1110AM01-0AA0 vertical connection is required,
up to 1600 A two 3WL9 111-0AM01-0AA0 vertical
connections are required.

2)

In the case of vertical connection size II, up to 2500 A one


3WL9 1110AM02-0AA0 vertical connection is required,
up to 3200 A two 3WL9 111-0AM02-0AA0 vertical
connections are required.

15/42

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Main circuit connections, withdrawable versions


(essential accessory)
Specified for each connection

NSE-01013

3WL9 111-0AN06-0AA0

Front-accessible
main circuit
Size I, up to 1000 A
connections,
Size I, 1250 ... 1600 A
single hole at top or
Size II, up to 2000 A
at bottom
Size II, up to 2500 A
Size II, up to 3200 A
Front-accessible
main circuit
connections,
according to
DIN 43673,
double hole at top or
at bottom

NSE-01014

B
B

3WL9 111-0AN01-0AA0
3WL9 111-0AN02-0AA0

1
1

1 unit
1 unit

103
103

1.000
1.300

B
B
B

3WL9 111-0AN03-0AA0
3WL9 111-0AN04-0AA0
3WL9 111-0AN05-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.800
3.100
3.000

Size III, up to 4000 A

3WL9 111-0AN06-0AA0

1 unit

103

5.200

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AN07-0AA0
3WL9 111-0AN08-0AA0

1
1

1 unit
1 unit

103
103

1.300
1.700

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN11-0AA0
3WL9 111-0AN12-0AA0
3WL9 111-0AN13-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.700
3.600

Size III, up to 4000 A

3WL9 111-0AN14-0AA0

1 unit

103

6.400

3WL9 111-0AN14-0AA0

3-pole for 3 bars

4-pole for 4 bars

Rear
vertical
main circuit
connections

NSE-01017

3WL9 111-0AN41-0AA0

NSE-01015

3WL9 111-0AN23-0AA0

Rear
horizontal
circuit connections

NSE-01016

Connecting flanges

3WL9 111-0AN24-0AA0

Size I

3WL9 111-0AN41-0AA0

1 unit

103

0.700

Size II

3WL9 111-0AN42-0AA0

1 unit

103

on req.

Size III

3WL9 111-0AN43-0AA0

1 unit

103

on req.

Size I

3WL9 111-0AN44-0AA0

1 unit

103

on req.

Size II

3WL9 111-0AN45-0AA0

1 unit

103

on req.

Size III

3WL9 111-0AN46-0AA0

1 unit

103

3.200

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AN15-0AA0
3WL9 111-0AN16-0AA0

1
1

1 unit
1 unit

103
103

0.660
0.870

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN17-0AA0
3WL9 111-0AN18-0AA0
3WL9 111-0AN21-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.150
1.490
2.580

Size III, up to 5000 A

3WL9 111-0AN22-0AA0

1 unit

103

6.380

Size III, up to 6300 A


(3 busbar connection
pieces for 3-pole circuit
breakers)

3WL9 111-0AN23-0AA0

1 unit

103

6.380

Size III, up to 6300 A


(4 busbar connection
pieces for 4-pole circuit
breakers)

3WL9 111-0AN20-0AA0

1 unit

103

on req.

B
Size III, up to 6300 A
(4 busbar connection pieces
for 4-pole circuit breakers)

3WL9 111-0AN10-0AA0

1 unit

103

8.510

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AN32-0AA0
3WL9 111-0AN33-0AA0

1
1

1 unit
1 unit

103
103

0.630
0.770

Size II, up to 2000 A


Size II, up to 2500 A

B
B

3WL9 111-0AN34-0AA0
3WL9 111-0AN35-0AA0

1
1

1 unit
1 unit

103
103

1.020
1.240

Size II, up to 3200 A

3WL9 111-0AN36-0AA0

1 unit

103

2.170

Size III, up to 5000 A

3WL9 111-0AN37-0AA0

1 unit

103

3.860

Size I, up to 1000 A
Size I, 1250 ... 1600 A

B
B

3WL9 111-0AN24-0AA0
3WL9 111-0AN25-0AA0

1
1

1 unit
1 unit

103
103

0.610
0.640

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN26-0AA0
3WL9 111-0AN27-0AA0
3WL9 111-0AN28-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.980
1.020
1.310

Size III, up to 4000 A

3WL9 111-0AN31-0AA0

1 unit

103

2.370

When using front-accessible main circuit connections


(withdrawable circuit breakers) supports are required.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/43

15

Supports
for front and DIN
connecting bars

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Designation

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Conversion sets
For converting fixed-mounted circuit breakers into withdrawable circuit breakers
Guide frames and sliding contact modules must be ordered separately.
Number of poles

Size

3-pole

3WL9 111-0BC11-0AA0

1 1 unit

103

5.100

II

3WL9 111-0BC12-0AA0

1 1 unit

103

5.900

III

3WL9 111-0BC13-0AA0

1 1 unit

103

8.100

3WL9 111-0BC14-0AA0

1 1 unit

103

6.400

II

3WL9 111-0BC15-0AA0

1 1 unit

103

on req.

III

3WL9 111-0BC16-0AA0

1 1 unit

103

on req.

4-pole

Main contact elements

15

You must specify the circuit breaker ID No. when ordering!


Specified for each connection (depending on the number of poles on the circuit breaker, order 3 or 4 units)
Sizes

In max

Up to 1600 A

3WL9 111-0AM90
L1Y1)

1 1 unit

103

on req.

II

Up to 2500 A

3WL9 111-0AM91
L1Y1)

1 1 unit

103

on req.

II

Up to 4000 A

3WL9 111-0AM92
L1Y1)

1 1 unit

103

on req.

III

Up to 6300 A

3WL9 111-0AM93
L1Y1)

1 1 unit

103

on req.

NSE-01021

1)

Order No. is automatically adapted


to the circuit breaker ID number

Please specify the circuit breaker ID No. in plain text when ordering.

15/44

Siemens LV 1 2008

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts
Schematics in as-supplied state

Version

Size

DT Order No.

Price
per PU

PU
PS*
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Withdrawable short-circuits, grounding and bridging units


NSE0_01118

L1 L2 L3

Top and
bottom parts
of system
are shortcircuited
and
grounded

NSE0_01113

3-pole
up to 1600 A I

3WL9 111-0BD01-0AA0

1 unit

103

up to 3200 A II

3WL9 111-0BD03-0AA0

1 unit

103

on req.
40.500

up to 6300 A III

3WL9 111-0BD05-0AA0

1 unit

103

on req.

up to 1600 A I

3WL9 111-0BD02-0AA0

1 unit

103

on req.

up to 3200 A II

3WL9 111-0BD04-0AA0

1 unit

103

on req.

up to 6300 A III

3WL9 111-0BD06-0AA0

1 unit

103

on req.

NSE0_01119

4-pole

(as-supplied state)
N

L1 L2 L3

NSE0_01119

L1 L2 L3

Top part of system is short-circuited and grounded,


infeed from bottom

N S E 0 _ 0 1 1 2 2 a

Top and bottom part of system are short-circuited and grounded


(as-supplied state)

L1 L2 L3
NSE0_01114

N S E 0 _ 0 1 1 2 3 a

NSE0_01115

Withdrawable bridging unit, incoming and outgoing terminal are permanently


connected to each other

* You can order this quantity or a multiple thereof.

L1 L2 L3

L1 L2 L3

NSE0_01121

15

NSE0_01112

NSE0_01113

NSE0_01116

L1 L2 L3

NSE0_01120

L1 L2 L3

NSE0_01117

NSE0_01118

Conversion for the following applications is possible

Bottom part of system is short-circuited and grounded,


infeed from top

Siemens LV 1 2008

15/45

Siemens AG 2008

3WL Air Circuit Breakers

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)


Accessories/spare parts

Options
3WL1

15

Structure of the Order No.


Example

5th position:

Size

Size II

6th and 7th


positions:

Max. rated
circuit breaker
current In max

In max = 2000 A

8th position:

Switching capacity
class

High breaking capacity


"H": 100 kA

9th position:

Electronic trip units

ETU76B with pixel graphics


display ...

10. position:

Electronic trip unit


supplement

... with ground-fault


protection

11th position:

Number of poles

3-pole

12th position:

Installation type

Fixed mounting, main circuit


connections on rear, vertical

They are used as an unambiguous


means of communication for various
purposes:

Offer processing
Selection and configuration
Order processing
Ordering
Order confirmation
Handling warehouse
products
Order processing at the
supply bases
Delivery and shipment
Reporting and planning
Service and warranty

13th position:

Operating
mechanism

Manual operating mechanism


with mechanical closing

14th position:

1st auxiliary switch

Shunt trip unit


AC 50/60 Hz 110 V

15th position:

2nd auxiliary switch Without 2nd auxiliary trip unit

16th position:

Auxiliary switch

An important prerequisite for computerbased order processing is that order


numbers must be structured according
to standardized criteria.

The standardized structure ensures


that only one Order No. has to be
administered for one device.

This saves time and effort during


planning, configuring, ordering
and stock keeping, and consequently
above all it saves costs.

The example opposite explains the


various positions within an
Order No.

2 NO + 2 NC

Accessories: with first order (components are already mounted)


3WL1

Example

Additional accessory components can


be ordered ready-mounted.
These supplements are identified by "-Z".

"Z" with order code

Communications connection
"Standard" + Breaker Status Sensor (BSS)
+ communications module COM15 for
connection to PROFIBUS DP

Even with additional components, one


Order No. is sufficient.

Accessories: for retrofitting (components for subsequent fitting)


Example
3WL9

Additional accessories which are not


intended to be ready-mounted in the
factory, such as spare parts for storage,
can also be ordered separately from
the circuit breaker.

Protective cover for mechanical ON/OFF


without lock

Accessories for retrofitting are identified


by the Order No. stem 3WL9.

Documentation
Operator's guide
Complete set

German/English
French/Italian
Spanish/Portuguese

Order No.
Order No.
Order No.

3ZX18 12-0WL00-0AN0
3ZX18 12-0WL00-0AJ0
3ZX18 12-0WL00-0AL0

Manual
Communication

German
English

Order No.
Order No.

E20001-A210-P307
E20001-A210-P307-X-7600

Free download of documentation from


http://www.siemens.com/lowvoltage/manuals

More information
Up-to-date information on the Internet at:
http://www.siemens.com/sentron

15/46

Siemens LV 1 2008

Delivery time class C


on request
on request

Siemens AG 2008

3WL Air Circuit Breakers

3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)


3- and 4-pole, fixed-mounted versions

Selection and ordering data


For general data see page 15/5.
Size

Max. rated circuit breaker


current
In max

DT

3-pole non-automatic air circuit breakers


Order No.
For Order No. supplements,
see page 15/22

Price
per PU

PS*
PU
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@32-....
3WL12 20-8@@32-....
3WL12 40-8@@32-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

56.000
56.000
64.000

B
B
B

3WL12 10-8@@31-....
3WL12 20-8@@31-....
3WL12 40-8@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

56.000
56.000
85.000

B
B

3WL12 10-8@@33-....
3WL12 20-8@@33-....

1
1

1 unit
1 unit

103
103

56.000
56.000

B
B

3WL12 10-8@@34-....
3WL12 20-8@@34-....

1
1

1 unit
1 unit

103
103

56.000
56.000

Vertical main circuit connection


II
II
II

1000
2000
40001)

Front main circuit connection, single hole


II
II

1000
2000

Front main circuit connection, double hole


II
II

1000
2000

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

AA

Add. price
without

Standard Order No. supplements (for further Order No. supplements, see page 15/22)

Size

Max. rated circuit breaker


current
In max

1AA2

DT

4-pole non-automatic air circuit breakers


Order No.
For Order No. supplements,
see page 15/22

without

Price
per PU

PS*
PU
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@42-....
3WL12 20-8@@42-....
3WL12 40-8@@42-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

67.000
67.000
77.000

B
B
B

3WL12 10-8@@41-....
3WL12 20-8@@41-....
3WL12 40-8@@41-....

1
1
1

1 unit
1 unit
1 unit

103 75.000
103 75.000
103 103.000

B
B

3WL12 10-8@@43-....
3WL12 20-8@@43-....

1
1

1 unit
1 unit

103
103

67.000
67.000

B
B

3WL12 10-8@@44-....
3WL12 20-8@@44-....

1
1

1 unit
1 unit

103
103

67.000
67.000

Vertical main circuit connection


II
II
II

1000
2000
40001)

Front main circuit connection, single hole


II
II

1000
2000

Front main circuit connection, double hole


II
II

1000
2000

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

AA

Add. price
without

Standard Order No. supplements (for further Order No. supplements, see page 15/22)
Manual operating mechanism with mechanical closing

Note:
For voltages over 600 V use the version for 1000 V DC rated voltage:
Order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see "3WL Air Circuit
Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)",
"Options", page 15/23 onwards.
1)

Provisions to dissipate heat must be made on the line side.

2)

For permissible rated short-time current Icw and rated short-circuit switching
capacity Icc for non-automatic air circuit breakers, see Technical Information
LV 1T, "General Data", "Technical Specifications".

* You can order this quantity or a multiple thereof.

1AA2

without

An external overload and short-circuit protection device is available


from the company "mat" for the SENTRON 3WL non-automatic
air circuit breakers.
To be purchased only directly from "mat Maschinen- und Anlagentechnik" (http://www.m-a-t.de).

Siemens LV 1 2008

15/47

15

Manual operating mechanism with mechanical closing

Siemens AG 2008

3WL Air Circuit Breakers

3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)


3- and 4-pole, withdrawable versions
Size

Max. rated circuit breaker


current
In max.

DT

3-pole non-automatic air circuit breakers


Order No.
For Order No. supplements,
see page 15/22

Price
per PU

PS*
PU
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Without guide frames (for guide frames, see page 15/49)


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@35-....
3WL12 20-8@@35-....
3WL12 40-8@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

60.000
60.000
68.000

B
B
B

3WL12 10-8@@36-....
3WL12 20-8@@36-....
3WL12 40-8@@36-....

1
1
1

1 unit
1 unit
1 unit

103 91.000
103 91.000
103 113.000

B
B
B

3WL12 10-8@@37-....
3WL12 20-8@@37-....
3WL12 40-8@@37-....

1
1
1

1 unit
1 unit
1 unit

103 91.000
103 91.000
103 121.000

B
B
B

3WL12 10-8@@38-....
3WL12 20-8@@38-....
3WL12 40-8@@38-....

1
1
1

1 unit
1 unit
1 unit

103 91.000
103 91.000
103 113.000

With guide frames, horizontal main circuit connection


II
II
II

1000
2000
40001)

With guide frames, vertical main circuit connection


II
II
II

1000
2000
40001)

With guide frames, connecting flanges


II
II
II

1000
2000
40001)

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

AA

Add. price
without

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing

Max. rated circuit breaker


current
In max.

15

Size

1AA2

DT

4-pole non-automatic air circuit breakers


Order No.
For Order No. supplements,
see page 15/22

without

Price
per PU

PS*
PU
(UNIT,
SET, M)

PG

Weight
per PU
approx.
kg

Without guide frames (for guide frames, see page 15/49)


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@45-....
3WL12 20-8@@45-....
3WL12 40-8@@45-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

75.000
75.000
82.000

B
B
B

3WL12 10-8@@46-....
3WL12 20-8@@46-....
3WL12 40-8@@46-....

1
1
1

1 unit
1 unit
1 unit

103 109.000
103 109.000
103 136.000

B
B
B

3WL12 10-8@@47-....
3WL12 20-8@@47-....
3WL12 40-8@@47-....

1
1
1

1 unit
1 unit
1 unit

103 109.000
103 109.000
103 146.000

B
B
B

3WL12 10-8@@48-....
3WL12 20-8@@48-....
3WL12 40-8@@48-....

1
1
1

1 unit
1 unit
1 unit

103 109.000
103 109.000
103 136.000

With guide frames, horizontal main circuit connection


II
II
II

1000
2000
40001)

With guide frames, vertical main circuit connection


II
II
II

1000
2000
40001)

With guide frames, connecting flanges


II
II
II

1000
2000
40001)

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic trip unit

AA

Add. price
without

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 15/22)
Manual operating mechanism with mechanical closing

Note:
For voltages over 600 V use the version for 1000 V DC rated
voltage: Order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see "3WL Air Circuit
Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)",
"Options", page 15/23 onwards.
1)

Provisions to dissipate heat must be made on the line side.

2)

For permissible rated short-time current Icw and rated short-circuit switching
capacity Icc for non-automatic air circuit breakers, see Technical Information
LV 1T, "General Data", "Technical specifications".

15/48

Siemens LV 1 2008

1AA2

without

An external overload and short-circuit protection device is available from the company "mat" for the SENTRON 3WL non-automatic air circuit breakers.
To be purchased only directly from "mat Maschinen- und
Anlagentechnik" (http://www.m-a-t.de).

* You can order this quantity or a multiple thereof.

Siemens AG 2008

3WL Air Circuit Breakers

3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)


Accessories/spare parts

Selection and ordering data


Guide frames for DC non-automatic air circuit breakers
Size

Max. rated circuit breaker


current In max

DT

For 3-pole non-automatic air circuit breakers PU


PS*
(UNIT,
Order No.
Price
SET,
M)
(Order No. supplements
per PU

PG

required according to table below)

Weight
per PU
approx.
kg

Front main circuit connection, single hole


II

2000

3WL9 212-3DA@@-@@A1

1 unit

103

31.000

3WL9 212-3DB@@-@@A1

1 unit

103

31.000

B
B

3WL9 212-3DC@@-@@A1
3WL9 212-6DC@@-@@A1

1
1

1 unit
1 unit

103
103

31.000
60.000

B
B

3WL9 212-3DD@@-@@A1
3WL9 212-6DD@@-@@A1

1
1

1 unit
1 unit

103
103

31.000
60.000

1
1

1 unit
1 unit

103
103

31.000
60.000

Front main circuit connection, double hole


II

2000

Horizontal main circuit connection


II
II

2000
4000

Vertical main circuit connection


II
II

2000
4000

Main circuit connection connecting flanges


II
II

2000
4000

B
B

3WL9 212-3DE@@-@@A1
3WL9 212-6DE@@-@@A1

Size

Max. rated circuit breaker


current In max

DT

For 4-pole non-automatic air circuit breakers PU


PS*
(UNIT,
Order No.
Price
SET, M)
(Order No. supplements
per PU

PG

required according to table below)

Weight
per PU
approx.
kg

II

2000

3WL9 212-3EA@@-@@A1

1 unit

103

37.000

3WL9 212-3EB@@-@@A1

1 unit

103

37.000

B
B

3WL9 212-3EC@@-@@A1
3WL9 212-6EC@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

B
B

3WL9 212-3ED@@-@@A1
3WL9 212-6ED@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

B
B

3WL9 212-3EE@@-@@A1
3WL9 212-6EE@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

Front main circuit connection, double hole


II

2000

Horizontal main circuit connection


II
II

2000
4000

Vertical main circuit connection


II
II

2000
4000

Main circuit connection connecting flanges


II
II

2000
4000

Order No. supplements

Add. price

Add. price

3-pole

4-pole

without
x
x
x
x

without
x
x
x
x

without
x
x

without
x
x

0
1

without
x

without
x

Number of auxiliary supply connectors


None
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 15/28

0
1
2
3
4

Type of auxiliary circuit connections


None
With screw connections (SIGUT)
With screwless connection method (tension spring)

0
1
2

Position indicator switches


None
Option 1

Option 2

Operation 1 CO contact,
test 1 CO contact,
disconnected 1 CO contact
Operation 3 CO contacts,
test 2 CO contacts,
disconnected 1 CO contact

Shutters
None

without

without

With shutter, 2 parts, lockable

x = additional price

All other accessory parts must be ordered by specifying "Z"


and the corresponding order code, see "3WL Air Circuit
Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)",
"Options", page 15/23 onwards.

* You can order this quantity or a multiple thereof.

Siemens LV 1 2008

15/49

15

Front main circuit connection, single hole

Siemens AG 2008

3WL Air Circuit Breakers

3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)

15

Notes

15/50

Siemens LV 1 2008

Vous aimerez peut-être aussi