Vous êtes sur la page 1sur 170

TRAINING ON

NOKIA DIGITAL TELECOMMUNICATION SYSTEMS


DMRC

This document and the proprietary information it contains is for the internal
use of Commtel Networks personnel and authorized recipients only

TOPICS

Section - 1
Basics of PDH

Section - 2
Nokia Digital Transmission System

Section - 3
Nokia Management System

Commtel Networks Proprietary

SECTION - 1

Basics of
PDH

Commtel Networks Proprietary

NETWORK LAYERS
Data / information and voice applications
Packet data
based services
(IP, FR,...)

Voice (PSTN, cellular)


and NB data services
(64k & n*64k)
SDH lower order
(LO = VC12/VC3)
layer

ATM layer

SDH higher order


(HO =VC4 path)
layer
Optical
(wavelength)
layer

l - based
connections

Fiber/ duct
layer

Commtel Networks Proprietary

SYSTEM LAYERS

DWDM &
STM- 16

SDH Network
Management
System

PDH Network
Management
System

Backbone Layer

STM- 1/4 Transport Layer


Primary Access Layer
(< 2Mbit/s)
Voice Circuits &
Data Circuits

FIBRE OPTIC CABLE & MICROWAVE


RADIO

Commtel Networks Proprietary

PLESIOCHRONOUS DIGITAL HIERARCHY

Digital Telecommunication System Hierarchies

Plesiochronous Digital Hierarchy (PDH)

Synchronous Digital Hierarchy (SDH)

Plesiochronous Digital Hierarchies

Primary Order - 2 Mbit/s (2,048 Kbit/s)

30 x 64 Kbit/s Channels

Second Order - 8 Mbit/s (8,448 Kbit/s)

4 x 2Mbit/s Tributaries

120 x 64 Kbit/s Channels

Third Order - 34 Mbit/s (34,368 Kbit/s)

16 x 2Mbit/s Tributaries

480 x 64 Kbit/s Channels

Fourth Order - 140 Mbit/s (139,264 Kbit/s)

64 x 2Mbit/s Tributaries

1920 x 64 Kbit/s Channels

Commtel Networks Proprietary

FRAME STRUCTURES
Frame Structure for 2 Mbit/s (ITU-T G.704)

Commtel Networks Proprietary

FRAME STRUCTURES
The frame length is 125 s, comprises 32 time slots, numbered 0...31. Each time slot contains 8 bits. Information relating to channels 1..30 is
inserted in time slots 1...15 and 17...31. Since the frame comprises 256 bits and its repetition rate is 8000 per second, the bit rate of
multiplexed signal is 2048 kbit/s.

Signaling information is transferred in time slot 16. TS16 can be used

TS0 is used for internal data transfer across a 2 Mbit/s

for Channel Associated signaling. When used for CAS, it establishes a

connection (frame alignment, alarms and supervision data). Bits

64 kbit/s bus, which is divided into smaller paths keeping the

2...8 of TS0 are replaced with the frame alignment signal

multiframe alignment signal as a reference point. The multiframe

0011011 in every other frame. Frame alignment is considered

consists of 16 successive frames, numbered 0...15. The multiframe

lost when the bit B2 in the received time slot TS0 is in error three

alignment signal 0000 indicates the beginning of the multiframe.

times in succession in those frames that do not contain frame

These four bits are located in bit locations 1...4 of time slot TS16 in

alignment signal.

frame 0. The signalling bits ai, bi, ci, di (i=1...15) corresponding to


time slots TS1TS15

Commtel Networks Proprietary

PLESIOCHRONOUS DIGITAL HIERARCHY

140 Mbit/s
MUX

140 Mbit/s
MUX

34
Mbit/s
MUX

34
Mbit/s
MUX

8
Mbit/s
MUX

8
Mbit/s
MUX

2
Mbit/s
MUX

2
Mbit/s
MUX

Commtel Networks Proprietary

SECTION - 2

Nokia Digital
Transmission
System

10

Commtel Networks Proprietary

19 NDM SUBRACK T37870.01

19 NDM
SUBRACK
T37870.01

11

Commtel Networks Proprietary

19 NDM SUBRACK T37870.01

The subrack consists of a chassis, a motherboard, a front cover and mounting accessories for use when required.
The subrack chassis is made of stainless steel.
Cabling requires a space of at least 25 mm (or 0.5 U in IEC 19" rack) above and below the subrack.
The subrack must be situated in a weather-proof location, either indoors or in an outdoor cabinet. The subrack can be
installed in 19" (450 mm) racks, see figure below. By using mounting accessories included in the product it can also be
installed in 500 mm ETSI-type racks. Air deflectors can be mounted above and below the subracks as required.
The external battery voltages are connected to the subrack through either a NDM DC unit (NDU), NDM AC/DC Unit (NAU)
or a Rack Power Supply Adapter (RPSA) via an NDM DC Adapter (NDA) in the subrack. Also previous rack specific DC
adapters like Enhanced Power Supply Adapter 19" (EPSA 19") or DC-PSA can be used.

The subrack can house:


16 plug-in units (25 mm/5 T) + 1 Power Unit (39 mm 8T)
Units which comprise only one card and have no special
requirements concerning unit location can be fitted into any of
the four sections of the motherboard.
1U = 44.45 mm
1T = 5.08 mm

12

Commtel Networks Proprietary

19 NDM SUBRACK T37870.01

The motherboard of the subrack can be considered as being split into four sections. Each section consists of four
unit locations.
The section borders are indicated with a dashed line in the figure above.
By using jumpers the sections can be joined to create larger sections.
The subrack allows installation up to 4 x DB2 Multiplexer.
The slot no. 17 is used for NDU/NAU.
It is therefore possible to split the 17- slot motherboard into two, three or four sections. 8 -slot motherboard
can be split into two sections.
13

Commtel Networks Proprietary

19 NDM SUBRACK T37870.01

DB2B with 2 Ch. Units can be

installed in slot 1-4, 5-8, 9-12 & 1316.

DM2+ with 3 Ch. Units can be


installed in slot 1-4, 5-8, 9-12 and
13-15.

14

Commtel Networks Proprietary

19 NDM SUBRACK T37870.01

NDA
T37884.01

NDU
T37882.01

NAU
T37883.01

Power Supply Alternatives


Code

Description

T37882.01

NDM DC Unit (NDU), input voltage 24/48/60 Vdc, max. 10 A.

T37883.01

NDM AC/DC Unit (NAU), input voltage 100-240 Vac, max. 3,6 A. NAU contains two AC/DC modules.

T37884.01

NDM DC Adapter (NDA), input voltage 24/48/60 Vdc, max. 10 A.


Subrack interface for RPSA+RPM+ALM, DC-PSA or EPSA

T37880.01

Rack Power Supply Adapter (RPSA) used as the enclosure for RPM T37881.01and ALM T37884.01

15

Commtel Networks Proprietary

NOKIA DM2 PRIMARY TERMINAL MULTIPLEXER

NOKIA
DIGITAL
TERMINAL
MULTIPLEX
EQUIPMENT
DM2+
TC 21116

16

Commtel Networks Proprietary

NOKIA DM2+ PRIMARY ORDER TERMINAL MULTIPLEXER

Key features
Fulfils the relevant ETSI Open Network Provision requirements for leased line networks.
Comprises a common multiplex unit (MUX) and a variety of tributary units (VF and data).
Allows adding enhanced features simply by adding tributary units, without having to upgrade the multiplex unit's existing
software.
Has a time-division multiplexed bus structure (ITU-T G.704) that allows flexible utilisation of the equipment's transmission
capacity.
Allows each individual VF or data channel to use any 64 kbit/s time slot, several time slots or only part of the capacity of
one time slot. Allocation of time slots is independent of the physical placement of the unit.
With VF channel units, provides an analogue interface with signalling adaptations ranging from subscriber signalling to
various types of junction line signalling. Supports both channel-associated and common channel signalling.
Allows the use of subscriber line testing in subscriber applications.
With data interface units, supports bit rates 0.3 kbit/s 1984 kbit/s in compliance with ITU-T V- and X- series
Recommendations.
All units are managed through the multiplex unit's service interface. Most of the controls and settings can be done without
any jumper modifications.
Software settings are used to set, for example, the following functions:
- Time slot selections
- Level settings
- Impedance settings
- Signalling and data interface parameters
- Loopbacks
Commtel Networks Proprietary
- Alarm
17 functions.

NOKIA DM2+ PRIMARY ORDER TERMINAL MULTIPLEXER

BASIC ARCHITECTURE OF DM2+

Voice
Signalling
Data

VOICE

DATA
Dynacard Bus

Functions of DM2

To Generate Tx Direction Clock Frequency of 2048


Kbit/s

Control the TDM occurring in the channel units

Form the Output Signal Frame

Generate the interface signal complying with ITU-T


Recommendation G.703, as HDB3 line coded.

In the Receive Direction are:

Convert the input signal complying


with ITU-T rec. G.703 to agree with
equipment
logic
sections,
disassembling
the
line
code,
generate the Rx direction clock
signal.

Management
Alarms
Measurement
2048 kbit/s interface
Synchronisation

64 kbit/s data

Data Units Include:


V.28 units
V.24 units
V.11, V.35, X.21 units
G.703 units
G.704 units
ISDN & ILT units

In the Transmit Direction are:

18

MUX

Voice Units Include:


VF units
SUB/EXCH units
SUB/SUB units

Functions of DM2

Synchronise to the incoming signal


frame
Control the demultiplexing occurring
in the channel units

Monitor the error ratio of the


received signal and recognise AIS.

Recognise Alarm Indication Signal


(AIS)

Other Functions of DM2

Handles alarm indications using LEDs & Rack Alarm Lamps

Offers an auxiliary G.703 data interface which can be used, for


example,
9 64 Kbit/s data transfer
9 Common channel signalling

Offers synchronisation interfaces (Tx & Rx clock)

Synchronise Multiplexing unit to external source

Commtel Networks Proprietary

NOKIA DM2+ PRIMARY ORDER TERMINAL MULTIPLEXER

19

Commtel Networks Proprietary

NOKIA DM2+ PRIMARY ORDER TERMINAL MULTIPLEXER


DATA HYBRID OF DM2+

M Interface : Basically used for connecting Service Terminal or NMS to local microprocessor of DM2+
D Interface : Basically used to convey commands, controls to the equipment at the same stations with external 4 wire TMS bus
Data Hybrid : Interconnects M interface, D interface, Microprocessor of local MUX unit & TS0 free bits or TS1-31 which can carry
service channel in the Main signal.

Data Hybrid Not In Use

MI, DI & Service Channel


connected to each other

20

DI to 2M interface

MI, Supervision Data of Service Channel


& DYNACARD Bus interconnected

Commtel Networks Proprietary

NOKIA DM2+ PRIMARY ORDER TERMINAL MULTIPLEXER

21

Commtel Networks Proprietary

DM2+ SERVICE MENU

22

Commtel Networks Proprietary

DM2+ SERVICE MENU

23

Commtel Networks Proprietary

DM2+ SERVICE MENU

24

Commtel Networks Proprietary

DM2+ SERVICE MENU

25

Commtel Networks Proprietary

DM2+ SERVICE MENU

26

Commtel Networks Proprietary

DM2+ SERVICE MENU

27

Commtel Networks Proprietary

DM2+ SERVICE MENU

28

Commtel Networks Proprietary

DM2+ TROUBLE SHOOTING


If the alarm message is

Then.

Power Supply Fault

Check the voltages and ground connections

Installation Error

Check that the units in the configuration have been installed with
software installation. If not, install missing units. Another possible
fault can be found in unit location strappings.

Missing Unit

Check that all the units in the configuration are firmly in their slots

Equipment Reset

Wait a moment alarm typically clears by itself

No incoming 2M signal

Check the incoming main signal cable connection and line system
attenuation.

AIS 2M

Check the far-end transmitter, possible higher order multiplexers


and line system for faults.

Frame Alignment Lost

Check the far-end transmitter, possible higher order multiplexers,


line system, CRC settings and network synchronization for faults.

BER>1E-3

Check the far-end transmitter and line for faults.

CRC Multiframe Lost

Check the CRC setting. Both ends of the point-to-point


connection must have CRC check either ON or OFF.

Far-end Alarm

Check the far-end for alarms and act accordingly.

29

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

NOKIA
DIGITAL
BRANCHING
MULTIPLEX
EQUIPMENT
DB2
TU 24001/2
TU 24010/1
30

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

31

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER


Key features
Comprises of B2 & X2 units and a variety of tributary units (VF and data).
Can be used as Drop/Insert in un-protected or Loop Protected equipment
Cross connection granularity : n x 8 kbit/s
Allows adding enhanced features simply by adding tributary units, without having to upgrade the multiplex unit's existing
software.
Has a time-division multiplexed bus structure (ITU-T G.704) that allows flexible utilisation of the equipment's transmission
capacity.
Allows each individual VF or data channel to use any 64 kbit/s time slot, several time slots or only part of the capacity of
one time slot. Allocation of time slots is independent of the physical placement of the unit.
With VF channel units, provides an analogue interface with signalling adaptations ranging from subscriber signalling to
various types of junction line signalling. Supports both channel-associated and common channel signalling.
With data interface units, supports bit rates 0.3 kbit/s 1984 kbit/s in compliance with ITU-T V- and X- series
Recommendations.
All units are managed through the multiplex unit's service interface. Most of the controls and settings can be done without
any jumper modifications.
Software settings are used to set, for example, the following functions:
- Time slot selections
- Level settings
- Impedance settings
- Signalling and data interface parameters
- Loopbacks
- Alarm functions.
32

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

BASIC ARCHITECTURE OF DB2B

Functions of DB2B
X2 unit:

Voice
Signalling
Data

VOICE

DATA

Voice Units Include:


VF units
SUB/EXCH units
SUB/SUB units

Dynacard Bus

Functions of DB2B

B2

X2

Management
Alarms

Measurement
2048 kbit/s interface
Synchronisation

Data Units Include:


V.28 units
V.24 units
V.11, V.35, X.21 units
G.703 units
G.704 units
ISDN & ILT units

Provide 1x2 Mbit/s interface or


access to time slots via channel units
Realises Timeslot connections to Tx
direction in compliance with
Branching tables

Synchronisation interface for


external clock and provide
equipment clock for other
equipment

Monitor the error ratio of the


received signal and recognise AIS.

B2 unit:

Provide 2 x 2 Mbit/s interfaces (Direction #1 & #2)

Handles alarm indications using LEDs & Rack Alarm Lamps

Perform the settings and control coming via service


interface and command bus

Any direction (1,2 or 3) can be set for In use or Not in use


mode

Controls equipment in fault condition

Control Data Hybrid

Generate Master clock, synchronised to incoming


signal (Rx1..3) or external

Monitor the error ratio of the received signal and recognise AIS.

33

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

34

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER


Functional Block Diagram Of DB2B

35

Commtel Networks Proprietary

NOKIA DB2B CONFIGURATION OPTIONS


UN-PROTECTED DB2B

DB2B with CH Units


Channels can be branched from
both directions of Main branch
without limitation. The types of
branching are:

36

Through-connection between
interfaces 1 & 2

Arrangement of channels
between interfaces 1 & 2

Branching in direction 1-3

Branching in direction 2-3

VF common channels

Digital common channels

Commtel Networks Proprietary

NOKIA DB2B CONFIGURATION OPTIONS

37

Commtel Networks Proprietary

NOKIA DB2B CONFIGURATION OPTIONS

38

Commtel Networks Proprietary

NOKIA DB2B CONFIGURATION


DB2LP

The Loop Protection philosophy involves developing a network architecture in the form of a
physical loop, and being able to dynamically branch channels in either a clockwise or
anticlockwise direction so as to avoid equipment failures or Fibre break in one direction
and maintain high system availability.
The DB-2LP dynamically selects an available path through the loop configuration.
Loop Protection is provided on 64kbps channel level.
The protection is channel specific and, depending on the transmission capacity available
and the use of the connections, concern all or some of the channels in the system.

39

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

B0 (1 2)
B1 (1 3)

B2 (2 3)
S2
C2
S0
C0

Y1/2/3
M1/2

40

Commtel Networks Proprietary

S1
C1

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

DATA HYBRID OF DB2B


M Interface : Basically used for connecting Service Terminal or NMS to local microprocessor of DM2+
D Interface : Basically used to convey commands, controls to the equipment at the same stations with external 4
wire TMS bus
Data Hybrid : Interconnects M interface, D interface, Microprocessor of local MUX unit & TS0 free bits which can carry
service channel in the Main signal.

41

The Data Channels interfaces are formed by


free bits b5-b8 of Timeslot 0 of each 2M
directions.

Data channel operates on sampling principle at 4,8,


or 16 KHz, depending on the number of bits used.

Usage and the sampling rate are set individually for


each 2M data channel interface.

DH ON enables both DI & MI permanently

Commtel Networks Proprietary

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

42

Commtel Networks Proprietary

MI : Maintenance Interface

DI : Data Channel

PA1/PA2: Programmable
Alarm Outputs

RLSS: Received 2.048


Mbit/s Signal, 120 ohm

RLSU: Received 2.048


Mbit/s Signal, 75 ohm

RLSC: Received 2.048


Mbit/s signal Common

RLSG: Received 2.048


Mbit/s signal Ground

TLSS: Transmitted 2.048


Mbit/s Signal, 120 ohm

TLSU: Transmitted 2.048


Mbit/s Signal, 75 ohm

TLSC: Transmitted 2.048


Mbit/s signal Common

TLSG: Transmitted 2.048


Mbit/s signal Ground

NOKIA DB2 PRIMARY DROP/INSERT MULTIPLEXER

43

Commtel Networks Proprietary

MI : Maintenance Interface

DI : Data Channel

PA1/PA2: Programmable
Alarm Outputs

RLSS: Received 2.048


Mbit/s Signal, 120 ohm

RLSU: Received 2.048


Mbit/s Signal, 75 ohm

RLSC: Received 2.048


Mbit/s signal Common

RLSG: Received 2.048


Mbit/s signal Ground

TLSS: Transmitted 2.048


Mbit/s Signal, 120 ohm

TLSU: Transmitted 2.048


Mbit/s Signal, 75 ohm

TLSC: Transmitted 2.048


Mbit/s signal Common

TLSG: Transmitted 2.048


Mbit/s signal Ground

DB2 SERVICE MENU

44

Commtel Networks Proprietary

DB2 SERVICE MENU

45

Commtel Networks Proprietary

DB2 SERVICE MENU

46

Commtel Networks Proprietary

DB2 SERVICE MENU

47

Commtel Networks Proprietary

DB2 SERVICE MENU

48

Commtel Networks Proprietary

DB2 SERVICE MENU

49

Commtel Networks Proprietary

DB2 SERVICE MENU

50

Commtel Networks Proprietary

DB2 SERVICE MENU

51

Commtel Networks Proprietary

DB2 TROUBLE SHOOTING


If the alarm message is

Then.

Power Supply Fault

Check the voltages and ground connections

Installation Error

Check that the units in the configuration have been installed with
software installation. If not, install missing units. Another
possible fault can be found in unit location strappings.

Missing Unit

Check that all the units in the configuration are firmly in their
slots

Equipment Reset

Wait a moment alarm typically clears by itself

No incoming 2M signal

Check the incoming main signal cable connection and line


system attenuation.

AIS 2M

Check the far-end transmitter, possible higher order


multiplexers and line system for faults.

Frame Alignment Lost

Check the far-end transmitter, possible higher order


multiplexers, line system, CRC settings and network
synchronization for faults. Check also the allocation of MCB and
LCB and buffers. The main branch of Master must be in buffered
mode.
Check the far-end transmitter and line for faults.

BER>1E-3
CRC Multiframe Lost

Check the CRC setting. Both ends of the point-to-point


connection must have CRC check either ON or OFF.

Far-end Alarm

Check the far-end for alarms and act accordingly.

Fault in Tx

Check the outgoing signalling bits-forbidden combination


(0000) detected.

Run Diagnostics Test

Run the RUNTEST (TOP,9,7) and check the handbook for


meaning of error code

52

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

NOKIA
Dynamic Node
Equipment
DN2

53

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

54

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

55

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

56

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

57

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

58

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

59

Commtel Networks Proprietary

NOKIA DN2 Dynamic Node Equipment

60

Commtel Networks Proprietary

DN2 Service Menus

61

Commtel Networks Proprietary

DN2 Service Menus

62

Commtel Networks Proprietary

DN2 Service Menus

63

Commtel Networks Proprietary

DN2 Service Menus

64

Commtel Networks Proprietary

DN2 Service Menus

65

Commtel Networks Proprietary

DN2 Service Menus

66

Commtel Networks Proprietary

DN2 Service Menus

67

Commtel Networks Proprietary

DN2 Service Menus

68

Commtel Networks Proprietary

DN2 Service Menus

69

Commtel Networks Proprietary

DN2 Service Menus

70

Commtel Networks Proprietary

DN2 Service Menus

71

Commtel Networks Proprietary

DN2 Service Menus

72

Commtel Networks Proprietary

DN2 Service Menus

73

Commtel Networks Proprietary

NOKIA CHANNEL UNITS

Data Interface Unit : DIU 0.6..19.2k, V.28/V.11

Subscriber/Subscriber Channel unit : SUB/SUB

Data Interface Unit : DIU 64k, X.21

Voice Frequency Channel unit : VF E&M

Subscriber/Exchange Channel unit :


SUB/EXCH

74

Commtel Networks Proprietary

NOKIA CHANNEL UNITS

DATA INTERFACE
UNIT
DIU 19.2K,
V.28/V.11
TU 24021.01

75

Commtel Networks Proprietary

Data Interface Unit : DIU 19.2k, V.28/V.11 - TU 24021.01


DIU 19.2k, V.28 CHANNEL UNIT : TU 24021
The 5T size card consists of 8 x V.28/V.11, Asynchronous interfaces.
The DIU channels are configurable for different Async. data rates such as 600, 1200, 2400, 4800, 9600, 19200
bit/s.
The DIU channel uses 1,2,4 or 8 bits of timeslot for data communication depending upon the type of coding and
data rate.
Each card has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
The DIU card has 2 Mbit/s bus interface for establishing connection to DM2, DB2B or DN2 equipment.
All the channels are fully programmable for following characteristics:
9 Channel Use
9 Channel time slot allocation 1-15 & 17-31
9 Operating Mode Selection: Sampling, Sampling & Filtering, Transition Coding
9 Channel Loopbacks
9 Loopback Timeouts
9 Monitoring of data
The typical applications are:
9 SCADA RTU & Master connectivity
9 Data communication for other type of applications
76

Commtel Networks Proprietary

Data Interface Unit : DIU 19.2k, V.28/V.11 - TU 24021.01

77

8 x V.28/V.11, Asynchronous channels

Tx, Rx & Gnd signals

Operating Voltage: -20 -72 VDC

Power Consumption < 4 W

Commtel Networks Proprietary

Data Interface Unit : DIU 19.2k, V.28/V.11 - TU 24021.01

OPERATING MODES

Use Bit masking to define the bits to be used for data


transmission (mask with 1 for using and 0 for not using).
Bit mask is ANDed with actual data bits.

CCITTR.111

78

Commtel Networks Proprietary

Data Interface Unit : DIU 19.2k, V.28/V.11 - TU 24021.01

LOOPBACKS

Loop to Interface (L1): Data coming from V.28 interface looped back to interface

Loop to equipment (L2): Data coming from designated timeslot of the channel is looped back to MUX.

79

Commtel Networks Proprietary

DIU 19.2k, V.28: SERVICE MENU

80

Commtel Networks Proprietary

DIU 19.2k, V.28: SERVICE MENU

81

Commtel Networks Proprietary

DIU 19.2k, V.28: SERVICE MENU

82

Commtel Networks Proprietary

TROUBLE SHOOTING OF DIU 19.2K V.28 UNIT

Power Supply Fault

Step 1:

- Check the incoming voltage level and the unit operating voltages (TOP,7,9,u,1..). Check for abnormality in
measurement.
- Calibrate the voltages.

Step 2:

If the above measures do not solve the problem. Remove the unit and re-inset back into designated slot

Step 3:

If the problem still persists, then there might be possibility of power supply section failure.

Channel fault / Memory Fault

Step 1:

Conduct the testing of channels and memory using ST menu TOP,9,9,u,

Forced Indication

Step 1:

- Check that either RED or ORANGE LEDs are not FORCED ON.
- Using ST menu TOP,5,9,u,2,1 the LEDs can be normalised which should remove alarm

83

Commtel Networks Proprietary

Nokia Data Interface Units

DATA INTERFACE UNIT


DIU X.21

84

Commtel Networks Proprietary

Data Interface Unit : DIU X.21


DIU X.21 CHANNEL UNIT :
The 5T size card consists of 5 x X.21, Synchronous interfaces (DCE/DTE)
The DIU channels supports to operate in DCE & DTE mode with configurable for different Sync. data rates of 48, 56 & 64
kbit/s.
The DIU channel control signals are transferred in Timeslot 16. The control signals received from far end (in TS16) can be
filtered for 12 ms.
The Synchronisation for PMUX can be generated from incoming 48/56/64 kbit/s clock provided by the terminal equipment.
Each card has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
The DIU card has 2 Mbit/s bus interface for establishing connection to DM2, DB2B or DN2 equipment.
All the channels are fully programmable for following characteristics:
9
9
9
9
9

Channel Use
Channel time slot allocation 1-15 & 17-31
Operating Mode Selection: DCE/DTE, Inverted/Not Inverted Tx Clk.
Channel Loopbacks
Loopback Timeouts

The typical applications are:


9 Router X.21 Serial WAN interface extension
9 SCADA RTU & Master connectivity
9 Data communication for other type of applications
85

Commtel Networks Proprietary

Data Interface Unit : DIU X.21

86

Commtel Networks Proprietary

The DATU-E block handles functions


associated with data transmission on five
channels.
9

It picks up from the databus the data


out of time slot allocated for the data
channel concerned, eight data bits at a
time and places data on X.21 line
interface at designated rate (48/56/64
kbit/s)

The data is received from X.21 line and


transmitted in octets into the time slot
allocated for the data channel
concerned.

In DCE mode, contra direction, the


timing 114 & 115 are extracted from
T2M & R2M signals,respectively.

In DTE mode, co direction data received


from DTE is synchronised with timing
received from DTE. Buffering (BUF1 &
BUF2) is used for correction of deviation
between external & internal timing
(local clock slips). This deviation is
corrected by slips in buffer.

The SBUIP circuit transfers control signal


between terminal and the MUX unit. The
processor reads states of signal from SBUIP
circuit at certain intervals and transfers to

Data Interface Unit : DIU, X.21

LOOPBACKS

Loop to Interface : Data coming from X.21 interface looped back to interface

Loop to equipment : Data coming from designated timeslot of the channel is looped back to MUX.

INTERFACE LOOPBACK

87

EQUIPMENT LOOPBACK

Commtel Networks Proprietary

DIU X.21 Service Menu

88

Commtel Networks Proprietary

DIU X.21 Service Menu

89

Commtel Networks Proprietary

DIU X.21 Service Menu

90

Commtel Networks Proprietary

Trouble Shooting Of DIU X.21 Unit

Power Supply Fault


Step 1:

- Check the incoming voltage level and the unit operating voltages (TOP,7,9,u,1..). Check for abnormality in
measurement.
- Calibrate the voltages (TOP 9,9,u,1..).

Step 2:

If the above measures do not solve the problem. Remove the unit and re-inset back into designated slot

Step 3:

If the problem still persists, then there might be possibility of power supply section failure.
No incoming 64 k signal

This alarm is due to missing received signal or the received clock signal is missing

Step 1:

Check that data cable is connected properly or DTE device is not in power off condition.

Buffer overflow (underflow)


This alarm appears when slip alarm limit has exceeded.

Step 1:

- Ensure that slips are within allowed limits.


- Disable alarm using ST menu TOP,6,9,u,3,n,4,1,1/2,2 Tx/Rx buffer slip alarm disable
Forced Indication

Step 1:

- Check that either RED or ORANGE LEDs are not FORCED ON.
- Using ST menu TOP,5,9,u,1 the LEDs can be normalised which should remove alarm
91

Commtel Networks Proprietary

SUBSCRIBER EXCHANGE CHANNEL UNIT

SUBSCRIBER EXCHANGE
CHANNEL
UNIT
SUB/EXCH
TU 21216

92

Commtel Networks Proprietary

Subscriber/Exchange Channel unit : SUB/EXCH

SUBSCRIBER EXCHANGE CHANNEL UNIT : TU 21216


The 5T size card consists of 6 x 2W FXO (Foreign Exchange Office) interfaces.
The application is to extend the Analogue extension of PABX to far end.

Each card has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
The SUB/EXCH card has 2 Mbit/s bus interface for establishing connection to DM2, DB2B or DN2 equipment.

All the channels are fully programmable for following characteristics:


9 Channel Use
9 Channel time slot allocation 1-15 & 17-31
9 Level setting
9 Metering Signalling Logic
93

Commtel Networks Proprietary

Subscriber/Exchange Channel unit : SUB/EXCH

KEY FEATURES
Impulse (Rotary)/ DTMF dialling
Ground Key function regeneration
Forwarding of Polarity Reversal information to SUB/SUB unit
Loop forwarding to SUB/SUB unit
Ringing detection
Metering (12 KHz)
Protection against hazardous voltages (mains voltages and residual voltages due to lightning) by a protection
circuitry
Compliant to ITU-T G.712, G.713 & Q.552 with some exceptions
Minimum Voltage (the Criterion voltage at exchange) : - 43 VDC

94

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

95

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

96

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

97

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

98

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

99

Commtel Networks Proprietary

SUB/EXCH SERVICE MENU

SUB/EXCH Default Settings

100

Commtel Networks Proprietary

TROUBLE SHOOTING OF SUB/EXCH UNIT

AIS Timeslot 16 alarm

Step 1:

Check which channel receives this alarm.

Step 2:

Ensure that the timeslot allocated for the channel is dropped from Dir. 1 or 2 in case of DB.

Step 3:

Ensure that corresponding channel at far end station is ON and the timeslot allocated for the channel is dropped
from Dir. 1 or 2 in case of DB.

Blocked from Use or Timeslot Queuing (qn)

Step 1:

Check that same Timeslot is not allocated to other channel of same unit or channels of other units

Step 2:

Allocate another vacant timeslot. In case of DB-2B, the dropped timeslot can be different from Dir. 1 or 2.

Sometimes this alarm appears immediately after allocation of timeslot, however in case of non-conflict, the alarm
clears automatically.

101

Commtel Networks Proprietary

TROUBLE SHOOTING OF SUB/EXCH UNIT

Power Supply Fault

Step 1:
Check the criterion voltage (B1) which should be > -43 VDC.

Generally incoming supply voltage from charger is used as Criterion voltage source and hence check the incoming
supply voltage.
Step 2:
If the voltage is correct then calibrate the B1 voltage using ST/MSTE (TOP,7,9,u,1,2,1)

Fault in Current Loop

Step 1:
Ensure that DC current in subscriber loop is not excessive.

Equipment Fault
- This indicates fault in EEPROM memory or Unit Power Supply.

102

Commtel Networks Proprietary

NOKIA CHANNEL UNITS

SUBSCRIBER SUBSCRIBER
CHANNEL
UNIT
SUB/SUB
TU 21206

103

Commtel Networks Proprietary

Subscriber/Subscriber Channel unit : SUB/SUB

SUBSCRIBER SUBSCRIBER CHANNEL UNIT : TU 21206


The application is:
The 5T size card consists of 6 x 2W FXS (Foreign Exchange Subscriber) interfaces.
9

To drop the Analogue extension of PABX with SUB/EXCH at far end

To drop the Analogue extension of PABX via 2.048 Mbit/s link to Digital Exchange

104

Commtel Networks Proprietary

Subscriber/Subscriber Channel unit : SUB/SUB

To setup Hot Line connectivity between two stations

Each card has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
The SUB/SUB card has 2 Mbit/s bus interface for establishing connection to DM2, DB2B or DN2 equipment.
The SUB/SUB unit requires external ringing supply from RING GENERATOR for extending ring to subscriber
telephone
unit.
All the channels are fully programmable for following characteristics:
9 Channel Use
9 Channel time slot allocation 1-15 & 17-31
9 Level setting
9 Metering Signalling Logic

105

Commtel Networks Proprietary

Subscriber/Subscriber Channel unit : SUB/SUB

KEY FEATURES
Impulse (Rotary)/ DTMF dialling
Ground Key function regeneration
Forwarding of Polarity Reversal information to SUB/SUB unit
Ring forwarding to subscriber telephone unit
Metering (12 KHz)
Protection against hazardous voltages (mains voltages and residual voltages due to lightning) by a protection
circuitry
Compliant to ITU-T G.712, G.713 & Q.552
Minimum Voltage (the Criterion voltage at exchange) : - 43 VDC

106

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

107

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

108

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

109

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

110

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

111

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

112

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

113

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

114

Commtel Networks Proprietary

SUB/SUB SERVICE MENU

115

Commtel Networks Proprietary

TROUBLE SHOOTING OF SUB/SUB UNIT

AIS Timeslot 16 alarm

Step 1:

Check which channel receives this alarm.

Step 2:

Ensure that the timeslot allocated for the channel is dropped from Dir. 1 or 2 in case of DB.

Step 3:

Ensure that corresponding channel at far end station is ON and the timeslot allocated for the channel is dropped
from Dir. 1 or 2 in case of DB.

Blocked from Use or Timeslot Queuing (qn)

Step 1:

Check that same Timeslot is not allocated to other channel of same unit or channels of other units

Step 2:

Allocate another vacant timeslot. In case of DB-2B, the dropped timeslot can be different from Dir. 1 or 2.

Sometimes this alarm appears immediately after allocation of timeslot, however in case of non-conflict, the alarm
clears automatically.

116

Commtel Networks Proprietary

TROUBLE SHOOTING OF SUB/SUB UNIT

Power Supply Fault

Step 1:

Check the criterion voltage (B1) which should be > -43 VDC.

Generally incoming supply voltage from charger is used as Criterion voltage source and hence check the incoming
supply voltage.
Step 2:

If the voltage is correct then calibrate the B1 voltage using ST/MSTE (TOP,7,9,u,1,2,1)

Installation Error

- This alarm is due to software incompatibility with hardware.


Step 1:

Ensure that software version is compatible with hardware.

Step 2:

Ensure that two units have not been accidentally inserted into each others slot in subrack.

Equipment Fault
- This indicates fault in EEPROM memory or Unit Power Supply.

117

Commtel Networks Proprietary

RING GENERATOR UNIT

RING GENERATOR
UNIT
RING GEN
T37885.02

118

Commtel Networks Proprietary

RING GENERATOR UNIT

Ring Generator : T37885.01/2


The 5T size card consists provides ringing voltage to subscriber telephone units.
The Ring generator is interfaced with SUB/SUB unit via subrack backplane.
The Ring Generator is activated by REN signal from SUB/SUB signal or alternatively RING generator can be kept ON
continuously by setting Keyed jumper.
The Ring generator output voltage is 75 Vrms or 90 Vrms, selectable by jumper setting.
The Ring generators ringing frequency can be selected as 25 or 50 Hz as shown below:

119

Commtel Networks Proprietary

NOKIA CHANNEL UNITS

VOICE FREQUENCY
CHANNEL
UNIT
VF E&M
TU 21236.00

120

Commtel Networks Proprietary

Voice Frequency Channel unit : VF E&M

VF E&M CHANNEL UNIT : TU 21236.00


The 5T size card consists of 8 x VF 2W or 4W interfaces.
Each card has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
Each VF interface has one/two E&M DC signalling channel.
The VF card has 2 Mbit/s bus interface for establishing connection to DM2, DB2B or DN2 equipment.
All the channels are fully programmable for following characteristics:
9 Channel Use
9 Channel time slot allocation 1-15 & 17-31
9 Two wire or Four wire VF interface selection
9 Level setting, separately for two wire or four wire interfaces
9 Signalling Logic
9 Balance impedance
The typical applications are:
9 Extension of PABX VF trunks
9 Legacy voice interface 2W / 4W
9 Omnibus Conference communication channel
121

Commtel Networks Proprietary

VF E&M SERVICE MENU

122

Commtel Networks Proprietary

VF E&M SERVICE MENU

123

Commtel Networks Proprietary

VF E&M SERVICE MENU

124

Commtel Networks Proprietary

VF E&M SERVICE MENU

125

Commtel Networks Proprietary

VF E&M SERVICE MENU

126

Commtel Networks Proprietary

TROUBLE SHOOTING OF VF E&M UNIT

AIS Timeslot 16 alarm

Step 1:
Check which channel receives this alarm.

Step 2:
Ensure that the timeslot allocated for the channel is dropped from Dir. 1 or 2 in case of DB.

Step 3:
Ensure that corresponding channel at far end station is ON and the timeslot allocated for the channel is dropped
from Dir. 1 or 2 in case of DB.
Blocked from Use or Timeslot Queuing (qn)

Step 1:
Check that same Timeslot is not allocated to other channel of same unit or channels of other units

Step 2:
Allocate another vacant timeslot. In case of DB-2B, the dropped timeslot can be different from Dir. 1 or 2.

Sometimes this alarm appears immediately after allocation of timeslot, however in case of non-conflict, the alarm
clears automatically.
127

Commtel Networks Proprietary

SECTION - 3

Nokia
Management
System

128

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

NMS/10 BASIC CONCEPTS

Transmission business is very fragmented

9 A lot of different kind of nodes and interface cards


9 New versions and variants are released very frequently

NMS/10 manages all Nokia transmission equipment, and selected 3rd party nodes

Very flexible System Architecture

Affordable and easy to use PC based Management tool

Allows Fast Implementation of Networks

Scalable Solutions

Uses Industry standard Interfaces (SNMP)

Ability to manage the DCN (FM)

129

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

NMS/10 - COMPETITIVE ADVANTAGES


FULL EMS FUNCTIONALITY :

SIMPLE

Entry level network management


system for small and medium size
transmission networks - fast rollout
FM, CM and PM for all Nokia
transmission elements

Easy to install, commission and use


(familiar Windows environment) Training
investments minimised

MODULAR
ARCHITECTURE

SCALABILITY
-Build as you go

Fast and easy integration of


management support for new
network elements as they are
released

Safe investment: Nokia develops


NMS/10 system for future

PCPC-BASED
Reliable and secure well-known operating environment
Price effectiveness
Fast delivery - standard PC can be used
Cheap system support & low training costs

130

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

NOKIA NMS/10 C6.1 : HP OPENVIEW GUI

IP
IPnetworks
networks

Transmission
Transmission
networks
networks

Integrated management of transmission and IP networks using the


platform from worldwide market leader in network management platforms

131

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

Distributed system:

9 Management Consoles
9 Management Station

NMS/10
Management
Console(s)

TCP/IP

9 Management Agents

Multipurpose Agents are interfaces to the managed

NMS/2000

networks

Management Station includes all centralised functions (DB,

UI)

NMS/10
Management Station

Management Station can be accessed remotely using

Management Consoles

SNMP

Remote use of Node Managers requires WTS - node

LAN TCP/IP

managers are to be installed into agents or a separate server

Internet Access to Agents and Alarms

NMS/10
Management
Agent(s)

SDH

132

Commtel Networks Proprietary

SDH
Radio

PDH

XXX

NOKIA NMS/10 C6.1


NMS/10 Main Station

Proprietary management interfaces


converted to open, standard SNMP
interface

9 Hide differences between different


network element interfaces

Agents can reside in the same PC

Agent tasks:

9 Collect alarms from network elements


9 Store the data in the Agent MIB

SNMP

9 Pass alarms to NMS using SNMP traps

LAN

Node Managers to configure nodes can be


put on the same PC or in a separate machine.

DCN
Adaptor

MF
Q1 Bus
PDH
NODES

133

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

All in one PC solution

9 NMS/10 System Frame and HP


OpenView NNM

Q3

Synfonet

9 Node managers in the same PC

9 Use the same platform to


manage SNMP managed IP

SNMP

products

Note:

DCN
Adaptor

MF
Up to 3 x MF's
with a total capacity
of 5000 PDH/PRE
NE's of 9000 FE's

134

Q1
PDH
PRE

Up to 200 FEs per


bus and upto 600
FEs per DCN adapters
and
total 6 DCN per
one System Frame
Commtel Networks Proprietary

- MF is always a separate industrial


PC.

- SDH Synfonet management


requires a dedicated PC

NOKIA NMS/10 C6.1

When the network grows, new


agents can be added to the
system,Because of the new network
regions, new management sites may
also be needed:

IP

9 NMS/10 can be accessed remotely


9 Other NMS can share the same

SNMP

agents

File Mode Hide Utils Window

View Tampere.fin

IP

Mode Alarms

IP network components can be


managed using the same platform

SNMP

Capacity of the system:

SNMP

Q3
Synfonet

135

NNP
SDH
Radio

Q1
PDH
PRE

Q3
Synfonet

Commtel Networks Proprietary

9000 Q1 FE (3 full MFs)

Over 3500 Q1 FE (6 DCN)

300 SYNFONET NEs (100/agent)

100 SDH Radios

NOKIA NMS/10 C6.1

Upwards:
Open, industrial standard SNMP
interface from Agents to any NMS
supporting SNMP

Other NMS

9
File Mode Hide Utils Window

View

PDH
PRE
Synfonet

136

NMS/10

Tampere.fin

Mode Alarms

SDH
Radio

Commtel Networks Proprietary

Downwards: Management of
SNMP managed devices (e.g.
DCN Components)

NOKIA NMS/10 C6.1


Interfaces to other systems
- Alarm spooling
- SNMP
- Email
MW
Radios
NMS/10

SDH

Mediation
Device
PDH
PRE
Current alarm view
Database
Alarm History
137

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Root

138

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Nokia

139

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Agents

140

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Equipments

141

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Sup. Buses

142

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


C.

Alarms

143

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


C.

Alarms

144

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


H.

Alarms

145

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


H.

Alarms

146

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Alarm
Purge

147

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


Alarm
Filter

148

Commtel Networks Proprietary

NOKIA NMS/10 C6.1


NODE MGR

149

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

150

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

151

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

152

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

153

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

154

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

155

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

156

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

157

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

158

Commtel Networks Proprietary

NOKIA NMS/10 C6.1

PM
PMdata
datacollected
collectedfrom
fromSDH,
SDH,PDH,
PDH,MW
MWand
andNT
NT
elements
elementscan
canbe
bepost-processed
post-processedusing
usingexternal
externaltools
tools
DM2/1 ST4

MW
Radios

6
4
2

SDH

NMS/10

98-04-05
00:10:53
01.066.00 DF140/2 ST1
02.0c9.00 DF140/1 ST2
02.0c9.00 DF140/1 ST2
02.0c9.00 DF140/1 ST2
02.0c9.00 DF140/1 ST2
02.0c9.00 DF140/1 ST2
03.191.00 DM2/1 ST4
01.067.00 CO140 ST1
02.0cb.00 CO140 ST2
03.191.00 DM2/1 ST4
01.067.00 CO140 ST1
01.067.00 CO140 ST1
01.067.00 CO140 ST1
01.067.00 CO140 ST1
01.067.00 CO140 ST1
01.067.00 CO140 ST1
01.067.00 CO140 ST1
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
02.0cb.00 CO140 ST2
03.191.00 DM2/1 ST4
01.068.00 DM140 ST1
01.068.00 DM140 ST1
01.068.00 DM140 ST1
01.068.00 DM140 ST1
01.068.00 DM140 ST1
02.0cc.00 DM140 ST2

Mediation
device
PDH
PRE

159

Commtel Networks Proprietary

98-04-05
00:15:53
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM
TRANSM

DF140_g821
DF140_g821
DF140_g821
DF140_g821
DF140_g821
DF140_g821
DM2_errors
CO140_resets
CO140_resets
DM2_errors
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
CO140_g821
DM2_errors
DM140_g821
DM140_g821
DM140_g821
DM140_g821
DM140_g821
DM140_g821

CRC

98-04-05
00:20:53
Optical DM
Optical TT
Optical AT
Optical ES
Optical SES
Optical DM
2M
FAE
Cpu
resets
Cpu
resets
2M
FAW
140M TT
140M AT
140M_SAT_A
140M_SAT_B
140M ES
140M SES
140M DM
140M TT
140M AT
140M_SAT_A
140M_SAT_B
140M ES
140M SES
140M DM
2M
CRC
140M TT
140M AT
140M ES
140M SES
140M DM
140M TT

98-04-05
00:25:53

98-04-05
00:30:53

15min 98-04-05 00:10:52 1.17549e-038


900
900
15min 98-04-05 00:10:52 1.17549e-038
15min 98-04-05 00:10:52 1.17549e-038
15min 98-04-05 00:10:52 1.17549e-038
15min 98-04-05 00:10:52
0
15min 98-04-05 00:10:52
13
15min 98-04-05 00:10:52
13
15min 98-04-05 00:10:52
0
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53
0
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53
899
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53 1.17549e-038
15min 98-04-05 00:10:53
899

15min 98-04-05 00:10:52


FAE15min
FAW
98-04-05 00:10:52

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

NOKIA NMS COMPONENTS

TRANSMISSION MANAGEMENT SYSTEM


ADAPTOR
TMS
TC 21710.01

160

Commtel Networks Proprietary

TMS AD : TC 21710.01

The 5T size TMS Adaptor forms an integral part of the Nokia Transmission Management System. It provides a
means for the logical connection of multiple bus masters (i.e. Service Terminal, TMC, PC-TMC) to a single TMS
Service Bus.
The TMS Adaptor has three ports viz. Port A , B and C. Both Port A & Port B are used for connection of Bus
Master to TMS Service bus (MI) via Port C.
The basic operation of this equipment involves the reception and buffering of incoming commands from the bus
masters (Ports A & B), retransmission of these messages (in order of reception) onto the service bus (Port C), waiting
for a reply, then forwarding the reply to the appropriate bus master.
The TMS adaptor can connect up to maximum 32 Network Elements on Port C service bus. Port C speed can be
higher than Port A & Port B & more than 1200 baud.
The TMS adaptor has on-board DC/DC convertor & operates in range of 20 VDC to 72 VDC.
The TMS adaptor is fully programmable for following characteristics:
9 Port Type : TMC or ST
9 Port Interface Type : V.11 or V.28 or RS-485
9 Port Speeds
9 Port C Timeouts
9 TMS address and NE count

161

Commtel Networks Proprietary

TMS AD : TC 21710.01

A1

Port A :
3 x V.11
or

A2

2 x V.11 + 1 x V.28

A3

Port B :
2 x V.11 + 1 x RS-485

A4

or
2 x V.11 + 1 x V.28

B1

Port A : TMC / NMS

Port B : ST

At a time only one BUS


Master in Port A & B

TMS Adaptors must not


be cascaded as this can
cause response delays
which are longer than the
Service Terminal or TMC
timeout.

B2
B3
B4

162

Commtel Networks Proprietary

TMS AD : TC 21710.01
NMS/10 PC

TMS Adaptor

Port
A

NMS REQ.

Service
Terminal/LCT

163

ST REQ.

Port
C

NE REPLY

DB-2B

NMS REQ.

Local MI Bus

NE REPLY

Port
B

DM2+

Commtel Networks Proprietary

ST REQ.

DF2-8

TMS ADAPTOR : SERVICE MENUS

164

Commtel Networks Proprietary

TMS ADAPTOR : SERVICE MENUS

165

Commtel Networks Proprietary

TMS ADAPTOR : SERVICE MENUS

166

Commtel Networks Proprietary

TMS ADAPTOR : SERVICE MENUS

167

Commtel Networks Proprietary

TROUBLE SHOOTING OF TMS ADAPTOR

Power Supply Fault


Step 1:
- Check the incoming voltage level and the unit operating voltages (TOP,7,9,u,1..). Check for abnormality in
measurement.

Step 2:

If the above measures do not solve the problem. Remove the unit and re-inset back into designated slot

Step 3:

If the problem still persists, then there might be possibility of power supply section failure.
Memory Fault
This alarm is due to failure of memory of TMS adaptor. This Orange LED will glow.

Step 1:

Check that by re-inserting the unit whether alarm goes off, otherwise send the unit for repair.
Fault Database Full

The fault database contains at least 277 faults and 829 faults at the most. The minimum size 277 is applicable if the NEs

contains several FEs and each FE gives one fault. Currently only the Supervisory Substation (TC 21705) & Flexihopper
contains more than one FE. Therefore, the database size is normally 829. If the fault database becomes full, the TA
issues the alarm database full and the yellow LED is lit. After this the faults of the subnetwork equipment will not be
stored into the fault database of the TMS Adaptor before earlier faults are removed to create space for new faults
Step 1:

Reset the TMS Adaptor by the Port type menu function (e.g. for Port A 6,2,1,1 Port type TMC or 6,2,1,2 Port type
ST)

168

Commtel Networks Proprietary

TROUBLE SHOOTING OF TMS ADAPTOR

I am not able to access any NE connected to TMS adaptor

It is assumed that you have direct access to TMS adaptor and the installation is existing meaning no wiring problem in the
TMN network. Also there is no alarm in TMS adaptor such as Database Full and you are able to access the TMS adaptor
directly.
Step 1:
-

Check that Green LED of TMS Adaptor is flashing (Generally Port A connected NMS, flashes Green LED on activity).

Step 2:
-

Connect ST to Port B. Check the speeds & Port Type of Port A and B for correctness as per design value. (Generally
Port A is TMC type @9600 baud and Port B is Service Terminal type @ 4800 baud)

Step 3:
-

Check by isolating the Q1 DCC path from East side & then West side.

Step 4:
-

Check that NE address is within TMS Adaptors own address + NE count range.

Step 5:
-

Re-insert the TMS adaptor.

169

Commtel Networks Proprietary

Many Thanks
Indeed !!!
www.commtelnetworks.com

170

Commtel Networks Proprietary

Vous aimerez peut-être aussi