Vous êtes sur la page 1sur 74

Caledonian

Caledonian

High Temperature Cables


www.caledonian-cabes.co.uk
www.addison-cabes.com

Addison

Company Profile
Caledonian. established in 1978.offers one of the most complete lines of fiber and
copper cabling system solutions with over hundreds of different cabling system products.
Our superior products provide leading edge within every cable series and for every
application.
Among the national and international standards with which our cables could comply
are: BS - British Standard; LPCB Fire Performance Standard. ISO Standard etc.
Caledonian Cables offers a comprehensive stock of cables and cabling products through
its nationwide network of resellers and distributors. Caledonian Cables has continually
expanded its global presence in Europe and Asia.
Caledonian & Addison. produces a wide range of cables for communication. power
and electronics in its primary plants in UK. Italy and Spain. To stay in front. we continually
keep expanding our manufacturing capabilities in more low cost region such as Romania.
Taiwan. Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible.
scalable global system that delivers superior operational performance and optimal results
for our customers.
Our extensive global network of manufacturing facilities gives us significant scale and
the flexibility to fulfill our customer requirements. This global presence provides design
and consultancy solutions that are combined with core cable manufacturing. logistic
services. and vertically integrated with our E commerce technologies. to optimize customer
operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality. excellent
service level. competitive pricing and a unique and innovative spirit. With our latest
technologies. we are both inspired and well-positioned to meet the changing needs of
our customers. We have the resources to diversify and to enhance our product lines and
services. We understand the need for change and with our accurate planning. we are
ready for the future and the promise of new marketing opportunities. Our tradition of growth
through excellence is assured.
Our Design Centers work closely with customers to constantly improve its standard
range of products and technologies and to develop customized. country and industryspecific solutions. Caledonian & Addison has established an extensive network of design.
manufacturing. and logistics facilities in the worlds major markets to serve the growing
outsourcing needs of both multinational and regional customers.

Our Certificate

Caledonian

High Temperature Cables


www.caledonian-cabes.co.uk

Table of Content
Silicone cable
SIF - Silicone Single Core Stranded Cable.................................5
SIF / GL - Silicone Single Core with Glass fibre braiding cable............................7
SIHF - Silicone Control Cable.................................9
SiHF-GLP- Silicone Multi-Core Overall Stainless Steel Braid cable.....................................13
SiHF-C-Si - Silicone Multi-Core Shielded Double Jacket Cable......................................17
SID - Silicone Single Core Solid Conductor Cable.................................20
SID/GL - Silicone Single Core Glass fiber braid Solid Conductor cable...............................22

High Temperature Thermocouple Cable


FEP Insulated Thermocouple Wire and Extension Wire...............................24
TFE Insulated Thermocouple Wire and Extension Wire............................29
PFA Insulated Thermocouple Wire and Extension Wire ..................................35
Fiberglass Insulated Thermocouple Wire and Extension Wire...............................41
Flexible Thermocouple Wire(1024C)..........................................................47
PVC Single Pair Thermocouple Wire (105C)...............................52
PVC Multi Pair Thermocouple Wire (105C) .......................................55

High Temperature PTFE Cable.....................................................................58


P-Temp-500.............................................................................................................62
High Temperature Special Cable

PVC Flatform Cable...............................................64


Neoprene Flatform Cable.................................................66
TML Cable - Type A for Process Water, Type B Drinking Water.................................68
TML Cable Flat - Type A for Process Water, Type B Drinking Water.............................71
Siliconresinhigh temperaturewire................................73

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

SIF - Silicone Single Core Stranded Cable

Product application:
Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone
insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills,
coking plants, foundries etc. Insulation consists of silicone rubber. It is resistant to vegetable and
animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol,
alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an
insulation silicone dioxide layer will remain on the conductor to render it short circuit proof.

Product characteristic:
Construction:
Fine tinned copper strands
Strands to VDE-0295 Class-5, IEC 60228 Cl-5
Silicone core insulation
Cores to VDE-0293
Technical:
Working voltage: 300/500 volts
Test voltage: 2000 volts
Bending Radius: 15 x
Temp range: -50 C to +180 C
Short time temp up to +220 C
Flame retardant: IEC 60332.1
Insulation resistance: 20 M x km
Properties:
Advantages
High ignition or flash point

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

Resistant to
High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted
acids, lye and salt dissolution, oxidation substances, tropical influences and weather, lake water,
oxygen
Halogen-free
According to DIN VDE 0482 part 267/ EN 50267-2-1/ IEC 60754-1 (equivalent DIN VDE 0472 part
815)
Behavior in fire
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C.

Product specification:
AWG

No. of
Cores

24
20
18
17
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300kcmil
350 kcmil

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Conductor cross
section
mm2
0.25
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

Nominal OD
mm

Copper weight
kg/km

Gross Weight
kg/km

1.9
2.1
2.4
2.5
2.8
3.4
4.2
5.2
7.1
8.4
10.3
11.6
13.9
16.0
18.4
20.0
23.0
24.9

2.4
4.8
7.2
9.6
14.4
24
38
58
96
154
240
336
480
672
912
1152
1440.0
1776.0

5.5
8.6
11.8
13.5
18.5
30
47.3
71.1
119.4
187.7
289.6
398.3
559.7
765.8
1031.5
1284.6
1563.4
1858.2

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

SIF / GL - Silicone Single Core with Glass


fibre braiding cable

Product application:
Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone
insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills,
coking plants, foundries etc. Insulation consists of silicone rubber. It is resistant to vegetable and
animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol,
alkaline solutions, etc.The insulation is resistant to oxygen and ozone. Should the cable burn, an
insulation silicone dioxide layer will remain on the conductor to render it short circuit proof.Additional
mechanical protection due to the glass fibre braid.

Product characteristic:
Construction:
Fine strands of tinned copper wire
Stranding acc. to VDE 0295 class 5
Core insulation made of silicone rubber
Glass fibre braiding
Bending radius: 15x cable
Technical:
Special silicone single conductor cable with higher heat-resistance range adapted to DIN VDE
0250 part 1 and part 502
Temperature range :-60C to +180C
Short time temp up to 220C
Temperature limit at the conductor in operation +180C

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

Nominal voltage:300/500 V
Test voltage :2000 V
Minimum bending radius: 15x cable
6
Radiation resistance : up to 20x10 cJ/kg (up to 20 Mrad)

Properties:
High ignition or flash point
Resistant to high molecular oils, fats from vegetables and animals, alcohols, plasticizers and
clophenes, diluted acids, lye and salt dissolution, oxidation substances, tropical influences and
weather, lake water, oxygen
Halogen-free according to DIN VDE 0482 part 267/ EN 50267-2-1/ IEC 60754-1 (equivalent DIN
VDE 0472 part 815)
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C

Product specification:
AWG

No. of
Cores

24
20
18
17
16
14
12
10
8
6
4
2
1

1
1
1
1
1
1
1
1
1
1
1
1
1

Conductor
Cross Section
mm
0.25
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50

Nominal OD
mm

Copper weight
kg / km

2.4
2.6
2.9
3
3.3
3.9
4.7
5.7
7.5
8.9
10.8
12.1
14.4

2.4
4.8
7.2
9.6
14.4
24
38
58
96
154
240
336
480

Gross
Weight
kg / km
7.9
12.6
16
18.4
23.7
35.6
53.3
77.4
129.2
198.4
303
413.2
577.8

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

SIHF - Silicone Control Cable

Product application:
Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone
insulated single cores are commonly used in the metallurgical industry, steel works, hot rolling mills,
coking plants, foundries etc.The insulation consists of silicone rubber. It is resistant to vegetable and
animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol,
alkaline solutions etc. The insulation is resistant to oxygen and ozone. Should the cable burn, a silicone
dioxide layer will remain on the conductor to render it short circuit proof.

Product characteristic:
Construction:
Tinned copper conductors to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
Silicone conductor insulation
Conductor identification to DIN VDE 0293-308 color coded or black conductors with continuous
white numbers
For 2-conductors brown, blue
Conductors stranded in layers with optimal lay-length
Green-yellow earth-conductor (3 conductors and above)
Outer jacket of silicone
Technical:
Special silicone multi conductor cable with higher heat-resistance range adapted to DIN VDE 0250
part 1 and part 816
Working voltage: 300/500 volts
Test voltage: 2000 volts
Bending Radius: flexing 7.5 x cable , fixed installation 4 x cable
Temp range: -60 C to +180 C
Short time temp up to +220 C

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

Flame retardant: IEC 60332.1


Insulation resistance: min. 200 M x km
6
Radiation resistance: up to 20x10 cJ/kg (up to 20 Mrad)

Properties:
Hardly changes of dielectric strength and the insulation resistance also at high temperatures, high
ignition or flash point, in case of fire, forms an insulating layer of SiO2
Resistant to high molecular oils, fats from vegetables and animals, alcohols, plasticizers and
clophenes, diluted acids, lye and salt dissolution, oxidation substances, tropical influences and
weather, lake water, oxygen and UV
Halogen-free according to DIN VDE 0482 part 267/ EN 50267-2-2/ IEC 60754-2 (equivalent DIN
VDE 0472 part 813)
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C.

Product specification:
AWG

No. of
Cores

20
20
20
20
20
20
20
20
20
20
20
20
18

2
3
4
5
6
7
8
10
12
16
18
25
2

10

Conductor
cross section
mm2
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75

Nominal OD
mm

Copper weight
kg/km

5.5
5.8
6.2
6.8
7.4
7.4
8.6
9.5
9.8
11
11.5
13.7
6.4

9.6
14.5
19.3
24
28.9
33.7
38.4
48.1
57.6
76.7
86.5
120
14.4

Gross
Weight
kg/km
42
44
58
62
79
85
99
124
141
186
211
271
53

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

AWG

No. of
Cores

18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16

3
4
5
6
7
8
10
12
16
18
25
2
3
4
5
6
7
8
10
12
16
18
25
2
3
4
5
6
7
8
10
12
14
16
18
20
24

Conductor
cross section
mm2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1
1
1
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

Nominal OD
mm

Copper weight
kg/km

6.8
7.8
8.5
9.2
9.2
9.7
10.9
11.1
12.6
13.3
15.6
6.6
7.4
8
8.8
9.5
9.5
10.4
11.3
11.5
13.1
13.8
16.2
7.6
8
8.8
9.6
10.4
10.4
11.6
13.6
14.6
15.4
16.7
17.6
18.2
20

21.6
29
36
43
50
57.7
72.1
86.5
115.2
129.7
180
19
29
38
48
58
67
76.7
96.1
115.2
153.5
172.9
240
29
43
58
72
86
101
114
116
173
202
231
260
288
346

Gross
Weight
kg/km
63
83
101
115
124
138
156
185
218
260
370
59
77
94
115
134
144
175
216
231
302
340
431
81
98
122
147
173
187
213
263
314
379
445
506
566
722

11

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

AWG

No. of
Cores

14
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
10
8
8
8
8
8
6
6
6
6
6
4
4
4
2
2
2

2
3
4
5
6
7
8
10
12
16
18
25
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
2
3
4
2
3
4

12

Conductor
cross section
mm2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
6
6
6
6
6
10
10
10
10
10
16
16
16
16
16
25
25
25
35
35
35

Nominal OD
mm

Copper weight
kg/km

9.2
9.7
10.6
11.6
12.9
13
14.9
16.5
17.8
19.1
20
24.5
10.8
11.4
13.1
14.4
16.2
13.4
14.2
16.2
17.7
19.2
17.6
18.7
20.4
22.5
24.4
20.4
22
24.3
26.7
27.6
24.6
26.2
31.8
28.2
29.9
32.8

48
72
96
120
144
168
192.2
240.1
288
384
432
600
77
115
154
192
269
115
173
230
288
403
192
288
384
480
672.2
308
462
616
770
1075.3
480
720
960
672
1008
1344

Gross
Weight
kg/km
134
152
188
228
304
320
373
450
502
659
761
1007
180
224
295
359
479
274
338
441
535
685
400
620
707
900
1151
400
500
714
850
1682
700
1100
1500
1100
1500
2100

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

SiHF-GLP- Silicone Multi-Core Overall


Stainless Steel Braid

Product application:
SiHF-GLPis a special 180 Degree C. silicone multi-core cable with an overall steel braid for use in
high and low temperature areas or whenever the insulation is subject to extreme temperature changes.
These cables are mainly found in steel producing industry and aviation industry as well as in ship
building, cement, glass and ceramic factories. SIHF-GLP cables are low-smoke and halogen-free
especially suited for use in power stations. The silicone jacket provides added heat, chemical, oil and
acidic resistance. The external galvanized steel braid ensures excellent mechanical protection and
disturbance-free transmissions of signals and impulses. Not permitted for outdoor use.

Product characteristic:
Construction:
Tinned copper conductors to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
Silicone conductor insulation
Conductor identification to DIN VDE 0293-308 color coded or black conductors with continuous
white numbers
For 2-conductors brown, blue
Conductors stranded in layers with optimal lay-length
Green-yellow earth-conductor (3 conductors and above)
Outer jacket of silicone
Jacket color preferably red brown
Glass fibre tape over the jacket
Galvanized steel wire outer braiding

13

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

Technical:
Special silicone multi conductor cable with higher heat-resistance range adapted to DIN VDE 0250
part 1 and part 816
Temperature range: -60C to +180C
Short time temp up to +220 C
Temperature limit at the conductor
in operation +180C
Nominal voltage : 300/500 V
Test voltage :2000 V
Insulation resistance: min.200 M x km
Minimum bending radius: flexing 10 x cable
fixed installation 5 x cable
6
Radiation resistance :up to 20x10 cJ/kg (up to 20 Mrad)

Properties
Advantages
Hardly changes of dielectric strength and the insulation resistance also at high temperatures, high
ignition or flash point, in case of fire, forms an insulating layer of SiO2
Resistant to
High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted
acids, lye and salt dissolution, oxidation substances, tropical influences and weather, lake water,
oxygen
Halogen-free
According to DIN VDE 0482 part 267/ EN 50267-2-2/ IEC 60754-2 (equivalent DIN VDE 0472 part
813)
Behavior in fire
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C

14

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Product specification:
AWG

No. of
Cores

18
18
18
18
18
18
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14

2
3
4
5
6
7
2
3
4
5
6
7
2
3
4
5
6
7
8
10
12
14
16
18
20
24
2
3
4
5
6
7
12

Conductor
cross section
mm2
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Nominal OD
mm

Copper weight
kg/km

7.2
7.6
8.1
9.2
9.9
9.9
7.6
8
8.8
9.7
10.4
10.4
8.3
8.7
9.6
10.4
11.4
11.4
12.7
14
14.5
15.6
17
17.8
18.3
20.4
9.7
10.2
11.5
12.7
13.7
13.7
17.6

14.4
21.6
29
36
43
50
19
29
38
48
58
67
29
43
58
72
86
101
116
144
173
202
231
260
288
346
48
72
96
120
144
168
288

Gross
Weight
kg/km
88
99
121
147
169
178
98
119
139
167
185
194
126
143
170
198
245
256
315
370
408
471
541
599
630
760
165
238
268
315
370
385
608

15

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

AWG

No. of
Cores

12
12
12
12
12
12
10
10
10
10
10
10
8
8
8
8
6
6
6
6
4
4
4
2
2
2
1
1
1
2/0
2/0
2/0
3/0
3/0
3/0
4/0
4/0

2
3
4
5
6
7
2
3
4
5
6
7
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4

16

Conductor
cross section
mm2
4
4
4
4
4
4
6
6
6
6
6
6
10
10
10
10
16
16
16
16
25
25
25
35
35
35
50
50
50
70
70
70
90
90
90
120
120

Nominal OD
mm

Copper weight
kg/km

11.5
12.2
13.4
15.1
16.4
16.4
12.9
13.7
14.8
16.8
18.2
18.2
17.3
18.4
20.6
22.5
20.2
21.5
23.4
26.2
23.8
26
28.3
27.2
29
32.3
31.4
33.5
37.2
35.3
38.3
42.5
41.4
44.8
49.8
48.8
54.1

77
115
154
192
230
269
115
173
230
288
346
403
192
288
384
480
308
462
616
770
480
720
960
672
1008
1344
960
1440
1920
1344
2016
2688
1824
2736
3648
3465
4620

Gross
Weight
kg/km
255
299
365
455
525
556
326
401
485
602
701
736
543
652
825
987
748
909
1183
1393
1046
1347
1678
1378
1846
2240
1869
2384
2702
2482
3314
4074
3380
4299
5339
5277
6571

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

SiHF-C-Si -Silicone Shielded Double


Jacket Multi-Core Cable

Product application:
SiHF-C-Si is a special 180 Degree C. silicone multi-core cable for use in high and low temperature
areas or whenever the insulation is subject to extreme temperature changes. These cables are mainly
found in steel producing industry and aviation industry as well as in ship building, cement, glass and
ceramic factories. SIHF-C-Si cables are low-smoke and halogen-free especially suited for use in power
stations. The silicone jacket provides added heat, chemical, oil and acidic resistance while the internal
tinned copper braid shield protects against electromagnetic interference offering disturbance free
signals and impulses. Not permitted for outdoor use.

Product characteristic:
Construction:
Tinned copper conductor according to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
Conductor insulation of silicone
Conductor identification according to DIN VDE 0293-308, single color, or black conductors with
sequential numbering imprinted in white, for 2 conductors brown, blue
Conductors stranded in layers with optimal lay-length
Green-yellow grounding (3 conductors)
Inner jacket of silicone
Braid of tinned Cu wires, coverage approx. 85%
Silicone-rubber-insulated common outer jacket
Jacket preferentially red brown color
Technical:
Special silicone-insulated cable with higher heat-resistance adapted to DIN VDE 0250 part 1 and
part 816

17

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

Temperature range: -60C to +180C


Short time temp up to +220 C
Temperature limit at the conductor in operation +180C
Nominal voltage: 300/500 V
Test voltage: 2000 V
Insulation resistance :min. 200 M x km
Minimum bending radius: flexing 10 x cable

fixed installation 5 x cable

Coupling resistance :max. 250/km


6
Radiation resistance : up to 20x10 cJ/kg (up to 20 Mrad)

Properties:
Resistant to high molecular oils, fats from vegetables and animals, alcohols, plasticizers and
clophenes, diluted acids, lye and salt dissolution, oxidation substances, tropical influences and
weather, lake water, oxygen and UV
Halogen-free according to DIN VDE 0482 part 267/ EN 50267-2-2/ IEC 60754-2 (equivalent DIN
VDE 0472 part 813)
No propagation of fire
Testing according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C.

Product specification:
AWG

No. of
Cores

20
20
20
20
20
20
20
20
20
20

2
3
4
5
7
10
12
16
18
25

18

Conductor
cross section
mm2
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25

Nominal OD
mm
8.7
8.9
9.4
10
10.5
13.1
13.4
14.6
15.1
19.4

Copper
weight
kg/km
55.5
60.8
66.5
81.6
92.2
124
134.4
170.2
181
230.1

Gross
Weight
kg/km
101
118
131
153
173
242
263
326
351
348

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

AWG

No. of
Cores

18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
12
12
12
10
10
8
6
4

2
3
4
5
7
10
12
16
18
25
2
3
4
5
7
10
12
16
18
25
2
3
4
5
7
10
12
16
18
25
2
3
4
5
7
2
4
5
4
5
4
4
4

Conductor
cross section
mm2
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1
1
1
1
1
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
4
4
4
6
6
10
16
25

Nominal OD
mm
9.2
9.5
10.1
10.8
11.6
14.4
14.7
16.5
17.3
22.1
9.5
9.7
10.4
11.3
12
14.9
15.2
17
17.8
23
10.7
11.2
11.8
13.3
14.3
17.7
18
20.1
20.9
24.1
12.1
12.9
14.2
15.3
16.9
14.6
17.1
19.4
18.8
21.2
25.7
28.4
35

Copper
weight
kg/km
61.4
69.1
86.7
95.2
113.3
165.2
180.3
212.2
282.1
297.4
66.7
86.2
96.8
108.3
141.2
190
209.8
251.8
297.4
329
87.7
103.5
131.7
148.5
193.4
268.5
298.4
362.3
394
488.2
122.3
147.7
188.6
214.9
265.7
159.2
294
374
449
563
759
1180
1810

Gross
Weight
kg/km
124
136
159
180
212
306
333
418
453
468
132
153
173
202
243
238
371
468
526
559
172
198
235
281
345
482
531
662
720
791
230
275
340
394
488
444
520
653
781
982
1294
1988
2995

19

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

SID - Silicone Single Core Solid Conductor


Cable

Product application:
SID cables are suitable where PVC insulated cables become brittle due to high temperature variations.
Silicone insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling
mills, coking plants, foundries etc. Insulation consists of silicone rubber. It is resistant to vegetable and
animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol,
alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an
insulation silicone dioxide layer will remain on the conductor to render it short circuit proof. Suitable for
fixed installation.

Product characteristic:
Construction:
Solid tinned copper single wire
Solid to VDE-0295 Class-1, IEC 60228 Cl-1
Silicone core insulation
High ignition and flash point
Technical:
Working voltage: 300/500 volts
Test voltage: 2000 volts
Bending Radius: 5 x cable
Temp range: -60 C to +180 C
Short time temp up to +220 C
Flame retardant: IEC 60332.1
Insulation resistance: 20 M x km

20

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Properties:
Advantages
High ignition or flash point
Resistant to
High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted
acids, lye and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen
Halogen-free
According to DIN VDE 0482 part 267/ EN 50267-2-1/ IEC 60754-1 (equivalent DIN VDE 0472 part
815)
Behavior in fire
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C

Product specification:
AWG

No. of Cores

20
18
17
16
14
12
10

1
1
1
1
1
1
1
1
1

Conductor
Cross Section
mm
0.2
0.28
0.5
0.75
1
1.5
2.5
4
6

Nominal OD
mm
1.7
1.8
2
2.2
2.3
2.6
3.2
3.9
4.4

Copper
weight
kg / km
1.9
2.7
4.8
7.2
9.6
14.4
24
38
58

Gross
Weight
kg / km
4.2
5.1
7.7
10.4
12.8
18
28.9
45.4
64.5

21

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk

SID/GL - Silicone Single Core Glass fiber


braid Solid Conductor Cable

Product application:
SID/GL cables are suitable where PVC insulated cables become brittle due to high temperature
variations. Silicone insulated single cores are preferably used in the metallurgical industry, steel works,
hot rolling mills, coking plants, foundries etc. Insulation consists of silicone rubber. It is resistant to
vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed
to alcohol, alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable
burn, an insulation silicone dioxide layer will remain on the conductor to render it short circuit proof.
Suitable for fixed installation.

Product characteristic:
Construction:
Solid tinned copper single wire
Solid to VDE-0295 Class-1, IEC 60228 Cl-1
Silicone core insulation
High ignition and flash point
Glass fiber braiding
Technical:
Working voltage: 300/500 volts
Test voltage: 2000 volts
Only for fixed applications
Temp range: -60 C to +180 C
Short time temp up to +220 C
Flame retardant: IEC 60332.1
Insulation resistance: 20 M x km

22

Caledonian High Temperature Cables

High Temperature Silicone Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Properties:
Advantages
High ignition or flash point
Resistant to
High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted
acids, lye and salt dissolution, oxidation substances, tropical influences and weather, lake water,
oxygen
Halogen-free
According to DIN VDE 0482 part 267/ EN 50267-2-1/ IEC 60754-1 (equivalent DIN VDE 0472 part
815)
Behavior in fire
No flame propagation
Test according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts.
Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures
exceeding 90C.

Product specification:
AWG

No. of Cores

20
18
17
16
14
12
10

1
1
1
1
1
1
1

Conductor
Cross Section
mm
0.5
0.75
1
1.5
2.5
4
6

Nominal OD
mm

Copper weight
kg / km

2.5
2.7
2.8
3.1
3.7
4.4
4.9

4.8
7.2
9.6
14.4
24
36
58

Gross
Weight
kg / km
10
15
19
28
40
55
80

23

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

FEP Insulated Thermocouple Wire and


Extension Wire

Product application:
FEP Insulated Thermocouple Wire may be used for general use extension wire for thermocouples

Product characteristic:
Construction:
Solid or stranded thermocouple wire
Flame retardant extruded fluoropolymer FEP insulation
Parallel conductors
Flame retardant extruded fluoropolymer FEP jacket
Technical:
Maximum temp up to +200 C, continuous 250C
Minimum Bend Radius: insulation 3 x cable
overall 5 x cable
Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS

24

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Properties:
Excellent abrasion, chemical and moisture resistance
Service temperature of 200 C
Low friction factor when pulled
Flame retardant; non-propagating in fire conditions

Product specification:
Type K Thermocouple Wire
Chromel/Alumel Thermocouple Wire Type K
AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Type K Thermocouple Wire - Extension Grade


Chromel/Alumel Extension Grade Thermocouple Wire Type K

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

25

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Type J Thermocouple Wire


Iron/Constantan Thermocouple Wire Type J

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Type J Thermocouple Wire - Extension Grade


Iron/Constantan Extension Grade Thermocouple Wire Type J

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Type T Thermocouple Wire


Copper/Constantan Thermocouple Wire Type T

AWG
30
24
24
20
20
16

26

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Type T Thermocouple Wire - Extension Grade


Copper/Constantan Extension Grade Thermocouple Wire Type T

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Type E Thermocouple Wire


Chromel/Constantan Thermocouple Wire Type E

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

Type E Thermocouple Wire - Extension Grade


Chromel/Constantan Extension Grade Thermocouple Wire Type E

AWG
30
24
24
20
20
16

Conductor Cross
Section
mm
0.05
0.2
0.2
0.5
0.5
1.5

Nominal Thickness mm
Insulation
0.1
0.2
0.2
0.2
0.2
0.2

Jacket
0.15
0.25
0.25
0.25
0.25
0.25

O.D.
0.76/1.21
1.42/2.33
0.15/2.54
1.73/2.95
1.88/3.25
2.21/3.91

Gross
Weight
kg/km
3
9
10
18
19
36

27

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Type N Thermocouple Wire


Nicrosil/Nisil Thermocouple Wire Type N

Insulation

Jacket

O.D.

30

Conductor Cross
Section
mm
0.05

0.1

0.15

0.76/1.21

Gross
Weight
kg/km
3

24

0.2

0.2

0.25

1.42/2.33

24

0.2

0.2

0.25

0.15/2.54

10

20

0.5

0.2

0.25

1.73/2.95

18

20

0.5

0.2

0.25

1.88/3.25

19

16

1.5

0.2

0.25

2.21/3.91

36

AWG

Nominal Thickness mm

Type N Thermocouple Wire - Extension Grade


Nicrosil/Nisil Extension Grade Thermocouple Wire Type N

Insulation

Jacket

O.D.

30

Conductor Cross
Section
mm
0.05

0.1

0.15

0.76/1.21

Gross
Weight
kg/km
3

24

0.2

0.2

0.25

1.42/2.33

24

0.2

0.2

0.25

0.15/2.54

10

20

0.5

0.2

0.25

1.73/2.95

18

20

0.5

0.2

0.25

1.88/3.25

19

16

1.5

0.2

0.25

2.21/3.91

36

AWG

28

Nominal Thickness mm

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

TFE Insulated Thermocouple Wire and


Extension Wire

Product application:
TFE Thermocouple Wire may be used for aircraft and petroleum processing

Product characteristic:
Construction:
Solid or stranded thermocouple wire
Fused TFE tape insulation
Parallel conductors
Flame retardant extruded fluoropolymer TFE jacket
Technical:
Continuous temperature rating:260C
Minimum Bend Radius: insulation 3 x cable overall 5 x cable
Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS
Properties:
Excellent abrasion, chemical and moisture resistance.
Service temperature of 260C

29

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Low friction factor when pulled


Flame retardant; non-propagating in fire conditions

Product specification:
TFE Insulated Type J Thermocouple Wire
Iron/Constantan TFE Thermocouple Wire 260C

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

TFE Insulated Extension Grade Type JX Thermocouple Wire


Iron/Constantan TFE Thermocouple Wire 260C - Extension Grade

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

30

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

TFE Insulated Type K Thermocouple Wire


Chromel/Alumel TFE Thermocouple Wire 260C

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

TFE Insulated Extension Grade Type KX Thermocouple Wire


Chromel/Alumel TFE Thermocouple Wire 260C - Extension Grade

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

31

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

TFE Insulated Type T Thermocouple Wire


Copper/Constantan TFE Thermocouple Wire 260C

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

TFE Insulated Extension Grade Type TX Thermocouple Wire


Copper/Constantan TFE Thermocouple Wire 260C - Extension Grade

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

32

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

TFE Insulated Type E Thermocouple Wire


Chromel/Constantan TFE Thermocouple Wire 260C

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

TFE Insulated Extension Grade Type EX Thermocouple Wire


Chromel/Constantan TFE Thermocouple Wire 260C - Extension Grade

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

33

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

TFE Insulated Type N Thermocouple Wire


Nicrosil/Nisil TFE Thermocouple Wire 260C

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

TFE Insulated Extension Grade Type NX Thermocouple Wire


Nicrosil/Nisil TFE Thermocouple Wire 260C - Extension Grade

AWG
26
24
24S*(7/32)
20
20S*(7/28)
18
18S*(7/26)
16
16S*(7/24)

34

Nominal
Conductor
Diameter
mm
0.406
0.508
0.61
0.813
0.965
1.02
1.22
1.29
1.52

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.152
0.152
0.152
0.152
0.152
0.152
0.152
0.254
0.254

0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203
0.203

1.12*1.83
1.19*1.95
1.24*2.13
1.55*2.69
1.63*2.84
1.73*3.05
1.93*3.45
2.21*4.01
2.44*4.47

6
7.5
8.9
16.4
17.9
23.8
26.8
37.3
40.2

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

PFA Insulated Thermocouple Wire and


Extension Wire

Product application:
PFA Thermocouple Wire may be used for general use extension wire.

Product characteristic:
Construction:
Solid or stranded tinned copper thermocouple wire
Flame retardant extruded fluoropolymer PFA insulation
Parallel conductors
Flame retardant extruded fluoropolymer PFA jacket
Technical:
Continuous temperature rating:260C
Minimum Bend Radius: insulation 3 x cable

overall 5 x cable

Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS
Properties:
Excellent abrasion, oil, chemical and moisture resistance.
Service temperature of 260C
Low friction factor when pulled.

35

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Product specification:
PFA-Insulated Type J Thermocouple Wire
Iron/Constantan PFA Thermocouple Wire 260C

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

PFA-Insulated Type J Thermocouple Wire - Extension Grade


Iron/Constantan PFA Thermocouple Wire 260C - Extension Grade

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

36

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

PFA-Insulated Type K Thermocouple Wire


Chromel/Alumel PFA Thermocouple Wire260C

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

PFA-Insulated Type K Thermocouple Wire - Extension Grade


Chromel/Alumel PFA Thermocouple Wire 260C - Extension Grade

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

37

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

PFA-Insulated Type T Thermocouple Wire


Copper/Constantan PFA Thermocouple Wire 260C

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

PFA-Insulated Type T Thermocouple Wire - Extension Grade


Copper/Constantan PFA Thermocouple Wire 260C - Extension Grade

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

38

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

PFA-Insulated Type E Thermocouple Wire


Chromel/Constantan PFA Thermocouple Wire 260C

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

PFA-Insulated Type E Thermocouple Wire - Extension Grade


Chromel/Constantan PFA Thermocouple Wire 260C - Extension Grade

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

39

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

PFA-Insulated Type N Thermocouple Wire


Nicrosil/Nisil PFA Thermocouple Wire 260C

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

PFA-Insulated Type N Thermocouple Wire - Extension Grade


Nicrosil/Nisil PFA Thermocouple Wire 260C - Extension Grade

AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

40

Nominal
Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.6 x 4.8
2.2 x 3.9
2.4 x 4.3
1.9 x 3.4
1.7 x 2.9
1.8 x 3.1
1.5 x 2.6
1.4 x 2.3
1.6 x 2.7
1.3 x 2.1
1.2 x 2.0
1.2 x 1.8

51
33
36
22
16
18
11
8.5
9.2
6.5
5.5
4.5

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Fiberglass Insulated Thermocouple Wire


and Extension Wire

Product application:
Fiberglass Thermocouple Wire is ideal for general applications requiring moderate abrasion, moisture
resistance, and wide temperature capabilities

Product characteristic:
Construction:
Solid or stranded tinned copper thermocouple wire
Braided fiberglass insulation
Parallel conductors
Braided fiberglass jacket
Technical:
Continuous temperature rating: 400C
Minimum Bend Radius: insulation 3 x cable

overall 5 x cable

Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS
Properties:
Good thermal durability and tensile strength
Service temperature up to 400C

41

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Good dielectric and electrical characteristics


Braided fiberglass insulation for abrasion resistance
Braided fiberglass jacket for additional flexibility and abrasion resistance

Product specification:
Fiberglass Type K Thermocouple Wire
Chromel/Alumel Fiberglass Thermocouple Wire Type K
AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

Nominal Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

Gross
Weight
kg/km
43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Fiberglass Type K Thermocouple Wire Extension Grade


Chromel/Alumel Fiberglass Thermocouple Wire Type K
AWG
14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

42

Nominal Conductor
Diameter
mm
1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

Nominal Thickness mm
Insulation

Jacket

O.D.

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

Gross
Weight
kg/km
43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Fiberglass Type J Thermocouple Wire


Iron/Constantan Fiberglass Thermocouple Wire Type J

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

Fiberglass Type J Thermocouple Wire Extension Grade


Iron/Constantan Fiberglass Thermocouple Wire Type J

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

43

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Fiberglass Type T Thermocouple Wire


Copper/Constantan Fiberglass Thermocouple Wire Type T

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

Fiberglass Type T Thermocouple Wire Extension Grade


Copper/Constantan Fiberglass Thermocouple Wire Type T

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

44

Nominal Thickness mm

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Fiberglass Type E Thermocouple Wire


Chromel/Constantan Fiberglass Thermocouple Wire Type E

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

Fiberglass Type E Thermocouple Wire Extension Grade


Chromel/Constantan Fiberglass Thermocouple Wire Type E

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

45

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Fiberglass Type N Thermocouple Wire


Nicrosil/Nisil Fiberglass Thermocouple Wire Type N

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

Nominal Thickness mm

Fiberglass Type N Thermocouple Wire Extension Grade


Nicrosil/Nisil Fiberglass Thermocouple Wire Type N

AWG

Nominal Conductor
Diameter
mm

Insulation

Jacket

O.D.

Gross
Weight
kg/km

14
16
16S*
18
20
20S*
22
24
24S*
26
28
30

1.63
1.29
1.47
1.02
0.81
0.97
0.64
0.51
0.61
0.41
0.32
0.25

0.18
0.18
0.18
0.18
0.15
0.15
0.15
0.15
0.15
0.11
0.11
0.11

0.25
0.25
0.25
0.25
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.15

2.5 x 4.6
2.2 x 3.8
2.4 x 4.3
1.8 x 3.2
1.4 x 2.5
1.5 x 2.7
1.2 x 2.2
1.0 x 1.7
1.2 x 2.1
0.9 x 1.5
0.8 x 1.4
0.8 x 1.2

43
30
33
19
11
12
8
4.8
5.1
3.3
2.5
1.9

46

Nominal Thickness mm

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Flexible Thermocouple Wire(1024C)

Product application:
These cables are designed for a range of applications which include: replacement for beaded
thermocouples, thermocouple for oven surveys, heat treating or forging, casting of steel or titanium,
thermocouple for coke ovens, soaking pits where more flexibility is required compared to mineral
insulated products. Designed for extreme temperature applications.

Product characteristic:
Construction:
Solid or stranded thermocouple wire
Fused TFE tape insulation
Parallel conductors
Flame retardant extruded fluoropolymer TFE jacket
Technical:
Continuous temperature rating:260C
Minimum Bend Radius: insulation 3 x cable

overall 5 x cable

Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS

47

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Properties:
Designed for extended high temperature service of (1024C) with intermittent use of (1432C)
Good flexibility.
Replaces beaded thermocouples.
Excellent thermocouple probe in various high temperature applications.

Product specification:
Flexible Type K Thermocouple Wire
Chromel/Alumel FlexibleThermocouple Wire Type K

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type K Thermocouple Wire Extension Grade


Chromel/Alumel Flexible Thermocouple Wire Type K

AWG
24
20
16
14

48

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Flexible Type J Thermocouple Wire


Iron/Constantan Flexible Thermocouple Wire Type J

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type J Thermocouple Wire Extension Grade


Iron/Constantan Flexible Thermocouple Wire Type J

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type T Thermocouple Wire


Copper/Constantan Flexible Thermocouple Wire Type T

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

49

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Flexible Type T Thermocouple Wire Extension Grade


Copper/Constantan Flexible Thermocouple Wire Type T

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type E Thermocouple Wire


Chromel/Constantan Flexible Thermocouple Wire Type E

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type E Thermocouple Wire Extension Grade


Chromel/Constantan Flexible Thermocouple Wire Type E

AWG
24
20
16
14

50

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Flexible Type N Thermocouple Wire


Nicrosil/Nisil Flexible Thermocouple Wire Type N

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

Flexible Type N Thermocouple Wire Extension Grade


Nicrosil/Nisil Flexible Thermocouple Wire Type N

AWG
24
20
16
14

Nominal
Conductor
Diameter
mm
12.954
20.574
32.766
41.402

Nominal Thickness mm
Insulation

Jacket

O.D.

Gross
Weight
kg/km

0.381
0.381
0.381
0.381

0.381
0.381
0.381
0.381

2.03/3.3
2.34/3.92
2.82/4.88
3.15/5.54

9
15
30
48

51

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

PVC Single Pair Thermocouple Wire (105C)

Product application:
PVC Single Pair Thermocouple Wire is rated for use in cable tray conduit or direct burial applications

Product characteristic:
Construction:
Solid or stranded thermocouple alloy
Extruded high temperature 105C PVC insulation
When twisted shielded pair construction (SF), 100% aluminum-polyester tape with drain.
Extruded PVC jacket
Technical:
Continuous temperature rating: 105C
Minimum Bend Radius: insulation 3 x cable

overall 5 x cable

Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS
Properties:
Good dielectric mechanical strength and flexibility
Service temperature up 105C
Good resistance to water, abrasion, oil and chemicals
Economical, general use

52

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Rated for use in cable tray conduit or direct burial applications

Product specification:
Solid Conductor, Parallel Pair

AWG

Strand

20
16
14
20
16
14

Solid
Solid
Solid
Solid
Solid
Solid

Insulation Thickness mm
Primary
0.254
0.381
0.432
0.254
0.381
0.432

Jacket
0.508
0.508
0.635
0.508
0.508
0.635

O.D.
mm

Gross Weight
kg/km

2.34/3.66
3.23/5.13
3.76/6.25
2.34/3.66
3.23/5.13
3.76/6.25

21
40
57
21
40
57

O.D.
mm

Gross Weight
kg/km

2.62/4.23
3.23/5.51
2.62/4.23
3.23/5.51

21
43
21
43

Stranded Conductor, Parallel Pair

AWG

Strand

20
16
20
16

7/28
7/24
7/28
7/24

Insulation Thickness mm
Primary
0.305
0.381
0.305
0.381

Jacket
0.508
0.508
0.508
0.508

Solid Conductor, Shielded Pair

AWG

Strand

20
16
20
16

Solid
Solid
Solid
Solid

Insulation Thickness mm
Primary
Jacket
0.254
0.508
0.381
0.584
0.254
0.508
0.381
0.584

O.D.
mm

Gross Weight
kg/km

3.912
5.385
3.912
5.385

21
40
21
40

53

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Stranded Conductor, Shielded Pair

AWG

Strand

20
16
20
16

7/28
7/24
7/28
7/24

Insulation Thickness mm
Primary

Jacket

O.D.
mm

Gross Weight
kg/km

0.305
0.406
0.305
0.406

0.508
0.584
0.508
0.584

4.47
5.69
4.47
5.69

24
43
24
43

Gross Weight
kg/km
24
43
24
43

Stranded with Filler

AWG

Strand

20
16
20
16

7/28
7/24
7/28
7/24

54

Insulation Thickness mm
Primary

Jacket

O.D.
mm

0.305
0.406
0.305
0.406

0.508
0.584
0.508
0.584

4.572
5.842
4.572
5.842

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

PVC Multi Pair Thermocouple Wire (105C)

Product application:
PVC Multi Pair Thermocouple Wire may be used in the transmission of telephone or other signals.

Product characteristic:
Construction:
20 gauge solid thermocouple alloy.
Extruded high temperature 105C PVC insulation.
Color coded twisted pairs, numbered sequentially for easy identification.
Matched pairs are twisted to reduce the amount of electromagnetic interference.
Flame retardant PVC jacket with ripcord.
On individually shielded pairs the shields are isolated from each other.
Technical:
Continuous temperature rating: 105C
Minimum Bend Radius: insulation 3 x cable

overall 5 x cable

Limits of Error: Conforms to ASTM E230, IEC 584, and ANSI MC 96.1
Color Code: Conforms to ANSI, IEC, JIS

55

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk

Properties:
Allows a multiple of sensors to be connected to associated instrumentation
Good resistance to weather, moisture, oils, alkalies, and mechanical abrasion
PVC offers high dielectric
Maximum noise rejection with overall shield
Transmission of telephone or other signal with communications wire in core
Non-propagating, flame retardant

Product specification:
Multi Pair Extension Cable With Overall Shield

AWG

Strand

Number of
Pairs

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid

4
6
8
12
16
20
24
36
50
8
6
50
4
36
24
20
16
12

56

Thickness of
Jacket
mm
1.016
1.27
1.27
1.27
1.27
1.524
1.524
1.524
1.778
1.27
1.27
1.778
1.016
1.524
1.524
1.524
1.27
1.27

O.D.
mm
9.042
10.82
11.76
13.665
15.748
16.358
18.44
20.777
24.282
11.76
10.82
24.282
9.042
20.777
18.44
16.358
15.748
13.665

Gross
Weight
kg/km
100
144
179
243
324
385
455
631
867
179
144
867
100
631
455
385
324
243

Caledonian High Temperature Cables

High Temperature Thermocouple Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Multi Pair Extension Cable With Individually Shielded Pairs

AWG

Strand

Number of
Pairs

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid
Solid

4
6
8
12
16
20
24
36
50
8
6
50
4
36
24
20
16
12

Thickness of
Jacket
mm
1.27
1.27
1.27
1.524
1.524
1.524
1.524
1.778
1.778
1.27
1.27
1.778
1.27
1.778
1.524
1.524
1.524
1.524

O.D.
mm
10.668
12.573
13.589
16.51
18.161
19.558
21.717
24.638
28.829
13.589
12.573
28.829
10.668
24.638
21.717
19.558
18.161
16.51

Gross
Weight
kg/km
135
186
231
339
430
513
598
863
1158
231
186
1158
135
863
598
513
430
339

57

Caledonian High Temperature Cables

High Temperature PTFE Cables


www.caledonian-cabes.co.uk

High Temperature PTFE Cable

Product application:
Equipment wire for high performance aerospace applications. PTFE wires are used in severe
environmental conditions.

Product characteristic:
Construction:
Stranded silver or nickel plated copper conductor
Polytetrafluoroethylene insulation
Sheath colour:Black, Blue, Brown, Red, White, Grey, Violet, Pink, Orange, Yellow, Green/Yellow to
BS 3G Z10
Technical:
Temperature Rating: -75C to +190C
Minimum Bending Radius: 6 x overall diameter
Voltage Working: Type A 300V Test 2500V
Type B 600V Test 3400V
Type C 1000V Test 5000V
Colour code confirms to BS 3G Z10
Properties:
Good resistance to oils, fuels and fluids
Heat resistance
Voltage ratings are conforming to American MIL, VDE, DIN, BS, or Lloyds standards

58

Caledonian High Temperature Cables

High Temperature PTFE Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Product specification:
AWG
30
28
28
26
26
24
24
24
22
22
22
20
20
20
18
18
16
14
12
10

Strand x
Diameter
mm
7/0.10
7/0.12
7/0.12
7/0.15
7/0.15
7/0.20
7/0.20
7/0.20
19/0.15
19/0.15
19/0.15
19/0.20
19/0.20
19/0.20
19/0.25
19/0.25
19/0.30
19/0.36
19/0.45
37/0.40

Conductor
Cross Section
mm
0.056
0.089
0.089
0.14
0.14
0.22
0.22
0.22
0.35
0.35
0.35
0.61
0.61
0.61
0.96
0.96
1.23
1.94
3.08
4.65

Voltage
Grade

O/D mm
min - max

A
A
B
A
B
A
B
C
A
B
C
A
B
C
B
C
C
C
C
C

0.50-0.65
0.56-0.71
0.76-0.96
0.65-0.80
0.85-1.05
0.80-0.95
1.00-1.20
1.26-1.52
0.95-1.10
1.15-1.35
1.41-1.67
1.20-1.35
1.40-1.60
1.66-1.92
1.65-1.85
1.91-2.17
2.16-2.46
2.34-2.74
2.91-3.31
3.46-3.86

Gross
Weight
kg/km
1.1
1.4
2.1
1.1
3.09
3.04
3.89
4.64
4.41
5.44
6.43
7.19
8.43
9.08
12.1
14.3
16.5
23.9
38.5
56.0

59

Caledonian High Temperature Cables

High Temperature P-Temp-500 Cable


www.caledonian-cabes.co.uk

P-Temp-500

Product application:
This high performance cable is designed to operate under more arduous high temperature conditions,
providing moisture resistance, toughness, flexibility and a continous conductor operating temperature of
450C.

Product characteristic:
Construction:
Fine nickel plated copper wire strands
Glass fiber woven mica tape
Varnished color glass fiber woven mica tape for insulation
Mica tape, impregnated and varnished glass fibre braid for outer sheath
Standard colour is white, other colours to special order
Technical:
Working voltage :300/500V
Temperature range: Continious 500C
Core concentricity: 70%
Properties:
Good flexibility installation
Service temperature upto 500C
Good resistance to high temperature, oil and chemical
Good resistance to abrasion or mechanical damage

62

Caledonian High Temperature Cables

High Temperature P-Temp-500 Cable


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Product specification:

AWG

Strand x
Diameter
mm

Conductor Cross
Section
mm

20
18
17
16
14
12
10
8
6
6
4
4
2
1
1
2/0
2/0
3/0

7 0.3
11 0.3
14 0.3
21 0.3
35 0.3
56 0.3
84 0.3
84 0.4
228 0.3
126 0.4
196 0.4
361 0.3
494 0.3
396 0.4
703 0.3
551 0.4
988 0.3
760 0.4

0.5
0.75
1
1.5
2.5
4
6
10
16
16
25
25
35
50
50
70
70
95

Nominal
Insulation
Thickness
mm
0.5
0.5
0.5
0.5
0.6
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1
1.2
1.2
1.2
1.2
1.2

Nominal
Diameter over
Single Core
mm
2.3 0.3
2.5 0.3
2.6 0.3
2.9 0.3
3.6 0.5
4.7 0.5
5.5 0.5
6.6 0.5
7.8 0.5
7.8 0.5
9.5 0.5
9.5 0.5
11.2 1.0
13.2 1.0
13.2 1.0
15.4 1.0
15.4 1.0
17.4 1.0

*other specifications are available upon request

63

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

PVC Flatform Cable

Product application:
Suitable in dry, wet and moist rooms and are used is conveyor and hoisting equipment etc, and as feed
cable for mobile machine components.

Product characteristic:
Construction :
Bare copper conductor
Structure according to VDE 0295, class 5
PVC insulation
Core marking :
up to 5 cores colour coded in accordance to VDE 0293;
7 cores and more black with printed consecutive number coding
Earth conductor green / yellow
PVC outer sheath / black
Flame retardant
Technical:
Bending radius 10 x
o
o
Temperature range flexing : - 15 C to + 70 C

Static : - 30oC to + 70oC

64

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Product specification:
AWG
17
17
17
17
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
8
8
6
4
2
1
2/0

No. of
Cores
12
16
20
24
4
5
7
8
10
12
18
24
4
5
7
8
10
12
24
4
5
7
4
5
4
4
4
4
4

Conductor
cross section
mm2
1
1
1
1
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
10
10
16
25
35
50
70

Outer Diameter
mm
35 x 1.3
46 x 4.3
57 x 4.3
68 x 4.3
14.5 x 5.2
17.5 x 5.2
25.3 x 5.2
25.3 x 5.2
27.3 x 5.2
40.8 x 5.2
61.8 x 5.2
83 x 5.2
17.5 x 5.9
21.1 x 5.9
31.1 x 5.9
33.1 x 5.9
42.6 x 5.9
49.1 x 5.9
102 x 5.9
20 x 6.9
26 x 6.9
35.3 x 6.9
27.6 x 9.3
37.5 x 11
43.5 x 11.2
41.2 x 13
49.6 x 14.5
58.4 x 17.5
63 x 20

Gross Copper
Weight
kg / km
115
154
192
230
58
72
101
115
144
173
259
346
96
120
168
192
240
288
480
154
192
269
384
480
768
960
1340
1920
2688

Gross
Weight
kg / km
392
521
642
772
130
160
230
260
320
385
665
820
190
235
340
370
515
560
1220
270
280
480
580
1120
1180
1340
1800
2520
3670

65

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

Neoprene Flatform Cable

Product application:
Neoprene sheathed flat cables are weatherproof and thus suitable for use under adverse ambient
conditions, e.g. for outdoor installation in shipyards, on cranes an on hoisting gear and conveyor
systems, for example.Used up to mean mechanical strain and severe bending load along a single level
during operation.

Product characteristic:
Construction
Bare copper conductions
Structure according to VDE 0295, class 5 or 6
Rubber insulated cores
Core marking :
up to 5 cores colour coded in accordance to VDE 0293;
7 cores and more black with printed consecutive number coding
Earth conductor green / yellow
Neoprene outer sheath / black
Flame retardant
Technical:
Bending radius 10 x
o
o
Temperature range flexing : - 25 C to + 70 C

Static : - 40oC to + 80oC

66

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Product specification:
AWG

No. of
Cores

Conductor
Cross Section
mm2

Outer Diameter
mm

Gross
Copper Weight
kg / km

Gross
Weight
kg / km

16
16
16
16
16
16
14
14
14
14
14
14
14
12
12
12
10
10
10
8
8
6
6
4
4
4
2
2
1
2/0
3/0
4/0

4
5
7
8
10
12
4
5
7
8
10
12
24
4
5
7
4
5
7
4
5
4
5
4
5
7
4
7
4
4
4
4

1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
6
6
6
10
10
16
16
25
25
25
35
35
50
70
95
120

163. x 5.5
21 x 5.5
27.1 x 5.5
30.2 x 5.5
38.5 x 6.1
44.7 x 6.1
19.7 x 6.8
25 x 6.8
32.6 x 6.8
36.4 x 6.8
47 x 7.7
54.6 x 7.4
71 x 14.5
24.6 x 8.7
31.2 x 8.7
40.8 x 8.4
27.2 x 9
34.6 x 9
45.4 x 9
32.8 x 10.5
44 x 11.8
38.1 x 12.2
50 x 13.6
44.5 x 13.8
60 x 16.3
77.7 x 15
51 x 15.8
87.5x 16.4
59.9 x 18.4
68 x 20.8
77.3 x 23.5
89.5 x 28.2

58
72
101
115
144
173
96
120
168
192
240
288
576
154
192
269
230
288
403
384
480
614
768
960
1200
1680
1344
2352
1920
2688
3648
4608

167
216
287
323
447
524
256
328
439
495
565
799
1614
395
529
681
501
652
866
750
1000
1083
1450
1522
2200
2845
2065
3770
2896
3887
5117
6809

67

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

TML Cable - Type A for Process Water,


Type B Drinking Water

Product application :
As connection cable for submersible electric motors (pumps) for the permanent use in process and
drinking water up to a temperature of 70oC. In addition DIN VDE 0298 T.300 has to be respected.

Product characteristic:
Construction:
Fine stranded bare copper conductor
EPR insulation
EPR outer sheath
Technical:
Characteristics at 20oC:
Rated voltage : 600/1000V
Maximum admissible operating voltage:
in 1 ph and 3 ph systems : 720 / 1200V
in D C systems : 1800 V
conductor resistance to DIN / VDE 0295
Test voltage 50Hz, 5 min : 2500 V
Temperature range:
o
Maximum admissible conductor temperature in operation 90 C
o
Short circuit temperature 250 C
o
o
o
o
Fixed : -40 C up to + 80 C In motion : -25 C up to + 80 C

Tensile stress : maximum 15 N each sqmm conductor cross sectio

68

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Properties:
Adapted to DIN VDE 0250 and DIN VDE 0282
Excellent insulation properties in water
Very low water absorption
Preservation of the mechanical strength
BAM* certificate VI.31/10904/01 - confirming the suitability of TML type B in drinking water.

Product specification:
AWG

No. of
Cores

16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
300kcmil
350kcmil
16
14
12
10
8
6
4

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2

Conductor
cross section
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25

O .D. mm
Min - Max.
5.8
7.2
6.4
8
7.4
9
8
11
9.8
12.5
11
14.5
12.5
16.5
14
18.5
16.5
21
18.5
23.5
21
26
23.5
28.5
26
31.5
27.5
34.5
30.5
38
33.5
41.5
9
11.5
10.5
13.5
12
15
13.5
18.5
18.5
24
21
27.5
25
31.5

Gross Copper
weight
kg/km
14.4
24
38
58
96
154
240
336
480
672
912
1152
1440
1776
2304
2880
29
48
77
115
192
307
480

Gross
Weight
kg/km
54
76
105
135
200
290
410
560
740
1000
1300
1650
2000
2500
3100
3700
130
190
260
350
550
900
1300

69

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

AWG

No. of
Cores

16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6
4
2
1
2/0
3/0
4/0
16
14
12
10
8
6

3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5

70

Conductor
cross section
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
1.5
2.5
4
6
10
16

O .D. mm
Min - Max.
9.6
12.5
11.5
14.5
13
16
14.5
20
20
25.5
22.5
29.5
26.5
34
29.5
38
34.5
44
39
49.5
44
54.6
47.5
59
10.5
13.5
12.5
15.5
14.5
18
16.5
22
22.5
24.5
26.5
28.5
32
34
33
42.5
38
48.5
43
54.5
50
60.5
53
65.5
11.5
15
13.5
17
16
19.5
18
24.5
24
30.5
27
35.5

Gross Copper
weight
kg/km
43
72
115
173
288
461
720
1008
1440
2016
2736
3456
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
72
120
192
288
480
768

Gross
Weight
kg/km
150
220
340
480
750
1100
1450
2100
2800
3800
4600
5400
190
280
390
520
950
1400
1950
2700
3600
4900
6200
7200
230
340
470
640
1150
1700

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

TML Cable Flat - Type A for Process


Water, Type B for Drinking Water

Product application :
As connection cable for submersible electric motors (pumps) for the permanent use in process and
drinking water up to a temperature of 70oC.

Product characteristic:
Construction:
Fine stranded bare copper conductor
EPR insulation
EPR outer sheath
Technical:
Characteristics at 20oC:
Rated voltage : 600/1000V
Maximum admissible operating voltage:
in 1 ph and 3 ph systems : 720 / 1200V
in D C systems : 1800 V
conductor resistance to DIN / VDE 0295
Test voltage 50Hz, 5 min : 2500 V

Temperature range:
o
Maximum admissible conductor temperature in operation 90 C
o
Short circuit temperature 250 C
o
o
o
o
Fixed : -40 C up to + 80 C In motion : -25 C up to + 80 C

Tensile stress : maximum 15 N each sqmm conductor cross section

71

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

Properties:
Adapted to DIN VDE 0250 and DIN VDE 0282
Excellent insulation properties in water
Very low water absorption
Preservation of the mechanical strength
BAM* certificate VI.31/10904/01 - confirming the suitability of TML type B in drinking water.

Product specification:
AWG

No. of
Cores

16
14
12
10
8
6
4
2
1
2/0
3/0
16
14
12
10
8
6
4
2
1

3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4

72

Conductor
cross section
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
1.5
2.5
4
6
10
16
25
35
50

Outer Diameter
mm x mm
13 x 7
16 x 8
19 x 9
23 x 10
28 x 12
31 x 14
37 x 17
38 x 17
45 x 20
52 x 22
58 x 25
17 x 7
20 x 8
24 x 9
26 x 10
31 x 11
36 x 13
45 x 15
48 x 17
59 x 20

Gross
Copper weight
kg/km
43
72
115
173
288
461
720
1008
1440
2016
2736
58
96
154
230
384
614
960
1344
1920

Gross weight
kg / km
125
185
290
400
620
900
1150
1550
2200
2900
3800
160
250
340
450
850
1200
1600
2100
2900

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

Siliconresinhigh-temperaturewire

Product application:
These cable are applied to high temperature situation such as electrons , family machines, lighting
lamps, inner of burning machinery, and so on

Product characteristic:
Construction
Tin-plated,nickel-plated and silver-plated copper wire conductor
Silicon resin isolation
Technical:
Nominal voltage : 600V
o
o
Temperature range: -600 C ~+2000 C

Properties:
Outstanding insulation property, high-and-low-temperatureresistance,coronaandelectricarc
resistance, water-proof.
Outstanding resistance to weather-aging, ozone and chemicals.
With silicone resin, the H-grade motor, other electric appliances would be size-small, weight-light,
last-long and could be used under harsh environment.
When over loaded, the motor or other electric appliance would not go out of order and wouldnot
burn heavily. The gasses giving off are not poisonous. The remains after burning is silicon dioxide.

73

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk

Product specification:

AWG
26
24
22
20
18
16
14
12
24
24
22
22
20
20
18

74

Conductor
Nominal
Conductor
cross
construction
section
No./mm
mm2
0.128
7/0.16
0.205
7/0.20
0.324
7/0.26
0.519
7/0.32
0.823
7/0.40
1.31
7/0.50
2.08
41/0.254
3.31
19/0.50
0.2
1/0.50
0.2
12/0.15
0.3
1/0.62
0.3
17/0.15
0.5
1/0.80
0.5
28/0.15
0.75
1/1.0

Isolation
Nominal
thickness
mm

Nominal
O.D.
mm

Max
O.D.
mm

0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.78

2.1
2.2
2.4
2.5
2.8
3.1
3.6
4.1
2.2
2.2
2.3
2.3
2.5
2.5
2.8

2.3
2.4
2.6
2.7
3
3.3
3.8
4.3
2.4
2.4
2.5
2.5
2.7
2.7
3

Max
conductor
resistance
in 20oC
/km
143
92
56.8
40.1
23
14.6
9.9
5.4
95
95
71.2
71.2
40.1
40.1
26.7

Gross
Weight
kg/km
4.6
5.7
8.3
10.4
14.6
20
27
36
5.9
5.9
7.2
7.2
10.1
10.1
13.2

Caledonian High Temperature Cables

High Temperature Special Cables


www.caledonian-cabes.co.uk
www.caledonian-cabes.co.uk

75

Caledonian High Temperature Cables

High Temperature
Caledonian
Cables Ltd Special Cables

www.caledonian-cabes.co.uk

Merchant Ind. Centre


Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ
England
United Kingdom
44- 207- 4195087
Fax: 44- 207- 8319489
Email: sales@caledonian-cables.co.uk
sales@caledonian-cables.com
uk@addison-tech.com

Caledonian Cables Ltd


Merchant Ind. Centre
Mill-Lane, Laughton, Lewes, Sussex, BN8 6AJ
England
United Kingdom
44- 207- 4195087
Fax: 44- 207- 8319489
Email: sales@caledonian-cables.com
sales@caledonian-cables.co.uk
uk@addison-tech.com
76

Vous aimerez peut-être aussi