SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE

(SUPPLIED BY VACKER, DUBAI)


Model no:

TTR 55 E

TTR 56 E

17 Sep 2015

TTK 24 E

TTK 25 E

TTK 29 E

8.56
10

10
12

8.56
10

100

50

110

37

37

37

5
32

5
35
30
100

5
32

230
50
0.25
1.2

230
50
0.2

230
50
0.25
1.2

Image

Video
Dehumidification performance
At 30 C / 80 % RH [l/24h]
8.5
8.5
Max. [l/24h]
8.7
9
Amount of air
Max. air volume [m/h]
160
200
Recommended room size for construction drying
Size of room m
Recommended room size for home / office for dry keeping
Size of room m
50
50
Surrounding conditions
Temperature range min. [C]
1
0
Temperature range max. [C]
35
32
Humidity range min. [% RH]
45
35
Humidity range max. [% RH]
100
90
Electrical values
Input voltage [V]
230
230
Frequency [Hz]
50
50
Max. power input [kW]
0.63
0.78
Nominal current consumption [A]
Recommended fusing [A]
10
Compressor

10

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

17 Sep 2015

TTR 55 E

TTR 56 E

TTK 24 E

TTK 25 E

TTK 29 E

Rotary piston
compressor
R134a

Rotary piston
compressor
R134a

Rotary piston
compressor
R134a

Rotary piston
compressor
R-134a

Rotary piston
compressor
R134a

3.5

1.6

2.3

2.3

54

54

42

43

43

180
300
480

200
445
525

312
243
417

230
230
386

365
220
490

6.8

8.5

10.1

8.5

11.1

Image

Video
Type of compressor
Type of cooling agent
Water tank
Water tank [L]
Sound values
Sound level [dB(A)] at 1 m
Dimensions (packing excluded)
Length [mm]
Width [mm]
Height [mm]
Weight (packing excluded)
Weight [kg]
Vacker Group
306, RKM Building, Deira, Dubai, UAE
T: +971 42 66 11 44
sales.uae@vackerglobal.com
www.vackergroup.ae

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

TTK 30 S

TTK 31 E

TTK 40 E

17 Sep 2015
TTK 50 E

TTK 51 E

12
14

14
16

14.7
16

100

100

126

63

78

78

5
35
30
100

5
35
40
100

5
32
30
90

230
50
0.34

230
50
0.25

230
50
0.41
2.1

10

10

Image

Video
Dehumidification performance
At 30 C / 80 % RH [l/24h]
10
10
Max. [l/24h]
12
12
Amount of air
Max. air volume [m/h]
100
120
Recommended room size for construction drying
Size of room m
Recommended room size for home / office for dry keeping
Size of room m
37
37
Surrounding conditions
Temperature range min. [C]
5
5
Temperature range max. [C]
35
35
Humidity range min. [% RH]
49
49
Humidity range max. [% RH]
100
100
Electrical values
Input voltage [V]
230
230
Frequency [Hz]
50
50
Max. power input [kW]
0.21
0.24
Nominal current consumption [A]
1.05
Recommended fusing [A]
10
10
Compressor

http://bit.ly/1MuUIXK

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
TTK 30 S

Model no:

TTK 31 E

TTK 40 E

17 Sep 2015

TTK 50 E

TTK 51 E

Image

Video
Type of compressor
Type of cooling agent
Water tank
Water tank [L]
Sound values
Sound level [dB(A)] at 1 m
Dimensions (packing excluded)
Length [mm]
Width [mm]
Height [mm]
Weight (packing excluded)
Weight [kg]
Vacker Group
306, RKM Building, Deira, Dubai, UAE
T: +971 42 66 11 44
sales.uae@vackerglobal.com
www.vackergroup.ae

http://bit.ly/1MuUIXK
Rotary piston
compressor
R-134a

Rotary piston
compressor
R134a

Rotary piston
compressor
R-134a

Rotary piston
compressor
R-134a

Rotary piston
compressor
R134a

1.6

1.6

3.5

3.5

2.3

40

45

43

40

43

310
160
510

160
320
500

225
353
496

220
310
540

365
220
490

9.1

10.5

11.1

13.8

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

TTK 70 E

TTK 70 S

17 Sep 2015

TTK 71 E

TTK 75 E

TTK 75 S

20
24

18.2
20

20
24

180

192

180

125

110

125

5
35
49
100

5
35
40
100

5
35
49
100

230
50
0.44
1.05
10

230
50
0.32

230
50
0.33

10

10

Image

Video
Dehumidification performance
At 30 C / 80 % RH [l/24h]
18.6
20
Max. [l/24h]
20
24
Amount of air
Max. air volume [m/h]
135
150
Recommended room size for construction drying
Size of room m
Recommended room size for home / office for dry keeping
Size of room m
110
125
Surrounding conditions
Temperature range min. [C]
5
5
Temperature range max. [C]
32
35
Humidity range min. [% RH]
30
49
Humidity range max. [% RH]
90
100
Electrical values
Input voltage [V]
230
230
Frequency [Hz]
50
50
Max. power input [kW]
0.48
0.4
Nominal current consumption [A]
2.2
Recommended fusing [A]
10
Compressor

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

17 Sep 2015

TTK 70 E

TTK 70 S

TTK 71 E

TTK 75 E

TTK 75 S

Rotary piston
compressor
R143a

Rotary piston
compressor
R-134a

Rotary piston
compressor
R-134a

Rotary piston
compressor
R-410A

Rotary piston
compressor
R-134a

2.3

3.6

45

48

50

42

40

365
220
490

378
185
582

220
350
550

245
340
570

300
350
585

13.7

12.4

11.4

12.3

12.8

Image

Video
Type of compressor
Type of cooling agent
Water tank
Water tank [L]
Sound values
Sound level [dB(A)] at 1 m
Dimensions (packing excluded)
Length [mm]
Width [mm]
Height [mm]
Weight (packing excluded)
Weight [kg]
Vacker Group
306, RKM Building, Deira, Dubai, UAE
T: +971 42 66 11 44
sales.uae@vackerglobal.com
www.vackergroup.ae

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

TTK 90 E

TTK 100 E

17 Sep 2015

TTK 100 S

TTK 105 S

TTK 120 S

28.4
30

28.4
30

27
35

200

240

510

112,5

112,5

120

230

230

238

5
35
40
100

5
35
30
100

5
43
40
100

230
50
0.53
3.6
10

230
50
0.52

230
50
0.4
2.1
10

Image

Video
Dehumidification performance
At 30 C / 80 % RH [l/24h]
28.4
25
Max. [l/24h]
30
30
Amount of air
Max. air volume [m/h]
240
200
Recommended room size for construction drying
Size of room m
Recommended room size for home / office for dry keeping
Size of room m
230
230
Surrounding conditions
Temperature range min. [C]
5
5
Temperature range max. [C]
35
35
Humidity range min. [% RH]
30
40
Humidity range max. [% RH]
100
100
Electrical values
Input voltage [V]
230
230
Frequency [Hz]
50
50
Max. power input [kW]
0.52
0.53
Nominal current consumption [A]
2.9
Recommended fusing [A]
10
10
Compressor

10

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

17 Sep 2015

TTK 90 E

TTK 100 E

TTK 100 S

TTK 105 S

TTK 120 S

Rotary piston
compressor
R-410A

Rotary piston
compressor
R-410A

Rotary piston
compressor
R-410A

Rotary piston
compressor
R-410A

Reciprocating
piston
R-134a

5.2

4.3

4.3

5.2

50

46

46

55

59

253
340
540

290
390
612

290
390
612

250
342
517

362
380
605

13.6

15.2

15.2

14.5

23.5

Image

Video
Type of compressor
Type of cooling agent
Water tank
Water tank [L]
Sound values
Sound level [dB(A)] at 1 m
Dimensions (packing excluded)
Length [mm]
Width [mm]
Height [mm]
Weight (packing excluded)
Weight [kg]
Vacker Group
306, RKM Building, Deira, Dubai, UAE
T: +971 42 66 11 44
sales.uae@vackerglobal.com
www.vackergroup.ae

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

TTK 120 E

TTK 122 E

Image

Video
Dehumidification performance
At 30 C / 80 % RH [l/24h]
28
38
Max. [l/24h]
30
40
Amount of air
Max. air volume [m/h]
340
350
Recommended room size for construction drying
Size of room m
120
175
Recommended room size for home / office for dry keeping
Size of room m
238
300
Surrounding conditions
Temperature range min. [C]
9
9
Temperature range max. [C]
35
35
Humidity range min. [% RH]
40
40
Humidity range max. [% RH]
100
100
Electrical values
Input voltage [V]
230
230
Frequency [Hz]
50
50
Max. power input [kW]
0.6
0.7
Nominal current consumption [A]
Recommended fusing [A]
10
10
Compressor

17 Sep 2015

SELECTION GUIDE FOR DEHUMIDIFIERS FOR HOME AND OFFICE USE


(SUPPLIED BY VACKER, DUBAI)
Model no:

TTK 120 E

TTK 122 E

Reciprocating
piston
R-134a

Reciprocating
piston
R-134a

10

10

47

49

310
435
650

310
435
650

22.3

22.9

Image

Video
Type of compressor
Type of cooling agent
Water tank
Water tank [L]
Sound values
Sound level [dB(A)] at 1 m
Dimensions (packing excluded)
Length [mm]
Width [mm]
Height [mm]
Weight (packing excluded)
Weight [kg]