Vous êtes sur la page 1sur 25

Huawei XL LTE 1800 MHz SOP Implementation

www.huawei.com
www.huawei.com

Software version
SRAN9.0

NE Name

NE Count Target Version (R&D

BSC6900 GO

BSC6900V900R016C00SPC620

BSC6900 UO

BSC6900V900R016C00SPC620

BTS3900A_GSM

BTS3900 V100R009C00SPC186

BTS3900L_GSM

BTS3900 V100R009C00SPC186

M2000

V200R014C00SPC210

CME

V200R014C00SPC210

Huawei Confidential

Page 2

On Site Operation Process


On site Team :
1. Insert UMPT or replace GTMU with UMPT
2. Insert UBBP slot 3 for GSM only, and slot 2 if WBBP exist in slot 3
3. Upgrade cabinet to Ver. D if scenario using MRFUd, then continue install MRFUd 1800 Mhz
4. Install RRU 3939 if scenario using RRU
5. Reroute CPRI connection based on scenario implementation
6. Cut over transmission to UMPT and new port on RTN/MSTP
7. Download BTS3900 V100R009C00SPCXXX to UMPT (25 minutes)
8. Activate software (10 minutes)
9. SPL software (5 minutes)
10. Download script
11. Activate script
12. Inform to monitoring team whether OM has been Ok or not
13. Dismantle unused materials
Monitoring Team :
1. Delete original NE GBTS , Then synchronize NE on U2000
2. Activate eGBTS license dan eNodeB license
3. If existing has 3G, ask RTN/TRM team to reroute IuB vlan service
Huawei Confidential

Page 3

Download software to UMPT (20 menit)


Make sure SFTP is running.
Double click application below :

Setting IP Laptop: 192.168.0.50 (or 17.21.2.XX)


Login via Internet Explorer :
IP
: 192.168.0.49 (or 17.21.2.15)
User name : admin
Password : hwbs@com (or NodeB)

Huawei Confidential

Page 4

Download software to UMPT (25 minutes)


DLD SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900
V100R009C00SPC170_ALL(Software)", SWT=SOFTWARE, SV="D:\BTS3900V100R009C00SPC170", DC=NO,
ATL=GBTS&NodeB;

FTP Server IP = IP Laptop


Directory Name : address where we save the software
Huawei Confidential

Page 5

Activate Software (10 minutes)


ACT SOFTWARE: OT=NE, SWT=SOFTWARE, SV="BTS3900V100R009C00SPC170", ATL=GBTS&NodeB;

Huawei Confidential

Page 6

SPL Software (5 Minutes)


SPL SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900
V100R009C00SPC170_ALL(Software)", SDL=YES;

Verify SPL software :


Run MML command DSP GLOCELL
If the MML is not appear, it means SPL software has not succeed

Huawei Confidential

Page 7

Software Verification
DSP APP:;

Huawei Confidential

Page 8

Download script
DLD CFGFILE: IP="192.168.20.48", USR="admin", PWD="*****", DIR="E:\compt",
FN="E720G_3G_KESAWAN_FullExport_20141124022032";

Huawei Confidential

Page 9

Activate script
ACT CFGFILE: EFT=AFTER_RESET;

Then Reset UMPT board (From LMT / plug-unplug)

Huawei Confidential

Page 10

Check Software Version and Cell Service


LST VER :;
DSP APP:;
DSP LICENSE: FUNCTIONTYPE=GBTS;
DSP LICENSE: FUNCTIONTYPE=NodeB;
DSP LICINFO:;
CHK DATA2LIC:;
LST ULOCELL: MODE=ALLLOCALCELL; //3G Cell
DSP GLOCELL:; //2G Cell
DSP CELL:; //LTE Cell
Monitor Channel Status and Traffic
Huawei Confidential

Page 11

BBU Solution
GSM Only
Before

After
- ADD UMPTb1 (slot 7)
- ADD UBBPd3 (Slot 3)
- ADD UBRI (Optional)

Huawei Confidential

Page 12

BBU Solution
GU Co-Cabinet
Before

After

- ADD UMPTb1 (slot 7)


- Move WBBP slot 2 to
slot 4
- ADD UBBPd3 (Slot 2)
- ADD UBRI (Optional)

Huawei Confidential

Page 13

RF Solution

Huawei Confidential

Page 14

Scenario 1: Existing site is G900 only

Existing :
- 3 MRFU V2 900MHz
- BBU Box : GTMU
BEFORE

Solution :
- Keep GTMU
- Add DCDU-12B + 3 RRU 3939 (LO)
- Add UMPTb1 (LTE Only) slot 7
- Add UBBPd6 slot 3

Huawei Confidential

Page 15

Scenario 1: Existing site is G900 only

Existing :
- 3 MRFU V2 900MHz
- BBU Box : GTMU
AFTER

Solution :
- Keep GTMU
- Add DCDU-12B + 3 RRU 3939 (LO)
- Add UMPTb1 (LTE Only) slot 7
- Add UBBPd6 slot 3

Huawei Confidential

Page 16

Scenario 2: Existing site is D1800 only

Existing :
- 3 MRFU V2 1800MHz or RRU 3926 V3
- BBU Box : GTMU
BEFORE

Solution :
- Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800
- Add UMPTb1 GL co-MPT slot 7
- Add UBBPd3 to slot 3
-Dismantle RRU 3926 / MRFU V2 1800
-Dismantle GTMU
-CPRI MUX from UBBPd3 to RRU 3939

Huawei Confidential

Page 17

Scenario 2: Existing site is D1800 only

Existing :
- 3 MRFU V2 1800MHz or RRU 3926 V3
- BBU Box : GTMU
AFTER

Solution :
- Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800
- Add UMPTb1 GL co-MPT slot 7
- Add UBBPd3 to slot 3
-Dismantle RRU 3926 / MRFU V2 1800
-Dismantle GTMU
-CPRI MUX from UBBPd3 to RRU 3939

Huawei Confidential

Page 18

Scenario 3: Existing site is G900 + D1800


Existing :
-3 MRFU V2 900MHz + 3 MRFU V2 1800MHz
-BBU Box : GTMU
BEFORE

Solution :
- Add DCDU-12B + 3 RRU 3939 (GL)
- Add UMPTb1 GL co-MPT slot 7
- Add UBBPd3 to slot 3
-dismantle MRFU V2 OL1
-Keep GTMU for UL interface only
-CPRI MUX from UBBPd3 to RRU 3939

Huawei Confidential

Page 19

Scenario 3: Existing site is G900 + D1800


Existing :
-3 MRFU V2 900MHz + 3 MRFU V2 1800MHz
-BBU Box : GTMU
AFTER

Solution :
- Add DCDU-12B + 3 RRU 3939 (GL)
- Add UMPTb1 GL co-MPT slot 7
- Add UBBPd3 to slot 3
-dismantle MRFU V2 OL1
-Keep GTMU for UL interface only
-CPRI MUX from UBBPd3 to RRU 3939

Huawei Confidential

Page 20

Scenario 4: Existing site is G900 + U2100


Existing :
-3 MRFU V2 900MHz + 3 WRFU / RRU 3839
-BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
BEFORE

Solution :
- Add DCDU-12B + 3 RRU 3939
- Replace GTMU with UMPTb1 (GL co-MPT) slot 6
- Move existing WBBP slot 2 to slot 4
-Insert UBBPd3 in slot 2
- dismantle GTMU

Huawei Confidential

Page 21

Scenario 4: Existing site is G900 + U2100


Existing :
-3 MRFU V2 900MHz + 3 WRFU / RRU 3839
-BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
AFTER

Solution :
- Add DCDU-12B + 3 RRU 3939
- Replace GTMU with UMPTb1 (GL co-MPT) slot 6
- Move existing WBBP slot 2 to slot 4
-Insert UBBPd3 in slot 2
- dismantle GTMU

Huawei Confidential

Page 22

Scenario 5: Existing site is D1800 + U2100


Existing :
-3 MRFU V2 1800MHz + 3 WRFU / RRU 3839
-BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
- BTS3900A Cabinet ver.B
BEFORE

Solution:
- Swap cabinet to Ver.D
- Replace MRFU V2 to MRFUd 1800 (GL SDR)
- Replace GTMU to UMPTb1 (GL co-MPT) slot 6
- Move existing WBBP slot 2 to slot 4
-Add UBBPd3 to slot 2
-CPRI MUX from UBBPd3 to MRFUd 1800
-Dismantle GTMU
- dismantle old cabinet OL1

Huawei Confidential

Page 23

Scenario 5: Existing site is D1800 + U2100


Existing :
-3 MRFU V2 1800MHz + 3 WRFU / RRU 3839
-BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
- BTS3900A Cabinet ver.B
AFTER

Solution:
- Swap cabinet to Ver.D
- Replace MRFU V2 to MRFUd 1800 (GL SDR)
- Replace GTMU to UMPTb1 (GL co-MPT) slot 6
- Move existing WBBP slot 2 to slot 4
-Add UBBPd3 to slot 2
-CPRI MUX from UBBPd3 to MRFUd 1800
-Dismantle GTMU
- dismantle old cabinet OL1

Huawei Confidential

Page 24

HISILICON SEMICONDUCTOR