Alarms In NOKIA FLEXI BTS

BY :
KETANKUMAR WANKHEDE

1.)

7401 Alarm

Syntex
Type
Severity
Colour
Pin
Root

Mains Failure
N/C
Major
Green & Green/White
7, 25
PIU

DDF

BTS

Root cause Alarm occurs when there is no AC power supply


on site
Cause
1. AC gets failure due to regular AC cut.
2. AC gets failure due to any s/c.
3. AC gets failure due to any o/c.
Verification
To check the alarm Switch off the mains
MCB from PIU.
To remove alarm turn on the mains mcb.

2.)

7402 Alarm

Syntex
Type
Severity
Colour
Pin

Rectifier Fail
N/O
Minor
Blue & Blue /White
8, 26

Root

Alarm panel
Of P.P.

DDF

BTS

Root cause Alarm occurs when any one of the SMPS gets
failure.
Cause
1. Any SMPS gets failure.
2. Due to failure of MCB.
3. Due to any s/c.
Verification
To check the alarm firstly remove the
rectifier from the SMPS or switch off the
MCB of rectifier from SMPS.
To remove alarm switch on the.MCB of
the rectifier moduleor insert the new
rectifier module.

3.)

7403 Alarm

Syntex
Type
Severity
Colour
Pin
Root

Low Battery Voltage


N/O
Criticle
Violet & Violet /White
9, 27
Alarm panel
Of P.P.

DDF

BTS

Root cause Alarm occurs when Battery voltage reaches


46V/47V.
Cause
1. When AC gets failure and D.G. is not
working & site on battery from last 3-4 hrs.
2. When Battery is not fully charged and load
on battery.
Verification
To check the alarm set the o/p load vtg of
battery less then 48V & switch off the MCB
& D.G..
To remove alarm switch on the.MCB
(mains) or switch on the D.G. if AC is not
available.

4.)

7404 Alarm

Syntex
Type
Severity
Colour
Pin
Root

Site On Battery
N/O
Major
Gray & Gray /White
10, 28
Alarm panel
Of P.P.

DDF

BTS

Root cause Alarm occurs when all SMPS & Rectifiers gets
failure.
Cause
1. When AC gets failure and D.G. does not
start.
2. AC gets fail DG is off.
3. DG is not working properly.
4. AC gets failure & DG is not available at
site.
5. All SMPS & rectifires gets failure.
Verification
To check the alarm switch off the mains
MCB from PIU & switch off DG also.
To remove alarm switch on the mains
MCB or DG (if mains is not available).

5.)

7405 Alarm

Syntex
Type
Severity
Colour
Pin

Site On DG
N/O
Minor
Pink & Pink /White
11, 29

Root

PIU

DDF

BTS

Root cause Alarm occurs when load of site on DG.


Cause
1. When AC gets failure due to cutting time.
2. AC gets fail due to s/c.
3. MCB gets failure.
Verification
To check the alarm switch off the mains
MCB from PIU & switch on the DG (if it is
not in auto mode).
To remove alarm switch on the mains
MCB (if mains is available).

6.)

7406 Alarm

Syntex
Type
Severity
Colour
Pin
Root

DG LLOP
N/O
Criticle
Light Green & Black /Green
12, 30
LLOP Sensor
BTS

PIU

DDF

Root cause Alarm occurs when lube oil pressure gets below
then specified level.
Cause
1. Due to leakage of lubricant.
2. Due to overflow of lubricant.
3. Due to no service on time.
4. Due to no oil change on the time.
Verification
To check the alarm switch off the mains
MCB from PIU & switch off the DG also.
To remove alarm maintain the lubricant
oil pressure till specified level.

7.)

7407 Alarm

Syntex
Type
Severity
Colour
Pin
Root

Low Fuel Level


N/O
Minor
Light Blue & Black /Blue
13, 31
Fuel Sensor
BTS

PIU

DDF

Root cause Alarm occurs when fuel level goes below then
40% of the capacity.
Cause
1. When site on DG from long time.
2. When fuel tank is not fully filled.
3. Tank have leakage.
Verification
To check the alarm see if the desired fuel
level of DG is set on 40% or not.
To remove alarm fill the tank of DG.

8.)

7408 Alarm

Syntex
Type
Severity
Colour
Pin
Root

DG Fails To Start
N/O
Major
White & Black /White
13, 31
PIU

DDF

BTS

Root cause Alarm occurs when PIU is not able to start DG in


3 attempts.
Cause
1. Due to problem in self.
2. Self battery is not charge.
3. No fuel in DG.
4. No connection b/w PIU & Self.

Verification

9.)

To check the alarm switch off the mains


mcb from PIU and check dg set is not in
auto mode or remove the connection b/w
PIU and Self.
To remove alarm start DG in manual
mode.

7409 Alarm

Syntex
Type
Severity
Colour
Pin
Root

AC Failure
N/O
Major
Light Gray & Black /light gray
15, 33
C

DDF

BTS

Root cause Alarm occurs when both AC gets failure.


Cause
1. Due to problem in C.
2. Site on battery.
3. Level of gas in AC goes below then
the specified level.
4. Switching problem.
Verification
To check the alarm switch off the ACs.
To remove alarm switch
on/repair/replace ACs.

10.)

7410 Alarm

Syntex
Type
Severity
Colour
Pin

Door Open
N/C
Minor/Major/Criticle (Accd. to condition)
Red/ Black & Red/Blue
16, 34

Root
Door Sensor
BTS

PIU

DDF

Root cause Alarm occurs when Door is open.


Cause
1. Unauthorisd person is in the shelter.
2. Work on progress inside the shelter.
3. Someone (may be technician, engineer
or guard) forget to close the door.
4. Sealing of door is not proper.
5. Lock of door is not correct.
Verification
To check the alarm open the door.
To remove alarm close and seal proper
the door.

11.)

7411 Alarm

Syntex
Type
Severity
Colour
Pin
Root

High Room Temp.


N/O
Major
Orange/Red & orange/Light gray
16, 34
Temp.Sensor
BTS

c of AC

DDF

Root cause Alarm occurs when Temp reaches 35 c.


Cause
1. AC is not working.
2. Door of shelter is open.
3. Site on battery.
Verification
To check the alarm rub thermister in b/w
hands .
To remove alarm switch on the AC & set
AC temp on desired value.

12.)

7412 Alarm

Syntex
Type
Severity
Colour
Pin
Root

Fire & Smoke.


N/O
Criticle
Orange/Black & Orange/Green
18, 36
F& S sensor
BTS

PIU

DDF

Root cause Alarm occurs when Fire & Smoke at site.


Cause
1. Fire & Smoke at site.
2. Due to any inflammable object at site.
Verification
To check the alarm create a small fire by
paper or jute.
To remove alarm Reset smoke & fire
sensor and clean the smoke from the
sensor.