Académique Documents
Professionnel Documents
Culture Documents
HF ELECTROSURGICAL UNIT
SURTRON
FLASH 200
The HF electrosurgical unit SURTRON FLASH 200 allows of to effect monopolar and bipolar electrosurgery.
The equipment can be used either with delivery time equal to that of activation of the output circuit, or with
programmable delivery time in the range from 1 ms up to 999 ms.
The programmed current pulse can be single or repeated by 1 to 250 times each second.
The presetting of the supply time can have effected both in the monopolar and bipolar mode of operation.
SURTRON FLASH 200 has a unit designed and produced by LED SpA, UNI EN ISO 9001 and UNI CEI EN 46001
certified firm.
Destination of use
The use of HF electro surgical equipment SURTRON FLASH 200 has reserved to specialized medical personnel. The
equipment has destined to a temporary use, for surgical operations in emergency room or hospital. It has foreseen its use
in the monopolar cut, cut coagulated or coagulation mode or in bipolar coagulation mode.
The technical solutions related to the deliverable currents make the unit advisable for the followings fields of use:
Casualty surgery
Vascular surgery
Plastic surgery
Dermatology
Endoscopy
Gastroenterology
Gynecology
Neurosurgery
Oculistics
Otorhinolaryngology
Pneumology
Urology
General surgery
Pediatric surgery
Orthopedics
IT0159GB rev. C
2/5
Load
Crest Factor
Max Voltage
Frequency
CUT 100%
200 W
250
1.5
1050 Vpp
600 kHz
CUT 90%
200 W
250
1.6
1050 Vpp
600 kHz
CUT 80%
200 W
250
1.7
1050 Vpp
600 kHz
CUT 70%
200 W
250
1.9
1050 Vpp
600 kHz
BLEND
120 W
200
2.1
1050 Vpp
600 kHz
FORCED COAG
150 W
150
2.0
1050 Vpp
600 kHz
SOFT COAG
90 W
100
1.7
540 Vpp
600 kHz
BIPOLAR
100 W
100
1.5
540 Vpp
600 kHz
I CF
Special system for plate to patient contact control that allows the use either of splitted
or not splitted neutral plates.
The circuit is able to check the efficiency of the plate-patient contact.
1 - 999 ms
Neutral electrode
Floating
Dimensions (H x L x D)
Weight
7.5 Kg
Mains Power
115-230Vac / 50-60Hz.
Duty Cycle
10 s / 30 s
10C - 40C
Relative humidity
30% - 75%
IT0159GB rev. C
3/5
Atmospheric pressure
IT0159GB rev. C
7= OPTIONAL
description
SURTRON
FLASH 200
10300.40A
2/1
2/5
7
7
7
7
2/1
2/1
7
7
7
7
7
7
7
7
7
2/3
7
7
7
7
7
2/3
7
2/3
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
2/1
2/2
2/2
7
7
7
7
2/1
7
2/1
7
4/5
code
0202/B
00201.00
2835A
BWA435-030
MA159
00300.00
00302.00
00301.03
BWA600-001
BWA600-040
00201.03
F7520
SURTRON
FLASH 200
description
Disposable handle without finger switches
Handle for microsurgical needle
Reusable handle with finger switches
Reusable handle without finger switches
Manual of instructions
Not waterproof foot switch
Waterproof foot switch
Double waterproof foot switch
Curved bipolar forceps 1mm x 195mm
Straight bipolar forceps 1mm x 195mm
Microsurgical handle holder
Electrode cleaning sponge
7
2/1
2/1
7
2/1
7
2/1
7
7
7
7
7
The characteristics and the technical data can be modified without warning.
LED SpA
PROGETTAZIONI E PRODUZIONI ELETTRONICHE
Via Selciatella, 40 I-04010 Aprilia (LT) ITALIA
Tel. +39 06 92870045 Fax +39 06 92870046
www.led.it
e-mail: export@led.it
IT0159GB rev. C
5/5