TECHNICAL INFORMATION

HF ELECTROSURGICAL UNIT

SURTRON
FLASH 200

The HF electrosurgical unit SURTRON FLASH 200 allows of to effect monopolar and bipolar electrosurgery.
The equipment can be used either with delivery time equal to that of activation of the output circuit, or with
programmable delivery time in the range from 1 ms up to 999 ms.
The programmed current pulse can be single or repeated by 1 to 250 times each second.
The presetting of the supply time can have effected both in the monopolar and bipolar mode of operation.
SURTRON FLASH 200 has a unit designed and produced by LED SpA, UNI EN ISO 9001 and UNI CEI EN 46001
certified firm.
Destination of use
The use of HF electro surgical equipment SURTRON FLASH 200 has reserved to specialized medical personnel. The
equipment has destined to a temporary use, for surgical operations in emergency room or hospital. It has foreseen its use
in the monopolar cut, cut coagulated or coagulation mode or in bipolar coagulation mode.
The technical solutions related to the deliverable currents make the unit advisable for the followings fields of use:

Casualty surgery
Vascular surgery
Plastic surgery

Dermatology
Endoscopy
Gastroenterology

Gynecology
Neurosurgery
Oculistics

Otorhinolaryngology
Pneumology
Urology

And usable besides for:

General surgery

Pediatric surgery

Orthopedics

Programmed supply of output power


The planning of the times of delivery and pause times allows to reduce the biological damage due to the treatment. This
permit:
to get samples for biopsy with reduced modification of the sample itself and reduced thermal damage to the tissue
object of the collecting;
to finish the coagulation automatically both in monopolar and bipolar mode of operation;
to perform treatments of micro oculistics or dermatological surgery.
Output power
For every method of use the level of the output power can be carefully preset with resolution as low as 1 Watt. This,
together to the possibility of timed delivery, allows the use of the equipment also for procedures requiring high
precision like oculistics or dermatology. For examples for treatments of telangiectasis, spider nevus etc.
The delivered output power is watched by microcontroller that prevents its level from being different of the preset
value.
Cut and Coagulated cut
The CUT mode delivers either pure sine current, that means current with no coagulating property, or current with
presettable degree of modulation, that allows four different values of crest factor with as many different degrees of
coagulation.
The value of the duty cycle of the delivered current has shown by bright digital display.
At the beginning of every cycle of modulation of the coagulated cut current, a peak of momentary higher voltage is
present that allows to improve the start of the cut by keeping track of the different impedance of the skin's surface.
The output of the cutting or of the coagulated-cutting current can be activated by handle or by pedal.
Mixed current
The BLEND mode delivers a special current for coagulated cut that allows to effect coagulated cut in total absence of
side carbonization.
This current, made by mixing cutting current and low voltage coagulating current (soft), it is particularly suitable to the
use in endoscopic surgery for procedures like polypectomy, prostatic resection (TURP), papillary resection, uterine
resection, endometrial ablation, etc.
Superficial coagulation
The FORCED COAG mode delivers the current traditionally used for coagulation, or rather sine current modulated in
such a way to get relatively high crest factor. It is characterized for its elevated coagulative power and suited for
superficial coagulation with production of moderate carbonization and eschara.
Deep coagulation
The SOFT COAG mode delivers low voltage sine current and therefore not suited to cut or to superficial coagulation
but useful to desiccate and to effect deep coagulation with very small necrosis of tissue. Using this type of current does
not produce carbonization and one gets more ready recovery than with other kinds of current.
Minimum Invasive Surgery
BIPOLAR COAG allows the use of bipolar forceps (using the adapter Ref.00498.04) for low voltage precise bipolar
coagulation. Minimum invasive surgery is also obtainable by the possibility to automatically alternate the delivery of
current with pauses, so to dissipate the heat produced for every active interval. To preset the expire time for the current
delivery automatically is also allowed.
Safety time of current delivery
After 10 seconds of continuous current delivery, an intermittent bright signal suggests to the operator to end the
operation in way to reduce the damage due to overheating to the patient. The delivery of current has interrupted
automatically, after a time depending from the delivered power and from the operative mode in use, if, despite the
warning signal, the current delivery has maintained for so long time that can be dangerous. In these circumstances,
besides the bright signal, an acoustic warning to the operator is given.

IT0159GB rev. C

2/5

Memorization of work conditions


The operational mode and the power level used in the last session are proposed automatically when the unit is switched
on for a new operation. Nine operative conditions more, can have stored and recalled by the operator.
Self analysis
Every time that the unit has turned on, an automatic control of its functionality and the conditions of the connected
accessories is effected and lacks of conformity signaled by coded messages.
Neutral electrode
The unit can use both neutral plates with single sector as well neutral plates split in two sectors.
Through a particular electronic circuit SKIN PLATE ELECTRONIC CONTROL the value of the impedance of the
circuit of the neutral electrode, and skin to plate contact, is shown to the operator which confirms the validity of it. The
value of impedance accepted is continually watched by the equipment's microcontroller and, if it changes more than
40%, the output of current is interdicted and an acoustic and bright signal warns the operator while the actual value of
impedance is shown.
Technical characteristics
Nominal
Power

Load

Crest Factor

Max Voltage

Frequency

CUT 100%

200 W

250

1.5

1050 Vpp

600 kHz

CUT 90%

200 W

250

1.6

1050 Vpp

600 kHz

CUT 80%

200 W

250

1.7

1050 Vpp

600 kHz

CUT 70%

200 W

250

1.9

1050 Vpp

600 kHz

BLEND

120 W

200

2.1

1050 Vpp

600 kHz

FORCED COAG

150 W

150

2.0

1050 Vpp

600 kHz

SOFT COAG

90 W

100

1.7

540 Vpp

600 kHz

BIPOLAR

100 W

100

1.5

540 Vpp

600 kHz

Electric Safety Class

I CF

Skin Plate Electronic Control

Special system for plate to patient contact control that allows the use either of splitted
or not splitted neutral plates.
The circuit is able to check the efficiency of the plate-patient contact.

Output power timing

1 - 999 ms

Repetition rate of impulses

0 to 250 impulses the second

Neutral electrode

Floating

Dimensions (H x L x D)

150 x 360 x 265 mm

Weight

7.5 Kg

Mains Power

115-230Vac / 50-60Hz.

Duty Cycle

10 s / 30 s

Environmental characteristics of operation


Temperature environment

10C - 40C

Relative humidity

30% - 75%

IT0159GB rev. C

3/5

Atmospheric pressure

70 kPa - 106 kPa

Standard and optional accessories


2/pcs= STANDARD
code
00498.04
00500.L11
00100.05
00100.00
00100.03
00100.04
00100.01
00404.06
00404.01
EQUICAB01
BWA280-030
BWA350-030
BWA350-050
500500.L8
500500.L8/L
500500.L7
500500.L7/L
0210
0210/L
BWA530-134
BWA530-132
BWA530-133
BWA530-017
0230
0230/L
0220
0220/L
500500.L3
500500.L3/L
500500.L4
500500.L4/L
500500.L2
500500.L2/L
500500.L6
500500.L6/L
500500.L10
500500.L10/L
500500.L5
500500.L5/L
500500.L1
500500.L1/L
500500.L9
500500.L9/L
2818C
5046
5365
0350
F7920
00602.100
00602.040
00602.060
00500.00/L
00500.00
00500.03
EQUIKIT01
755VL

IT0159GB rev. C

7= OPTIONAL
description

Electrosurgical unit code


Bipolar adpter
Needles for micro-surgery
Power supply cable 2m 3x1mm GB-IEC
Power supply cable 2m 3x1mm ITALY-IEC
Power supply cable 2m 3x1mm SIEMENS-IEC
Power supply cable 2m 3x1mm USA-IEC
Power supply cable 5m 3x1.5mm SIEMENS-IEC
Cable for connection disposable/5365 neutral plate
Cable for connection steel neutral plate 5046
Cable for equipotential connection
Cable for laparoscopy 3m
Cable for bipolar forceps 3m
Cable for bipolar forceps 5m
Noose electrode (L8) (5pcs) 5 cm
Noose electrode (L8/L) (5pcs) 10 cm
Drop electrode (L7) (5pcs) 5 cm
Drop electrode (L7/L) (5pcs) 10 cm
Disposable blade electrode 7 cm
Disposable blade electrode 15 cm
Lletz electrode 10mm 10cm
Lletz electrode 20mm 10cm
Lletz electrode 20x15mm 10cm
Disposable ball electrode 7 cm
Disposable ball electrode 15 cm
Disposable needlel electrode 7 cm
Disposable needlel electrode 15 cm
Loop electrode E 4mm (L3) (5pcs) 5 cm
Loop electrode E 4mm (L3/L) (5pcs) 10 cm
Loop electrode E 4mm (L3/L) (5pcs) 10 cm
Loop electrode E 8mm (L4) (5pcs) 5 cm
Loop electrode E 8mm (L4/L) (5pcs) 10 cm
Bent thin wire electrode (L2) (5pcs) 5 cm
Bent thin wire electrode (L2/L) (5pcs) 10 cm
Bent thick wire electrode (L6) (5pcs) 5 cm
Bent thick wire electrode (L6/L) (5pcs) 10 cm
Bent ball electrode E 3mm (L10) (5pcs) 5 cm
Bent ball electrode E 3mm (L10/L) (5pcs) 10 cm
Bent hook electrode (L5) (5pcs) 5 cm
Bent hook electrode (L5/L) (5pcs) 10 cm
Straight thin wire electrode (L1) (5pcs) 5 cm
Straight thin wire electrode (L1/L) (5pcs) 10 cm
Straight ball electrode E 3mm (L9) (5pcs) 5 cm
Straight ball electrode E 3mm (L9/L) (5pcs) 10 cm
Conductive rubber neutral electrode
Steel neutral electrode for 00404.01
Steel neutral electrode for 00404.06
Disposable neutral electrode
Disposable split neutral electrode
Fasting bandage 100 cm
Fasting bandage 40 cm
Fasting bandage 60 cm
Kit of assorted electrodes (10pcs) 10cm
Kit of assorted electrodes(10pcs)
Kit of assorted electrodes(6pcs) (L1-2-4-7-9-10) 5cm
Kit for equipotential connection
Disposable handle with finger switches

SURTRON
FLASH 200
10300.40A
2/1
2/5
7
7
7
7
2/1
2/1
7
7
7
7
7
7
7
7
7
2/3
7
7
7
7
7
2/3
7
2/3
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
2/1
2/2
2/2
7
7
7
7
2/1
7
2/1
7

4/5

code
0202/B
00201.00
2835A
BWA435-030
MA159
00300.00
00302.00
00301.03
BWA600-001
BWA600-040
00201.03
F7520

SURTRON
FLASH 200

description
Disposable handle without finger switches
Handle for microsurgical needle
Reusable handle with finger switches
Reusable handle without finger switches
Manual of instructions
Not waterproof foot switch
Waterproof foot switch
Double waterproof foot switch
Curved bipolar forceps 1mm x 195mm
Straight bipolar forceps 1mm x 195mm
Microsurgical handle holder
Electrode cleaning sponge

7
2/1
2/1
7
2/1
7
2/1
7
7
7
7
7

The characteristics and the technical data can be modified without warning.

LED SpA
PROGETTAZIONI E PRODUZIONI ELETTRONICHE
Via Selciatella, 40 I-04010 Aprilia (LT) ITALIA
Tel. +39 06 92870045 Fax +39 06 92870046
www.led.it
e-mail: export@led.it

IT0159GB rev. C

5/5

Vous aimerez peut-être aussi