Vous êtes sur la page 1sur 13

Readme File

GENERAL INFORMATION:
This program computes the ultimate flexural strength of reinforced-concrete (including prestressed) sections externally strengthened with Carbon Fiber Reinforced
Polymer (CFRP) systems manufactured by SIKA Corp. The program also performs serviceability checks and it is applicable to rectangular and T-beams.
The design procedures adopted in this program are in compliance with the American Concrete Institute (ACI) Committee 440 document, "Guide for the
Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures" (ACI 440.2R-02).
TO SUCCESSFULLY IMPLEMENT CFRP DESIGN WITH SPREADSHEET:
1) Load the "SOLVER" tool prior to execution of any calculation or data entry: from the "Tools" menu, choose "Solver", then press "cancel" once
the solver box appears, or choose "OK" if you get this message: "The Active sheet is protected and therefore read only." If the SOLVER
Add-in is not installed on your machine, you will need to do install it first (go to "Tools/Add-Ins" menu and choose "Solver").
2) Go to the appropriate workbook and units (CFRPMetric, CFRPEnglish).
3) Enter all the necessary input information. The input data are entered in the "user input" table (white boxes). They consist of the following:
a) Loading information (flexural demand)
b) Environment information
c) Initial Strains (Yes or No) and condition
d) Concrete substrate surface strength properties
e) Prestress section properties (if applicable)
f) Existing section's properties
g) CFRP system properties and configuration
This information can be input either by directly entering the values/properties in the white cells (by following the "comment cell"
recommendations), or by using the input forms: press the "Enter Data" button, then follow the instructions on the screen. If an error is
made, corrections can be easily implemented by navigating through the form structure. At the end of the data entry, the program will perform
the necessary design calculations, and the results will appear on the screen (all the spreadsheet cells will be updated).
4) Run the design calculations. If the calculations were not completed under the data entry procedure (see the above), then press the "Recalculate"
button. The design calculations should then be automatically performed and all the cells in the spreadsheet will be updated. The easiest way
to check whether or not the calculations are updated and correct is to examine the "equilibrium" cells in the spreadsheet. If they all equal zero,
the calculations are correct; if not, then the spreadsheet calculations did not converge (due to an unreasonable input, for example), or, most
likely, the solver function called by the macro did not execute (most likely because solver was not initially loaded).
5) Observe the results. If a change in the input data is needed, repeat the procedure described in point 3 (or portion thereof).
NOTES:
1) To calculate the distance to the neutral axis (c), the program solves a quadratic or cubic equation. Even though the program
makes the best possible guess in order to estimate the appropriate root, it is possible that a negative or exaggerated
root for c will appear in the table. Therefore, all c values should be checked for possible calculation misinterpretations.
2) When the quadratic equation does not have meaningful roots (for instance when c exceeds h), the program will not be able to
find a viable solution, and it will prompt the user in the appropriate cells. Again, a hand-calculation check is necessary.
3) When the equation for c based on one mathematical model either cannot be solved, or an inappropriate root for c is obtained,
the calculations will not be affected if the state of stress is governed by the other mathematical model (based on the calculated
values for concrete strain). The program will then automatically use the other equation for determining c.

Flexion -ACI 440.2R

CFRP System

USER INPUT
New loading conditions:
MD =
ML =
1.2MD+0.85ML =
0.0
Mu = 1.4MD+1.7ML =
0.0
Environment
Include Initial Condidions?
Initially cracked?
Pulloff ft from test =

Cross Section Properties:


As =
in.2
fy =
ksi
Es =
ksi
f'c =
ksi

k-ft
k-ft
k-ft
k-ft

h=
d=
b=
1 =

ksi

k
ksi

span =
0.8 fy =

No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

0.85
in.
in.
in.
ksi

km =
environm. factor =

Ffs =
Spacing =

f =

0.00
0.015
99
8855
0.000

in.
in.
in.
ksi
ksi
in.2

54
#DIV/0!

ksi
in.

Overall =
creep rupture/fatigue factor

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

Unstrengtened
efe = km fu
c = 0.003
Governing limit state

TS (k)

CC or CCf (k)

Steel rupture?

#DIV/0!
#DIV/0!
#DIV/0!

Unstrength. Check

#DIV/0!

N/A
0.0
#DIV/0!
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0.0
#DIV/0!
0.0
#DIV/0!

Equilibrium
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

TS (k)

Steel Rupture Check: s > r ?

N/A
0.01004
#DIV/0!
#DIV/0!

0.00300
#DIV/0!
0.00300
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

Initial Conditions (DL)

N/A

#DIV/0!

#DIV/0!

Service, Strengthened

#DIV/0!

#DIV/0!

#DIV/0!

#
###
###
#
#
#
#

#DIV/0!
#DIV/0!

###
###
###

#DIV/0!

###

#DIV/0!

OVERALL CHECK
c (in.)
6.84
5.33
5.32
###

#DIV/0!

Rectangular section

Ccw (k)

orf

orf

hc

N/A
0.0
0.0
#DIV/0!

N/A
#DIV/0!
0.77
#DIV/0!

N/A
#DIV/0!
0.40
#DIV/0!

N/A
N/A
N/A
#DIV/0!

N/A
N/A
N/A
#DIV/0!

0.00300
#DIV/0!
0.00300
#DIV/0!

###
###
###
###

#DIV/0!

#DIV/0!

N/A

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

Total CC (k) Ts due to DL

Expected service conditions

NG
Spacing Check: spacing > 0.2L or > 5h?
#DIV/0!

#DIV/0!
Mn (k-ft) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

include
###
###
N

Enter Data
230C w/ Sikadur Hex 330 Epoxy

Pulloff Check: ft from test > 200 psi?

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (k)

Recalculate

STRENGTHENED BEAM CHECK

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Tf (k)

0.90
0.95
0.85
#DIV/0!
0.55

PULLOFF STRENGTH AND


SPACING CHECKS

UNSTRENGTHENED SECTION CHECK


Mni = #DIV/0! k-ft
or W =
#DIV/0!
Mcr = #DIV/0! k-ft

Type
S

VERSION 3.0

REDUCTION FACTORS

CFRP Properties:

in.
in.
in.

hf =
bw =

Prestress?
Bonded ?
Pe =
fpsu =

230C w/ Sikadur Hex 330 Epoxy

Unbonded: fps limit met?

Service
N/A

c (in.)

Tc (k)

Itr (in.4)

ff (ksi)

fs (ksi)

cb

Comment

###

N/A

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

###

N/A

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

Unstngth.
N/A
n_one =
n_two =
conc =

Flexin -ACI 440.2R

USER INPUT
INPUT

CFRP System

New loading conditions:


MD =
ML =
1.2MD+0.85ML =
0
Mu = 1.4MD+1.7ML =
0
Environment
Include Initial Condidions?
Initially cracked?
Pulloff ft from test =

Cross Section Properties:


As =
mm2
fy =
MPa
Es =
MPa
f'c =
MPa

kN-m
kN-m
kN-m

h=
d=
b=
1 =

MPa

mm
mm
mm

kN
Mpa

span =
0.8 fy =

Environmental factor =
f =

No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

km =

CFRP Properties:

0.85

hf =
bw =

Prestress?
Bonded ?
Pe =
fpsu =

REDUCTION FACTORS
FACTORS

S512

ffs =
Spacing =

### kN-m
#DIV/0!
###

kN-m

50
1.2
2660
165000
0

mm2

Pulloff Check: ft from test > 1.38 MPa?

1463
#DIV/0!

MPa
mm

NG
Spacing Check: spacing > 0.2L or > 5h?
#DIV/0!

#DIV/0!
#DIV/0!

Steel rupture?
#DIV/0!

#DIV/0!
#DIV/0!

Governing limit state

N/A
0
###
###

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

0
#DIV/0!
0
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

ANALYSIS OF ELASTIC SECTION


SECTION
LOADING CONDITION

N/A
0.01451
#DIV/0!
#DIV/0!

0.00300
#DIV/0!
0.00300
#DIV/0!

#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!

c (mm) Ccw (kN)


N/A
0
0
#DIV/0!

#DIV/0!
#DIV/0!

###
###

#DIV/0!
#DIV/0!

###
###

orf

orf

hc

N/A
#DIV/0!
0.77
#DIV/0!

N/A
#DIV/0!
0.40
#DIV/0!

N/A
N/A
N/A
#DIV/0!

N/A
N/A
N/A
#DIV/0!

0.00300
#DIV/0!
0.00300
#DIV/0!

#DIV/0!

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Ts due to DL

###
###
###
###
###
###
###

#DIV/0!

OVERALL CHECK
212
137
137
###

###
###
N

Expected s

Steel Rupture Check: s > r ?

include

Enter Data
230C w/ Sikadur Hex 330

PULLOFF STRENGTH AND


SPACING CHECKS

#DIV/0!
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened
efe = km fu
c = 0.003

0.55

Recalculate

STRENGTHENED BEAM CHECK

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium

0.90
0.95
0.85
#DIV/0!

mm
mm
mm
Mpa
MPa

UNSTRENGTHENED SECTION CHECK


Mni =
or W =
Mcr =

Overall =
Creep rupture/fatigue factor

Type
S

VERSION 3.0

Service
N/A

Rectangu
u

###
###
###
###
Unbonded: fps limit met?
Unstngth.
N/A

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

n_one =
n_two =

Initial Conditions (DL)

N/A

#DIV/0!

#DIV/0!

#DIV/0!

N/A

#DIV/0!

#DIV/0!

###

N/A

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

Service, Strengthened

###

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

###

N/A

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!
conc =

To Convert From
English Units
Force
1 k
Pressure
1 ksi
Length
1 in.
Area
1 in.2
Moment
1 k-ft.

to
equals
equals
equals
equals
equals

Metric Units
4.44822 kN
6.89475 Mpa
25.4 mm
645.16 mm2
1.35582 kN-m

to
equals
equals
equals
equals
equals

English Units
0.22481 k
0.14504 ksi
0.0397 in.
0.00155 in.2
0.73756 k-ft.

To Convert
Force
Pressure
Length
Area
Moment

Metric Units
1 kN
1 Mpa
1 mm
1 mm2
1 kN-m

CFRP Properties

Metric Units
Type
CarboDur S512
CarboDur S812
Carbodur S1012
SikaWrap 103C w/ Sikadur Hex 300 Epoxy
SikaWrap 103C w/ Sikadur Hex 306 Epoxy
SikaWrap 230C w/ Sikadur Hex 330 Epoxy
English Units
Type
CarboDur S512
CarboDur S812
Carbodur S1012
SikaWrap 103C w/ Sikadur Hex 300 Epoxy
SikaWrap 103C w/ Sikadur Hex 306 Epoxy
SikaWrap 230C w/ Sikadur Hex 330 Epoxy

flu (MPa)*
2800
2800
2800
717
668
715

flu (ksi)*
406
406
406
104
97
104

* Based on mean test value minus two standard deviations

Page 6

E (MPa)*
165000
165000
165000
65087
58021
61012

Elongation at break
0.0169
0.0169
0.0169
0.0110
0.0115
0.0117

E (ksi)*
23900
23900
23900
9447
8421
8855

Elongation at break
0.0169
0.0169
0.0169
0.0110
0.0115
0.0117

CFRP Properties

b (mm)
50.00
80.00
100.00
N/A
N/A
N/A

t (mm)
1.200
1.200
1.200
1.016
1.016
0.381

b (in)
1.97
3.15
3.94
N/A
N/A
N/A

t (in)
0.047
0.047
0.047
0.040
0.040
0.015

Page 7

2.3.2 TEXT EXAMPLE


Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 30.0
ML = 50.0
1.2MD+0.85ML =
79
Mu = 1.4MD+1.7ML = 127
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
N
Bonded ?
N
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
1000
mm2
fy =
414
MPa
Es =
199950
Mpa
f'c =
34.5
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

300
270
1000
0.80
300
1000
8.00
331

mm
mm
mm

REDUCTION FACTORS

103C w/ Sikadur Hex 300 Epoxy

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

1
1
300
300
1.0
681
65087
305

mm
mm
mm
Mpa
MPa
mm2

375
1000

MPa
mm

UNSTRENGTHENED SECTION CHECK


Mni =
or W =
Mcr =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

98
kN-m
0.003704
58.2 kN-m

Steel rupture?
Unstrength. Check

Unstrengtened
efe = km fu
c = 0.003
Governing limit state

ANALYSIS OF ELASTIC SECTION

0.90
0.95
0.85
0.90
0.55

f =
Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


137
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Tf (kN) TS (kN) CC or CCf (kN) Equilibrium
N/A
414
414
0.00
187
414
601
0.00
465
414
879
0.00
187
414
601
0.00

VERSION 3.0

N/A
0.00942
0.02346
0.00942

0.00300
0.00129
0.00300
0.00129

0.04293
0.00841
0.02132
0.00841

orf

orf

hc

N/A
0.51
0.77
0.51

N/A
0.36
0.40
0.36

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK


S

N/A

c (mm)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

11

149

N/A

0.000070

0.00005

153

138.2

2351208623

N/A

11

0.00007

Uncracked

Service, Strengthened

20

296

316

0.00101

0.000398

0.00148

58

N/A

430313138

66

296

N/A

Cracked

LOADING CONDITION

Service

Tc (kN)

Tf (kN) TS (kN) Total CC (kN) Equilibrium

OK
OK
OK

OK

OVERALL CHECK
c (mm) Ccw (kN)
18
N/A
34
0
33
0
34
0

OK

Itr (mm4)

ff (MPa)

2.3.4.4. TEE SECTION


Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 77.7
ML = 96.3
1.2MD+0.85ML = 175
Mu = 1.4MD+1.7ML = 272
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
N
Bonded ?
N
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
1282
mm2
fy =
414
MPa
Es =
199950
Mpa
f'c =
27.6
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

495
464
914
0.85
89
254
8.38
331

mm
mm
mm

REDUCTION FACTORS

S512

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

216 kN-m
0.003023
55.1 kN-m

Steel rupture?
Unstrength. Check

mm
mm
mm
Mpa
MPa
mm2

1463
85

MPa
mm

efe = km fu
c = 0.003
Governing limit state

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium


N/A
530
530
0.00
225
530
755
0.00
616
530
1146
0.00
225
530
755
0.00

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


293
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened

N/A
0.00758
0.02074
0.00758

0.00300
0.00124
0.00300
0.00124

0.04484
0.00773
0.02044
0.00773

c (mm) Ccw (kN)


29
N/A
61
0
59
0
61
0

OK
OK
OK
OK

OK

OVERALL CHECK
orf

orf

hc

N/A
0.49
0.77
0.49

N/A
0.35
0.40
0.35

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Equilibrium

0.47
0.95
0.85
0.90
0.55

f =

3
1
1
50
1.2
2660
165000
180

UNSTRENGTHENED SECTION CHECK


Mni =
or W =
Mcr =

VERSION 3.0

Service
N/A

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

179

179

N/A

0.000172

0.00070

92

N/A

1664737597

N/A

140

N/A

Cracked

Service, Strengthened

25

376

400

0.00083

0.000374

0.00147

97

N/A

1856665268

137

293

N/A

Cracked

2.3.4.5 UCSD
Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 0.6
ML = 6.3
1.2MD+0.85ML =
6
Mu = 1.4MD+1.7ML =
12
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
N
Bonded ?
N
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
213
mm2
fy =
414
MPa
Es =
199950
Mpa
f'c =
27.6
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

102
81
480
0.85
102
480
2.03
331

mm
mm
mm

REDUCTION FACTORS

S512

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

6
kN-m
0.005478
2.9 kN-m

Steel rupture?
Unstrength. Check

mm
mm
mm
Mpa
MPa
mm2

1463
240

MPa
mm

efe = km fu
c = 0.003
Governing limit state

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium


N/A
88
88
0.00
150
88
238
0.00
174
88
262
0.00
150
88
238
0.00

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


16
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened

N/A
0.00758
0.00877
0.00758

0.00300
0.00246
0.00300
0.00246

0.02340
0.00553
0.00641
0.00553

c (mm) Ccw (kN)


9
N/A
25
0
26
0
25
0

OK
OK
OK
OK

OK

OVERALL CHECK
orf

orf

hc

N/A
0.73
0.77
0.73

N/A
0.38
0.40
0.38

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Equilibrium

0.47
0.95
0.85
0.90
0.55

f =

2
1
1
50
1.2
2660
165000
120

UNSTRENGTHENED SECTION CHECK


Mni =
or W =
Mcr =

VERSION 3.0

Service
N/A

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

N/A

0.000029

0.00002

52

8.2

43938659

N/A

0.00003

Uncracked

Service, Strengthened

30

56

86

0.00154

0.000579

0.00131

26

N/A

12595333

254

261

N/A

Cracked

2.3.4.1. PRESTRESS
Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 230.0
ML = 185.0
1.2MD+0.85ML = 433
Mu = 1.4MD+1.7ML = 637
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
Y
Bonded ?
Y
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
600
mm2
fy =
1720
MPa
Es =
199950
Mpa
f'c =
34.5
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

800
650
750
0.80
120
200
2.03
1376

mm
mm
mm

REDUCTION FACTORS

S512

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?
Steel rupture?
Unstrength. Check

mm
mm
mm
Mpa
MPa
mm2

1463
200

MPa
mm

efe = km fu
c = 0.003
Governing limit state

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium


N/A
1111
1111
0.00
75
1084
1159
0.00
295
1110
1405
0.00
75
1084
1159
0.00

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


645
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened

N/A
0.00758
0.02976
0.00758

0.00300
0.00115
0.00300
0.00115

0.03403
0.01199
0.03063
0.01199

c (mm) Ccw (kN)


63
N/A
97
0
71
0
97
0

OK
OK
OK
OK

OK

OVERALL CHECK
orf

orf

hc

N/A
0.46
0.77
0.46

N/A
0.35
0.40
0.35

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Ts due to DL

0.47
0.95
0.85
0.90
0.55

f =

1
1
1
50
1.2
2660
165000
60

UNSTRENGTHENED SECTION CHECK


Mni = 625 kN-m
or W =
0.001231
Mcr = 107.4 kN-m

VERSION 3.0

Service
OK

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

723

699

24

N/A

0.000104

0.00603

307

N/A

14530983144

N/A

1206

-0.00012

Prestressed

Service, Strengthened

742

720

24

0.00022

0.000244

0.00619

308

N/A

14617367366

37

1237

0.00010

Prestressed

2.3.4.2. RECT BEAM


Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 422.0
ML = 741.0
1.2MD+0.85ML = 1136
Mu = 1.4MD+1.7ML = 1851
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
N
Bonded ?
Y
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
4415
mm2
fy =
414
MPa
Es =
199950
Mpa
f'c =
27.6
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

1200
1100
450
0.85
1200
450
12.00
331

mm
mm
mm

REDUCTION FACTORS

103C w/ Sikadur Hex 300 Epoxy

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?
Steel rupture?
Unstrength. Check

mm
mm
mm
Mpa
MPa
mm2

375
450

MPa
mm

efe = km fu
c = 0.003
Governing limit state

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium


N/A
1826
1826
0.00
249
1826
2076
0.00
317
1826
2144
0.00
249
1826
2076
0.00

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


1875
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened

N/A
0.00942
0.01200
0.00942

0.00300
0.00246
0.00300
0.00246

0.01321
0.00893
0.01163
0.00893

c (mm) Ccw (kN)


204
N/A
230
0
226
0
230
0

OK
OK
OK
OK

OK

OVERALL CHECK
orf

orf

hc

N/A
0.73
0.77
0.73

N/A
0.38
0.40
0.38

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Equilibrium

0.90
0.95
0.85
0.90
0.55

f =

1
1
400
400
1.0
681
65087
406

UNSTRENGTHENED SECTION CHECK


Mni = 1666 kN-m
or W =
0.008919
Mcr = 418.5 kN-m

VERSION 3.0

Service
N/A

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

428

428

N/A

0.000222

0.00049

345

N/A

26409782593

N/A

97

N/A

Cracked

Service, Strengthened

25

1155

1179

0.00093

0.000606

0.00131

350

N/A

27183247086

61

262

N/A

Cracked

2.3.4.3. SLAB
Anexo E-8

USER INPUT

CFRP System

New loading conditions:


MD = 50.0
ML = 75.0
1.2MD+0.85ML = 124
Mu = 1.4MD+1.7ML = 198
Environment Interior
Include Initial Condidions?
Y
Initially cracked?
N
Pulloff ft from test = 1.39
Prestress?
N
Bonded ?
Y
Pe = 700
fpsu = 1862

kN-m
kN-m
kN-m
kN-m

Existing Beam Properties:


As =
2500
mm2
fy =
414
MPa
Es =
199950
Mpa
f'c =
27.6
Mpa
h=
d=
b=
1 =

MPa

hf =
bw =
kN
Mpa

span =
0.8 fy =

200
175
4000
0.85
200
4000
8.00
331

mm
mm
mm

REDUCTION FACTORS

S512

km =
Environmental factor =

CFRP Properties:
No. of strips/sheets:
No. of Sheet Layers:
Sheet Width:
bf =
tf =
ffU =
Ef =
Af =

mm
mm
m
Mpa

ffs =
Spacing =

Mni >1.2MD+ 0.85ML?


act < 0.75 bal?

158 kN-m
0.003571
92.1 kN-m

Steel rupture?
Unstrength. Check

mm
mm
mm
Mpa
MPa
mm2

1463
1000

MPa
mm

efe = km fu
c = 0.003
Governing limit state

Tf (kN) TS (kN) CC or CCf (kN) Equilibrium


N/A
1034
1034
0.00
300
1034
1334
0.00
898
1034
1932
0.00
300
1034
1334
0.00

ANALYSIS OF ELASTIC SECTION


LOADING CONDITION

Overall =
Creep rupture/fatigue factor

PULLOFF STRENGTH AND


SPACING CHECKS
Pulloff Check: ft from test > 1.38 MPa?
OK
Spacing Check: spacing > 0.2L or > 5h?
OK

STRENGTHENED BEAM CHECK


198
Mn (kN-m) =
Serviceability Check: fs < 0.8 fsy ?
Creep Rupt./Fatigue Check: ffs < Ffs ?

OK
OK
OK
OK

Steel Rupture Check: s > r ?

CALCULATED FORCES, STRAINS, NEUTRAL AXIS, ETC., ULTIMATE LIMIT STATE


Unstrengtened

N/A
0.00758
0.02267
0.00758

0.00300
0.00118
0.00300
0.00118

0.03749
0.00654
0.01996
0.00654

c (mm) Ccw (kN)


13
N/A
25
0
23
0
25
0

OK
OK
OK
OK

OK

OVERALL CHECK
orf

orf

hc

N/A
0.47
0.77
0.47

N/A
0.35
0.40
0.35

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

PRESTRESSED SECTION CONCRETE STRESS CHECK

Tf (kN) TS (kN) Total CC (kN) Equilibrium

0.47
0.95
0.85
0.90
0.55

f =

4
1
400
50
1.2
2660
165000
240

UNSTRENGTHENED SECTION CHECK


Mni =
or W =
Mcr =

VERSION 3.0

Service
N/A

c (mm)

Tc (kN)

Itr (mm4)

ff (MPa)

fs (MPa)

cb

Comment

Initial Conditions (DL)

N/A

26

373

N/A

0.000074

0.00005

102

347.0

2777044754

N/A

11

0.00007

Uncracked

Service, Strengthened

39

725

764

0.00099

0.000404

0.00145

39

N/A

492454890

163

290

N/A

Cracked

Vous aimerez peut-être aussi