Vous êtes sur la page 1sur 15

Slim Concealed Ceiling Unit

FXDQ-NBVE

air conditioning systems

technical data

Slim Concealed Ceiling Unit


FXDQ-NBVE

air conditioning systems

technical data

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

TABLE OF CONTENTS
FXDQ-NBVE

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
3
3

Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cooling capacity tables
Heating capacity tables

.............................................. 5
.............................................. 6

Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 7


Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7
8

Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wiring diagram

8
9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Fan characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

1
mat e i tcn snUE Voy BCSr N o - mo Q Vid D nRlX SFIV

1-1

Specifications
TECHNICAL SPECIFICATIONS

Capacity
Power Input (50Hz)

Power Input (60Hz)

FXDQ50NBVE

FXDQ63NBVE

7.1

Cooling

kW

4.5

5.6

Heating

kW

5.0

6.3

8.0

Cooling

kW

0.160

0.165

0.181

Heating

kW

0.147

0.152

0.168

Cooling

kW

0.182

0.185

0.192

Heating

kW

0.168

0.170

0.179

Casing

Material

Dimensions

Unit

Weight

Unit

Heat Exchanger

Dimensions

Galvanised steel plate


Height

mm

200

200

200

Width

mm

900

900

1,100

Depth

mm

620

620

620

kg

27

28

31

Nr of Rows
Fin Pitch

mm

1.5

1.5

1.5

Face Area

0.176

0.176

0.227

12

12

12

Nr of Stages
Fan

Type

Air Flow Rate

Cooling

Fan

FXDQ40NBVE

Sirocco fan
High high

m/min

10.5

12.5

16.5

High

m/min

9.5

11.0

14.5

Low

m/min

8.5

10.0

13.0

External static
pressure

High

Pa

44

44

44

Standard

Pa

15

15

15

Motor

Output (high)

62

130

130

High high

dBA

34

35

36

High

dBA

32

33

34

Low

dBA

30

31

32

Drive
Cooling

Piping connections

Sound Pressure

Liquid (OD)

Direct drive

Type
Diameter

Gas

Flare connection
mm

6.35

Type

Drain (OD)

6.35

9.52

Flare connection

Diameter

mm

Diameter

mm

12.7

12.7

15.9

VP20 (I.D. 20/O.D. 26)

Sound absorbing insulation

Foamed polyethylene

Air Filter

Removable/washable/Mildew proof

Refrigerant control

Electronic expansion valve

Temperature control

Microprocessor thermostat for cooling and heating

Safety devices

Fuse
Fan motor thermal protector

Standard Accessories Standard Accessories

Operation manual
Installation manual
Drain hose
Sealing pads
Clamps
Washer
Insulation for fitting
Clamp metal
Washer fixing plate
Screws for duct flanges
Air filter
Product Quality Certificate

Notes

Nominal cooling capacities are based on : indoor temperature : 27CDB, 19CWB, outdoor
temperature : 35CDB, equivalent refrigerant piping : 7,5m (horizontal)
Nominal heating capacities are based on : indoor temperature : 20CDB, outdoor temperature : 7CDB,
6CWB, equivalent refrigerant piping : 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
External static pressure is changeable to set by the remote control; this pressure means : high static
pressure - standard static pressure.
The operation sound levels are conversion values in anechoic chamber. In practice, sound levels tend
to be higher than the specified values due to ambient noise or reflection. When the suction place is
changed to bottom suction, sound level will increase

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

1
1-2

Specifications
ELECTRICAL SPECIFICATIONS (50HZ)

Power Supply

FXDQ40NBVE

Name

Voltage range

FXDQ63NBVE

VE

Phase

Current

FXDQ50NBVE

1~

Frequency

Hz

Voltage

Minimum circuit amps (MCA)

1.0

1.0

1.1

Maximum fuse amps (MFA)

15

15

15

Full load amps (FLA)

0.8

0.8

0.9

Minimum

Maximum

Notes

50

50

50

220-240

-10%
+10%
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker

1-3

ELECTRICAL SPECIFICATIONS (60HZ)

Power Supply

FXDQ40NBVE

Name

Voltage range
Notes

FXDQ63NBVE

VE

Phase

Current

FXDQ50NBVE

1~

Frequency

Hz

60

60

60

Voltage

220

220

220

Minimum circuit amps (MCA)

1.1

1.3

1.4

Maximum fuse amps (MFA)

15

15

15

Full load amps (FLA)

0.9

1.0

1.1

Minimum

-10%

Maximum

+10%
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Safety device settings

FXDQ20,25,32PB
FXDQ40,50,63NB
Kit name

FXDQ20PB

FXDQ25PB

FXDQ32PB

PC boad (A1P) fuse

FXDQ40NB

FXDQ50NB

FXDQ63NB

250V 5A
OFF: 250V 5A  5C OFF
ON: 83  15C ON

Fan motor thermal protector

4D060926

Options

FXDQ20,25,32PB
FXDQ40,50,63NB
Individual control systems
FXDQ20PBVE
FXDQ25PBVE
FXDQ32PBVE

Kit name
Wired remote control
Infrared remote
control

FXDQ40NBVE
FXDQ50NBVE

FXDQ63NBVE

BRC1D52
H/P

BRC4C65

C/O

BRC4C66

Simplified remote control

BRC2C51

Remote control for hotel use

BRC3A61

Centralized control system


FXDQ20PBVE
FXDQ25PBVE
FXDQ32PBVE

Kit name

FXDQ40NBVE
FXDQ50NBVE

Central remote control

DCS302CA51

Unified on/off control

DCS301BA51

Schedule timer

DST301BA51

FXDQ63NBVE

Other options
FXDQ20PBVE
FXDQ25PBVE
FXDQ32PBVE

Kit name

FXDQ40NBVE
FXDQ50NBVE

Adapter for wiring

KRP1B56

Wiring adapter for electrical


appendices (1)

KRP2A53

Wiring adapter for electrical


appendices (2)

KRP4A54

Remote sensor

KRCS01-1B

Installation box for adapter


PCB.

KBP1BA101

Electrical box
with earth
terminal

2 blocks

KJB212AA

3 blocks

KJB311AA

Noise filter (for


electromagnetic interface
use only)

DST301BA51

External control adapter for


outdoor unit (must be
installed on indoor units)

DTA104A53

Insulation kit for high


humidity

KDT25N32

KDT25N50

FXDQ63NBVE

KDT25N63

4D060939

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Capacity tables

4-1

Cooling capacity tables

FXDQ40,50,63NB
TC: Total Capacity: kW ; PI: Power Input: kW (Comp. + Outdoor fan motor)

Unit size

Nominal
capacity

40

4.5

50

5.6

63

7.1

Outdoor.
air temp.
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0

14.0WB
20.0DB
TC
SHC
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.0
2.5
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
3.8
3.1
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8
4.8
3.8

16.0WB
23.0DB
TC
SHC
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
3.6
2.8
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
4.5
3.5
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3
5.7
4.3

18.0WB
26.0DB
TC
SHC
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
4.2
3.3
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
5.2
3.9
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8

Indoor air temperature


19.0WB
27.0DB
TC
SHC
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
4.5
3.3
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
5.6
4.0
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9

20.0WB
28.0DB
TC
SHC
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.8
3.2
4.7
3.2
4.7
3.2
4.6
3.2
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
6.0
4.0
5.9
4.0
5.8
4.0
5.7
3.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.6
4.9
7.5
4.8
7.4
4.8
7.2
4.7

22.0WB
30.0DB
TC
SHC
5.4
3.3
5.4
3.3
5.4
3.3
5.4
3.3
5.4
3.3
5.4
3.3
5.4
3.3
5.3
3.3
5.2
3.3
5.2
3.2
5.1
3.2
5.0
3.2
4.9
3.2
4.9
3.1
4.8
3.1
4.7
3.1
6.7
4.2
6.7
4.2
6.7
4.2
6.7
4.2
6.7
4.2
6.7
4.2
6.7
4.2
6.6
4.2
6.5
4.1
6.4
4.1
6.3
4.0
6.2
4.0
6.1
4.0
6.0
3.9
5.9
3.9
5.8
3.9
8.5
5.1
8.5
5.1
8.5
5.1
8.5
5.1
8.5
5.1
8.5
5.1
8.5
5.1
8.4
5.1
8.3
5.0
8.1
5.0
8.0
4.9
7.9
4.9
7.8
4.8
7.7
4.8
7.5
4.7
7.4
4.7

24.0WB
32.0DB
TC
SHC
5.9
3.5
5.8
3.5
5.8
3.5
5.7
3.5
5.6
3.4
5.5
3.4
5.5
3.4
5.4
3.3
5.3
3.3
5.3
3.3
5.2
3.3
5.1
3.2
5.0
3.2
5.0
3.2
4.9
3.1
4.8
3.1
7.4
4.1
7.3
4.1
7.2
4.1
7.1
4.0
7.0
4.0
6.9
4.0
6.8
4.0
6.7
3.9
6.6
3.9
6.6
3.9
6.5
3.8
6.4
3.8
6.3
3.8
6.2
3.7
6.1
3.7
6.0
3.7
9.3
5.7
9.2
5.6
9.1
5.5
9.0
5.4
8.8
5.4
8.7
5.3
8.7
5.3
8.5
5.2
8.4
5.1
8.3
5.1
8.2
5.0
8.1
4.9
7.9
4.9
7.8
4.8
7.7
4.8
7.6
4.7

ED39226A

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Capacity tables

4-2

Heating capacity tables

FXDQ40,50,63NB

Unit Size

Nominal capacity

40

5.0

50

6.3

63

8.0

Outdoor
air temperature
CDB
CWB
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7

16.0
kW
3.0
3.0
3.2
3.4
3.6
3.7
3.8
3.9
4.0
4.2
4.4
4.7
4.9
5.1
5.2
5.4
5.6
5.6
5.6
3.7
3.8
4.1
4.3
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.9
6.2
6.4
6.6
6.8
7.0
7.1
7.1
4.7
4.9
5.1
5.4
5.7
6.0
6.1
6.3
6.5
6.8
7.0
7.5
7.9
8.1
8.4
8.7
8.9
9.0
9.0

18.0
kW
2.9
3.0
3.2
3.4
3.6
3.7
3.8
3.9
4.0
4.2
4.4
4.6
4.9
5.1
5.2
5.3
5.3
5.3
5.3
3.7
3.8
4.0
4.3
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.9
6.2
6.4
6.6
6.7
6.7
6.7
6.7
4.7
4.9
5.1
5.4
5.7
6.0
6.1
6.3
6.5
6.7
7.0
7.4
7.8
8.1
8.4
8.5
8.5
8.5
8.5

Indoor air temperature CDB


20.0
21.0
kW
kW
2.9
2.9
3.0
3.0
3.2
3.2
3.4
3.4
3.6
3.5
3.7
3.7
3.8
3.8
3.9
3.9
4.0
4.0
4.2
4.2
4.4
4.4
4.6
4.6
4.9
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
5.0
4.8
3.7
3.7
3.8
3.8
4.0
4.0
4.3
4.2
4.5
4.5
4.7
4.7
4.8
4.8
4.9
4.9
5.1
5.1
5.3
5.3
5.5
5.5
5.8
5.8
6.2
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
6.3
6.1
4.7
4.7
4.8
4.8
5.1
5.1
5.4
5.4
5.7
5.7
6.0
6.0
6.1
6.1
6.2
6.2
6.4
6.4
6.7
6.7
7.0
7.0
7.4
7.4
7.8
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7
8.0
7.7

22.0
kW
2.9
3.0
3.2
3.4
3.5
3.7
3.8
3.9
4.0
4.2
4.4
4.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
3.7
3.8
4.0
4.2
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.8
5.9
5.9
5.9
5.9
5.9
5.9
5.9
4.7
4.8
5.1
5.4
5.7
6.0
6.1
6.2
6.4
6.7
7.0
7.4
7.5
7.5
7.5
7.5
7.5
7.5
7.5

24.0
kW
2.9
3.0
3.2
3.4
3.5
3.7
3.8
3.9
4.0
4.2
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
3.7
3.8
4.0
4.2
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
4.7
4.8
5.1
5.4
5.7
5.9
6.1
6.2
6.4
6.7
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
ED39226A

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Dimensional drawing & centre of gravity

5-1

Dimensional drawing

FXDQ-M9

18 - M4 Holes
(All around)

10
20
50

200
180
160
100

3.2

30
33

130
100
90
80

20 or more

300

Indoor air temperature CDB


16.0
18.0
20.0
21.0
22.0
24.0
kW
kW
kW
kW
kW
kW
620
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6 50 or more
1.6
1.6
1.6
1.6
1.7
1.7
1.7
1.7
1.7
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
Ceiling
2.0
2.0 A
1.9
1.9
1.9
1.9
2.0
2.0
2.0
2.0
2.0
2.0
(Service space)
2.1
2.1
2.1
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.3
2.3
2.3
2.3
2.3
2.2
Allow view A
2.5
2.5
2.4 Inspection door
2.4
2.3
2.2
130 2.5
63
2.5
2.5 (Ceiling opening)
2.4
2.3
2.2
20-M5 Holes
(All
around)
2.6
2.6
2.5
2.4
2.3
2.2
2.7
2.7
2.5
2.4
2.3
2.2
2.8
2.7
2.5
2.4
2.3
2.2
280
2.8
2.7
2.5 9 x P100 = 900
2.4
2.3
2.2
150
980
100
2.8330
2.7
2.5
2.4
2.3
2.2
90
1000
80
1.9
1.9
1.9 1020
1.9
1.9
1.9
1.9
1.9
1.9 (In case of back-suction)
1.9
1.9
1.9
2.1
2.1
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.1
2.3
2.3
2.3
2.3
2.3
2.3
Nr 2.4
Part name
Description
NOTES
2.4
2.4
2.4
2.4
2.4
1 Liquid
pipe
connection
port

6.4
Flare
connection
2.5
2.4
2.4
2.4
2.4
2.4
1
In
case
of
back-suction,
mount
chamber
cover
to
bottom
2 Gas
pipe
connection
port

12.7
Flare
connection
2.5
2.5
2.5
2.5
2.5
2.5 side
3 Drain
2.6 pipe connection port 2.6 VP20 (O.D. 26 / I.D.2.6 20)
2.6
2.6
of2.6
the unit.
4 Drain
2.7 hose (Accessory) 2.7 I.D. 25 (Outlet) 2.7
In 2.7
case of bottom-suction,2.7
mount chamber cover to2.7back side
2.8 box
2.8
2.8
2.8
2.8
2.8
5 Control
of3.0
the unit.
3.0
3.0
3.0
3.0
2.8
6 Transmission
wiring connection
3.1 supply connection 3.1
3.1
3.1 of units name plate:
3.0 control box cover. 2.8
2 Location
7 Power
3.3
3.2
3.2
3.1 the air filter at the3.0suction side.
2.8
8 Suspension
bracket
3 Mount
3.4
3.4
3.2
3.1
3.0
2.8
9 Inspection
door
(Select
its
color
(gravity
method)
50%
or
more).
3.5 for drain
3.4
3.2
3.1
3.0
2.8
10 Socket
3.6
3.4
3.2
3.0 air filter (accessory) when
2.8
It 3.1
can not be equipped with
11 Air filter (Accessory)
3.6
3.4
3.2
3.1
2.8
connecting
duct to suction3.0side.
3.6
3.4
3.2
3.1
3.0
2.8

900

20 or more

20 or more

500
(Suspension bolt pitch)

300

50
20
10

550

100
160
180

47
90
100

Adjustable (0~600)

CWB
300 or more
(Service space)
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
300 or less
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
20 - M5 Holes
-13.0
(All around)
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

23

200
170
153
80

12.5
21
57.5

Suspension bolt
4 - M8 ~ M10

25

CDB
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
(All around) 26
- 4.7 hole
-5.0
10 x P100 = 1000
1140-3.0
(Suspension bolt pitch)
0.0
1080 3.0
1060 5.0
6 x P150 = 900
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
9 x P100 = 900
-7.0
980
1000 -5.0
1020
-3.0
(In case of bottom-suction)
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
1100

2.5

620

20

Nominal capacity
300 or more
(Service space of
installation box for
adaptor
PCB)

60

Unit Size

Outdoor
air temperature

50
170

FXDQ63NB

3D045496C
3TW25512-2A

FXDQ40,50NB
620

50 or more

900

20 or more

20 or more

500
(Suspension bolt pitch)

620

300

300 or more
(Service space)

900

20 or more

300 or more
(Service space of
installation box for
adaptor
PCB)

Ceiling
A
(Service space)

300
100
160
180

100
23

30
33

18 - M4 Holes
(All around)

20-M5 Holes
(All around)

50
170

47
90

63

Allow view A
Inspection door
(Ceiling opening)
50
20
10

550
130

90

200
170
153
80

90

880
860
4 x P150 = 600

Adjustable (0~600)

300 or less

Suspension bolt
4 - M8 ~ M10
12.5
21
57.5

60

(All around) 22 - 4.7 hole


8 x P100 = 800
940
(Suspension bolt pitch)

280
330

150
100
90
80

7 x P100 = 700
780
800
820
(In case of back-suction)

10
20
50

200
180
160
100

20 - M5 Holes
(All around)

7 x P100 = 700
780
800
820
(In case of bottom-suction)

130
100
90
80

Nr
1
2
3
4
5
6
7
8
9
10
11

Part name
Liquid pipe connection port
Gas pipe connection port
Drain pipe connection port
Drain hose (Accessory)
Control box
Transmission wiring connection
Power supply connection
Suspension bracket
Inspection door
Socket for drain
Air filter (Accessory)

Description
6.4 Flare connection
12.7 Flare connection
IVP20 (O.D. 26 / I.D. 20)
I.D. 25 (Outlet)

NOTES

2
3

In case of back-suction, mount chamber cover to bottom side


of the unit.
In case of bottom-suction, mount chamber cover to back side
of the unit.
Location of units name plate: control box cover.
Mount the air filter at the suction side.
(Select its color (gravity method) 50% or more).
It can not be equipped with air filter (accessory) when
connecting duct to suction side.
3D045494B

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Dimensional drawing & centre of gravity

5-2

Centre of gravity

FXDQ40,50NB

4D043886J

FXDQ63NB

4D043887H

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Piping diagram

FXDQ20,25,32PB
FXDQ40,50,63NB

Gas side

Liquid side

Electronic expansion
valve

Filter

Filter

Fan

Indoor heat exchanger

4D060927

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Wiring diagram

7-1

Wiring diagram

FXDQ20,25,32PB
FXDQ40,50,63NB

POWER SUPPLY
Note: 3
Input from outside
Note: 1
Transmission wiring central
remote control

Wired remote
control

Control box
A1P
C1
F1U
HAP

Printed circuit board


Capacitor (M1F)
Fuse (F5A, 250V)
Light emitting diode
(service monitor-green)
Magnetic relay (M1P)
Motor (indoor fan)
Motor (drain pump)
Thermal protector (M1F embedded)

KPR
M1F
M1P
Q1M

: Terminal
,

R1T
R2T
R3T
S1L
T1R
V1TR
X1M
X2M
Y1E

Colors:

Thermistor (air)
Thermistor (coil - 1)
Thermistor (coil - 2)
Float switch
Transformer (220V/22V)
Phase control circuit
Terminal block
Terminal block
Electronic expansion valve

BLK:

Black

Z1CZ2C
R1T
SS1
X16A
X18A

ORG:

Noise filter (ferrite core)


Wired remote control
Thermistor (air)
Selector switch (main/sub)
Connector for optional parts
Connector (adapter for wiring)
Connector (wiring adapter for electrical
appendices)

Orange

WHT:

White

YLW:

Yellow

: Connector

BLU:

Blue

PNK:

Pink

: Field wiring

GRY:

Gray

PRP:

Purple

GRN:

Green

RED:

Red
3D060547

NOTES

1
2
3

10

In case of using central remote control, connect it to the unit in accordance with the attached installation manual.
Remote control model varies according to the combination system, confirm enineering materials and catalogs, etc. before connecting.
When connecting the input wires from outside, forced off or on/off control operation can be selected by remote control.
In details, refer to the installation manual attached to the unit.

VRV Systems Indoor Units

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Sound data

8-1

Sound pressure spectrum

3
Octave band sound pressure level dB(0dB=0.0002bar)

FXDQ63NB
Octave band sound pressure level dB(0dB=0.0002bar)

FXDQ50NB

Approximate
threshold hearing
for continuous
noise

Approximate
threshold hearing
for continuous
noise

Octave band center frequency (Hz)

Octave band center frequency (Hz)

4D060949
NOTE

3
4

Scale
Over All (dB):
HH
(B, G, N is already rectified)
A
35.0
C
40.0
Operating conditons:

Power source: 220~240V 50Hz / 220V 60Hz

Cooling: Return air temperature: 27C DB, 19C WB


Outdoor temperature: 35C DB, 24 C WD

Heating: Return air temperature: 20C DB, 15C WB


Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
2m

1m

Duct

Duct Suction

NOTE

L
31.0
38.0

1
2

3
4

Microphone

Scale
Over All (dB):
HH
(B, G, N is already rectified)
A
36.0
C
42.0
Operating conditons:

Power source: 220~240V 50Hz / 220V 60Hz

Cooling: Return air temperature: 27C DB, 19C WB


Outdoor temperature: 35C DB, 24 C WD

Heating: Return air temperature: 20C DB, 15C WB


Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone

Discharge

1,5m

Discharge

Air flow rate


H
33.0
39.0

2m

1m

Duct

Duct Suction

Air flow rate


H
34.0
40.5

L
32.0
39.0

1,5m

4D060950

Microphone

The operation condition is external static pressure 15 Pa. Operation noise differ with
operation and ambient conditions.

The operation condition is external static pressure 15 Pa. Operation noise differ with
operation and ambient conditions.

Octave band sound pressure level dB(0dB=0.0002bar)

FXDQ40NB

Approximate
threshold hearing
for continuous
noise

Octave band center frequency (Hz)

4D060948
NOTE

1
2

3
4

Scale
Over All (dB):
HH
(B, G, N is already rectified)
A
34.0
C
39.0
Operating conditons:

Power source: 220~240V 50Hz / 220V 60Hz

Cooling: Return air temperature: 27C DB, 19C WB


Outdoor temperature: 35C DB, 24 C WD

Heating: Return air temperature: 20C DB, 15C WB


Outdoor temperature: 7C DB, 6C WB
Measuring place: Anechoic chamber
Location of microphone
2m

1m

Duct

Duct Suction

L
30.0
37.0

1,5m

Discharge

Air flow rate


H
32.0
38.0

Microphone

The operation condition is external static pressure 15 Pa. Operation noise differ with
operation and ambient conditions.

VRV Systems Indoor Units

11

Indoor Units SLIM CONCEALED CEILING UNIT FXDQ-NBVE

Fan characteristics

3D046301C

(mmH2O)
7

60

50

30

High
(standard ESP)
nal
xter
of e
mit e Low
er li pressur SP) (high ESP)
p
p
U tic rd E
sta anda
(st

20

10

rnal

Lower limit of exte


static pressure
(standard ESP)

Low
(standard ESP)

(mmH2O)

terna
of ex
r limit re
Lowetic pressu
sta h ESP)
(hig

(Pa)
70

(mmH2O)
7

60

50

20

10

13

14 15 16 17 18
Air flow rate (m3/min)

rnal

xte
of e
mit e
er li ssur
Lowatic preSP)
st igh E
(h

19

(mmH2O)

(mmH2O)

3
2

Low
(high ESP)

Low
(standard ESP)

5
4

High
(standard ESP)

30

(Pa)

(Pa)
11 12

NOTES

external
Lower limit ofre
static pressu )
(standard ESP

10 11 12 13
Air flow rate (m3/min)

14 15 (mmH2O)

NOTES

The remote control can be used to switch between high and


low.

The remote control can be used to switch between high and


low.

The air flow is set to standard before leaving the factory.


It is possible to switch between standard ESP and high ESP via
the remote control.

The air flow is set to standard before leaving the factory.


It is possible to switch between standard ESP and high ESP via
the remote control.

3D046299C

FXDQ40NB

50

40

(mmH2O)
6

Up
sta per lim
(hightic press it of exte
ESP) ure rnal

(Pa)
60

External static pressure

(mmH2O)
6

30

20

10

High
(standard ESP)

al
ern
ext
of e
t
i
r
lim ssu )
per re ESP
Up tatic p dard
s tan
(s

Low
(standard ESP)

(mmH2O)

High
(high ESP)

Low
(high ESP)

(Pa)

al

tern

ex
it of
er lim sure
Low tic presP)
sta h ES
(hig

al
it of extern
Lower limessure
static pr ESP)
rd
da
(stan

9
10 11 12
Air flow rate (m3/min)

13

(mmH2O)

NOTES

12

40

High
(high ESP)

40

High
(high ESP)

(mmH2O)
7

U
s ppe
(sta tatic p r limit
nda res of
rd sure ext
ESP
ern
a
)

Up
sta per li
(hig tic pre mit of
h ES ssur exte
P) e rnal

(Pa)
70

External static pressure

(mmH2O)
7

3D046300C

FXDQ50NB

Up
sta per limit
(hightic pressu of extern
ESP) re
al

FXDQ63NB

External static pressure

The remote control can be used to switch between high and


low.

The air flow is set to standard before leaving the factory.


It is possible to switch between standard ESP and high ESP via
the remote control.

VRV Systems Indoor Units

Daikin Europe N.V. is approved by LRQA for its Quality


Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.

ISO14001 assures an effective environmental


management system in order to help protect human health
and the environment from the potential impact of our
activities, products and services and to assist in
maintaining and improving the quality of the environment.

Daikin units comply with the European regulations that


guarantee the safety of the product.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

VRV products are not within the scope of the Eurovent


certification programme.

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the products and
services presented therein. Specifications are subject to change without
prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage, in the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted by Daikin
Europe N.V..

Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for


the environmont is set in the EMAS and ISO 14001 systems.
Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende

Daikins unique position as a manufacturer of air


conditioning
equipment,
compressors
and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin has
had the intension to become a leader in the provision
of products that have limited impact on the
environment. This challenge demands the eco design
and development of a wide range of products and an
energy management system, resulting in energy
conservation and a reduction of waste.

Vous aimerez peut-être aussi