Vous êtes sur la page 1sur 2

INVERTER UNO-2.

0-I-OUTD

UNO-2.0-I-OUTD

Description
This new product is well suited for most small sized rooftop installations. This rugged outdoor inverter has been designed as a completely sealed unit to
withstand the harshest environmental conditions.

Key Features

Key Benefits

Flat efficiency curves

High efficiency at all output levels

Outdoor enclosure

Suitable for harsh environmental conditions

Wide input range

Suitable for more panel configurations

Natural convection cooling

Trouble free operation

Technical data and types

UNO-2.0-I-OUTD

Input Side
Absolute Maximum DC Input Voltage (Vmax,abs)
Start-up DC Input Voltage (Vstart)
Operating DC Input Voltage Range (Vdcmin...Vdcmax)
Rated DC Input Power (Pdcr)
Number of Independent MPPT
Maximum DC Input Power for each MPPT (PMPPTmax)
MPPT Input DC Voltage Range (VMPPTmin... VMPPTmax) at Pacr
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax)
Maximum Input Short Circuit Current for each MPPT
Number of DC Inputs Pairs for each MPPT
DC Connection Type

520 V
200 V [adj. 120...350 V]
0.7 x Vstart...520 V
2100 W
1
2300 W
Linear Derating From MAX to Null [470VMPPT520V]
200...470 V
12.5 A / 12.5 A
15.0 A
2
Tool Free PV Connector MC4

Input Protection
Reverse Polarity Protection
Input Over Voltage Protection for each MPPT - Varistor

Yes, from limited current source


2

Output Side
AC Grid Connection Type

Single phase

Rated AC Power (Pacr@cos=1)

2000 W

Maximum AC Output Power (Pacmax@cos=1)

2200 W

Rated AC Grid Voltage (Vac,r)


AC Voltage Range
Maximum AC Output Current (Iac,max)
Rated Output Frequency (fr)
Output Frequency Range (fmin...fmax)
Nominal Power Factor (Cosphiac,r)
Total Current Harmonic Distortion
AC Connection Type

230 V
180...264 V (1)
10.5 A
50 Hz
47...53 Hz(2)
> 0.990
< 2%
Screw terminal block, cable gland M25

Output Protection
Anti-Islanding Protection
Maximum AC Overcurrent Protection
Output Overvoltage Protection - Varistor

According to local standard


15.0 A
2 (L - N / L - PE)

Operating Performance
Maximum Efficiency (max)

96.3%

Weighted Efficiency (EURO)

95.1%

Feed In Power Threshold

24.0 W

Stand-by Consumption

< 8.0 W (3)

Communication
Wired Local Monitoring
User Interface

PVI-USB-RS232_485 (opt.)
Graphic display

Environmental
Ambient Temperature Range
Relative Humidity
Noise Emission
Maximum Operating Altitude without Derating

-25...+60C with derating above 50C


0...100% condensing
< 50 dB(A) @ 1m
2000 m

Physical
Environmental Protection Rating
Cooling
Dimension (H x W x D)
Weight
Mounting System

IP 65
Natural
518 mm x 367 mm x 161 mm
<17 kg
Wall bracket

Safety
Isolation Level
Marking
Safety and EMC Standard
Grid Standard

HF Transformer
CE
EN 50178, EN62109-1, EN62109-2, AS/NZS 3100, AS/NZS 60950,
EN 61000-6-2, EN 61000-6-3 EN 61000-3-2, EN 61000-3-3
CEI 0-21(4) VDE 0126-1-1, VDE-AR-N 4105 (5), G83/2, EN 50438 (not for all national appendices),
RD1699, AS 4777 , C10/11, IEC 61727, ABNT NBR 16149, CLC/FprTS 50549

Product Details
Solahart Warranty (6)

5 Years (6)

1. The AC voltage range may vary depending on specific country grid standard. 2. The Frequency range may vary depending on specific country grid standard. 3. Night time consumption<0.6W.
4. Since their applicability dates, limited to plant power 3kW . 5. Limited to plant power 3.68kVA 6. For full details see Solahart Owners Guide and Installation Instructions.
Specifications and designs included in this datasheet are subject to change without notice.

Solahart Australia Tel: 1300 769 475 www.solahart.com.au


Reorder: SHB/PVINV-UNO2.0-I September 2014