Académique Documents
Professionnel Documents
Culture Documents
0-I-OUTD
UNO-2.0-I-OUTD
Description
This new product is well suited for most small sized rooftop installations. This rugged outdoor inverter has been designed as a completely sealed unit to
withstand the harshest environmental conditions.
Key Features
Key Benefits
Outdoor enclosure
UNO-2.0-I-OUTD
Input Side
Absolute Maximum DC Input Voltage (Vmax,abs)
Start-up DC Input Voltage (Vstart)
Operating DC Input Voltage Range (Vdcmin...Vdcmax)
Rated DC Input Power (Pdcr)
Number of Independent MPPT
Maximum DC Input Power for each MPPT (PMPPTmax)
MPPT Input DC Voltage Range (VMPPTmin... VMPPTmax) at Pacr
Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax)
Maximum Input Short Circuit Current for each MPPT
Number of DC Inputs Pairs for each MPPT
DC Connection Type
520 V
200 V [adj. 120...350 V]
0.7 x Vstart...520 V
2100 W
1
2300 W
Linear Derating From MAX to Null [470VMPPT520V]
200...470 V
12.5 A / 12.5 A
15.0 A
2
Tool Free PV Connector MC4
Input Protection
Reverse Polarity Protection
Input Over Voltage Protection for each MPPT - Varistor
Output Side
AC Grid Connection Type
Single phase
2000 W
2200 W
230 V
180...264 V (1)
10.5 A
50 Hz
47...53 Hz(2)
> 0.990
< 2%
Screw terminal block, cable gland M25
Output Protection
Anti-Islanding Protection
Maximum AC Overcurrent Protection
Output Overvoltage Protection - Varistor
Operating Performance
Maximum Efficiency (max)
96.3%
95.1%
24.0 W
Stand-by Consumption
Communication
Wired Local Monitoring
User Interface
PVI-USB-RS232_485 (opt.)
Graphic display
Environmental
Ambient Temperature Range
Relative Humidity
Noise Emission
Maximum Operating Altitude without Derating
Physical
Environmental Protection Rating
Cooling
Dimension (H x W x D)
Weight
Mounting System
IP 65
Natural
518 mm x 367 mm x 161 mm
<17 kg
Wall bracket
Safety
Isolation Level
Marking
Safety and EMC Standard
Grid Standard
HF Transformer
CE
EN 50178, EN62109-1, EN62109-2, AS/NZS 3100, AS/NZS 60950,
EN 61000-6-2, EN 61000-6-3 EN 61000-3-2, EN 61000-3-3
CEI 0-21(4) VDE 0126-1-1, VDE-AR-N 4105 (5), G83/2, EN 50438 (not for all national appendices),
RD1699, AS 4777 , C10/11, IEC 61727, ABNT NBR 16149, CLC/FprTS 50549
Product Details
Solahart Warranty (6)
5 Years (6)
1. The AC voltage range may vary depending on specific country grid standard. 2. The Frequency range may vary depending on specific country grid standard. 3. Night time consumption<0.6W.
4. Since their applicability dates, limited to plant power 3kW . 5. Limited to plant power 3.68kVA 6. For full details see Solahart Owners Guide and Installation Instructions.
Specifications and designs included in this datasheet are subject to change without notice.