Vous êtes sur la page 1sur 68

Use pursuant to applicable agreements

PRELIMINARY

Title page

Alcatel-Lucent
Remote Radio Head 2X60W - 850, 1900 MHz
Maintenance Guide
3MN-01477-0004-REZZA
Issue 0.02 | January 2014

PRELIMINARY

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

PRELIMINARY

PRELIMINARY

Use pursuant to applicable agreements


Legal notice
Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2014 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

About this document


Purpose

............................................................................................................................................................................................. xi
xi

Reason for reissue

........................................................................................................................................................................ xi
xi

Intended audience

....................................................................................................................................................................... xii
xii

Supported systems

...................................................................................................................................................................... xii
xii

How to use this document


Safety information
Prerequisites

PRELIMINARY

Contents

........................................................................................................................................................ xii
xii

...................................................................................................................................................................... xii
xii

.................................................................................................................................................................................. xii
xii

Conventions used

........................................................................................................................................................................ xii
xii

Related information ................................................................................................................................................................... xiii


xiii
Document support

....................................................................................................................................................................... xv
xv

Technical support ......................................................................................................................................................................... xv


xv
How to order .................................................................................................................................................................................. xv
xv
How to comment .......................................................................................................................................................................... xv
xv
1

Safety statements
Overview ...................................................................................................................................................................................... 1-1
1-1
Structure of safety statements ............................................................................................................................................... 1-2
1-2

Preventive maintenance
Overview ...................................................................................................................................................................................... 2-1
2-1
Preventive maintenance activity .......................................................................................................................................... 2-2
2-2
Corrective maintenance
Overview ...................................................................................................................................................................................... 3-1
3-1
Corrective maintenance

......................................................................................................................................................... 3-2
3-2

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
iii
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

PRELIMINARY

Contents
....................................................................................................................................................................................................................................

Introduction
Overview ...................................................................................................................................................................................... 4-1
4-1
RRH 2X60W solution ............................................................................................................................................................. 4-2
4-2

Hardware description
Overview ...................................................................................................................................................................................... 5-1
5-1
RRH 2X60-1900/1900A hardware description .............................................................................................................. 5-2
5-2
RRH 2X60-850 and hardware description

...................................................................................................................... 5-7
5-7

Node B hardware requirements for RRH support


6

...................................................................................................... 5-11
5-11

Power up and power down procedures


Overview ...................................................................................................................................................................................... 6-1
6-1
Powering up an RRH 2X60W .............................................................................................................................................. 6-2
6-2
Powering down an RRH 2X60W ........................................................................................................................................ 6-4
6-4

Preventive maintenance procedures


Overview ...................................................................................................................................................................................... 7-1
7-1
Inspecting connectors .............................................................................................................................................................. 7-2
7-2
Inspecting pole brackets and pole bands .......................................................................................................................... 7-4
7-4

Corrective maintenance procedure


Overview ...................................................................................................................................................................................... 8-1
8-1
Replacing an RRH 2X60W ................................................................................................................................................... 8-2
8-2

Product conformance statements


Overview ..................................................................................................................................................................................... A-1
A-1

PRELIMINARY

European regulatory requirement compliance

.............................................................................................................. A-2
A-2

Americas Region regulatory requirement compliance ............................................................................................... A-4


A-4
Federal Communications Commission ............................................................................................................................ A-5
A-5
Compliances for other regions/countries
Operating conditions

........................................................................................................................ A-7
A-7

.............................................................................................................................................................. A-8
A-8

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
iv
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

....................................................................................................................................................................................................................................

Cable specifications ................................................................................................................................................................ A-9


A-9
Product labeling ..................................................................................................................................................................... A-10
A-10
Index

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
v
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Contents

PRELIMINARY
PRELIMINARY

Contents
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
vi
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Issue 0.02, January 2014, Reason for reissue

.................................................................................................... xi

Issue 0.01, April 2013, Reason for reissue .......................................................................................................... xi

3-1

RRH 2X60W orderable items

PRELIMINARY

List of tables

............................................................................................................................... 3-2

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
vii
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

List of tables
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
viii
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

4-1

Connections between RRH 2X60W and a d2U Node B

............................................................................. 4-2

5-1

RRH 2X60-1900 two antennas bulkhead top view

5-2

RRH 2X60-1900A four antennas bulkhead top view ................................................................................... 5-3

5-3

RRH 2X60-1900/1900A bulkhead bottom view ............................................................................................ 5-4

5-4

RRH 2X60-850 two antennas bulkhead top view

5-5

RRH 2X60-850 bulkhead bottom view

7-1

Pole brackets and pole bands

....................................................................................... 5-2

PRELIMINARY

List of figures

......................................................................................... 5-7

............................................................................................................. 5-8

................................................................................................................................ 7-5

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
ix
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

List of figures
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
x
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

About this document

PRELIMINARY

About this document

Purpose

The purpose of this document is to describe the preventive and corrective procedures
applicable to the following Alcatel-Lucent Remote Radio Head variants:

2X60W, 850 MHz


2X60W, 1900 MHz

2X60W, 1900A MHz

Reason for reissue

The reissue history for issue 0.02 is shown in the following table:
Table 1

Issue 0.02, January 2014, Reason for reissue

Location

Change

Reason for reissue

LR13.3W:FRS 165530 - RRH2x60-1900A (4 antennas) with


9396 digital units

Related information

CR 01145957 + CR 01145972 (old references of documents)

The reissue history for issue 0.01 is shown in the following table:
Table 2

Issue 0.01, April 2013, Reason for reissue

Location

Change

None

First issue as release-independent document (from NN20500-308,


Release: UA08.1), with updated comments.
The decision has been made to split the document NN20500-308
into 2 documents:

- the other one specific to GM customers

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
xi
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

- one specific to AT&T: the present document (3MN-01477-0004REZZA)

PRELIMINARY

About this document


....................................................................................................................................................................................................................................

Intended audience

The audience for this document is Operations and maintenance personnel.


Supported systems

This release-independent document applies to all Alcatel-Lucent W-CDMA system


releases.
How to use this document

No specific recommendation applies regarding the way readers should read this
document.It applies to the AT&T dedicated products and configuration WCDMA with
9396 d2U or d4U OneBTS.
Safety information

For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites

It is recommended that readers become familiar with the following documents:

Alcatel-Lucent Remote Radio Head 2X60W - 850, 1900 MHz for W-CDMA Technical Description, 3MN-01477-0003-DEZZA

Conventions used
Vocabulary conventions

For a list of the terms, see Alcatel-Lucent W-CDMA System - Terminology,


9YZ-04088-0002-TQZZA.
For convenience, the following terms are used in this publication:

RRH 2X60-850, RRH 2X60-1900, RRH 2X60-1900A


RRH 2X60W

RRH

Typographical conventions

PRELIMINARY

The following typographical conventions are used in this document:


Appearance

Description

Italicized text

Emphasized information

graphical user interface text

Text that is displayed in a graphical user


interface or in a hardware label.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
xii
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

....................................................................................................................................................................................................................................

Appearance

Description

Document reference, reference number

Related document that is referenced in the


document

Related information

PRELIMINARY

About this document

For information on subjects related to the content of this document, refer to the
documents listed in the following table:
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
At this location

For more information on

RRH2X60-XX Model Offer


Provisioning Guide,
UMT/PFO/APP/032664

http://support.alcatel-lucent.
com.

RRH2x

Alcatel-Lucent W-CDMA
System - Safety Guide,
9YZ-04088-0007-TQZZA

http://support.alcatel-lucent.
com.

Safety guidelines and the


catalog of hazard statements
that appear in the
Alcatel-Lucent UMTS
customer documents.

RRH Product Engineering


Information ,
UMT/IRC/APP/020716

http://support.alcatel-lucent.
com.

RRH configurations

Alcatel-Lucent Remote Radio


Head 2X60 W - 850, 1900
MHz - Technical Description,
3MN-01477-0003-DEZZA

http://support.alcatel-lucent.
com.

RRH technical description

Alcatel-Lucent Remote Radio


Head 2X60 W - 850,
1900MHz - Hardware
Installation,
3MN-01477-0002-RJZZA

http://support.alcatel-lucent.
com.

RRH installation

Alcatel-Lucent 9396 digital


2U Node B - Technical
Description,
3MN-00514-0005-DEZZA

http://support.alcatel-lucent.
com.

d2U technical description

Alcatel-Lucent 9396 digital


4U Node B - Technical
Description,
3MN-00512-0005-DEZZA

http://support.alcatel-lucent.
com.

d4U technical description

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
xiii
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Refer to this document

PRELIMINARY
PRELIMINARY

About this document


....................................................................................................................................................................................................................................

Refer to this document

At this location

For more information on

Alcatel-Lucent 9396 digital


2U Node B - Hardware
Installation,
3MN-00514-0004-RJZZA

http://support.alcatel-lucent.
com.

d2U hardware installation

Alcatel-Lucent 9396 digital


4U Node B - Hardware
Installation,
3MN-00512-0004-RJZZA

http://support.alcatel-lucent.
com.

d4U hardware installation

Alcatel-Lucent 9396 digital


2U Node B - Installation Test,
3MN-00514-0003-RJZZA

http://support.alcatel-lucent.
com.

d2U installation test

Alcatel-Lucent 9396 digital


4U Node B - Installation Test,
3MN-00512-0003-RJZZA

http://support.alcatel-lucent.
com.

d4U installation test

Alcatel-Lucent 9396 digital


2U Node B - Operations,
Administration, and
Maintenance,
3MN-00514-0006-REZZA

http://support.alcatel-lucent.
com.

d2U operation, administration


and maintenance

Alcatel-Lucent 9396 digital


4U Node B - Operations,
Administration, and
Maintenance,
3MN-00512-0006-REZZA

http://support.alcatel-lucent.
com.

d4U operation, administration


and maintenance

Alcatel-Lucent 9353 Wireless


Management System Fault
Management,
9YZ-04088-0010-ACZZA

http://support.alcatel-lucent.
com.

Fault management

W-CDMA FIMS-UT Main


Maintenance Terminal Online
Help

http://support.alcatel-lucent.
com.

Main maintenance terminal

W-CDMA Remote
Maintenance Tool Online
Help

http://support.alcatel-lucent.
com.

Remote maintenance tool

W-CDMA Local Maintenance


Terminal Online Help

http://support.alcatel-lucent.
com.

Local maintenance terminal

Standard for Installation of


Lightning Protection Systems,
NFPA

http://support.alcatel-lucent.
com.

Installation of lightning
protection systems

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
xiv
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

....................................................................................................................................................................................................................................

Refer to this document

At this location

For more information on

Recommended Practices on
Surge Voltages in Low Voltage
AC Power Circuits, IEEE
C62.41 (Latest Edition)

http://support.alcatel-lucent.
com.

Power

PRELIMINARY

About this document

Document support

For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:

1-888-582-3688 (for the United States)


1-630-224-2485 (for all other countries)

Technical support

For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order

To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment

To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
xv
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

About this document


....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
xvi
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Safety statements
1

Overview
Purpose

This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
Structure of safety statements

1-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
1-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Safety statements

Structure of safety statements

....................................................................................................................................................................................................................................

Structure of safety statements


Overview

This topic describes the components of safety statements that appear in this document.
General structure

Safety statements include the following structural elements:

E
L
MP

CAUTION

Lifting hazard

SA

Lifting this equipment by yourself can result in injury


due to the size and weight of the equipment.

PRELIMINARY

Always use three people or a lifting device to transport


and position this equipment.
[ABC123]

F
G
H

Item

Structure element

Purpose

Safety alert symbol

Indicates the potential for personal injury


(optional)

Safety symbol

Indicates hazard type (optional)

Signal word

Indicates the severity of the hazard

Hazard type

Describes the source of the risk of damage or


injury

Safety message

Consequences if protective measures fail

Avoidance message

Protective measures to take to avoid the hazard

Identifier

The reference ID of the safety statement


(optional)

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
1-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Structure of safety statements

....................................................................................................................................................................................................................................

Signal words

The signal words identify the hazard severity levels as follows:


Signal word

Meaning

DANGER

Indicates an extremely hazardous situation which, if not avoided, will


result in death or serious injury.

WARNING

Indicates a hazardous situation which, if not avoided, could result in


death or serious injury.

CAUTION

Indicates a hazardous situation which, if not avoided, could result in


minor or moderate injury.

NOTICE

Indicates a hazardous situation not related to personal injury.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
1-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Safety statements

PRELIMINARY
PRELIMINARY

Safety statements

Structure of safety statements

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
1-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Preventive maintenance
2

Overview
Purpose

This chapter describes the preventive maintenance activity applicable to the RRH
2X60W.
Contents
Preventive maintenance activity

2-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
2-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Preventive maintenance

Preventive maintenance activity

....................................................................................................................................................................................................................................

Preventive maintenance activity


Preventive maintenance

The preventive maintenance is used to periodically test the items of equipment that do not
directly trigger any alarm at the WMS. However, the execution of preventive maintenance
procedures can trigger alarms at the WMS.
These procedures must be performed according to the following schedules.
It is possible to group some of the procedures, which reduces the intervention time. The
intervention time indicated corresponds to the intervention time for each item of
equipment.
Note: In certain environments, these procedures may be required more frequently:

Systems located in high seismic areas may require anchor bolts and mounting
hardware to be tightened periodically especially for field installed items.
Connectors may require periodic cleaning in dirty and high humidity areas.

Preventive maintenance schedule for RRH 2X60W equipment


Procedure

Periodicity

Test duration
(approx.)

Inspecting connectors (p. 7-2)

Every two years

10 minutes

Inspecting pole brackets and pole bands


(p. 7-4)

Every two years

10 minutes

Preliminary checks before performing preventive maintenance procedures

WARNING
Personal injury hazard

PRELIMINARY

The personnel working on the cabinet must be authorized to work according to the
applicable safety standards

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
2-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Preventive maintenance activity

....................................................................................................................................................................................................................................

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

PRELIMINARY

Preventive maintenance

Description of a preventive maintenance procedure

A preventive maintenance procedure is divided into the following parts:

Title
Main body with following information:
Intervention time
Tools required

Step-by-step actions
One or more figures to help you execute the actions

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
2-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

Preventive maintenance

Preventive maintenance activity

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
2-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Corrective maintenance
3

Overview
Purpose

This chapter describes the corrective maintenance activity applicable to the RRH 2X60W.
Contents
Corrective maintenance

3-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
3-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Corrective maintenance

Corrective maintenance

....................................................................................................................................................................................................................................

Corrective maintenance
Corrective maintenance activity

The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, see Alcatel-Lucent 9353 Wireless Management
System - User Guide, 9YZ-04088-0014-PCZZA.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process consists of two steps:
1. Locating and identifying the faulty RRH 2X60W through alarms at the WMS. See
"Fault management" chapter in Alcatel-Lucent 9353 Wireless Management System User Guide, 9YZ-04088-0014-PCZZA.
2. Replacing the faulty RRH 2X60W following the replacement procedure detailed in
this publication.
RRH 2X60W replacement

In the case of the RRH 2X60W, no separate module replacement exists: the whole RRH
2X60W is to be replaced. The procedure is detailed in Replacing an RRH 2X60W
(p. 8-2).
The following table indicates the orderable item (code) for each module or item to be
replaced from the RRH 2X60W variants.

PRELIMINARY

Table 3-1

RRH 2X60W orderable items

RRH 2X60W
module/item

Orderable item

Provisioning rule

SFP Optical Transceiver


Multi Mode, Dual Fiber

1AB187280063

One SFP per RRH to be installed in


CPRI_PRI.

SFP Optical Transceiver


Single Mode, Single Fiber

1AB194670019

If single-mode: provide one SFP per


RRH to be installed in CPRI_PRI.

SFP Optical Transceiver


Single Mode, Dual Fiber

1AB187280065

One SFP per RRH to be installed in


CPRI_PRI.

Cable alarm connectorized


-15M

849138136

One if external alarm option is required

For optional orderable items, see the following documents:

RRH 2X60-XX Model Offer Provisioning Guide, UMT/PFO/APP/032664

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
3-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Corrective maintenance

....................................................................................................................................................................................................................................

Description of a replacement procedure

A replacement procedure is divided into the following parts:

Title
Main body with the following information:
Intervention time
Tools required
Impact of the procedure, if necessary

PRELIMINARY

Corrective maintenance

Step-by-step actions

One or more figures are provided to help you execute the actions.
Intervention restrictions

There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:

Isolating procedures
Completion of an on-site intervention
Return to service procedure

General personnel safety instructions

The personnel must obey the safety instructions specific to the installation site:

Rules concerning the premises (see instructions posted on site or in the building)
Rules linked to general personnel safety instructions

The personnel working on the cabinet must be authorized to work according to security
standards.
Equipment safety instructions

The external temperature must be comprised between 40C and + 50C.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
3-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

Corrective maintenance

Corrective maintenance

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
3-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Introduction
4

Overview
Purpose

This chapter presents the RRH 2X60W solution.


Contents
RRH 2X60W solution

4-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
4-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Introduction

RRH 2X60W solution

....................................................................................................................................................................................................................................

RRH 2X60W solution


RRH 2X60W overview

The RRH 2X60W is a solution for a remote RF transceiver that can be located far away
(500 m to 20 km) from a main Node B and interface with this main Node B through an
optical fiber.
The RRH 2X60W provides an external optical interface to be connected to the optical
module of the main Node B.
It also provides an external radio interface according to UMTS standards.
The following figure shows the connections between RRHs and a d2U Node B in star
configuration.
For details concerning the configurations of implementation, refer to chapter 3 in the
document: Alcatel-Lucent Remote Radio Head 2X60W - 850, 1900 MHz - Technical
Description, 3MN-01477-0003-DEZZA.

PRELIMINARY

Figure 4-1 Connections between RRH 2X60W and a d2U Node B

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
4-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Hardware description
5

Overview
Purpose

This chapter describes:

The RRH bulkhead hardware


The connectivity
The LED indicators

It also specifies the Node B hardware requirements for RRH support.


Contents
RRH 2X60-1900/1900A hardware description

5-2

RRH 2X60-850 and hardware description

5-7

Node B hardware requirements for RRH support

5-11

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Hardware description

RRH 2X60-1900/1900A hardware description

....................................................................................................................................................................................................................................

RRH 2X60-1900/1900A hardware description


Bulkhead description

The following figure shows the top view of the RRH 2X60-1900 bulkhead:

PRELIMINARY

Figure 5-1 RRH 2X60-1900 two antennas bulkhead top view

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

RRH 2X60-1900/1900A hardware description

....................................................................................................................................................................................................................................

The following figure shows the top view of the RRH 2X60-1900A bulkhead:
Figure 5-2 RRH 2X60-1900A four antennas bulkhead top view

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Hardware description

PRELIMINARY

Hardware description

RRH 2X60-1900/1900A hardware description

....................................................................................................................................................................................................................................

The following figure shows the bottom view of the RRH 2X60-1900/1900A bulkhead:
Figure 5-3 RRH 2X60-1900/1900A bulkhead bottom view

Connector description

PRELIMINARY

This topic gives an overview of the connectors located on the RRH bulkhead.
Interface

Connector

Power

48 V DC

GND

Ground connection

ALD (Antenna Line Device)

Antenna power and control


1 AISG (RS485) connector
8-pin Circular Din female connector
Support of RETA compatible with AISG 2.0.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

RRH 2X60-1900/1900A hardware description

....................................................................................................................................................................................................................................

Interface

Connector

TX1/RX1

Transmit and receive antenna path


7/16 DIN coaxial female connector for the
connection with the antenna

TX2/RX2

Receive diversity antenna path

PRELIMINARY

Hardware description

7/16 DIN coaxial female connector for the


connection with the diversity antenna
ALM1-3, ALM 4-6

External user alarms connector


Six user alarms
Implemented with 2 X 8-pin circular DIN
female connectors .

CPRI _PRI

CPRI optical port


Used to connect the RRH to the Node B or
another RRH
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover)

CPRI_SEC

CPRI optical port


Used to connect the RRH to the Node B
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover

RX3 and RX4

2 Rx ports located on the top of the RRH


2X60-1900A
RX3 and RX4 are not connected in WCDMA
mode of operation, a waterproof cap protects
the unused connectors

MAINT

Local maintenance terminal2 (MAINT) RJ45


connector located on the bottom of the RRH.

Notes:

1.

A reset button is located next to the MAINT port.

LED description (STATUS)

The table below summarizes these states in priority order, from highest (1) to lowest (13).

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-5
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

There is only one green-red-yellow tri-colored LED. The Base Band Unit (BBU) gets the
LED status periodically and reports it to the management system.

PRELIMINARY
PRELIMINARY

Hardware description

RRH 2X60-1900/1900A hardware description

....................................................................................................................................................................................................................................

Note that one states in the table is marked as not applicable (n/a) for the single LED
display (Background download). In these cases no LED setting is assigned and so the
LED setting defaults to the next lower priority active setting.
ID

RTU State

Description

LED
Display

No power Supplied.

No AC or DC power (dead unit).

Off

Initial power On.

RTU is initializing.

Solid Red

External Power Supply


Failure.

AC or DC input power feed is out of range.

Flash Red

Software download.

The unit is downloading software and RF


transmission is off, but is currently
operational.

Flash Yellow

Nonrecoverable Critical
Failure.

A critical hardware failure prevents either the


transmit path or the active receive paths (or all
paths) from functioning.

Solid Red

Recoverable Critical
Failure.

The unit is not currently operational due to


hardware fault, but should recover (e.g.,
Under-Temperature Warm-Up or
Over-Temperature Critical Shutdown.

Flash Red

CPRI_PRI link Failure.

CPRI_PRI link has failed.

Solid Yellow

Non-Critical
Nonrecoverable
Failure.

Non-Critical fault (other than antenna)


detected, fault is not recoverable, transmission
is still on.

Solid Red

Non-Critical
Recoverable Failure.

Non-Critical fault (other than antenna)


detected, fault is recoverable, transmission is
still on.

Flash Red

10

External Antenna
Failure.

An equipped antenna has a VSWR fault.

Flash Red

11

Background Software
Download.

A background software download is in


progress, RF is currently enabled.

n/a

12

Normal Operation.

No critical failures or faults, transmitter is


enabled.

Solid Green

13

Standby.

No critical failures or faults, but the transmitter


is disabled.

Flash Green

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-6
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

RRH 2X60-850 and hardware description

....................................................................................................................................................................................................................................

RRH 2X60-850 and hardware description


Bulkhead description

The following figures show the top view of the RRH 2X60-850 bulkhead:
Figure 5-4 RRH 2X60-850 two antennas bulkhead top view

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-7
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Hardware description

PRELIMINARY

Hardware description

RRH 2X60-850 and hardware description

....................................................................................................................................................................................................................................

The following figure shows the bottom view of the RRH 2X60-850 bulkhead:
Figure 5-5 RRH 2X60-850 bulkhead bottom view

Connector description

PRELIMINARY

This topic gives an overview of the connectors located on the RRH bulkhead.
Interface

Connector

Power

48 V DC

GND

Ground connection

ALD (Antenna Line Device)

Antenna power and control


1 AISG (RS485) connector
8-pin Circular Din female connector
Support of RETA compatible with AISG 2.0.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-8
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

RRH 2X60-850 and hardware description

....................................................................................................................................................................................................................................

Interface

Connector

TX/RX

Transmit and receive antenna path


7/16 DIN coaxial female connector for the
connection with the antenna

ALM1-3, ALM4-6

External user alarms connector

PRELIMINARY

Hardware description

Six user alarms


Implemented with 2 X 8-pin circular DIN
female connectors (same as AISG).
CPRI _PRI

CPRI optical port


Used to connect the RRH to the Node B or
another RRH
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover)

CPRI_SEC

CPRI optical port


Used to connect the RRH to the Node B
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover

AUX Rx

Two AUX ports1 (AUX_RX1, AUX_RX2)


SMA female connector

MAINT

Local maintenance terminal2 (MAINT) RJ45


connector located on the bottom of the RRH
2X60-850.

Notes:

1.

The two AUX SMA ports are used for antenna sharing feature. They can be configured as
RX ports to bypass the Low Noise Amplifier (LNA) and filters inside the RRH. They also
can be configured as TX ports to output received signal of the main RX ports with 25 dB
gain.

2.

A reset button is located next to the MAINT port.

LED description (STATUS)

There is only one green-red-yellow tri-colored LED. The Base Band Unit (BBU) gets the
LED status periodically and reports it to the management system.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-9
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

The table below summarizes these states in priority order, from highest (1) to lowest (13).

PRELIMINARY
PRELIMINARY

Hardware description

RRH 2X60-850 and hardware description

....................................................................................................................................................................................................................................

Note that one states in the table is marked as not applicable (n/a) for the single LED
display (Background download). In these cases no LED setting is assigned and so the
LED setting defaults to the next lower priority active setting.
ID

RTU State

Description

LED
Display

No power Supplied.

No AC or DC power (dead unit).

Off

Initial power On.

RTU is initializing.

Solid Red

External Power Supply


Failure.

AC or DC input power feed is out of range.

Flash Red

Software download.

The unit is downloading software and RF


transmission is off, but is currently
operational.

Flash Yellow

Nonrecoverable Critical
Failure.

A critical hardware failure prevents either the


transmit path or the active receive paths (or all
paths) from functioning.

Solid Red

Recoverable Critical
Failure.

The unit is not currently operational due to


hardware fault, but should recover (e.g.,
Under-Temperature Warm-Up or
Over-Temperature Critical Shutdown.

Flash Red

CPRI_PRI link Failure.

CPRI_PRI link has failed.

Solid Yellow

Non-Critical
Nonrecoverable
Failure.

Non-Critical fault (other than antenna)


detected, fault is not recoverable, transmission
is still on.

Solid Red

Non-Critical
Recoverable Failure.

Non-Critical fault (other than antenna)


detected, fault is recoverable, transmission is
still on.

Flash Red

10

External Antenna
Failure.

An equipped antenna has a VSWR fault.

Flash Red

11

Background Software
Download.

A background software download is in


progress, RF is currently enabled.

n/a

12

Normal Operation.

No critical failures or faults, transmitter is


enabled.

Solid Green

13

Standby.

No critical failures or faults, but the transmitter


is disabled.

Flash Green

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-10
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Node B hardware requirements for RRH support

....................................................................................................................................................................................................................................

Node B hardware requirements for RRH support


Requirement

The following Node Bs are programmed to support RRH.


Parameter
BBU

RRH 2X60 - 850/1900/1900A

PRELIMINARY

Hardware description

9396 d2U or d4U

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
5-11
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY
PRELIMINARY

Hardware description

Node B hardware requirements for RRH support

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
5-12
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

6ower up and power down


P
procedures

Overview
Purpose

This chapter describes how to power up and power down the RRH 2X60W.
Contents
Powering up an RRH 2X60W

6-2

Powering down an RRH 2X60W

6-4

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
6-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Power up and power down procedures

Powering up an RRH 2X60W

....................................................................................................................................................................................................................................

Powering up an RRH 2X60W


Before you begin

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
Procedure

Perform the following procedure to power up an RRH 2X60W.


...................................................................................................................................................................................................

Check that the circuit breaker dedicated to the RRH 2X60W is 15A.
...................................................................................................................................................................................................

Connect the power cable to the DC connector on the RRH 2X60W bulkhead, see Chapter
5, Hardware description
...................................................................................................................................................................................................

Connect the power cable to the power source ( 48 V DC) on the customer site.
...................................................................................................................................................................................................

Switch ON the circuit breaker.


...................................................................................................................................................................................................

Wait for RRH start-up.


...................................................................................................................................................................................................

Check that the status LEDs on the bulkhead display normal operation, see Chapter 5,
Hardware description. If a non-compliance LEDs status occurred then contact the site
coordinator before going on.

PRELIMINARY

...................................................................................................................................................................................................

On the xCCM optical port, check that the Tx and Rx LEDs are green.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
6-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Powering up an RRH 2X60W

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Check with the WMS administrator if there is not unexpected alarms and that the RRH
2X60W is operational.
E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
6-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Power up and power down procedures

PRELIMINARY

Power up and power down procedures

Powering down an RRH 2X60W

....................................................................................................................................................................................................................................

Powering down an RRH 2X60W


Before you begin

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
Procedure

Perform the following procedure to power down an RRH 2X60W.


...................................................................................................................................................................................................

Switch OFF the circuit breaker on the customer power supply plant.
...................................................................................................................................................................................................

Check that the RRH 2X60W is powered off. All LEDs are OFF.
...................................................................................................................................................................................................

Disconnect the power cable dedicated to the RRH from the power source (-48 V DC) on
the customer site.
...................................................................................................................................................................................................

Unscrew the power cable from the RRH DC connector on the RRH 2X60W bulkhead, see
Chapter 5, Hardware description.

PRELIMINARY

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
6-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

7reventive maintenance
P
procedures

Overview
Purpose

This chapter contains the preventive maintenance procedures applicable to the RRH
2X60W.
Contents
Inspecting connectors

7-2

Inspecting pole brackets and pole bands

7-4

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
7-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Preventive maintenance procedures

Inspecting connectors

....................................................................................................................................................................................................................................

Inspecting connectors
Before you begin

Intervention time: 10 minutes


Tools required: adjustable wrench

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work
according to the security standards.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure

Carry out the following procedure to inspect the connector seals on an RRH 2X60W
bulkhead.

PRELIMINARY

...................................................................................................................................................................................................

Check the bulkhead connectors visually, see Chapter 5, Hardware description.


...................................................................................................................................................................................................

Check that connectors are well tightened.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
7-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Inspecting connectors

....................................................................................................................................................................................................................................

Result: If they move, tighten them with the adjustable wrench.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
7-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Preventive maintenance procedures

PRELIMINARY

Preventive maintenance procedures

Inspecting pole brackets and pole bands

....................................................................................................................................................................................................................................

Inspecting pole brackets and pole bands


Before you begin

The RRH can be installed in an outdoor environment using one of the following mounting
kits:

Floor
Wall
Pole (50-152 mm)

Pole (152-380 mm)

Intervention time: 10 minutes


Tools required:

17-mm (11/16") socket with ratchet


14-mm (9/16") open-end wrench

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.

PRELIMINARY

Important! The personnel working on the cabinet must be authorized to work


according to the security standards.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
7-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Inspecting pole brackets and pole bands

....................................................................................................................................................................................................................................

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

PRELIMINARY

Preventive maintenance procedures

Procedure

Carry out the following procedure to check the pole brackets and pole bands of the RRH
2X60W.
...................................................................................................................................................................................................

Perform a visual test:

Check that the pole brackets are well tightened to the wall bracket. If not, go to Step 2
.
Check that the pole bands are well tightened around the pole. If not, go to Step 2.

Figure 7-1 Pole brackets and pole bands

...................................................................................................................................................................................................

Tighten the pole brackets and/or the pole bands.


Note: Use the 17-mm socket to tighten the pole brackets (tightening torque: 32.2
N.m).

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
7-5
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Use the 14-mm open-end wrench to tighten the pole bands.

PRELIMINARY
PRELIMINARY

Preventive maintenance procedures

Inspecting pole brackets and pole bands

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
7-6
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

8 orrective maintenance
C
procedure

Overview
Purpose

This chapter describes the corrective maintenance procedure applicable to the RRH
2X60W.
Contents
Replacing an RRH 2X60W

8-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
8-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Corrective maintenance procedure

Replacing an RRH 2X60W

....................................................................................................................................................................................................................................

Replacing an RRH 2X60W


Before you begin

The replacement procedure described below is based on the following assumptions:

An investigation was performed and it was determined that the unit to replace was
faulty.
The existing unit is locked at the WMS.
To replace the RRH 2X60W main body with another RRH 2X60W, you ordered one
of the following spare parts:
RRH 2X60-850, two antennae pre-integrated cabinet 3JR10601AA
RRH 2X60-1900, two antennae pre-integrated cabinet 3JR10801AA
RRH 2X60-1900A, four antennae pre-integrated cabinet 3JR39501AA
Note: For details, see Table 3-1, RRH 2X60W orderable items (p. 3-2)
Note: The RRH 2X60W remains supplied with the mains power supply.
Note: The RRH 2X60W has an integrated handle that does not detach from the unit
once it is installed.

Intervention time:

30 minutes

PRELIMINARY

Required tools
Tool

Quantity

Description,

7/16 Torque Wrench

Torque value: 25 Nm -1/+2


Nm / 221 lbf.in -8.8/+17.7
lbf.in

T25 TORX security drive

Fiber cleaning kit

Hexagonal Keys

Screwdrivers for slotted heads

Set torx screwdriver

6 mm

While the technician is on site, the local configuration data and TTLNA data fields are
set with the local management terminal. The technician needs to commission the RRH
with RMT. The initialization, reset, boot, software download, occur with the WMS. The
configuration of the RRH 2X60W with the proper parameter settings are also established
through the WMS. Many of the settings, commissioning data, local configuration data,
and parameters might not have to be changed at all with the replacement of a faulty unit
with a new hardware unit.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
8-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Replacing an RRH 2X60W

....................................................................................................................................................................................................................................

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.

PRELIMINARY

Corrective maintenance procedure

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work
according to the security standards.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure

Carry out the following procedure to replace an RRH 2X60W.


...................................................................................................................................................................................................

Preliminary operations:

Shut down the RRH 2X60W, see the procedure Powering down an RRH 2X60W
(p. 6-4).
Remove the solar shield, using the T25 TORX security drive, and store it in a safe
location.
Disconnect all external cables from the bulkhead.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
8-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Remove the two RF lightning protectors from the 7/16 female RF connectors (on top
of the main body) and store them in a safe location.

PRELIMINARY

Corrective maintenance procedure

Replacing an RRH 2X60W

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Remove the defective RRH 2X60W:

Unscrew the four bolts from the mounting bracket.

Remove the RRH 2X60W from the mounting bracket.

...................................................................................................................................................................................................

Before sending the defective RRH 2X60W to the Repair Center, store the solar shield and
the RF lightning protectors, since these items will be reused for installation of the new
RRH 2X60W.
Note: Only the main body of the defective RRH 2X60W is to be sent to the Repair
Center.
...................................................................................................................................................................................................

Keep the existing cables and protect the connectors with caps near to the existing RRH to
be re-used if necessary.
...................................................................................................................................................................................................

Reinsert the new RRH 2X60W:

Insert the two RF lightning protectors on the 7/16 female RF connectors (on top of the
main body).

Hang the new RRH 2X60W on the mounting bracket.


Screw the four M10 bolts to the mounting bracket.
Connect all external cables to the RRH 2X60W.
Refer to chapter 6 in the document: Alcatel-Lucent Remote Radio Head 2X60 W 850, 1900MHz - Hardware Installation, 3MN-01477-0002-RJZZA
Install the solar shield using the T25 TORX security drive.

...................................................................................................................................................................................................

Switch on the RRH 2X60, see the procedure Powering up an RRH 2X60W (p. 6-2).
...................................................................................................................................................................................................

Check with the WMS administrator that the RRH 2X60W is operational.

PRELIMINARY

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
8-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

PRELIMINARY

Appendix A: Product
conformance statements

Overview
Purpose

This appendix provides the RRH product conformance statements.


Contents
European regulatory requirement compliance

A-2

Americas Region regulatory requirement compliance

A-4

Federal Communications Commission

A-5

Compliances for other regions/countries

A-7

Operating conditions

A-8

Cable specifications

A-9

Product labeling

A-10

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
A-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Product conformance statements

....................................................................................................................................................................................................................................

European regulatory requirement compliance


Radio and Telecom Terminal Equipment

The RRH falls under the requirements of the Radio and Telecom Terminal Equipment
(R&TTE) European directive 1999/5/EC.
The R&TTE directive covers requirements in the following areas:

PRELIMINARY

European regulatory requirement compliance

Protection of the Health and Safety of users and all other persons, including objectives
with respect to safety requirements contained in the Low Voltage Directive
(73/23/EEC)
Electromagnetic compatibility (EMC) protection requirements contained in Directive
89/336/EEC.
This equipment generates, uses, and can radiate radio frequency energy. If not
installed and used in accordance with the instruction manual, it can interfere with
radio communications. However, there is no guarantee that interferences do not occur
in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on.
The user is encouraged to correct any interference problems. EMC requirements have
been selected to ensure an adequate level of compatibility for apparatus in residential,
commercial, and light industrial environments. Compatibility levels, however, do not
cover extreme cases that can occur in any location, but that have a low probability of
occurrence. In particular, they may not cover cases where a source of interference that
is producing repeated transient or continuous phenomena is permanently present. This
could include, for example, a radar or broadcast site in the near vicinity. In these
cases, it may be necessary to limit the source of interference, and/or apply special
protection to the interfered part.
Note: For operation or maintenance inside Alcatel-Lucent systems, the operator must
always wear the antistatic wrist strap to maintain the integrity of the product.
Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources to avoid interference. The routes and standards used to
demonstrate compliance with these requirements are outlined in the following
paragraphs:
Node B EMC
Compliance with essential EMC requirements was demonstrated using E301489-1
& -23.
Node B radio compliance
Compliance with the requirements of effective use of the radio spectrum was
demonstrated using E301908-1 & -3.
Node B safety
Compliance with essential safety requirements was demonstrated using EN60950.
Node B health protection
Compliance with essential health requirements was demonstrated using E50385.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
A-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

European regulatory requirement compliance

....................................................................................................................................................................................................................................

European Union Environmental Directives (EUED)

The RRH is manufactured according to the following two European Union


Environmental Directives:

Restriction of Hazardous Substances (RoHS), 2002/95/EC


The RoHS directive restricts the use of lead, mercury, cadmium, hexavalent
chromium, poly-brominated biphenyls (PBB) and poly-brominated diphenyl ethers
(PBDE) in electrical and electronic products. This directive applies to all electrical
and electronic products placed on the European Union (EU) and European Economic
Area (EEA) markets after July 1, 2006, with certain exemptions, including an
exemption for lead solder in network infrastructure equipment.
Waste of Electrical and Electronic Equipment (WEEE), 2002/96/EC
The WEEE directive mandates the necessary treatment of such equipment when it
enters end-of-life. It specifically identifies requirements for recycling, reuse, and
disposal.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
A-3
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Product conformance statements

PRELIMINARY
PRELIMINARY

Product conformance statements

Americas Region regulatory requirement compliance

....................................................................................................................................................................................................................................

Americas Region regulatory requirement compliance


United States

The statements that follow are the product conformance statements that apply to the
Alcatel-Lucent Remote Radio Head 2X60W when deployed in the Americas Region.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
A-4
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Federal Communications Commission

....................................................................................................................................................................................................................................

Federal Communications Commission


Federal Communications Commission

Important! Changes or modifications not expressly approved by Alcatel-Lucent, Inc.


could void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:

PRELIMINARY

Product conformance statements

(1) this device may not cause harmful interference, and


(2) this device must accept any interference received, including interference that may
cause undesired operation.
FCC Part 15 Class B

Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna


Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
Consult the dealer or an experienced radio/TV technician for help.

FCC Part 68

FIC

04DU9-1SN.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
A-5
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

This equipment complies with Part 68 of the FCC rules and the requirements adopted by
the ACTA. At the upper-right-hand corner inside the cabinet assembly of this equipment
is a label that contains, among other information, a product identifier in the format of
AAAEQ##TXXXX. If requested, this number must be provided to the telephone
company.

PRELIMINARY

Product conformance statements

Federal Communications Commission

....................................................................................................................................................................................................................................

SOC

6.0N

The T1 network interface on this equipment is hardwired to a punchdown block, which


meets the FCC specifications.
If this equipment causes harm to the telephone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required.
However, if advance notice is not practical, the telephone company will notify the
customer as soon as possible. Also, you will be advised of your right to file a complaint
with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the equipment. If this happens, the telephone
company will provide advance notice in order for you to make necessary modifications to
maintain uninterrupted service.
FCC regulations prohibit the connection of customer-provided equipment to central office
implemented systems. Connection to party lines is subject to tariffs; users should contact
their state public utility commission, public service commission, or corporation
commission for information.
If the equipment is causing harm to the telephone network, the telephone company may
request that you disconnect the equipment until the problem is resolved.
If trouble is experienced with this equipment repair or warranty information may be
obtained by contacting:
Technical Support Services, within the United States: +1 630 224 4762, prompt 2
RF approval

This equipment complies with Part 2, Subpart J - Equipment Authorization Procedures, of


the FCC Rules.
This device complies with Part 22 Public Mobile Services, Subpart H Cellular
Radiotelephone Services.

PRELIMINARY

This equipment complies with Part 24 - Personal Communications Services, Subpart E Broadband PCS.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
A-6
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Compliances for other regions/countries

....................................................................................................................................................................................................................................

Compliances for other regions/countries


Compliances for other regions/countries

It is impossible to list all the applicable approvals/compliances as they depend on the


markets and products concerned.
Note: For more information, contact your local Alcatel-Lucent representative.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
A-7
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Product conformance statements

PRELIMINARY

Product conformance statements

Operating conditions

....................................................................................................................................................................................................................................

Operating conditions
Operating conditions

The product compliance standards mentioned above are based on the following operating
conditions:

Doors must be closed and/or covers must be in place.


External cables must be of the same type as specified by Alcatel-Lucent.
The mechanical and electrical characteristics of the product must not be modified in
any way.

PRELIMINARY

Any changes or modifications made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from responsibility regarding standards
compliance.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
A-8
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Cable specifications

....................................................................................................................................................................................................................................

Cable specifications
Cable specifications

Compliance with these standards was verified using cables as specified by


Alcatel-Lucent. The continued compliance of the product relies upon use of the correct
cabling scheme as well as use of identical type cables as specified by Alcatel-Lucent.
Refer to the installation guides for details on cable specifications.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
A-9
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

Product conformance statements

PRELIMINARY

Product conformance statements

Product labeling

....................................................................................................................................................................................................................................

Product labeling
Product labeling

The product label can be located on the inside or the outside of the product, provided that
the operation and/or maintenance personnel have the information when working on the
product.
Node B labelling for European countries

To indicate compliance with the European R&TTE Directive, the RRH bears the
following label in a visible location:

Manufacturers name
Equipment designation

Nominal voltage and maximum rated current

Labelling for other regions / countries

PRELIMINARY

Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
A-10
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

B bulkhead, 5-2, 5-7


.............................................................
C connectors, 5-2, 5-7

procedure, 7-2
.............................................................
I

inspecting
pole bands, 7-4
pole brackets, 7-4

.............................................................

PRELIMINARY

Index

procedure
connectors, 7-2
.............................................................
R replacement procedure, 3-2

replacing procedure
RRH 2X60W, 8-2
requirement, 5-11
.............................................................
S Safety statements, 1-1, 1-2

M maintenance

preventive, 2-2
.............................................................
O orderable items, 3-2
.............................................................
P pole bands

inspecting, 7-4
pole brackets
inspecting, 7-4
powering down
RRH 2X60W, 6-4

RRH 2X60W, 6-2


preventive
maintenance, 2-2

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
Alcatel-Lucent Proprietary
IN-1
3MN-01477-0004-REZZA
Use pursuant to applicable agreements
Issue 0.02 January 2014

PRELIMINARY

powering up

PRELIMINARY
PRELIMINARY

Index
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X60W
IN-2
Use pursuant to applicable agreements
3MN-01477-0004-REZZA
Issue 0.02 January 2014

Vous aimerez peut-être aussi