Vous êtes sur la page 1sur 2

BERNINI

BE 21

TECHNICAL DATA
Display

TECHNICAL DATA
Terminal

REAR VIEW

SIDE VIEW

203,8 mm

14,5 mm

84 mm

Mains Failure Delay


Mains Restore Delay
Mains Under-voltage(V)
Mains Over-voltage(V)
Warm Up Timing
Cooling Down Timing
Generator Under-Voltage (V)
Generator Over-Voltage (V)
Generator Under-Hz (Hz)
Generator Over-Hz (Hz)
Current Transformer Size (A)
Overload Setting (A)
G Failure Alarm (Code)
Glow/Choke Control (Code)
Engine Crank Timing
Engine Running Trigger (V)
Engine Rest Timing
Number of Starting Attempts
Low Oil Pressure By-Pass Delay
Stop Solenoid Timing
Alarm Output Mode or Timing
JC7 Output Control Mode (Code)
Input 1 Control (Mode)
Belt Break Control (Code)
Temperature Switch (n.c/n.o)
ALARM 2 Switch (n.c/n.o)
Automatic Periodic Test (Days)
Automatic Engine Test (Minutes)

105 mm

Ch.0
Ch.1
Ch.2
Ch.3
Ch.4
Ch.5
Ch.6
Ch.7
Ch.8
Ch.9
Ch.10
Ch.11
Ch.12
Ch.13
Ch.14
Ch.15
Ch.16
Ch.17
Ch.18
Ch.19
Ch.20
Ch.21
Ch.22
Ch.23
Ch.24
Ch.25
Ch.26
Ch.27

BE21 provides inexpensive A.M.F


and Generating Set control and monitoring
with digital accuracy.
This microprocessor-based controller
includes 6 push-buttons,
24 LED lamps, 4-digits display,
6 relay outputs, 8 digital inputs,
5 analogue inputs, 28 programmable
parameters, Hour-meter, Digital Calibration,
8 display modes, 14 display-messages
and 4 operating modes.

Parameter

224 mm

Recommended cut-out 190mm x 93mm

35 mm

Description

JA1
JA2
JA3
JA4
JB1
JB2
JB3
JB4
JB5
JB6
JB7
JB8
JB9
JC1
JC2
JC3
JC4
JC5
JC6
JC7
JC8
JC9
JD1
JD2
JD3
JD4
JD5
JD6
JD7
JD8
JD9

+V Battery (Supply)
-v Battery (Supply)
Charge Control Input
Charge Control Input
Generator Voltage Input
Mains Voltage Input
Not Used
Generator Voltage Input
Mains Voltage Input
KG Relay Output (n.o.)
KM Relay Output (n.c.)
KM Relay Output (n.c.)
KG Relay Output (n.o.)
Charger Excitement output
+V Relay Contact Supply
Fuel Solenoid Output
Not Used
Mains Simulation/Test Switch Input
Stop Solenoid Output/Dry Contact
Alarm/Preheat/Choke Relay Output
Stop Solenoid Output/Dry Contact
Start Relay Output
Oil Pressure Contact input
Current Transformer Input
Overload Relay Input
Current Transformer Input
High Temperature Switch Input (note*)
Low Level Fuel Switch Input
Remote Lock Switch Input
Alarm 2 Switch Input (note*)
Alarm 1 Switch input

(note*)

The polarity of the switch is programmable

Specifications

DC supply:
Battery plant 12-24Vdc / 250mA MAX
Mains / Generator Input Voltage Range:
24Vac up to 500Vac
Operating Temperature Range / Humidity:
-30C to +70C /0-95% non condensing
DIN Size / Cut-out:
DIN 192x96 (double size 96x96) / 190 mm x 93 mm
DC Relay Outputs:
4 Amps dc at supply voltage (total current of the Outputs)
AC Relay Outputs:
8 Amps / 250Vac (external 1A Fuses are required)
Shipping Weight / Box Dimensions:
850Gr. / 245 mm x 135 mm x 60 mm

Bernini Design srl


via S. Romano Casetto 26/A 46035 OSTIGLIA (Mn) Italy
tel. ++39 386 31445 fax ++39 386 31657 http://www.bernini-design.com