3) LMS PK has recently got a new customer on-board. The facility has been
acquired and you have been asked to develop layout for fire extinguishers.
What factors will you consider while deciding locations of fire-extinguishers.
The Fire extinguishers should be strategically placed according to
hazards, type of fire, material stored and as recommended in MSDS of
hazardous material nearby. All type of Fire Extinguisher available to
extinguish A,B,C class Fire.
The placement of Fire Extinguisher should be 15 meter reach inside
warehouse if Hydrant system is not available, If Hydrant system is
installed then it should be placed 25 meter reach/400 sq ft area on
prominent locations with easy access.
4) You are part of the compliance audit team. You have been assigned to audit
the PMEs and the maintenance area. List down the points that you will
consider during audit.
Designated PME parking Area
Risk assessment regarding PME
Skilled PME operator with all mandatory qualification including his
OJT record and display their Name list.
Weight capacity of PME, modal, year of manufacturing and
equipment calibration record
Keys should not be available in PME to ignite by anyone
PME Inspection record and maintenance plan
Placement of Fire Extinguisher, Availability of Necessary PPEs and
caution display
Safety precaution for refilling batteries and trained operators with
training record including SOP for batteries Refilling. Housekeeping
and tools placement.
Compressor calibration and placement with respect to associated
hazards at place and SOP document
but has been stopped by security to work as he does not have necessary
PPEs available. How will you deal with this situation? Explain briefly.