Vous êtes sur la page 1sur 26

Radar level measurement

Radar level measurement


Contents

Page

Application examples ........................................ 116


VEGAPULS series 40 ....................................... 117 ff.
VEGAPULS series 50 ....................................... 124 ff.
Dimensions ....................................................... 132 ff.
VEGADIS 50, MINICOM .................................... 140

AL - GB - 115

Radar level measurement

Application examples: Radar level measurement


Continuous measurement with
compact instrument

Profibus PA or
4 20 mA loop powered

Power supply
4 20 mA

HART and
VEGACONNECT

HART and
VEGACONNECT

VVO adjustment
program

VVO adjustment
program

Measuring system with VEGAPULS series 40 or


50K as compact instrument

Measuring system with VEGAPULS series 40 or


50K as compact instrument

A measuring system consists of:

A measuring system consists of:

one VEGAPULS series 40 or 50K


compact instrument two-wire sensor
loop powered with power supply via
4 20 mA, or

Profibus PA sensors VEGAPULS


series 40 or 50P with digital
transmission of measured values

one VEGAPULS series 40 or 50K


compact instrument for use in non-Ex
area with analogue current output

Continuous measurement with


compact instrument in hazardous
areas
Ex area

Ex area

Non-Ex area

Non-Ex area

Ex area

Non-Ex area
Power supply "e"

Profibus PA ia or
4 20 mA ia
loop powered

4 20 mA loop powered

4 20 mA

HART and
VEGACONNECT

HART and
VEGACONNECT

HART and
VEGACONNECT

Zone 0

Measuring system with VEGAPULS series 40 or


50 as compact instrument intrinsically safe

Measuring system with VEGAPULS series 40 or


50 as compact instrument Ex "d"

A measuring system consists of:

A measuring system consists of:

one VEGAPULS 41 45 compact


sensor or 51K 56K two-wire sensor
loop-powered with power supply via
4 20 mA

one VEGAPULS 41 45 compact


instrument or 51K 56K intrinsically
safe ia and suitable separator or

Profibus PA sensors VEGAPULS


41 45 or 51P 56P and a segment
coupler for connection to Profibus DP/
connection to PLC

116 - GB - AL

VVO adjustment
program

VVO adjustment
program

VVO
adjustment
program

one VEGAPULS 41 45 compact


sensor or 51K 56K two-wire sensor
loop-powered in Ex "d" version and
power supply via 4 20 mA

Measuring system with VEGAPULS series 40 or


50 as compact instrument Ex "d" with separate
power supply

A measuring system consists of:


-

one VEGAPULS 41 45 compact


sensor or 51 56 four-wire sensor
with separate power supply in Ex "d"
version and 4 20 mA current output

Radar level measurement

VEGAPULS 41 radar sensors

VEGAPULS 41
Radar sensor for continuous level measurement for very small process
connections and easy applications, 26 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Process connection:
thread PVDF
Antenna system:
horn antenna encapsulated in TFM-PTFE
Process temperature:
-40C +130C
Vessel pressure:
max. 3 bar
Measuring range:
10 m
Protection:
IP 66/IP 67
WE'VE GOT

P R O F

PROCESS FIELD BUS

B U S
ABILITY

Approval
XX without
CX Ex Zone 0, EEx ia IIC T6, ATEX II 1G or 1/2G
DX Ex Zone 0, EEx d ia IIC T6; ATEX II 1/2G
CA Ex Zone 0, EEx ia IIC T6, ATEX IIG or 1/2G; WHG
DA Ex Zone 0, EEx d ia IIC T6, ATEX II 1/2G; WHG
XV FCC
XU FM Division 2 / Zone 2
CU FM Division 1 / Zone 0
DU FM Division 1 / Zone 0, pressure-tight encapsulation
Supply voltage - Output/Signal transmission
B Four-wire 20...72VDC,20...250VAC / 4...20mA HART
D Two-wire-Loop powered / 4...20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection, material, vessel pressure
G G 1A, PVDF thread
N 1 NPT, PVDF thread
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PS41.

Approval "DX", "DA" and "DU": only in conjunction with Housing/Cable entry "D"
Approval "CX", "CA" and "CU": not for supply voltage "B"
Housing/Cable entry "A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Further Profibus accessory see chapter "Accessory"

AL - GB - 117

Radar level measurement

VEGAPULS 42 radar sensors

VEGAPULS 42
Radar sensor for continuous level measurement for small process connections
and difficult vessel geometries (small vessels/installations), 26 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex areas, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Process connection:
thread (material 1.4435, others on request)
Antenna system:
horn antenna (material 1.4435, others on request)
Process temperature:
-40C +150C
Vessel pressure:
max. 40 bar
Measuring range:
10 m
Protection:
IP 66/IP 67

WE'VE GOT

P R O F

PROCESS FIELD BUS

B U S
ABILITY

Approval
XX without
CX PTB Zone 0, EEx ia IIC T6
DX Ex Zone 0, EEx d ia IIC T6 (applied)
CA Ex Zone 0, EEx ia IIC T6, ATEX IIG or 1/2G; WHG
DA Ex Zone 0, EEx d ia IIC T6, ATEX II 1/2G; WHG
XV FCC
XU FM Division 2 / Zone 2
CU FM Division 1 / Zone 0 FCC
DU FM Division 1 / Zone 0, FCC; pressure-tight encapsul.
Supply voltage - Output/Signal transmission
B Four-wire 20...72VDC,20...250VAC / 4...20mA HART
D Two-wire-Loop powered / 4...20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection, material, vessel pressure
G G 1A 1.4435 (also antenna), max.40bar
N 1" NPT 1.4435 (also antenna), max.40bar
Horn antenna, measuring range
A 40mm, max.10m
Seal antenna system, process temperature
V VITON, -25C...+150C
N Viton -40C...+150C
A KALREZ, -15C...+150C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PS42.

Approval "DX", "DA" and "DU": only in conjunction with Housing/Cable entry "D"
Approval "CX", "CA" and "CU": not for supply voltage "B"
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Further Profibus accessory see chapter "Accessory"

118 - GB - AL

Radar level measurement

VEGAPULS 43 radar sensors

VEGAPULS 43
Radar sensor for continuous level measurement of liquids in the chemical,
pharmaceutical and food processing industry, 26 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Process connection:
flange and hygienic fittings
Antenna system:
PTFE coating
Process temperature:
-40C +150C
Vessel pressure:
max. 16 bar
Measuring range:
20 m (see process connection)
Protection:
IP 66/IP 67
WE'VE GOT

P R O F

PROCESS FIELD BUS

ABILITY

B U S

Approval
XX without
CX Ex Zone 0, EEx ia IIC T6, ATEX II 1G or 1/2G
DX Ex Zone 0, EEx d ia IIC T6; ATEX II 1/2G
CA Ex Zone 0, EEx ia IIC T6, ATEX IIG or 1/2G; WHG
DA Ex Zone 0, EEx d ia IIC T6, ATEX II 1/2G; WHG
XV FCC
XU FM Division 2 / Zone 2
CU FM Division 1 / Zone 0
DU FM Division 1 / Zone 0, pressure-tight encapsulation
Supply voltage - Output/Signal transmission
B Four-wire 20...72VDC,20...250VAC / 4...20mA HART
D Two-wire-Loop powered / 4...20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection, measuring range
FA Flange DN50PN40, 10 m
FB Flange DN80PN40, 20 m
FC Flange DN100PN16, 20 m
AA Flange ANSI 2"150 psi, 10 m
AB Flange ANSI 3"150 psi, 20 m
AC Flange ANSI 4"150 psi, 20 m
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PS43.

Approval "DX", "DA" and "DU": only in conjunction with Housing/Cable entry "D"
Approval "CX", "CA" and "CU": not for supply voltage "B"
Further process connections on request
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Further Profibus accessory see chapter "Accessory"

AL - GB - 119

Radar level measurement

VEGAPULS 44 radar sensors

VEGAPULS 44
Radar sensor for continuous level measurement for small process connections
and difficult vessel geometries (small vessel/installations), 26 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Process connection:
flange (material 1.4435, others on request)
Antenna system:
horn antenna (material 1.4435, others on request)
Process temperature:
-40C +150C
Vessel pressure:
max. 40 bar
Measuring range:
20 m (see process connection)
Protection:
IP 66/IP 67
WE'VE GOT

P R O F
PROCESS FIELD BUS

B U S
ABILITY

120 - GB - AL

Radar level measurement

VEGAPULS 44 radar sensors (continuation)

Approval
XX without
CX PTB Zone 0, EEx ia IIC T6
DX Ex Zone 0, EEx d ia IIC T6 (applied)
CA Ex Zone 0, EEx ia IIC T6, ATEX IIG or 1/2G; WHG
DA Ex Zone 0, EEx d ia IIC T6, ATEX II 1/2G; WHG
XV FCC
XU FM Division 2 / Zone 2
CU FM Division 1 / Zone 0 FCC
DU FM Division 1 / Zone 0, FCC; pressure-tight encapsul.
Supply voltage - Output/Signal transmission
B Four-wire 20...72VDC,20...250VAC / 4...20mA HART
D Two-wire-Loop powered / 4...20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Flange, horn antenna, measuring range, material
GCC DN50PN40C, 48mm, max.15m, 1.4435
FCE DN80PN40C, 75mm, max.20m, 1.4435
CCG DN100PN16C, 95mm, max.20m, 1.4435
DCG DN150PN16C, 95mm, max.20m, 1.4435
ARC ANSI 2"150psi RF, 48mm, max.15m, 1.4435
BRE ANSI 3"150psi RF, 75mm, max.20m, 1.4435
CRG ANSI 4"150psi RF, 95mm, max.20m, 1.4435
DRG ANSI 6"150psi RF, 95mm, max.20m, 1.4435
Seal antenna system / Flange temperature
V VITON, -25C...+150C
N Viton -40C...+150C
A KALREZ, -15C...+150C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
Options
X without
J Extension for horn antenna 1.4571
PS44.

Approval "DX", "DA" and "DU": only in conjunction with Housing/Cable entry "D"
Approval "CX", "CA" and "CU": not for supply voltage "B"
Further process connections on request
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Further Profibus accessory see chapter "Accessory"

AL - GB - 121

Radar level measurement

VEGAPULS 45 radar sensors

VEGAPULS 45
Radar sensor for continuous level measurement of liquids with mounted
standpipe ", 26 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Process connection:
flange/thread
Antenna system:
standpipe antenna (material 1.4435, others on request)
Process temperature:
-40C +150C
Vessel pressure:
max. 40 bar
Measuring range:
10 m (over 4 m sectionalized standpipe)
Protection:
IP 66/IP 67
WE'VE GOT

P R O F I
PROCESS FIELD BUS

B U S
ABILITY

122 - GB - AL

Radar level measurement

VEGAPULS 45 radar sensors (continuation)

Approval
XX without
CX PTB Zone 0, EEx ia IIC T6
DX Ex Zone 0, EEx d ia IIC T6 (applied)
CA Ex Zone 0, EEx ia IIC T6, ATEX IIG or 1/2G; WHG
DA Ex Zone 0, EEx d ia IIC T6, ATEX II 1/2G; WHG
XV FCC
XU FM Division 2 / Zone 2
CU FM Division 1 / Zone 0 FCC
DU FM Division 1 / Zone 0, FCC; pressure-tight encapsul.
Supply voltage - Output/Signal transmission
B Four-wire 20...72VDC,20...250VAC / 4...20mA HART
D Two-wire-Loop powered / 4...20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection, material
GB G 1A, 1.4435
NR 1" NPT, 1.4435
AC DN50PN40C, 1.4435
BC DN80PN40C, 1.4435
CC DN100PN16C, 1.4435
DC DN150PN16C, 1.4435
AR ANSI 2"150psi RF, 1.4435
BR ANSI 3"150psi RF, 1.4435
FR ANSI 3"300psi RF, 1.4435
CR ANSI 4"150psi RF, 1.4435
DR ANSI 6"150psi RF, 1.4435
Seal antenna system, process temperature
V VITON, -25C...+150C
N Viton -40C...+150C
A KALREZ, -15C...+150C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PS45.
Standpipe length in mm
per 100 mm

Approval "DX", "DA" and "DU": only in conjunction with Housing/Cable entry "D"
Approval "CX", "CA" and "CU": not for supply voltage "B"
Further process connections on request
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Further Profibus accessory see chapter "Accessory"

AL - GB - 123

Radar level measurement

VEGAPULS 51 radar sensors

VEGAPULS 51
Radar sensor for continuous level measurement of liquids in storage tanks,
6.3 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and/or PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Housing made of plastic PBT or Aluminium (powder-coated)
Process connection:
thread
Antenna system:
rod antenna PP or PPS
Process temperature:
-20C +80C (PP), -20C +120C (PPS)
Measuring range:
20 m
Protection:
IP 66/IP 67
WE'VE GOT

P R O F

PROCESS FIELD BUS

B U S
ABILITY

Instrument version
K Compact instrument with analogue current output
P Digital signal transmission for connect. to Profibus PA
Approval
.X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0
EX0.A Use in Ex-Zone 0, overfill protection WHG
EX.U FM Div.I, CSA Div. I, FCC, Industry Canada
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Supply voltage/Output
D Two-wire-Loop powered / 4-20mA HART
B Four wire 20-72VDC,20-250VAC / 4-20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection/Process pressure
G G 1A PVDF / vessel pressure max.3bar
N 1" NPT PVDF / vessel pressure max.3bar
E G 1A 1.4435 / vessel pressure max.16bar
H 1" NPT 1.4435 / vessel pressure max.16bar
A Clamp 2"/DN50 1.4571 / vessel pressure max.3bar
B Clamp 3"/DN65 1.4571 / vessel pressure max.3bar
J R-socket 2"/DN50 1.4571 / vessel pressure max.3bar
L R-socket DN80 1.4571 / vessel pressure max.3bar
Rod antenna of material
5 PP socket length up to 50mm /process temp.-20C...+80C
3 PPS socket length to 100mm/process temp.-20C...+120C
9 PPS socket length to 250mm/process temp.-20C...+120C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PULS51

Approval "EX0.X", "EX0.A", "EX.U" and supply voltage "B": only in conjunction with Housing/Cable entry "D"
Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm
Housing/Cable entry "A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
External indication VEGADIS 50 see page 140; screwed flanges, mounting accessory and adapter for cable entry and further Profibus accessory see
chapter "Accessory"

124 - GB - AL

Radar level measurement

VEGAPULS 52 radar sensors

VEGAPULS 52
Radar sensor for continuous level measurement of liquids in storage tanks,
6.3 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and/or PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Housing of plastic PBT or Aluminium (powder-coated)
Process connection:
thread
Antenna system:
rod antenna PTFE
Process temperature:
-40C +130C (process connection of PVDF),
-40C +150C (process connection of 1.4571)
Measuring range:
20 m
Protection:
IP 66/IP 67
WE'VE GOT

P R O F

PROCESS FIELD BUS

B U S
ABILITY

Instrument version
K Compact instrument with analogue current output
P Digital signal transmission for connect. to Profibus PA
Approval
.X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0
EX0.A Use in Ex-Zone 0, overfill protection WHG
EX.U FM Div.I, CSA, FCC (US-telecom. approval)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Supply voltage/Output
D Two-wire-Loop powered / 4-20mA HART
B Four wire 20-72VDC,20-250VAC / 4-20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Process connection
G G 1A PVDF/vessel pressure max.3bar/temp.-40...+130C
N 1" NPT PVDF/vessel pressure max.3bar/temp.-40..+130C
E G 1A 1.4571/vessel pres. max.16bar/temp.-40..+150C
H 1" NPT 1.4571/vessel pres. max.16bar/temp.-40..+150C
A C-2"/DN50 1.4571/vessel pressure max. 3 bar
B C-3"/DN65 1.4571/vessel pressure max. 3 bar
J R-socket 2"/DN50 1.4571/vessel pressure max. 3 bar
L R-socket DN80 1.4571/vessel pressure max. 3 bar
Rod antenna of PTFE
5 for socket length up to 50mm
3 for socket length up to 100mm
9 for socket length up to 250mm
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PULS52

Approval "EX0.X", "EX0.A", "EX.U" and supply voltage "B": only in conjunction with Housing/Cable entry "D"
Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm (other lengths on request)
Housing/Cable entry "A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
External indication VEGADIS 50 see page 140; screwed flanges, mounting accessory and adapter for cable entry and further Profibus accessory see
chapter "Accessory"

AL - GB - 125

Radar level measurement

VEGAPULS 53 radar sensors

VEGAPULS 53
Radar sensor for continuous level measurement of liquids in storage tanks,
6.3 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and/or PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Housing of plastic PBT or Aluminium (powder-coated)
Process connection:
flange with PTFE coating
Antenna system:
rod antenna PTFE
Process temperature:
-40C +150C
Vessel pressure:
max. 16 bar
Measuring range:
20 m
Protection:
IP 66/IP 67

WE'VE GOT

P R O F
PROCESS FIELD BUS

B U S
ABILITY

126 - GB - AL

Radar level measurement

VEGAPULS 53 radar sensors (continuation)

Instrument version
K Compact instrument with analogue current output
P Digital signal transmission for connect. to Profibus PA
Approval
.X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0
EX0.A Use in Ex-Zone 0, overfill protection WHG
EX.U FM Div.I, CSA, FCC (US-telecom. approval)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Supply voltage/Output
D Two-wire-Loop powered / 4-20mA HART
B Four wire 20-72VDC,20-250VAC / 4-20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Flange size and antenna system
C Flange DN50PN40C of 1.4571(stst) with PTFE coating
D Flange DN80PN40C of 1.4571(stst) with PTFE coating
G Flange DN100PN16C of 1.4571(stst) with PTFE coating
H Flange DN150PN16C of 1.4571(stst) with PTFE coating
S Flange ANSI 2"150psi of StSt with PTFE-coating
W Flange ANSI 3"150psi of StSt with PTFE-coating
P Flange ANSI 4"150psi of StSt with PTFE-coating
V Flange ANSI 6"150psi of StSt with PTFE-coating
Rod antenna of PTFE
1 for measurement in standpipe, temp. -40C...+150C
3 for socket length up to 100mm, temp. -40C...+150C
9 for socket length up to 250 mm, temp. -40C...+150C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
PULS53

Approval "EX0.X", "EX0.A", "EX.U" and supply voltage "B": only in conjunction with Housing/Cable entry "D"
Further process connections on request
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
External indication VEGADIS 50 see page 140; screwed flanges, mounting accessory and adapter for cable entry and further Profibus accessory see
chapter "Accessory"

AL - GB - 127

Radar level measurement

VEGAPULS 54 radar sensors

VEGAPULS 54
Radar sensor for continuous level measurement of liquids in storage tanks,
6.3 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and/or PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Housing of plastic PBT or Aluminium (powder-coated)
Process connection:
flange (material 1.4571, others on request)
Process temperature:
-40C +150C / -60C +250C (seal antenna system ceramic)
Vessel pressure:
max. 40 bar
Measuring range:
20 m
Protection:
IP 66/IP 67

WE'VE GOT

P R O F
PROCESS FIELD BUS

B U S
ABILITY

128 - GB - AL

Radar level measurement

VEGAPULS 54 radar sensors (continuation)

Instrument version
K Compact instrument with analogue current output
P Digital signal transmission for connect. to Profibus PA
Approval
.X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0
EX0.A Use in Ex-Zone 0, overfill protection WHG
EX0.M Use in Ex-Zone 0, ship approval GL, LR
EX.U FM Div.I, CSA Div. I, FCC, Industry Canada
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Supply voltage/Output
D Two-wire-Loop powered / 4-20mA HART
B Four wire 20-72VDC,20-250VAC / 4-20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Flange size/Antenna diameter/Material
RCX DN50PN40C of 1.4571(stst) without horn antenna
UC6 DN80PN40C and horn antenna 76 of 1.4571(stst)
EC1 DN100PN16C and horn antenna 96 of 1.4571(stst)
FC2 DN150PN16C and horn antenna 146 of 1.4571(stst)
FD2 DN150PN16C(1.4571),PTFE-coat.,enamelled antenna 140
MD4 DN200PN16C(1.4571),PTFE-coat.,enamelled antenna 160
SVX 2"150psiRF of 1.4571 without horn antenna
WV6 3"150psiRF and horn antenna 76 of 1.4571(StSt)
PV1 4"150psiRF and horn antenna 96 of 1.4571(StSt)
VV2 6"150psiRF and horn antenna 146 of 1.4571(StSt)
VD2 6"150psiRF(1.4571),PTFE-coat.,enamelled antenna 140
QD4 8"150psiRF(1.4571),PTFE-coat.,enamelled antenna 160
Seal antenna system / Flange temperature
V VITON, -25C...+150C
A KALREZ, -15C...+150C
P Viton with PTFE-coating, -25C...+200C; max.+10bar
G Graphite with ceramic, -60C...+250C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder coated/M20x1,5
D Alu powder coated EEx d/"NPT
Options
X without
J Extension for horn antenna 1.4571(StSt)
PULS54
Extension for horn antenna

mm (max. 3000 mm); per 100 mm

Approval "EX0.X", "EX0.A", "EX.U" and supply voltage "B": only in conjunction with Housing/Cable entry "D"
Flange size "FD2", "MD4", "VD2" and "QD4": Delivery time more than 10 working days
Further process connections on request
Seal antenna system "V", "A", "G": not possible with antenna material enamel
Housing/Cable entry "A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Option "J": Delivery time more than 10 working days
External indication VEGADIS 50 see page 140; screwed flanges, mounting accessory and adapter for cable entry and further Profibus accessory see
chapter "Accessory"

AL - GB - 129

Radar level measurement

VEGAPULS 56 radar sensors

VEGAPULS 56 high temperature version


Radar sensor for continuous level measurement of liquids at high temperatures,
6.3 GHz technology
Signal processing ECHOFOX for echo analysis with Fuzzy-Logic. Adjustment via
VEGACONNECT and/or PC, detachable adjustment module or HART version via HART
handheld on 4 20 mA.
Signal output:
- Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a
power supply unit.
- Four-wire compact sensor with separate power supply and current output, also for use
in Ex area.
- Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex
area.
Housing of Aluminium (powder-coated)
Process connection:
flange (material 1.4571, others on request)
Process temperature:
-60C +400C
Vessel pressure:
max. 160 bar
Measuring range:
20 m
Protection:
IP 66/IP 67

WE'VE GOT

P R O F
PROCESS FIELD BUS

B U S
ABILITY

130 - GB - AL

Radar level measurement

VEGAPULS 56 radar sensors (continuation)

Instrument version
K Compact instrument with analogue current output
P Digital signal transmission for connect. to Profibus PA
Approval
.X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0
EX0.A Use in Ex-Zone 0, overfill protection WHG
EX0.M Use in Ex-Zone 0, ship approval GL, LR
EX.U FM Div.I, CSA Div.I, FCC, Industry Canada
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Supply voltage/Output
D Two-wire-Loop powered / 4-20mA HART
B Four wire 20-72VDC,20-250VAC / 4-20mA HART
G Profibus PA
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
Flange size/Antenna diameter/Material
RCX DN50PN40C of 1.4571(stst) without horn antenna
UC6 DN80PN40C and horn antenna 76 of 1.4571(stst)
EC1 DN100PN16C and horn antenna 96 of 1.4571(stst)
FC2 DN150PN16C and horn antenna 146 of 1.4571(stst)
SVX 2"150psiRF of 1.4571 without horn antenna
WV6 3"150psiRF and horn antenna 76 of 1.4571(StSt)
PV1 4"150psiRF and horn antenna 96 of 1.4571(StSt)
VV2 6"150psiRF and horn antenna 146 of 1.4571(StSt)
Seal antenna system
G Graphite (coupling of ceramic), temp. -40C...+400C
Housing/Cable entry
K Plastic PBT (Valox)/M20x1,5
N Plastic PBT (Valox)/" NPT
A Alu powder-coated/M20x1,5
D Alu powder coated EEx d/"NPT
Options
X without
J Extension for horn antenna 1.4571(StSt)
PULS56
Extension for horn antenna

mm (max. 3000 mm); per 100 mm

Approval "EX0.X", "EX0.A", "EX.U" and supply voltage "B": only in conjunction with Housing/Cable entry "D"
Further process connections on request
Housing/Cable entry"A": Adapter for cable entry: M20x1.5 on " NPT (stst), article no. 2.22851 see chapter "Accessory"
Option "J": Delivery time more than 10 working days
External indication VEGADIS 50 see page 140; screwed flanges, mounting accessory and adapter for cable entry and further Profibus accessory see
chapter "Accessory"

AL - GB - 131

Radar level measurement

Dimensions

VEGAPULS 41 45
PBT

Aluminium

Aluminium with Exd


terminal compartment

201
165
215

215

185

116

25

205

370
205

322
182

116

185

370

101

10

25

M20x1,5

M20x1,5

135

125

20

142

20

40

139
14

104

219

100

145

24

199

20

40

19

84

130

60,3

20

SW 60

22

SW 60

PBT: 53
Al: 73

" NPT

137

40

48

75

G1 A
1" NPT

VEGAPULS 41

G1 A
1" NPT

VEGAPULS 42
18

18

45

8
1

125

160

165

45

8
1

125

160

165
200

DN 50 PN 40 (C)
ANSI 2" (RF)

DN 80 PN 40 (C)
ANSI 3" (RF)

VEGAPULS 43

132 - GB - AL

200

DN 50 PN 40 (C)
ANSI 2" (RF)

DN 80 PN 40 (C)
ANSI 3" (RF)

VEGAPULS 44

Radar level measurement

65
125

15

1000

22

319

319

29

125

1822

65

20

20

Dimensions

27

45

165285
27

95

22

18

45

L max. 4000

L max. 4000

95
26,9 x 2,6

45

180
240

220

285

DN 100 PN 16 (C)
ANSI 4" (RF)

VEGAPULS 44

DN 150 PN 16 (C)
ANSI 6" (RF)

DN 50DN 150 PN 16/40 (C)


ANSI 2"ANSI 6" (RF)

G1 A
1" NPT

G1 A
1" NPT
with
sectionalized
standpipe

VEGAPULS 45

AL - GB - 133

Radar level measurement

Dimensions
VEGAPULS 51 53
201
165
215
185

10

25

116
25

370

370

205

205

322
182

215
185

116

101

M20x1,5

M20x1,5
125

135

18

80

PBT: 395
Al: 417

PBT: 642 (792)


Al: 665 (815)

PBT: 609 (759)


Al: 632 (782)

PBT: 577
Al: 600

20
2

24

21

" NPT

SW 60

112

36
31

36

25

40

415 (565)

382 (532)

350

35

60

1
8

85

104
125

VEGAPULS 51

VEGAPULS 52

165

DN 50 PN 16 (C)
for standpipe

VEGAPULS 53

134 - GB - AL

Radar level measurement

36

1
8

2
395 (545)

395 (545)

395 (545)

395 (545)

35

22

18

138

158

125

160

180

200

DN 80 PN 40 (C)

45

45

45

104

DN 50 PN 40 (C)

36

35

18

165

PBT: 681 (881)


Al: 704 (854)

PBT: 679 (879)


Al: 702 (852)
36

35

35

22

36

20

PBT: 679 (879)


Al: 702 (852)

PBT: 677 (827)


Al: 700 (850)

80

20

18

Dimensions

220

DN 100 PN 16 (C)

216
240
285

DN 150 PN 16 (C)

VEGAPULS 53

AL - GB - 135

Radar level measurement

Dimensions

VEGAPULS 54
201
165
215
185

10

25

25

205

205

182

116

370

370

101

322

215
185

116

M20x1,5

M20x1,5
135

125

73

PBT

Alu

196

75

20
PBT: 330 (250C: 453)
Al: 373 (250C: 496)

18
23
PBT: 276 (250C: 399)
Al: 319 (250C: 442)

PBT: 535
Al: 583

24
34

PBT: 483
Al : 531

22
30

PBT
V4A

196

Alu

176

PBT

53

53

73

" NPT

144
212

242

76

162
268

22

22

45

45

18

45

125
165
240
285

160
200

295
340

DN 150 PN 16 (C)
136 - GB - AL

DN 200 PN 16 (C)

DN 50 PN 40 (C)

DN 80 PN 40 (C)

Alu
V4A

45

20
PBT: 375 (250C: 498)
Al: 418 (250C: 541)

146

22

240

285

DN 150 PN 16 (C)

45

205

22
PBT: 462 (250C: 585)
Al: 505 (250C: 628)

196

22

295

340

DN 200 PN 16 (C)

30

296

24
PBT: 555 (250C: 678)
Al: 598 (250C: 721)

242

26

355

405

30

DN 250 PN 16 (C)

AL - GB - 137

380

26
PBT: 641 (250C: 764)
Al: 684 (250C: 807)

Radar level measurement

Dimensions

96

18

180
220

DN 100 PN 16 (C)

120

Radar level measurement

Dimensions

VEGAPULS 56
201
165
215
185

10

25

116
25

370

370

205

205

322
182

215
185

116

101

M20x1,5

M20x1,5
125

135

120

76
96

45

45

125
165

DN 50 PN 40 (C)
138 - GB - AL

18

18

8
1

160
200

180
220

DN 80 PN 40 (C)

DN 100 PN 16 (C)

PBT: 642
Al: 665

20

20
PBT: 597
Al: 620
75

18
23
PBT: 543
Al: 566

320

" NPT

Radar level measurement

PBT: 908
Al: 931

26

PBT: 822
Al: 845

24

PBT: 729
Al: 752

380

296

205

22

Dimensions

146

196
242

26

22
22

30

30

45

240
285

295
340

355
405

DN 150 PN 16 (C)
AL - GB - 139

Radar level measurement

Adjustment instruments and accessory for setup of sensors

VEGADIS 50 for VEGASON, VEGAPULS, VEGAFLEX series 50 and VEGAPULS series 40


External indicating instrument without external energy with adjustment possibility by pluggable
adjustment module MINICOM. For surface mounting with LC display for digital and
quasi-analogue indication.
Indication range: -9999 9999, with individually adjustable decimal point
Approval:
CENELEC EEx ia IIC
Protection:
IP 66/IP 67
Weight:
approx. 440 g

Approval
EX.X TV ATEX II 1 G EEx ia IIC T6
Adjustment module MINICOM (pluggable)
X without
B mounted
Indication
X without
A mounted
DIS50
Dimensions see chapter "Indicating instruments"

MINICOM adjustment module


Pluggable adjustment module for adjustment of sensors
VEGASON, VEGAPULS, VEGAFLEX series 50 and VEGAPULS series 40

MINICOM.

140 - GB - AL