Installation Requirements

=========================
- Windows 2000 / Windows XP / Windows Vista
- OMICRON Test Universe 2.11 or higher
For installing the Relay Settings Import Filter application, administrator right
s on the target system are required.

Supported XRIO-Converters
=========================
Filter for AREVA S-R 103 .txt Settings V1.100:
- AREVA P430c ENU V1.100 or higher
- AREVA P430c DEU V1.100 or higher
- AREVA P433 P435 ENU V1.100 or higher
- AREVA P433 P435 DEU V1.100 or higher
- AREVA P631 P632 P633 ENU V1.100 or higher
- AREVA P631 P632 P633 DEU V1.100 or higher
- AREVA PD521 ENU V1.100 or higher
- AREVA PD521 DEU V1.100 or higher
- AREVA PD531 ENU V1.100 or higher
- AREVA PD531 DEU V1.100 or higher
- AREVA PD532 ENU V1.100 or higher
- AREVA PD532 DEU V1.100 or higher
- AREVA PD552 ENU V1.100 or higher
- AREVA PD552 DEU V1.100 or higher
- AREVA PS482 ENU V1.000 or higher
Filter for GE
- GE Multilin
- GE Multilin
- GE Multilin
- GE Multilin

Enervista .csv Settings V1.000:


D60 ENU V1.000 or higher
M60 ENU V1.000 or higher
SR745 ENU V1.002 or higher
T60 ENU V1.001 or higher

Filter for SEL 5010-5030.txt Settings V1.100:


- Schweitzer SEL 311C ENU V1.000 or higher
- Schweitzer SEL 351-7 R401 ENU V1.000 or higher
- Schweitzer SEL 387-0 R608 ENU V1.002 or higher
- Schweitzer SEL 421 R117 ENU V1.000 or higher
- Schweitzer SEL 551 ENU V1.000 or higher
- Schweitzer SEL 587 ENU V1.000 or higher
- Schweitzer SEL 751A ENU V1.000 or higher
Filter for Siemens DIGSI V3 Device .asc Settings V1.000:
- Siemens 7SA510 7SA511 ENU V1.000 or higher
- Siemens 7SA510 7SA511 DEU V1.000 or higher
- Siemens 7SA513 ENU V1.000 or higher
- Siemens 7SJ512 ENU V1.000 or higher
- Siemens 7SJ53 ENU V1.000 or higher
- Siemens 7UT51x ENU V1.000 or higher
Standard Filter for XRIO Files V1.0:
- ABB RED615 V1.1 ENU V1.100 or higher

ABB REF615 V2.0 ENU V1.100 or higher


ABB REL670 V1.1 A32 IEC ENU V1.100 or higher
ABB RET670 V1.1 A30 ENU V1.100 or higher
Siemens 7SA6x ENU V1.000 or higher
Siemens 7SA6X DEU V1.000 or higher
Siemens 7SA522 ENU V1.000 or higher
Siemens 7SD610 ENU V1.000 or higher
Siemens 7SD610 DEU V1.000 oder hher
Siemens 7SJ6x V4.6 ENU V1.000 or higher
Siemens 7SJ6x V4.6 DEU V1.000 or higher
Siemens 7SJ6x V4.7 ENU V1.000 or higher
Siemens 7SJ6x V4.7 DEU V1.000 or higher
Siemens 7SJ6x V4.7 Motor ENU V1.000 or higher
Siemens 7SJ6x V4.7 Motor DEU V1.000 or higher
Siemens 7SK80x ENU V1.000 or higher
Siemens 7SK80x DEU V1.000 or higher
Siemens 7UM62x ENU V1.000 or higher
Siemens 7UM62x DEU V1.000 or higher
Siemens 7UT613 7UT633 ENU V1.000 or higher
Siemens 7UT613 7UT633 DEU V1.000 or higher

Filter for TOSHIBA RSM 100 .csv Settings V1.100:


- TOSHIBA GRZ100 ENU V1.100 or higher
- TOSHIBA GRT100 ENU V1.000 or higher

Other Software Requirements


===========================
ABB:
PCM600 V2.2 or higher is required. The following Connectivity Packages versions
are required:
-for RED615 V1.1: V1.1
-for REF615 V2.0: V2.5
-for REL670 V1.1 A32 IEC: V2.1
-for RET670 V1.1 A30: V2.1
SEL:
5010 Relay Assistant or AcSELerator QuickSet 5030, any version that supports *.t
xt export
GE:
EnerVista UR Setup for T60/D60/M60 XRIO-converters
EnerVista 745 Setup for the SR745 XRIO-converter

Handling
========
The handling of the Relay Settings Import Filter is described in the manual of t
he XRIO-converters listed above.