Vous êtes sur la page 1sur 65

ASC Steel Deck

It is our objective to provide the highest quality


products and services in the steel deck industry. This objective is partially accomplished through conducting extensive
testing programs with independent testing facilities to
ensure that our products comply with the stringent criteria
of todays building codes. Our steel deck products have
been evaluated by the International Conference of Building
Officials (ICC Evaluation Services Report No. 1414), listed
by Underwriters Laboratories, Certified by the Steel Deck
Institute and approved by Factory Mutual and City of Los
Angeles. Additionally, our manufacturing plants are strategically located in the western United States so that we may
provide the best possible service. Most importantly, our
Sales Representatives, Customer Service and Engineering
Services Departments are prepared to assist you with the
specific requirements of your project.

Table of Contents

Floor Deck
B-36 Composite......................................................................2
N-24 Composite ....................................................................8
2W-36 Composite ...............................................................14
2WF-36 Composite .............................................................25
3W-36 Composite ...............................................................30
3WF-36 Composite .............................................................40
ASC2 & ASC3 Composite ....................................................45
Concrete Deck Form

How To Use This Catalog


This Catalog contains information about Floor Deck,
Concrete Form and Deep Deck profiles. Included with the
profiles are reaction tables, section properties, design load
tables and diagrams of the profiles. The
Technical/Specification section contains further information
applicable to all profiles.
Step 1: Select the type of application (Floor Deck, Form
or Deep Deck).
Step 2: Identify which profile is appropriate for your specific design and select the corresponding page number.
Step 3: Contact ASC Steel Deck 1-800-726-2727.

CF 7/8" ................................................................................51
CF 1 3/8" .............................................................................52
Deep Deck
4 1/2" Deep Deck ...............................................................53
6" Deep Deck ......................................................................53
7 1/2" Deep Deck ...............................................................54
Technical/Specifications
General Notes .....................................................................................55
Fire Resistance Ratings ........................................................................56
Shear Stud Data ...................................................................................57
Concrete Weights and Volumes .........................................................58
Code Approvals ...................................................................................58
General Comments on Extraordinary Conditions .............................59
SDI Edge Form .....................................................................................60
Floor Deck Accessories and Standard Details ...................................61
Composite Floor Deck Specifications ................................................62
Materials and Finishes..........................................................................64
Metric Conversion Chart .....................................................................65

Effective January 2008

Preformed Metal Floor Deck

B-36 Composite Floor Deck


2-3/8

3-5/8

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

22
1.68
0.178
0.180
20
2.04
0.220
0.235
2.70
0.302
0.321
18
16
3.36
0.379
0.407
1. Section Properties are based on minimum 38 ksi steel (Fy)

1-1/2
1-3/4

0.195
0.246
0.336
0.415

Allowable Reactions (plf)

36
4 Welds

B-36 Section Properties

7 Welds

Gauge

1 1/2

Bearing Length
2
2 1/2

3 1/2

22

416
468
520
572
625
677
729
1007
1103
1213
1363 1513
1663 1813
20
700
776
853
929
1005
1082 1158
1495
1617
1739
1897 2088
2280 2472
18
1443
1568
1693
1818 1943
2068 2193
2734
2909
3084
3258 3436
3710 3985
16
2434
2608
2782
2957 3131
3305 3480
4350
4578
4806
5034 5262
5490 5786
1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.
B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 3 1/2 Slab Weight: 23.0 psf
Gauge

22

20

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

230
230
230
1501
1710
301
301
301
1568
1820
301
301
301
1721
2056
300
300
300
1890
2309

184
204
204
1462
1656
267
267
267
1522
1754
267
267
267
1660
1969
266
266
266
1813
2201

163
183
183
1429
1609
239
239
239
1483
1698
239
239
239
1607
1895
238
238
238
1748
2107

145
165
145
1401
1569
196
216
216
1448
1650
215
215
215
1562
1830
215
215
215
1691
2026

130
130
130
1376
1533
176
196
196
1419
1607
196
196
196
1522
1774
195
195
195
1641
1955

117
117
117
1354
1502
159
179
179
1392
1570
179
179
179
1487
1724
178
178
178
1597
1893

105
105
105
1334
1474
138
138
138
1369
1537
143
164
164
1456
1679
163
163
163
1558
1838

96
96
96
1317
1449
117
117
117
1348
1507
131
151
151
1428
1639
151
151
151
1523
1788

87
87
87
1301
1427
100
100
100
1329
1480
114
140
140
1403
1604
140
140
140
1492
1743

80
80
80
1287
1407
87
87
87
1312
1456
99
99
130
1380
1571
109
130
130
1463
1703

70
70
70
1274
1388
75
75
75
1296
1434
86
86
86
1359
1542
95
121
121
1437
1666

61
61
61
1262
1372
66
66
66
1282
1413
75
75
75
1340
1515
83
83
113
1414
1632

54
54
54
1251
1356
58
58
58
1269
1395
66
66
66
1323
1491
73
73
106
1392
1602

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

ASC Steel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4
Gauge

22

20

18

16

1 Hour Fire Rating

Slab Weight: 27.5 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

245
268
268
1659
1868
350
350
350
1726
1978
349
349
349
1879
2214
347
347
347
2048
2467

214
238
238
1620
1814
311
311
311
1680
1912
309
309
309
1818
2127
307
307
307
1971
2359

189
213
213
1587
1767
254
278
278
1641
1856
277
277
277
1765
2053
275
275
275
1906
2265

168
168
168
1559
1727
227
251
251
1606
1808
250
250
250
1720
1988
248
248
248
1849
2184

151
151
151
1534
1691
204
228
228
1577
1765
227
227
227
1680
1931
225
225
225
1799
2113

136
136
136
1512
1660
184
208
208
1550
1728
183
207
207
1645
1882
206
206
206
1755
2051

122
122
122
1492
1632
167
167
167
1527
1695
166
190
190
1614
1837
189
189
189
1716
1995

111
111
111
1475
1607
152
152
152
1506
1665
151
175
175
1586
1797
174
174
174
1681
1946

101
101
101
1459
1585
139
139
139
1487
1638
138
138
162
1561
1762
136
161
161
1650
1901

92
92
92
1445
1565
128
128
128
1470
1614
126
126
126
1538
1729
125
150
150
1621
1861

84
84
84
1432
1546
1147
117
117
1454
1591
116
116
116
1517
1700
115
115
140
1595
1824

77
77
77
1420
1530
108
108
108
1440
1571
107
107
107
1498
1673
106
106
131
1572
1790

71
71
71
1409
1514
100
100
100\
1427
1553
99
99
99
1481
1649
98
98
98
1550
1760

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4 3/4
Gauge

22

20

18

16

2 Hour Fire Rating

Slab Weight: 34.4 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

299
328
328
1895
2105
428
428
428
1963
2215
425
425
425
2116
2451
421
421
421
2285
2704

262
291
291
1857
2051
380
380
380
1917
2149
377
377
377
2055
2364
374
374
374
2208
2595

231
231
231
1824
2004
311
340
340
1878
2093
337
337
337
2002
2290
334
334
334
2143
2502

206
206
206
1796
1964
277
306
306
1843
2045
304
304
304
1957
2225
301
301
301
2086
2421

184
184
184
1771
1928
249
278
278
1813
2002
246
276
276
1917
2168
274
274
274
2036
2350

165
165
165
1749
1897
225
225
225
1787
1965
222
252
252
1882
2119
250
250
250
1992
2288

149
149
149
1729
1869
204
204
204
1764
1931
202
231
231
1851
2074
229
229
229
1953
2232

136
136
136
1712
1844
186
186
186
1743
1902
184
184
213
1823
2034
181
211
211
1918
2183

123
123
123
1696
1822
170
170
170
1724
1875
168
168
168
1798
1999
166
196
196
1886
2138

113
113
113
1682
1802
156
156
156
1707
1851
154
154
154
1775
1966
152
152
182
1858
2098

103
103
103
1669
1783
143
143
143
1691
1828
141
141
141
1754
1937
139
139
170
1832
2061

64
94
94
1657
1767
132
132
132
1677
1808
130
130
130
1735
1910
128
128
128
1808
2027

87
87
87
1646
1751
122
122
122
1664
1790
120
120
120
1718
1886
119
119
119
1787
1996

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 3

Preformed Metal Floor Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 11/16
Gauge

22

20

18

16

3 Hour Fire Rating

Slab Weight: 42.1 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

370
405
405
2192
2401
529
529
329
2259
2511
525
525
525
2412
2748
519
519
519
2581
3001

324
359
324
2153
2347
433
469
469
2213
2446
465
465
465
2351
2661
461
461
461
2505
2892

286
286
286
2121
2300
384
420
420
2174
2390
416
416
416
2299
2586
412
412
412
2439
2798

254
254
254
2092
2260
343
343
378
2140
2341
339
375
375
2253
2521
372
372
372
2382
2717

227
227
227
2067
2224
308
308
308
2110
2298
304
341
341
2213
2465
337
337
337
2332
2647

205
205
205
2045
2193
278
278
278
2083
2261
275
311
311
2178
2415
308
308
308
2288
2584

185
185
185
2026
2165
252
252
252
2060
2228
249
249
286
2147
2370
246
283
283
2249
2529

168
168
168
2008
2141
230
230
230
2039
2198
227
227
227
2119
2331
224
261
261
2214
2479

152
152
152
1992
2118
210
210
210
2020
2171
207
207
207
2094
2295
204
204
241
2183
2434

139
139
139
1978
2098
192
192
192
2003
2147
190
190
190
2071
2263
187
187
224
2154
2394

127
127
127
1965
2080
177
177
177
1987
2125
175
175
175
2050
2233
172
172
172
2128
2357

117
117
117
1953
2063
163
163
163
1973
2104
161
161
161
2031
2206
159
159
159
2105
2323

107
107
107
1943
2047
151
151
151
1960
2086
149
149
149
2014
2182
146
146
146
2083
2293

B-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 3 1/2 Slab Weight: 30.3 psf
Gauge

22

20

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

205
230
230
1825
2035
301
301
301
1893
2144
301
301
301
2046
2381
300
300
300
2215
2634

179
204
204
1787
1980
267
267
267
1847
2079
267
267
267
1984
2294
266
266
266
2138
2525

157
183
157
1754
1934
213
239
239
1807
2023
239
239
239
1932
2219
238
238
238
2072
2432

139
139
139
1725
1893
190
216
216
1773
1974
215
215
215
1886
2155
215
215
215
2015
2351

124
124
124
1700
1858
170
196
196
1743
1932
196
196
196
1847
2098
195
195
195
1965
2280

111
111
111
1678
1826
153
153
153
1717
1894
152
179
179
1811
2048
178
178
178
1921
2217

100
100
100
1659
1799
138
138
138
1693
1861
137
164
164
1780
2004
163
163
163
1882
2162

90
90
90
1641
1774
125
125
125
1672
1831
125
151
151
1752
1964
124
151
151
1847
2112

81
81
81
1626
1751
114
114
114
1653
1804
113
113
140
1727
1928
113
140
140
1816
2068

74
74
74
1611
1731
104
104
104
1636
1780
104
104
104
1704
1896
103
130
130
1787
2027

67
67
67
1599
1713
95
95
95
1621
1758
95
95
95
1684
1866
94
94
121
1762
1990

61
61
61
1587
1696
83
83
83
1606
1738
87
87
87
1665
1840
86
86
113
1738
1957

55
55
55
1576
1681
73
73
73
1593
1719
80
80
80
1647
1815
79
79
79
1716
1926

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

ASC Steel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 Slab Weight: 36.3 psf
Gauge

22

20

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

238
268
268
2064
2274
350
350
350
2132
2383
349
349
349
2285
2620
347
347
347
2454
2873

207
238
238
2026
2219
280
311
311
2086
2318
309
309
309
2223
2533
307
307
307
2377
2764

182
182
182
1993
2173
247
278
278
2046
2262
277
277
277
2171
2458
275
275
275
2311
2671

161
161
161
1964
2132
220
251
251
2012
2213
250
250
250
2125
2394
248
248
248
2254
2590

144
144
144
1940
2097
197
197
197
1982
2171
195
227
227
2086
2337
225
225
225
2205
2519

128
128
128
1918
2066
177
177
177
1956
2133
176
207
207
2050
2287
206
206
206
2161
2457

115
115
115
1898
2038
160
160
160
1932
2100
159
190
190
2019
2243
157
189
189
2121
2401

104
104
104
1881
2013
145
145
145
1911
2070
144
144
175
1991
2203
142
174
174
2087
2351

94
94
94
1865
1991
132
132
132
1892
2043
131
131
131
1966
2167
129
161
161
2055
2307

85
85
85
1851
1970
121
121
121
1875
2019
119
119
119
1943
2135
118
118
150
2027
2266

77
77
77
1838
1952
110
110
110
1860
1997
109
109
109
1923
2106
108
108
108
2001
2229

70
70
70
1826
1935
101
101
101
1846
1977
100
100
100
1904
2079
99
99
99
1977
2196

64
64
64
1815
1920
93
93
93
1833
1958
92
92
92
1887
2054
91
91
91
1955
2165

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5
Gauge

22

20

18

16

1 Hour Fire Rating

Slab Weight: 48.4 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

308
348
348
2542
2752
414
455
455
2610
2862
451
451
451
2763
3098
447
447
447
2932
3351

269
269
269
2504
2697
363
403
403
2564
2796
400
400
400
2702
3011
396
396
396
2855
3242

236
236
236
2471
2651
321
361
361
2524
2740
358
358
358
2649
2936
355
355
355
2789
3149

209
209
209
2443
2610
285
285
285
2490
2692
282
323
323
2604
2872
320
320
320
2733
3068

186
186
186
2418
2575
255
255
255
2460
2649
252
293
293
2564
2815
290
290
290
2683
2997

166
166
166
2396
2544
229
229
229
2434
2612
227
227
268
2529
2765
224
265
265
2639
2935

149
149
149
2376
2516
207
207
207
2410
2578
205
205
205
2497
2721
202
243
243
2600
2879

135
135
135
2359
2491
188
188
188
2389
2548
186
186
186
2469
2681
183
183
224
2565
2830

122
122
122
2343
2469
171
171
171
2371
2522
169
169
169
2444
2645
166
166
208
2533
2785

110
110
110
2329
2449
156
156
156
2353
2497
154
154
154
2422
2613
152
152
152
2505
2744

100
100
100
2316
2430
143
143
143
2338
2475
141
141
141
2401
2584
139
139
139
2479
2708

91
91
91
2304
2413
131
131
131
2324
2455
129
129
129
2382
2557
127
127
127
2455
2674

82
82
82
2293
2398
120
120
120
2311
2437
118
118
118
2365
2532
116
116
116
2434
2643

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 5

Preformed Metal Floor Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2
Gauge

22

20

18

16

1 1/2 Hour Fire Rating

Slab Weight: 54.4 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

345
389
345
2781
2991
464
509
509
2849
3101
504
504
504
3002
3337
500
500
500
3171
3590

301
301
301
2743
2937
406
451
451
2803
3035
447
447
447
2941
3250
443
443
443
3094
3481

264
264
264
2710
2890
359
359
404
2763
2979
355
400
400
2888
3176
396
396
396
3029
3388

234
234
234
2682
2849
319
319
319
2729
2931
315
361
361
2843
3111
357
357
357
2972
3307

208
208
208
2657
2814
285
285
285
2699
2888
282
328
328
2803
3054
278
324
324
2922
3236

186
186
186
2635
2783
257
257
257
2673
2851
254
254
254
2768
3004
250
296
296
2878
3174

167
167
167
2615
2755
232
232
232
2649
2817
229
229
229
2737
2760
226
226
272
2839
3118

151
151
151
2598
2730
210
210
210
2628
2787
208
208
208
2709
2920
205
205
251
2804
3069

136
136
136
2582
2708
191
191
191
2610
2761
189
189
189
2683
2885
186
186
186
2772
3024

123
123
123
2568
2688
174
174
174
2593
2736
172
172
172
2661
2852
169
169
169
2744
2983

112
112
112
2555
2669
159
159
159
2577
2714
157
157
157
2640
2823
155
155
155
2718
2947

101
101
101
2543
2652
146
146
146
2563
2694
144
144
144
2621
2796
142
142
142
2694
2913

92
92
92
2532
2637
134
134
134
2550
2676
132
132
132
2604
2771
130
130
130
2673
2882

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6
Gauge

22

20

18

16

2 Hour Fire Rating

Slab Weight: 60.4 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

382
382
382
3020
3230
513
563
563
3088
3340
559
559
559
3241
3576
553
553
553
3410
3829

333
333
333
2982
3176
450
499
499
3042
3274
495
495
495
3180
3489
490
490
490
3333
3720

293
293
293
2949
3129
397
397
397
3002
3218
393
443
443
3127
3415
439
439
439
3268
3627

259
259
259
2921
3088
353
353
353
2968
3170
349
400
400
3082
3350
396
396
396
3211
3546

231
231
231
2896
3053
316
316
316
2928
3127
312
312
363
3042
3293
308
359
359
3161
3475

206
206
206
2874
3022
284
284
284
2912
3090
281
281
281
3007
3243
277
328
328
3117
3413

185
185
185
2854
2994
257
257
257
2889
3056
254
254
254
2976
3199
250
250
301
3078
3357

167
167
167
2837
2969
233
233
233
2868
3027
230
230
230
2948
3159
227
227
227
3043
3308

151
151
151
2821
2947
212
212
212
2849
3000
209
209
209
2923
3124
206
206
206
3011
3263

136
136
136
2807
2927
193
193
193
2832
2975
191
191
191
2900
3091
188
188
188
2983
3223

124
124
124
2794
2908
177
177
177
2816
2953
174
174
174
2879
3062
172
172
172
2957
3186

112
112
112
2782
2892
162
162
162
2802
2933
160
160
160
2860
3035
157
157
157
2933
3152

100
100
100
2771
2876
149
149
149
2789
2915
147
147
147
2843
3010
144
144
144
2912
3121

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

ASC Steel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 3/4
Gauge

22

20

18

16

3 Hour Fire Rating

Slab Weight: 69.5 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

438
438
438
3379
3589
589
646
646
3447
3698
641
641
641
3600
3935
634
634
634
3769
4188

382
382
382
3341
3534
516
516
516
3401
3633
511
568
568
3538
3848
563
563
563
3692
4079

336
336
336
3308
3488
456
456
456
3361
3577
451
509
509
3486
3773
503
503
503
3626
3986

297
297
297
3279
3447
405
405
405
3327
3528
401
401
459
3440
3709
396
454
454
3569
3905

265
265
265
3254
3412
363
363
363
3297
3486
359
359
359
3401
3652
354
412
412
3519
3834

237
237
237
3232
3380
326
326
326
3271
3448
322
322
322
3365
3602
318
318
376
3476
3772

213
213
213
3213
3353
295
295
295
3247
3415
291
291
291
3334
3588
287
287
287
3436
3716

191
191
191
3195
3328
267
267
267
3226
3385
264
264
264
3306
3518
260
260
260
3401
3666

173
173
173
3180
3306
243
243
243
3207
3358
240
240
240
3281
3482
237
237
237
3370
3622

157
157
157
3166
3285
222
222
222
3190
3334
219
219
219
3238
3450
216
216
216
3342
3581

142
142
142
3153
3267
203
203
203
3175
3312
200
200
200
3258
3421
197
197
197
3316
3544

127
127
127
3141
3280
186
186
186
3160
3292
184
184
184
3219
3394
181
181
181
3292
3511

112
112
112
3130
3235
171
171
171
3147
3273
168
168
168
3201
3369
166
166
166
3270
3480

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 7

Preformed Metal Floor Deck

N-24 Composite Floor Deck


8

2-5/8

5-3/8

N-24 Allowable Reactions (plf)

Gauge
1

1 1/2

Bearing Length
2
2 1/2

3 1/2

22

6
24

2 Welds

4 Welds
F

N-24 Section Properties


Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

22
2.18
0.771
0.361
0.449
20
2.58
0.945
0.467
0.554
18
3.40
1.330
0.689
0.765
16
4.22
1.716
0.882
0.949
1. Section properties are based on minimum 38 ksi steel (Fy)

292
328
365
402
438
475
512
728
797
876
985
1093
1202 1310
20
501
556
610
665
720
774
829
1095
1184
1274
1389 1530
1670 1811
18
1057
1148
1240
1331 1423
1514 1606
2035
2165
2296
2426 2557
2762 2966
16
1805
1935
2064
2193 2323
2452 2582
3269
3440
3611
3783 3954
4125 4348
1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 Slab Weight: 26.3 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

80

195 177
195 177
195 177
1284 1271
1398 1373
257 233
257 233
257 233
1283 1268
1444 1415
260 236
260 236
260 236
1306 1287
1555 1516
262 238
262 238
262 238
1347 1322
1682 1632

86

90

161
161
161
1261
1352
213
213
213
1256
1389
215
215
215
1269
1481
217
217
217
1301
1589

148
148
148
1251
1332
195
195
195
1244
1366
197
197
197
1254
1450
199
199
199
1281
1551

Span
96 100 106 110 116 120 126 130 136 140 146 150

114
136
136
1242
1315
180
180
180
1234
1345
182
182
182
1240
1423
184
184
184
1264
1516

104
126
126
1235
1300
167
167
167
1224
1326
169
169
169
1228
1398
170
170
170
1249
1485

95
117
117
1228
1286
155
155
155
1216
1309
157
157
157
1216
1376
158
158
158
1235
1457

87
110
110
1221
1273
144
144
144
1208
1294
146
146
146
1206
1355
147
147
147
1222
1431

80
102
102
1215
1261
112
135
135
1201
1280
137
137
137
1197
1337
138
138
138
1210
1408

73
73
73
1210
1251
104
127
127
1195
1267
128
128
128
1188
1320
129
129
129
1199
1387

68
68
68
1205
1241
96
119
119
1189
1255
121
121
121
1180
1304
122
122
122
1190
1367

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

63
63
63
1201
1232
89
89
112
1184
1245
114
144
114
1173
1289
115
115
115
1181
1349

58
58
58
1196
1223
83
83
103
1178
1234
107
107
107
1166
1276
108
108
108
1172
1332

54
54
54
1192
1216
78
78
78
1174
1225
78
102
102
1160
1263
103
103
103
1164
1317

50
50
50
1189
1208
72
72
72
1169
1216
73
97
97
1154
1252
97
97
97
1157
1302

46
46
46
1185
1201
68
68
68
1165
1208
68
68
91
1149
1241
68
93
93
1150
1289

156

160

43
43
43
1182
1195
63
63
63
1162
1201
64
64
83
1144
1231
64
88
88
1144
1276

40
40
40
1179
1189
59
59
59
1158
1194
60
60
76
1139
1221
60
84
84
1138
1264

ASC Steel Deck

N-24 Composite Floor Deck


N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/2

1 Hour Fire Rating

No. of
Gauge Spans 76

80

86

90

193
193
193
1429
1531
254
254
254
1427
1574
255
255
255
1444
1674
256
256
256
1480
1790

176
176
176
1419
1510
232
232
232
1414
1547
233
233
233
1427
1639
233
233
233
1459
1747

136
162
162
1409
1490
213
213
213
1402
1542
214
214
214
1412
1608
214
214
214
1439
1709

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

213
213
213
1442
1556
280
280
280
1441
1602
281
281
281
1464
1713
282
282
282
1505
1840

Slab Weight: 30.9 psf

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

49
49
49
1343
1359
72
72
72
1323
1366
72
72
99
1307
1399
72
100
100
1308
1447

45
45
45
1340
1353
67
67
67
1320
1359
67
67
95
1302
1389
67
95
95
1302
1434

42
42
42
1337
1347
63
63
63
1316
1352
63
63
63
1297
1379
62
62
90
1296
1422

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

50
50
50
1577
1590
75
75
75
1557
1596
75
75
75
1539
1626
74
74
107
1539
1671

46
46
46
1574
1584
70
70
70
1553
1588
70
70
70
1534
1616
69
69
102
1533
1659

123
149
149
1400
1473
196
196
196
1392
1503
197
197
197
1398
1581
198
198
198
1422
1674

112
138
138
1393
1458
182
182
182
1382
1484
182
182
182
1386
1556
183
183
183
1407
1643

102
128
128
1386
1444
169
169
169
1374
1467
170
170
170
1374
1534
170
170
170
1393
1615

93
120
120
1379
1431
131
157
157
1366
1452
158
158
158
1364
1513
159
159
159
1380
1589

86
86
86
1373
1419
121
147
147
1359
1438
148
148
148
1355
1495
148
148
148
1368
1566

79
79
79
1368
1409
110
138
138
1353
1425
139
139
139
1346
1478
139
139
139
1357
1545

73
73
73
1363
1399
103
103
130
1347
1413
131
131
131
1338
1462
131
131
131
1348
1525

67
67
67
1359
1390
96
96
123
1342
1403
123
123
123
1331
1447
123
123
123
1338
1507

62
62
62
1354
1381
89
89
89
1336
1392
89
116
116
1324
1434
117
117
117
1330
1490

57
57
57
1350
1374
83
83
83
1332
1383
83
110
110
1318
1421
110
110
110
1322
1475

53
53
53
1347
1366
77
77
77
1327
1374
77
77
105
1312
1410
77
105
105
1315
1460

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 1/4

2 Hour Fire Rating

No. of
Gauge Spans 76

80

86

90

221
221
221
1666
1768
290
290
290
1664
1810
290
290
290
1681
1911
289
289
289
1717
2027

170
202
202
1656
1747
265
265
265
1651
1784
264
264
264
1664
1876
264
264
264
1696
1984

154
185
185
1646
1727
243
243
243
1639
1761
243
243
243
1649
1845
242
242
242
1676
1946

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

244
244
244
1679
1793
319
319
319
1678
1839
319
319
319
1701
1950
318
318
318
1742
2077

139
171
171
1637
1710
224
224
224
1629
1740
224
224
224
1635
1818
223
223
223
1659
1911

Slab Weight: 37.8 psf

126
158
158
1630
1695
175
207
207
1619
1721
207
207
207
1623
1793
207
207
207
1644
1880

115
147
115
1623
1681
161
193
193
1611
1704
193
193
193
1611
1771
191
191
191
1629
1852

105
105
105
1616
1668
148
180
180
1603
1689
180
180
180
1601
1750
179
179
179
1617
1826

97
97
97
1610
1656
136
168
168
1596
1675
168
168
168
1592
1732
168
168
168
1605
1803

89
89
89
1605
1646
126
126
158
1590
1662
158
158
158
1583
1714
157
157
157
1594
1782

81
81
81
1600
1636
116
116
116
1584
1650
116
148
148
1575
1699
148
148
148
1585
1762

75
75
75
1596
1627
108
108
108
1578
1640
107
140
140
1568
1684
139
139
139
1575
1744

69
69
69
1591
1618
100
100
100
1573
1629
99
132
132
1561
1671
132
132
132
1567
1727

64
64
64
1587
1610
93
93
93
1569
1620
92
92
125
1555
1658
91
125
125
1559
1712

59
59
59
1584
1603
87
87
87
1564
1611
86
86
119
1549
1647
85
118
118
1552
1697

54
54
54
1580
1596
81
81
81
1560
1603
80
80
80
1544
1636
79
79
112
1545
1684

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 9

Preformed Metal Floor Deck

N-24 Composite Floor Deck


N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
TotAl Slab Thickness: 7 3/16 3 Hour Fire Rating Slab Weight: 46.3 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

286
286
286
1975
2089
374
374
374
1975
2135
372
372
372
1997
2246
370
370
370
2038
2373

80

86

90

221
259
259
1963
2065
339
339
339
1960
2106
338
338
338
1978
2207
336
336
336
2013
2324

198
217
217
1952
2043
310
310
310
1947
2080
309
309
309
1960
2172
307
307
307
1992
2280

179
200
200
1942
2024
284
284
284
1935
2057
283
283
283
1945
2142
281
281
281
1972
2242

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

62
62
62
1877
1893
93
93
93
1857
1899
92
92
92
1840
1932
91
91
131
1841
1980

57
57
57
1873
1886
87
87
87
1853
1892
86
86
86
1835
1922
84
84
125
1835
1967

53
53
53
1870
1880
81
81
81
1849
1885
80
80
80
1830
1913
78
78
78
1829
1955

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

36
36
36
1507
1520
57
57
57
1486
1525
57
57
57
1468
1555
57
57
88
1468
1600

33
33
33
1504
1514
52
52
52
1482
1518
53
53
53
1464
1546
53
53
84
1462
1588

162
162
162
1934
2006
223
262
262
1925
2036
261
261
261
1931
2114
260
260
260
1955
2207

147
147
147
1926
1991
204
243
243
1916
2017
242
242
242
1919
2089
240
240
240
1940
2176

134
134
134
1919
1977
187
226
226
1907
2001
225
225
225
1908
2067
223
223
223
1926
2148

122
122
122
1912
1964
172
172
210
1899
1985
210
210
210
1897
2046
208
208
208
1913
2123

112
112
112
1907
1952
158
158
158
1892
1971
157
196
196
1888
2028
195
195
195
1901
2099

103
103
103
1901
1942
146
146
146
1886
1958
144
184
184
1879
2011
183
183
183
1891
2078

94
94
94
1896
1932
135
135
135
1880
1947
133
173
173
1872
1995
172
172
172
1881
2058

87
87
87
1892
1923
125
125
125
1875
1936
124
124
163
1864
1980
162
162
162
1872
2040

80
80
80
1888
1914
116
116
116
1870
1926
115
115
154
1858
1967
113
153
153
1863
2023

73
73
73
1884
1907
108
108
108
1865
1916
106
106
146
1851
1955
105
145
145
1855
2008

68
68
68
1880
1899
100
100
100
1861
1908
99
99
99
1846
1943
97
97
138
1848
1993

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight (145 pcf)
Total Slab Thickness: 5 Slab Weight: 34.6 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

195
195
195
1608
1722
257
257
257
1608
1769
260
260
260
1631
1880
262
262
262
1671
2006

80

86

90

177
177
177
1596
1698
233
233
233
1593
1739
236
236
236
1611
1840
238
238
238
1647
1957

161
161
161
1585
1676
213
213
213
1580
1713
215
215
215
1594
1806
217
217
217
1625
1914

119
148
148
1575
1657
195
195
195
1563
1690
197
197
197
1578
1775
199
199
199
1606
1875

107
136
136
1567
1640
180
180
180
1558
1669
182
182
182
1564
1747
184
184
184
1589
1841

97
126
126
1559
1524
167
167
167
1549
1651
169
169
169
1552
1723
170
170
170
1573
1810

88
117
117
1552
1610
125
154
154
1540
1635
157
157
157
1541
1700
158
158
158
1559
1781

80
80
80
1546
1597
115
144
144
1533
1619
146
146
146
1531
1680
147
147
147
1546
1756

73
73
73
1540
1586
106
135
135
1526
1605
137
137
137
1521
1661
138
138
138
1535
1733

67
67
67
1534
1576
97
97
127
1519
1592
128
128
128
1513
1644
129
129
129
1524
1711

61
61
61
1530
1565
90
90
90
1513
1580
117
121
121
1505
1628
122
122
122
1514
1692

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

10

56
56
56
1525
1556
83
83
83
1508
1569
83
114
114
1498
1614
115
115
115
1505
1673

51
51
51
1521
1548
77
77
77
1503
1559
77
107
107
1491
1600
108
108
108
1497
1657

47
47
47
1517
1540
71
71
71
1498
1550
71
71
102
1485
1588
72
103
103
1488
1641

43
43
43
1513
1533
66
66
66
1494
1541
66
66
97
1479
1576
66
97
97
1481
1627

39
39
39
1510
1526
61
61
61
1490
1533
61
61
88
1473
1565
61
93
93
1475
1613

ASC Steel Deck

N-24 Composite Floor Deck


N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 Slab Weight: 40.7 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

213
213
213
1847
1962
280
280
280
1847
2008
281
281
281
1870
2119
282
282
282
1910
2245

80

86

90

193
193
193
1835
1937
254
254
254
1832
1978
255
255
255
1850
2079
256
256
256
1886
2196

142
176
176
1824
1915
232
232
232
1819
1952
233
233
233
1833
2045
233
233
233
1864
2153

128
162
162
1815
1896
213
213
213
1808
1929
214
214
214
1817
2014
214
214
214
1845
2114

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

41
41
41
1749
1765
64
64
64
1729
1772
64
64
64
1713
1805
64
64
100
1714
1852

37
37
37
1746
1759
59
59
59
1725
1764
59
59
59
1707
1794
59
59
95
1707
1839

34
34
34
1743
1753
55
55
55
1722
1754
55
55
55
1703
1785
54
54
54
1702
1828

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

42
42
42
2224
2237
68
68
68
2203
2242
67
67
67
2186
2273
66
66
66
2186
2318

37
37
37
2221
2231
63
63
63
2200
2235
62
62
62
2181
2263
61
61
61
2180
2306

115
149
149
1806
1879
196
196
196
1797
1908
197
197
197
1804
1986
198
198
198
1828
2080

104
138
138
1798
1863
147
182
182
1788
1890
182
182
182
1791
1962
183
183
183
1812
2049

94
94
94
1791
1849
134
169
169
1779
1873
170
170
170
1780
1939
170
170
170
1798
2021

86
86
86
1785
1836
123
157
157
1772
1858
158
158
158
1770
1919
159
159
159
1785
1995

78
78
78
1779
1825
113
113
147
1765
1844
148
148
148
1760
1900
148
148
148
1774
1972

71
71
71
1774
1814
104
104
104
1758
1831
104
139
139
1757
1883
139
139
139
1763
1950

65
65
65
1769
1804
95
95
95
1752
1819
95
131
131
1744
1867
131
131
131
1753
1931

59
59
59
1764
1795
88
88
88
1747
1808
88
123
123
1737
1853
123
123
123
1744
1913

54
54
54
1760
1787
81
81
81
1742
1798
81
81
116
1730
1839
81
117
117
1736
1896

49
49
49
1756
1779
75
75
75
1737
1789
75
75
110
1724
1827
75
110
110
1728
1880

45
45
45
1752
1772
69
69
69
1733
1780
69
69
105
1718
1815
69
105
105
1721
1866

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2 1 Hour Fire Rating Slab Weight: 52.7 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

254
254
254
2325
2440
333
333
333
2325
2486
333
333
333
2348
2597
331
331
331
2389
2723

80

86

90

187
231
231
2313
2415
303
303
303
2310
2456
302
302
302
2328
2558
301
301
301
2364
2674

167
211
211
2302
2393
276
276
276
2297
2430
276
276
276
2311
2523
275
275
275
2342
2631

150
194
194
2293
2374
210
254
254
2286
2407
253
253
253
2295
2492
252
252
252
2323
2592

135
135
135
2284
2357
190
234
234
2275
2387
233
233
233
2282
2465
233
233
233
2306
2558

122
122
122
2276
2341
173
217
217
2266
2368
216
216
216
2269
2440
215
215
215
2290
2527

110
110
110
2269
2327
157
157
201
2258
2351
201
201
201
2258
2417
200
200
200
2276
2499

100
100
100
2263
2315
144
144
144
2250
2336
143
187
187
2248
2397
187
187
187
2263
2473

90
90
90
2257
2303
132
132
132
2243
2322
131
175
175
2239
2378
175
175
175
2252
2450

82
82
82
2252
2292
121
121
121
2237
2309
120
164
164
2230
2361
164
164
164
2241
2429

74
74
74
2247
2282
111
111
111
2231
2297
110
110
155
2222
2346
106
154
154
2231
2409

68
68
68
2242
2273
102
102
102
2225
2286
101
101
146
2215
2331
100
145
145
2222
2391

62
62
62
2238
2265
94
94
94
2220
2276
93
93
93
2208
2318
92
92
137
2214
2374

56
56
56
2234
2257
87
87
87
2215
2267
86
86
86
2202
2305
85
85
130
2206
2358

51
51
51
2231
2250
80
80
80
2211
2258
79
79
79
2196
2294
78
78
123
2199
2344

46
46
46
2227
2243
74
74
74
2207
2250
73
73
73
2191
2283
72
72
72
2192
2330

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 11

Preformed Metal Floor Deck

N-24 Composite Floor Deck


N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1 1/2 Hour Fire Rating Slab Weight: 58.8 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

229
277
277
2565
2679
363
363
363
2564
2725
361
361
361
2587
2836
359
359
359
2628
2962

80

86

90

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

203
251
251
2552
2654
329
329
329
2549
2695
328
328
328
2567
2797
326
326
326
2603
2913

181
230
230
2541
2633
252
301
301
2536
2669
299
299
299
2550
2762
298
298
298
2581
2870

162
211
211
2532
2613
227
276
276
2525
2646
275
275
275
2535
2731
273
273
273
2562
2831

146
146
146
2523
2596
206
254
254
2514
2626
253
253
253
2521
2704
252
252
252
2545
2797

49
49
49
2466
2482
79
79
79
2446
2489
78
78
78
2430
2522
77
77
77
2431
2569

44
44
44
2463
2476
73
73
73
2442
2481
72
72
72
2425
2512
71
71
71
2425
2557

40
40
40
2460
2470
67
67
67
2439
2474
66
66
66
2420
2502
65
65
65
2419
2545

131
131
131
2515
2581
187
236
236
2505
2607
235
235
235
2508
2679
233
233
233
2529
2766

119
119
119
2508
2566
170
170
219
2497
2590
218
218
218
2497
2656
217
217
217
2515
2738

107
107
107
2502
2554
155
155
155
2489
2575
154
203
203
2487
2636
202
202
202
2503
2712

97
97
97
2496
2542
142
142
142
2482
2561
141
190
190
2478
2617
189
189
189
2491
2689

88
88
88
2491
2531
130
130
130
2476
2548
129
129
179
2469
2600
127
178
178
2480
2668

80
80
80
2486
2522
120
120
120
2470
2536
118
118
168
2461
2585
117
167
167
2470
2648

73
73
73
2481
2513
110
110
110
2464
2525
109
109
109
2454
2570
107
107
157
2461
2630

66
66
66
2477
2504
101
101
101
2459
2515
100
100
100
2447
2557
99
99
149
2453
2613

60
60
60
2473
2496
93
93
93
2455
2506
92
92
92
2441
2544
91
91
141
2445
2597

54
54
54
2470
2489
86
86
86
2450
2497
85
85
85
2435
2533
83
83
83
2438
2583

N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/2 2 Hour Fire Rating Slab Weight: 64.9 psf
No. of
Gauge Spans 76

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

247
300
300
2804
2918
393
393
393
2803
2964
391
391
391
2826
3075
388
388
388
2867
3201

80

86

90

Span
96 100 106 110 116 120 126 130 136 140 146 150

156

160

219
273
273
2791
2893
357
357
357
2789
2935
355
355
355
2806
3036
352
352
352
2842
3152

196
249
249
2781
2872
272
326
326
2775
2909
324
324
324
2789
3001
322
322
322
2820
3109

175
175
175
2771
2852
245
299
299
2764
2885
297
297
297
2774
2970
295
295
295
2801
3070

157
157
157
2762
2835
222
276
276
2754
2865
274
274
274
2760
2943
272
272
272
2784
3036

47
47
47
2702
2715
78
78
78
2681
2721
77
77
77
2664
2751
76
76
76
2664
2796

42
42
42
2699
2709
72
72
72
2678
2713
71
71
71
2659
2741
69
69
69
2658
2784

142
142
142
2754
2820
202
202
255
2744
2846
254
254
254
2747
2918
252
252
252
2768
3005

128
128
128
2747
2806
184
184
184
2736
2829
182
236
236
2736
2896
234
234
234
2754
2977

116
116
116
2741
2793
168
168
168
2728
2814
166
220
220
2726
2875
219
219
219
2742
2951

105
105
105
2735
2781
153
153
153
2721
2800
152
152
206
2717
2856
204
204
204
2730
2928

98
98
98
2730
2770
140
140
140
2715
2787
139
139
193
2708
2839
137
192
192
2719
2907

86
86
86
2725
2761
129
129
129
2709
2775
127
127
182
2700
2824
125
180
180
2709
2887

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

12

78
78
78
2720
2752
118
118
118
2703
2764
117
117
117
2693
2809
115
115
170
2700
2869

71
71
71
2716
2743
109
109
109
2698
2754
107
107
107
2686
2796
106
106
161
2692
2852

64
64
64
2712
2735
100
100
100
2694
2745
99
99
99
2680
2783
97
97
97
2684
2837

58
58
58
2709
2728
92
92
92
2689
2736
91
91
91
2674
2772
89
89
89
2677
2822

52
52
52
2705
2721
85
85
85
2685
2728
84
84
84
2669
2761
82
82
82
2670
2808

ASC Steel Deck

N-24 Composite Floor Deck


N-24 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 8 1/4

3 Hour Fire Rating

No. of
Gauge Spans 76

80

86

90

245
305
305
3150
3252
338
399
399
3147
3293
396
396
396
3165
3394
393
393
393
3201
3511

218
218
218
3139
3230
304
364
364
3134
3267
362
362
362
3148
3360
330
330
330
3179
3468

195
195
195
3129
3211
274
334
334
3123
3244
332
332
332
3132
3329
304
304
304
3160
3429

22

20

18

16

1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4
1
2
3
q2
q4

276
336
336
3162
3276
439
439
439
3162
3323
437
437
437
3185
3434
433
433
433
3225
3560

Slab Weight: 74.0 psf

Span
96 100 106 110 116 120 126 130 136 140 146 150

175
175
175
3121
3194
248
248
308
3112
3223
306
306
306
3118
3301
281
281
281
3143
3395

158
158
158
3113
3178
225
225
225
3103
3205
222
284
284
3106
3277
262
262
262
3127
3364

142
142
142
3106
3164
205
205
205
3094
3188
202
264
264
3095
3254
244
244
244
3113
3335

129
129
129
3100
3151
187
187
187
3087
3173
184
184
246
3085
3234
182
228
228
3100
3310

117
117
117
3094
3140
171
171
171
3080
3159
169
169
230
3075
3215
166
166
214
3089
3287

106
106
106
3089
3129
156
156
156
3073
3146
154
154
154
3067
3198
152
152
201
3078
3265

96
96
96
3084
3119
143
143
143
3067
3134
141
141
141
3059
3182
139
139
190
3068
3246

87
87
87
3079
3110
132
132
132
3062
3123
130
130
130
3052
3168
128
128
128
3059
3228

78
78
78
3075
3102
121
121
121
3057
3113
119
119
119
3045
3154
117
117
117
3051
3211

71
71
71
3071
3094
111
111
111
3052
3104
110
110
110
3039
3142
108
108
108
3043
3195

64
64
64
3067
3087
102
102
102
3048
3095
101
101
101
3033
3130
99
99
99
3036
3181

58
58
58
3064
3080
94
94
94
3044
3087
93
93
93
3028
3120
91
91
91
3029
3168

156

160

52
52
52
3061
3074
87
87
87
3040
3079
85
85
85
3022
3109
83
83
83
3022
3154

47
47
47
3058
3068
80
80
80
3036
3072
78
78
78
3018
3100
77
77
77
3016
3142

1. In shaded areas, mid-span deck shoring required during construction.


2. q2 and q4 q=allowable diaphragm shear (plf): 2, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 13

Preformed Metal Floor Deck

2W Composite Floor Deck


12

2W - Allowable Reactions (plf)

Gauge

22
2-1/8

21

20

36
3 Welds 4 Welds
2W also available in 24 coverage

19

2W - Section PropertiesF
Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

18

22
21
20
19
18
16

1.63
1.73
1.95
2.28
2.57
3.21

0.380
0.423
0.465
0.543
0.601
0.752

0.298
0.338
0.397
0.464
0.535
0.670

0.339
0.376
0.411
0.481
0.538
0.670

16

1 1/2

164
415
242
552
286
628
464
930
615
1181
1054
1902

185
455
271
601
318
680
509
997
669
1258
1130
2003

Bearing Length
2
2 1/2

206
504
299
645
350
733
554
1063
723
1334
1207
2104

227
567
327
721
382
804
598
1130
777
1411
1283
2205

3 1/2

248
631
355
797
414
886
643
1224
831
1493
1360
2306

269
694
384
873
446
968
688
1329
884
1613
1436
2407

291
758
412
949
477
1051
732
1433
938
1733
1512
2544

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4 Slab Weight: 27.6 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

243
243
243
1348
1493
259
259
259
1357
1537
267
267
267
1364
1560
299
299
299
1393
1647
323
323
323
1419
1714
392
392
392
1493
1883

210
210
210
1328
1456
223
223
223
1334
1494
231
231
231
1339
1515
259
259
259
1363
1593
280
280
280
1386
1653
342
342
342
1451
1807

183
183
183
1310
1424
195
195
195
1314
1458
202
202
202
1317
1476
227
227
227
1338
1547
246
246
246
1357
1601
301
301
301
1415
1742

161
161
161
1294
1396
172
172
172
1296
1426
178
178
178
1299
1443
200
200
200
1315
1507
218
218
218
1332
1556
268
268
268
1383
1685

119
143
143
1281
1372
153
153
153
1281
1399
158
158
158
1283
1414
178
178
178
1296
1471
194
194
194
1310
1517
240
240
240
1356
1636

104
127
127
1269
1351
137
137
137
1267
1374
142
142
142
1268
1388
160
160
160
1279
1440
175
175
175
1291
1482
216
216
216
1332
1592

91
115
115
1259
1332
99
123
123
1255
1353
128
128
128
1256
1365
145
145
145
1263
1413
158
158
158
1274
1452
196
196
196
1310
1554

80
104
104
1249
1315
88
111
111
1245
1333
92
116
116
1244
1344
131
131
131
1250
1388
143
143
143
1259
1424
179
179
179
1291
1519

71
71
71
1241
1299
78
101
101
1235
1316
81
105
105
1234
1326
120
120
120
1237
1366
131
131
131
1245
1399
164
164
164
1274
1488

62
62
62
1233
1285
69
69
93
1226
1300
72
96
96
1225
1309
110
110
110
1226
1346
120
120
120
1232
1377
151
151
151
1258
1460

55
55
55
1226
1273
61
61
61
1218
1286
64
64
88
1216
1294
77
93
93
1216
1328
111
111
111
1221
1356
139
139
139
1244
1434

49
49
49
1220
1261
55
55
55
1211
1273
58
58
58
1208
1280
69
69
86
1207
1311
78
102
102
1201
1338
129
129
129
1231
1411

43
43
43
1214
1251
49
49
49
1204
1261
51
51
51
1201
1267
62
62
62
1198
1296
71
95
95
1192
1320
95
120
120
1219
1389

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

14

ASC Steel Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4 1/2 1 Hour Fire Rating Slab Weight: 32.1 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

273
273
273
1506
1651
291
291
291
1515
1695
300
300
300
1522
1718
335
335
335
1551
1805
361
361
361
1577
1872
437
437
437
1651
2041

236
236
236
1486
1614
251
251
251
1492
1652
259
259
259
1497
1673
290
290
290
1521
1751
314
314
314
1544
1811
381
381
381
1609
1965

205
205
205
1468
1582
219
219
219
1472
1616
226
226
226
1475
1634
254
254
254
1495
1705
275
275
275
1515
1759
336
336
336
1573
1900

181
181
181
1452
1554
193
193
193
1454
1584
200
200
200
1457
1601
224
224
224
1473
1665
244
244
244
1490
1714
299
299
299
1541
1843

133
160
160
1439
1530
172
172
172
1439
1557
177
177
177
1441
1571
200
200
200
1454
1629
217
217
217
1468
1675
267
267
267
1514
1794

116
143
143
1427
1509
126
153
153
1425
1532
159
159
159
1426
1546
179
179
179
1437
1598
195
195
195
1449
1640
241
241
241
1490
1750

102
129
129
1417
1490
111
138
138
1413
1511
116
143
143
1414
1523
162
162
162
1421
1571
177
177
177
1432
1610
219
219
219
1468
1712

89
89
89
1407
1473
98
125
125
1403
1491
102
130
130
1402
1502
147
147
147
1408
1546
161
161
161
1417
1582
200
200
200
1449
1677

79
79
79
1399
1457
86
114
114
1393
1474
91
118
118
1392
1484
134
134
134
1395
1524
147
147
147
1403
1557
183
183
183
1432
1646

70
70
70
1391
1443
77
77
77
1384
1458
80
80
108
1383
1467
95
123
123
1384
1504
135
135
135
1390
1535
168
168
168
1416
1618

61
61
61
1384
1431
68
68
68
1376
1444
72
72
72
1374
1452
85
113
113
1374
1486
96
124
124
1379
1514
155
155
155
1402
1592

54
54
54
1378
1419
61
61
61
1369
1431
64
64
64
1366
1438
76
76
104
1365
1469
86
115
115
1369
1496
144
144
144
1387
1569

48
48
48
1372
1409
54
54
54
1362
1419
57
57
57
1359
1425
69
69
97
1356
1454
78
78
106
1359
1478
105
134
134
1377
1547

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 15

Preformed Metal Floor Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/4 2 Hour Fire Rating Slab Weight: 38.9 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

322
322
322
1743
1888
342
342
342
1752
1932
353
353
353
1759
1955
393
393
393
1788
2042
424
424
424
1814
2109
511
511
511
1888
2278

278
278
278
1723
1851
295
295
295
1729
1889
305
305
305
1734
1910
340
340
340
1758
1988
368
368
368
1781
2048
445
445
445
1846
2202

242
242
242
1705
1819
258
258
258
1709
1853
266
266
266
1712
1871
298
298
298
1732
1942
323
323
323
1752
1996
393
393
393
1809
2137

180
213
213
1689
1791
227
227
227
1691
1821
235
235
235
1694
1838
263
263
263
1710
1902
286
286
286
1727
1951
349
349
349
1778
2080

156
189
189
1676
1767
169
202
202
1676
1794
209
209
209
1678
1808
235
235
235
1691
1866
255
255
255
1705
1912
313
313
313
1751
2031

136
169
169
1664
1746
148
181
181
1662
1769
154
187
187
1663
1783
210
210
210
1674
1835
229
229
229
1686
1877
282
282
282
1727
1987

119
119
119
1654
1726
130
163
163
1650
1748
135
168
168
1650
1760
190
190
190
1658
1808
207
207
207
1669
1847
256
256
256
1705
1949

105
105
105
1644
1709
114
147
147
1640
1728
119
152
152
1639
1739
172
172
172
1645
1783
188
188
188
1654
1819
233
233
233
1686
1914

92
92
92
1636
1694
101
101
101
1630
1711
106
106
139
1629
1721
124
157
157
1632
1761
172
172
172
1640
1794
214
214
214
1669
1883

81
81
81
1628
1680
90
90
90
1621
1695
94
94
94
1620
1704
111
144
144
1621
1741
124
158
158
1627
1772
197
197
197
1653
1855

72
72
72
1621
1668
79
79
79
1613
1681
84
84
84
1611
1689
99
99
133
1611
1723
112
145
145
1616
1751
182
182
182
1639
1829

63
63
63
1615
1656
71
71
71
1606
1668
74
74
74
1603
1675
89
89
123
1602
1706
101
101
134
1606
1733
134
168
168
1626
1806

56
56
56
1609
1646
63
63
63
1599
1656
66
66
66
1596
1662
80
80
80
1593
1691
91
91
125
1596
1715
122
157
157
1614
1784

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

16

ASC Steel Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 3/16
Gauge

22

21

20

19

18

16

3 Hour Fire Rating

Slab Weight: 47.5 psf

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

385
385
385
2039
2184
409
409
409
2049
2228
422
422
422
2055
2251
469
469
469
2084
2338
506
506
506
2110
2405
609
609
609
2184
2574

332
332
332
2019
2147
353
353
353
2025
2185
365
365
365
2030
2206
407
407
407
2054
2284
439
439
439
2077
2344
531
531
531
2142
2498

250
290
290
2001
2115
308
308
308
2005
2149
318
318
318
2009
2167
356
356
356
2029
2238
385
385
385
2048
2293
468
468
468
2106
2433

215
255
255
1986
2087
232
272
272
1987
2117
281
281
281
1990
2134
315
315
315
2006
2198
341
341
341
2023
2248
416
416
416
2074
2376

187
226
226
1972
2063
202
241
241
1972
2090
210
250
250
1974
2105
280
280
280
1987
2163
304
304
304
2001
2208
373
373
373
2047
2327

162
162
162
1960
2042
176
216
216
1958
2065
184
223
223
1959
2079
252
252
252
1970
2132
274
274
274
1982
2174
336
336
336
2023
2284

142
142
142
1950
2023
155
155
194
1946
2044
161
201
201
1947
2056
227
227
227
1954
2104
247
247
247
1965
2143
305
305
305
2001
2245

125
125
125
1940
2006
136
136
136
1936
2024
143
143
182
1935
2035
166
206
206
1941
2079
225
225
225
1950
2115
278
278
278
1982
2210

110
110
110
1932
1990
121
121
121
1926
2007
126
126
126
1925
2017
148
188
188
1928
2057
165
205
205
1936
2090
255
255
255
1965
2179

97
97
97
1924
1976
107
107
107
1917
1991
112
112
112
1916
2000
132
132
172
1917
2037
148
188
188
1923
2068
235
235
235
1949

86
86
86
1917
1964
95
95
95
1909
1977
100
100
100
1907
1985
118
118
159
1907
2019
133
133
174
1912
2047
176
217
217
1935

76
76
76
1911
1952
84
84
84
1902
1964
89
89
89
1900
1971
106
106
106
1898
2002
120
120
160
1902
2029
160
201
201
1922

67
67
67
1905
1942
75
75
75
1895
1952
79
79
79
1893
1958
95
95
95
1890
1987
108
108
108
1892
2012
146
146
187
1910

2151

2125

2102

2080

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 17

Preformed Metal Floor Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 Slab Weight: 36.4 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

243
243
243
1673
1818
259
259
259
1682
1861
267
267
267
1688
1884
299
299
299
1718
1972
323
323
323
1744
2038
392
392
392
1817
2207

210
210
210
1652
1780
223
223
223
1658
1819
231
231
231
1663
1839
259
259
259
1688
1918
280
280
280
1710
1978
342
342
342
1775
2131

183
183
183
1634
1748
195
195
195
1638
1782
202
202
202
1642
1801
227
227
227
1662
1871
246
246
246
1681
1926
301
301
301
1739
2066

130
160
160
1619
1721
172
172
172
1621
1751
178
178
178
1623
1767
200
200
200
1640
1831
218
218
218
1656
1881
268
268
268
1708
2010

112
143
143
1605
1696
153
153
153
1605
1723
158
158
158
1607
1738
178
178
178
1620
1796
194
194
194
1635
1842
240
240
240
1680
1960

97
127
127
1594
1675
106
137
137
1592
1699
110
142
142
1593
1712
160
160
160
1603
1765
175
175
175
1615
1807
216
216
216
1656
1917

84
115
84
1583
1656
92
123
123
1580
1677
96
128
128
1580
1689
145
145
145
1588
1737
158
158
158
1598
1776
196
196
196
1635
1878

73
73
73
1574
1639
80
111
111
1569
1658
84
116
116
1569
1669
131
131
131
1574
1713
143
143
143
1583
1748
179
179
179
1616
1843

63
63
63
1565
1624
70
70
70
1559
1640
74
74
105
1558
1650
88
120
120
1562
1690
131
131
131
1569
1724
164
164
164
1598
1812

55
55
55
1557
1610
62
62
62
1551
1624
65
65
65
1549
1633
78
110
110
1551
1670
120
120
120
1557
1701
151
151
151
1583
1784

48
48
48
1550
1597
54
54
54
1543
1610
57
57
57
1541
1618
69
69
101
1541
1652
79
111
111
1545
1681
139
139
139
1568
1758

42
42
42
1544
1586
47
47
47
1535
1597
50
50
50
1533
1604
62
62
93
1531
1635
71
71
102
1535
1662
97
129
129
1555
1735

36
36
36
1538
1575
41
41
41
1529
1585
44
44
44
1526
1592
55
55
55
1523
1620
63
63
95
1526
1645
88
120
120
1543
1714

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

18

ASC Steel Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 1/2 Slab Weight: 42.3 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

273

236

170

145

125

108

93

81

70

61

53

46

40

2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

273
273
1912
2057
291
291
291
1921
2100
300
300
300
1927
2123
335
335
335
1957
2211
361
361
361
1983
2277
437
437
437
2056
2446

236
236
1891
2020
251
251
251
1897
2058
259
259
259
1902
2078
290
290
290
1927
2157
314
314
314
1949
2217
381
381
381
2014
2370

205
205
1873
1988
219
219
219
1877
2021
226
226
226
1881
2040
254
254
254
1901
2110
275
275
275
1920
2165
336
336
336
1978
2305

181
181
1858
1960
193
193
193
1860
1990
200
200
200
1862
2006
224
224
224
1879
2070
244
244
244
1896
2120
299
299
299
1947
2249

160
160
1845
1936
136
172
172
1844
1962
177
177
177
1846
1977
200
200
200
1859
2035
217
217
217
1874
2081
267
267
267
1919
2199

143
143
1833
1914
118
153
153
1831
1938
123
159
159
1832
1951
179
179
179
1842
2004
195
195
195
1854
2046
241
241
241
1895
2156

93
93
1822
1895
102
138
138
1819
1916
107
143
143
1819
1928
162
162
162
1827
1976
177
177
177
1837
2015
219
219
219
1874
2117

81
81
1813
1878
89
89
125
1808
1897
94
94
130
1808
1908
111
147
147
1813
1952
161
161
161
1822
1988
200
200
200
1855
2083

70
70
1804
1863
78
78
78
1798
1879
82
82
118
1797
1889
98
134
134
1801
1930
147
147
147
1808
1963
183
183
183
1837
2051

61
61
1797
1849
68
68
68
1790
1864
72
72
72
1788
1872
87
87
123
1790
1910
98
135
135
1796
1940
168
168
168
1822
2023

53
53
1790
1836
60
60
60
1782
1849
63
63
63
1780
1857
77
77
113
1780
1891
87
87
124
1785
1920
118
155
155
1807
1998

46
46
1783
1825
52
52
52
1774
1836
56
56
56
1772
1843
68
68
68
1770
1875
78
78
115
1774
1901
107
144
144
1794
1974

40
40
1777
1814
46
46
46
1768
1824
49
49
49
1765
1831
60
60
60
1762
1859
70
70
70
1765
1884
97
134
134
1783
1953

120

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 19

Preformed Metal Floor Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 1 Hour Fire Rating
Slab Weight: 54.4 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

339
339
339
2390
2535
360
360
360
2399
2578
371
371
371
2405
2602
413
413
413
2435
2689
445
445
445
2461
2755
536
536
536
2534
2924

247
292
292
2369
2498
311
311
311
2376
2536
320
320
320
2380
2557
358
358
358
2405
2635
386
386
386
2427
2695
468
468
468
2492
2848

209
254
254
2352
2466
271
271
271
2355
2499
280
280
280
2359
2518
313
313
313
2379
2588
339
339
339
2399
2643
412
412
412
2456
2783

179
224
224
2336
2438
194
239
239
2338
2468
201
247
247
2341
2484
277
277
277
2357
2548
300
300
300
2374
2598
367
367
367
2425
2727

153
153
153
2323
2414
167
212
212
2323
2440
174
219
219
2324
2455
247
247
247
2337
2513
268
268
268
2352
2559
328
328
328
2398
2678

132
132
132
2311
2392
145
145
190
2309
2416
151
196
196
2310
2429
221
221
221
2320
2482
241
241
241
2333
2524
296
296
296
2373
2634

114
114
114
2300
2373
126
126
126
2297
2394
132
132
177
2297
2406
154
200
200
2305
2455
218
218
218
2316
2493
269
269
269
2352
2595

99
99
99
2291
2356
109
109
109
2286
2375
115
115
115
2286
2386
136
181
181
2291
2430
152
198
198
2300
2466
245
245
245
2333
2561

86
86
86
2282
2341
95
95
95
2277
2357
101
101
101
2276
2367
120
120
165
2279
2408
135
181
181
2286
2441
224
224
224
2315
2530

75
75
75
2275
2327
83
83
83
2268
2342
88
88
88
2266
2351
106
106
152
2268
2388
120
120
166
2274
2418
160
207
207
2300
2501

65
65
65
2268
2314
73
73
73
2260
2327
77
77
77
2258
2335
94
94
94
2258
2369
107
107
153
2263
2398
144
191
191
2286
2476

56
56
56
2261
2303
63
63
63
2253
2314
68
68
68
2256
2322
83
83
83
2249
2353
95
95
95
2252
2379
130
130
177
2273
2452

48
48
48
2255
2292
55
55
55
2246
2302
59
59
59
2243
2309
73
73
73
2240
2337
85
85
85
2243
2362
118
118
164
2261
2431

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

20

ASC Steel Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1 1/2 Hour Fire Rating Slab Weight: 60.4 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

373
373
373
2629
2774
396
396
396
2638
2817
408
408
408
2645
2841
454
454
454
2674
2928
489
489
489
2700
2995
589
589
589
2773
3164

271
321
321
2608
2737
342
342
342
2615
2775
352
352
352
2620
2796
393
393
393
2644
2874
425
425
425
2666
2934
514
514
514
2731
3088

230
280
280
2591
2705
248
298
298
2594
2739
308
308
308
2598
2757
344
344
344
2618
2828
373
373
373
2638
2882
453
453
453
2695
3022

196
246
246
2575
2677
213
263
263
2577
2707
221
271
271
2580
2724
304
304
304
2596
2787
330
330
330
2613
2837
403
403
403
2664
2966

169
169
169
2562
2653
183
233
233
2562
2679
191
241
241
2563
2694
271
271
271
2577
2752
294
294
294
2591
2798
361
361
361
2637
2917

145
145
145
2550
2631
159
159
209
2548
2655
166
166
216
2549
2668
193
243
243
2559
2721
265
265
265
2572
2763
325
325
325
2613
2873

126
126
126
2539
2612
138
138
138
2536
2633
144
144
144
2536
2645
169
220
220
2544
2694
188
239
239
2555
2732
295
295
295
2591
2834

109
109
109
2530
2595
120
120
120
2525
2614
126
126
126
2525
2625
149
149
199
2530
2669
167
217
217
2539
2705
269
269
269
2572
2800

94
94
94
2521
2580
105
105
105
2516
2597
110
110
110
2516
2606
131
131
182
2518
2647
148
148
199
2526
2680
195
246
246
2555
2769

82
82
82
2514
2566
91
91
91
2507
2581
97
97
97
2505
2590
116
116
116
2507
2627
131
131
182
2513
2657
175
227
227
2539
2740

71
71
71
2507
2554
80
80
80
2499
2566
85
85
85
2497
2574
103
103
103
2497
2609
117
117
117
2502
2637
158
158
210
2525
2715

61
61
61
2500
2542
70
70
70
2492
2553
74
74
74
2489
2561
91
91
91
2488
2592
104
104
104
2491
2618
143
143
194
2512
2691

53
53
53
2495
2531
60
60
60
2485
2541
65
65
65
2482
2548
80
80
80
2479
2577
93
93
93
2482
2601
129
129
129
2500
2670

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 21

Preformed Metal Floor Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2 2 Hour Fire Rating Slab Weight: 66.5 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

352
407
407
2868
3013
432
432
432
2877
3057
446
446
446
2884
3080
495
495
495
2913
3167
534
534
534
2939
3234
643
643
643
3013
3403

296
351
351
2847
2976
373
373
373
2854
3014
385
385
385
2859
3035
429
429
429
2883
3113
464
464
464
2906
3173
561
561
561
2970
3327

251
306
306
2830
2944
271
326
326
2834
2978
281
336
336
2837
2996
376
376
376
2857
3067
407
407
407
2877
3121
494
494
494
2934
3262

214
214
214
2814
2916
232
287
287
2816
2946
242
296
296
2819
2963
332
332
332
2835
3026
360
360
360
2852
3076
439
439
439
2903
3205

184
184
184
2801
2892
200
200
255
2801
2919
209
264
264
2802
2933
241
296
296
2816
2991
321
321
321
2830
3037
394
394
394
2876
3156

159
159
159
2789
2870
173
173
173
2787
2894
181
181
236
2788
2908
210
266
266
2798
2960
289
289
289
2811
3002
355
355
355
2852
3112

137
137
137
2769
2851
150
150
150
2775
2872
158
158
158
2775
2885
184
184
240
2783
2933
206
261
261
2778
2971
322
322
322
2830
3074

119
119
119
2761
2834
131
131
131
2764
2853
138
138
138
2764
2864
162
162
218
2769
2908
182
182
237
2765
2944
294
294
294
2811
3039

103
103
103
2753
2819
114
114
114
2755
2836
120
120
120
2754
2846
143
143
143
2757
2886
161
161
217
2752
2919
213
269
269
2794
3008

89
89
89
2746
2805
100
100
100
2746
2820
105
105
105
2744
2829
126
126
126
2746
2866
143
143
143
2741
2897
191
191
248
2778
2979

77
77
77
2739
2793
87
87
87
2738
2806
92
92
92
2736
2814
112
112
112
2736
2848
128
128
128
2731
2876
172
172
229
2764
2954

67
67
67
2734
2781
76
76
76
2731
2792
81
81
81
2728
2800
99
99
99
2727
2831
114
114
114
2721
2857
156
156
212
2751
2930

57
57
57
2728
2771
66
66
66
2724
2780
70
70
70
2721
2787
88
88
88
2718
2816
101
101
101
2712
2840
141
141
141
2739
2909

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

22

ASC Steel Deck

2W Composite Floor Deck


2W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/4 3 Hour Fire Rating Slab Weight: 75.6 psf
Gauge

22

21

20

19

18

16

No. of
Spans

60

66

70

76

80

86

Span
90

96

100

106

110

116

120

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

398
460
460
3227
3372
488
488
488
3236
3415
503
503
503
3342
3438
559
559
559
3272
3526
603
603
603
3298
3592
725
725
725
3371
3761

334
396
396
3206
3334
359
421
421
3212
3373
435
435
435
3217
3393
484
484
484
3242
3472
523
523
523
3264
3532
633
633
633
3329
3685

283
345
345
3188
3302
306
368
368
3192
3336
317
380
380
3196
3355
424
424
424
3216
3425
459
459
459
3235
3480
557
557
557
3293
3620

242
242
242
3173
3275
262
324
324
3175
3305
273
335
335
3177
3321
375
375
375
3194
3385
407
407
407
3210
3435
496
496
496
3262
3564

208
208
208
3160
3250
226
226
226
3159
3277
235
235
297
3161
3292
272
334
334
3174
3350
363
363
363
3189
3396
444
444
444
3234
3514

179
179
179
3148
3229
195
195
195
3146
3253
204
204
204
3147
3266
237
300
300
3157
3319
263
326
326
3169
3361
400
400
400
3210
3471

155
155
155
3137
3210
170
170
170
3134
3231
178
178
178
3134
3243
208
208
271
3142
3291
232
232
295
3152
3330
363
363
363
3189
3432

134
134
134
3128
3193
148
148
148
3123
3212
155
155
155
3123
3223
183
183
183
3128
3267
205
205
268
3137
3302
268
331
331
3170
3398

116
116
116
3119
3178
129
129
129
3113
3194
136
136
136
3112
3204
161
161
161
3116
3245
182
182
182
3123
3278
240
240
303
3152
3366

101
101
101
3111
3164
112
112
112
3105
3179
119
119
119
3103
3187
143
143
143
3105
3224
162
162
162
3111
3255
216
216
279
3137
3338

87
87
87
3104
3151
98
98
98
3097
3164
104
104
104
3095
3172
126
126
126
3095
3206
144
144
144
3100
3235
195
195
258
3122
3312

75
75
75
3098
3140
85
85
85
3089
3151
91
91
91
3087
3158
112
112
112
3085
3190
128
128
128
3089
3216
176
176
176
3109
3289

65
65
65
3092
3129
74
74
74
3083
3139
79
79
79
3080
3146
99
99
99
3077
3174
114
114
114
3080
3199
159
159
159
3098
3268

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 23

Preformed Metal Floor Deck

2W Superimposed Load with Studs at Supports


Allowable Superimposed Load (psf) for 2W Deck When 3/4 Diameter Studs are used at the Supporting Beams
Concrete
Slab & Type
Thickness

Studs at 10 OC
Gauge

60

70

80

22
400 320 240
4 1/2" LTWT
20
400 390 295
18
400 400 370
16
400 400 370
22
400 395 295
5 1/4" LTWT
20
400 400 360
18
400 400 400
16
400 400 400
22
400 400 385
6 1/2" LTWT
20
400 400 400
18
400 400 400
16
400 400 400
22
400 315 230
4 1/2" NWT
20
400 385 285
18
400 400 375
16
400 400 400
22
400 400 305
5 1/2" NWT
20
400 400 375
18
400 400 400
16
400 400 400
22
400 400 375
6 1/2" NWT
20
400 400 400
18
400 400 400
16
400 400 400
1. See 2W tables for shoring requirements.
2. SLAB thickness is the total slab thickness.

24

Studs at 30 OC

Span
90
100

110

120

60

70

80

Span
90

100

110

120

185
225
295
330
225
280
370
400
295
370
400
400
175
220
290
360
230
290
385
400
285
360
400
400

115
145
180
195
140
175
235
300
185
235
315
400
105
135
185
230
140
180
245
310
175
225
305
390

90
115
140
150
115
145
195
235
150
190
260
330
85
110
150
190
110
145
200
255
140
180
250
320

345
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400

245
280
390
400
305
335
400
400
400
400
400
400
290
290
390
400
380
380
400
400
400
400
400
400

180
195
280
360
260
230
340
400
345
295
400
400
215
215
275
360
280
280
340
400
350
400
390
400

16
135
205
270
200
170
245
325
260
330
290
400
165
160
200
265
215
265
235
325
265
325
260
375

125
155
155
205
155
195
175
240
200
255
200
290
125
160
140
195
165
205
285
235
205
250
355
255

100
125
115
155
120
155
210
180
155
200
280
205
100
125
175
145
130
165
230
290
160
195
280
360

80
105
140
120
95
125
175
130
120
160
230
290
80
105
140
180
100
130
185
235
125
155
225
295

145
180
235
265
175
220
295
360
235
290
390
400
135
170
230
285
180
225
305
385
225
280
380
400

ASC Steel Deck

2WF Composite Floor Deck


12

2WF - Allowable Reactions (plf)


Gauge

20/20

20/18

2-1/8

20/16

5
36
3 Welds

4 Welds

18/20

2WF also available in 24 coverage

2WF Section Properties

18/18

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20/20
20/18
20/16
18/20
18/18
18/16
16/16

3.60
4.18
4.55
4.15
4.67
5.10
5.79

0.674
0.741
0.797
0.901
0.928
1.003
1.196

0.416
0.423
0.429
0.601
0.611
0.621
0.771

0.435
0.451
0.463
0.600
0.592
0.608
0.749

18/16
16/16

1 1/2

286
628
286
628
286
628
615
1181
615
1181
615
1181
1054
1902

318
680
318
680
318
680
669
1258
669
1258
669
1258
1130
2003

Bearing Length
2
2 1/2

350
733
350
733
350
733
723
1334
723
1334
723
1334
1207
2104

382
804
382
804
382
804
777
1411
777
1411
777
1411
1283
2205

3 1/2

414
886
414
886
414
886
831
1493
831
1493
831
1493
1360
2306

446
968
446
968
446
968
884
1613
884
1613
884
1613
1436
2407

477
1051
477
1051
477
1051
938
1733
938
1733
938
1733
1512
2544

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

Slab Weight: 27.6 psf

No. of
Spans

60

66

70

76

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

289
289
289
1488
291
291
291
1571
292
292
292
1661
348
348
348
1543
350
350
350
1631
366
366
366
1723
425
425
425
1787

250
250
250
1447
252
252
252
1521
252
252
252
1602
302
302
302
1496
304
304
304
1575
318
318
318
1659
371
371
371
1717

218
218
218
1411
220
220
220
1478
220
220
220
1552
265
265
265
1455
267
267
267
1527
279
279
279
1603
327
327
327
1657

193
193
193
1380
194
194
194
1441
194
194
194
1508
234
234
234
1420
236
236
236
1485
247
247
247
1556
290
290
290
1604

171
171
171
1353
172
172
172
1408
173
173
173
1470
209
209
209
1389
211
211
211
1449
220
220
220
1514
260
260
260
1559

Effective January 2008

Span
86
90

153
153
153
1329
154
154
154
1380
155
155
155
1436
188
188
188
1362
189
189
189
1417
198
198
198
1477
235
235
235
1519

138
138
138
1308
139
139
139
1354
139
139
139
1406
170
170
170
1338
171
171
171
1388
179
179
179
1444
213
213
213
1483

96

100

106

110

116

120

125
125
125
1289
126
126
126
1331
126
126
126
1380
154
154
154
1316
156
156
156
1363
163
163
163
1414
194
194
194
1451

89
114
114
1272
89
115
115
1310
115
115
115
1355
141
141
141
1297
142
142
142
1340
148
148
148
1388
178
178
178
1422

79
104
104
1256
79
105
105
1292
79
105
105
1334
129
129
129
1279
130
130
130
1319
136
136
136
1364
164
164
164
1396

71
96
96
1242
71
96
96
1275
70
97
97
1314
119
119
119
1263
120
120
120
1300
125
125
125
1342
151
151
151
1372

63
63
88
1230
63
63
89
1259
63
63
89
1296
110
110
110
1249
111
111
111
1283
116
116
116
1322
140
140
140
1351

56
56
82
1218
57
57
82
1245
56
56
92
1279
102
102
102
1235
103
103
103
1267
108
108
108
1304
130
130
130
1331

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

Preformed Metal Deck 25

Preformed Metal Floor Deck

2WF Composite Floor Deck


2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4 1/2 1 Hour Fire Rating Slab Weight: 32.1 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

60

66

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

322
322
322
1646
324
324
324
1729
325
325
325
1819
386
386
386
1701
389
389
389
1789
404
404
404
1881
471
471
471
1945

279
279
279
1605
280
280
280
1679
281
281
281
1760
335
335
335
1654
338
338
338
1733
351
351
351
1817
411
411
411
1875

70

76

80

243
243
243
1569
245
245
245
1636
246
246
246
1710
294
294
294
1613
296
296
296
1685
308
308
308
1761
362
362
362
1814

215
215
215
1538
216
216
216
1599
216
216
216
1666
260
260
260
1578
262
262
262
1643
272
272
272
1714
322
322
322
1762

191
191
191
1511
192
192
192
1566
192
192
192
1628
232
232
232
1547
234
234
234
1607
243
243
243
1672
288
288
288
1717

Span
86
90

171
171
171
1487
172
172
172
1538
172
172
172
1594
209
209
209
1520
210
210
210
1575
218
218
218
1635
260
260
260
1677

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

26

154
154
154
1466
155
155
155
1512
155
155
155
1564
189
189
189
1496
190
190
190
1546
197
197
197
1602
236
236
236
1641

96

100

106

110

116

120

139
139
139
1447
140
140
140
1489
141
141
141
1538
172
172
172
1474
173
173
173
1521
180
180
180
1572
215
215
215
1609

98
127
127
1430
98
128
128
1468
98
128
128
1513
157
157
157
1455
158
158
158
1498
164
164
164
1546
197
197
197
1580

87
116
116
1414
88
117
117
1450
87
117
117
1492
144
144
144
1437
145
145
145
1477
150
150
150
1522
181
181
181
1554

78
78
107
1400
78
78
107
1433
78
78
108
1472
132
132
132
1421
133
133
133
1458
139
139
139
1500
167
167
167
1530

70
70
98
1387
70
70
99
1417
70
70
99
1454
122
122
122
1407
123
123
123
1441
128
128
128
1480
155
155
155
1509

62
62
62
1376
62
62
62
1403
62
62
62
1437
84
114
114
1393
85
114
114
1425
90
119
110
1462
144
144
144
1489

ASC Steel Deck

2WF Composite Floor Deck


2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/4 2 Hour Fire Rating Slab Weight: 38.9 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

60

66

70

76

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

375
375
375
1883
377
377
377
1966
378
378
378
2056
448
448
448
1938
451
451
451
2026
465
465
465
2118
544
544
544
2182

324
324
324
1842
325
325
325
1916
326
326
326
1997
389
389
389
1890
391
391
391
1970
404
404
404
2054
474
474
474
2112

283
283
283
1806
284
284
284
1873
285
285
285
1947
341
341
341
1850
343
343
343
1922
355
355
355
1998
418
418
418
2051

250
250
250
1775
251
251
251
1836
251
251
251
1903
302
302
302
1815
304
304
304
1880
314
314
314
1950
372
372
372
1999

222
222
222
1748
223
223
223
1803
223
223
223
1865
270
270
270
1784
271
271
271
1844
280
280
280
1909
333
333
333
1954

Span
86
90

199
199
199
1724
199
199
199
1774
200
200
200
1831
242
242
242
1757
244
244
244
1812
252
252
252
1872
300
300
300
1913

145
179
179
1703
180
180
180
1749
180
180
180
1801
219
219
219
1733
220
220
220
1783
228
228
228
1839
272
272
272
1878

96

100

106

110

116

120

128
162
162
1684
128
163
163
1726
128
163
163
1775
199
199
199
1711
200
200
200
1758
207
207
207
1809
248
248
248
1846

113
148
148
1667
114
148
148
1705
114
149
149
1750
182
182
182
1692
183
183
183
1735
189
189
189
1783
228
228
228
1817

101
101
135
1651
101
101
136
1687
101
101
136
1729
167
167
167
1674
168
168
168
1714
173
173
173
1759
209
209
209
1791

90
90
124
1637
90
90
125
1670
90
90
125
1709
154
154
154
1658
155
155
155
1695
160
160
160
1737
193
193
193
1767

80
80
80
1624
89
80
80
1654
80
80
80
1691
107
142
142
1644
108
143
143
1678
113
148
148
1717
179
179
179
1745

71
71
71
1613
72
72
72
1640
71
71
71
1674
97
97
132
1630
97
97
133
1662
102
102
137
1699
167
167
167
1726

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 27

Preformed Metal Floor Deck

2WF Composite Floor Deck


2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 Slab Weight: 36.4 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

60

66

70

76

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

289
289
289
1813
291
291
291
1896
292
292
292
1985
348
348
348
1867
350
350
350
1955
366
366
366
2048
425
425
425
2111

250
250
250
1771
252
252
252
1846
252
252
252
1927
302
302
302
1820
304
304
304
1899
318
318
318
1983
371
371
371
2041

218
218
218
1735
220
220
220
1803
220
220
220
1876
265
265
265
1779
267
267
267
1851
279
279
279
1928
327
327
327
1981

193
193
193
1705
194
194
194
1765
194
194
194
1833
234
234
234
1744
236
236
236
1810
247
247
247
1880
290
290
290
1929

171
171
171
1677
172
172
172
1733
173
173
173
1794
209
209
209
1713
211
211
211
1773
220
220
220
1838
260
260
260
1883

Span
86
90

153
153
153
1654
154
154
154
1704
155
155
155
1761
188
188
188
1686
189
189
189
1741
198
198
198
1801
235
235
235
1843

138
138
138
1632
139
139
139
1678
139
139
139
1731
170
170
170
1662
171
171
171
1713
179
179
179
1768
213
213
213
1807

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

28

96

100

106

110

116

120

93
125
125
1613
93
126
126
1656
93
126
126
1704
154
154
154
1641
156
156
156
1687
163
163
163
1739
194
194
194
1775

82
114
114
1596
82
115
115
1635
82
115
115
1680
141
141
141
1621
142
142
142
1664
148
148
148
1712
178
178
178
1746

72
72
104
1581
72
72
105
1616
72
105
105
1658
129
129
129
1604
130
130
130
1644
136
136
136
1688
164
164
164
1720

63
63
96
1567
63
63
96
1599
63
63
97
1638
119
119
119
1588
120
120
120
1625
125
125
125
1667
151
151
151
1697

56
56
56
1554
56
56
56
1584
56
56
56
1620
77
110
110
1573
78
111
111
1607
83
116
116
1647
140
140
140
1675

49
49
49
1542
49
49
49
1570
49
49
49
1604
69
69
102
1560
70
70
103
1592
75
108
108
1629
130
130
130
1655

ASC Steel Deck

2WF Composite Floor Deck


2WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 1/2 Slab Weight: 42.3 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

60

66

70

76

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

322
322
322
2052
324
324
324
2135
325
325
325
2225
386
386
386
2106
389
389
389
2194
404
404
404
2287
471
471
471
2350

279
279
279
2010
280
280
280
2085
281
281
281
2166
335
335
335
2059
338
338
338
2138
351
351
351
2222
411
411
411
2280

243
243
243
1975
245
245
245
2042
246
246
245
2115
294
294
294
2018
296
296
296
2090
308
308
308
2167
362
362
362
2220

215
215
215
1944
216
216
216
2004
216
216
216
2072
260
260
260
1983
262
262
262
2049
272
272
272
2119
322
322
322
2168

191
191
191
1917
192
192
192
1972
192
192
192
2034
232
232
232
1953
234
234
234
2012
243
243
243
2077
288
288
288
2122

Span
86
90

171
171
171
1893
172
172
172
1943
172
172
172
2000
209
209
209
1925
210
210
210
1980
218
218
218
2040
260
260
260
2082

117
154
154
1871
117
155
155
1917
117
155
155
1970
189
189
189
1901
190
190
190
1952
197
197
197
2007
236
236
236
2046

96

100

106

110

116

120

102
139
139
1852
103
140
140
1895
103
141
141
1943
172
172
172
1880
173
173
173
1926
180
180
180
1978
215
215
215
2014

90
90
127
1835
90
90
128
1874
90
128
128
1919
157
157
157
1860
158
158
158
1903
164
164
164
1951
197
197
197
1985

79
79
116
1820
79
79
117
1855
79
79
117
1897
144
144
144
1843
145
145
145
1883
150
150
150
1928
181
181
181
1959

69
69
69
1806
70
70
70
1838
70
70
70
1877
95
132
132
1827
95
133
133
1864
101
139
139
1906
167
167
167
1936

61
61
61
1793
61
61
61
1823
61
61
61
1859
85
85
122
1812
85
85
123
1847
90
128
128
1886
155
155
155
1914

54
54
54
1781
54
54
54
1809
54
54
54
1843
76
76
114
1799
76
76
114
1831
81
81
119
1868
144
144
144
1894

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 29

Preformed Metal Floor Deck

3W Composite Floor Deck

Allowable Reactions (plf)


Gauge
1

12

1 1/2

Bearing Length
2
2 1/2

3 1/2

155
175
195
215
235
255
275
402
441
488
550
611
673
734
21
232
259
286
313
340
367
395
539
586
630
704
778
852
927
20
275
306
337
367
398
429
459
615
666
717
787
867
948
1028
19
452
495
539
582
626
669
713
918
983
1049
1114 1208
1311 1414
18
602
655
707
760
813
866
919
1170
1246
1322
1398 1479
1598 1717
16
1042
1117
1193
1268 1344
1419 1495
1898
1998
2099
2200 2300
2401 2538
1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.
22

4-3/4

4-3/4
36
3
3W Section
Properties

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

22
21
20
19
18
16

1.68
1.83
2.04
2.29
2.70
3.36

0.769
0.881
0.938
1.126
1.260
1.582

0.433
0.511
0.550
0.692
0.780
0.976

0.471
0.540
0.574
0.694
0.777
0.975

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5
Gauge

22

21

20

19

18

16

30

Slab Weight: 32.0 psf

No. of
Spans

80

86

90

96

100

106

Span
110 116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

249
249
249
1281
1372
272
272
272
1281
1399
283
283
283
1283
1414
320
320
320
1296
1471
345
345
345
1310
1517
403
403
403
1356
1636

228
228
228
1269
1351
248
248
248
1267
1374
258
258
258
1268
1388
292
292
292
1279
1440
315
315
315
1291
1482
368
368
368
1332
1592

209
209
209
1259
1332
228
228
228
1255
1353
237
237
237
1256
1365
268
268
268
1263
1413
289
289
289
1274
1452
338
338
338
1310
1554

193
193
193
1249
1315
210
210
210
1245
1333
218
218
218
1244
1344
247
247
247
1250
1388
267
267
267
1259
1424
312
312
312
1291
1519

151
178
178
1241
1299
194
194
194
1235
1316
202
202
202
1234
1326
229
229
229
1237
1366
247
247
247
1245
1399
287
287
287
1274
1488

139
166
166
1233
1285
181
181
181
1226
1300
188
188
188
1225
1309
213
213
213
1226
1346
230
230
230
1232
1377
258
258
258
1258
1460

128
149
149
1226
1273
141
169
169
1218
1286
169
175
175
1216
1294
198
198
198
1216
1328
214
214
214
1221
1356
232
232
232
1244
1434

109
109
120
1214
1251
121
139
139
1204
1261
127
149
149
1201
1267
167
174
174
1198
1296
188
188
188
1201
1320
189
189
189
1219
1389

101
101
101
1208
1241
112
112
126
1198
1250
117
117
134
1195
1255
145
164
164
1191
1282
171
177
177
1192
1305
172
172
172
1208
1369

93
93
93
1203
1232
104
104
113
1193
1239
109
109
122
1189
1245
127
150
150
1183
1269
150
167
167
1184
1290
156
156
156
1198
1351

87
87
87
1199
1224
97
97
97
1187
1230
102
102
110
1183
1235
118
136
136
1177
1257
130
154
154
1177
1277
142
142
142
1189
1334

81
81
81
1195
1216
90
90
90
1182
1221
95
95
95
1178
1225
110
110
124
1171
1246
121
141
140
1170
1264
129
129
129
1180
1319

74
74
74
1191
1209
84
84
84
1178
1213
89
89
89
1173
1217
103
103
113
1165
1235
114
114
128
1164
1253
122
122
122
1172
1304

68
68
68
1187
1202
79
79
79
1174
1205
83
83
83
1169
1209
97
97
97
1159
1225
106
106
117
1158
1242
112
112
112
1164
1290

118
118
133
1220
1261
131
155
155
1211
1273
137
164
164
1208
1280
186
186
186
1207
1311
200
200
200
1211
1338
209
209
209
1231
1411

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

ASC Steel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)

Total Slab Thickness: 5 1/2


Gauge

22

21

20

19

18

16

1 Hour Fire Rating

Slab Weight:36.6 psf

No. of
Spans

80

86

90

96

100

106

Span
110
116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3

273
273
273
1439
1530
297
297
297
1439
1557
309
309
309
1441
1571
348
348
348
1454
1629
375
375
375
1468
1675
437
437
437
1514

249
249
249
1427
1509
271
271
271
1426
1532
282
282
282
1426
1546
318
318
318
1437
1598
343
343
343
1449
1640
399
399
399
1490

229
229
229
1417
1490
249
249
249
1413
1511
259
259
259
1414
1523
292
292
292
1421
1571
315
315
315
1432
1610
366
366
366
1468

211
211
211
1407
1473
230
230
230
1403
1491
239
239
239
1402
1502
269
269
269
1408
1546
290
290
290
1417
1582
338
338
338
1449

165
195
195
1399
1457
213
213
213
1393
1474
221
221
221
1392
1484
249
249
249
1395
1524
269
269
269
1403
1557
313
313
313
1432

151
181
181
1391
1443
195
198
198
1384
1453
205
205
205
1383
1467
232
232
232
1384
1504
250
250
250
1390
1535
291
291
291
1416

139
139
169
1384
1431
153
184
184
1376
1444
161
192
192
1374
1452
216
216
216
1374
1486
233
233
233
1379
1514
271
271
271
1402

118
118
118
1372
1409
131
131
159
1362
1419
137
137
168
1359
1425
179
190
190
1356
1454
204
204
204
1359
1478
238
238
238
1377

109
109
109
1366
1399
121
121
143
1356
1408
127
127
154
1353
1413
149
178
178
1349
1440
184
192
192
1350
1463
224
224
224
1366

101
101
101
1361
1390
113
113
113
1351
1397
118
118
139
1347
1403
137
168
168
1341
1427
150
181
181
1342
1448
211
211
211
1356

94
94
94
1357
1382
105
105
105
1345
1388
110
110
110
1341
1393
128
128
156
1335
1415
140
171
171
1335
1435
199
199
199
1347

87
87
87
1353
1374
97
97
97
1340
1379
102
102
102
1336
1383
119
119
142
1329
1404
131
131
162
1328
1422
157
189
189
1338

81
81
81
1349
1367
91
91
91
1336
1371
96
96
96
1331
1375
111
111
111
1323
1393
122
122
148
1322
1411
147
179
179
1330

76
76
76
1345
1360
85
85
85
1332
1363
89
89
89
1327
1366
104
104
104
1317
1383
115
115
135
1316
1400
138
170
170
1322

q4

1794

1750

1712

1677

1646

1618

1592

128
128
152
1378
1419
142
172
172
1369
1431
148
179
179
1366
1438
202
202
202
1365
1469
218
218
218
1369
1496
253
253
253
1389
1569

1547

1527

1509

1492

1477

1462

1448

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 31

Preformed Metal Floor Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)

Total Slab Thickness: 6 1/4


Gauge

22

21

20

19

18

16

2 Hour Fire Rating

Slab Weight:43.6 psf

No. of
Spans

80

86

90

96

100

106

Span
110 116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

311
311
311
1676
1767
338
338
338
1676
1794
352
352
352
1678
1808
396
396
396
1691
1866
426
426
426
1705
1912
494
494
494
1751
2031

284
284
284
1664
1746
309
309
309
1662
1769
321
321
321
1663
1783
361
361
361
1674
1835
389
389
389
1686
1877
451
451
451
1727
1987

261
261
261
1654
1726
284
284
284
1650
1748
295
295
295
1650
1760
332
332
332
1658
1808
357
357
357
1669
1847
414
414
414
1705
1949

205
241
241
1644
1709
262
262
262
1640
1728
272
272
272
1639
1739
306
306
306
1645
1783
329
329
329
1654
1819
382
382
382
1686
1914

187
223
223
1636
1694
206
242
242
1630
1711
252
252
252
1629
1721
283
283
283
1632
1761
305
305
305
1640
1794
353
353
353
1669
1883

171
171
207
1628
1680
189
225
225
1621
1695
198
234
234
1620
1704
263
263
263
1621
1741
283
283
283
1627
1772
328
328
328
1653
1885

157
157
193
1621
1668
174
210
210
1613
1681
182
218
218
1611
1689
245
245
245
1611
1723
264
264
264
1616
1751
306
306
306
1639
1829

133
133
133
1609
1646
148
148
184
1599
1656
155
155
191
1596
1662
179
215
215
1593
1691
232
232
232
1596
1715
269
269
269
1614
1784

123
123
123
1603
1636
137
137
137
1593
1644
144
144
180
1590
1650
166
166
203
1586
1677
181
218
218
1587
1700
253
253
253
1603
1764

114
114
114
1598
1627
127
127
127
1587
1634
133
133
133
1584
1639
154
154
191
1578
1664
169
206
206
1579
1685
238
238
238
1593
1746

106
106
106
1594
1619
118
118
118
1582
1625
124
124
124
1578
1629
144
144
181
1572
1652
157
157
194
1572
1672
188
225
225
1584
1729

98
98
98
1589
1611
110
110
110
1577
1616
115
115
115
1573
1620
134
134
134
1565
1641
147
147
184
1565
1659
176
213
213
1575
1714

91
91
91
1586
1604
102
102
102
1573
1608
108
108
108
1568
1612
125
125
125
1560
1630
137
137
137
1559
1648
165
202
202
1567
1699

85
85
85
1582
1597
95
95
95
1569
1600
100
100
100
1564
1603
117
117
117
1554
1620
129
129
129
1553
1637
155
155
192
1559
1685

145
145
145
1615
1656
160
160
196
1606
1668
168
168
204
1603
1675
227
230
230
1602
1706
247
247
247
1606
1733
287
287
287
1626
1806

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

32

ASC Steel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 7 3/16
Gauge

22

21

20

19

18

16

3 Hour Fire Rating

Slab Weight:52.1 psf

No. of
Spans

80

86

90

96

100

106

Span
110 116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

363
363
363
1972
2063
394
394
394
1972
2090
409
409
409
1974
2105
460
460
460
1987
2163
494
494
494
2001
2208
571
571
571
2047
2327

288
331
331
1960
2042
360
360
360
1958
2065
373
373
373
1959
2079
420
420
429
1970
2132
451
451
451
1982
2174
522
522
522
2023
2284

261
304
304
1950
2023
330
330
330
1946
2044
343
343
343
1947
2056
385
385
385
1954
2104
414
414
414
1965
2143
479
479
479
2001
2245

237
280
280
1940
2006
261
304
304
1936
2024
316
316
316
1935
2035
355
355
355
1941
2079
382
382
382
1950
2115
442
442
442
1982
2210

217
217
259
1932
1990
239
282
282
1926
2007
250
293
293
1925
2017
329
329
329
1928
2057
353
353
353
1936
2090
409
409
409
1965
2179

198
198
241
1924
1976
219
219
262
1917
1991
229
272
272
1916
2000
306
306
306
1917
2037
328
328
328
1923
2068
380
380
380
1949
2151

182
182
182
1917
1964
201
201
244
1909
1977
210
210
254
1907
1985
285
285
285
1907
2019
306
306
306
1912
2047
354
354
354
1935
2125

154
154
154
1905
1942
171
171
171
1895
1952
179
179
179
1893
1958
207
207
250
1890
1987
225
269
269
1892
2012
311
311
311
1910
2080

143
143
143
1900
1932
159
159
159
1889
1941
166
166
166
1886
1947
192
192
235
1882
1973
209
209
253
1884
1996
293
293
293
1899
2061

132
132
132
1895
1923
147
147
147
1884
1930
154
154
154
1880
1936
178
178
178
1875
1960
195
195
238
1876
1981
232
276
276
1889
2040

122
122
122
1890
1915
136
136
136
1878
1921
143
143
143
1875
1926
166
166
166
1868
1948
182
182
225
1868
1968
216
261
261
1880
2025

114
114
114
1886
1907
127
127
127
1874
1912
133
133
133
1869
1916
155
155
155
1862
1937
170
170
170
1861
1955
202
202
247
1871
2010

105
105
105
1882
1900
118
118
118
1869
1904
124
124
124
1865
1908
145
145
145
1856
1926
159
159
159
1855
1944
190
190
234
1863
1995

98
98
98
1878
1893
110
110
110
1865
1897
116
116
116
1860
1900
135
135
135
1851
1917
149
149
149
1849
1933
178
178
178
1855
1982

167
167
167
1911
1952
185
185
228
1902
1964
194
194
237
1900
1971
223
267
267
1898
2002
287
287
287
1902
2029
332
332
332
1922
2102

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 33

Preformed Metal Floor Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 Slab Weight: 42.3 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

90

96

100

106

Span
110 116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

249
249
249
1605
1696
272
272
272
1605
1723
283
283
283
1607
1738
320
320
320
1620
1796
345
345
345
1635
1842
403
403
403
1680
1960

228
228
228
1594
1675
248
248
248
1592
1699
258
258
258
1593
1712
292
292
292
1603
1765
315
315
315
1615
1807
368
368
368
1656
1917

209
209
209
1583
1656
228
228
228
1580
1677
237
237
237
1580
1689
268
268
268
1588
1737
289
289
289
1598
1776
338
338
338
1635
1878

158
193
193
1574
1639
210
210
210
1569
1658
218
218
218
1569
1669
247
247
247
1574
1713
267
267
267
1583
1748
312
312
312
1616
1843

143
178
178
1565
1624
159
194
194
1559
1640
197
202
202
1558
1650
229
229
229
1562
1690
247
247
247
1569
1724
289
289
289
1598
1812

131
131
159
1557
1610
145
181
181
1551
1624
153
188
188
1549
1633
213
213
213
1551
1670
230
230
230
1557
1701
260
260
260
1583
1784

120
120
141
1550
1597
133
165
165
1543
1610
140
175
175
1541
1618
189
198
198
1541
1652
214
214
214
1545
1681
233
233
233
1568
1758

101
101
101
1538
1575
113
113
131
1529
1585
118
118
141
1526
1592
138
174
174
1523
1620
165
188
188
1526
1645
189
189
189
1543
1714

92
92
92
1533
1565
104
104
104
1523
1574
109
109
126
1519
1580
128
128
156
1515
1606
141
177
177
1517
1629
170
170
170
1533
1694

85
85
85
1528
1556
96
96
96
1517
1564
101
101
101
1513
1569
119
119
141
1508
1593
131
160
160
1509
1615
153
153
153
1522
1676

78
78
78
1523
1548
89
89
89
1512
1554
93
93
93
1508
1559
110
110
127
1501
1581
121
121
145
1501
1601
143
141
141
1513
1659

72
72
72
1519
1540
82
82
82
1507
1546
87
87
87
1503
1550
102
102
102
1495
1570
113
113
131
1494
1589
131
128
128
1504
1643

67
67
67
1515
1533
76
76
76
1502
1537
80
80
80
1498
1541
95
95
95
1489
1560
105
105
105
1488
1577
119
116
116
1496
1628

60
60
60
1511
1527
70
70
70
1498
1530
74
74
74
1493
1533
89
89
89
1484
1550
98
98
98
1482
1566
109
109
105
1489
1615

110
110
110
1544
1586
122
122
147
1535
1597
129
129
157
1533
1604
160
186
186
1531
1635
192
200
200
1535
1662
209
209
209
1555
1735

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

34

ASC Steel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 Slab Weight: 48.3 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

90

96

100

106

Span
110 116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

273
273
273
1845
1936
297
297
297
1844
1962
309
309
309
1846
1977
348
348
348
1859
2035
375
375
375
1874
2081
437
437
439
1919
2199

249
249
249
1833
1914
271
271
271
1831
1938
282
282
282
1832
1951
318
318
318
1842
2004
343
343
343
1854
2046
399
399
399
1895
2156

189
229
229
1822
1895
249
249
249
1819
1916
259
259
259
1819
1928
292
292
292
1827
1976
315
315
315
1837
2015
366
366
366
1874
2117

171
211
211
1813
1878
229
229
229
1808
1897
239
239
239
1808
1908
269
269
269
1813
1952
290
290
290
1822
1988
338
338
338
1855
2083

155
155
195
1804
1863
173
213
213
1798
1879
181
221
221
1797
1889
249
249
249
1801
1930
269
269
269
1808
1963
313
313
313
1837
2051

142
142
181
1797
1849
157
198
198
1790
1864
165
205
205
1788
1872
232
232
232
1790
1910
250
250
250
1796
1940
291
291
291
1822
2023

129
129
129
1790
1836
144
144
184
1782
1849
151
151
192
1780
1857
200
216
216
1780
1891
233
233
233
1785
1920
271
271
271
1807
1998

109
109
109
1777
1814
122
122
122
1768
1824
128
128
161
1765
1831
149
149
190
1762
1859
172
204
204
1765
1884
238
238
238
1783
1953

100
100
100
1772
1804
112
112
112
1762
1813
118
118
118
1755
1819
138
138
178
1754
1845
151
192
192
1756
1868
217
224
224
1772
1933

92
92
92
1767
1796
103
103
103
1756
1803
109
109
109
1752
1808
128
128
162
1747
1832
140
140
181
1748
1854
169
211
211
1762
1915

84
84
84
1762
1787
95
95
95
1751
1793
101
101
101
1747
1798
118
118
118
1740
1820
130
130
168
1741
1840
158
199
199
1752
1898

78
79
78
1758
1780
88
88
88
1746
1785
93
93
93
1742
1789
110
110
110
1734
1809
121
121
121
1734
1828
147
147
189
1743
1882

72
72
72
1754
1772
81
81
81
1741
1777
86
86
86
1737
1780
102
102
102
1728
1799
113
113
113
1727
1816
138
138
179
1735
1868

66
66
66
1750
1766
75
75
75
1737
1769
80
80
80
1732
1772
95
95
95
1723
1789
105
105
105
1721
1805
129
129
164
1728
1854

118
118
118
1783
1825
132
132
168
1774
1836
139
139
179
1772
1843
162
202
202
1770
1875
204
218
218
1774
1901
253
253
253
1794
1974

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 35

Preformed Metal Floor Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2 1 Hour Fire Rating Slab Weight: 60.5 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

325
325
325
2323
2414
353
353
353
2323
2440
367
367
367
2324
2455
412
412
412
2337
2513
443
443
443
2352
2559
514
514
514
2398
2678

247
296
295
2311
2392
322
322
322
2309
2416
335
335
335
2310
2429
377
377
377
2320
2482
405
405
405
2333
2524
469
469
469
2373
2634

223
272
272
2300
2373
246
296
296
2297
2394
307
307
307
2297
2406
346
346
346
2305
2455
372
372
372
2316
2493
431
431
431
2352
2595

202
202
251
2291
2356
223
273
273
2286
2375
234
283
283
2286
2386
319
319
319
2291
2430
343
343
343
2300
2466
397
397
397
2333
2561

183
183
183
2282
2341
203
203
253
2277
2357
213
262
262
2276
2367
295
295
295
2279
2408
317
317
317
2286
2441
368
368
368
2315
2530

166
166
166
2275
2327
185
185
235
2268
2342
194
194
244
2266
2351
224
274
274
2268
2388
295
295
295
2274
2418
342
342
342
2300
2501

152
152
152
2268
2314
169
169
169
2260
2327
178
178
227
2258
2335
206
256
256
2258
2369
263
275
275
2263
2398
319
319
319
2286
2476

139
139
139
2261
2303
155
155
155
2253
2314
163
163
163
2250
2322
189
189
239
2249
2353
207
257
257
2252
2379
298
298
298
2273
2452

127
127
127
2255
2292
142
142
142
2246
2302
150
150
150
2243
2309
174
174
224
2240
2337
191
191
241
2243
2362
278
278
278
2261
2431

117
117
117
2250
2283
131
131
131
2240
2291
138
138
138
2237
2297
161
161
161
2232
2323
177
177
227
2234
2346
212
263
263
2250
2411

107
107
107
2245
2274
121
121
121
2234
2281
127
127
127
2231
2286
149
149
149
2225
2310
164
164
164
2226
2332
197
248
248
2240
2393

98
98
98
2241
2265
111
111
111
2229
2272
117
117
117
2225
2276
138
138
138
2218
2298
152
152
152
2219
2318
183
183
234
2230
2376

91
91
91
2236
2258
103
103
103
2224
2263
108
108
108
2220
2267
128
128
128
2212
2287
141
141
141
2212
2306
171
171
222
2222
2360

83
83
83
2232
2251
95
95
95
2220
2255
100
100
100
2215
2258
119
119
119
2206
2277
131
131
131
2205
2294
159
159
159
2214
2346

77
77
77
2229
2244
87
87
87
2215
2247
93
93
93
2211
2250
110
110
110
2201
2267
122
122
122
2199
2284
149
149
149
2206
2332

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

36

ASC Steel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1 1/2 Hour Fire Rating Slab Weight: 66.4 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

298
352
352
2562
2653
383
383
383
2562
2679
397
397
397
2563
2694
447
447
447
2577
2752
480
480
480
2591
2798
556
556
556
2637
2917

267
321
321
2550
2631
349
349
349
2548
2655
363
383
363
2549
2668
408
408
408
2559
2721
438
438
438
2572
2763
507
507
507
2613
2873

241
241
295
2539
2612
266
321
321
2536
2633
278
333
333
2536
2645
374
374
374
2544
2694
402
402
402
2555
2732
466
466
466
2591
2834

218
218
272
2530
2595
241
296
296
2525
2614
252
307
307
2525
2625
345
345
345
2530
2669
371
371
371
2539
2705
429
429
429
2572
2800

198
198
198
2521
2580
219
219
274
2516
2597
230
230
284
2516
2606
320
320
320
2518
2647
343
343
343
2526
2680
397
397
397
2555
2769

180
180
180
2514
2566
200
200
254
2507
2581
210
210
264
2505
2590
242
297
297
2507
2627
319
319
319
2513
2657
369
369
369
2539
2740

164
164
164
2507
2554
183
183
183
2499
2566
192
192
192
2497
2574
222
222
277
2497
2609
243
298
298
2502
2637
345
345
345
2525
2715

150
150
150
2500
2542
167
167
167
2492
2553
176
176
176
2489
2561
204
204
259
2488
2592
223
223
278
2491
2618
322
322
322
2512
2691

137
137
137
2495
2531
154
154
154
2485
2541
162
162
162
2482
2548
188
188
188
2479
2577
206
206
261
2482
2601
247
302
302
2500
2670

126
126
126
2489
2522
141
141
141
2479
2530
149
149
149
2476
2536
174
174
174
2471
2563
191
191
246
2473
2586
229
284
284
2489
2650

115
115
115
2484
2513
130
130
130
2473
2520
137
137
137
2470
2525
161
161
161
2464
2550
176
176
176
2465
2571
212
212
268
2479
2632

106
106
106
2480
2504
120
120
120
2468
2511
126
126
120
2464
2515
149
149
149
2457
2538
164
164
164
2458
2558
198
198
253
2469
2615

97
97
97
2475
2497
110
110
110
2463
2502
117
117
117
2459
2506
138
138
138
2451
2526
152
152
152
2451
2545
184
184
184
2461
2599

90
90
90
2471
2490
102
102
102
2459
2494
108
108
108
2454
2497
128
128
128
2446
2516
141
141
141
2444
2533
172
172
172
2453
2585

82
82
82
2468
2483
94
94
94
2454
2486
100
100
100
2450
2489
119
119
119
2440
2506
132
132
132
2438
2523
160
160
160
2445
2571

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 37

Preformed Metal Floor Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/2 2 Hour Fire Rating Slab Weight: 72.5 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

321
380
380
2801
2892
413
413
413
2801
2919
429
429
429
2802
2933
482
482
482
2816
2991
517
517
517
2830
3037
598
598
598
2876
3156

288
347
347
2789
2870
318
377
377
2787
2894
391
391
391
2788
2908
440
440
440
2798
2960
473
473
473
2811
3002
546
546
546
2852
3112

260
260
319
2778
2851
287
346
346
2775
2872
300
359
359
2775
2885
404
404
404
2783
2933
434
434
434
2794
2971
502
502
502
2830
3074

235
235
235
2769
2834
260
260
319
2764
2853
272
331
331
2764
2864
372
372
372
2769
2908
400
400
400
2778
2944
462
462
462
2811
3039

213
213
213
2761
2819
236
236
295
2755
2836
247
247
307
2754
2846
285
345
345
2757
2886
370
370
370
2765
2919
428
428
428
2794
3008

194
194
194
2753
2805
215
215
215
2746
2820
226
226
285
2744
2829
261
261
320
2746
2866
284
344
344
2752
2897
398
398
398
2778
2979

177
177
177
2746
2793
197
197
197
2738
2806
206
206
206
2736
2814
239
239
299
2736
2848
261
261
321
2741
2876
371
371
371
2764
2954

161
161
161
2739
2781
180
180
180
2731
2792
189
189
189
2728
2800
220
220
279
2727
2831
240
240
300
2731
2857
347
347
347
2751
2930

148
148
148
2734
2771
165
165
165
2724
2780
174
174
174
2721
2787
202
202
202
2718
2816
222
222
282
2721
2840
265
326
326
2739
2909

135
135
135
2728
2761
152
152
152
2718
2769
160
160
160
2715
2775
187
187
187
2710
2802
205
205
205
2712
2825
246
246
306
2728
2889

124
124
124
2723
2752
140
140
140
2712
2759
147
147
147
2709
2764
173
173
173
2703
2789
190
190
190
2704
2810
228
228
289
2718
2871

114
114
114
2719
2744
129
129
129
2707
2750
136
136
136
2703
2754
160
160
160
2697
2777
176
176
176
2697
2797
212
212
212
2709
2854

105
105
105
2714
2736
119
119
119
2702
2741
126
126
126
2698
2745
148
148
148
2690
2765
163
163
163
2690
2784
198
198
198
2700
2838

96
96
96
2710
2729
110
110
110
2698
2733
116
116
116
2693
2736
137
137
137
2685
2755
152
152
152
2683
2773
185
185
185
2692
2824

88
88
88
2707
2722
101
101
101
2694
2725
107
107
107
2689
2728
128
128
128
2679
2745
141
141
141
2677
2762
172
172
172
2684
2810

1. In shaded area, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

38

ASC Steel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 8 1/4 3 Hour Fire Rating Slab Weight: 81.6 psf
Gauge

22

21

20

19

18

16

No. of
Spans

80

86

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

357
423
423
3160
3250
393
459
459
3159
3277
477
477
477
3161
3292
536
536
536
3174
3350
575
575
575
3189
3396
665
665
665
3234
3514

320
320
386
3148
3229
353
419
419
3146
3253
369
435
435
3147
3266
489
489
489
3157
3319
525
525
525
3169
3361
607
607
607
3210
3471

90

288
288
288
3137
3210
319
319
385
3134
3231
333
400
400
3134
3243
449
449
449
3142
3291
482
482
482
3152
3330
557
557
557
3189
3432

96

100

106

Span
110

116

120

126

130

136

140

146

150

261
261
261
3128
3193
289
289
355
3123
3212
302
302
368
3123
3223
347
414
414
3128
3267
445
445
445
3137
3302
514
514
514
3170
3398

236
236
236
3119
3178
262
262
262
3113
3194
275
275
341
3112
3204
316
316
383
3116
3245
345
412
412
3123
3278
476
476
476
3152
3366

215
215
215
3111
3164
239
239
239
3105
3179
251
251
251
3103
3187
289
289
356
3105
3224
315
383
383
3111
3255
442
442
442
3137
3338

196
196
196
3104
3151
218
218
218
3097
3164
229
229
229
3095
3172
265
265
332
3095
3206
290
290
357
3100
3235
412
412
412
3122
3312

179
179
179
3098
3140
200
200
200
3089
3151
210
210
210
3087
3158
244
244
244
3085
3190
267
267
334
3089
3216
318
386
386
3109
3289

164
164
164
3092
3129
183
183
183
3083
3139
193
193
193
3080
3146
225
225
225
3077
3174
246
246
246
3080
3199
294
294
362
3098
3268

150
150
150
3087
3119
169
169
169
3077
3128
177
177
177
3073
3134
207
207
207
3069
3160
227
227
227
3071
3183
272
272
340
3087
3248

138
138
138
3082
3111
155
155
155
3071
3118
163
163
163
3067
3123
192
192
192
3062
3147
210
210
210
3063
3169
253
253
253
3076
3230

126
126
126
3077
3102
143
143
143
3066
3108
151
151
151
3062
3113
177
177
177
3055
3135
195
195
195
3055
3155
235
235
235
3067
3213

116
116
116
3073
3095
132
132
132
3061
3100
139
139
139
3057
3104
164
164
164
3049
3124
181
181
181
3049
3143
219
219
219
3058
3197

107
107
107
3069
3087
121
121
121
3056
3091
128
128
128
3052
3095
152
152
152
3043
3114
168
168
168
3042
3131
204
204
204
3050
3182

98
98
98
3065
3081
112
112
112
3052
3084
119
119
119
3047
3087
141
141
141
3038
3104
157
157
157
3036
3120
191
191
191
3043
3169

1. In shaded area, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 39

Preformed Metal Floor Deck

3WF Composite Floor Deck


12

4-3/4

Allowable Reactions (plf)


Gauge

20/20

20/18

4-3/4
36

20/16

4 Welds
3 Welds
Also available in 24 coverage

18/20

3WF-Section Properties
Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20/20
20/18
20/16
18/20
18/18
18/16
16/16

3.44
3.96
4.45
4.10
4.59
5.11
5.73

1.328
1.469
1.585
1.662
1.832
1.984
2.350

0.623
0.634
0.646
0.870
0.885
0.899
1.113

0.623
0.646
0.666
0.832
0.855
0.873
1.080

18/18
18/16
16/16

1 1/2

275
615
275
615
275
615
602
1170
502
1170
602
1170
1042
1898

306
666
306
666
306
666
655
1246
655
1246
655
1246
1117
1998

Bearing Length
2
2 1/2

337
717
337
717
337
717
707
1322
707
1322
707
1322
1193
2099

367
787
367
787
367
787
760
1398
760
1398
760
1398
1268
2200

3 1/2

398
867
398
867
398
867
813
1479
813
1479
813
1479
1344
2300

429
948
429
948
429
948
866
1598
866
1598
866
1598
1419
2401

459
1028
459
1028
459
1028
919
1717
919
1717
919
1717
1495
2538

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 Slab Weight: 32.0 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

307
307
307
1353
309
309
309
1408
295
295
295
1470
371
371
371
1389
363
363
363
1449
350
350
350
1514
399
399
399
1559

280
280
280
1329
282
282
282
1380
270
270
270
1436
339
339
339
1362
331
331
331
1417
319
319
319
1477
364
364
364
1519

257
257
257
1308
259
259
259
1354
247
247
247
1406
311
311
311
1338
304
304
304
1388
293
293
293
1444
334
334
334
1483

237
237
237
1289
239
239
239
1331
228
228
228
1380
287
287
287
1316
280
280
280
1363
270
270
270
1414
308
308
308
1451

220
220
220
1272
221
221
221
1310
211
211
211
1355
265
265
265
1297
260
260
260
1340
250
250
250
1388
285
285
285
1422

204
204
204
1256
206
206
206
1292
196
196
196
1334
247
247
247
1279
241
241
241
1319
233
233
233
1364
265
265
265
1396

191
191
191
1242
192
192
192
1275
183
183
183
1314
230
230
230
1263
225
225
225
1300
217
217
217
1342
247
247
247
1372

178
178
178
1230
179
179
179
1259
171
171
171
1296
215
215
215
1249
210
210
210
1283
203
203
203
1322
231
231
231
1351

167
167
167
1218
168
168
168
1245
161
161
161
1279
202
202
202
1235
197
197
197
1267
190
190
190
1304
217
217
217
1331

121
151
151
1207
121
158
158
1232
122
151
151
1264
190
190
190
1223
186
186
186
1253
179
179
179
1287
204
204
204
1312

112
112
148
1197
112
149
149
1220
113
143
143
1250
179
179
179
1212
175
175
175
1239
169
169
169
1272
193
193
193
1296

103
103
140
1188
104
104
141
1209
105
105
135
1237
169
169
169
1201
165
165
165
1227
160
160
160
1258
182
182
182
1280

96
96
133
1179
97
97
134
1199
98
98
128
1225
160
160
160
1191
157
157
157
1215
151
151
151
1244
172
172
172
1266

89
89
89
1171
90
90
90
1189
92
92
121
1213
123
152
152
1182
149
149
149
1205
143
143
143
1232
163
163
163
1252

83
83
83
1164
83
83
83
1180
86
86
86
1203
116
116
145
1174
112
112
141
1195
106
106
136
1220
155
155
155
1240

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

40

ASC Steel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/2 1 Hour Fire Rating Slab Weight: 36.6 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

334
334
334
1511
337
337
337
1566
338
338
338
1628
402
402
402
1547
406
406
406
1607
408
408
408
1672
473
473
473
1717

305
305
305
1487
307
307
307
1538
309
309
309
1594
367
367
367
1520
371
371
371
1575
373
373
373
1635
432
432
432
1677

280
280
280
1466
282
282
282
1512
284
284
284
1564
337
337
337
1496
340
340
340
1546
342
342
342
1602
396
396
396
1641

258
258
258
1447
260
260
280
1489
262
262
262
1538
311
311
311
1474
314
314
314
1521
316
316
316
1572
365
365
365
1609

239
239
239
1430
241
241
241
1468
242
242
242
1513
288
288
288
1455
290
290
290
1498
292
292
292
1546
338
338
338
1580

222
222
222
1414
224
224
224
1450
225
225
225
1492
267
267
267
1437
270
270
270
1477
272
272
272
1522
314
314
314
1554

207
207
207
1400
209
209
209
1433
210
210
210
1472
249
249
249
1421
252
252
252
1458
253
253
253
1500
293
293
293
1530

194
194
194
1387
195
195
195
1417
196
196
196
1454
233
233
233
1407
235
235
235
1441
237
237
237
1480
274
274
274
1509

150
182
182
1376
157
183
183
1403
151
184
184
1437
219
219
219
1393
221
221
221
1425
222
222
222
1462
257
257
257
1489

139
139
171
1365
140
172
172
1390
140
173
173
1422
206
206
206
1381
208
208
208
1411
209
209
209
1445
242
242
242
1470

129
129
161
1355
130
130
163
1378
130
130
163
1408
194
194
194
1370
196
196
196
1397
197
197
197
1430
228
228
228
1454

120
120
152
1346
121
121
154
1367
121
121
154
1395
183
183
183
1359
185
185
185
1385
186
186
186
1416
216
216
216
1438

112
112
112
1337
113
113
113
1357
113
113
146
1383
174
174
174
1349
175
175
175
1373
176
176
176
1402
204
204
204
1424

105
105
105
1329
106
106
106
1347
106
106
106
1371
132
132
155
1340
133
133
166
1363
134
134
167
1390
194
194
194
1410

98
98
98
1322
99
99
99
1338
99
99
99
1361
124
124
124
1332
125
125
158
1353
126
126
159
1378
150
184
184
1397

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 41

Preformed Metal Floor Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 1/4 2 Hour Fire Rating Slab Weight: 43.6 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

378
378
378
1748
380
380
380
1803
382
382
382
1865
453
453
453
1784
457
457
457
1844
460
460
460
1909
530
530
530
1954

86

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

345
345
345
1724
347
347
347
1774
349
349
349
1831
413
413
413
1757
417
417
417
1812
420
420
420
1872
484
484
484
1913

316
316
316
1703
319
319
319
1749
320
320
320
1801
379
379
379
1733
383
383
383
1783
385
385
385
1839
444
444
444
1878

292
292
292
1684
294
294
294
1726
295
295
295
1775
350
350
350
1711
353
353
353
1758
355
355
355
1809
410
410
410
1846

270
270
270
1667
272
272
272
1705
273
273
273
1750
324
324
324
1692
327
327
327
1735
329
329
329
1783
379
379
379
1817

251
251
251
1651
253
253
253
1687
254
254
254
1729
301
301
301
1674
304
304
304
1714
306
306
306
1759
352
352
352
1791

234
234
234
1637
236
236
236
1670
237
237
237
1709
281
281
281
1658
283
283
283
1645
285
285
285
1737
329
329
329
1767

181
219
219
1624
183
221
221
1654
183
222
222
1691
263
263
263
1644
265
265
265
1678
267
267
267
1717
308
308
308
1745

168
168
206
1613
169
169
207
1640
170
208
208
1674
246
246
246
1630
249
249
249
1662
250
250
250
1699
288
288
288
1726

156
156
193
1602
157
157
195
1627
157
157
196
1659
232
232
232
1618
234
234
234
1648
235
235
235
1682
271
271
271
1707

145
145
182
1592
146
146
184
1615
146
146
184
1645
219
219
219
1606
221
221
221
1634
222
222
222
1667
256
256
256
1691

135
135
135
1583
136
136
136
1604
136
136
136
1632
169
169
207
1596
170
208
208
1622
171
210
210
1653
242
242
242
1675

126
126
126
1574
126
126
126
1594
127
127
127
1619
158
158
158
1586
159
159
197
1610
160
160
199
1639
229
229
229
1661

117
117
117
1566
118
118
118
1584
118
118
118
1608
147
147
147
1577
149
149
187
1600
149
149
188
1627
178
217
217
1647

110
110
110
1559
110
110
110
1575
110
110
110
1598
138
138
138
1569
139
139
178
1590
140
140
179
1615
167
206
206
1634

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

42

ASC Steel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 Slab Weight: 42.3 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

307
307
307
1677
309
309
309
1733
295
295
295
1794
371
371
371
1713
363
363
363
1773
350
350
350
1838
399
399
399
1883

86

280
280
280
1654
282
282
282
1704
270
270
270
1761
339
339
339
1686
331
331
331
1741
319
319
319
1801
364
364
364
1843

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

257
257
257
1632
259
259
259
1678
247
247
247
1731
311
311
311
1662
304
304
304
1713
293
293
293
1768
334
334
334
1807

237
237
237
1613
239
239
239
1656
228
228
228
1704
287
287
287
1641
280
280
280
1687
270
270
270
1739
308
308
308
1775

220
220
220
1596
221
221
221
1635
211
211
211
1680
265
265
265
1621
260
260
260
1664
250
250
250
1712
285
285
285
1746

204
204
204
1581
206
206
206
1616
196
196
196
1658
247
247
247
1604
241
241
241
1644
233
233
233
1688
265
265
265
1720

191
191
191
1567
192
192
192
1599
183
183
183
1638
230
230
230
1588
225
225
225
1625
217
217
217
1667
247
247
247
1697

142
178
178
1554
142
179
179
1584
134
171
171
1620
215
215
215
1573
210
210
210
1607
203
203
203
1647
231
231
231
1675

131
131
167
1542
131
131
168
1570
123
161
161
1604
202
202
202
1560
197
197
197
1592
190
190
190
1629
217
217
217
1655

121
121
157
1531
121
121
158
1557
114
114
151
1588
190
190
190
1547
186
186
186
1577
179
179
179
1612
204
204
204
1637

112
112
148
1521
112
112
149
1545
105
105
143
1574
179
179
179
1536
175
175
175
1564
169
169
169
1596
193
193
193
1620

103
103
103
1512
104
104
104
1533
97
97
97
1561
132
169
169
1525
128
165
165
1551
122
160
160
1582
182
182
182
1604

96
96
96
1504
97
97
97
1523
90
90
90
1549
123
123
123
1516
119
119
157
1540
113
113
151
1569
172
172
172
1590

89
89
89
1496
90
90
90
1513
83
83
83
1538
115
115
115
1507
111
111
149
1529
105
105
143
1556
125
163
163
1577

83
83
83
1488
83
83
83
1504
77
77
77
1527
107
107
107
1498
104
104
141
1519
98
98
136
1545
117
155
155
1564

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 43

Preformed Metal Floor Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 Slab Weight: 48.3 psf
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

80

334
334
334
1917
337
337
337
1972
338
338
338
2034
402
402
402
1953
406
406
406
2012
405
405
405
2077
473
473
473
2122

86

305
305
305
1893
307
307
307
1943
309
309
309
2000
367
367
367
1925
371
371
371
1980
373
373
373
2040
432
432
432
2082

90

96

100

106

Span
110

116

120

126

130

136

140

146

150

280
280
280
1871
282
282
282
1917
284
284
284
1970
337
337
337
1901
340
340
340
1952
342
342
342
2007
396
396
396
2046

258
258
258
1852
260
260
260
1895
262
262
262
1943
311
311
311
1880
314
314
314
1926
316
316
316
1978
365
365
365
2014

239
239
239
1835
241
241
241
1874
242
242
242
1919
288
288
288
1860
290
290
290
1903
292
292
292
1951
338
338
338
1985

222
222
222
1820
224
224
224
1855
225
225
225
1897
267
267
267
1843
270
270
270
1883
272
272
272
1928
314
314
314
1959

166
207
207
1806
167
209
209
1838
168
210
210
1877
249
249
249
1827
252
252
252
1864
253
253
253
1906
293
293
293
1936

153
153
194
1793
154
154
195
1823
154
196
196
1859
233
233
233
1812
235
235
235
1847
237
237
237
1886
274
274
274
1914

141
141
182
1781
142
142
183
1809
142
142
184
1843
219
219
219
1799
221
221
221
1831
222
222
222
1868
257
257
257
1894

130
130
171
1770
131
131
172
1796
131
131
173
1827
206
206
206
1786
208
208
208
1816
209
209
209
1851
242
242
242
1876

120
120
120
1760
121
121
121
1784
121
121
121
1813
152
152
194
1775
154
196
196
1803
154
197
197
1835
228
228
228
1859

111
111
111
1751
112
112
112
1772
112
112
112
1800
141
141
141
1765
143
143
185
1790
144
144
186
1821
216
216
216
1844

103
103
103
1743
104
104
104
1762
104
104
104
1788
132
132
132
1755
133
133
175
1779
134
134
176
1808
204
204
204
1829

95
95
95
1735
96
96
96
1752
96
96
96
1777
123
123
123
1746
124
124
124
1768
125
125
167
1795
150
194
194
1816

89
89
89
1727
89
89
89
1743
89
89
89
1766
115
115
115
1737
116
116
116
1758
116
116
116
1784
141
141
184
1803

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

44

ASC Steel Deck

ASC3 Composite Floor Deck

24
4 Welds
F

ASC3 (24)-Section Properties

ASC3 (24)-Allowable Reaction (PLF)


Gauge1

Bearing
Length

20/20
20/18
20/16
18/20
18/18
18/16
16/16

2
2
2
2
2
2
2

Reaction Location
End
Interior

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

285
285
285
537
537
537
998

20/20
20/18
20/16
18/20
18/18
18/16
16/16

3.35
3.86
4.36
3.95
4.45
4.96
5.56

1.339
1.455
1.536
1.664
1.812
1.933
2.293

0.620
0.622
0.628
0.827
0.850
0.868
1.071

0.570
0.598
0.627
0.744
0.779
0.813
0.995

648
648
648
1245
1245
1245
2020

The first number is the gauge of fluted top sheet.


The second number is the gauge of flat bottom sheet.

1. The section properties are based on 38,000 psi yield stress.


2. The first number is the gauge or thickness of fluted top sheet.
The second number is the gauge or thickness of flat bottom sheet.

ASC2 Composite Floor Deck

24
4 Welds
F

SC2

ASC2 (24)-Allowable Reaction (PLF)


Gauge1

Bearing
Length

20/20
20/18
20/16
18/20
18/18
18/16
16/16

2
2
2
2
2
2
2

ASC2 (24)-Section Properties

Reaction Location
End
Interior

304
304
304
562
562
562
1035

678
678
678
1287
1287
1287
2076

The first number is the gauge of fluted top sheet.


The second number is the gauge of flat bottom sheet.

Effective January 2008

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20/20
20/18
20/16
18/20
18/18
18/16
16/16

3.17
3.68
4.18
3.71
4.19
4.71
5.26

0.618
0.674
0.719
0.761
0.835
0.895
1.060

0.411
0.421
0.430
0.576
0.592
0.605
0.746

0.395
0.415
0.435
0.514
0.539
0.564
0.689

1. The section properties are based on 38,000 psi yield stress.


2. The first number is the gauge or thickness of fluted top sheet.
The second number is the gauge or thickness of flat bottom sheet.

Preformed Metal Deck 45

Preformed Metal Floor Deck

ASC3 Composite Floor Deck


Allowable Superimposed Load (psf) for ASC3 (24) Deck with Concrete Density of 145 pcf
Concrete: Total Slab Thickness: 5 1/2
Steel
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

Slab Weight: 53 psf

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

369
369
369
444
444
444
517
517
517
387
387
387
456
456
456
526
526
526
515
515
515

327
327
327
394
394
394
458
458
458
343
343
343
404
404
404
466
466
466
457
457
457

292
292
292
351
351
351
409
409
409
306
306
306
361
361
361
415
415
415
407
407
407

262
262
262
315
315
315
367
367
367
275
275
275
324
324
324
373
373
373
365
365
365

236
236
236
284
284
284
331
331
331
248
248
248
292
292
292
336
336
336
330
330
330

214
214
214
258
258
258
300
300
300
225
225
225
265
265
265
305
305
305
299
299
299

140
140
140
173
173
173
205
205
205
172
172
172
203
203
203
234
234
234
229
229
229

127
127
127
158
158
158
187
187
187
134
134
159
187
187
187
216
216
216
211
211
211

116
116
116
144
144
144
171
171
171
122
122
122
148
148
148
174
174
199
195
195
195

106
106
106
132
132
132
157
157
157
112
112
112
136
136
136
160
160
160
181
181
181

97
97
97
121
121
121
144
144
144
102
102
102
125
125
125
147
147
147
143
168
168

88
88
88
111
111
111
133
133
133
94
94
94
114
114
114
135
135
135
132
132
132

81
81
81
102
102
102
123
123
123
86
86
86
105
105
105
125
125
125
121
121
121

171
171
195
211
235
235
249
273
273
205
205
205
241
241
241
278
278
278
273
273
273

155
155
155
191
191
191
226
226
250
187
187
187
221
221
221
254
254
254
249
249
249

Allowable Superimposed Load (psf) for ASC3 (24) Deck with Concrete Density of 145 pcf
Concrete: Total Slab Thickness: 6
Slab Weight: 59 psf
Steel
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

415
415
415
498
498
498
578
578
578
438
438
438
514
514
519
590
590
590
581
581
581

368
368
368
441
441
441
512
512
512
388
388
388
455
455
455
522
522
522
515
515
515

328
328
328
393
393
393
457
457
457
346
346
346
406
406
406
466
466
466
459
459
459

294
294
294
353
353
353
410
410
410
310
310
310
364
364
364
418
418
418
412
412
412

266
266
266
319
319
319
370
370
370
280
280
280
329
329
329
377
377
377
372
372
372

214
241
241
262
289
289
308
335
335
254
254
254
298
298
298
342
342
342
337
337
337

158
158
158
194
194
194
230
230
230
194
167
194
228
228
228
262
262
262
258
258
258

143
143
143
177
177
177
209
209
209
152
152
152
183
183
183
214
214
242
238
238
238

130
130
130
161
161
161
192
192
192
139
139
139
167
167
167
196
196
196
220
220
220

119
119
119
148
148
148
176
176
176
126
126
126
153
153
153
179
179
179
204
204
204

109
109
109
135
135
135
161
161
161
116
116
116
140
140
140
165
165
165
162
162
162

100
100
100
124
124
124
149
149
149
106
106
106
129
129
129
152
152
152
149
149
149

91
91
91
114
114
114
137
137
137
97
97
97
119
119
119
140
140
140
137
137
137

193
193
193
236
236
263
278
278
306
231
231
231
272
272
272
312
312
312
307
307
307

174
174
174
214
214
214
252
252
252
212
212
212
249
249
249
285
285
285
281
281
281

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.
2. See pg. 55 for General Notes.

46

ASC Steel Deck

ASC3 Composite Floor Deck


Allowable Superimposed Load (psf) for ASC3 (24) Deck with Concrete Density of 145 pcf
Concrete: Total Slab Thickness: 7 1/2
Slab Weight: 77 psf
Gauge

20/20

20/18

2016

18/20

18/18

18/16

16/16

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

559
559
559
665
665
665
767
767
767
596
596
596
694
694
694
791
791
791
789
789
789

495
495
495
589
589
589
680
680
680
528
528
528
614
614
614
701
701
701
699
699
699

442
442
442
525
525
525
606
606
606
471
471
471
548
548
548
625
625
625
623
623
623

361
361
397
436
471
471
508
544
544
423
423
423
492
492
492
561
561
561
560
560
560

323
323
323
390
390
390
455
455
491
382
382
382
444
444
444
506
506
506
505
505
505

289
289
289
350
350
350
410
410
410
346
346
346
403
403
403
459
459
459
458
458
458

213
213
213
260
260
260
305
305
305
229
229
229
272
272
272
315
315
315
351
351
351

194
194
194
237
237
237
278
278
278
209
209
209
248
248
248
288
288
288
287
287
323

176
176
176
216
216
216
255
255
255
190
190
190
227
227
227
263
263
263
262
262
262

161
161
161
198
198
198
234
234
234
174
174
174
208
208
208
242
242
242
241
241
241

147
147
147
181
181
181
215
215
215
159
159
159
192
191
191
222
222
222
221
221
221

135
135
135
167
167
167
198
198
198
146
146
146
175
175
175
205
205
205
204
204
204

124
124
124
153
153
153
182
182
182
134
134
134
161
161
161
189
189
189
188
188
188

261
261
261
316
316
316
370
370
370
280
280
315
331
367
367
418
418
418
417
417
417

235
235
235
286
286
286
336
336
336
253
253
253
300
300
300
347
347
383
382
382
382

Allowable Superimposed Load (psf) for ASC3 (24) Deck with Concrete Density of 110 pcf
Total Slab Thickness: 5 1/2 Slab Weight: 42 psf
Steel
Gauge

20/20

20/18

20/16

18/20

18/18

18/16

16/16

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

354
354
354
426
426
426
470
470
470
369
369
369
422
422
422
463
463
463
443
443
443

313
313
313
377
377
377
416
416
416
327
327
327
373
373
373
410
410
410
393
393
393

279
279
279
336
336
336
371
371
371
291
291
291
333
333
333
366
366
366
350
350
350

251
251
251
302
302
302
333
333
333
261
261
261
299
299
299
328
328
328
314
314
314

226
226
226
272
272
272
301
301
301
236
236
236
270
270
270
296
296
296
284
284
284

205
205
205
247
247
247
273
273
273
214
214
214
245
245
245
269
269
269
257
257
257

139
139
157
170
189
189
190
209
209
164
164
164
187
187
187
206
206
206
197
197
197

126
126
126
156
156
174
173
173
192
151
151
151
173
173
173
190
190
190
182
182
182

115
115
115
142
142
142
159
159
159
140
140
140
160
160
160
175
175
175
168
168
168

106
106
106
131
131
131
146
146
146
129
129
129
148
148
148
163
163
163
156
156
156

97
97
97
120
120
120
134
134
134
102
102
102
119
119
138
151
151
151
145
145
145

89
89
89
111
111
111
124
124
124
93
93
93
109
109
109
122
122
122
135
135
135

82
82
82
102
102
102
115
115
115
86
86
86
101
101
101
112
112
112
106
126
126

187
187
187
225
225
225
248
248
248
195
195
195
223
223
223
245
245
245
235
235
235

171
171
171
206
206
206
227
227
227
178
178
178
204
204
204
224
224
224
215
215
215

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.
2. See pg. 55 for General Notes.

Effective January 2008

Preformed Metal Deck 47

Preformed Metal Floor Deck

ASC3 Composite Floor Deck


Allowable Superimposed Load (psf) for ASC3 (24) Deck with Concrete Density of 110 pcf
Total Slab Depth: 6 1/4 Slab wt. 49 psf
Steel
Gauge

No. of
Spans

80

20/20

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

421
421
421
504
504
504
584
584
584
442
442
442
518
518
518
594
594
594
584
584
584

20/18

20/16

18/20

18/18

18/16

16/16

86

373
373
373
446
446
446
517
517
517
391
391
391
459
459
459
526
526
526
517
517
517

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

332
332
332
398
398
398
462
462
462
349
349
349
409
409
409
469
469
469
461
461
461

298
298
298
357
357
357
414
414
414
313
313
313
367
367
367
421
421
421
414
414
414

269
269
269
322
322
322
374
374
374
283
283
283
332
332
332
380
380
380
373
373
373

244
244
244
292
292
292
339
339
339
257
257
257
301
301
301
345
345
345
339
339
339

165
165
165
202
202
202
237
237
260
196
196
196
230
230
230
264
264
264
259
259
259

151
151
151
184
184
184
217
217
217
181
181
181
212
212
212
243
243
243
239
239
239

138
138
138
169
169
169
199
199
199
167
145
167
196
196
196
225
225
225
221
221
221

126
126
126
155
155
155
183
183
183
133
133
133
160
160
160
186
186
209
205
205
205

116
116
116
142
142
142
168
168
168
122
122
122
147
147
147
171
171
171
191
191
191

106
106
106
131
131
131
156
156
156
112
112
112
135
135
135
158
158
158
155
178
178

98
98
98
121
121
121
144
144
144
104
104
104
125
125
125
146
146
146
143
143
166

223
223
223
266
266
266
309
309
309
234
234
234
274
274
274
314
314
314
309
309
309

182
182
204
222
244
244
260
283
283
214
214
214
251
251
251
287
287
287
282
282
282

1. Allowable superimposed loads are in pounds per square foot. Shoring is required for deck spans in the shaded areas.
2. See pg. 55 for General Notes.

Diaphragm Shear Capacity for ASC3 (24) with Concrete Fill (PLF) (110 PCF Concrete)
Total Slab Depth: 5 1/2
Gauge

20/20
20/18
20/16
18/20
18/18
18/16
16/16

110 PCF Concrete

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

Q
F
Q
F
Q
F
Q
F
Q
F
Q
F
Q
F

1540
1.12
1640
0.91
1740
0.76
1540
1.12
1640
0.91
1740
0.76
1740
0.76

1520
1.14
1600
0.93
1700
0.78
1520
1.14
1600
0.93
1700
0.78
1700
0.78

1500
1.15
1580
0.95
1670
0.80
1500
1.15
1580
0.95
1670
0.80
1670
0.80

1480
1.17
1550
0.96
1640
0.81
1480
1.17
1550
0.96
1640
0.81
1640
0.81

1460
1.18
1530
0.98
1610
0.83
1460
1.18
1530
0.98
1610
0.83
1610
0.83

1450
1.19
1510
0.99
1580
0.84
1450
1.19
1510
0.99
1580
0.84
1580
0.84

1410
1.23
1450
1.02
1510
0.88
1410
1.23
1450
1.02
1510
0.88
1510
0.88

1400
1.24
1440
1.03
1500
0.89
1400
1.24
1440
1.03
1500
0.89
1500
0.89

1390
1.24
1430
1.04
1480
0.90
1390
1.24
1430
1.04
1480
0.90
1480
0.90

1380
1.25
1410
1.05
1460
0.91
1380
1.25
1410
1.05
1460
0.91
1460
0.91

1370
1.26
1400
1.06
1450
0.92
1370
1.26
1400
1.06
1450
0.92
1450
0.92

1360
1.27
1390
1.07
1440
0.93
1360
1.27
1390
1.07
1440
0.93
1440
0.93

1350
1.28
1380
1.08
1420
0.93
1350
1.28
1380
1.08
1420
0.93
1420
0.93

1430
1.20
1490
1.00
1560
0.85
1430
1.20
1490
1.00
1560
0.85
1560
0.85

1. Q is the allowable diaphragm shear capacity in pounds per linear foot.


2. F is the flexibility factor.

48

1420
1.22
1470
1.01
1530
0.87
1420
1.22
1470
1.01
1530
0.87
1530
0.87

ASC Steel Deck

ASC3 Composite Floor Deck


Diaphragm Shear Capacity for ASC3 (24) with Concrete Fill (PLF) (110 PCF Concrete)
Total Slab Depth: 6 1/4 110 PCF Concrete
Gauge

20/20
20/18
20/16
18/20
18/18
18/16
16/16

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

Q
F
Q
F
Q
F
Q
F
Q
F
Q
F
Q
F

1780
0.97
1870
0.79
1980
0.67
1780
0.97
1870
0.79
1980
0.67
1980
0.67

1760
0.98
1840
0.81
1940
0.68
1760
0.98
1840
0.81
1940
0.68
1940
0.68

1740
0.99
1810
0.82
1900
0.70
1740
0.99
1810
0.82
1900
0.70
1900
0.70

1720
1.01
1790
0.83
1870
0.71
1720
1.01
1790
0.83
1870
0.71
1870
0.71

1700
1.02
1760
0.84
1840
0.72
1700
1.02
1760
0.84
1840
0.72
1840
0.72

1680
1.02
1740
0.85
1820
0.73
1680
1.02
1740
0.85
1820
0.73
1820
0.73

1640
1.05
1690
0.88
1750
0.76
1640
1.05
1690
0.88
1750
0.76
1750
0.76

1630
1.06
1680
0.89
1730
0.77
1630
1.06
1680
0.89
1730
0.77
1730
0.77

1620
1.06
1660
0.90
1720
0.77
1620
1.06
1660
0.90
1720
0.77
1720
0.77

1610
1.07
1650
0.90
1700
0.78
1610
1.07
1650
0.90
1700
0.78
1700
0.78

1610
1.07
1640
0.91
1690
0.79
1610
1,07
1640
0.91
1690
0.79
1690
0.79

1600
1.08
1630
0.91
1670
0.79
1600
1.08
1630
0.91
1670
0.79
1670
0.79

1590
1.09
1620
0.92
1660
0.80
1590
1.09
1620
0.92
1660
0.80
1660
0.80

1670
1.03
1720
0.86
1790
0.74
1670
1.03
1720
0.86
1790
0.74
1790
0.74

1660
1.04
1710
0.87
1770
0.75
1660
1.04
1710
0.87
1770
0.75
1770
0.75

Diaphragm Shear Capacity for ASC3 (24) with Concrete Fill (PLF) (145 PCF Concrete)
Total Slab Depth: 5 1/2 145 PCF Concrete
Gauge

20/20
20/18
20/16
18/20
18/18
18/16
16/16

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

Q
F
Q
F
Q
F
Q
F
Q
F
Q
F
Q
F

1950
0.89
2040
0.73
2150
0.62
1950
0.89
2040
0.73
2150
0.62
2150
0.62

1920
0.90
2010
0.74
2110
0.63
1920
0.90
2010
0.74
2110
0.63
2110
0.63

1900
0.91
1980
0.75
2070
0.64
1900
0.91
1980
0.75
2070
0.64
2070
0.64

1880
0.92
1960
0.76
2040
0.65
1880
0.92
1960
0.76
2040
0.65
2040
0.65

1870
0.92
1930
0.77
2010
0.66
1870
0.92
1930
0.77
2010
0.66
2010
0.66

1850
0.93
1910
0.78
1990
0.67
1850
0.93
1910
0.78
1990
0.67
1990
0.67

1840
0.94
1890
0.79
1960
0.68
1840
0.94
1890
0.79
1960
0.68
1960
0.68

1820
0.95
1870
0.79
1940
0.68
1820
0.95
1870
0.79
1940
0.68
1940
0.68

1810
0.95
1860
0.80
1920
0.69
1810
0.95
1860
0.80
1920
0.69
1920
0.69

1800
0.96
1840
0.81
1990
0.70
1800
0.96
1840
0.81
1900
0.70
1900
0.70

1790
0.96
1830
0.81
1880
0.70
1790
0.96
1830
0.81
1880
0.70
1880
0.70

1780
0.97
1820
0.82
1870
0.71
1780
0.97
1820
0.82
1870
0.71
1870
0.71

1770
0.97
1810
0.82
1850
0.72
1770
0.97
1810
0.82
1850
0.72
1850
0.72

1770
0.98
1800
0.83
1840
0.72
1770
0.98
1800
0.83
1840
0.72
1840
0.72

1760
0.98
1790
0.83
1830
0.73
1760
0.98
1790
0.83
1830
0.73
1830
0.73

2120
0.81
2190
0.68
2280
0.58
2120
0.81
2190
0.68
2280
0.58
2280
0.58

2110
0.82
2170
0.69
2250
0.59
2110
0.82
2170
0.69
2250
0.59
2250
0.59

2090
0.83
2150
0.69
2220
0.60
2090
0.83
2150
0.69
2220
0.60
2220
0.60

2080
0.83
2130
0.70
2200
0.60
2080
0.83
2130
0.70
2200
0.60
2200
0.60

2060
0.84
2110
0.70
2180
0.61
2060
0.84
2110
0.70
2180
0.61
2180
0.61

2050
0.84
2100
0.71
2160
0.62
2050
0.84
2100
0.71
2160
0.62
2160
0.62

2040
0.85
2080
0.71
2140
0.62
2040
0.85
2080
0.71
2140
0.62
2140
0.62

2030
0.85
2070
0.72
2120
0.63
2030
0.85
2070
0.72
2120
0.63
2120
0.63

2020
0.85
2060
0.72
2110
0.63
2020
0.85
2060
0.72
2110
0.63
2110
0.63

2010
0.86
2050
0.73
2090
0.63
2010
0.86
2050
0.73
2090
0.63
2090
0.63

2000
0.86
2030
0.73
2080
0.64
2000
0.86
2030
0.73
2080
0.64
2080
0.64

2000
0.86
2020
0.74
2070
0.64
2000
0.86
2020
0.74
2070
0.64
2070
0.64

Total Slab Depth: 6 145 PCF Concrete


20/20
Q
2190 2160 2140
F
0.79 0.80 0.81
20/18
Q
2280 2250 2220
F
0.65 0.66 0.67
20/16
Q
2390 2350 2310
F
0.56 0.57 0.57
18/20
Q
2190 2160 2140
F
0.79 0.80 0.81
18/18
Q
2280 2250 2220
F
0.65 0.66 0.67
18/16
Q
2390 2350 2310
F
0.56 0.57 0.57
16/16
Q
2390 2350 2310
F
0.56 0.57 0.57

1. Q is the allowable diaphragm shear capacity in pounds per linear foot.


2. F is the flexibility factor.

Effective January 2008

Preformed Metal Deck 49

Preformed Metal Floor Deck

ASC3 Composite Floor Deck


Diaphragm Shear Capacity for ASC3 (24) with Concrete Fill (PLF) (145 PCF Concrete)
Total Slab Depth: 7 1/2

145 PCF Concrete

Steel
Gauge

No. of
Spans

80

86

90

96

100

Deck Span
106 110 116

120

126

130

136

140

146

150

20/20

Q
F
Q
F
Q
F
Q
F
Q
F
Q
F
Q
F

2910
0.59
3000
0.50
3110
0.43
2910
0.59
3000
0.50
3110
0.43
3110
0.43

2880
0.60
2970
0.50
3070
0.43
2880
0.60
2970
0.50
3070
0.43
3070
0.43

2860
0.60
2940
0.51
3030
0.44
2860
0.60
2940
0.51
3030
0.44
3030
0.44

2840
0.61
2910
0.51
3000
0.44
2840
0.61
2910
0.51
3000
0.44
3000
0.44

2820
0.61
2890
0.52
2970
0.45
2820
0.61
2890
0.52
2970
0.45
2970
0.45

2810
0.61
2870
0.52
2940
0.45
2810
0.61
2870
0.52
2940
0.45
2940
0.45

2770
0.62
2820
0.53
2880
0.46
2770
0.62
2820
0.53
2880
0.46
2880
0.46

2760
0.63
2800
0.53
2860
0.46
2760
0.63
2800
0.53
2860
0.46
2860
0.46

2750
0.63
2790
0.53
2840
0.47
2750
0.63
2790
0.53
2840
0.47
2840
0.47

2740
0.63
2770
0.54
2830
0.47
2740
0.63
2770
0.54
2830
0.47
2830
0.47

2730
0.63
2760
0.54
2810
0.47
2730
0.63
2760
0.54
2810
0.47
2810
0.47

2720
0.63
2750
0.54
2800
0.47
2720
0.63
2750
0.54
2800
0.47
2800
0.47

2710
0.64
2740
0.54
2780
0.48
2710
0.64
2740
0.54
2780
0.48
2780
0.48

20/18
20/16
18/20
18/18
18/16
16/16

2790
0.62
2850
0.52
2920
0.46
2790
0.62
2850
0.52
2920
0.46
2920
0.46

2780
0.62
2830
0.53
2900
0.46
2780
0.62
2830
0.53
2900
0.46
2900
0.46

1. The first number of the deck gauge is the gauge of the fluted top sheet. Second number is the gauge of the flat bottom sheet
2. Q is the allowable diaphragm shear capacity in pounds per linear foot.
3. F is the flexibility factor.

Allowable Shear and Flexibility Factors on Diaphragms using ASC3 (24) Electri-Deck
Floor System with Trench Header 1,2,3,4
Deck Gauge Combination
Cellular
Noncellular

20/20
20/18
20/16
18/20
18/18
18/16
16/16
None
1.
2.
3.
4.

20 thru 16
20 thru 16
20 thru 16
20 thru 16
20 thru 16
20 thru 16
20 thru 16
20 thru 16

Allowable
Diaphragm Shear

1670
1670
1670
1670
1670
1670
1670
1710

Flexibility Factor5
FC
FT

0.42
0.42
0.42
0.42
0.42
0.42
0.42
0.42

0.89
0.89
0.89
0.89
0.89
0.89
0.89
1.5

Maximum deck span is 12 feet.


Maximum trench header width is 36 inches.
Concrete fill is 2-1/2 inches minimum above top of deck flutes.
FC= Flexibility factor for concrete.
FT=Flexibility factor for trench.

For decks with trench headers, w is equal to the calculated deflection of the trench added to the deflection of the concrete outside of the trench.

5.

50

ASC Steel Deck

CF 7/8 Concrete Form


CF 7/8-Section Properties
Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

26
24
22
20

1.04
1.33
1.62
1.94

0.027
0.035
0.043
0.051

0.06
0.078
0.095
0.113

0.06
0.078
0.095
0.113

2-2/3

7/8

32 Net Coverage

Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

CF-7/8
Gauge

26
SINGLE
SPAN

24
22
20
26

DOUBLE
SPAN

24
22
20
26

TRIPLE
SPAN

24
22
20

stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl

20

26

30

36

40

Span (Ft)
46

50

56

60

66

70

360
295
468
382
570
470
678
557
360
360
468
468
570
570
678
678
450
450
585
585
713
713
848
848

230
151
300
196
365
241
434
285
230
230
300
300
365
365
434
434
288
285
374
369
456
453
542
538

160
87
208
113
253
139
301
165
160
160
208
208
253
253
301
301
200
164
260
213
317
262
377
311

118
55
153
71
186
88
221
104
118
118
153
153
186
186
221
221
147
103
191
134
233
165
277
196

90
37
117
48
143
59
170
70
90
88
117
115
143
141
170
167
113
69
146
90
189
110
212
131

71
26
92
34
113
41
134
49
71
62
92
80
113
99
134
117
89
48
116
63
141
77
167
92

58
19
75
24
91
30
108
36
58
45
75
58
91
72
108
85
72
35
94
46
114
56
136
67

48
14
62
18
75
23
90
27
48
34
62
44
75
54
90
64
60
26
77
34
94
42
112
50

40
11
52
14
63
17
75
21
40
26
52
34
63
41
75
49
50
20
65
26
79
32
94
38

34
9
44
11
54
14
64
16
34
20
44
26
54
32
64
39
43
16
55
21
67
25
80
30

29
7
38
9
47
11
55
13
29
16
38
21
47
26
55
31
37
12
48
16
58
20
69
24

1. Stress based on allowable flexural stress of 36 ksi.


2. Deflection based on maximum deflection of L/180.
3. Adequate bearing must be provided.

Effective January 2008

Preformed Metal Deck 51

Preformed Metal Floor Deck

CF 1 3/8 Concrete Form


4-9/16

CF 1 3/8-Section Properties
1-3/8

32
F

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

26
24
22
20
18

1.04
1.33
1.62
1.92
2.56

0.072
0.065
0.122
0.146
0.195

0.094
0.131
0.169
0.205
0.263

0.094
0.131
0.169
0205
0.263

Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

CF-1 3/8
Gauge

26
24
SINGLE
SPAN

22
20
18
26
24

DOUBLE
SPAN

22
20
18
26
24

TRIPLE
SPAN

22
20
18

stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl
stress
defl

30

36

40

46

50

Span (Ft)
56

60

66

70

76

80

251
233
349
317
451
395
547
473
444
444
251
251
349
349
451
451
547
547
444
444
313
313
437
437
563
563
683
683
555
555

184
147
257
200
331
249
402
298
326
326
184
184
257
257
331
331
402
402
326
326
230
230
321
321
414
414
502
502
407
407

141
98
197
134
254
167
308
199
249
249
141
141
197
197
254
254
308
308
249
249
176
176
246
246
319
319
384
376
312
312

111
69
155
94
200
117
243
140
197
187
111
111
155
155
200
200
243
243
197
197
139
130
194
177
250
220
304
264
246
246

90
50
126
69
162
85
197
102
159
136
90
90
126
126
162
162
197
197
159
159
113
95
157
129
203
160
246
192
199
199

75
38
104
51
134
64
163
77
132
102
75
75
104
104
134
134
163
163
132
132
93
71
130
97
168
120
203
144
165
165

63
29
87
40
113
49
137
59
111
79
63
62
87
87
113
113
137
137
111
111
78
54
109
74
141
93
171
111
138
138

53
23
74
31
96
39
116
46
94
62
53
53
74
74
96
93
116
111
94
94
67
43
93
58
120
73
146
87
118
117

46
18
64
25
83
31
100
37
81
50
46
44
64
60
83
74
100
89
81
81
58
34
80
47
103
58
126
70
101
93

40
15
56
20
72
25
87
30
71
40
40
35
56
48
72
60
87
72
71
71
50
28
70
38
90
47
109
57
88
76

35
12
49
17
63
21
77
25
62
33
35
29
49
40
63
50
77
59
62
62
44
23
61
31
79
39
96
47
78
62

1. Stress based on allowable flexural stress of 36 ksi (for 18 ga. stress based on allowable flexural stress of 22.8 ksi).
2. Deflection based on maximum deflection of L/180.
3. Adequate bearing must be provided.

52

ASC Steel Deck

Deep Deck (Form)


9

4 1/2 Deep Deck -Section Properties


Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20
18
16
14

2.86
3.74
4.69
5.86

2.44
3.42
4.36
5.49

0.924
1.266
1.608
2.056

0.957
1.313
1.635
2.056

4-1/2

12
F

1. Section properties are based on minimum 33 ksi steel (Fy)

4 1/2 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)
Span
Condition

Gauge

20
SINGLE
SPAN

100

120

140

160

180

Span (Ft)
200

220

240

260

280

300

123
123
169
169
214
214
274
274

86
86
117
117
149
149
190
190

63
58
86
82
109
104
140
131

48
39
66
55
84
70
107
88

38
27
52
38
66
49
85
62

31
20
42
28
54
36
69
45

25
15
35
21
44
27
57
34

21
12
29
16
37
21
48
26

18
9
25
13
32
16
41
20

16
7
22
10
27
13
35
16

14
6
19
8
24
11
30
13

Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl

18
16
14

6 Deep Deck - Section Properties

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20
18
16
14

3.22
4.22
5.29
6.61

4.79
6.68
8.56
10.78

1.386
1.892
2.406
3.085

1.314
1.966
2.451
3.087

1. Section properties are based on minimum 33 ksi steel (Fy)

12
F

6 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

Gauge

20
SINGLE
SPAN

18
16
14

Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl

100

120

140

160

180

Span (Ft)
200

220

240

260

280

300

185
185
252
252
321
321
411
411

128
128
175
175
223
223
268
286

94
94
129
129
164
164
210
210

72
72
99
99
125
125
161
161

57
54
78
75
99
96
127
121

46
39
63
55
80
70
103
88

38
29
52
41
66
53
85
66

32
23
44
32
56
41
71
51

27
18
37
25
47
32
61
40

24
14
32
20
41
26
52
32

21
12
28
16
36
21
46
26

1. Loads based on bending stress limit of Fb=20 ksi or deflection limit of L/240.
2. Bearing must be checked using actual loads and bearing lengths.

Effective January 2008

Preformed Metal Deck 53

Preformed Metal Floor Deck

Deep Deck (Form)


9

7 1/2 Deep Deck -Section Properties

7-1/2

Gauge

Weight
(psf)

I
(In4)

S+
(In3)

S-(In3)

20
18
16
14

3.59
4.7
5.9
7.38

8.11
11.28
14.47
18.26

1.899
2.593
3.3
4.238

1.67
2.528
3.367
4.245

1. Section properties are based on minimum 33 ksi steel (Fy)


12

7 1/2 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)
Span
Condition

Gauge

20
Single
Span

18
16
14

Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl

100

120

140

160

180

Span (Ft)
200

220

240

260

280

300

253
253
346
346
440
440
565
565

176
176
240
240
306
306
392
392

129
129
176
176
224
224
288
288

99
99
135
135
172
172
221
221

78
78
107
107
136
136
174
174

63
63
86
86
110
110
141
141

52
50
71
69
91
89
117
112

44
38
60
53
76
69
98
87

37
30
51
42
65
54
84
68

32
24
44
34
56
43
72
55

28
20
38
27
49
35
63
44

1. Loads based on bending stress limit of Fb=20 ksi or deflection limit of L/240.
2. Bearing must be checked using actual loads and bearing lengths.

54

ASC Steel Deck

General Notes
The following notes apply to the allowable total load tables and/or
to the allowable superimposed load & diaphragm shear tables.
1. Arc spot or arc seam (puddle) welds shall have an
effective fusion area, to supporting members,
equivalent to at least 3/8" by 1" long or 1/2" in diameter.
2. Spacing of marginal welds to members parallel to the
flutes:
(a) Arc spot (puddle) welds to members, such as
chords, and to collector elements, such as struts
or ties, shall have a spacing in feet equal to
32,000 (t) /v, where:
t = Uncoated steel thickness of fluted deck in
inches. (see ICC report for "t")
v = Actual diaphragm shear at marginal supports
or actual shear transferred to collector (at
struts or ties) in pounds per foot.
(b) Fillet welds to members, such as diaphragm
chords, shall have a spacing in feet equal to 480
I w / v, where:
lw = Length of weld in inches (not less than 1 1/2
v = Actual diaphragm shear to be transferred to
chords in pounds per foot.
(c) Fillet welds attaching the diaphragm to struts, ties
or other collector elements shall have a spacing,
in feet, equal to 300 I w / v where:
v = Actual diaphragm shear to be transferred to the
collector element, in pounds per foot.
(d) In no case shall any weld spacing exceed 3'0".
3. Attachments at interior lines of shear transfer,
perpendicular to deck corrugations:
(a) The shear transfer from a diaphragm to interior
ties or strut lines, perpendicular to deck
corrugations, shall not exceed the shear values
indicated in the tables. Two lines of puddle welds
may be used to develop the actual shear transfer to
these collector elements.

Effective January 2008

4.

The minimum 28-day compressive strength for


structural concrete shall be 3000 psi and the density as
indicated in the tables or as required for fire rating. The
minimum depth of concrete shall be 2" over the top
flange and it is to be reinforced with a minimum 6 x 6
W1.4 x W1.4 welded wire fabric. The reinforcement shall be
placed near the center of the fill, over the top flange.
If fill exceeds 3 1/4" thick the reinforcement area must
equal 0.00075 times the depth of fill over top of deck, each
way.
5. All decks with structural concrete fill may be considered
rigid diaphragms, f<1.0, unless otherwise noted.
6. Shoring calculations are based on the deck profile
supporting the dead load of concrete, plus either:
(a) a 20 psf uniform construction load, or
(b) a 150 lb. concentrated live load for flexure.
The dead load deflection is limited to L/180, but not to
exceed 3/4".
7. Total Slab Thickness: is the nominal total slab depth,
measured from the bottom flange of the rib to the top of
the concrete. This applies to all allowable
superimposed load and diaphragm shear tables.
8. For all cellular profiles, the first number of the gauge
designation (20/20) refers to beam section (corrugated
profile). The second number (20/20) refers to the pan
section (flat plate).
9. Seam attachment for composite floor deck to be
minimum button punch @ 36" O.C.
10. Typical floor deck manufacturing tolerances:
Panel length: +/- 1/2"
Thickness: Not less than 95% of the design
base metal thickness
Panel cover width: -3/8", + 3/4"
Panel camber/sweep: 1/4" in 10' length
Panel end out of square: 1/8" per foot of panel width

Preformed Metal Deck 55

Preformed Metal Floor Deck

Fire Resistance Ratings


Fire Resistance Rating-Floor Deck
Restrained
Assembly
Hourly Rating

1,1 1/2, 2 & 3


3&
1, 1 1/2, 2
1,1 1/2 & 2
1, 1 1/2, 2, 3 & 4
2
1, 1 1/2, 2 & 3
3
2&3
1, 1 1/2, 2 & 3
2, 3 & 4
3&4
2
3
3
1, 1 1/2, 2 & 3
1, 1 1/2, 2, 3 & 4
2
1, 1 1/2, 2 & 3
2&3
2
1, 1 1/2, 2, 3 & 4
2
3
1, 1 1/2, 2 & 3
1, 1 1/2, 2 & 3
2
1
1
1 1/2
1 1/2
2
2
3
3
2
3/4 or 1
3/4 or 1
1
1 1/2
1 1/2
2
2
3
3
1
1
1 1/2
2
2
3
3

56

UL
Design No.

D703
D708
D712
D722
D739
D740
D743
D753
D755
D759
D760
D754
D764
D768
D776
D780
D782
D826
D832
D833
D840
D858
D861
D863
D859
D871
D756

D902

D907
D914

D916
D925
D927

D918

Concrete Thickness
(Above Deck)
Type

2 1/2 LWT & NWT


2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 NWT
2 LWT & NWT
2 3/4 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
2 1/2 LWT
2 1/2 LWT & NWT
2 3/4 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
3 1/4 LWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 3/4 LWT & NWT
2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
3 1/4 LWT
2 1/2 LWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
2 1/2 LWT
3 1/2 NWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT

Profile

Fireproofing Type

2W, 3W, ASC2 & ASC3


B, BF, N, NF, 2W & 3W
N, NF, 2W, ASC2 & ASC3
N, NF, 2W, 3W, ASC2 & ASC 3
B, BF, N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3
B
2W, 2WF, 3W, 3WF, ASC2 & ASC3
CF-7/8 & CF-1 3/8
B, BF, 2W, 3W, ASC2 & ASC3
B, 2W, 2WF, 3W, 3WF, ASC2 & ASC3
B, 2W & 3W
B, N, 2W & 3W
B, BF N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3
B, BF, N, NF, 2W & 3W
CF-7/8 & CF-1 3/8
CF-7/8 & CF-1 3/8
B, N, 2W & 3W
B, BF, N, NF, 2W & 3W
B, BF, 2W, 3W, ASC2 & ASC3
2W
B, BF, N, NF, 2W & 3W
2W, 3W, ASC2 & ASC3
2W
CF-7/8 & CF-1 3/8
2W, 3W, ASC2 & ASC3
2W & 3W
ASC2 & ASC3

Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
None
Fiberous
Fiberous
None
Fiberous
Fiberous
Fiberous
Fiberous
Fiberous
Cementitious

B, BF, N, NF, 2W, 2WF, 3W, 3WF


ASC2 & ASC3

None

B, BF, N, NF, 2W, 2WF, 3W, 3WF, ASC2 & ASC3


B, BF, N, NF, 2WF, 3W, 3WF, ASC2 & ASC3

None
None

B, BF, N, NF, 2W, 2WF, 3W, 3WF


ASC2 & ASC3

None

B, BF, N, NF, 2W, 2WF, 3W, 3WF


ASC2 & ASC3

None

ASC Steel Deck

Fire Resistance Ratings continued


Fire Resistance Rating-Floor Deck
Restrained
Assembly
Hourly Rating

UL
Design No.

1
1
1 1/2
1 1/2
2
2
3
3
2
3/4 or 1
1
1 1/2
1 1/2
2
2

D919
D931

D920

D929

Concrete Thickness
(Above Deck)
Type

2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
3 1/4 LWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT

Profile

Fireproofing Type

B, BF, N, NF, 2W, 2WF, 3W, 3WF


ASC2 & ASC3

None

2W, 2WF, 3W, 3WF, ASC2 & ASC3

None

B, BF, N, NF, 2W, 2WF, 3W, 3WF


ASC2 & ASC3

None

Shear Stud Data


Allowable Shear Stud Capacity (KIPS/Stud)
Profile

B-36 Hi Form
2W-36 (24)
3W-36 (24)

3/4 Headed Stud


Welded Length (in.)

3
3.5
3.8 or 4.5
3.5, 3.8, 4.5, 4.8, or 5.0
4.5
4.8
5.0
5.5

Normal Weight Concrete (145 PCF)


1 Stud
2 Studs
3 Studs
Per Flute
Per Flute
Per Flute

11.50
11.50
11.50
11.50
9.78
11.50
11.50
11.50

9.22
11.50
11.50
11.50
6.91
8.35
9.21
11.50

11.50
5.65
6.82
7.52
9.41

Lightweight Concrete (110 PCF)


1 Studs
2 Studs
3 Studs
Per Flute
Per Flute
Per Flute

9.54
9.54
9.54
9.54
8.12
9.54
9.54
9.54

7.64
9.54
9.54
9.54
5.74
6.93
7.64
9.54

9.54
4.69
5.66
6.24
7.81

1. Based on 3000 psi concrete


2. Based on A.I.S.C. specifications
3. Note: Additional reinforcing steel may be required at composite beams.

Effective January 2008

Preformed Metal Deck 57

Preformed Metal Floor Deck

Concrete Weights and Volumes


ASC
Description

Cubic Yards
Per 100 Sq.
Ft. of Area

LIGHTWEIGHT
Concrete
(110 Pcf)
Wt. Per Sq.
Ft. of Area

NORMAL
WEIGHT
Concrete
(145 Pcf)
Wt. Per Sq.
Ft. of Area

Depth of Slab Over the Top of the Rib

Profile

2 1/2

3 1/4

3 1/2

4 3/16

4 1/4

4 1/2

B-36, BF-36
ShearVent
BR-36
2W, 2WF
3W, 3WF
N-24, NF-24
NR-24
CP-32
CF-7/8
CF-1 3/8
ASC2 (24)
ASC2 (30)
ASC3 (24)
ASC3 (30)
B-36, BF-36
BR-36
2W, 2WF
3W, 3WF
N-24, NF-24
NR-24
CF-7/8
CF-1 3/8
ASC2 (24)
ASC2 (30)
ASC3 (24)
ASC3 (30)
B-36, BF-36
BR-36
2W, 2WF
3W, 3WF
N-24, NF-24
NR-24
CF-7/8
CF-1 3/8
ASC2 (24)
ASC2 (30)
ASC3 (24)
ASC3 (30)

0.927
0.927
1.079
1.080
1.236
1.039
1.430
0.984
0.907
0.984
1.035
1.106
1.227
1.321
27.531
32.046
32.076
36.079
30.858
42.471
26.938
29.225
30.737
32.847
36.448
39.251
36.292
42.243
42.282
48.389
40.677
55.985
35.509
38.524
40.524
43.295
48.053
51.735

1.082
1.082
1.233
1.235
1.389
1.194
1.584
1.138
1.061
1.138
1.189
1.260
1.382
1.476
32.135
36.620
36.680
41.253
35.462
47.045
31.512
33.800
35.320
37.431
41.030
43.385
42.360
48.222
48.350
54.379
46.754
62.014
41.538
66.553
46.566
49.336
54.095
57.777

1.159
1.159
1.130
1.312
1.466
1.271
1.661
1.215
1.138
1.215
1.267
1.337
1.459
1.553
34.422
39.907
39.966
43.540
37.749
49.332
33.799
36.084
37.611
39.723
43.322
46.127
45.375
51.287
51.365
57.394
49.760
65.028
44.553
47.567
49.587
52.358
57.116
60.798

1.236
1.236
1.388
1.389
1.543
1.348
1.739
1.292
1.215
1.282
1.343
1.414
1.536
1.630
36.709
41.224
41.253
45.827
40.036
51.648
36.086
38.372
39.902
42.015
45.613
48.419
48.389
54.340
54.379
60.408
52.744
68.082
47.567
50.582
52.608
55.379
60.137
63.819

1.390
1.390
1.542
1.543
1.698
1.502
1.893
1.447
1.370
1.447
1.498
1.569
1.690
1.784
41.283
45.797
45.827
50.431
44.609
56.222
40.869
42.976
44.485
46.599
50.196
53.003
54.419
60.369
60.408
66.477
58.803
74.111
53.636
56.650
58.650
61.421
66.179
69.861

1.448
1.448
1.600
1.601
1.755
1.560
1.951
1.505
1.427
1.505
1.556
1.627
1.748
1.842
43.006
47.520
47.550
52.124
46.332
57.945
42.382
44.700
46.204
48.318
51.915
54.722
56.689
62.640
62.679
68.708
61.074
76.382
55.867
58.921
60.916
63.686
63.445
72.126

1.467
1.467
1.619
1.620
1.775
1.579
1.970
1.524
1.447
1.524
1.575
1.646
1.767
1.861
43.570
48.084
48.114
52.716
46.896
58.509
42.976
45.263
46.777
48.891
52.487
55.295
57.433
63.384
63.423
69.491
61.818
77.126
56.650
59.665
61.671
64.442
69.199
72.882

1.545
1.545
1.696
1.696
1.852
1.657
2.047
1.601
1.524
1.601
1.652
1.723
1.845
1.939
45.887
50.371
50.431
55.004
49.213
60.796
45.263
47.550
49.068
51.183
54.779
57.587
60.487
66.398
66.477
72.506
64.872
80.140
59.665
62.679
64.692
67.463
72.221
75.902

1. Deck deflection not considered.


2. Placement of concrete is to comply with ACI Manual of Concrete Practice.
Code Approvals
ASCs steel deck profiles have been evaluated or approved for use by:
1. ICC Evaluation Service Report No. 1414.
2. City of Los Angeles Research Report Nos. 23783 and 23784.
3. Factory Mutual
58

ASC Steel Deck

Comments on Extraordinary Conditions


A. Positive Bending Reinforcement
The deck profile in a composite slab design is the
positive bending reinforcement for the slab and must be
expected to last the life of the structure. To ensure the
integrity of the structure, ASC Steel Deck recommends
specifying ASTM A653, G-60 as the minimally acceptable finish.
B. Parking Structures
The following conditions are to be considered when
using steel deck in a parking structure.
1. All slabs are to be designed as continuous spans
with negative reinforcement placed over each
support. Alternatively, the steel deck may be used
as a concrete form with reinforcement as required.
2. Additional reinforcing is to be included to
minimize cracking caused by temperature
differential and to provide load distribution.
3. The minimally acceptable galvanized coating is
G-90, as per ASTM A653.
4. In corrosive environments, the top surface of the
slab is to be sealed and the bottom surface of the
steel deck is to receive a field applied finish paint.
C. Vibratory Load
Vibratory Loads, e.g., mechanical equipment and forklifts are
detrimental to the mechanical bond between the
deck and concrete. Additional reinforcing steel, designed
by the structural engineer, may be required.

E.

Cantilevers
Steel deck used in a cantilevered condition acts solely
as a permanent form. The length of the cantilever may
be determined using the section properties of the steel
deck profile. Negative reinforcement, designed by the
structural engineer, is to be added over the support to
prevent cracking of the slab.

F.

1% Venting
Steel decking used in composite construction should
be vented when the slab may be exposed to
water, post construction. The vented steel deck
will allow the dissipation of residual water vapor. The venting
may be produced using punched hole or vent tabs.
Contact ASC for more specific information per the
specific profile.

Alternative Fastening Methods


For attachment of decking, for methods other than welding, refer to
the following technical information:
Screwed and Pinned Attachments
ICBO Report No.
Company
3056
ITW, Buildex Division
3829
Pneutek,Inc.
4373
HILTI Fastening Systems

D. Point Load
To determine the required deck type and concrete for
a point load condition, an equivalent uniform load for a
simple span is calculated.
Example:
1. 10'0" Span
2. 400 # Point Load at Mid-Span
3. 50 PSF Uniform Floor Load
Determine total equivalent uniform superimposed load.
A. Maximum Moment from Point Load:
M=PL/4=400(10)/4=1000 ft. Ibs.
B. Equivalent Uniform Load:
W=M(8) =1000(8) = 80 PSF
10
L
C. Total Equivalent Superimposed Load:
50 + 80 = 130 PSF
* Note: Select deck type, concrete type and
thickness with a 130 PSF allowable superimposed load capacity and span length of
10'0". Provide distribution steel as required.
2

Effective January 2008

Preformed Metal Deck 59

Preformed Metal Floor Deck

SDI Edge Form


SDI is the Steel Deck Institute, the author of the following table.

10

11

12

4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00

20
20
20
20
20
20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10

20
20
20
20
20
18
18
18
18
18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10

20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

12
12
12
10
10
10
10
10
10
10
10
10
10

10
10
10
10
10
10
10
10
10

10
10
10
10

1/

m
in
.

Slab
Depth

1 Fillet Welds @ 12 O.C.


Pour
Stop

Slab
Depth

Edge Form Detail

2 min.
Overhang
The above Selection Table is based on following criteria:
F
1. Normal weight concrete (150 pcf).
2. Horizontal and vertical deflection is limited to 1/4 maximum for concrete dead load
3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf.
4. Pour Stop Selection Table does not consider the effect of the performance, deflection, or rotation of the pour stop support which may
include both the supporting composite deck and/or the frame.
5. Vertical leg return lip is recommended for type 16 and lighter.
6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only.
7. SDI reserves the right to change any information in this section without notice.

60

ASC Steel Deck

Floor Deck Accessories and Standard Details


F

Profile
Closures
Profile Closures

Filler Plate
Varies
Not to exceed 8
(clear span)

Small Void

Large Void
F

R
Raised

Curved Weld Washers

Edge Weld Washer

14 gauge x 3/8 dia.


hole for welded
attachment of CF 7/8
3/4

Z Closure

Edge Form
1

14 gauge x 3/8 dia.


hole for welded
attachment of
CF 1 3/8

Cell Closure
1/2

Recommended for 16 ga. and lighter.


1

Varies
(Based on
deck height)

Varies
(Based on
Slab Height)

Varies
(Based on deck
height)
1-1/2

Varies
(Based on Gauge)

F
Edge From
at the Perpendicular
Condition

Edge From at the Parallel Condition

Stud Locations

Effective January 2008

Filler Plate

Cell Closure

Preformed Metal Deck 61

Preformed Metal Floor Deck

Composite Floor Deck Specifications


Part l-General
1.01 Work Included
A. Furnish all materials and labor necessary to complete
metal decking installation per the Contract Documents.
1.02 Related Work, Specified Elsewhere
A. The work of this Section shall be closely coordinated
with that of Section 05100-Structural Steel Framing;
Section 05200-Steel Joists.
1.03 Reference Standards for Quality Assurance
A. Codes/Standards- The work and materials of this
section shall comply with:
1. Section properties shall be derived in accordance
with AISI "Specification for Design of
Cold-Formed Steel Structural Members, Latest
Edition."
2. Metal decking is to be attached to the
structural frame in conformance with AWS
D1.1 and D1.3 "Specification for Welding
Sheet Steel in Structures."
3. ICC Evaluation Service Report No. 1414
* Note to Specifier:
Insert the appropriate L.A. City Research Report
No. when applicable, 23783, 23784.
4. ASTM reference numbers:
(a) ASTM A653, Steel Sheet, Zinc-Coated
(Galvanized) or Zinc-Iron alloy-coated (Galvannealed)
By The Hot-Dip Process,
Structural (Physical) Quality.
5. Steel Deck Institute (SDI)-Metal floor deck
profiles shall be in conformance with SDI
standards.
1.04 Submittals
A. Shop Drawings
1. Prior to fabrication; prepare shop drawings for
work under this section and submit to Architect.
Shop drawings are to include deck layout, framing and support of openings, layout and quality
of studs on beams, dimensions and sections,
details of accessories and type and location of
welds.
2. Manufacturer's product literature and relevant
approvals are to be submitted with the shop
drawings.
3. Where metal decking is part of a fire rated
assembly, the metal deck manufacturer shall
provide all data to insure compliance with the
UL design number and with ICBO.

62

1.05 Product Handling


A. Metal deck
Transport, store and erect metal deck and its
accessories in a manner that will prevent corrosion,
deformation or other damage. Store deck clear of
the ground with one end elevated to promote
drainage; protect metal deck from water and the
elements with a water resistant material. Do not use
as a storage platform.
Part 2 - Products
2.01 Materials and Finishes
A. Metal floor deck to be ASC Steel Deck
[select appropriate profile(s) and gauge(s).]
1. B-36, (22,20,18,16) gauge,
1 1/2" deep x 36" wide.
2. N-24 (22,20,18,16) gauge, 3" deep x 24" wide.
3. 2W-36 (22,21,20,19,18,16) gauge, 2 1/8" deep x
36"wide.
4. 3W-36 (22,21,20,19,18,16) gauge, 3" deep x
36"wide.
5. ASC2 or ASC3 (20/20, 20/18, 20/16, 18/20,
18/18, 18/16, 16/16, 3" deep x 24" wide.
6. BF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16,
16/16) gauge; 1 1/2 deep x 36 wide.
7. NF-24 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16,
16/16) gauge; 3 deep x 24 wide.
8. 2WF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16,
16/16)gauge; 2 1/8 deep x 36 wide.
9. 3WF-36 (20/20, 20/18, 20/16, 18/20, 18/18, 18/16,
16/16) gauge; 3 deep x 36 wide.
Deck units are to be fabricated from sheet steel
conforming to ASTM A653, Fy = 38 KSI with a
galvanized coating, (select appropriate coating)
G-60, G-90.
*Note to Specifier:
2W-36, 3W-36, 2WF-36 and 3WF-36 are available in 24" wide
panels; when specified, the designations are 2W-24, 3W-24, 2WF24 and 3WF-24.
*Note to Specifier: When specifying CF-1/2, CF-7/8 or CF-1 3/8,
use the following:
1. CF-7/8 (26,24,22,20) gauge, 7/8" deep.
2. CF-1 3/8 (26,24,22,20,18) gauge, 1 3/8" deep.
Deck units are to fabricated from sheet steel conforming to ASTM
A653, Structural Grade E (26, 24, 22, 20 ga) with a galvanized
coating, G-90. CF 1 3/8 (18 ga) is to be fabricated from sheet steel
conforming to ASTM A653, Fy = 38 KSI with a galvanized coating,
G-90.
*Note to Specifier: When specifying Deep Deck, use the following:
1. Deep Deck (20, 18, 16, 14) gauge; 4 1/2, 6 or
7 1/2 deep deck x 12 wide.
Deck units are to be fabricated from sheet steel conforming to
ASTM A653, Fy=33KSI with a galvanized coating.

ASC Steel Deck

Composite Floor Deck Specifications


2.02 Fabrication
A. Metal Deck
Manufacture deck units to lengths as indicated on
shop drawings. Panel end conditions are to be
butted. Sidelaps are to be male/female interlocking
type, suitable for button punching.
*Note to specifier: When specifying CF-7/8 or CF-1 3/8 delete the
last sentence and insert:
Sidelaps are to be overlapping type.
B. Accessories
Fabricate steel deck accessories from the same
gauge and material as adjacent steel deck.
Part 3 - Execution
3.01 Inspection
A. Examine the areas and conditions under which the
work of this Section is to be performed. Correct any
conditions which are detrimental to the timely and
proper completion of the work of this Section. Do not
proceed with work until unsatisfactory conditions are
corrected.
The General Contractor shall be responsible for
obtaining coupons, randomly selected from the steel
deck delivered to the job site. These coupons shall be
tested by an independent lab to verify that the base
metal thickness is within 95% of the deck
manufacturer's published design t.

supporting members and accurate alignment of endlaps and sidelaps prior to permanently attaching units.
C. Attachment of Metal Deck Units
Welded attachment of metal deck units to the
supporting members shall conform to AWS D1.1
and D1.3.
Welders shall be certified prior to commencing work.
Attach metal deck units to supporting members with 1/2" effective
diameter puddle welds.
* Note to Specifier: When specifying CF-7/8 or CF-1 3/8 (24 and
26 gauges only) delete the second paragraph and insert:
Attach metal deck units to supporting members with plug welds
using a 14-gauge weld washer having a 3/8" diameter hole and
(when attachment method requires) a 16-gauge anchor washer
having a 7/16" diameter hole.
Welds to supporting members and the method of sidelap attachment are to be as per the structural drawings.

3.02 Installation
A. General
Install the metal deck and accessories in compliance
with the manufacturer's written recommendations and
approved shop drawings.
B. Placing Metal Deck Units.
Place metal deck units on supporting members and
adjust to proper position. Ensure proper bearing on

Effective January 2008

Preformed Metal Deck 63

Preformed Metal Floor Deck

Materials and Finishes


The B, N, 2W, 2WF, ASC2, ASC3, 3W and 3WF
profiles are manufactured from steel conforming to ASTM
A653 (Fy=38ksi). CF profiles are manufactured from steel
conforming to ASTM A653 (Grade E), except CF 1 3/8 (18 ga)
which is manufactured from steel conforming to ASTM A653
(Fy=38ksi).
The standard galvanized coatings are G-60 (.60 oz./ft2)
or G-90 (.90 oz./ft.2) in accordance with ASTM A653. The
B, 2W, 2WF, 3W, 3WF ASC2 & ASC3 are available in
G-60 and G-90. The CF profiles are available in G-90.
Please inquire for the availability of alternate coatings.
Please Note: spot weld discoloration will not be a reason
for rejection of cellular deck.
The cellular decking listed in this catalog is manufactured from two sections of galvanized steel that are joined
with resistance welds. The deck coating and finish will
be removed, from the area of the resistance weld, during
this process. This condition should be considered when
determining the fitness of this product for a specific
application. This condition will also not be an acceptable
cause for rejection of the material. Please contact your
ASC Steel Deck representative for additional
information on this subject.

64

ASC Steel Deck reserves the right to make revisions in the


design and/or specifications of our products without prior notice.
Dimensions and specifications of products are subject to normal
manufacturing tolerances. Consult factory concerning availability
of product.
The information in this brochure is, to the best of our
knowledge, accurate. However, no information, representation nor
formula contained herein is designed to replace the judgement of
an experienced structural engineer or other professional designer.
ASC Steel Deck assumes no liability whatsoever for the accuracy
or completeness of the information contained in this brochure, nor
for the suitability of the material for its intended purpose.

ASC Steel Deck


1-800-726-2727

ASC Steel Deck

Metric Conversion Chart

Metric Conversions
Spans, Length and Thickness

Vertical Load and Superimposed Load


Area
Diaphragm Shear
Section Properties

Weight
Volume

Effective January 2008

Multiply

By

To Obtain

Inches
Feet
Inches
Feet
psf
psi
Square feet
Square
plf
in3/ft
in4/ft
in3/ft
in4/ft
Pounds
psf
pcf

25.4
304.8
0.0254
0.3048
0.0479
6.8948
0.0929
9.2903
0.0146
53,763
1,365,588
53.763
136.559
0.00445
4.8824
16.018

Millimetres
Millimetres
Metres
Metres
kPa
kPa
Square Metre
Square Metre
KN/m
mm3/m
mm4/m
cm3/m
cm4/m
kN
kg/m2
kg/m3

Preformed Metal Deck 65

Vous aimerez peut-être aussi