Vous êtes sur la page 1sur 13

Installation

Instruction
Code No. 0816672
Rev.2 (07/15)

AER-DEC-81000/82000/83000/84000
Integrated Sink System
Single/Double/Triple/Quadruple Station Corian or Quartz Lavatory Systems

AD-81000
Deck Sink Lavatory System

AD-82000
Deck Sink Lavatory System

AD-83000
Deck Sink Lavatory System

AD-84000
Deck Sink Lavatory System

Corian/Quartz (Pages 2-3)

Corian/Quartz (Pages 4-5)

Corian/Quartz (Pages 6-7)

Corian/Quartz (Pages 8-9)

IMPORTANT
Read this entire installation manual to ensure proper installation.
When finished with the installation, file this manual with the owner
or maintenance department. Compliance and conformity to local
codes and ordinances is the responsibility of the installers.
Separate parts from packaging and make sure all parts are
accounted for before discarding any packaging material. If any
parts are missing, do not begin installation until you obtain the
missing parts.
Make sure that all water supply lines have been flushed and then
completely turned off before beginning installation. Debris in supply
lines can cause valves to malfunction.

Turn OFF electrical power to the electrical outlets, then unplug all
electrical units prior to installation. Electrical power MUST remain
off until installation is complete.
Installers hardware must be appropriate for wall construction. Wall
anchors must have a minimum pull-out rating of 1,000 lbs.
For standard height mounting, do not exceed the recommended
34 distance from the top of the lav deck to the finished floor. To
meet ADA requirements, the lav deck cannot exceed the
34 maximum height dimension.
Wear all proper safety equipment prior to installation.

PRIOR TO INSTALLATION
Important:
Adequate structural support in or behind the wall is required. Refer to the
appropriate rough-in diagram for dry weight of sink.
Refer to pages 10 and 11 for sink and stud support requirements.

All plumbing should be installed in accordance with applicable


codes and regulations.
Before connecting flex hoses to supply stops, flush all water lines until
water is clear.
Hot and cold water supply lines/tempered supply line and drain lines.

SUPPLIES REQUIRED FOR INSTALLATION OF SINKS


3/8 x 2 1/2 lag screws, wall anchors, bolts (minimum pull-out rating of
1000 Ibs./450 kg). See Frame Mounting Support drawing for required lag
screws for your specific lavatory system.
1/2 NPT hot/cold or tempered supply piping
1 1/2 NPT drain piping including p-trap

Adhesive: Loctite PL Premium FAST GRAB Polyurethane Construction


Adhesive
110 volt GFCI protected electrical outlet for 100-120 VAC plug-in transformer
Screen filter(s) included with faucet(s)
Backing supplied by others to meet local codes

LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants its Products to be made of first class materials, free from defects of material or workmanship under normal use and to
perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for SF Faucets, special finishes and PWT electronics and 30 days on PWT software) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace
any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customers cost, and this shall be the sole remedy available under this warranty. No
claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Companys products
directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR
ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW SINGLE STATION


30
Muffler with 2
Hand Dryer Motor
Hose (Overall 56 3/4)

Drain
clean-out

Fasten Frame to 1/8


thick steel strapping
or backing material

Hot
water
supply
34

22
backing
material

21
frame 2
33 to top
of frame
6 1/4 x 9 1/4 x 7.63
Soap Reservior

1/2 or 5/8
x 30 x 22
backing material
3/4 (not supplied)
securely fasten to
studs

Cold water supply

HAND DRYER MOTOR


12.5 x 11.4 x 12.4 deep

Finished Floor

NOTES:
1. Mount Hand Dryer Motor Hose and soap dispenser to spec. location
2. Slip frame over mounted components and properly fasten frame to
backing material

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW SINGLE STATION
(1) GFI Receptacle for soap
& sensor faucets, Transformer
Plug 120V/20AMP required by
National Electrical Code

(1) Hand dryer


GFI Receptacle
120V/20AMP
Standard 3 x 5
duplex receptacles
per sink manufacturer
requirements

30

Fasten frame to
1/8 thick steel
strapping or backing
material
4

33 to top
of frame

Hot
water
supply

7 1/2

Soap
Reservior

26
Water Supplies
30 Basin
ONLY
Cold Water Supply

Hand dryer
motor
mounting
plate

34
23
A.F.F.

19
Drain

Finished Floor

NOTES:
1. Hand Dryer Motor alone is only 500 watts or less with speed control
2. Hand Dryer Motor with heater requires 1500 watts or less with speed control
3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit
4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug
5. cut backing to allow for electrical and plumbing components
ROUGH-IN PLUMBING & ELECTRICAL

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW SINGLE STATION


Drywall
23 1/2
23
22 to end of frame
Sloan BASYS
Mid Faucet

Sloan BASYS
Hand Dryer Spout
(patent applied for)
1/2 Solid surface
1/2 Backing Material
1/4 x 4 Steel plate
Vented basin design
(patent applied for)
Drain box & clean out
(patent applied for)
6 Max.

Optional aluminum
C-Channel w/LEDs
inside tract (120 volt
transformer required)
Stainless steel
34
access door
hangs on
27
rectangular
tubing frame
Push button latches snap
into place inside tubing
Finished Floor

3
1/2
1

Air dam
(patent applied for)

Muffler (patent applied for)

5 1/2
3/4

7 1/4
8 min.
16 1/8
Access
panel

Trough 1 deep at start of trough


3/4 width at bottom of trough
2 Hand Dryer Motor Hose (overall 56 3/4)
Electrical outlet boxes (not supplied)
Standard 3 x 5 duplex GFI receptacles
Hand dryers - 120V/20Amp
Faucets/Soap - 120V/15Amp

Backing material (required)


(not supplied)

11 1/8

11
6 max.
9

Drywall
17 min.

Sloan Foam Soap Dispenser


1/2 Backing material

20 23
Water A.F.F.
Supplies

12 to
19 drain
bottom
of frame 14
to bottom
NOTE:
of Dryer
1. Backing material
Mounting
should equal thickness
Plate
of drywall (1/2 min.)
Hand
Dryer
Motor

21
frame

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW SINGLE STATION


4 1/2 2 6 1/2

Sloan BASYS
Mid Faucet Spout

8 1/2

Sloan BASYS
Hand Dryer

5 3/8
Drain w/clean-out
GRID STRAINER TO BE CLEANED
OUT AS REQUIRED

3/4
23 1/2
Sloan Foam
Soap Dispenser

1/2 Solid Surface


1

1/2

Air Dam Vent

1 3/4
21
30

4 1/2

4 1/2

DRAIN ASSEMBLY AND FRAME ENCLOSURE MOUNTING SUPPORT SINGLE STATION


Drywall
Backing (supplied by others)
to meet local codes

Wood Stud per schedule

GFI 4 gang outlet


(not supplied)

2x10 wood
reinforcement
between studs

Hand Dryer Motor


w/ Muffler
Frame
Attachment
Enclosure

1. Measure outside of frame.


Cut-out drywall window.
2. Remove drywall window.
3. Replace with backing supplied
by others (per local code).
4. Using mounting template,
mount hand dryer motor, Soap
Dispenser
Pump (optional) and electrical
outlets to backing.

33"

*Due to manufacturing
tolerances, all dimensions
are for reference only.

Soap Reservior

Lag Bolts

5. Mount top of frame at 33 above


finished floor.
6. Securely fasten with 1,000 Lb
pull out lag bolts.
7. Attach access panel to frame.
12

12
6

*Hole Location for


Mounting Frame

12

12

Access Panel

MOUNTING FAUCETS, SOAP DISPENSERS & HAND DRYERS / ATTACHING DECK TO FRAME ENCLOSURE SINGLE STATION

Adhesive

BASYS DRYER
SPOUT SUBASSEMBLY

HOLDING NUT
ASSEMBLY

FRAME SUPPORT
1. Back edge of Deck may require scribing to finished wall.
2. Shim all gaps between frame and deck,
especialy under trough area.

CONNECT CONTROL
CABLE TO HAND DRYER
MOTOR

EHD-510

1. For ease of installation, leave the


deck laying on its back. Install
faucets, optional soap dispensers and hand dryers according
to manufacturers instructions.
2. Hook-up hand dryer motor hose
to hand dryer motors. Do not
connect power until air spout is
completely installed.
3. Install all water connections,
drain lines and components.
ESD-400
BASYS SOAP SPOUT
SUBASSEMBLY

HAND DRYER MOTOR


HOSE & MUFFLER

BAYONET TURN
TO LOCK HOSE
TO SPOUT

PROGRAMING
CABLE. LEAVE
UNATTACHED

HOLDING NUT
ASSEMBLY

CONNECT GROUND
WIRE TO HAND
DRYER MOTOR

SOAP DISPENSER
LINES

POWER ADAPTOR

BAYONET TURN
TO LOCK HOSE TO
HAND DRYER MOTOR

HAND DRYER/SOAP DISPENSER


Refer to installation instructions with
component.

HAND DRYER MOTOR

SOAP DISPENSER
MOTOR ASSEMBLY

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW DOUBLE STATION


60
Drain clean-out
18

Brace

Muffler with 2 Hand Dryer Motor


Hose (Overall 56 3/4)
18
Fasten frame to
1/8 thick steel
strapping or backing
(not supplied)

Brace

11 1/2

22
Backing

21
frame
34

33
to top
of frame

1/2 or 5/8 x 60 x 22 backing


securely fasten to studs
6 1/4 x 9 1/4 x 7.63
Soap Reserviors

Cold water supply


Hot water supply

Hand Dryer Motor


Finished floor
12.5 x 11.4 x 12.4 deep
NOTES:
1. Mount hand dryer motor & soap dispenser
to spec location
2. Slip frame over mounted components
& properly fasten frame to backed wall
3. Hot & Cold water supply lines location
subject to local code

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW DOUBLE STATION
60

(2) GFI Receptacle for soap


& sensor faucets, transformer
plug 120V/20AMP required by
national electrical code

Hand dryer
motor
mounting
plate

33 to
34 top of frame

10 3/4
Soap
Reservior

(2) Hand dryer motor


GFI Receptacle
120V/20AMP

9 1/4
11 1/2
6

Soap
Reservior

20
5
water
supplies Hot
water
supply

Cold
water
supply

Fasten frame to
1/8 thick steel
strapping or backing
material

Standard 3 x 5
duplex receptacles
per sink manufacturer
requirements

Hand dryer
motor
mounting
plate
23
A.F.F.
Finished floor

NOTES:
1. Hand Dryer Motor alone is only 500 watts or less with speed control
2. Hand Dryer Motor with heater requires 1500 watts or less with speed control
3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit
4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug
5. cut backing to allow for electrical and plumbing components
ROUGH-IN PLUMBING & ELECTRICAL

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW DOUBLE STATION


Drywall
23 1/2
23
22 to end of frame
Sloan BASYS
Mid Faucet

Sloan BASYS
Hand Dryer Spout
(patent applied for)
1/2 Solid surface
1/2 Backing Material
1/4 x 4 Steel plate
Vented basin design
(patent applied for)
Drain box & clean out
(patent applied for)
6 Max.

Optional aluminum
C-Channel w/LEDs
inside tract (120 volt
transformer required)
Stainless steel
34
access door
hangs on
27
rectangular
tubing frame
Push button latches snap
into place inside tubing
Finished Floor

3
1/2
1

Air dam
(patent applied for)

Muffler (patent applied for)

5 1/2
3/4

7 1/4
8 min.
16 1/8
Access
panel

Trough 1 deep at start of trough


3/4 width at bottom of trough
2 Hand Dryer Motor Hose (overall 56 3/4)
Electrical outlet boxes (not supplied)
Standard 3 x 5 duplex GFI receptacles
Hand dryers - 120V/20Amp
Faucets/Soap - 120V/15Amp

Backing material (required)


(not supplied)

11 1/8

11
6 max.
9

Drywall
17 min.

Sloan Foam Soap Dispenser


1/2 Backing material

20 23
Water A.F.F.
Supplies

12 to
19 drain
bottom
14
of frame
to bottom
NOTE:
of Dryer
1. Backing material
Mounting
should equal thickness
Plate
of drywall (1/2 min.)
Hand
Dryer
Motor

21
frame

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW DOUBLE STATION


32
7 1/2

6 1/2

8 1/2

6 1/2

7 1/2

Sloan BASYS
Hand Dryer

7 1/2

Sloan BASYS
Mid Faucet
Sloan Foam
soap dispensers

5 3/8
3/4

Drain w/clean-out
Grid strainer to be cleaned
out as required

23 1/2
1/2

1/2 Solid surface

Air dam/vent

1 3/4
4 1/2

51
60

4 1/2

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT DOUBLE STATION


4. Using mounting template, mount
1. Measure outside of frame.
hand dryer motor, soap dispenser
Cut-out drywall window
pump (optional) and electrical outlets
2. Remove drywall window.
GFI 4 gang outlet
3. Replace with backing supplied by to backing.
Soap Reservior
5. Mount top of frame at 33 above
others (per local code).
Hand Dryer Motor
finished floor.
w/ Muffler Attachment Frame Enclosure
6. Securely fasten with 1,000 Lb
Lag Bolts
pull out lag bolts.
Wood Screws
7. Attach access panel to frame.

Drywall
Backing supplied by others
to meet local codes

Wood Stud per schedule


2x10 wood
reinforcement
between studs

12

12

12

12

33"

*Hole Location for


Mounting Frame
*Due to manufacturing
tolerances, all dimensions
are for reference only.

Access Panel

12

12

MOUNTING FAUCETS / ATTACHING DECK TO FRAME DOUBLE STATION


1. For ease of installation, leave the
deck laying on its back. Install
faucets, optional soap dispensers and hand dryers according
to manufacturers instructions.
2. Hook-up hand dryer motor hose
to hand dryer motors. Do not
connect power until air spout is
completely installed.
3. Install all water connections,
drain lines and components.

Adhesive

Adhesive
FRAME SUPPORT
1. Back edge of Deck may require scribing
to finished wall.
2. Shim all gaps between frame and deck,
especially under trough area.

BASYS DRYER
SPOUT SUBASSEMBLY

HOLDING NUT
ASSEMBLY

CONNECT CONTROL
CABLE TO HAND DRYER
MOTOR

EHD-510

BASYS SOAP SPOUT


SUBASSEMBLY

ESD-400

HAND DRYER MOTOR


HOSE & MUFFLER

BAYONET TURN
TO LOCK HOSE
TO SPOUT

HOLDING NUT
ASSEMBLY

PROGRAMING
CABLE. LEAVE
UNATTACHED
CONNECT GROUND
WIRE TO HAND
DRYER MOTOR

SOAP DISPENSER
LINES

POWER ADAPTOR

BAYONET TURN
TO LOCK HOSE TO
HAND DRYER MOTOR

HAND DRYER/SOAP DISPENSER


Refer to installation instructions with
component.

HAND DRYER MOTOR

SOAP DISPENSER
MOTOR ASSEMBLY

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW TRIPLE STATION


90

30
Drain clean-outs

Brace

Brace

Fasten frame to
1/8 thick steel
strapping or backing
(not supplied)
22
Backing

21
frame
34

30
Muffler with 2
hand dryer motor hose

Soap
Reservior

33
to top
of frame

Soap
Reservior

Soap
Reservior

Hand Dryer Motor


12.5 x 11.4 x 12.4 deep

OPTIONAL Cold
water supply

Cold water supply

1/2 or 5/8 x 60 x 22 backing


securely fasten to studs

OPTIONAL Hot
water supply

Hot water supply Finished Floor

6 1/4 x 9 1/4 x 7.63


Soap Reserviors

NOTES:
1. Mount hand dryer motor & soap dispenser to spec location
2. Slip frame over mounted components & properly
fasten frame to backed wall
3. Hot & Cold water supply lines location subject
to local code

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW TRIPLE STATION
(3) Hand dryer motor
GFI Receptacle
120V/20AMP

90

(3) GFI Receptacle for soap


& sensor faucets, transformer
plug 120V/20AMP required by
national electrical code

Standard 3 x 5
duplex receptacles
per sink manufacturer
requirements
6 5/8

34 33 to
top of
frame

Hand dryer
motor mounting
plate

23
A.F.F.

4 1/4

Soap
Reservior

Soap
Hand dryer
Reservior motor mounting
plate

19
Drains

11 1/2

Cold
water
Hot supply 20
water supplies
water
supply

OPTIONAL Hot
water supply

2 7/8

Hand dryer
Soap
Reserviormotor mounting
plate

Fasten frame to
1/8 thick steel
strapping or backing
material (not supplied)

OPTIONAL Cold
water supply
Finished Floor

NOTES:
1.Hand Dryer Motor alone is only 500 watts or less with speed control
2. Hand Dryer Motor with heater requires 1500 watts or less with speed control
3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit
4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug
5. cut backing to allow for electrical and plumbing components
ROUGH-IN PLUMBING & ELECTRICAL

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW TRIPLE STATION


Drywall
23 1/2
23
22 to end of frame
Sloan BASYS
Mid Faucet

Sloan BASYS
Hand Dryer Spout
(patent applied for)
1/2 Solid surface
1/2 Backing Material
1/4 x 4 Steel plate
Vented basin design
(patent applied for)
Drain box & clean out
(patent applied for)
6 Max.

Optional aluminum
C-Channel w/LEDs
inside tract (120 volt
transformer required)
Stainless steel
34
access door
hangs on
27
rectangular
tubing frame
Push button latches snap
into place inside tubing
Finished Floor

3
1/2
1

Air dam
(patent applied for)

Muffler (patent applied for)

5 1/2
3/4

7 1/4
8 min.
16 1/8
Access
panel

Trough 1 deep at start of trough


3/4 width at bottom of trough
2 Hand Dryer Motor Hose (overall 56 3/4)
Electrical outlet boxes (not supplied)
Standard 3 x 5 duplex GFI receptacles
Hand dryers - 120V/20Amp
Faucets/Soap - 120V/15Amp

Backing material (required)


(not supplied)

11 1/8

11
6 max.
9

Drywall
17 min.

Sloan Foam Soap Dispenser


1/2 Backing material

20 23
Water A.F.F.
Supplies

12 to
19 drain
bottom
14
of frame
to bottom
NOTE:
of Dryer
1. Backing material
Mounting
should equal thickness
Plate
of drywall (1/2 min.)
Hand
Dryer
Motor

21
frame

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW TRIPLE STATION


7 1/2 6 1/2

31

8 1/2

8 1/2

31

6 1/2

Sloan BASYS
Hand Dryer

6 1/2 7 1/2

8 1/2

Sloan BASYS
Mid Faucet
Sloan Foam
Soap Dispensers

5 3/8
3/4

Drain w/clean-out
Grid strainer to be cleaned
out as required

High Point
23 1/2

1/2 Solid surface


Air dam/vent
3

1 3/4

81
90

4 1/2

4 1/2

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT TRIPLE STATION


2x10 Wood
Reinforcement
in between studs
(See page 10 for
steel stud
installation
requirements)

Steel/Wood Stud
2x4 or 2x6
(See page 10 for
steel stud installation
requirements)

Drywall

Backing supplied by
others to meet local codes
Hand Dryer Motor
w/ Muffler Attachment
Soap Reservior
Frame
Lag Bolts
Enclosure

4. Using mounting template, mount


1. Measure outside of frame.
hand dryer motor, soap dispenser
Cut-out drywall window
pump (optional) and electrical outlets
2. Remove drywall window.
to backing.
3. Replace with backing supplied by
5. Mount top of frame at 33 above
others (per local code).
finished floor.
6. Securely fasten with 1,000 Lb
pull out lag bolts.
7. Attach access panel to frame.
12

12

12

12

12

12

12
6

33

*Hole Location for


Mounting Frame

Access
Panels (2)

*Due to manufacturing
tolerances, all dimensions
are for reference only.
12

12

12

MOUNTING FAUCETS / ATTACHING DECK TO FRAME TRIPLE STATION


1. For ease of installation, leave the
deck laying on its back. Install
faucets, optional soap dispensers and hand dryers according
to manufacturers instructions.
2. Hook-up hand dryer motor hose
to hand dryer motors. Do not
connect power until air spout is
completely installed.
3. Install all water connections,
drain lines and components.

Adhesive

BASYS DRYER
SPOUT SUBASSEMBLY

FRAME SUPPORT
1. Back edge of Deck may require scribing
to finished wall.
2. Shim all gaps between frame and deck,
especialy under trough area.

HOLDING NUT
ASSEMBLY

CONNECT CONTROL
CABLE TO HAND DRYER
MOTOR

EHD-510

BASYS SOAP SPOUT


SUBASSEMBLY

ESD-400

HAND DRYER MOTOR


HOSE & MUFFLER

BAYONET TURN
TO LOCK HOSE
TO SPOUT

HOLDING NUT
ASSEMBLY

PROGRAMING
CABLE. LEAVE
UNATTACHED
CONNECT GROUND
WIRE TO HAND
DRYER MOTOR

SOAP DISPENSER
LINES

POWER ADAPTOR

BAYONET TURN
TO LOCK HOSE TO
HAND DRYER MOTOR

HAND DRYER/SOAP DISPENSER


Refer to installation instructions with
component.

HAND DRYER MOTOR

SOAP DISPENSER
MOTOR ASSEMBLY

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW QUADRUPLE STATION


120

29

Drain clean-outs

Brace

21 3/4

16 3/8
21
frame

Fasten frame to
1/8 thick steel
strapping or backing

Brace

9 1/4

Soap
Reservior

34

Muffler with 2
hand dryer motor hose

29

9 1/4

20 5/8

22
Backing
33
to top
of frame

Soap
Reservior

Soap
Reservior

Soap
Reservior

16 3/8

Cold water supply


Cold water supply 1/2 or 5/8 x 60 x 22
Hot water supply
3 1/2 12 to
backing
securely
fasten
bottom of Hot water supply
6 1/4 x 9 1/4 x 7.63 Hand dryer motor
frame
Finished floor
to studs
deep soap reserviors
12.5 x 11.4 x 12.4 deep
NOTES:
1. Mount hand dryer motor & soap dispenser to spec location
2. Slip frame over mounted components & properly
fasten frame to backed wall
3. Hot & Cold water supply lines location subject
to local code

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW QUADRUPLE STATION
(4) Hand dryer
GFI Receptacle
120V/20AMP
Standard 3 x 5duplex
receptacles per sink
manufacturer requirements
7 7/8

34

(4) GFI Receptacle for soap


& sensor faucets, transformer
plug 120V/20AMP required by
National Electrical Code

120

11

Soap
Hand dryer
motor mounting Reservior
plate

8
Soap
Reservior

10 7/8
Soap

Hot
water
supply

23
A.F.F.

Soap
Reservior

Hand Dryer
Hand Dryer
6
Reservior
motor mounting motor mounting
plate
plate

Cold
Hot
water
water supply
supply

20
water
supplies

14

19
Drains

Cold
water
supply

12 3/8
Hand dryer
motor mounting
plate

Fasten frame to
1/8 thick steel
strapping or backing
material (not supplied)

33 to
top of frame

Finished Floor

NOTES:
1. Hand Dryer Motor alone is only 500 watts or less with speed control
2. Hand Dryer Motor with heater requires 1500 watts or less with speed control
3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit
4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug
5. cut backing to allow for electrical and plumbing components
ROUGH-IN PLUMBING & ELECTRICAL

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW QUADRUPLE STATION


Drywall
23 1/2
23
22 to end of frame
Sloan BASYS
Mid Faucet

Sloan BASYS
Hand Dryer Spout
(patent applied for)
1/2 Solid surface
1/2 Backing Material
1/4 x 4 Steel plate
Vented basin design
(patent applied for)
Drain box & clean out
(patent applied for)
6 Max.

Optional aluminum
C-Channel w/LEDs
inside tract (120 volt
transformer required)
Stainless steel
34
access door
hangs on
27
rectangular
tubing frame
Push button latches snap
into place inside tubing
Finished Floor

3
1/2
1

Air dam
(patent applied for)

Muffler (patent applied for)

5 1/2
3/4

7 1/4
8 min.
16 1/8
Access
panel

Trough 1 deep at start of trough


3/4 width at bottom of trough
2 Hand Dryer Motor Hose (overall 56 3/4)
Electrical outlet boxes (not supplied)
Standard 3 x 5 duplex GFI receptacles
Hand dryers - 120V/20Amp
Faucets/Soap - 120V/15Amp

Backing material (required)


(not supplied)

11 1/8

11
6 max.
9

Drywall
17 min.

Sloan Foam Soap Dispenser


1/2 Backing material

20 23
Water A.F.F.
Supplies

12 to
19 drain
bottom
14
of frame
to bottom
NOTE:
of Dryer
1. Backing material
Mounting
should equal thickness
Plate
of drywall (1/2 min.)
Hand
Dryer
Motor

21
frame

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW QUADRUPLE STATION

6 1/2 8 1/2

31

31

31

6 1/2

Sloan BASYS
Hand Dryer
Sloan BASYS
Mid Faucet
Sloan Foam
Soap Dispensers

3/4
23 1/2
Drain w/clean-out
Grid strainer to be cleaned
out as required

Drain w/clean-out
Grid strainer to be cleaned
out as required

1 3/4

1/2 Solid surface


Air Dam/Vent
1/2

111
120

4 1/2

4 1/2

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT QUADRUPLE STATION


2x10 Wood
Reinforcement
in between studs
(See page 10 for
steel stud
installation
requirements)

Steel/Wood Stud
2x4 or 2x6
(See page 10 for steel
stud installation
requirements)

Drywall

Backing supplied by others


to meet local codes

Hand Dryer Motor


w/ Muffler Attachment
Soap Reservior

Lag Bolts
Frame Enclosure

4. Using mounting template, mount


1. Measure outside of frame.
hand dryer motor, soap dispenser
Cut-out drywall window
pump (optional) and electrical outlets
2. Remove drywall window.
3. Replace with backing supplied by to backing.
5. Mount top of frame at 33 above
others (per local code).
finished floor.
6. Securely fasten with 1,000 Lb
pull out lag bolts.
7. Attach access panel to frame.
12

12

12

12

12

12

12

12
6

33

*Hole Location for


Mounting Frame

Access
Panels (2)

*Due to manufacturing
tolerances, all dimensions
are for reference only.
12

12

12

12

12

12

MOUNTING FAUCETS / ATTACHING DECK TO FRAME QUADRUPLE STATION


1. For ease of installation, leave the
deck laying on its back. Install
faucets, optional soap dispensers and hand dryers according
to manufacturers instructions.
2. Hook-up hand dryer motor hose
to hand dryer motors. Do not
connect power until air spout is
completely installed.
3. Install all water connections,
drain lines and components.

Adhesive

FRAME SUPPORT
1. Back edge of Deck may require scribing to
finished wall.
2. Shim all gaps between frame and deck,
especialy under trough area.

BASYS DRYER
SPOUT SUBASSEMBLY

HOLDING NUT
ASSEMBLY

CONNECT CONTROL
CABLE TO HAND DRYER
MOTOR

EHD-510

BASYS SOAP SPOUT


SUBASSEMBLY

ESD-400

HAND DRYER MOTOR


HOSE & MUFFLER

BAYONET TURN
TO LOCK HOSE
TO SPOUT

HOLDING NUT
ASSEMBLY

PROGRAMING
CABLE. LEAVE
UNATTACHED
CONNECT GROUND
WIRE TO HAND
DRYER MOTOR

SOAP DISPENSER
LINES

POWER ADAPTOR

BAYONET TURN
TO LOCK HOSE TO
HAND DRYER MOTOR

HAND DRYER/SOAP DISPENSER


Refer to installation instructions with
component.

HAND DRYER MOTOR

SOAP DISPENSER
MOTOR ASSEMBLY

SINK BRACKET STUD SUPPORT

COLD FORMED STEEL FRAME MOUNTING SUPPORT

Metal Stud per schedule

Drywall

5 - 18 gauge
stud reinforcement
between studs

Backing supplied
by others to meet
local codes

Corian Sink Design Requirements:


Max. sink deck depth = 25
Max. sink dead weight (including stone and fixture = 10 psf
Max. concentrated live load at edge of sink = 500lbs.
Provide anchor spacing noted within product drawings
Cold Formed Steel Framing for AD
Series Corian Sinks
Wall/Stud
Height

Flange

Min.
Gauge

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

14
16
16
18
18
18
18
18
16

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

14
16
16
16
16
18
18
18
16

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

12
16
16
16
16
18
18
18
16

3-5/8

1-3/8
1-5/8
2
2-1/2

14
14
16
16

1-5/8
2
2-1/2
3

16
18
18
16

1-3/8
1-5/8
2
2-1/2
1-5/8
2
2-1/2
3

12
12
16
12
16
18
18
16

1-5/8
2
2-1/2
3
2
2-1/2
3

12
14
16
16
18
18
16

Depth

3-5/8

Sink Length

42"

10
6

2"
Sink System
Enclosure

35"
Drywall

3-5/8

12
6

3-5/8

14
WOOD FRAME MOUNTING SUPPORT

6
Drywall

Wood Stud per schedule

Backing supplied
by others to meet
local codes

2x10 wood
reinforcement
between studs

16
Sink Length

2'

42"

Sink System
Enclosure

35"

3-5/8
Drywall

18
6

3-5/8
20
6

10

Wood Framing for AD Series Corian


Sinks
Wall/
Studs Req.
Stud Stud @16 o.c. Species
Height
(See Note 1)

10

2x4
2x6

2
1

12

2x4
2x6

3
1

14

2x4
2x6

3
1

16

2x4
2x6

3
1

18

2x4
2x6

3
1

20

2x4
2x6

3
2

SPF

Grade

No. 2

Note 1: Where mutiple studs are listed, bunch


multiple studs and space multiple studs @16
o.c. across width of sink

CLEANING AND MAINTENANCE


Material Description: Corian Material is made from a blend of acrylic
modified bio-based polyester resin. Engineered Stone is 90% natural quartz
and polyester resin and is resistant to chemicals, stains, burns and impact.
Surface damage can be easily repaired with everyday cleansers or fine grit
abrasives.

Quartz Sink Design Requirements:


Max. sink deck depth = 25
Max. sink dead weight (including stone and fixture = 20 psf
Max. concentrated live load at edge of sink = 500lbs.
Provide anchor spacing noted within product drawings
Cold Formed Steel Framing for AD
Series Corian Sinks
Wall/Stud
Height

Depth

3-5/8

10
6

3-5/8

12
6

3-5/8

14
6

3-5/8
16
6

3-5/8
18
6

3-5/8
20
6

Flange

Min.
Gauge

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

14
16
16
18
18
18
18
18
16

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

14
16
16
16
16
18
18
18
16

1-3/8
1-5/8
2
2-1/2
1-3/8
1-5/8
2
2-1/2
3

12
16
16
16
16
18
18
18
16

1-3/8
1-5/8
2
2-1/2
1-5/8
2
2-1/2
3

14
14
16
16
16
18
18
16

1-3/8
1-5/8
2
2-1/2
1-5/8
2
2-1/2
3

12
12
16
12
16
18
18
16

1-5/8
2
2-1/2
3
2
2-1/2
3

12
14
16
16
18
18
16

Routine Cleaning: For regular cleaning, use standard commercial or


household products such as Simple Green, Creamy Cleanser brand,
Formula 409 or Windex .

Wood Framing for AD Series


Quartz Sinks
Wall/
Studs Req.
Stud Stud @16 o.c. Species
Height
(See Note 1)

Grade

Stubborn Stains: Remove tough stains, with non abrasive cleaners and
pads such as a white Scotch Brite pad and Lysol. Special Situations for
Corian and Engineered Stone

10

2x4
2x6

3
1

12

2x4
2x6

3
1

Hard Water Deposits: Remove hard water deposits with a mild solution of
vinegar and water. Always rinse the unit thoroughly after cleaning.

14

2x4
2x6

3
1

Restoring the surface: Refresh and restore the rich surface with one of the
following:

16

2x4
2x6

3
2

18

2x4
2x6

3
2

20

2x4
2x6

3
2

SPF

No. 2

Note 1: Where mutiple studs are listed, bunch


multiple studs and space multiple studs @16
o.c. across width of sink

Geo Series: Color enhancer such as Tenax Ager


Pearl Series: Impregnating sealer such as DryTreat Stain - Proof Original
or Miracle Sealants 511 Impregnator Do not use strong acid or alkaline
chemicals and cleansers to clean Engineered Stone. If these chemicals come
in contact with the surface, wipe them off immediately and rinse with soapy
water. Avoid contact with harsh chemicals such as paint remover, bleach,
acetone, etc. Avoid contact with hot pans and objects.
Repair Kits: Corian repair kits are available. Contact your Sloan Stone Sink
Systems representative or distributor for part numbers and pricing. Repair
kits are made to order and have a shelf life of 30 days. Engineered Stone
shades of color can vary from product to product.

BRAND NAMES
Use of brand names is intended only to indicate a type of cleaner. This does
not constitute an endorsement, nor does the omission of any brand name
cleaner imply inadequacy. Many products named are regional in distribution,
and can be found in local supermarkets, department and hardware stores,
or through your cleaning service. It is emphasized that all products should be
used in strict accordance with package instructions.
REGULAR CLEANING OF DRAIN BOX REQUIRED.
DRAIN

GRID STRAINER

DRAIN BOX

4
FINISHED
WALL

3
ACCESS PANEL

FINISHED FLOOR

BOX

1. Lift access panel up by


pressing button(s) on
bottom of frame.
2. Swing outward until
panel separates frame.
3. Lift and separate from
frame.
4. Clean grid strainer
with rag and dispose
of properly.
5. Close access panel.

11

COMPONENTS SINGLE STATION


Sloan Optional
Water Temperature Mixing Valves

Deck
Optional
Not Provided
Chrome or
Plastic P-Trap

Grid Strainer
Assembly
DS-57

Mix-60-A

Mix-135-A

Rubber Gasket
Slip Washer
Flange Nut

Enclosure

Basys
Mid Faucet (EFX Series)

Basys
High Faucet (EFX Series)

Basys
Low Integrated Faucet (EFX Series)

Basys
Low Pedestal Faucet (EFX Series)

Basys
Hand Dryer

Basys
Soap Dispenser

Basys
Wall Mount Faucet (EFX Series)

COMPONENTS DOUBLE STATION


Sloan Optional
Water Temperature Mixing Valves
Optional
Not Provided
Chrome or
Plastic P-Trap

Deck
Grid Strainer
Assembly
DS-57

Mix-60-A

Mix-135-A

Rubber Gasket
Slip Washer
Flange Nut

Enclosure

Basys
Mid Faucet (EFX Series)

Basys
High Faucet (EFX Series)

Basys
Low Integrated Faucet (EFX Series)

Basys
Low Pedestal Faucet (EFX Series)

Basys
Hand Dryer

Basys
Soap Dispenser

Basys
Wall Mount Faucet (EFX Series)

COMPONENTS TRIPLE STATION


Sloan Optional
Water Temperature Mixing Valves
Deck
Grid Strainer
Assembly
DS-57

Optional
Not Provided
Chrome or
Plastic P-Trap

Mix-60-A

Mix-135-A

Rubber Gasket
Slip Washer
Flange Nut

Enclosure
Basys
High Faucet (EFX Series)

Basys
Mid Faucet (EFX Series)

Basys
Low Pedestal Faucet (EFX Series)

Basys
Soap Dispenser

Basys
Wall Mount Faucet (EFX Series)

Basys
Low Integrated Faucet (EFX Series)

Basys
Hand Dryer

COMPONENTS QUADRUPLE STATION


Sloan Optional
Water Temperature Mixing Valves
Grid Strainer
Assembly
DS-57

Deck

Optional
Not Provided
Chrome or
Plastic P-Trap

Mix-60-A

Mix-135-A

Rubber Gasket
Slip Washer
Flange Nut

Enclosure

Basys
High Faucet (EFX Series)

Basys
Low Integrated Faucet (EFX Series)

12

Basys
Mid Faucet (EFX Series)

Basys
Low Pedestal Faucet (EFX Series)

Basys
Wall Mount Faucet (EFX Series)

Basys
Hand Dryer

Basys
Soap Dispenser

Sloan Valve Company


10500 Seymour Avenue
Franklin Park, IL 60131
customer.service@sloanvalve.com
www.sloanvalve.com
Tel. 800.982.5839

The information contained in this document is subject to change without notice.


Copyright 2015 Sloan Valve Company
CODE NO. 0816672 Rev. 2 (07/15)

Vous aimerez peut-être aussi