Académique Documents
Professionnel Documents
Culture Documents
InstituteforHealthcareImprovement:FailureModesandEffectsAnalysisToolProcessDataReport
FailureModesandEffectsAnalysis(FMEA)Tool
CopyofSpecimentcollectionandReporting
PremierEndosocpyCenter
naples,Florida,UnitedStates
Other
Aim:Reducethisriskofspecimensandreportsbeinglost
ProcessData
Date:02/11/2010
Step
Description
Specimensareloggedonspecimensheet
FailureMode
Causes
Nurseforgetstolog
specimen
Humanerror,nursehasbusy Delayinprocessingresults
dayforgets
Specimenloggedonincorrect humanerror,distraction
labsheet
Step
Description
NaplesPathsendscouriertopickupspecimens
Effects
Specimengoestowronglab,
specimenlost
FailureMode
Causes
Effects
Courierdoesn'tshow
Caraccident,forgetsthis
stoponroute
Delayinprocessingspecimen
Step
Description
couriersignsforspecimens
FailureMode
Causes
courierforgetstosignand
specimenisleft
Humanerror,rushed,lackof Delayinprocessing
training,distraction
specimen.Iftimesensitive
specimencannotbe
processed
Step
Description
reportsaremailedtofacility
Effects
FailureMode
Causes
Effects
Noreportsmailedinthe
usualtimeframe
Erroratlab,lost
Delayoromissionin
reviewingspecimenreport
andtreatingpatient
Step
Description
receptionistplacesreportonpatientchart
10
Humanerror,lackoftraining, Delayintreatingpatient
distraction
receptionistplaceswrong
reportonpatientchart
distraction,humanerror,
similarpatientnames
10
Description
chartsgiventophysciantoreview
48 Specimenboxtobechecked
attheendoftheday.If
specimensleft,calllab
40 Checkforleftspecimensand
forinitialsofcourieratthe
endoftheday
Causes
100 Nursetoverifylabsheet
whenrecordingspecimen
Receptionistfailstoputthe
reportontheincomplete
chart
Potentialtreatmentofwrong
patientandomissionof
treatmentforcorrectpatient
30 Procedureroomcheckedat
endofdayforspecimens
FailureMode
Step
Effects
64 Reportsloggedinonlab
sheetandcheckeddailyfor
omissions
FailureMode
Causes
Effects
Physicianfailstoreviewthe
chart
Busyandforgets,human
error
Delayinreviewingreportand
delayintreatingpatient
10
50 Checkthatallreportsare
reviewedbyphysicianprior
toscanningdocuments
chartsgiventowrong
physician
humanerror,distraction
delayintreatmentofpatient,
breachofpatient
confidentiality
10
60 Verifycorrectphysician
roombeforeplacingreports
Step
Description
physicianreviewsreportandsigns
FailureMode
Causes
Effects
physiciandoesn'treviewor
forgetstosign
Busyday,inahurry,
distractions
Delayintreatingpatient
Step
Description
chartsarereturnedtobescanned
FailureMode
Causes
Effects
10
50 Checkallchartsfor
physician'ssignaturepriorto
placinginthecompleted
chartstobescanned
http://app.ihi.org/Workspace/tools/fmea/ProcessDetailDataReport.aspx?ToolId=10146&ScenarioId=11756&Type=1
1/2
9/14/2015
Physicianfailstoreturn
chartstocorrectshelf
InstituteforHealthcareImprovement:FailureModesandEffectsAnalysisToolProcessDataReport
Humanerror,distraction
Delayinscanningchart
20 Doctortogivecompleted
chartstoreceptionistto
placeoncorrectshelf
CalculatedTotals
TotalRiskPriorityNumberfortheprocess
602
Occ: LikelihoodofOccurrence(110)
Det: LikelihoodofDetection(110)
NOTE: 1=VerylikelyitWILLbedetected
10=VerylikelyitWILLNOTbedetected
Sev: Severity(110)
RPN:RiskPriorityNumber(OccDetSev)
Annotation
None
http://app.ihi.org/Workspace/tools/fmea/ProcessDetailDataReport.aspx?ToolId=10146&ScenarioId=11756&Type=1
2/2