Vous êtes sur la page 1sur 4

New Hydraulic LSHT Motor

High pressure
High performance
Customer satisfaction

Applications

More power and improved overall performance


are some of the advantages users of skid-steer
loaders with TMT have perceived. The source of
these advantages is the new 350 bar TMT
motor by Sauer-Danfoss, because it is particularly well suited for propulsion of vehicles with
indispensable requirements for large-scale
performance and surplus power in demanding
working situations.

Pressure level cont.: 250 bar, int.: 350 bar,


peak: 400 bar
New improved valving and balancing system
to give higher efficiencies at higher pressure
Stronger drive train to allow higher output
torque
Stronger bearings to allow higher radial
loads
Very suitable for operation in series
Sturdy and compact design
The wide displacement range variates from
250 ccm to 630 ccm
High efficiency lowers the demands on the
pump and leads to a generally lower
requirement for engine power.

Highlights

The lower demand for engine power releases


power for other machine purposes
Environmental impact. The lower requirement for engine power entails a smaller
fuel consumption and reduced emission.
Possible emission restrictions on off-highway
equipment will increase the attention on
engine power requirements and engine
fuel consumption
Higher efficiency leads to smaller components in the hydraulics system.

Technical data for TMT


Motor type
Motor size

TMT

TMT

TMT

TMT

TMT

TMT

250

315

400

470

500

630

Geometric displacement

cm

251,8

326,3

410,9

477,3

523,6

629,3

Max. speed

(r/min)

cont.
int. 1)

500
600

380
460

305
365

270
320

240
285

200
240

Max. torque 4)

(Nm)

cont.
int. 1)
peak 2)

900
1280
1440

1165
1635
1865

1470
2060
2355

1710
2390
2735

1875
2250
2620

1805
2345
2708

Max. output

(kW)

cont.
int. 1)

41
70

41
70

41
70

41
70

41
59

33
51

Max. pressure drop 4)

(bar)

cont.
int.
peak 2)

250
350
400

250
350
400

250
350
400

250
350
400

250
300
350

200
260
300

Max. flow

(l/min)

cont.
int. 1)

125
150

125
150

125
150

125
150

125
150

125
150

Max. inlet pressure

(bar)

cont.
int.
peak

270
370
420

270
370
420

270
370
420

270
370
420

270
370
420

270
370
420

Max.starting pressure
with unloaded shaft

(bar)

Min. starting torque

(Nm)

750
1050

970
1355

1225
1715

1420
1985

1555
1865

1505
1950

Min. speed 3)

(r/min)

max. cont.
max. int. 1)

Vetterli & Hjortshj A/S Advertising/Marketing DKMH.PB.141.B1.02/520L0309 2000/09

1) Intermittent operation: permissible values may occur for max. 10% of every minute.
2) Peak load: permissible values may occur for max. 1% of every minute.
3) With speeds lower than stated, smooth running cannot be expected.
4) The values stated apply to hydrostatic propulsion applications. In other applications the values for pressure and torque should be multiplied by 0.9.
For forestry processors max. torque corresponds to the value for OMT.

Sauer-Danfoss can accept no responsibility for possible errors in


catalogues, brochures and other printed or electronic material.
Sauer-Danfoss reserves the right to alter its products without
prior notice. This also applies to products already ordered provided that such alterations can be made without subsequent
changes being necessary in specifications already agreed.
All trademarks in this material are properties of the respective
companies. Sauer-Danfoss and the Sauer-Danfoss logotype are
trademarks of the Sauer-Danfoss Group. All right reserved.

www.sauer-danfoss.com

Vous aimerez peut-être aussi