Académique Documents
Professionnel Documents
Culture Documents
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Engineer 360
Collin
|
Page:
Project:
Fastening Point:
Date:
1
8/12/2015
Specifier's comments:
1 Input data
Anchor type and size:
Material:
5.8
Approval No.:
ETA 04/0027
Issued I Valid:
6/26/2013 | 5/16/2018
Proof:
Design method SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation:
eb = 0 mm (no stand-off); t = 25 mm
Baseplate:
Profile:
Base material:
uncracked concrete, C35/45, fc = 35.00 N/mm2; h = 500 mm, Temp. short/long: 30/30 C
Installation:
Reinforcement:
No reinforcement or Reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
8/12/2015
Shear force y
0.000
0.000
0.000
0.000
0.000
0.000
3
Tension
4
x
Compression
Capacity [kN]
74.667
Utilisation bN [%]
101
Status
not recommended
225.399
59.212
381
not recommended
225.399
60.811
371
not recommended
Splitting failure**
225.399
120.633
187
not recommended
Steel failure*
gM,s
1.500
NRd,s [kN]
74.667
NSd [kN]
75.133
A0p,N [mm2]
256000
yA,Np
1.058
2
tRk,ucr,25 [N/mm ]
12.00
scr,Np [mm]
506
yc
1.061
2
tRk,ucr [N/mm ]
12.73
yg,Np
1.062
yg,Np
1.027
ec1,N [mm]
0
yec1,Np
1.000
ec2,N [mm]
0
yec2,Np
1.000
ys,Np
0.842
N0Rk,p [kN]
135.937
NRk,p [kN]
124.345
gM,p
2.100
NRd,p [kN]
59.212
NSd [kN]
225.399
ccr,Np [mm]
253
cmin [mm]
120
yre,Np
1.000
A0c,N [mm2]
260100
yA,N
1.052
ccr,N [mm]
255
scr,N [mm]
510
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
0
yec2,N
1.000
ys,N
0.841
yre,N
1.000
N0Rk,c [kN]
144.245
gM,c
2.100
NRd,c [kN]
60.811
NSd [kN]
225.399
Ac,N [mm2]
162400
A0c,N [mm2]
115600
yA,N
1.405
ccr,sp [mm]
170
scr,sp [mm]
340
yh,sp
1.371
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
0
yec2,N
1.000
ys,N
0.912
yre,N
1.000
N0Rk,c [kN]
144.245
gM,sp
2.100
NRd,sp [kN]
120.633
NSd [kN]
225.399
k1
11.000
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
k1
11.000
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
8/12/2015
Capacity [kN]
37.333
Utilisation bV [%]
10
Status
OK
N/A
N/A
N/A
N/A
Pryout failure**
21.000
208.865
11
OK
10.500
40.999
26
OK
gM,s
1.500
VRd,s [kN]
37.333
VSd [kN]
3.500
A0c,N [mm2]
260100
yA,N
1.291
ccr,N [mm]
255
scr,N [mm]
510
k4
2.000
ec1,V [mm]
0
yec1,N
1.000
ec2,V [mm]
0
yec2,N
1.000
ys,N
0.841
yre,N
1.000
N0Rk,c [kN]
144.245
gM,c,p
1.500
VRd,c1 [kN]
208.865
VSd [kN]
21.000
dnom [mm]
20.0
kV
2.400
a
0.119
c1 [mm]
120
Ac,V [mm2]
104400
A0c,V [mm2]
64800
yA,V
1.611
ys,V
1.000
yh,V
1.000
ya,V
1.000
ec,V [mm]
0
V0Rk,c [kN]
38.172
gM,c
1.500
VRd,c [kN]
40.999
VSd [kN]
10.500
b
0.070
yec,V
1.000
yre,V
1.000
y90,V
2.500
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
steel
concrete
a
bN
a
bV
bN
1.006
bV
0.094
a
2.000
Status
not recommended
3.807
0.256
1.500
756
not recommended
<= 1
55.654 [kN]
VSk
2.593 [kN]
dN
0.469 [mm]
dV
0.104 [mm]
dNV
0.480 [mm]
55.654 [kN]
dN
0.938 [mm]
VSk
2.593 [kN]
dV
0.156 [mm]
dNV
0.951 [mm]
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Engineer 360
Collin
|
Page:
Project:
Fastening Point:
Date:
4
8/12/2015
7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can
be
achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Characteristic bond resistances depend on short- and long-term temperatures.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
8/12/2015
8 Installation data
Baseplate, steel: Profile: I profile; 203 x 133 x 11 x 11 mm
Hole diameter in the fixture: df = 22 mm
Plate thickness (input): 25 mm
Recommended plate thickness: not calculated
Cleaning: Premium cleaning of the drilled hole is required
Drilling
Suitable Rotary Hammer
Properly sized drill bit
150
40
150
Setting
Dispenser including cassette and mixer
Dynamic set
Torque wrench
110
150
40
150
110
40
220
40
x
-110
110
-110
y
-110
-110
0
c-x
120
340
120
c+x
340
120
340
c-y
-
c+y
-
Anchor
4
5
6
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
x
110
-110
110
y
0
110
110
c-x
340
120
340
c+x
120
340
120
c-y
-
c+y
-
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Engineer 360
Collin
|
Page:
Project:
Fastening Point:
Date:
6
8/12/2015
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan