Académique Documents
Professionnel Documents
Culture Documents
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Engineer 360
Collin
|
Page:
Project:
Fastening Point:
Date:
1
8/28/2015
Specifier's comments:
1 Input data
Anchor type and size:
Material:
B500B
Approval No.:
ETA 04/0027
Issued I Valid:
6/26/2013 | 5/16/2018
Proof:
Design method SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation:
eb = 0 mm (no stand-off); t = 25 mm
Baseplate:
Profile:
Base material:
uncracked concrete, C35/45, fc = 35.00 N/mm2; h = 500 mm, Temp. short/long: 30/30 C
Installation:
Reinforcement:
No reinforcement or Reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
|
8/28/2015
Utilisation
Loading
Tension
Proof
Concrete cone failure
Load
74.585
Capacity
78.120
bN / bV [%]
96 / -
Status
OK
Shear
3.067
18.785
- / 17
OK
bV
0.163
a
1.5
Status
OK
Loading
Combined tension and shear loads
bN
0.955
3 Warnings
Please consider all details and hints/warnings given in the detailed report!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan