Application
TestingbondingbetweenBabbittmetalbearinglinersandsteelorbronzebearingshells,alsomeasurementoflinerthickness.

Background
Babbittmetal,firstformulatedin1839,isanalloyoftinorlead,copper,andantimonythatiscommonlyusedasarollingcontactsurfaceinfrictionbearingsbecauseofitslow
coefficientoffriction,goodloadbearingandlubricationproperties,andresistancetogalling.BabbittbearingstypicallyconsistofarelativelythinlayerofBabbittcastovera
steelorbronzeshellthatprovidesstructuralstrength.ProperbondingbetweentheBabbittlinerandthesteelorbronzeshellisessentialforperformance,andthethicknessof
theBabbittisoftenofinterestaswell.BabbittbondingandthicknesscanbereadilytestedwithultrasonicflawdetectorsaslongastheBabbittlayerthicknessisgreaterthan
approximately0.008or0.2mm.

Equipment
AnyOlympusflawdetectorcanbeusedforthistest.TheseincludetheEPOCH600,EPOCH1000,EPOCHLTC,andEPOCH650.Selectedcontactordelaylinetransducers
willbeusedasdescribedbelow.

Procedure
(a)Bondtestfromoutersurfaceofbearing
IncaseswheretheoutersurfaceofthebearingshellisaccessibleandconcentricwiththeID,thesimplestprocedureistotestfromtheoutsidewithasmallcontacttransducer,
typicallyinthefrequencyrangefrom10MHzto2.25MHz.CommonchoicesincludetheV112RM(10MHz),V110RM(5MHz),andV106RM(2.25MHz).Ifthelineris
bonded,asmallechofromtheshell/linerboundarywillbefollowedbyalargerechofromthelinerID.Ifthelinerisdisbonded,therewillbeonlyalargeechofromtheinner
surfaceoftheshell.
Thewaveformsbelowshowatypicalresponsefroma0.080(2mm)Babbittlinerinsidea0.700(17.75mm)steelshell,usingaV112RMcontacttransducer.Inthewaveform
atleft,thesmallnegativeechointheredgatefollowedbyanechointhebluegaterepresentsabondedcondition.Inthewaveformatright,themuchlargernegativeechoin
theredgateandanabsenceofanechointhebluegaterepresentsadisbond.

data:text/htmlcharset=utf8,%3Ch2%20style%3D%22boxsizing%3A%20borderbox%3B%20fontfamily%3A%20Arial%2C%20Helvetica%2C%20sansserif%3B%20fontweight%3A%20normal%3B%20lineheig

1/4

17/11/2015

UltrasonicInspectionofBabbittBearingLiners

Typicalwaveformfrombond
Typicalwaveformfromdisbond
(b)Bondtestingfrominnersurfaceofbearing
LinerbondingcanalsobetestedfromtheIDusingasmalldiameterdelaylinetransducer,typicallywithabroadbanddelaylinethathasbeenradiusedtoconformtotheID
curvatureforoptimumcoupling.Frequencyrangesfrom20MHzforverythinBabbitt(under0.020or0.5mm)to2.25MHzforthickBabbit(0.200or5mmandgreater).
CommonchoicesincludetheV208RM(20MHz),V202RM(10MHz),V206RB(5MHz),andV207RB(2.25MHz)withradiuseddelaylines.Thistestisbasedonbothecho
phaseandamplitude.IftheBabbittisbonded,therewillbeapositivepolarityreflectionfromtheliner/shellboundary.IftheBabbittisdisbonded,theechowillbenegativeand
significantlylarger.Thisisduetotherelativeacousticimpedancesofthetwometals.Thewaveformsbelowshowatypicalresponsefroma0.080(2mm)Babbittlinerinsidea
steelshell,usingaV202RMdelaylinetransducer.Inthewaveformatleft,thesmallpositiveechointhegaterepresentsabondedcondition.Inthewaveformatright,themuch
largernegativeechofollowedbyamultiplereflectionrepresentsadisbond.

data:text/htmlcharset=utf8,%3Ch2%20style%3D%22boxsizing%3A%20borderbox%3B%20fontfamily%3A%20Arial%2C%20Helvetica%2C%20sansserif%3B%20fontweight%3A%20normal%3B%20lineheig

2/4

17/11/2015

UltrasonicInspectionofBabbittBearingLiners

Typicalwaveformfrombond
Typicalwaveformfromdisbond
(c)Babbittthicknessmeasurement
Whethertestingfromtheoutsideorinside,Babbittthicknessismeasuredinechotoechomodebetweenthetwopeaksrepresentingtheshell/linerbondlineandtheID
reflection.Thicknessmeasurementusesthesametransducersasthebondingtestandcanbeperformedsimultaneously.Thewaveformbelowshowsatypicalechotoecho
thicknessmeasurementfromtheIDofabearing.NotethatBabbittmetalisverysoftandthushasveryslowsoundvelocityforametal,typicallyabout.1315in/usor3350m/sfor
tinbasedBabbittalloysandabout.0900in/usor2285m/sforleadbasedBabbitt.

data:text/htmlcharset=utf8,%3Ch2%20style%3D%22boxsizing%3A%20borderbox%3B%20fontfamily%3A%20Arial%2C%20Helvetica%2C%20sansserif%3B%20fontweight%3A%20normal%3B%20lineheig

3/4

17/11/2015

UltrasonicInspectionofBabbittBearingLiners

Babbittthicknessmeasurement
ForfurtherinformationonBabbittbearingtestingoranyotherultrasonictestapplications,contactOlympus.

data:text/htmlcharset=utf8,%3Ch2%20style%3D%22boxsizing%3A%20borderbox%3B%20fontfamily%3A%20Arial%2C%20Helvetica%2C%20sansserif%3B%20fontweight%3A%20normal%3B%20lineheig

4/4

Vous aimerez peut-être aussi